Designed to go where you work
|
|
- Aldous Carroll
- 5 years ago
- Views:
Transcription
1 Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers! Accurate and repeatable to ± 0.05 C over its full range, the 55A/55A Stik Thermometer is the new gold standard of industrial temperature calibration. Whether working outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant, the intrinsically-safe, batteryoperated, portable reference thermometer is designed to go where you work. Features at a glance Accuracy of ± 0.05 C (± 0.09 F) over full range Intrinsically safe (ATEX and IECEx compliant) Two models to choose from (-50 C to 0 C or -80 C to 00 C) User-configurable temperature trend/stability indicator Display temperature in C or F Optional data logging to internal memory 00-hour battery life Percent battery-life and low-battery indicator NVLAP-accredited, NIST-traceable calibration included Shop for Fluke products online at:
2 Thermometer probe and digital readout combined into one unit The stainless steel probe and digital readout are fixed together and calibrated as a system. The accuracy specification is easy to understand since it includes all uncertainty components, including drift, for up to one year. The large backlit LCD display rotates 90 making it easy to read from any angle. A user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to three hundred hours. A low-battery indicator and stop-measure function prevent erroneous measurements from being made due to low battery life. A simple three-point calibration function allows you to easily and accurately calibrate the Stik Thermometer. Data logging to internal memory of up to 0,000 time-stamped measurements is optionally available. Why calibrate process temperature sensors? Because temperature greatly effects the accuracy of a volumetric measurement, process manufacturers of chemical, pharmaceutical, food or petroleum products require accurate temperature measurements especially for processes where quality or custody transfer are regulated by government agencies. Since all temperature sensors are subject to drift with time, regular calibration or verification against a reliable reference thermometer is required. Finding a reference thermometer that is accurate, repeatable and robust, however, can be challenging. What s wrong with my reference thermometer? Industrial reference thermometers available on the market today, such as mercury-in-glass thermometers (or ASTM thermometers ) and portable electronic thermometers are useful, but both come with inherent problems. Although accurate and repeatable, mercury thermometers are fragile. The risk of a mercury spill poses potential hazards to the environment and to the health of personnel. Many of the United States and European Union countries have already banned their use in industrial applications. Some organizations have replaced their mercury thermometers with more durable portable electronic thermometers, only to discover that the RTD probes lack the repeatability and dependability required of a legitimate reference thermometer. The best alternative to mercury thermometers The Fluke Stik Thermometer is accurate, stable and durable, making it the best alternative to mercury thermometers and existing electronic thermometers. The thin-film RTD sensor incorporates the same characteristics of other premium reference thermometers designed by Hart Scientific, but it is more robust and less susceptible to drift. Accuracy and repeatability, however, are not sacrificed for improved durability. Using a glass-stem mercury- or spirit-filled thermometer at different immersion depths, or at significantly different ambient temperatures from which it was calibrated, may require the application of emergent-stem corrections that can be tedious but necessary to calculate an accurate measurement. This isn t required with the Stik Thermometer. The sensor of the 55A Ex requires a minimum immersion depth of only 7 cm (.8 in), with no appreciable effect on the measured temperature due to heat loss through stem conduction. Some digital thermometers can become less accurate when used outside a narrow range of ambient temperatures. This isn t the case for the Stik Thermometer. Your measurement remains accurate in ambient temperatures from -0 C to 50 C ( F to F). With a superior probe design combined with electronic functions that assist accurate measurement, the Stik Thermometer surpasses the capabilities of other digital thermometers and is the perfect substitute for your mercury thermometers. In order to minimize sensor drift, the probe should always be protected from mechanical shock. Shop for Fluke products online at:
