Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
|
|
- Loren Walsh
- 5 years ago
- Views:
Transcription
1 Flow sensors Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
2 For industrial applications Volumetric flow sensor efector mid. High-precision measurement, display and signalling of liquid media. Decentralised detection and monitoring of liquid media. Ideal in widely branched cooling systems, e.g. weld - ing lines. The volumetric flow sensor efector mid detects very small deviations from the specified volumetric flow quantity, for example for leaks, and monitors at the same time the temperature of the cooling water. This guarantees process safety and quality. Coolant monitoring Cooling water monitoring Condition-based maintenance. Monitoring of conductive liquids. The diagnostic functionality of efector mid, e.g. analogue outputs, binary limit values, consumed quantities during the specified period or temperature mo n - itoring in the medium, enables the reliable operation of cooling cir - cuits and systems. Due to the contin - uous monitoring the sensor can be perfectly integrat - ed into the condi- tion-based maintenance concepts. This enhances the reliability of the plant; uptime is increased. Expen - sive consequential damage resulting from lack of cool - ant is prevented. By integration into a real-time-maintenance concept maintenance can be implemented at the right time, in the right place, using the right material and oper - ators. The magneticinductive volumet - ric flow sensor is suitable for monitoring conductive media. The media have a different electrical conduc - tivity. efector mid measures liquid media from a conductivity of > 20 μs/cm. industrial water electrical conductivity sea water (salt) water glycol mixtures water-based coolants drinking water
3 efector mid the reliable and lowcost solution for monitoring the exact supply and consumption of liquids in industrial processes. Due to the measuring range of 0 to 25 l/min and an accuracy of ± 2 % of the measured value the unit can be used in a wide range of applications. Volumetric flow in the oppo - site direction is also indicated. Photo reference Induction hardening: R. Rieker GmbH, Leingarten Wafer production: centrotherm thermal solutions GmbH+Co KG, Blaubeuren Cooling process optimisation Water supply documentation alphanumeric display switch point indication programming buttons Compact, informative and easy to install. Measuring length and electronics are integrated into a robust and compact housing. So otherwise usual inlet and outlet pipe lengths can be reduced to a minimum. Pressure loss is negligible. Four-digit alphanumeric display for information on site: current volumetric flow, accumulated total quantity and medium temperature. l/min or m 3 /h can be selected as the unit of mea - surement. Two LEDs indicate the switch points. Mounting via R 1/2 or R 3/4 adapter ensures easy installation in the pipe.
4 1 2 Technical data volumetric flow sensor efector mid Application area conductive liquids (conductivity: 20 μs/cm / viscosity: < 70 mm 2 /s at 40 C) Electrical design Connection DC PNP/NPN 4-wire DC PNP 4-wire Output 1 Output 2 normally open / normally closed programmable or pulse normally open / normally closed programmable or analogue ( ma / V, scalable) G 1/2 male thread analogue ( ma) Process connection Order no. SM6000 SM6050 Operating voltage [V] DC* Current rating [ma] 2 x 200 Short-circuit protection, pulsed 2 x 200 Reverse polarity, overload prot. 2 x 200 Analogue output ma / V ( ma: max: 500 / V: min Ω) Flow monitoring Measuring range [l/min / m 3 /h] / Measurement error [%] ± (2 % measured value % VMR) Setting range [l/min / m 3 /h] Set point, SP Analogue start point, ASP Analogue end point, AEP Start-up delay [s] / / / Temperature monitoring Measuring range [ C] Measurement error [ C] ± 2.5 (Q > 1 l/min) Setting range [ C] Set point, SP Analogue start point, ASP Analogue end point, AEP Pressure resistance [bar] 16 Medium temperature [ C] Display unit Output status Measured values Programming Protection Housing materials Sensor materials Connection 6 LEDs green (l/min, m 3 /h, m 3, 10 3, C) 2 LEDs yellow 4-digit alphanumeric display 4-digit alphanumeric display IP 67, III stainless steel (316S12); stainless steel (316S16); PBT-GF 20; EPDM/X (Santoprene) stainless steel (316S12); PEEK (polyetheretherketone); FKM M12 connector; gold-plated contacts *to EN50178, SELV, PELV SM6000 Sockets Description Order no m PUR, M12 angled, without LED EVC004 5 m PUR, M12 angled, without LED EVC005 G G 1 2 Accessories (selection) Description Order no. 16 M12 x1 M12 x1 Adapter G 1/2 - R 3/4 Process connection G 3/4 flat seal Adapter G 1/2 - R 1/2 Grounding clamp E40189 E40199 E40196
5 Ensuring product quality and plant up-time. Volumetric flow sensor efector mid: Simultaneous monitoring of volumetric flow quantity and temperature of conductive liquids. Functionality and precision at the right price. Local indication of the current volumetric flow quantity, total quantity and temperature. For external evaluation: Switching, pulse and ana - logue outputs for signal and control tasks. Less cost: Setting and monitoring of cooling circuits for optimum performance. More safety: Immediate detection of even very small leaks. High transparency: Counting and allocation of consumed quantities. Exactly right: Exact determination of liquid quantities. V M E Magnetic-inductive flow metering. The volumetric flow sensor is based on Faraday s principle of induction. The conductive medium flowing through a pipe in a magnetic field generates a voltage which is proportional to the flow velocity or volumetric flow quantity. This voltage is tapped via electrodes and M = magnet E = electrodes V = flow velocity M converted in the evaluation electronics. As the pipe cross-section is defined, the volu met ric flow quantity can be determined exactly. No moving components are used, therefore the system works reliably, wear and maintenance free.
