Pressure Measurement Single-range transmitters for general applications

Size: px
Start display at page:

Download "Pressure Measurement Single-range transmitters for general applications"

Transcription

1 Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement with cap made of PPE (left), stainless steel (mid) and ETFE (right). The pressure transmitter measures the liquid levels in tanks, containers, channels and dams. The SITRANS LH00 pressure transmitters are available for various measuring ranges and with explosion protection as an option. A junction box and a cable hanger are available as accessories for simple installation. Benefits Compact design Simple installation Small error in measurement (0. % typical) Degree of protection IP68 Application SITRANS LH00 pressure transmitters are used in the following branches, for example: Shipbuilding Water/waste water supply Drinking water facilities For use in unpressurized/open vessels and wells Desalination plants Design The pressure transmitter has a built-in ceramic sensor which is equipped with a Wheatstone resistance bridge. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. In addition, the connecting cable contains a vent pipe which is equipped with a humidity filter to prevent the build-up of condensation. The diaphragm is protected against external influences by a protective cap. The sensor, the electronics and the connecting cable are housed in an enclosure with small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. SITRANS LH00 pressure transmitter, mode of operation and connection diagram On one side of the sensor (), the diaphragm () is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe () in the connecting cable. The vent pipe is equipped with a humidity filter which prevents the build-up of condensation in the vent pipe. The hydrostatic pressure of the liquid column acts on the diaphragm of the sensor and transmits the pressure to the Wheatstone resistance bridge in the sensor. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of to 0 ma. The protective conductor connection/equipotential bonding () is connected to the enclosure. Integration It is generally recommended that the connecting cable of the SITRANS LH00 transmitter is connected to the junction box, which can be ordered separately, and secured with the cable hanger, also available separately. The junction box has to be installed near the measuring point, but outside the media. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter, cable and gasket. To measuredvalue processing Venting pipe Junction box 7MF7-8AA, open, schematic diagram To transmitter 7MF7 Siemens FI 0 News January 07

2 Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Measuring point setup, generally with junction box 7MF7-8AA and 7MF7-8AB cable hanger Technical specifications SITRANS LH00 (submersible sensor) Mode of operation Measuring principle Piezo-resistive Input Measured variable Hydrostatic level Measuring range Max. permissible operating pressure 0... mh O (0... fth O). bar (.8 psi) (corresponds to mh O ( fth O)) 0... mh O ( fth O). bar (.8 psi) (corresponds to mh O ( fth O)) 0... mh O ( fth O). bar (.8 psi) (corresponds to mh O ( fth O)) 0... mh O (0... fth O) bar (9 psi) (corresponds to 0 mh O (60 fth O)) 0... mh O (0... fth O) bar (9 psi) (corresponds to 0 mh O (60 fth O)) mh O ( fth O) bar (9 psi) (corresponds to 0 mh O (60 fth O)) mh O ( fth O) bar (7. psi) (corresponds to 0 mho (0 fth O)) mh O ( fth O) 0 bar ( psi) (corresponds to 00 mh O (00 fth O)) mh O ( fth O) 0 bar (90 psi) (corresponds to 00 mh O (600 fth O)) Special measuring ranges Up to 00 mh O (00 fth O) 0 bar (90 psi) (corresponds to 00 mh O (600 fth O)) Up to 60 mh O (80 fth O) bar (8 psi) (corresponds to 0 mh O (70 fth O)) Measuring range bar.bar bar.bar bar.bar bar bar bar bar bar bar 0... bar bar 0... bar 0bar 0... bar 0bar Special measuring range Up to 0 bar 0bar Up to 6 bar bar Output Output signal...0 ma Measuring accuracy According to IEC Error in measurement at limit setting 0. % of full-scale value (typical) including hysteresis and reproducibility 0. % of full-scale value (maximum) Influence of ambient temperature 0.0 %/0 K of full-scale value (zero and span) Long-term stability 0. % of full-scale value/year (zero and span) Rated conditions Ambient conditions Process temperature C ( F) Storage temperature C ( F) Degree of protection according to IP68 IEC 609 Siemens FI 0 News January 07

