Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Size: px
Start display at page:

Download "Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,"

Transcription

1 E X - L I G H T F I T T I N G S nllk W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive 4//EC. They are designed and tested acc. to the latest standard IEC EN 07- for Ex equipment for use in zone 2 and EN for use in Zone 21 and Zone 22 of dust Ex-areas. They are equipped with electronic ballasts (EVGs) for G13 bi-pin fluorescent lamps. The new EVG additionally fullfills the relevant requirements of End of Life (EOL) acc. IEC 07-7 for explosion protected fluorescent light fittings design increased safety. The standard single-sided throughwiring architecture in conjunction with the generously large terminal compartment offers a cost efficient installation. Double-sided lock with 10, 20 or 24 latch points allows the protective bowl to be hingeable on both sides meaning the fitting can be mounted without having to pay attention to which side is the right side. With the optional CG-S module, single monitoring of the lamp is possible with the CEAG Emergency Light Supply Systems. Cost efficient installation due to single-sided through-wiring With electronic ballast incl. EOL set-up Double-sided safety lock Safety standard IP66 Integration in the CEAG Emergency Light Supply System 2.6 Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

2 I nllk 001/1 I nllk 0036 I nllk 0036/36 I nllk 00 I I nllk 00/ I x 1 W 1 x 36 W 2 x 36 W 1 x W 2 x W Technical data 3 nllk 001/1 nllk 0036 nllk 0036/36 nllk 00 nllk 00/ Marking to 4//EC II 3 G Ex na de/de mb IIC T4 II 3 D Ex td A22 IP66 T0 C II 2 D Ex td A21 IP66 T0 C Examination Certificate BVS 0 ATEX E 147 EC-Type Examination Certificate BVS 0 ATEX E 162 Permissible ambient temperature 2 C to +0 C / 2 C to + C (2 x W) 2 C to + C (2 x 36 W 2/ + 2/6, excl. CG-S-Version) Rated voltage AC 220 V - 2 V AC Rated voltage AC (CG-S) 220 V - 24 V AC Rated voltage DC 220 V - 2 V DC Rated voltage DC (CG-S) 1 V - 20 V DC Frequency 0 - Hz Power factor cos ϕ >= 0. Circuit EVG resp. EVG/CG-S Connecting terminals L1, N, PE (option L1, L2, L3, N, PE) max. 2 x 2. mm 2, clamp terminals; optional screw-type terminals max. 2 x 6 mm 2 (L1, L2, L3, L, N, PE) Insulation class I Lamp cap G13 accd. to IEC 01 Degree of protection accd. EN 2 IP66 Cable glands/gland plates/enclosure drilling Ex e cable glands M2 x 1. (plastic) for cables from Ø - 17 mm Option: M20 x 1. metal thread Enclosure material Glass-fibre reinforced polyester Protective cover/protective bowl Polycarbonate nllk 001/1 Rated current 0.16 A / 0.17 A (CG-S variant) Lamp/illuminant 2 x T26 / 1 W Rated luminous flux 1) 2700 lm Light efficiency in operation 7 % Dimensions (L x W x H) 7 x 1 x 1 mm Weight approx. 3.6 kg / approx..6 kg (CG-S variant) nllk 0036 nllk 0036/36 Rated current 0.16 A 0.34 A / 0.3 A (CG-S variant) Lamp/illuminant 1 x T26 / 36 W 2 x T26 / 36 W Rated luminous flux 1) 330 lm 6700 lm Light efficiency in operation 6 % 7 % Dimensions (L x W x H) 13 x 1 x 1 mm 13 x 1 x 1 mm Weight approx..6 kg approx.. kg /approx..0 kg (CG-S variant) 10 nllk 00 nllk 00/ Rated current 0.27 A 0.3 A / 0.4 A (CG-S variant) Lamp/illuminant 1 x T26 / W 2 x T26 / W Rated luminous flux 1) lm 100 lm Light efficiency in operation 3% 72% Dimensions (L x W x H) 16 x 1 x 1 mm 16 x 1 x 1 mm Weight approx. 6.7 kg approx. 6. kg / approx..0 kg (CG-S variant) 1) depends on used lamps COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

