Z7A. Load cells. Special features. Data sheet. Wiring code
|
|
- Hubert Webster
- 5 years ago
- Views:
Transcription
1 Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg t - Fulfills EMC requirements in accordance to EN Low transducer height - Robust design Data sheet Wiring code 6 wire circuit (gray) (black) Sense (-) Excitation (-) (white) Signal (+) (blue) (green) Excitation (+) Sense (+) (red) Signal (-) (-) Shield / wire strand connected with housing
2 Dimensions Z7A (in mm, 1mm = inches) øl Cable: 6 cores, screened m long H K2 N øm A D F G E K1 C B J Nominal load in t L +0.2 M H11 J B H N A D F G E C K1 K2 M* in N m 0.5 and * Tightening torque with screws of property class 10.9 (with μ=0.16). Accessories, to be ordered sparately: rubber metal bearing ZEL Pendulum bearing ZPL HBM 2
3 Specifications Type Accuracy class according to OIML R 60 Max. number of load cell verification intervals (n LC ) D Z7A C Max. capacity (E max ) t 0.5; 1; 2; 5; 10 2; 5; 10 Min. load cell verification interval (v min ) % of E max Sensitivity (C n ) mv/v 2 Sensitivity tolerance % Temperature effect on sensitivity (TK C ) 1) % of C n /10 K Temperature effect on zero signal (TK 0 ) Hysteresis error (d hy ) 1) Non linearity (d lin ) 1) Creep (d cr ) in 30 min. % of C n Input resistance (R LC ) at reference temperature 350 Ω Output resistance (R O ) at reference temperature Nominal rang of excitation voltage (U ref ) Maximum excitation voltage (B U ) Reference temperature Nominal temperature range (B T ) Operating temperature range (B tu ) Storage temperature range (B tl ) Save load limit (E L ) Breaking load (E d ) V [+73.4] [ ] C [ F] [ ] [ ] 150 % of E max 300 Max. capacity (E max ) t Relative static lateral force limit (E lq ) 2) (100) 2) (100) 2) (100) 2) Permissible dynamic load (F srel ) (vibration amplitude according to DIN 50100) % of E max 70 Nominal displacement (s nom ), approx. Weight (G), approx. Degree of protection according to EN60529 (IEC529) IP 67 Material Measuring body Cable gland Cable sheath mm kg Steel, galvanized Stainless steel / Viton PVC 1) The values stated for the non linearity, the hysteresis and the temperature coefficient of sensitivity are standard values. The sum of these values is within the accumulated error limit according to OIML R60. 2) The values given in parentheses refer to installation with stops preventing the transducer base from moving. In this case, major error effects have to be anticipated Options Ex protection versions as per IECEx and ATEX AI1/21 IECEx+ATEX zone 1/21 + FM intrinsically safe, II 2G Ex ia IIC T6/T4 Gb, II 2D Ex ia IIIC T125 C Db* AI2/22 IECEx+ATEX Zone 2/22 non-intrinsically safe, II 3G Ex na IIC T6/T4 Gc, II 3D Ex tc IIIC T125 C Dc* * with EU type examination certificate (BVS13ATEX E 108 X) and IECEx Certificate of Conformity (IECEx BVS X) 3 HBM
4 Mounting aids ( Dimensions in mm; 1mm = inches ) Rubber metal bearing ZEL R Z X e B ZEL a Y T L P Max. capacity in t Rubber metal bearing ZEL B L P R T X Y Z a e F R * (N) Z17/2t/ZEL ,5 1,7 5 Z17/5t/ZEL ,2 2,0 10 HLCB/10t/ZEL ,8 2,0 s max ** (mm) * F R =restoring force for s=1mm. ** s max =max. lateral displacement of load introduction with max. capacity. Pendulum bearing ZPL F 1 T jc 1 M E ju jo D 1 ZPL maximum inclination of 3 H 2 dust proof protection rings and a fixing screw included with ZPL jc Max. capacity in t Pendulum bearing ZPL C +0.2 C D 1 E F 1 H M O T U D10 h9 F R * (% of load) Z17/2t/ZPL M Z17/5t/ZPL M Z17/10t/ZPL M * F R =restoring force for s=1mm. ** s max =max. lateral displacement of load introduction with nominal load. s max ** (mm) HBM 4
5 Z7A load cells, optional versions Order number K Z7A Code S Option 1: Mechanical design Standard Code Option 2: Accuracy class D1 D1 (OIML) C3 C3 (OIML) [only with Option 3 = 2 / 5 / 10] Code Option 3: Nennlast kg [only with Option 2 = D1] 1 1 t [only with Option 2 = D1] 2 2 t 5 5 t t Code Option 4: Explosion protection N No expolsion protection AI1/21 IECEx + ATEX zone 1/21 and FM AI2/22 IECEx + ATEX zone 2/22 Code Option 5: Cable length S 6 m (standard) m Code N Option 6: Other Standard K-Z/A - S N 5 HBM
6 Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 6 Hottinger Baldwin Messtechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax info@hbm.com
Single point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationLoad cell. Special features. Data sheet
Z6 Load cell Special features - Welded on metal bellows - (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 divisions, test report as per
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationRing-Torsion Load Cells RTB
Ring-Torsion Load Cells RTB % PTB & OIML approved as suitable for trade use (up to 6000 d and 7500 d in case of multi-divisional scales) % High accuracy, even for very small utilisation ranges (down to
More informationTOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en
TOP Transfer Force transfer standard Data Sheet Special characteristics Ultimate precision force transducer for international comparative measurements Tensile/compressive force transducer Nominal forces
More informationTOP Transfer. Data sheet. Force transfer standard. Special features. B en
TOP Transfer Force transfer standard Data sheet Special features - Force transducer with ultimate precision for international comparison measurements - Tensile/compressive force transducer - Nominal forces
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationTB2. Data Sheet. Torque reference transducer. Special features. B en
T2 Torque reference transducer Data heet pecial features tandard version ptional: rotection I67 - ccuracy class 0.03 - s 100 m, 200 m, 500 m, 1 k m, 2 k m, 3 k m, 5 k m and 10 k m - High permissible oscillation
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationBenefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments
Data sheet Force transducer Series RF-I (160 kn 4000 kn) Benefits/Application Accuracy class 0,05 For static and dynamic tensile and compressive forces Very high-cycle fatigue resistant up to 100 of nominal
