Field mounted Temperature Transmitter TF212/TF212-Ex
|
|
- Thomasine Glenn
- 5 years ago
- Views:
Transcription
1 Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote signalling units ( Ω, Ω) Voltages, mv (-...+ mv) Output PROFIBUS PA profile V.0, type A and B Bus design acc. to IEC 8-,. kbit/s Electrical isolation (I/O) Digital, long-term solid processing of measuring values Customer-specific linearization Continuous sensor and self-monitoring Approvals for explosion protection Intrinsically safe II () G EEx ia IIC T Flameproof ATEX Dust-explosionproof ATEX Input functionality or channels Redundancy Average value Differential value EMC acc. to EN 008- and NE Reserve voltage protection and solid bus current limitation Parameterization DTM for FDT and. interface and DSVxx (SMART VISION) Siemens Simatic PDM driver for TF/TF P R O F I PROCESS FIELD BUS B U S Excellent long term stability Temperature linear output signal Enhanced self diagnostics
2 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Technical data Output Digital output signal PROFIBUS PA profile V.0, type A and B Transmission rate (baud rate). kbit/s Nominal current consumption.8 ma Max. current in case of device error ma Damping (programmable) t = s Input Thermocouples Types B, C, D, E, J, K, L, N, R, S, T, U Voltages - mv...+ mv Sensor monitoring current 00 µa Input resistance MΩ Input filter 0/0 Hz Internal reference junction Pt 00, programmable Resistance (temperature linear) Resistance thermometer Pt 0...Pt 00...Pt 000 Resistance Ω/ Ω Maximum line resistance (R w ) per core < Ω Measuring current 00 µa Sensor short-circuit < Ω (for RTD) Sensor break > MΩ Standard IEC 8- Input element Measuring range Basis Sensor Measuring error Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N W, ASTME 998 Thermocouple type C Thermocouple type D DIN 70 Thermocouple type L Thermocouple type U IEC 7 ) Resistance thermometer Pt 00 Resistance thermometer Pt 000 Resistance thermometer Pt 00/PT C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) DIN 70 ) Resistance thermometer Ni C ( F) 0. K Resistance -, -, -wire Ω/ Ω 0.0 Ω/0. Ω Voltage mv...+ mv 0 µv 0. K 0. K 0. K 0. K 0. K 0. K 0. K 0. K 0. K 0. K ) a = ) a = 0.008
3 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Power supply (at transmitter terminals) Supply voltage (poling protected) Non-Ex-application U s = 9... V DC For Ex-Application, max. U i = V DC General characteristics Rise time < 0... s Vibration resistance Vibration in operation Electrical isolation (I/O). kv Environment conditions g nach DIN IEC 8T.- Ambient temperature range C Transport and storage temperature C Relative humidity < 00 % (00 % humidtiy with isolated terminals only) Condensation Permitted Influences Influence of ambient temperature (related to C) Pt 00 ± 0 ppm/k related to 00 C Thermocouple ± 0 ppm/k related to the defined thermocouple measuring range (IEC 8) Characteristics at rated conditions acc. to IEC 770, related to C) Measuring error incl. characteristic deviation Pt 00 (within range C) ± 0. K resistance measurement Ω ± 0.0 Ω Ω ± 0. Ω Thermocouple e. g. type K ± 0. K voltage measurement mv ± 0 µv Additional influence of the internal reference junction Pt 00 DIN IEC 7 cl. B Mechanical construction Housing material aluminium / stainless steel Color (EPOYXY) light grey (RAL 900) Weight.0 g (without accessories) Electrical connection Thread M0 x. / NPT, / NPT, / GK Cable glands (cable,...8,7 mm) see ordering information Ground screw ext./int. mm M /. mm M Terminals. mm, screw terminals
4 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Explosion protection Intrinsically safe (ATEX) Marking II () G EEx ia IIC T EC-Type-Examination certificate ZELM 99 ATEX 00 Temperature class T/T < 0 C/8 C Suitable for connceting to fielbus systems according to FISCO model Supply circuit Output [ia] Input [ia] Max. voltage U i = 7. V U o =.9 V Short-circuit current I i = 0 ma I o = 7 ma Max. power P i <. W P o < mw Internal inductance L i < 0 µh neglectable Internal capacitance C i =. nf neglectable Flameproof (ATEX) Marking II G EEx d IIC T Temperature class T/T/T <0 C/ C/8 C EC-Type-Examination certificate PTB 99 ATEX X Dust-explosionproof (ATEX) Zone 0: Intrinsically safe type Marking II D IP T C II G EEx ia IIC T