3 I nllm 001/1 I nllm 0036/36 I nllm Technical data nllm 001/1 nllm 0036/36 Marking to 4//EC II 3 G Ex na de/de mb IIC T4 II 3 D Ex td A22 IP66 T0 C II 2 D Ex td A21 IP66 T0 C Examination Certificate BVS 0 ATEX E 147 EC-Type Examination Certificate BVS 0 ATEX E 162 Permissible ambient temperature -2 C to +0 C Rated voltage 220 V - 2 V AC Rated voltage 220 V - 2 V DC Frequency 0 - Hz Power factor cos ϕ 0. Circuit EVG Connecting terminals L, N, PE screw-type terminals max. 2 x 6 mm 2 Insulation class I Lamp cap G13 accd. to IEC 01 Degree of protection accd. EN 2 IP66 Cable glands 1 x Ex e cable glands M2 x 1. (plastic) for cables from Ø - 17 mm Enclosure material Glass-fibre reinforced polyester Protective cover/protective bowl Polycarbonate nllm 001/1 nllm 0036/36 Rated current 0.16 A 0.34 A Lamp/illuminant 2 x T26 / 1 W 2 x T26 / 36 W Rated luminous flux 1) 2700 lm 6700 lm Light efficiency in operation 7 % 7 % Dimensions (L x W x H) 7 x 1 x 1 mm 13 x 1 x 1 mm Pole socket Ø 44 mm x 0 mm Ø 44 mm x 0 mm Weight approx. 6.1 kg approx..4 kg 1) depends on used lamps 2. COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

4 I nllk 001/1 I nllk 0036 I nllk 0036/36 I nllk 00 I I nllk 00/ I nllm 001/1 I nllm 0036/36 I x 1 W 1 x 36 W 2 x 36 W 2 x 1 W 2 x 36 W Ordering details 3 Type Terminals Through-wiring Cable glands 2) Plugs Order No. single-ended double-ended Type nllk 001/1 (2 x 1 W) 1/3-1 1 x 3 x 1 x M2 x 1. 1 x threaded /-2 2 x x 2 x M2 x 1. 2 x threaded /6-2 M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllk 001/1 CG-S 2) (2 x 1 W) 2/6-2 4) 2 x 6 x 2 x M2 x 1. 2 x threaded /6-M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllm 001/1 (2 x 1 W) 1/3-1 1 x 3 1 x M2 x Type nllk 0036 (1 x 36 W) 1/3-1 1 x 3 x 1 x M2 x 1. 1 x threaded /-2 2 x x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllk 0036/36 (2 x 36 W) 1/3-1 1 x 3 x 1 x M2 x 1. 1 x threaded /-2 2 x x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllk 0036/36 CG-S 2) (2 x 36 W) 2/6-2 4) 2 x 6 x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllm 0036/36 (2 x 36 W) 1/3-1 1 x 3 1 x M2 x Type nllk 00 (1 x W) 1/3-1 1 x 3 x 1 x M2 x 1. 1 x threaded /-2 2 x x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllk 00/ (2 x W) 1/3-1 1 x 3 x 1 x M2 x 1. 1 x threaded /-2 2 x x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded Type nllk 00/ CG-S 2) (2 x W) 2/6-2 4) 2 x 6 x 2 x M2 x 1. 2 x threaded /6-2M 1) 4) 2 x 6 x 4 x M20 x 1. 2 x threaded ) M: with metal thread, without cable gland 2) CG-S: design single monitored emergency light fitting for use in CEAG emergency light supply unit 3) With dustcover if entry/thread is not closed 4) With screw-type terminals max. 2 x 6 mm Version with integrated isolating switch on request Scope of delivery without lamp and fixing accessoires 11 COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

5 I nllk 001/1 I nllk 0036 I nllk 0036/36 I nllk 00 I I nllk 00/ I nllm 001/1 I nllm 0036/36 I 2 x 1 W 1 x 36 W 2 x 36 W 1 x W 2 x W Accessories Lamp for luminaire nllk0/nllm0 Type of lamp Power Luminous flux Order No. Light colour Bi-pin socket G13 1 W 130 lm white T26/Ø 26 mm (T) G13-01-IEC Bi-pin socket G13 36 W 330 lm white T26/Ø 26 mm (T) G13-01-IEC Bi-pin socket G13 W lm white T26/Ø 26 mm (T) G13-01-IEC Aura-Ultimate 1 W 10 lm white T26/Ø 26 mm (T) Longlife 36 W 330 lm white Socket G13 W lm white on request Series nllk 0... and nllm 0... Type Order No. Hexagon screw SW Series nllm 001/1 and nllm 0036/36 Type Order No. Single sided through wiring 2/6 with 2 entries M2, incl. terminals and mounting material Fixing materials nllk 0 Type/code Corrosion Qty. Order No. protection per light fitting Eye bolt A2 galvanized Hexagon screw S4 stainless steel Ceiling mounting bracket D2 stainless steel incl. screws and washer Fixing materials nllk 0... and nllm 0... Type/code Corrosion for pipes Outer Ø Qty. Order No. protection DIN D (mm) per light fitting Pipe clamp R12 hot galvanized 1 1 / R14 CrNi 1 1 / R22 hot galvanized 1 1 / R24 CrNi 1 1 / R32 hot galvanized R34 CrNi Wall bracket W27 hot galvanized Luminaire wall suspension hot galvanized incl. screws and washer Metal cable glands M20/M2 see page.10. Complete Mounting Systems see page 2.70 to COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