6 visit our website: Overview ifm main catalogues: Position sensors and object recognition Inductive sensors Capacitive sensors Magnetic sensors, cylinder sensors Safety technology Valve sensors Photoelectric sensors Object recognition Encoders Evaluation systems, power supplies Fluid sensors and diagnostic systems Level sensors Flow sensors Pressure sensors Temperature sensors Diagnostic systems Evaluation systems, power supplies Over 70 locations worldwide at a glance at Bus systems Bus system AS-Interface Power supplies Identification systems DataMatrix code-reading systems RF-identification systems Power supplies Control systems Control systems for mobile vehicles ifm electronic gmbh Teichstraße Essen Tel. +49 / 0201 / Fax +49 / 0201 / info@ifm.com ifm article no We reserve the right to make technical alterations without prior notice. Printed in Germany on non-chlorine bleached paper. 02/08
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5
More informationOperating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014
Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationOperating instructions Magnetic-inductive flow meter. SM6x01 SM7x01 SM8x / / 2015
Operating instructions Magnetic-inductive flow meter UK SM6x01 SM7x01 SM8x01 80223585 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4
More informationOperating instructions Vortex flow meter. SVxxx / / 2015
Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More information14:1400 (0206) KRAL Volumeter - OMG
14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationOperating instructions Magnetic-inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01
Operating instructions Magnetic-inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01 UK 80224865 / 00 02 / 2018 Contents 1 Preliminary note...4 2 Safety instructions...4 3 Functions and
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationCS Series. Capacitance Type. Type. Proximity Sensor. Features
INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable
More informationUltrasonic Gas Flow Meter
P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications
More informationOperating instructions Magnetic-inductive flow sensor SM / / 2010
Operating instructions agnetic-inductive flow sensor 6000 UK 704458 / 00 04 / 2010 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 4 Function...5
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK MIK with frequency-, switching-, analogue output MIKwith digital plug on display Range from liquids, acids
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationOperating instructions Flow rate meter for gases SD / / 2010
Operating instructions Flow rate meter for gases D6100 UK 704844 / 00 07 / 2010 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 4 Function...5
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More informationDeionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies
Deionized Water Latest technology, highest quality, environmentally friendly Water Technologies NaCl OH - Cl - OH - OH - Cl - Anion OH - OH - Resin OH - OH OH - - OH - OH - Na + Na + Cation Resin H + H
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationCCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Oxidising agents such as chlorine or anorganic
More informationTechnical specification FLUXUS F502TE
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationDirect Water Cooled Wirewound Resistor
Direct Water Cooled Wirewound Resistor FEATURES Direct cooling without heatsink Excellent power / volume ratio Multi resistive element option Material categorization: for definitions of compliance please
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationFlow sensor for liquid media type 210
Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationFlow sensor for liquid media type 230
Flow sensor for liquid media type 0 Flow range.8... 0 l/min Nominal diameters DN 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the Kármán vortex trail. You can choose
More informationOperating instructions Magnetic-inductive flow meter SM2001 SM / / 2014
Operating instructions Magnetic-inductive flow meter SM2001 SM9001 UK 706341 / 00 05 / 2014 Contents 1 Preliminary note...5 1.1 Symbols used...5 1.2 Warning signs used...5 2 Safety instructions...5 3 Functions
More informationLoad Washers. Force kn until kn. Type 9101A A
Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More information50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC
/ Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.
More informationSensors for pressure control OsiSense XMLR
Sensors for pressure control LR Catalogue Simply easy! TM Contents Sensors for pressure control LR General presentation........................ pages 00/ and 00/ Presentation..........................................
More informationELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina
ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT By Dr. Crainic Monica Sabina Luxten Lighting Company AEM Branch Office Gas and Water Meters Research Department 26 Calea Buziaşului300693 Timişoara
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationTABLE OF CONTENT Designation code
TLE OF CONTENT code How to read sensor designations Circuit diagrams according to EN 60752 Functional description Operating mode of capacitive sensors 5 pplications pplication areas of capacitive sensors
More informationFlow sensor type 236 for liquid media
Flow sensor type 6 for liquid media Flow range 0.9... 0 l/min Nominal diameters DN 8 / 0 / / 0 / / Temperature measurement -0... + ÀC The type 6 is based on the type 0 but incorporates a brass housing.
