I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
|
|
- Osborn Bates
- 5 years ago
- Views:
Transcription
1 I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX Permissible ambient temperature C to + C / C to + C ( x W) C to + C ( x W / + /, excl. CG-S-Version) Rated voltage AC V - V AC Rated voltage AC (CG-S) V - V AC Rated voltage DC V - V DC Rated voltage DC (CG-S) V - V DC Frequency - Hz Power factor cos ϕ >=. Circuit EVG resp. EVG/CG-S Connecting terminals L, N, PE max. x. mm, clamp terminals; optional screw-type terminals max. x mm Insulation class I Lamp cap G accd. to IE Degree of protection accd. EN IP Cable glands/gland plates/enclosure drilling Ex e cable glands M x. (plastic) for cables from Ø - mm Option: M x. metal thread Enclosure material Glass-fibre reinforced polyester Protective cover/protective bowl Polycarbonate nllk / Rated current. A /. A (CG-S variant) Lamp/illuminant x T / W Rated luminous flux ) lm Light efficiency in operation % Dimensions (L x W x H) x x mm Weight approx.. kg / approx.. kg (CG-S variant) nllk nllk / Rated current. A. A /. A (CG-S variant) Lamp/illuminant x T / W x T / W Rated luminous flux ) lm lm Light efficiency in operation % % Dimensions (L x W x H) x x mm x x mm Weight approx.. kg approx.. kg /approx.. kg (CG-S variant) nllk nllk / Rated current. A /. A (CG-S variant) Lamp/illuminant x T / W Rated luminous flux ) lm lm Light efficiency in operation % % Dimensions (L x W x H) x x mm x x mm Weight approx.. kg approx.. kg / approx.. kg (CG-S variant) ) depends on used lamps COOPER CROUSE-HINDS GMBH.
2 I nllm / I nllm / I nllm Technical data Cooper Crouse-Hinds - all rights reserved nllm / nllm / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity statement PTB ATEX Permissible ambient temperature - C to + C Rated voltage V - V AC Rated voltage V - V DC Frequency - Hz Power factor cos ϕ. Circuit EVG Connecting terminals L, N, PE screw-type terminals max. x mm Insulation class I Lamp cap G accd. to IE Degree of protection accd. EN IP Cable glands x Ex e cable glands M x. (plastic) for cables from Ø - mm Enclosure material Glass-fibre reinforced polyester Protective cover/protective bowl Polycarbonate nllm / nllm / Rated current. A. A Lamp/illuminant x T / W x T / W Rated luminous flux ) lm lm Light efficiency in operation % % Dimensions (L x W x H) x x mm x x mm Pole socket Ø mm x mm Ø mm x mm Weight approx.. kg approx.. kg ) depends on used lamps. COOPER CROUSE-HINDS GMBH
3 I nllk / I nllm / I nllm / I x W x W x W x W x W Ordering details Type Connecting Through-wiring Cable glands ) Plugs Order No. terminals single-ended double-ended Cooper Crouse-Hinds - all rights reserved Type nllk / ( x W) /- x x x M x. x threaded /- x x x M x. x threaded /- M ) ) x x x M x. x threaded Type nllk / CG-S ) ( x W) /- ) x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllm / ( x W) /- x x M x. Type nllk ( x W) /- x x x M x. x threaded /- x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllk / ( x W) /- x x x M x. x threaded /- x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllk / CG-S ) ( x W) /- ) x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllm / ( x W) /- x x M x. Type nllk ( x W) /- x x x M x. x threaded /- x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllk / ( x W) /- x x x M x. x threaded /- x x x M x. x threaded /-M ) ) x x x M x. x threaded Type nllk / CG-S ) ( x W) /- ) x x x M x. x threaded /-M ) ) x x x M x. x threaded ) M: with metal thread, without cable gland ) CG-S: design single monitored emergency light fitting for use in CEAG emergency light supply unit ) With dustcover if entry/thread is not closed ) With screw-type terminals max. x mm Version with integrated isolating switch on request Scope of delivery without lamp and fixing accessoires COOPER CROUSE-HINDS GMBH.