6 I nllk 001/1 I nllk 0036 I nllk 0036/36 I nllk 00 I I nllk 00/ I nllm 001/1 I nllm 0036/36 I x 1 W 1 x 36 W 2 x 36 W 1 x W 2 x W Dimension drawing Polar curve Accessories 3 3. M2 x 1. 1 W = W = 1332 W = W = 0 36 W/ W = 700 Hexagon SW 13, 14 deep Polar curve nllk/m 001/1 / nllk/m 0036/36 1 W = 7 36 W = 13 W = 16 Polar curve nllk/m 0036 / nllk 00 Polar curve nllk 00/ C 0 C 1 0 l/cd/klm C 0 C 1 0 l/cd/klm C 0 C 1 0 l/cd/klm 7 20 Ø x 13 Eye bolt Wall bracket Ø D Ø10 7 Ø10 6 Ceiling mounting bracket D2 Pipe clamp Luminaire wall suspension COOPER CROUSE-HINDS GMBH 2.61 Dimensions in mm Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

7 EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive 4//EC. They are designed and tested acc. to the latest standard IEC EN 07- for Ex equipment for use in zone 2 and EN for use in Zone 21 and Zone 22 of dust Ex-areas. They are equipped with electronic ballasts (EVGs) for G13 bi-pin fluorescent lamps and are available for 1 W and 36 W. Additionally it fullfills the relevant requirements End of Life (EOL) acc. IEC 07-7 for explosion protected fluorescent light fittings design increased safety as well as for mains operation and for emergency light operation. Additionally the light fittings fullfill the requirements acc. EN part 2-22 for emergency light fittings. They are fitted with a self contained battery for maintained and non maintained mode. The light fitting has an emergency lighting duration time of 1. h, alternativ 3.0 h and a green indication LED for charging current and fault indication. The standard single-sided through-wiring architecture in conjunction with the generously large terminal compartment offers a cost efficient installation. Double-sided lock with 10 resp. 20 latch points allows the protective bowl to be hingeable on both sides meaning the fitting can be mounted without having to pay attention to which side is the right side. Maintenance-friendly the self-contained battery is mounted beneath a reflector-flap. Versions with double sided through wiring have a flanged battery housing. Cost efficient installation due to single-sided through-wiring With electronic ballast incl. EOL set-up Double-sided safety lock High degree of protection IP66 Self-contained NC-battery for emergency lighting 1. h, alt. 3.0 h Easy battery change 2.62 Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