More informationOscillation Flow Meter for Gases
Oscillation Flow Meter for Gases measuring monitoring analysing Measuring ranges: 0.2 to 000 m 3 /h air pmax: PN 0, tmax: 0 C Connection: flange DN 25 DN 00 : Cast Iron, steel or stainless steel Accuracy:
More informationFlow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationEPIV electronic pressure-independent characterised control valve EPIV
electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationSensors and Transducers. mywbut.com
Sensors and Transducers 1 Objectives At the end of this chapter, the students should be able to: describe the principle of operation of various sensors and transducers; namely.. Resistive Position Transducers.
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationOperating instructions Compressed air meter SD / / 2013
Operating instructions Compressed air meter D6000 UK 80004726 / 00 10 / 2013 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 4 Function...5 4.1
More informationApplicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.
TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationOperating instructions Volumetric flow sensor SQ / / 2012
Operating instructions Volumetric flow sensor Q0500 UK 706211 / 00 05 / 2012 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 4 Function...5 4.1
More informationBy-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can
" " ' " ' / The magnetic field which is in the ball or cylindrical floats actuates very small reed contacts through the wall of a guide tube and these pick up an uninterrupted measuring-circuit voltage
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationHeat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97
Heat Meter WR 200-D electronic computing device for heat quantity measuring Heat transfer medium water steam Any flow sensor with analog signal connectable 2 temperature inputs for Pt100 in four-wire circuit
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationOperating instructions Compressed air meter SD / / 2012
Operating instructions Compressed air meter D5000 UK 706091 / 01 03 / 2012 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...4 4 Function...5 4.1 Processing
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationGear Wheel Flowmeter for viscous liquids Model DZR. (option 3):
Gear Wheel Flowmeter for viscous liquids measuring monitoring analysing DZR easuring range:. -... 3-7 l/min Accuracy: ±.3... ±1% of reading p max : bar t max : 1 C Orocess O connection: G ⅛, G ⅜, G ½,
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán
More informationPhysioCare Concept improved. The feeling of a new philosophy
PhysioCare Concept improved The feeling of a new philosophy Intuitive operation Eppendorf Reference (fix), Reference (adjustable-volume) What's new? TÜV approved user-friendliness Optimized pipetting force
More informationLABOTRON EXTRACTION & SYNTHESIS 2450 MHz
LABOTRON EXTRACTION & SYNTHESIS 2450 MHz The LABOTRON TM series is the generic name for a ground breaking range of integrated reactor and microwave transmission systems especially designed to carry out
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationWatercooled RF Power Pot Capacitors External Cooling System
Watercooled RF Power Pot Capacitors External Cooling System FEATURES High voltage, current, and power ratings Compact design reduces terminal self inductance and permit operation up to higher frequencies
More informationThermal Mass Flow Meter for Gases
Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving
More informationMass Flow Meter and Controller
ass Flow eter and Controller for Gases measuring monitoring analysing asuring range: 0-10 m N /min...0-500 N /min ccuracy: ±1.5% f.s. pmax 35 bar; tmax 50 C nalogue output: 0-5 V or 4-20 m Digital display
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationPhysioCare Concept improved. The feeling of a new philosophy
PhysioCare Concept improved The feeling of a new philosophy Intuitive operation Eppendorf Reference (fix), Reference (adjustable-volume) What's new? TÜV approved user-friendliness Optimized pipetting force
More informationElectronic pressure-independent characterised control valve EPIV
Electronic pressure-independent characterised control valve Table of contents The electronic characterised control valve () Project planning 4 Selection and dimensioning 5 Constant flow volume V 5 Valve
More informationOne-hand ph/temperature measuring instrument
One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable
More informationGlobe Valve, Metal. Sectional drawing. *see information on working medium on page 2
Globe Valve, Metal Construction The GEMÜ pneumatically operated /-way valve has a robust low maintenance aluminium actuator. The valve spindle is sealed by a self-adjusting gland packing providing low
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationSize A DIN EN
Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female
More informationVersaFlow Ultrasonic clamp-on Flowmeter Specifications
VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done
More informationTABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic
TABLE OF CONTENT ATEX Certificate Explosionproof sensors from Pulsotronic code How to read sensor designations Circuit diagrams Connection according to EN 606 Sensors Cylinder M8 Cylinder M Cylinder M8
More informationDVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C
Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT
More informationApplication Your benefits
Technical Information CCS140 and CCS141 Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 flow assembly Application Oxidizing agents such as chlorine or anorganic
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationW 34: Sensor technology that does justice to demanding requirements
KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to
More informationOperating instructions Compressed air meter SD / / 2013
Operating instructions Compressed air meter D8001 UK 80004720 / 00 10 / 2013 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 4 Function...5 4.1
More information