4 I nllk / I nllm / I nllm / I x W x W x W x W x W Accessories Cooper Crouse-Hinds - all rights reserved Lamp for luminaire nllk/nllm Type of lamp Power Luminous flux Order No. socket/ Light colour Diameter Bi-pin socket G W lm universal white T/Ø mm (T) lm universal white G--IEC-- Bi-pin socket G W lm universal white T/Ø mm (T) lm universal white G--IEC-- Bi-pin socket G W lm universal white T/Ø mm (T) lm universal white G--IEC-- Aura-Ultimate W lm universal white T/Ø mm (T) Longlife W lm universal white Socket G W lm universal white on request Series nllk... and nllm... Type Order No. Hexagon screw SW Series nllm / and nllm / Type Order No. Single sided through wiring / with entries M, incl. terminals and mounting material Fixing materials nllk Type/code Corrosion Qty. Order No. protection per light fitting Eye bolt A galvanized Hexagon screw S stainless steel Ceiling mounting bracket D stainless steel incl. screws and washer Fixing materials nllk... and nllm... Type/code Corrosion for pipes Outer Ø Qty. Order No. protection DIN D (mm) per light fitting Pipe clamp R hot galvanized / - R CrNi / - R hot galvanized / - R CrNi / - R hot galvanized - R CrNi - Wall bracket W hot galvanized. Luminaire wall suspension hot galvanized incl. screws and washer. COOPER CROUSE-HINDS GMBH
5 I nllk / I nllm / I nllm / I x W x W x W x W x W Dimension drawing Accessories. M x. W = W = W = W = W/ W = Hexagon SW M, deep Cooper Crouse-Hinds - all rights reserved nllk/m / / nllk/m / C W = W = W = nllk/m / nllk C nllk / C Ø. x M Eye bolt Wall bracket Ø M D M Ø Ø Ceiling mounting bracket D Pipe clamp Luminaire wall suspension COOPER CROUSE-HINDS GMBH. M Dimensions in mm
Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More information2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm
1 E X - F L U O R E S C E N T L I G H T F I T T I N G S 2 3 6 EX-LIGHT FITTING ellk 2... MAIN FEATURES EX-LIGHT FITTING ellk 2... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 2... EX-EMERGENCY LIGHT
More informationEX-FLUORESCENT LIGHT FITTINGS
EX-FLUORESCENT LIGHT FITTINGS Cooper Crouse-Hinds 00 - all rights reserved EX-LIGHT FITTING ellk... MAIN FEATURES.0 EX-LIGHT FITTING ellk... EX-POLE MOUNTED LIGHT FITTING ellm....0. EX-EMERGENCY LIGHT
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationE X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S
1 E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 2 4 5 6 8 EX- CEILING LIGHT FITTINGS EX- PENDANT LIGHT FITTINGS 4.41 4. EX- FLOODLIGHTS EX- VESSEL LIGHT FITTING
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationCEAG Products Main Catalogue Part 1 Chapter 2. Ex-Light fittings. EATON 1.2.1
CEAG Products Main Catalogue Part 1 Chapter Ex-Light fittings www.crouse-hinds.de EATON 1..1 1.. EATON www.crouse-hinds.de Ex-Light fittings Table of contents.1 Information on Ex-linear light fittings
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationCEAG Products Main Catalogue Part 1 Chapter 4. Ex-Ceiling, pendant light fittings and floodlights. EATON 1.4.1
CEAG Products Main Catalogue Part 1 Chapter Ex-Ceiling, pendant light fittings and floodlights www.crouse-hinds.de EATON 1..1 2 1..2 EATON www.crouse-hinds.de Ex-Ceiling, pendant light fittings and floodlights
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationGB-distribution boxes and enclosures
GBdistribution boxes and enclosures, polyester, to European Standards (ATEX) Features þ ATEXcertified þ BASEEFAcertified þ Large range of s including BARTEC, Weidmüller, Phoenix þ Different enclosure s
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationInstallation Equipment
Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester
More information4.35. Accessories for Ex-Ceiling light fitting AB 80. Guard GAB 80 NOR Accessories for Ex-Pendant light fitting AB 50
EV... 0-0 ZM EVI 00 UD AB 0 IU AB 0. Accessories for Ex-Ceiling light fitting AB 0 Guard GAB 0 NOR 000 00 0 Accessories for Ex-Pendant light fitting AB 0 Ceiling bracket with screws / AS.EV/AB NOR 000
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationPiù alto 3d flat»cc«datasheet
Datasheet LED wall / ceiling spotlight with single-sided light output. Optionally available with optics (Più) or flat with internal (Più R). Version with flat base for fitting on hollow ceiling or flush-mounted
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationEXPLOSION PROOF ATEX LUMINAIRE
