DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
|
|
- Steven Warren
- 6 years ago
- Views:
Transcription
1 DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from mbar up to bar Output signals -wire:... 0 ma / -wire: V others on request Special characteristics hygienic version diaphragm with low surface roughness CIP / SIP cleaning up to 50 C vacuum resistant Optional versions IS-version Ex ia = intrinsically safe for gases and dust SIL according to IEC 6508 / IEC 65 in Hastelloy or Tantalum The pressure transmitter DMP P was designed for use in the food / beverage and pharmaceutical industry. The compact design with hygienic versions makes it possible to achieve an outstanding performance in terms of accuracy, temperature behavior and long term stability. The modular construction concept allows a combination of various process connections with different filling fluids and a cooling element. Several electrical connections complete the profile of DMP P. Preferred areas of use are Food and Beverage Pharmaceutical Industry Material and test certificates inspection certificate. according to EN 00 test report. according to EN 00 cooling element for media temperatures up to 00 C 7-06 BD SENSORS GmbH BD-Sensors-Straße Tel +9 (0) 9 5 / D Thierstein Fax +9 (0) 9 5 / 98 - info@bdsensors.de
2 DMP P Input pressure range Nominal pressure gauge Nominal pressure abs Overpressure Burst pressure Nominal pressure gauge / abs Overpressure Burst pressure Vacuum resistance P N > bar: unlimited vacuum resistance P N bar: on request consider the pressure resistance of fitting and clamps Output signal / Supply -wire:... 0 ma / V S = 8... V DC SIL-version: V S = 8 V DC Option IS-protection -wire:... 0 ma / V S = V DC SIL-version: V S = 8 V DC Options -wire -wire: ma / V S =... 0 V DC V / V S =... 0 V DC Performance Accuracy standard: nominal pressure < 0. bar: ± 0.5 % FSO nominal pressure 0. bar: ± 0.5 % FSO option: nominal pressure 0. bar: ± 0.5 % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: < 0 msec -wire: msec accuracy according to IEC limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Nominal pressure P N - 0 < Tolerance band [% FSO] ± 0.75 ±,5 ± 0.75 in compensated range [ C] Permissible temperatures medium: C for filling fluid silicone oil C for filling fluid food grade oil electronics / environment: C storage: C Permissible temperature medium filling fluid silicone oil overpressure: C vacuum: C 5 for cooling element 00 C filling fluid food grade oil overpressure: C vacuum: C 5 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 60 minutes with a max. environmental temperature of 50 C 5 also for P abs bar Electrical protection Short-circuit protection Reverse polarity protection Electromagnetic compatibility Mechanical stability Vibration according to DIN EN Shock according to DIN EN Filling fluids Options permanent no damage, but also no function emission and immunity according to EN 66 G /": 0 g RMS ( Hz) G /": 500 g / msec others: 0 g RMS (5 000 Hz) others: 00 g / msec silicone oil food grade oil, compliant with CFR (Mobil SHC Cibus ; Category Code: H; NSF Registration No.: 500) others on request Materials Pressure port stainless steel.5 (6 L) others on request Housing stainless steel.0 (6 L) Option compact field housing stainless steel.05 (0), cable gland brass, nickel plated others on request Seals (media wetted) Optional Optional Media wetted parts FKM (recommended for medium temperatures 00 C) FFKM (recommended for medium temperatures > 00 C) Clamp, dairy pipe, Varivent : without stainless steel.5 (6 L) Hastelloy C-76 (.89) pressure port, seal, diaphragm others on request Tantalum on request pressure and level
