1 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation for temperature drifts ma and Voltage outputs Complete range of electrical connections ATEX II 1/2 G, EEx ia IIC T6, T5, T4 CIP/SIP Description The ED 701 is a pressure transmitter available in ma current loop or in voltage output signal versions. This transmitter offers a very high ac cu ra cy over a wide tem per a ture range, an excellent repeatability and very long term sta bil i ty. The piezo-resistive sil i con sensor is anodic bond ed on a very stable glass base, which is attached to a stainless steel con struc tion. This assembly guar an ties an excellent ther mal isolation. The sensor is isolated from the process by a stainless steel diaphragm ( / 316L) and a filling liquid. The electronics are located within the hermetically sealed transmit ter housing which give the ED 701 an excellent re sis tance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only de pends on the choice of the electrical connection. The electronics are a state-of-the-art signal processing unit fitted with a fast micro-controller allowing the com pen sa tion of drift effects due to temperature on the sensor sig nal, over a wide temperature range with a fast response time. The ED 701 is available with a great variety of pres sure and electrical connections to meet all requirements. The elec tri cal connection can be replaced easily and gives ac cess to the Autozero adjustment. The ED 701 is a very flexible transmitter suitable for all types of applications and more specifically for food and beverage, pharmaceutical, and biotech ap pli ca tions. made to measure Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 1

2 Ordering Details digit Pressure connection Male thread G 1 2 EN Male thread G 1 4 EN Male thread M20x1.5 DIN Male thread G 1 2 DIN 3852 with O ring 3 ) 4 Male thread G 1 8 EN Female thread G 1 2 DIN Female thread G 1 4 DIN For assembly with pressure seal 8 Male threa 2-14NPT, ASP N152 A Female threa 4-18NPT, ASP N152 B Male thread UNF E Male thread G1 flush diaphragm cone 3 ) J Male thread G1 flush diaphragm O ring 3 ) K Male thread G 1 2 flush dia. DIN 3852 (Combi Connect) 3, 4 ) L Clamp 21.3, ISO , 4 ) M Clamp DN 33.7/DN 38 (1 1 2 ), ISO ) N Clamp DN 40/DN 51 (2 ), ISO ) P Clamp DN 63.5 (2 1 2 ), ISO ) Q Output signal ma V DC V DC 5 Approvals None 0 ATEX 1 Electrical connection 2 meter shielded cable 3 conductors 1 Fischer Plug (IP 67) 2 ) 2 DIN Binder Plug 3 DIN Plug 4 Bendix 6 pole Plug 5 M12, 4 pole Industrial Plug (IP 67), for add-on cable, see chapter Accessories NPT, cable length 1 m (IP 67) 7 2 meter shielded cable 3 conductors, IP 67 9 Field Housing IP 67 5 ), cable gland brass nickel-plated A Field Housing IP 67 5 ), all stainless steel, cable gland stainless steel B Field Housing IP 67 5 ), cable gland PA C Accuracy 0.4% FS, compensated temperature C 7 ) 1 0.2% FS, compensated temperature C 7, 8 ) 2 0.1% FS, compensated temperature C 7, 8 ) 3 0.4% FS, at specified adjusted temperature for medium temperature 125 C 6 ) A 0.2% FS, at specified adjusted temperature for medium temperature 125 C and 200 C 6 ) B 1) Pressure range up to 20 bar. Maximum pressure depends on clamp fork. Operating temperature must be considered. 2) Cable socket included. 3) See code 10 for O ring selection. 4) Combi Connect and Clamp 21.3 availability: From 1 bar, available with all accuracy ordering code (code 5) From 400 mbar, limited to accuracy ordering code 5 = 1 and A ( 0.4% FS) 5) Cable diameter 5 to 12 mm. 6) For a standard adjustment at 25 C, no optional ordering code is required. For specific temperature adjustment, the optional ordering code /9007/TTTT must be supplied. Refer to options and accessories chapter for further details. Maximum Medium temperature: The maximum medium temperature depends on the applied ambiant temperature. For Tamb 80 C, the maximum allowed medium temperature will be 150 C For Tamb 60 C, the maximum allowed medium temperature will be 200 C For Tamb 40 C, the maximum allowed medium temperature will be 300 C. CAUTION: Not respecting these limits will cause product damage. The compensated temperature range is ± 25 C of the adjusted temperature or 10 C C if the standard calibration applies. If the adjusted temperature is above 125 C or 175 C or 200 C, the compensated temperature range will always be 100 C C or 150 C C or 200 C 250 C respectively, depending on the maximum allowed medium temperature. Code A and B are only available with flush diaphragm pressure connection types, i.e. ordering code 1 = J, K, L, M, N, P, Q 7) Optional code /9007/TTTT applies. The maximum calibration temperature is limited to 125 C. 8) If the calibration temperature is above 80 C, the calibrated temperature lies outside of the compensated range. Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 2