3 Easy-to-use, one-handed menu navigation The digital display and probe are fixed together as a system. The hinge allows the display to rotate 90 to easily view the measurement from any angle. Easily power up with the press of a button and after a short selftest, start making measurements within seconds. The power key is slightly recessed inside the plastic molded case to protect against accidental power off. 5 7 The Setup/Down key lets you step through submenus and adjust field values down. The Enter/Backlight key allows you to accept changes while in the setup menus or turn on the backlight. User-selectable resolution (0., 0.0, 0.00) Temperature displayed in C or F. Max/Min/Trend/Up key allows you to see the maximum or minimum temperature since the most recent power up. The trend function tells you the positive or negative rate of temperature change in degrees per minute. 8 The stability/trend indicator tells you if your temperature source is trending upward or downward (pictured trending up). A flat bar indicates that the temperature source and thermometer are stable within the user-selected stability window (0.0, 0.,.0, 0.0). Shop for Fluke products online at:
4 55A Ex/55A Ex Specifications Specifications 55A Ex 55A Ex Temperature range -50 C to 0 C (-58 F to 0 F) Accuracy ( year) ± 0.05 C (± 0.09 F) Display units C, F -80 C to 00 C ( - F to 57 F) Sensor type 00 Ω thin-film RTD 00 Ω wire-wound PRT Probe temperature coefficient Ω/Ω/ C nominal Sensor length 0 mm 0 mm Sensor position (from sheath tip) mm (0. in) Minimum immersion depth 7 cm (.8 in) cm (.8 in) Probe sheath material Response time.8 mm diameter probe (/ in): seconds.5 mm diameter probe (/ in): seconds Probe hysteresis ± 0.0 C Temperature resolution Selectable: 0., 0.0, 0.00 (default 0.0) Sample rate Selectable: 0.5 seconds, seconds, seconds (default seconds) Operating temperature range -0 C to 50 C ( F to F) readout Storage temperature -0 C to 0 C (- F to 0 F) 0 % to 95 % RH, non-condensing Optional data logging Up to 0,000 time-stamped readings stored to internal memory Logging intervals seconds, 5 seconds, 0 seconds, 0 seconds, or 0 seconds; minutes, 5 minutes, 0 minutes, 0 minutes, or 0 minutes Damping Moving average of the most recent to 0 readings (ON/OFF,, 5, 0) Communications RS- stereo jack (access calibration parameters only) AC power None DC power Three AAA batteries, typical battery life of 00 hours without LCD backlight EMC compliance EN:00 Annex C; CISPR II Edition ; Class B Enclosure rating IP50 Electronics dimensions (H x W x D) Weight Calibration (included) SST mm x 57 mm x 5 mm (.5 in x.5 in x.0 in) 9 g (.9 oz) NVLAP-accredited, NIST-traceable Characterization CVD ITS-90 Per ASTM E See ordering information for optional data logging configurations Shop for Fluke products online at:
5 Ordering information 55A Ex 55A-9.8 mm x 9 mm (/ in x 9 in) 55A- 55A-0.5 mm x 508 mm (/ in x 0 in) 55A Ex 55A- Thermometer, Fixed PRT, -80 C to 00 C, 55A--DL Thermometer, Fixed PRT, -80 C to 00 C, Accessories 55A Ex Datalogging options 55A-9-DL 55A--DL 55A-0-DL.8 mm x 9 mm (/ in x 9 in).5 mm x 508 mm (/ in x 0 in) 55-CASE 55-CBL Case, 55-, Carrying Cable, RS- 55X Standard accessories include: NVLAP-accredited report of calibration, User s Guide on CD-ROM, three AAA batteries Note: Model number appended with a -9, -, -0 indicates probe sheath length in inches. All probe diameters are.5 mm (/ in) with the exception of the 55A-9, which is.8 mm diameter (/ in). Shop for Fluke products online at: 7 7
1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration
1551A Ex/155A Ex Intrinsically Safe Stik Thermometer The new gold standard of industrial temperature calibration Designed to go where you work Finally, a digital substitute for your mercury-in-glass thermometers!