EC-Type-Examination certificate DMT 0 ATEX E8 and Zelm 99 ATEX 00 Zone 0: Non intrinsically safe type Marking II D IP T C EC-Type-Examination certificate DMT 0 ATEX E8 Parameterization/structure Type of inputs ( independent channels), measuring range, input filter, damping, alarm function, limit values, compensation for ageing, saving of all data proof against mains failure. Standard parameters (factory setting) Channel Pt 00, -wire circuit L-L/L/H/H-H-Lim = -00 C/-00 C/80 C/80 C Damping 0 s, dimension C Channel Pt 00, -wire circuit L-L/L/H/H-H-Lim = -00 C/-00 C/80 C/80 C Damping 0 s, dimension C Default address Process Control System (PCS) A cyclic communication can be established with all PROFIBUS compatible PCSs. Acyclic communication requires a Master Cl., the communication may be established on the basis of the generic slave (to be in acc. to Profile.0; only standard parameters) or a TF specific driver. Those drivers are available for following PCSs: Freelance 000/Control Builder F (DTM or template) Symphony (Composer via DTM) Siemens (via PDM) Configuration-tools DTM for FDT and. interface and DSVxx (SMART VISION) Siemens Simatic PDM driver for TF/TF Electromagnetic compatibility (EMC) Acc. to NAMUR NE recommendation. With Pt 00 sensor Type of test Degree Standard Burst to signal/ data lines Static discharge contact discharge to: contact plate terminals for supply kv EN EN kv kv Radiated field 80 MHz... GHz 0 V/m Coupling 0 khz - 80 MHz 0 V EN EN EN 000--
5 Z-08 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Block diagram Offset Sensor ; (T) Secondary_Value_ / SV Function Block FB Temperature + Status Transducer Block TB PV=SV: Secondary Value PV=SV: Secondary Value PV=SV - SV: Difference PV=SV - SV: Difference PV=/ x (SV+SV): Average PV=/ x (SV+SV): Average / Redundance Primary_Value / PV Function Block FB Calculated Temperature + Status Sensor ; (T) Secondary_Value_ / SV Function Block FB Temperature + Status Offset Connection diagram + Output Microprocessor Input - K K K - PROFIBUS PA V.0 Reference junction K K K a) b) c) d) e) f) g) h) i) a) Resistance thermometer, -wire circuit b) Resistance thermometer, -wire circuit c) Resistance thermometer, -wire circuit d) Double resistance thermometer, -wire circuit e) Double resistance thermometer, -wire circuit f) Thermocouple g) Double resistance thermometer h) Combination resistance thermometer thermocouple i) Combination thermocouple resistance thermometer Resistance measurement analogos to resistance thermometer circuits a) to f) Voltage measurement analogos to thermocouples circuits f) to i)
6 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Communication/Parameterization Engeneering Tool PROFIBUS PA PROFIBUS DP Z-07 T Line resistance and cable type ) Bus termination Segmentcoupler PC with PROFIBUS DP Boards is_pro Multiboard (ifak) PROFIBOARD (softing) and Software DSVxx (SMART VISION) ) The PROFIBUS standard EN 8- requires the use of shielded bus cables. Please refer to the user manual in regards to the required shielding measures. Dimensional diagram (dimensions in mm) electrical connections thread equipotential bonding screw M lock screw 8 Wall mounting 0 M8 7 0 ~0 8 7 Pipe mounting
7 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Ordering information Catalog No. TF/TF-Ex V- Without explosion protection TF without explosion protection With explosion protection Type of protection: intrinsic safety TF-Ex Zelm / ATEX II () G EEx ia IIC T (Zone ) Type of protection: flameproof TF-Ex d PTB / ATEX II G EEx d IIC T D Type of protection: dust-explosionproof ATEX (Zone 0) TF-Ex DMT/ATEX II D IP T C and S II G EEx ia IIC T (intrinsically safe type) TF-Ex D DMT/ATEX II D IP T C (Non intrinsically safe type) G Display / construction AGLF/AGSF housing without display N Material Aluminum A Stainless steel E Connections with cable screw connections / PA-connector pieces: M0 x. or pressure-proof ) N M-connector for PROFIBUS PA (Weidmüller) and M 0 x. W Thread (without cable-screw-connection) M0 x. /" NPT /" NPT /" GK Mounting field housing without Wall mounting (carbon steel) Wall mounting (stainless steel) " Pipe mounting (carbon steel) " Pipe mounting (stainless steel) Programming Factory standard parameter default address S Channel : Pt00, -wire circuit, damping off, unit C L-L // L / H // H-H = -00 C // -00 C / 80 C // 80 C Channel : Pt00, -wire circuit, damping off, unit C L-L // L / H // H-H = -00 C // -00 C / 80 C // 80 C Customer-specified parameter definition (all parameter without user curve) K Extended customer-specified parameter definition (all parameter including user curve) L ) Metal screw connection EEx e or EEx d (cable-diameter. 8.7 mm) 7
