GEOTECHNICAL INVESTIGATION FOR MASTER DEVELOPMENT PLAN EFFORT

Size: px
Start display at page:

Download "GEOTECHNICAL INVESTIGATION FOR MASTER DEVELOPMENT PLAN EFFORT"

Transcription

1 GEOTECHNIEK MILIEU ONDERZOEK FUGRO CONSULTANTS, INC. GEOTECHNICAL INVESTIGATION FOR MASTER DEVELOPMENT PLAN EFFORT CSJ: NTE 4 HIGHWAY: IH 820 FROM RANDOL MILL ROAD TO WEST PIPELINE ROAD AND SH 121 FROM MIDWAY ROAD TO IH 820 FUGRO PROJECT NO AECOM CONTRACT NO REPORT TO: AECOM TRANSPORTATION JULY 2010

2 FUGRO CONSULTANTS, INC. Project No July 6, 2010 AECOM Transportation 1420 W. Mockingbird Lane, Suite 300 Dallas, Texas Virgo Lane Dallas, TX Phone: Fax: Attention: Mr. Jiri Filipovic, P.E. Project Director AECOM Contract No Master Development Plan Effort CSJ: NTE 4 - CDA Highway: IH 820 from Randol Mill Road to West Pipeline Road and SH 121 from Midway Road to IH 820 County : Tarrant Dear Mr. Filipovic: We are pleased to transmit the geotechnical Master Development Plan (MDP) report for NTE 4. This report includes a site vicinity map, plans of borings, gint boring logs, Wincore boring logs, generalized subsurface profiles, and laboratory test results. These services were performed in accordance with the scope described in Appendix A Geotechnical Scope of Work of the referenced contract. We appreciate the opportunity to work on this project. Please feel free to contact us if you have any questions upon reviewing this document. Sincerely, FUGRO CONSULTANTS, INC. TBPE Firm Registration No. F-299 Andrew D. Johnson, P.E. Project Engineer Saad M. Hineidi, P.E. Senior Vice President Chula B. Ellepola, P.E. Senior Geotechnical Engineer ADJ/SMH/CBE/kp Attachments: Site Vicinity Map and Plans of Borings (Appendix A) gint Boring Logs and Keys to Terms and Symbols for Soil and Rock (Appendix B) Key to Terms and Symbols used on TxDOT Logs and Wincore Boring Logs (Appendix C) Generalized Subsurface Profiles (Appendix D) Summary of Laboratory Test Results (Appendix E) Particle Size Distribution Reports (Appendix F) Unconfined Compression Test Results (Appendix G) Unconsolidated Undrained Compression Test Results (Appendix H) Sulfate and Lime Series Test Results (Appendix I) A member of the Fugro group of companies with offices throughout the world

3 Project No APPENDICES Appendix A Appendix B Site Vicinity Map and Plans of Borings Boring Logs and Keys to Terms and Symbols for Soil and Rock Appendix C Appendix D A Key to Terms and Symbols Used on TxDOT Boring and Wincore Boring Logs Generalized Subsurface Profiles Logs Appendix E Summary of Laboratory Test Results Appendix F Particle Size Distribution Reports Appendix G Unconfined Compression Test Results Appendix H Unconsolidated Undrained Compression Test Results Appendix I Sulfate and Lime Series Test Results

4 Project No APPENDIX - A SITE VICINITY MAP AND PLANS OF BORINGS

5 Mid Cities Glenview Pipeline Trinity Midway John T White REV DATE BY DESCRIPTION UV 26 Harwood UV 121 Bedford Euless M esquite B ranch Precinct Line Hurst Calloway Branch Randol Mill Arlington Walker Branch West Fork Trinity River Cooks Cottonwood C reek UV 10 John T White 30 Meadowbrook Sandy UV 121 Fort Worth Craig Airport TARRANT COUNTY FM 1938 UV Bridgewood Handley Handley Ederville North Richland Hills UV 183 Richland Hills Mid Cities Rufe Snow Big Fossil Creek UV Minnis Bridge Watauga Watauga Broadway Haltom City Legend Seg4 Alignment Scale: 1 inch = 3,000 feet Feet 0 1,500 3,000 6,000 Coordinate System: State Plane Texas North Central FIPS 4202 Ft Datum: D North American 1983 VICINITY MAP North Tarrant Expressway Segment 4 Source: Orthophotography: i-cubed via ArcGIS Online, 2007 Drawn By: DF Tarrant County, Texas Date: June 17, 2010 Project No.: PLATE A-1