3 Siemens AG 07 Design Weight 0. kg ( 0.88 lb) Cable 0.08 kg/m ( 0.09 lb/ft) Electrical connection Cable with conductors, vent pipe and integrated humidity filter Material Seal diaphragm Al O ceramic, 99.6 % Enclosure Stainless steel, mat. no..0/6l and.9/90l (sea water applications) respectively Gasket FPM (standard) EPDM (optional) Connecting cable PE (standard/drinking water applications) FEP (for aggressive media) Cap Stainless steel, PPE or ETFE Auxiliary power Terminal voltage on pressure transmitter U B V DC for transmitter with 0... V DC intrinsic safety explosion protection Certificates and approvals Drinking water approval (ACS) Pending Drinking water approval (WRAS) Pending Drinking water approval (DVGW/ Pending KTW W70) EAC/EAC-Ex TC RU C-DE.ГБ0.В.008 OC НАНИО «ЦСВЭ» Underwriters Laboratories (UL) Pending Shipbuilding approval (LR) Pending Shipbuilding approval (DNV/GL) Pending Shipbuilding approval (BV) Pending Shipbuilding approval (ABS) Pending Pressure equipment directive The transmitter is not subject to the pressure equipment directive (PED 0/68/EU) Explosion protection IEC Ex ATEX EAC Ex SEV 6 ATEX 0 IEC Ex SEV Intrinsic safety "i" Marking II G Ex ia IIC T Ga SITRANS LH00 Transmitter for hydrostatic level Junction box Application Design Weight Electrical connection Cable entry Enclosure material Vent pipe for atmospheric pressure Screw for cable strength cord Rated conditions Degree of protection according to IEC 609 Cable hanger Application Design Weight Material For connecting the transmitter cable 0. kg (0. lb) x -way (8 to 8 AWG) x M0x. Polycarbonate IP6 For mounting the transmitter 0.6 kg (0. lb) Galvanized steel, polyamide Siemens FI 0 News January 07

4 Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Selection and ordering data Article Order No. code SITRANS LH00 (submersible sensor) For hydrostatic level measurement, 7 M F 7 - submersible transmitter, two-wire connection, 0 ma, body material see Order option, measuring cell Al O ceramics (99.6 % purity), with fixed mounted cable, material of protective cap at PE cable: PPE (colour black) material of protective cap at FEP cable: PPE (colour white) Note: junction box and cable hanger have to be ordered separately. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring range Cable length 0...mH O m } A 0... mh O m } B 0...mH O 0 m } C 0... mh O 0 m } D 0... mh O 0 m } E mh O 0 m } F mh O 0 m } H mh O 0 m } K mh O 0 m } L 0...ftH O m ( ft) A 0...6ftH O m ( ft) B 0...9ftH O 0 m ( 0 ft) C 0... fth O 0 m ( 0 ft) D 0... fth O 0 m ( 0 ft) E fth O 0 m ( 0 ft) F fth O 0 m ( 60 ft) H fth O 0 m ( 90 ft) K fth O 0 m ( 0 ft) L bar m A bar m B bar 0 m C bar 0 m D bar 0 m E bar 0 m F 0... bar 0 m H 0... bar 0 m K 0... bar 0 m L Special versions: Measuring ranges for special versions between 0... mh O and mh O or 0... fth O and fth O or bar and bar possible. Selection and ordering data SITRANS LH00 (submersible sensor) Article No. Order code 7 M F 7 - PE cable for general purpose and drinking water applications Special cable length Order code and plain text: Y0: Cable length... 9 X H.. Y 0 m ( 0 ft) H A m ( 6 ft) H B 7 m ( ft) H C 0 m ( ft) H D m ( 0ft) H E 0 m ( 6 ft) H F m ( 80 ft) H G 0 m ( 00 ft) H H 0 m ( 0 ft) H J 0 m ( 60 ft) H K 60 m ( 00 ft) H L 70 m ( 0 ft) H M 80 m ( 6 ft) H N 90 m ( 9 ft) H P 00 m ( 0 ft) H Q m ( 0 ft) H R 0 m ( 9 ft) H S 7 m ( 7 ft) H T 00 m ( 60 ft) H U m ( 70 ft) H V 0 m ( 80 ft) H W 7 m ( 900 ft) H X 00 m ( 990 ft) H A 0 m ( 0 ft) H B 00 m ( 0 ft) H C 0 m ( 80 ft) H D 00 m ( 60 ft) H E 0 m ( 8 ft) H F 600 m ( 980 ft) H G 60 m ( ft) H H 700 m ( 0 ft) H J 70 m ( 7 ft) H K 800 m ( 60 ft) H L 80 m ( 800 ft) H M 900 m ( 970 ft) H N 90 m ( ft) H P 000 m ( 00 ft) H Q Other special cable length Order codes and plain text: HY: Cable length... Y0: Measuring range... 9 X H Y Y 0 Siemens FI 0 News January 07