8 Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Accessories Catalog No. Surge / Lightning protection for M0 x. cable -entry-glands, Non Ex-Version Type DPI MD M S 79 Surge / Lightning protection for M0 x. cable -entry-glands, Ex-Version Type DPI MD EX M 79 Device Management Tool DSVxx (SMART VISION) and DTM TF/TF see Data Sheet 0/-.0 EN TF/TF Siemens Simatic PDM.0 + SP device driver can be downloaded free of license costs from Note: Surge/lightning protection is permitted only for ATEX intrinsically safe devices which will be installed in zone or. Measuring circuit of these devices with surge/lightning protection can also be used for zone 0 if allowed in the ATEX approval of this device type The Industrial IT wordmark is a registered or pending trademark of ABB. ABB has Sales & Customer Support expertise in over 00 countries worldwide. The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (09.0) ABB 00 Rev. A ABB Ltd. Salterbeck Trading Estate Workington, Cumbria, CA DS UK Tel: +(0)9-80- Fax: +(0)9-8- ABB Inc. E. County Line Road Warminster, PA 897 USA Tel: Fax: ABB Automation Products GmbH Borsigstr. 7 Alzenau Germany Tel: Fax: CCC-support.deapr@de.abb.com
TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation
TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationTH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation
TH 0 / TH 0-Ex Field mounted temperature transmitter, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation 0/-8.6 EN Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationS95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationExchangeable measuring insets SensyTemp TSA101
Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationCALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%
ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSA101 Exchangeable measuring insets 2 SENSYTEMP TSA101 EXCHANGEABLE MEASURING INSETS DS/TSA101-EN REV. E Measurement made easy Compatible
More informationPhysikalisch-Technische Bundesanstalt
Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (13) S C H E D U L E (14) EC-TYPE-EXAMINATION CERTIFICATE PTB 99 ATEX 2139 X (15) Description of equipment The TH-series measuring transducers
More informationSCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount
20 Programmable 2-Wire Temperature Transmitter, Head Mount Configurable Transmitters Description Each 20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationFlow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationCALYS 80P. Field pressure calibrator with high accuracy 0.01%
Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationCapacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z
Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationWelcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher
Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationTÜV NORD CERT GmbH Hanover Office Am TÜV Hanover Germany. Testing Laboratory Explosion Protected Equipment and Monitoring Devices
Page 1 of 5 Electrical data FMP 40-1...B., FMP 40-1 K., FMP 40-2 B., FMP 40-2 K., FMP 40-4 B., FMP 40-4 K., FMP 40-5 B., FMP 40-5 K., FMP 40-6 B., FMP 40-6 K., FMP 40-8 B., FMP 40-8 K. FMP 45-1..B.., FMP
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationPTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30
eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationModel DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint
Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint Model DS1200-AMT-Ex Dewpoint Hygrometer has been designed
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS
More informationMODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)
Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read
More informationTechnical specification FLUXUS F502TE
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationTemperature sensors SensyTemp TSP311, TSP321, TSP331