6 Latham Dr Trinity Sand St REV DATE BY DESCRIPTION UV 10 A A B4-16 UV 10 B4-17 UV 183 Hurst UV 121 Wesley Way Central Park Dr A B4-15 A A B4-14 B4-13 Airport A B4-12 B4-11 A A B4-10 Gravel Dr A E Loop 820 N A 820 A A A A A A A B4-9 B4-8 B4-7 B4-6 B4-5 B4-4 B4-3 B4-2B4-1 Pebble Dr Flagstone St Tennis Ct Mosier View Ct Jack Newell Blvd S Randol Mill Stonegate Dr N Stone Forest Dr Manhattan Blvd Loop 820 Canyon Oak Dr Vistaview Dr Sunflower Cir N Sandybrook Dr E Loop 820 Sandstone Dr Bobwhite Dr Mandy Ln Misty Glen Ct Woodchucker Dr Bridgewood Tower St Sunset Oak Dr UV 183 Whitehall St Airport Fwy Elm Park Dogwood Park A B4-22 Fir Park Richland Hills A B4-23 Burns St Belton St Handley Ederville Midway Rd Robotics Pl Stoneway Dr S TARRANT COUNTY Reeves Pl Stoneway Dr N Fort Worth Riverview Cir Canyon Creek Trl Cholla Dr Highwoods Trl Boca Raton Blvd Cedar Park Blvd Birch Park Dr A B4-24 Atco Dr Terrace Oaks Ln Silverleaf Ct Paloverde Ct Paloverde Ln Indigo Ct Lantana Ln Maple Park Dr Riverbend West Dr Oakwood Trl Scruggs Park Dr Mimosa Park Dr Park Place Dr Ash Park Dr Scruggs Park Dr Pine Park Dr Airport Fwy Willow Park St Spruce Park Dr A B4-25 Mimosa Park Dr UV 121 Austin Rd Enterprise Ave Forest Ln Forest River Dr Oak Hollow Ln Havenwood Ln N Putter Dr SITE AND BORING PLAN North Tarrant Expressway Legend A Seg 4 Boring Locations Scale: 1 inch = 1,000 feet Feet ,000 2,000 Coordinate System: State Plane Texas North Central FIPS 4202 Ft Datum: D North American 1983 Segment 4 Source: Orthophotography: i-cubed via ArcGIS Online, 2007 Drawn By: SE Tarrant County, Texas Date: January 22, 2010 Project No.: PLATE B-1

7 Pipeline Glenview Oxley Dr Richland Rd Dover Ln Sand St N Hills Blvd Encino Dr Calcutta St Bridges Ave Hardisty St Willow St Kevin Dr Powers St Crestview Dr Shadow Grass Ave Decoy Ln REV DATE BY DESCRIPTION Zelda Dr Pacific St Castle Dr Royal Ln Park Place Blvd Barrington Crossing Apartment Holly Hill Dr Kathryn St W Redbud Dr Greenwood Dr Henson Dr Billy Creek Dr Melbourne Rd Harris Ave Walker Dr Fanning Dr Bradford Dr Bradford Ct Gifford-Hill Rd UV 10 Trinity Vista Trl Riversprings Dr Bowspirit Ln Salado Trl Goldeneye Ln Trinity Ct NE Mall Blvd Belmont St Hurst P C Wynne Ln Oakwood Dr Glenn Dr Conn Dr UV 121 Keeter Dr Frawley Dr Airport Fwy NE Loop 820 Cagle Dr A B4-21 TARRANT COUNTY Jordan Dr Airline Dr Beth Ct Booth Calloway Rd Evergreen Rd Kathryn Ct A A B4-20 Granada Dr Labadie Dr Scranton Dr B4-19 Jonette Dr Chaffin Dr Landy Ln Cooper Dr A B4-18 UV 121 Richland Hills Labadie Dr Evelyn Dr Unnamed Street Jonette Dr Cardinal Rd Booth Rd A A B4-16 UV 10 B4-17 Central Park Dr S Booth Calloway Rd A B4-15 A A B4-14 B4-13 Airport UV 183 UV UV Whitehall St Wesley Way Tower St Airport Fwy Dogwood Park A B4-12 Trinity B4-11 A A B4-10 Gravel Dr Fort Worth A E Loop 820 N A 820 A A B4-9 B4-8 B4-7 B4-6 Pebble Dr Flagstone St Jack Newell Blvd N Tennis Ct Mosier View Ct Jack Newell Blvd S A Legend A Seg 4 Boring Locations Scale: 1 inch = 1,000 feet Feet ,000 2,000 Coordinate System: State Plane Texas North Central FIPS 4202 Ft Datum: D North American 1983 SITE AND BORING PLAN North Tarrant Expressway Segment 4 Source: Orthophotography: i-cubed via ArcGIS Online, 2007 Drawn By: SE Tarrant County, Texas Date: January 22, 2010 Project No.: PLATE B-2