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationBSD MODULFLEX R Torsionally Rigid Couplings
BSD MODULFLEX R Torsionally Rigid Couplings for T1F Torque Flange View B Thread opening turned in sectionel plane b b 6 b 7 b 2 b 8 b 3 b za View A A B NVm 1 NVm View A btot Reference dimension X X 2 NVm
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationBenefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories
D a t a s h e e t T o r q u e T r a n s d u c e r S e r i e s M ( 2 N m 1 0 0 0 0 N m ) Benefits/Application For static and dynamic moments Non-rotational construction Very high-cycle fatigue resistant
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationBenefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories
D a t a s h e e t F o r c e T r a n s d u c e r S e r i e s R F ( 2 5 k N 0 M N ) Benefits/Application For static and dynamic tensile and compressive forces Outstanding overload-tolerance Very high-cycle
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationD a t a s h e e t. F o r c e T r a n s d u c e r. S e r i e s K. ( 4 k N k N ) Benefits/Application. Options/Accessories
D a t a s h e e t F o r c e T r a n s d u c e r S e r i e s K ( k N 6 3 0 k N ) Benefits/Application For static and dynamic tensile and compressive forces Hermetically sealed Very small force application
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationField mounted Temperature Transmitter TF212/TF212-Ex
Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote
More informationANNEX to IECEx Certificate
ANNEX to IECEx Certificate Certificate No.: IECEx ZLM 11.0001X Issue No.: 0 Date of Issue: 2011-09-14 Type designation code EDP300 xx * * * * * ** ** ** ** xx ** ** ** ** ** ** ** ** Limit Switches: without,
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationExchangeable measuring insets SensyTemp TSA101
Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationD a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories
D a t a s h e e t T o r q u e s t a n d a r d S e r i e s D m - T N ( 1 N m 0 0 0 0 N m ) Benefits/Application Class VN (better class 0,05 acc. DIN 51309) For highest precision requirements Easy adaption
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More information1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration
1551A Ex/155A Ex Intrinsically Safe Stik Thermometer The new gold standard of industrial temperature calibration Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers!
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation
TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSA101 Exchangeable measuring insets 2 SENSYTEMP TSA101 EXCHANGEABLE MEASURING INSETS DS/TSA101-EN REV. E Measurement made easy Compatible
More informationInstallation Equipment
Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester
More informationEx floating switches and Ex immersion probes
Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationDimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial
Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationStrain Gauges and Accessories
Strain Gauges and Accessories Nurgül Er nurguel.er@hbm.com www.hbm.com 19.03.2008, Folie 1 Hottinger Baldwin Messtechnik GmbH Nurgül Er How to find the right strain gauge a wide range of of strain gauges
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationTH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation
TH 0 / TH 0-Ex Field mounted temperature transmitter, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation 0/-8.6 EN Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationDesigned to go where you work
Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers! Accurate and repeatable to ± 0.05 C over its full range, the 55A/55A Stik Thermometer is the new gold
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More informationINVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
IMEKO 23 rd TC3, 13 th TC5 and 4 th TC22 International Conference 30 May to 1 June, 2017, Helsinki, Finland INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE
More informationT e c h n i c a l L e x i c o n
T e c h n i c a l L e x i c o n T e r m s f r o m F o r c e a n d t o r q u e m e a s u r e m e n t t e c h n o l o g y a n d G T M d a t a s h e e t s Technisches Lexikon (eng.) 16/10/14 Introduction
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationIncreased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them
B 3.1 Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them Dr. Schäfer, André Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45, 64293 Darmstadt andre.schaefer@hbm.com
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationA compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen.
Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationWind Speed & Direction Sensors
Wind Speed & Direction Sensors gillinstruments.com Gill Instruments has over twenty-five years experience in air flow measurement using ultrasonic technology and is a world leader in the field of wind
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationTÜV NORD CERT GmbH Am TÜV 1 30519 Hannover IECEx Certification Body Page 1 of 3 Issue No. 2 of IECEx TUN 06.0014 X IECEx TR: File reference: DE/TUN/ExTR06.0059/02 07 203 554192 IECEx QAR: DE/QAR/TUN/06.0002/00
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationCapacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z
Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts
More informationLoad Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B
Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100
More informationHR-Z SERIES Mild Radiation Resistance LVDT
SERIES Mild Radiation Resistance LVDT SPECIFICATIONS Mild Radiation Resistant High Reliability Large core-to-bore clearance Stroke ranges from ± 0.05 to ±10 inches AC operation from 400Hz to 5kHz Stainless
More information