Contents Data Sheet Temperature sensors SensyTemp TSP311, TSP321, TSP331 Modular system - Measuring inset, thermowell, extension tube, connection head, transmitter - Supports numerous configurations Exchangeable
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationTSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max
Flap-Type Flowmeter measuring monitoring analyzing TSK Range: 6.6...26.4 to 880...6600 GPM Accuracy: ± 2.5% of Full Scale P max : 580 PSI T max : -40 572 F Connection: Wafer Flange 1.5" 20" ASME Material:,
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationFitting PS P - B - R2
INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable
More informationWake Frequency Calculations Solid Drilled Thermowells
Technical Description TD/TP 002 Issue 1 Wake Frequency Calculations Solid Drilled Thermowells What is a thermowell? A thermowell is a pressure-tight receptacle that protrudes into a pressure vessel. What
More informationPage 1 of 16 Issue No. 0 of IECEx TUN X
Page 1 of 16 IECEx TR: DE/TUN/ExTR10.0002/00 IECEx QAR: DE/TUN/QAR06.0006/02 File reference: 10 204 55781-annex File reference: General product information: The electro pneumatic positioner SIPART PS2
More informationReflex-Radar BM 100 A
KROHNE 09/2001 7.02317.22.00 GR/PRINTO Reflex-Radar The universal TDR level gauge for liquids, solids and interface Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER
ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection
More informationST3000 Series 900 Smart Transmitter Differential Pressure Transmitters
No. SS2-STJ100-0100 (Rev.9) ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters Model STD910/STD920/STD930/STD960/STD921/STD931/STD961 OVERVIEW The ST3000 Smart Transmitter is a microprocessor-based
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationPOINTS OF CAUTION BEFORE USE...
INSTRUCTION MANUAL NPN DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 6 points each (-I/-II, e-con connector) MODEL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Product availability : Stock - Normally stocked in distribution facility Price* : 1485.00 USD Main Range of
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationSafety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationCertificate No.: IECEx BVS , issue 3 Annex Page 1 of 9
Page 1 of 9 General product information: The Radar-Sensor type VEGAPULS PS6*(*).******** and type VEGAPULS PSSR68(*).******** is used to measure the distance between the surface of combustible dust generating
More informationOPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000
3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER Model : TM-2000 Your purchase of this THERMOMETER marks a step forward for you into the field of precision measurement. Although this THERMOMETER is a
More informationSafety Barriers Series 9001, 9002 Standard Applications
Standard s Analog input with transmitter Smart 9001/51-80-091-141 09949E0 Load of transmitter U N = + 0 V... 35 V I N = 3.6 ma... ma R L ( 350 O U min (I N= 0 ma) U N - 9.5 V 14 V U N ( 3.5 V > 3.5 V Maximum
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power
More informationRing-Torsion Load Cells RTB
Ring-Torsion Load Cells RTB % PTB & OIML approved as suitable for trade use (up to 6000 d and 7500 d in case of multi-divisional scales) % High accuracy, even for very small utilisation ranges (down to
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationUltrasonic Gas Flow Meter
P r o d u c t i n f o r m at i o n FLOWSIC600 Ultrasonic Gas Flow Meter For custody transfer and process applications Analyzers and Process Instrumentation FLOWSIC600 For Custody Transfer and Process Applications
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationRef: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,
Digital Current Transducer HLSR-PW series I P N = 16... 50 A Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000, Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationHAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS
MICRONAS INTERMETALL HAL1...HAL, HAL Hall Effect Sensor ICs Edition May, 1997 1--1DS MICRONAS HAL1...HAL HAL Hall Effect Sensor IC in CMOS technology Common Features: switching offset compensation at khz
More information