8 Project No APPENDIX - B BORING LOGS KEYS TO TERMS AND SYMBOLS FOR SOIL AND ROCK

9 LOG OF BORING NO. B4-1 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 1.5 P = 2.5 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SAND, reddish tan and brown, moist, loose to dense, with trace gravel and limestone fragments LAYER ELEV./ DEPTH WATER CONTENT, % 15 LIQUID 36 PLASTIC 12 PLASTICITY INDEX (PI), % 24 PASSING NO. 200 SIEVE, % 44 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 2.5 P = P = P = /8.5" N = 50/5" LIMESTONE, moderately weathered, tan, soft to hard, moist LIMESTONE, light gray, hard, dry /2.25" 10'-15' 97/ 65 SHALE, gray to brown, soft to hard, moist /2.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-20' 75/ /4" 20'-25' 87/ 87 Fugro Consultants, Inc. COMPLETION DEPTH: 45.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY 20 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE a

10 LOG OF BORING NO. B4-1 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2.5" 25'-30' STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray to brown, soft to hard, moist (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 80/ /2.75" 30'-35' 95/ /2" 35'-40' 88/ /2.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 97/ /0.5" Fugro Consultants, Inc. LIMESTONE, light gray, very hard, dry COMPLETION DEPTH: 45.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

11 LOG OF BORING NO. B4-2 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 4.5+ P = 3.75 STRATUM DESCRIPTION SURF. ELEVATION: FILL, Hot-Mix Asphaltic Concrete (HMAC) 10.0" FILL, SAND, reddish brown and brown, moist, loose LAYER ELEV./ DEPTH WATER CONTENT, % 20 LIQUID 31 PLASTIC 14 PLASTICITY INDEX (PI), % 17 PASSING NO. 200 SIEVE, % 39 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 5 P = 4.5 P = 4.5+ P = /9" SANDY LEAN CLAY (CL), tan, moist, hard, calcareous LIMESTONE, moderately weathered, tan, soft, moist, fractured, with intermittent clay seams N = 50/3" LIMESTONE, light gray, hard to very hard, dry, fractured, with intermittent shale lenses /2.75" 10'-15' / /2.25" SHALE, gray, soft, moist, calcareous, with intermittent limestone seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-20' 97/ /0.75" 20'-25' 98/ 55 Fugro Consultants, Inc. LIMESTONE, light gray, hard to very hard, dry, fractured, with interbedded shale seams COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE a

12 LOG OF BORING NO. B4-2 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1" 25'-30' 100/ 77 STRATUM DESCRIPTION SURF. ELEVATION: LIMESTONE, light gray, hard to very hard, dry, fractured, with interbedded shale seams (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /1" 30'-35' 98/ 88 SHALE, gray to brown, soft to hard, moist, fissile /1.75" 35'-40' 97/ /1.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 85/ /2" 45'-50' 97/ 97 Fugro Consultants, Inc. COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE b

13 LOG OF BORING NO. B4-2 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH 50.0 WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