3 Ordering details (continued) digit Pressure units Gauge pressure 3 Absolute pressure 4 Negative gauge pressure 5 Pressure range 1 ) 100 mbar up to 40 bar: gauge pressure See code 500 mbar up to 40 bar: absolute pressure below Wetted parts All Stainless Steel 1 O ring NBR* 5 O ring Viton* 6 O ring EPDM* 7 * See ordering code digit 1 for pressure connections those require an O ring seal Oil filling Silicon 0 FDA approved white oil (Standard) 1 Silicon free / oxygen service (pending) 2 Pressure range details (see chapter Options and Accessories for more) Code Range Code Range Code Range mbar bar psi A A D ) 4 ) D ) 4 ) D ) 4 ) D ) 4 ) D ) D ) H ) 4 ) H ) 4 ) H ) C ) 4 ) C ) A A A ) ) D ) ) H ) ) ) ) 1) Combi Connect and Clamp 21.3 availability: From 1 bar, available with all accuracy ordering code (code 5) From 400 mbar, limited to accuracy ordering code 5 = 1 and A ( 0.4% FS) 2) Valid only for ordering code digit 6, negative gauge pressure (code 5) 3) Not available with pressure connection code M, N, P and Q, according to ordering code digit 1 4) Valid only for ordering code digit 5, accuracy 0.4% FS (code 1) 05D D D D D D D D D D D D D D D D ) 32D ) 70D ) 4 ) 71D ) 4 ) 72D ) 80D ) 60D ) 4 ) 61D ) 4 ) 62D ) 81D ) 82D ) 83D ) Language of certificate and service manual Please specifiy in plain text with the ED 701 ordering information. Documents are available in English, German and French. Per default, certificate and service manual are in German. Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 3

4 Technical data Measurement characteristics Pressure range Gauge pressure mbar, bar Abs. pressure mbar, bar Pressure ranges available within the defined ordering code. Adjustment Auto-Zero function by press-button located behind the electrical plug. Please remove plug to get access. ED 701 must be powered. Overpressure At least 3 times nominal value Accuracy According to ordering code 5 Hyteresis and repeatability 0.05% FS Long term stability 0.2 % FS/year Temperature influence (in compensated range) Accuracy code 5 = 1 ( 0,4% FS) TC zero = 0.2% FS/10K TC Span = 0.15% FS/10K Accuracy code 5 = 2 ( 0.2% FS) TC zero = 0.1% FS/10K TC Span = 0.1% FS/10K Accuracy code 5 = 3 ( 0.1 % FS) TC zero = 0.05% FS/10K TC Span = 0.05% FS/10K Response time %, 25 ms Electrical specification Supply voltage V DC Insolation Resistance >1 GOhm, 500 V DC Load R L < 50 x U B Influence of the Power supply Protected against reverse signal po lar i ty. Operating Temperature limits with FDA white oil (standard) -10 C 125 C, for wetted parts all stainless steel -10 C 125 C, with Viton O ring -10 C 120 C, with EPDM O ring -10 C 80 C, with NBR O ring Operating Temperature limits with silicon oil (alternate option) -30 C 125 C, for wetted parts all stainless steel -20 C 125 C, with Viton O ring -30 C 120 C, with EPDM O ring -20 C 80 C, with NBR O ring Compensated temperature range -10 C C with accuracy code 5 =1 ( 0.4% FS) -10 C C with accuracy code 5=2,3 ( 0.2%FS, 0.1%FS) -10 C C or 25 C around the calibration temperature with accuracy code = A,B ( 0.4%FS, 0.2%FS) Sterilisation Temperature 140 C, 30 minutes Storage Temperature -55 C C For version fitted with O ring seals, refer to operating temperature Ambient temperature (housing) -10 C.. 80 C Materials specification Wetted part Stainless Steel W (fitting body) and W (AISI 316L, diaphragm) Parts not in contact with medium Stainless Steel W (housing), W (AISI 304 connector base) and elec tri cal con nec tor material. Certificate EN B available on request EMC Influence of EMC Less than 0.15% FS Conformity EN , EN , EN 61326, EN Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 4