5 Siemens AG 07 Selection and ordering data Article No. Order code SITRANS LH00 (submersible sensor) 7 M F 7 - FEP cable for aggressive media Special cable length Order code and plain text: 9 X H.. Y 0 Y0: Cable length... m ( 0 ft) H A m ( 6 ft) H B 7 m ( ft) H C 0 m ( ft) H D m ( 0ft) H E 0 m ( 6 ft) H F m ( 80 ft) H G 0 m ( 00 ft) H H 0 m ( 0 ft) H J 0 m ( 60 ft) H K 60 m ( 00 ft) H L 70 m ( 0 ft) H M 80 m ( 6 ft) H N 90 m ( 9 ft) H P 00 m ( 0 ft) H Q m ( 0 ft) H R 0 m ( 9 ft) H S 7 m ( 7 ft) H T 00 m ( 60 ft) H U m ( 70 ft) H V 0 m ( 80 ft) H W 7 m ( 900 ft) H X 00 m ( 990 ft) H 6 A 0 m ( 0 ft) H 6 B 00 m ( 0 ft) H 6 C 0 m ( 80 ft) H 6 D 00 m ( 60 ft) H 6 E 0 m ( 8 ft) H 6 F 600 m ( 980 ft) H 6 G 60 m ( ft) H 6 H 700 m ( 0 ft) H 6 J 70 m ( 7 ft) H 6 K 800 m ( 60 ft) H 6 L 80 m ( 800 ft) H 6 M 900 m ( 970 ft) H 6 N 90 m ( ft) H 6 P 000 m ( 00 ft) H 6 Q Other special cable length Order codes and plain text: HY: Cable length... Y0: Measuring range... 9 X H Y Y 0 SITRANS LH00 Transmitter for hydrostatic level Selection and ordering data SITRANS LH00 (submersible sensor) Material of housing Stainless steel 6L (.0) Stainless steel 6L (.0) Stainless steel 6L (.0) Stainless steel 90L (.9) for sea water applications Material of protective cap Protective cap PPE (standard with PE cable) Protective cap ETFE (standard with FEP cable) Stainless steel 6L (.0) Protective cap PPE Article No. Order code 7 M F 7 - } A Stainless steel 90L Protective cap ETFE E (.9) for sea water applications Stainless steel 90L Stainless steel 90L F (.9) for seawater (.9) for seawater applications applications Sealing material between sensor and housing FPM (Standard) } EPDM (for drinking water) Explosion protection without } 0 With ATEX II G Ex ia IIC T Ga and } IECEx Ex ia IIC T Ga (only possible for cable length 00 m (990 ft) Additional versions Order code Quality Inspection Certificate (factory calibration) C to IEC Accessories/spare parts Article No. Junction box } 7MF7-8AA Cable hanger } 7MF7-8AB Protective caps, PPE, as spare part } 7MF7-8AD (0-pack) Protective caps, ETFE, as spare part } 7MF7-8AE (0-pack) Humidity filters as spare part } 7MF7-8AF (0-pack) Protective cap, stainless steel 6L } 7MF7-8AG (.0) for waste water applications Protective cap, stainless steel 90L } 7MF7-8AH (.9) for sea water applications } Available ex stock We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/ in the appendix. B C D Siemens FI 0 News January 07

6 Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Dimensional drawings Sensor with protective cap (PPE, ETFE) ~6 (6.) 9 (0.7) Ø0 (.8) Ø0 (.8) 0. (0.) 6 Ø6. (.0) Sensor with protective cap (stainless steel) ~69 (6.6) 90 (7.) 8. (0.7) 7 Ø6. (.0) 8 (.9) 6 7 Cable, sheat Ø 8. (0.) - (blue) (brown) Protective conductor connection/equipotential bonding (white) Vent pipe with humidity filter Ø (0.0) (inner diameter) Protective cap (PPE or PTFE) with x Ø. (0.0) holes Protective cap (stainless steel) with x Ø (0.0) holes Cable hanger, dimensions in mm (inch) More information Determination of the measuring range for medium water SITRANS LH00 pressure transmitter, dimensions in mm (inch) 86 (.9) (.0) 7 (.6) 7 (0.07) 98 (.86) 0 (.) H r Fastening hole Vent valve 6 (.) Cable gland Pg., cable diameter... 8 mm ( ) Junction box, dimensions in mm (inch) 7 (0.07) 0 (.) Calculation of the measuring range: p = x g x H with: = density of medium g = local acceleration due to gravity H = maximum level Example: Medium: Water, = 000 kg/m Acceleration due to gravity: 9.8 m/s Start-of-scale: 0 m Maximum level: 6.0 m Cable length: 0 m Calculation: p = 000 kg/m x 9.8 m/s x 6.0 m p = N/m p = 89 mbar Transmitter to be ordered: 7MF7-FA0 Plus, if required, junction box 7MF7-8AA and cable hanger 7MF7-8AB 6 Siemens FI 0 News January 07