14 LOG OF BORING NO. B4-3 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 3.5 P = 3.0 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SAND, brown, compact, moist, with trace calcareous nodules FAT CLAY (CH), brown, very stiff, moist, with fine-grained sand LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 27 PLASTIC 13 PLASTICITY INDEX (PI), % 14 PASSING NO. 200 SIEVE, % 37 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 5 P = /9.75" LEAN CLAY WITH SAND (CL), tan, stiff to hard, dry, calcareous N = N = /12" N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 31 60/12" Fugro Consultants, Inc. COMPLETION DEPTH: 20.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE

15 LOG OF BORING NO. B4-4 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.0 P = 1.75 STRATUM DESCRIPTION SURF. ELEVATION: FILL, Hot-Mix Asphaltic Concrete (HMAC) 12.0" FAT CLAY (CH), dark brown to brown, moist, soft, with trace calcareous nodules LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 3.0 P = /12" P = P = 4.5 P = P = /12" FAT CLAY WITH SAND (CH), brown, moist, stiff, with trace to few calcareous nodules SANDY LEAN CLAY (CL), light brown, moist, stiff N = 35 POORLY GRADED SAND WITH GRAVEL (SP), tan, dry to saturated, slightly compact FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /8.25" N = 50/4" 100/1.5" Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH SAND (GP), tan, wet, dense LIMESTONE, moderately weathered, tan, hard, moist, fractured, with interbedded clay seams SHALE, gray, hard, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, very hard, dry, with intermittent shale lenses COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 15.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

16 LOG OF BORING NO. B4-4 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.5" 25'-30' 100/ 87 SURF. ELEVATION: STRATUM DESCRIPTION SHALE, gray, hard, moist, calcareous, with intermittent limestone lenses LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /3.75" 30'-35' 93/ /1" 35'-40' 98/ 75 LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses SHALE, gray, very hard, moist, calcareous, with intermittent limestone lenses FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /0.75" 40'-45' 98/ /0.75" 45'-50' 98/ 92 Fugro Consultants, Inc. LIMESTONE, light gray, very hard, dry, with intermittent shale lenses SHALE, gray, soft to very hard, moist, calcareous, with intermittent limestone lenses COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 15.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE b

17 LOG OF BORING NO. B4-4 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.75" 50'-55' 100/ 95 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, soft to very hard, moist, calcareous, with intermittent limestone lenses (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /1.5" 55'-60' 98/ /1.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 15.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

18 LOG OF BORING NO. B4-5 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 1.5 P = 3.0 P = 3.0 SURF. ELEVATION: FILL, CLAY, brown, moist, soft to very stiff, with trace gravel FILL, SAND, tan, wet, loose STRATUM DESCRIPTION LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 37 PLASTIC 13 PLASTICITY INDEX (PI), % 24 PASSING NO. 200 SIEVE, % 36 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = /12" P = 1.25 FILL, CLAY, brown, moist, soft to stiff P = 3.0 P = 1.0 P = 1.0 FILL, SAND, tan to reddish tan, moist, loose, with trace gravel /12" FILL, SAND, reddish tan, moist to wet, slightly compact, with interbedded clay seams and cemented sand fragments N = 14 15/12" FILL, CLAY, brown and gray, moist, soft to stiff, with few calcareous nodules FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 P = 2.0 P = /12" N = 14 Fugro Consultants, Inc. COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 45.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE a

19 LOG OF BORING NO. B4-5 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 17/12" STRATUM DESCRIPTION SURF. ELEVATION: FILL, CLAY, brown and gray, moist, soft to stiff, with few calcareous nodules (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = /12" P = P = /12" P = P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 P = 2.0 P = /12" P = 1.0 P = 1.0 Fugro Consultants, Inc. LEAN CLAY WITH SAND (CL), brown and gray, moist to saturated, soft, with intermittent sand lenses COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 45.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE b