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationUnderstanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator
Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator Introduction Humidity generators are mechanical devices that provide stable temperature and humidity
More informationUnderstanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator
Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator Technical Note The Fluke Calibration 5128A RHapid-Cal Humidity Generator provides a portable, stable test environment
More information566/568. Infrared Thermometers. Getting Started
566/568 Infrared Thermometers Getting Started PN 2812159 August 2007 Rev. 2, 4/08 2007-2008 Fluke Corporation. All rights reserved. Printed in China. Product specifications are subject to change without
More informationThermometer Line. today s laboratory and field
Thermometer Line The VEE GEE Thermometer line consists of a large selection of high-quality instruments to meet the general and specific requirements for temperature analysis in today s laboratory and
More informationInstruction Manual SEFRAM Thermal Camera
Instruction Manual SEFRAM 9830 Thermal Camera EN Introduction The SEFRAM 9830 Thermal Camera (the Product) can display thermal gradient, temperature readings, map and measure the infrared energy radiated
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationModel ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com
Model ST-616CT Infrared Thermo-Hygrometer Instruction Manual reedinstruments com Table of Contents Safety... 2 Features... 3 Specifications...4-5 Instrument Description...6-7 Operating Instructions...8-10
More informationHot solutions for temperature measurement. Contact and non-contact thermometers from Fluke
Hot solutions for temperature measurement Contact and non-contact thermometers from Fluke Infrared thermometry explained With the 60 Series and 570 Series, Fluke offers you a wide choice of non-contact
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More information473 Dew Point Hygrometer
gh Performance Chilled Hygrometer With Cable Mounted Measuring Heads ghly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct insertion
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More information473-SHX Dew Point Mirror
Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationph / Temperature Meter for Cheese with Application Specific Probe
C/ F ph / Temperature Meter for Cheese with Application Specific Probe ph Application Importance ph is an essential measurement throughout the entire cheesemaking process. From the initial measurements
More informationDual laser + type K thermometer INFRARED THERMOMETER
Dual laser + type K thermometer INFRARED THERMOMETER Model : ATE-2509 Your purchase of this INFRARED THERMOMETER marks a step forward for you into the field of precision measurement. Although this METER
More informationData Loggers Outdoor Environment
Data Loggers Outdoor Environment The HOBO RG3 (or RG3-M) data logging rain gauge is a selfcontained device that includes an integrated data logger with a high-quality tipping-bucket rain gauge. The RG3
More information2.1. Accuracy, n- how close the indication of the thermometer is to the true value.
AASHTO Accreditation Policy and Guidance on Thermometer Selection and Records Revised: January 25, 2018 Revision #: 0 1. Objective 1.1. The purpose of this document is to clearly define acceptance criteria
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationA Case for Periodic Calibration or Verification of RTDs
A Case for Periodic Calibration or Verification of RTDs If you are experiencing audio problems please call the teleconference number below Phone 650-479-3208 Access code 668 676 434 Your Host and Presenter
More informationKestrel 4500 Pocket Weather Tracker
Kestrel 4500 Pocket Weather Tracker For years our customers have been asking for wind direction along with wind speed. New for 2007, the Kestrel 4500 does just that with its built in digital compass. But
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationTraceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.
THERMOMETERS Type-K Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away Intuitive, four-key operation makes this thermometer extremely easy to use Max HOLD feature permits
More informationHL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual
HL-800K Infrared Laser Thermometer -50 C to +800 C (13:1 ratio) User Manual TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 3 WIDE APPLICATION RANGE... 3 SAFETY... 3 DISTANCE & SPOT SIZE... 4 SPECIFICATIONS...
More informationUser Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration
User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationThermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement
We measure it. Thermal anemometer testo 405 Flow velocity measuring instrument with temperature measurement Volume flow measurement up to 99,990 m³/h Extendable telescope up to 300 mm m/s C Display illumination
More informationIR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer
INSTRUCTION MANUAL Thermometer DUAL-LASER TARGETING 12:1 DISTANCE- TO-SPOT RATIO AUTO-SCAN MAX/MIN/AVG/DIFF HIGH/LOW ALARM BACKLIT DISPLAY AUTO POWER-OFF ADJUSTABLE EMISSIVITY IR5 2m -22 752 F (-30 400
More informationEdgetech Instruments Inc.