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description Siemens AG 207 SITRANS P0 - Technical description Overview SITRANS P0 pressure transmitters are digital pressure transmitters with a high level of operating convenience. With a measurement accuracy of

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Z7A. Load cells. Special features. Data sheet. Wiring code

Z7A. Load cells. Special features. Data sheet. Wiring code Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

Type UB1 Load Cell. Option Stainless steel cable gland

Type UB1 Load Cell. Option Stainless steel cable gland Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

1. Mark the correct statement(s)

1. Mark the correct statement(s) 1. Mark the correct statement(s) Figure to the right shows a mass measurement scale using a spring. 1.1 The span of the scale is a) 16 kg b) 21 kg c) 11 kg d) 5-16 kg 1.2 The range of the scale is a) 16

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type

Certificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 1 of 8 Subject and Type VEGAFLEX FX81(*). I * * ** * * * * * * * Certificates: X = no, M - yes adjustment / indication module PLICSCOM X = without: A

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature ph/o.r.p. probe For many different types of installations and applications Large selection of probe for a wide range of holder Useable for pipe DN15 to DN200 Type 8203 can be combined with... Type 8200

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Reflex-Radar BM 100 A

Reflex-Radar BM 100 A KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information

Physikalisch-Technische Bundesanstalt

Physikalisch-Technische Bundesanstalt Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (13) S C H E D U L E (14) EC-TYPE-EXAMINATION CERTIFICATE PTB 99 ATEX 2139 X (15) Description of equipment The TH-series measuring transducers

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS

Safir-M smart. Features. Dot-matrix display and controls. Industries. Applications. y Reference accuracy, % FS y Reference accuracy, % FS 0. 0.5 0.25 0.5 y Turndown :0 Features y Output 20 ma, 0 5 ma, HART 7.0 Linear (increasing or decreasing) Square root (differential pressure) y Damping predefined set (0; 0.5;

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

SmartLine Radar Level Meter RM70

SmartLine Radar Level Meter RM70 Page 1 of 5 SmartLine Radar Level Meter Model Selection Guide Reliable measurement in difficult process conditions +/- 3 mm / +/-0.12" standard accuracy Operates up to a flange temperature of 200 0 C /

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

Installation Equipment

Installation Equipment Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

Field mounted Temperature Transmitter TF212/TF212-Ex

Field mounted Temperature Transmitter TF212/TF212-Ex Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote

More information

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg) CLEVIS FITTINGS B169 TWO HOLE SPLICE Wt./C 84 Lbs. (38.1 kg) B168 THREE HOLE SPLICE Wt./C 126 Lbs. (57.1 kg) B167 Wt./C 178 Lbs. (80.7 kg) 3 1 /2 (88.9) B170 TWO HOLE SPLICE Wt./C 123 Lbs. (55.8 kg) 5

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

KTY-84. Product information for which Carbex bears no responsibility is provided by the manufacturer.

KTY-84. Product information for which Carbex bears no responsibility is provided by the manufacturer. The KTY 84 is a temperature-dependent semi-conductor with a positive temperature coefficient. Typical for these sensors is the monitoring of temperatures and limit values in the field of industrial metrology.

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

Analogue Meters CQ2x07 series

Analogue Meters CQ2x07 series Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

TÜV NORD CERT GmbH Am TÜV 1 30519 Hannover IECEx Certification Body Page 1 of 3 Issue No. 2 of IECEx TUN 06.0014 X IECEx TR: File reference: DE/TUN/ExTR06.0059/02 07 203 554192 IECEx QAR: DE/QAR/TUN/06.0002/00

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,

More information

Industrial Resistance Thermometers according to DIN Model MWD

Industrial Resistance Thermometers according to DIN Model MWD Industrial Resistance Thermometers according to DIN measuring monitoring analysing MWD OMeasuring O range: -98... +600 ºC O O Pt00 sensor: class A, class B, class /3, class /0, or O O Output: resistance

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount 20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input

More information