5 Technical data Environmental specification Humidity According to EN Vibrations According to EN Shocks According to EN Sterilisation Complete device, not powered, only flush diaphragm versions (without O ring seal) and Fischer electrical plug. Process duration 60 minutes, not powered, sterilisation temperature max. 140 C, pressure 3500 mbar. Protection class Rating IP 65 and IP 67, depending on electrical plug. Switch ON time 5 sec. Test Certificate Delivered with the transmitter. Test certificate, 6 points rising at ambient temperature (T amb = 25 C). Physical characteristics Weight Between 223 and 885 g depending of the version. Dimensions See drawings. Mounting Position at calibration time: Vertical Zero setting function The Zero setting function is available directly on the device by removing the electrical plug. The Zero is ac ti vat ed pressing the push button located on the top of the electronic unit. Pressing the Zero button will cause the applied pressure to be considered as zero. This function allows ini tial iza tion of the zero point e.g. in level measurement. Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 5

6 Drawing (all dimensions in mm) DIN plug Code 3 ): 4 Bendix 6 pole plug Code 3 ): 5 Cable 3 conductors IP 65 / IP 67 Code 3): 1 (IP 65) 9 (IP 67) DIN Binder plug Code 3 ): ) Cross reference to ordering code digit 4, electrical connection, see page 2 Code 2 ) Thread l 1 A NPT 20 Code 2 ) Thread d 2 d 3 l 1 l 2 E UNF key 27 key 27 key 27 d 3 l 3 l 2 l l 1 25 l 1 key d 3 d 2 l 2 l 1 23 key 27 d 2 l 1 l 2 23 d 2 Code 2 ) Thread d 2 d 3 l 1 l 2 l 3 1 G G M20x G Code 2 ) Thread l 1 4 G ) Cross reference to ordering code digit 1, process connection, see page 2 Code 2 ) Thread d 2 l 1 l 2 6 G G B NPT Mounting example Seal Pressure port Seal Seal Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 6

7 Drawing (all dimensions in mm) Fischer plug Code 3 ): 2 NPT 3 conductors Code 3 ): 7 M12 industrial plug Code 3 ): 6 Field housing Code 3 ): A, B or C key ) Cross reference to ordering code digit 4, electrical connection, see page 2 Only for ordering code digit 5 = A and B 61.5 l 4 Code 2 ) l 4 K, J 48 L 50 M, N, P, Q key 41 l 1 l 2 12 key l 2 l key l 2 l 1 12 d 2 Membrane l 1 d 2 d 2 d 2 Code 2 ) Thread d 2 l 1 l 2 K G Code 2 ) Thread d 2 l 1 l 2 L G ) Cross reference to ordering code digit 1, process connection, see page 2 Code 2 ) Thread d 2 l 1 l 2 J G Code 2 ) Nominal size d 2 l 1 M DN N DN 33.7/DN P DN 40/DN Q DN Mounting example Seal Clamp Seal Seal Welding sleeve Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 7