8 I nllk 001/1 N I nllk 0036/36 N I x 1 W 1/6 2 x 36 W 1/6 2 x 36 W N 2/6 Technical data 3 nllk 001/1 N 1/6 nllk 001/1 N 2/6 nllk 0036/36 N 1/6 nllk 0036/36 N 2/6 Marking to 4//EC II 3 G Ex na de/de mb IIC T4 II 3 D Ex td A22 IP66 T0 C II 2 D Ex td A21 IP66 T0 C Examination Certificate BVS 0 ATEX E 147 EC-Type Examination Certificate BVS 0 ATEX E 162 Permissible ambient temperature -2 C to + C / -2 C to + C (2 x 36 W 2/6) (specified data: - C to +3 C) Rated voltage 220 V - 2 V AC Frequency 0 - Hz Power factor cos ϕ >= 0. Circuit EVG with emergency lighting supply Connecting terminals L1, L2, L3, L, N, PE, max. 2 x 6 mm² per terminal Insulation class I Lamp cap G13 accd. to IEC 01 Light efficiency in operation 7% Rated emergency operation duration 1. h / 3 h Charging duration > 24 h Degree of protection accd. EN 2 IP66 Cable glands/gland plates/enclosure drilling 1) Ex e cable glands M2 x 1. (plastic) for cables from Ø - 17 mm Option: M20 x 1. metal thread Enclosure material Glass-fibre reinforced polyester Protective cover/protective bowl Polycarbonate nlllk 001/1 N 1/6 nlllk 001/1 N 2/6 2) Rated current 0.1 A 0.1 A Lamp/illuminant 2 x T26 / 1 W 2 x T26 / 1 W Rated luminous flux 1) 2700 lm 2700 lm Luminous flux in emergency operation (1. h, one lamp) 1) 0 lm (6 %) 0 lm (6 %) Luminous flux in emergency operation (3 h, one lamp) 1) 4 lm ( %) 4 lm ( %) Battery 6 V/4 Ah NC Accu 6 V/4 Ah NC Accu Dimensions (L x W x H) 7 x 1 x 1 mm 0 x 1 x 1 mm Weight approx. 4. kg approx. 6.0 kg nllk 0036/36 N 1/6 nllk 0036/36 N 2/6 2) Rated current 0.36 A 0.36 A Lamp/illuminant 2 x T26/ 36 W 2 x T26/ 36 W Rated luminous flux 1) 6700 lm 6700 lm Luminous flux in emergency operation (1. h, one lamp) 1) 1 lm (36 %) 1 lm (36 %) Luminous flux in emergency operation (3 h, one lamp) 1) lm (31 %) Battery 6 V/4 Ah NC Accu 6 V/4 Ah NC Accu (1. h), 6 V/7 Ah NC Accu (3.0 h) Dimensions (L x W x H) 13 x 1 x 1 mm 00 x 1 x 1 mm Weight approx. 6. kg approx..3 kg (1. h), approx..3 kg (3.0 h) 1) depends on used lamps 2) Version 2/6 with seperate battery housing COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

9 I nllk 001/1 N I nllk 0036/36 N I 1 x 1 W 2/6 2 x 36 W 1/6 2 x 36 W N 2/6 Ordering details Type Connecting Through-wiring With M2 For M20 Rated emer- Order No. terminals plastic metal 2) gency lighting single-ended double-ended cable glands cable glands operation Type nllk 001/1 N 1/6 (2 x 1 W) 1/6-1 1 x 6 X X 1. h /6-1 M 1) 1 x 6 X X 1. h /6-1 1 x 6 X X 3 h /6-1 M 1) 1 x 6 X X 3 h Type nllk 001/1 N 2/6 (2 x 1 W) 3) 2/6-2 2 x 6 X X 1. h /6-2 M 1) 2 x 6 X X 1. h /6-2 2 x 6 X X 3 h /6-2 M 1) 2 x 6 X X 3 h Type nllk 0036/36 N 1/6 (2 x 36 W) 1/6-1 1 x 6 X X 1. h /6-1 M 1) 1 x 6 X X 1. h Type nllk 0036/36 N 2/6 (2 x 36 W) 3) 2/6-2 2 x 6 X X 1. h /6-2 M 1) 2 x 6 X X 1. h /6-2 2 x 6 X X 3 h /6-2 M 1) 2 x 6 X X 3 h ) M: with metal thread, without cable gland 2) With dustcover if entry/thread is not closed 3) Version 2/6 with separate battery housing Version with integrated isolating switch on request Scope of delivery without lamp and fixing accessoires Accessories Lamp for luminaire nllk0... N/nLLM0... N Type of lamp Power Luminous flux Order No. socket/ Light colour Diameter Bi-pin socket G13 1 W 130 lm white T26/Ø 26 mm (T) G13-01-IEC Bi-pin socket G13 36 W 330 lm white T26/Ø 26 mm (T) G13-01-IEC Aura-Ultimate 1 W 10 lm white T26/Ø 26 mm (T) Longlife 36 W 330 lm white Socket G13 Metal cable glands M20/M2 see page.10. Complete Mounting Systems see page 2.70 to COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