3 DMP P Explosion protection (only for 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX 9-DMP P zone 0: II G Ex ia IIC T Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing Ambient temperature range in zone 0: C with p atm 0.8 bar up to. bar in zone or higher: C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL 6 according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight min. 00 g (depending on process connection) Installation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) Operational life CE-conformity ATEX Directive 6 only for 0 ma / -wire Wiring diagrams -wire-system (current) p supply + > 00 x 0 6 pressure cycles EMC Directive: 0/0/EU 0//EU -wire-system (current / voltage) supply + p V S V S supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 00 Supply + Supply Signal (only -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) Mx / metal (-pin) Shield ground pin 5 field housing IN + IN - OUT+ cable colour (IEC 60757) wh (white) bn (brown) gn (green) gnye (green-yellow) standard option ISO 00 Binder Series 7 Mx -pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 7 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 8 universal field housing stainless steel.0 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 7 standard: m PVC cable without ventilation tube (permissible temperature: C) 8 different cable types and lengths available, permissible temperature depends on kind of cable
4 DMP P Mechanical connection (dimension in mm) Option Option G/" flush DIN 85 9 G /" flush DIN 85 G" flush DIN 85 with ISO 00 with ISO 00 G/" flush G" flush G" cone cooling element 00 C with radial o-ring 9 with radial o-ring (PN bar) with ISO Varivent dairy pipe (DIN 85) Clamp (DIN 676) PN 5 bar with ISO 00 with ISO 00 dimension in mm size DN 5 DN 0 DN 50 A 5 B P N 0,5 0 SIL- and SIL-Ex version: total length increases by 6.5 mm! metric threads and other versions on request 9 possible only for P N bar 0,5 0 0,5 5 dimension in mm size ¾ DN 5 DN DN 50 A 5 B P N ,5 6 * higher pressure ranges on request BD SENSORS GmbH The specifications given in this document represent the state of engineeringat the time of publishing. We reserve the right to make modifications to the specifications and materials. DMPP_E_086 pressure Tel +9 and (0) level 9 5 / Fax +9 (0) 9 5 / 98 - info@bdsensors.de
5 DMP P Pressure gauge absolute Input X Output 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 0 ma / -wire SIL 0 ma / -wire SIL with Intrinsic safety 0 ma / -wire E S ES Accuracy standard for P N 0. bar 0.5 % standard for P N < 0. bar 0.5 % 5 option for P N 0. bar 0.5 % Electrical connection Male and female plug ISO 00 Male plug Binder series 7 (5-pin) Cable outlet with PVC-cable Cable outlet Male plug Mx (-pin) / meta Compact field housing stainless stee stainless steel T A 0 T R 0 M Mechanical connection G/" with flush 5 welded diaphragm (DIN 85) Z 0 0 G/" with flush welded diaphragm (DIN 85) Z 0 G" with flush welded diaphragm (DIN 85) Z G" DIN 85 with rad. o-ring 6 and flush diaphragm Z 5 7 G/" DIN 85 with rad. o-ring 5 and flush diaphragm Z 6 G " cone Clamp DN 5 / " (DIN 676) / A Clamp DN / /" (DIN 676) / A Clamp DN 50 / " (DIN 676) / A Clamp /" (DIN 676) / A Dairy pipe DN 5 (DIN 85) Dairy pipe DN 0 (DIN 85) Dairy pipe DN 50 (DIN 85) Varivent DN 0/50 / A K C 6 C 6 C 6 C 6 9 M 7 M 7 5 M 7 6 P 9 9 Stainless steel.5 (6L) Tantalum T consult Hastelloy C-76 (.89) H Seals for clamp, dairy pipe, Varivent : without 0 for inch thread - standard: FKM for inch thread - option: FFKM 7 Filling Fluids silicone oil food grade oil (FDA) / A Special version standard with cooling element up to 00 C / A absolute pressure possible from 0. bar standard: m PVC cable without ventilation tube (permissible temperature: C), others on request Ordering code DMP P cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable The cup nut has to be mounted by production of pressure transmitter with electrical connection field housing and mechanical connection dairy pipe. The cup nut has to be ordered as separate position. 5 possible only for P N bar 6 possible only for P N bar Varivent is a brand name of GEA Tuchenhagen GmbH, Hastelloy is a brand name of Haynes International Inc BD SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.
DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationTÜV NORD CERT GmbH Am TÜV 1 30519 Hannover IECEx Certification Body Page 1 of 3 Issue No. 2 of IECEx TUN 06.0014 X IECEx TR: File reference: DE/TUN/ExTR06.0059/02 07 203 554192 IECEx QAR: DE/QAR/TUN/06.0002/00
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationExchangeable measuring insets SensyTemp TSA101
Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationField mounted Temperature Transmitter TF212/TF212-Ex
Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationall stainless steel transducer multimedia compatibility
all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low
More informationTABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic
TABLE OF CONTENT ATEX Certificate Explosionproof sensors from Pulsotronic code How to read sensor designations Circuit diagrams Connection according to EN 606 Sensors Cylinder M8 Cylinder M Cylinder M8
More informationRing-Torsion Load Cells RTB
Ring-Torsion Load Cells RTB % PTB & OIML approved as suitable for trade use (up to 6000 d and 7500 d in case of multi-divisional scales) % High accuracy, even for very small utilisation ranges (down to
More informationFlow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.
FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended
More informationReflex-Radar BM 100 A
KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More informationBTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters
FETURES to, to differential pressure...6 or... m Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDI CMPTIBILITY Pressure inlet: Non-corrosive,
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationFlow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationTABLE OF CONTENT. Designation code. Circuit diagrams. Sensors. How to read sensor designations. Connection according to EN
TLE OF CONTENT code How to read sensor designations Circuit diagrams Connection according to EN 609752 Sensors Cylinder G6,5 Cylinder M8 Square Q8 Cylinder M2 Square Q2 Cylinder M8 Cylinder G20 Cylinder
More informationHMA Series Amplified pressure sensors
FEATURES 00 to 0 bar, to 0 psi gage or differential pressure Increased media compatibility Analog output Precision ASIC signal conditioning Calibrated and temperature compensated 2 SIL and DIP housings
More informationv = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes
with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating
More informationTABLE OF CONTENT Designation code
TLE OF CONTENT code How to read sensor designations Circuit diagrams according to EN 60752 Functional description Operating mode of capacitive sensors 5 pplications pplication areas of capacitive sensors
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation
TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationCoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter
Data Sheet DS/FCB400/FCH400-EN Rev. D CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter
Data Sheet DS/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter High precision measurement of mass and volume flow, density, temperature and concentration with
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationAT9000 Advanced Transmitter Differential Pressure Transmitters
No. SS2-GTX00D-0100 (Rev.8) AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance
More informationANNEX to IECEx Certificate
ANNEX to IECEx Certificate Certificate No.: IECEx ZLM 11.0001X Issue No.: 0 Date of Issue: 2011-09-14 Type designation code EDP300 xx * * * * * ** ** ** ** xx ** ** ** ** ** ** ** ** Limit Switches: without,
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationVD1 CLC. Small Valves DIN-range with a higher k v -value
0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationCertificate No.: IECEx BVS issue No. 1 Annex Page 1 of 8 Subject and Type
Certificate No.: IECEx BVS 12.0066 issue No. 1 Page 1 of 8 Subject and Type VEGAFLEX FX81(*). I * * ** * * * * * * * Certificates: X = no, M - yes adjustment / indication module PLICSCOM X = without: A
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationLoad Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B
Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100
More informationDRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories
Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationDRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories
Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More informationTemperature sensors SensyTemp TSP311, TSP321, TSP331
Contents Data Sheet Temperature sensors SensyTemp TSP311, TSP321, TSP331 Modular system - Measuring inset, thermowell, extension tube, connection head, transmitter - Supports numerous configurations Exchangeable
More informationTecnología en Electrónica y Control SRL Ficha Técnica
Tecnología en Electrónica y Control SRL Ficha Técnica Caudalímetros Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas
More information