20 LOG OF BORING NO. B4-5 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 14/12" STRATUM DESCRIPTION SURF. ELEVATION: LEAN CLAY WITH SAND (CL), brown and gray, moist to saturated, soft, with intermittent sand lenses (continued) POORLY GRADED SAND WITH GRAVEL (SP), tan, wet, loose, to slightly compact LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 55 N = 30 71/12" POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, wet, compact to dense '-60' 92/ 80 LEAN CLAY WITH SAND (CL), gray and brown, moist, soft, trace calcareous nodules N = 11 13/12" P = 0.5 P = 0.5 LEAN CLAY WITH SAND (CL), brown and gray, wet, very soft to soft /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 P = 0.5 P = /12" P = 0.5 P = 0.5 Fugro Consultants, Inc. SANDY LEAN CLAY (CL), gray and brown, wet, soft COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 45.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

21 LOG OF BORING NO. B4-5 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 10/12" STRATUM DESCRIPTION SURF. ELEVATION: SANDY LEAN CLAY (CL), gray and brown, wet, soft (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 80 N = 67 92/11" POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, moist, compact to dense, with few clay seams N = /6" SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ N = /0.75" 90'-95' 98/ /4.5" 95'-100' 92/ 85 Fugro Consultants, Inc. LIMESTONE, light gray, very hard, dry SHALE, gray and brown, soft, moist, calcareous, with intermittent limestone seams COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 45.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE d

22 LOG OF BORING NO. B4-5 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ Fugro Consultants, Inc. COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 45.0 UPON COMPLETION: 45.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE e

23 LOG OF BORING NO. B4-6 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 3.5 P = 3.5 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, reddish tan and brown, moist, soft, with trace gravel and intermittent sand seams LAYER ELEV./ DEPTH WATER CONTENT, % 15 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = 1.5 P = /12" P = 3.0 P = 3.0 FILL, CLAY, brown, moist, soft, with trace calcareous nodules P = P = /12" FILL, SAND, reddish tan, moist, loose to dense, with few cemented sand fragments P = 0.5 P = /7.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 25 24/12" N = 11 Fugro Consultants, Inc. FILL, CLAY, tan and brown, moist, stiff to very stiff, with few limestone fragments COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

24 LOG OF BORING NO. B4-6 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 21/12" STRATUM DESCRIPTION SURF. ELEVATION: FILL, CLAY, tan and brown, moist, stiff to very stiff, with few limestone fragments (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF LEAN CLAY (CL), dark brown and gray, moist, soft to stiff, with trace calcareous nodules N = /12" P = P = /12" P = P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 P = 3.25 P = /12" P = 4.0 P = 3.0 Fugro Consultants, Inc. COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

25 LOG OF BORING NO. B4-6 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 26/12" STRATUM DESCRIPTION SURF. ELEVATION: LEAN CLAY (CL), dark brown and gray, moist, soft to stiff, with trace calcareous nodules (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 1.75 P = 1.0 LEAN CLAY WITH SAND (CL), light brown and gray, moist to wet, soft, with trace calcareous nodules /12" P = 1.0 SANDY LEAN CLAY (CL), light brown, wet, soft, with trace calcareous nodules P = /12" CLAYEY SAND (SC), light brown, wet, slightly compact POORLY GRADED SAND (SP), tan, moist to wet, loose to compact, with intermittent clayey sand seams N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 N = 21 82/12" N = 42 Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, wet, compact to dense, with few clay seams COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 8 PLATE c

26 LOG OF BORING NO. B4-6 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 84/11.5" STRATUM DESCRIPTION SURF. ELEVATION: POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, wet, compact to dense, with few clay seams (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = /6" SHALE, gray and brown, soft to very hard, moist, calcareous, with intermittent limestone seams N = /3.5" 85'-90' 93/ /0.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-95' 100/ /0.75" 95'-100' 87/ 60 Fugro Consultants, Inc. COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE d

27 LOG OF BORING NO. B4-6 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.75" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ Fugro Consultants, Inc. COMPLETION DEPTH: DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: 24.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE e

28 LOG OF BORING NO. B4-7 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.0 STRATUM DESCRIPTION SURF. ELEVATION: FILL, CLAY, dark brown, moist, soft, with trace gravel LAYER ELEV./ DEPTH WATER CONTENT, % 22 LIQUID 47 PLASTIC 18 PLASTICITY INDEX (PI), % 29 PASSING NO. 200 SIEVE, % 71 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 2.5 P = 2.5 FAT CLAY (CH), brown, moist, soft to stiff, with trace calcareous nodules P = 2.0 P = /12" P = 3.5 P = P = P = /12" P = 3.5 P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 P = 3.5 P = /12" P = 1.5 P = 1.75 Fugro Consultants, Inc. LEAN CLAY WITH SAND (CL), light brown and gray, moist to saturated, soft, with trace calcareous nodules COMPLETION DEPTH: 85.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 23.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