10 I nllk 001/1 N I nllk 0036/36 N I x 1 W 2/6 2 x 36 W 1/6 2 x 36 W N 2/6 Accessories 3 Series nllk 0... N Type Order No. Hexagon screw SW Series nllk 0... N Type Order No. Single sided through wiring 2/6 with 2 entries M2, incl. terminals and mounting material Fixing materials nllk 0... N Type/code Corrosion Qty. Order No. protection per light fitting Eye bolt A2 galvanized Hexagon screw S4 stainless steel Ceiling mounting bracket D2 stainless steel incl. screws and washer Fixing materials nllk 0... N Type/code Corrosion for pipes Outer Ø Qty. Order No. protection DIN D (mm) per light fitting Pipe clamp R12 hot galvanized 1 1 / R14 CrNi 1 1 / R22 hot galvanized 1 1 / R24 CrNi 1 1 / R32 hot galvanized R34 CrNi Luminaire wall suspension hot galvanized incl. screws and washer Battery nllk 0... N Type nllk 0... N 1/6, nllk 0... N 2/6 Order No. Battery set 6 V/4 Ah (... 1/1 N 1/6, 1. h and 3 h, 36/36 N 1/6, 1. h) Battery set 6 V/4 Ah (... 1/1 N 1/6, 1. h and 3 h, 36/36 N 1/6, 1. h) Battery set 6 V/7 Ah (... 36/36 N 2/6, 3 h) Metal cable glands M20/M2 see page.10. Complete Mounting Systems see page 2.70 to COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

11 I nllk 001/1 N I nllk 0036/36 N I 2 x 1 W 2/6 2 x 36 W 1/6 2 x 36 W N 2/6 Dimension drawing Polar curve 3. M2 x 1. 1 W = W = W = 0 36 W = 700 Hexagon SW 13, 14 deep W = 7 36 W = 13, 14 deep 1 W = 0 36 W = W = 0 36 W = 00 Hexagon SW 13 M2 x Polar curve nllk 001/1 N / nllk 0036/36 N Polar curve nllk/nllm 00../.. NIB in emergency operation C 0 C 1 0 l/cd/klm C 0 C 1 0 l/cd/klm D Ø10 Ø10 Dimensions in mm 6 7 Eye bolt Ceiling mounting bracket D2 Pipe clamp Luminaire wall suspension 2.66 COOPER CROUSE-HINDS GMBH Sales: Malux Finland Oy, P.O.Box 6, FI-061 Porvoo, Phone , Fax , info@malux.fi,

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm 1 E X - F L U O R E S C E N T L I G H T F I T T I N G S 2 3 6 EX-LIGHT FITTING ellk 2... MAIN FEATURES EX-LIGHT FITTING ellk 2... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 2... EX-EMERGENCY LIGHT

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS EX-FLUORESCENT LIGHT FITTINGS Cooper Crouse-Hinds 00 - all rights reserved EX-LIGHT FITTING ellk... MAIN FEATURES.0 EX-LIGHT FITTING ellk... EX-POLE MOUNTED LIGHT FITTING ellm....0. EX-EMERGENCY LIGHT

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

CEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings. EATON 1.2.1

CEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings.  EATON 1.2.1 CEAG Products Main Catalogue Part 1 Chapter Ex-Light fittings www.crouse-hinds.de EATON 1..1 1.. EATON www.crouse-hinds.de Ex-Light fittings Table of contents.1 Information on Ex-linear light fittings

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S

E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 1 E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 2 4 5 6 8 EX- CEILING LIGHT FITTINGS EX- PENDANT LIGHT FITTINGS 4.41 4. EX- FLOODLIGHTS EX- VESSEL LIGHT FITTING

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

EX-CONTROL AND DISTRIBUTION SYSTEMS

EX-CONTROL AND DISTRIBUTION SYSTEMS EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

CEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights. EATON 1.4.1

CEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights.  EATON 1.4.1 CEAG Products Main Catalogue Part 1 Chapter Ex-Ceiling, pendant light fittings and floodlights www.crouse-hinds.de EATON 1..1 2 1..2 EATON www.crouse-hinds.de Ex-Ceiling, pendant light fittings and floodlights

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Installation Equipment

Installation Equipment Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

GB-distribution boxes and enclosures

GB-distribution boxes and enclosures GBdistribution boxes and enclosures, polyester, to European Standards (ATEX) Features þ ATEXcertified þ BASEEFAcertified þ Large range of s including BARTEC, Weidmüller, Phoenix þ Different enclosure s

More information

ST T indoor batten fluorescent light fitting. USE ADVANTAGES IP20

ST T indoor batten fluorescent light fitting. USE ADVANTAGES IP20 ... indoor batten fluorescent light fitting. USE The light fitting is suitable for assembly and production shop floors, supermarkets, warehouses and hallways. The light fitting is suitable for composing

More information

Z7A. Load cells. Special features. Data sheet. Wiring code

Z7A. Load cells. Special features. Data sheet. Wiring code Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust

More information

4.35. Accessories for Ex-Ceiling light fitting AB 80. Guard GAB 80 NOR Accessories for Ex-Pendant light fitting AB 50

4.35. Accessories for Ex-Ceiling light fitting AB 80. Guard GAB 80 NOR Accessories for Ex-Pendant light fitting AB 50 EV... 0-0 ZM EVI 00 UD AB 0 IU AB 0. Accessories for Ex-Ceiling light fitting AB 0 Guard GAB 0 NOR 000 00 0 Accessories for Ex-Pendant light fitting AB 0 Ceiling bracket with screws / AS.EV/AB NOR 000

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315 D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2 Linear actuator Econom 2 Our intelligent model: Econom 2 Econom 2 Linear actuators Econom 2 Description Applications Facts The users of the Econom 2 come from many different industries: From architects

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure

More information

LuxSpace recessed high efficiency, visual comfort and a stylish design

LuxSpace recessed high efficiency, visual comfort and a stylish design Lighting LuxSpace recessed high efficiency, visual comfort and a stylish design LuxSpace Mini, recessed Customers are looking to optimize all their resources, and that means not just their running costs

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

ct m ive p 5/EC Thermal cut-outs

ct m ive p 5/EC Thermal cut-outs RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

EXPLOSION PROOF ATEX LUMINAIRE

EXPLOSION PROOF ATEX LUMINAIRE info@nextgenerationled.be www.nextgenerationled.be Tel + 32 53 71 09 42 EXPLOSION PROOF ATEX LUMINAIRE Properties n Lifespan L80 %: > 50.000 hours n Atex directive 94/9 EC n Zone 2 and 22 n IP klasse :

More information

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

Più alto 3d flat»cc«datasheet

Più alto 3d flat»cc«datasheet Datasheet LED wall / ceiling spotlight with single-sided light output. Optionally available with optics (Più) or flat with internal (Più R). Version with flat base for fitting on hollow ceiling or flush-mounted

More information

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013 industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE

PHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE Product description Luminous flux: 5, lm per module Square module one module per luminaire nonselv (HV) and SELV (LV) variants High colour rendering index CRI 8 Small colour tolerance (MacAdam 4) Efficacy

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

PHOS 15 LED PROJECTOR

PHOS 15 LED PROJECTOR PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact 853 LED beacon is particularly versatile. With an

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing

More information

Page 1 of 16 Issue No. 0 of IECEx TUN X

Page 1 of 16 Issue No. 0 of IECEx TUN X Page 1 of 16 IECEx TR: DE/TUN/ExTR10.0002/00 IECEx QAR: DE/TUN/QAR06.0006/02 File reference: 10 204 55781-annex File reference: General product information: The electro pneumatic positioner SIPART PS2

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

CLUSTERLITE CONTENTS MEGAMAN

CLUSTERLITE CONTENTS MEGAMAN CONTENTS Specifications for... 2.1 Maximum Temperature Declaration... 2.3 Lumen Maintenance Curve... 2.4 Vs. Temperature... 2.6 Run-up Time... 2.8 Specifications for Power Supply... 2.1 Line Drawings for

More information

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

für for T5-Lampen fluorescent in Multi-Lamp-Technologie Dimmbare Dimmable electronic elektronische control Vorschaltgeräte gear für for T-ampen fluorescent in Multi-amp-Technologie lamps in technology M-tec Performance characteristics Dimmable ECG in Multi-amp

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic Uready2apply DLA G1 SNC China domestic uready2apply DLA Product description Downlight module suitable for direct installation in ceilings (ready2apply) Module with integrated electronics and heatsink Light

More information

Field mounted Temperature Transmitter TF212/TF212-Ex

Field mounted Temperature Transmitter TF212/TF212-Ex Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

Tunable White LED compact

Tunable White LED compact Module TW DLE G2 60mm 3000lm 927-965 DLE modules Product description module for Downlights with adjustable colour temperature from 2,700 to 6,500 K at constant luminous flux High colour rendering index

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G4 16mm 125lm ADV Module LLE ADVANCED Product description Ideal for compact linear luminaires designs Homogenous illumination thanks to small package distance SELV module the single module has

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,92 lm at tp = 65 C High efficacy up to 147 lm/w

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50 w LED light engine / OLED Product description For spotlights and downlights Housing with Snap-On feature for easy reflector mounting Luminous flux up to 2,51 lm at tp = 65 C High efficacy up to 124 lm/w

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information