2015_07_ETI OVERVIEW Rev 3 MADE IN THE USA Edgetech Instruments (ETI) is a USA company based in Massachusetts. We have over 50 years of expertise in the design and manufacture of a comprehensive range
More informationRapid RH Portable ph Meter. User's Manual
Rapid RH Portable ph Meter User's Manual This page intentionally left blank. 2 Contents 1. Introduction... 4 2. Included with the Rapid RH Portable ph Meter... 4 3. Understanding ph... 5 4. Calibrating
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationInfrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationThermometers. Applications
92 Temperature Thermometers Thermometers On the next pages you will find a broad range of thermometers with fixed probes or exchangeable probes with rigid probes or probes with cable and hand grip. The
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationEM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER Users Manual -1- .Introduction
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationIntroduction. Measurement of temperature is generally considered to be one of the simplest and most accurate measurements performed in engineering.
Slide Nr. 0 of 15 Slides Introduction Measurement of temperature is generally considered to be one of the simplest and most accurate measurements performed in engineering. Some important considerations
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationVaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance
Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 Fast Response - Low Maintenance DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand- Held Dewpoint Meter DM70 offers accurate
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationThe Fluke 66 and 68 Infrared Thermometers
The Fluke 66 and 68 Infrared Thermometers Non-contact temperature measurement Technical ata The professional s diagnostic tool The Fluke 66 and Fluke 68 non-contact thermometers are the ideal professional
More informationIR and contact thermometers
IR and contact thermometers Providing the total temperature solution for your application Electrical Plant Maintenance HVAC Quality control Process Shop for Fluke products online at: www. MyFlukeStore.com
More informationWATER ACTIVITY MEASUREMENT WATER ACTIVITY
MEASUREMENT WATER ACTIVITY FAST AND PRECISE WATER ACTIVITY MEASUREMENTS. INTRODUCING AIRCHIP DIGITAL TECHNOLOGY. Determine product quality with ROTRONIC Aw products ROTRONIC Aw devices for laboratory and
More informationInfrared Thermometer Calibration A Complete Guide
Infrared Thermometer Calibration A Complete Guide Application note With proper setup and planning, infrared calibrations can be accurate. The steps outlined below should be followed to perform accurate
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationInfraRed Thermometer with Laser Pointer
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com InfraRed Thermometer with Laser Pointer MODEL IR400 Introduction Congratulations
More informationOverview of the Thunderbird Micronet
Fall 2004 Dr. Petra Klein Sean Arms Overview of the Thunderbird Micronet Introduction The Lake Thunderbird Micronet is a micrometeorological measurement network intended to obtain data on fine-scale spatial
More informationAcceleration/Velocity/Displacement VIBRATION METER
Acceleration/Velocity/Displacement VIBRATION METER Model : VB-8220 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationThe Fundamentals of Moisture Calibration
The Fundamentals of Moisture The following guide will provide you with a basic knowledge of humidity calibration, help you to understand your requirements and select an appropriate solution. 1 Why Humidity
More informationThermal Mass Flow Meter for Gases
Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving
More informationWhite Paper. Perform Conductivity Measurements In Compliance with USP <645>
Perform Conductivity Measurements In Compliance with USP Water is the most widely used substance, raw material, or ingredient in the production, processing and formulation of compendial articles.