8 Connecting diagram Electrical connection For Voltage signal Output 0 max. 10 V For ma current loop version a a b I A UA RL U B U B c b I A R L d d Pin assignment Contact DIN plug Bendix 6 poles plug Cable 3 conductors DIN Binder plug ma 0...5/10 V DC ma 0...5/10 V DC ma 0...5/10 V DC ma 0...5/10 V DC a 1 1 B B Blue Blue 3 3 b 2 2 E E Brown Brown 1 1 c D - Black - 4 d GND GND Case Case Case Case View soldering side, cable socket blue brown black Pin assignment Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing ma 0...5/10 V DC ma 0...5/10 V DC ma 0...5/10 V DC ma 0...5/10 V DC a 1 1 Red Red b 2 2 Black Black c Green d Case Case Case Case 4 4 View soldering side, cable socket red black green Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 8

9 Options and accessories Alternate pressure ranges Code Range Code Range Code Range Code Range mbar mbar bar in H 2 O B B B B P B A A P P L L L L L L E ) E ) F ) E ) F ) F ) F ) F ) 17G G G G G G Code Range Code Range Code Range Code Range mm H 2 O m H 2 O m H 2 O m H 2 O P A A P P A L A L L L L A L L A L L L B A B B H ) H ) H ) H ) C ) C ) D ) E ) E ) E ) F ) F ) F ) F ) F ) Code Range Code Range Code Range Code Range MPa KPa KPa KPa A E E L L A L L A L L A B B A B P B A H H H H C C C D G G ) Valid only for ordering code digit 6, negative gauge pressure (code 5) Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 9

10 Options Adjusted to specific customer pressure range. The desired range must be given in plain text. Example: /SETR 500 mbar 2500 mbar Adjusted for specific medium temperature Example: /9007/0100 the ED 701 is adjusted for 100 C medium temperature. /SETR /9007/TTTT Accessories Welding sleeves Code 2 ) D a H Material J G Stainless steel D D a Code 2 ) D a H Material K G Stainless steel D H Adapter for high temperature (cooling device) EN DIN 3852 d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material C G 1 2 Stainless steel D C G 1 2 Stainless steel D C G 1 2 Stainless steel D EN EN d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material C G 1 2 Stainless steel D C G 1 2 Stainless steel D C G 1 2 Stainless steel D EN d G 1 2 l T NPT Code 2 ) T med max. l T d Connection Material C NPT Stainless steel D C NPT Stainless steel D C NPT Stainless steel D ) Cross reference to ordering code digit 1, process connection, see page 2 Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 10

11 Electrical accessories Cable socket connector DIN E Cable socket connector Binder E Cable socket connector Bendix E M12x Cable socket connector M12 E SW Cable socket connector M12 E M12 Extension cable E x LLL Type Shielded PVC cable 0 Shielded PUR cable 1 Standard PVC cable 2 Standard PUR cable 3 Length 2 meter cable meter cable meter cable meter cable Data Sheet A11 D6.180 Design and specifications subject to change without notice Page 11

12 E/ This data sheet may only be reproduced in full. Data Sheet A 11 D6.180 Design and specifications subject to change without notice Page 12

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

Industrial Pressure Transmitter

Industrial Pressure Transmitter ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

PRODUCT CATALOGUE PREssURE switch

PRODUCT CATALOGUE PREssURE switch PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to

More information

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006% ATEX documenting multifunction calibrator with high accuracy 0.006% is the top instrument of our range of ATEX documenting multifunction calibrators. Description is the top instrument of our range of ATEX

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

SmartLine Radar Level Meter RM70

SmartLine Radar Level Meter RM70 Page 1 of 5 SmartLine Radar Level Meter Model Selection Guide Reliable measurement in difficult process conditions +/- 3 mm / +/-0.12" standard accuracy Operates up to a flange temperature of 200 0 C /

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

SANMUR CONTROLS PVT. LTD.

SANMUR CONTROLS PVT. LTD. Decide with confidence NMUR CONTROLS NMUR CONTROLS PVT. LTD. An ISO 900:008 Certified Company The name NMUR has been synonymous with reliability and quality in terms of products, services and systems integration.