info@nextgenerationled.be www.nextgenerationled.be Tel + 32 53 71 09 42 EXPLOSION PROOF ATEX LUMINAIRE Properties n Lifespan L80 %: > 50.000 hours n Atex directive 94/9 EC n Zone 2 and 22 n IP klasse :
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationZ7A. Load cells. Special features. Data sheet. Wiring code
Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationPHOS 15 LED PROJECTOR
PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationMotor Protection Circuit Breaker Series 8146/5-V27
> For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationLevel Sensor PanCake PR 6251 and Mounting Kit PR 6051
Level Sensor PanCake PR 6251 and Mounting Kit PR 6051 The space-saving solution for simple applications The sensors of the PR 6251 series have been specially designed for simple weighing of silos and horizontal
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationChapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar
Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationMKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits
MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationThe FLUX F 430 with mechanical seal
The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationTechnical specification FLUXUS F502TE
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationFlexSQUARE Square shaped beacons
FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact 853 LED beacon is particularly versatile. With an
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationDRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories
Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from
More informationvariable flow dampers
Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationDRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories
Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from
More informationEx floating switches and Ex immersion probes
Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466
More informationLED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315
D Product description Ideal for ceiling-mounted and wallmounted luminaires Based on annular and compact fluorescent lamps Efficiency of the module up to 127 lm/w SO version is compatible with SWITCH Sensor
More informationct m ive p 5/EC Thermal cut-outs
RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationLuxSpace recessed high efficiency, visual comfort and a stylish design
Lighting LuxSpace recessed high efficiency, visual comfort and a stylish design LuxSpace Mini, recessed Customers are looking to optimize all their resources, and that means not just their running costs
More informationPHASED OUT. LED light engines LED linear / area. Module QLE G1 471x462mm 5000lm SNC Modules QLE ESSENCE
Product description Luminous flux: 5, lm per module Square module one module per luminaire nonselv (HV) and SELV (LV) variants High colour rendering index CRI 8 Small colour tolerance (MacAdam 4) Efficacy
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationM2 V0 IN ON A POLE. Material Aluminium Polycarbonate. Finish White Transparent TECHNICAL CHARACTERISTICS
71-5156-14-M2V0 ON A POLE Finish White Transparent IP20 Material Aluminium Polycarbonate 40º 50 TECHNICAL CHARACTERISTICS Light source Light source: LED Output (W): max. 13W Color temperature: Warm White
More informationindustry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013
industry hall Customer : Processed by : Siteco Light Consulting Project description: spatial geometry (L*W*H): 54,00m*21,00m*9m reflection values (C*W*F): 70*50*20 maintenance factor: 0,67 user surface
More informationSection Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series
Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationSOCCER FIELDS LEVELS FOR UEFA COMPETITIONS ELITE LEVEL A LEVELS : A-B-C-D
SOCCER FIELDS LEVELS FOR UEFA COMPETITIONS ELITE LEVEL A LEVELS : A-B-C-D SPORT-LED SPECIAL LIGHTING EQUIPMENT Soccer Field for UEFA competitions Example Soccer Fields UNIFORMITY > 0.90 from > 800 lux
More informationIM 1001 IM 3001 (1) IM 2001 (1) IM 3601 (1) IM 2101 (1) at 50/60 Hz (IM B3) (IM B5) (IM B35) (IM B14) (IM B34) Max. Max.
2016/09/05 version 230 V Δ / 380 V Υ / 400 V Υ / 415 V Υ 50 Hz - 460 V Υ 60 Hz L 0.75 4910125 10 4910126 4 4910127 1 4910129 1 4910130 1 LG 1.1 4910138 10 4910139 4 4910140 1 4910142 1 4910143 1 SL 1.5
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More information