More informationAir velocity & IAQ measuring instruments
Data sheet dp Air velocity & IAQ measuring instruments - air velocity & IAQ measuring instrument - dp air velocity & IAQ measuring instrument incl. differential pressure C CO Intuitive: clearly structured
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationTHERMOFOCUS, a technological innovation
06600 THERMOFOCUS, a technological innovation Thermofocus Animal is the evolution of Thermofocus, the world's first non-contact thermometer intended for human use. With Thermofocus, Tecnimed introduced
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com INSTRUCTION MANUAL Milwaukee Refractometer MA871 Refractometer for Sucrose Measurements 1 Instruction Manual
More informationReflex-Radar BM 100 A
KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters
More informationStructure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor
Rain detection sensor General Description Driving rain and its effective management are critical factors in determining the durability of building enclosures. An accurate measurement of driving rain can
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSA101 Exchangeable measuring insets 2 SENSYTEMP TSA101 EXCHANGEABLE MEASURING INSETS DS/TSA101-EN REV. E Measurement made easy Compatible
More informationOverview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen
Overview Brochure 2016 Comprehensive range of instrumentation for the measurement of moisture and oxygen Overview Brochure Relative Humidity Probes and Transmitters Repeatable RH and temperature measurement
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationDewpoint Meter Data Sheet / Instructions
Paint Test Equipment Dewpoint Meter Data Sheet / Instructions Dewpoint Meter Information ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment
More informationThe Development of a High-Temperature PRT Calibration Process Based On Dry- Block Calibrators
The Development of a High-Temperature PRT Calibration Process Based On Dry- Block Calibrators Michael Coleman Fluke Corporation, Temperature Calibration Division, American Fork, Utah, USA mike.coleman@fluke.com
More informationStick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model
Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model 35625-15 THE STANDARD IN PRECISION MEASUREMENT 1 DGMAN_35625-15_(ENG_FR).indd 1 7/8/2014
More informationDISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS
FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS 52-058-016 Fine quality vernier calipers are constructed of stainless steel. 52-057-004 offers 3-way measurement to accuracy. 52-058-XXX series
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationNew Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018
New Thermometer Guidance Document from AASHTO Accreditation Program Maria Knake Asphalt Binder ETG Meeting May 10, 2018 Background Mercury reduction initiatives have hastened the need to find suitable
More informationDHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual
DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual WD1063 Rev B Revised 02/23/15 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131
More informationLatest generation testo air velocity & IAQ probes with cable handle. Instruction manual
Latest generation testo air velocity & IAQ probes with cable handle Instruction manual Contents Contents 1 About this document... 5 2 Safety and disposal... 5 3 System description... 6 4 Description of
More informationData Sheet / Instructions. Dewpoint MeterO
Data Sheet / Instructions Dewpoint MeterO Dewpoint Meter ISO 8502-4: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface cleanliness.
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationInstruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements
Instruction Manual HI 96811 Refractometer for Sucrose in Wine and Grape Products Measurements TABLE OF CONTENTS PRELIMINARY EXAMINATION... 2 GENERAL DESCRIPTION... 3 SPECIFICATIONS... 3 PRINCIPLE OF OPERATION...
More informationOf all the physical properties, it is temperature, which is being measured most often.
1. Temperature 1.1 Introduction Of all the physical properties, it is temperature, which is being measured most often. Even the measurement of other physical properties,e.g. pressure, flow, level,, often
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationAcceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202
Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is
More informationPG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive
HANDY MANOMETER Power button Hold button marking Compatible with EMC directive Digital 3 1/2 digits Zero adjustment VR FEATURES Excellent stability State of the art sensor and circuit technology guarantees
More information792A AC/DC Transfer Standard
92A AC/DC Transfer Standard Technical Data Support for your most demanding ac measurement requirements ppm total uncertainty Traceable to national standards range: 2 mv to 00 V Frequency range: Hz to 1
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationINSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements
www.milwaukeeinst.com INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements www.milwaukeeinst.com 1 Instruction Manual MA881 Refractometer for Invert Sugar Measurements
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200508-0 Insco Metrology, Inc. Miami, FL is accredited
More informationChemistry MultiMeasure Sensor PS-2170
ä 5 Instruction Manual 012-09523A Chemistry MultiMeasure Sensor PS-2170 ph/ise/orp PRESSURE CHEMISTRY TEMPERATURE SENSOR VOLTAGE 1 2 3 4 PS-2170 5 6 7 cc 8 10 15 20 25 30 35 40 45 50 55 60 Included Equipment
More informationIntuitive air velocity and IAQ.
Intuitive air velocity and IAQ. The new combines versatility and maximum convenience. 1 The new air velocity & IAQ measuring instrument: versatility in a compact format. Welcome to a new era: the new combines
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationOperating instructions Pressure sensor PN / / 2007
Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationINNOVATION IN MAGNETICS DS0003/18. Mag-01H. Single Axis Fluxgate Magnetometer.
INNOVATION IN MAGNETICS DS0003/18 Mag-01H Single Axis Fluxgate Magnetometer www.bartington.com Mag-01H Single Axis Fluxgate Magnetometer Mag-01H Single Axis Fluxgate Magnetometer This portable, high performance
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More information