More information

Differential Pressure Switch

Differential Pressure Switch Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 80P. Field pressure calibrator with high accuracy 0.01% Field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. Description CALYS 80P is a field pressure calibrator within CALYS

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY

More information

all stainless steel transducer multimedia compatibility

all stainless steel transducer multimedia compatibility all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low

More information

Mineral-insulated thermocouples to DIN and EN

Mineral-insulated thermocouples to DIN and EN Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6 Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230 KTY 16-6 KTY 10-x KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 Features Temperature dependent resistor with positive temperature coefficient

More information

RoHS. Versatile. X g. X 2 e

RoHS. Versatile. X g. X 2 e s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k

More information

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET FKC...5 The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and

More information

Pressure. 1 Fitting PA R - N R2

Pressure. 1 Fitting PA R - N R2 INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides

More information

Fitting PS P - B - R2

Fitting PS P - B - R2 INTERNAL STRUCTURE PS86 (G 3/8) 2 3 FEATURES Solidstate pressure switch with no mechanical moving parts Isolated output via a photo-coupler Switching pressure adjustable and hysteresis band adjustable

More information

Type UB1 Load Cell. Option Stainless steel cable gland

Type UB1 Load Cell. Option Stainless steel cable gland Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER The FCX AIII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31. FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic TABLE OF CONTENT ATEX Certificate Explosionproof sensors from Pulsotronic code How to read sensor designations Circuit diagrams Connection according to EN 606 Sensors Cylinder M8 Cylinder M Cylinder M8

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Operating instructions Pressure sensor PN / / 2007

Operating instructions Pressure sensor PN / / 2007 Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Differential ph Probe Type 18

Differential ph Probe Type 18 Differential ph Probe Type 18 Contents 1 Introduction 1.1 Glass testing 2 Measuring principle 2.1 Model applications 3 Technical data 4 Handling information for the glasslined ph probe 5 Storage and installation

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

Connector~Tech Providing Harsh Environment Connector

Connector~Tech   Providing Harsh Environment Connector Connector~Tech www.connectortech.com.au Providing Harsh Environment Connector SOLUTIONS Tajimi TC18 series connectors are water-pro up to 30 meters in depth. Economical and highly reliable construction

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Bimetal Industrial Thermometers

Bimetal Industrial Thermometers ISO 9001:2008 CERTIFIED Bimetal Industrial Thermometers ISO 9001:2008 CERTIFIED Bimetal Industrial Thermometers 1000 Order Number Description Example: RG1350-R1712 trans lates to: R = Rear Mounting 13

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal

More information

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT

More information

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes with thin-film sensor element Probes Probe guides Measuring tubes Examples of Application Flow measurements also in hazardous locations Ex zone 0 or zone 1 in clean rooms in air conditioning and ventilating

More information

BTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters

BTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters FETURES to, to differential pressure...6 or... m Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDI CMPTIBILITY Pressure inlet: Non-corrosive,

More information

One-hand ph/temperature measuring instrument

One-hand ph/temperature measuring instrument One-hand ph/temperature measuring instrument testo 205 ph tip embedded in breakage-proof plastic ph Combined penetration tip with temperature probe Maintenance-free gel electrolyte C Measurement tip exchangeable

More information

Full Metal Variable Area Flow Meter and Counter

Full Metal Variable Area Flow Meter and Counter Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0

More information

Thermal Mass Flow Meter for Gases

Thermal Mass Flow Meter for Gases Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

PG-200/PG-208 PRESSURE GAUGES P G G P P

PG-200/PG-208 PRESSURE GAUGES P G G P P Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment

More information

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions: Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

VA Master FAM540 Metal Cone Variable Area Flowmeter

VA Master FAM540 Metal Cone Variable Area Flowmeter Contents Data Sheet Rev. B VA Master FAM50 Metal Cone Variable Area Flowmeter For metering liquids, gases and steam Graphic, 2-line display Magnet stick operation Configuration also possible with closed

More information

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016 APPLICATIONS Moisture monitoring of air or gas (SF6) Suitable for indoor or outdoor Industrial, medical or aerospace fields HIGHLIGHTS High voltage circuit breakers commonly used for distribution and transmission

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information