29 LOG OF BORING NO. B4-7 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 17/12" STRATUM DESCRIPTION SURF. ELEVATION: LEAN CLAY WITH SAND (CL), light brown and gray, moist to saturated, soft, with trace calcareous nodules (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % 81 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = /12" P = 0.5 SANDY LEAN CLAY (CL), light brown and gray, moist to wet, very soft to soft P = /12" P = 0.5 SILTY CLAYEY SAND (SC-SM), light brown and gray, wet, very loose, with intermittent sand seams P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 N = 12 27/12" N = 81 Fugro Consultants, Inc. POORLY GRADED SAND (SP), tan, wet, loose to slightly compact POORLY GRADED GRAVEL WITH SAND (GP), tan, moist, compact to very dense, with few clay lenses COMPLETION DEPTH: 85.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 23.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

30 LOG OF BORING NO. B4-7 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/4" STRATUM DESCRIPTION SURF. ELEVATION: POORLY GRADED GRAVEL WITH SAND (GP), tan, moist, compact to very dense, with few clay lenses (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = /10.5" SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams N = /3.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /0.75" 65'-70' 90/ /0.75" 70'-75' 98/ 92 Fugro Consultants, Inc. LIMESTONE, light gray, very hard, dry, with interbedded shale lenses SHALE, brown and gray, soft to very hard, moist, slightly calcareous, fossiliferous COMPLETION DEPTH: 85.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 23.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE c

31 LOG OF BORING NO. B4-7 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1" 75'-80' 98/ 98 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, brown and gray, soft to very hard, moist, slightly calcareous, fossiliferous (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /1.75" 80'-85' 98/ /1.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 95 Fugro Consultants, Inc. COMPLETION DEPTH: 85.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 23.0 UPON COMPLETION: 20.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE d

32 LOG OF BORING NO. B4-8 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.0 STRATUM DESCRIPTION SURF. ELEVATION: CLAYEY SAND (SC), reddish brown, moist, loose LAYER ELEV./ DEPTH WATER CONTENT, % 11 LIQUID 40 PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 3.0 N = 13 SILTY SAND (SM), reddish tan, moist, loose N = 14 54/12" POORLY GRADED SAND WITH GRAVEL (SP), tan, slightly compact to compact, water bearing, fine to medium sand, with fine angular to round gravel N = 29 N = 22 30/12" POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, wet, slightly compact, fine to coarse subangular to round gravel, with medium to coarse sand N = 32 FAT CLAY (CH), light brown to gray, moist, stiff to very stiff, slickensided FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /8" 100/5.5" 20'-25' 90/ 58 Fugro Consultants, Inc. LIMESTONE, tan, hard, moist, weathered, fractured, with intermittent clay seams SHALE, gray, soft, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams COMPLETION DEPTH: 45.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 4.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

33 LOG OF BORING NO. B4-8 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.75" 25'-30' 97/ 83 SURF. ELEVATION: STRATUM DESCRIPTION SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF SHALE, gray, hard, moist, fissile /1.25" 30'-35' 80/ /2.25" 35'-40' 97/ 65 LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams /0.75" SHALE, gray, soft to hard, moist, with calcareous nodules and intermittent limestone seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 98/ /0.75" Fugro Consultants, Inc. LIMESTONE, light gray, very hard, dry, with interbedded cemented lenses SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams COMPLETION DEPTH: 45.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 4.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

34 LOG OF BORING NO. B4-9 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.0 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, dark brown, moist, soft, (Fill) LAYER ELEV./ DEPTH WATER CONTENT, % 18 LIQUID 39 PLASTIC 13 PLASTICITY INDEX (PI), % 26 PASSING NO. 200 SIEVE, % 49 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 2.5 P = 2.5 P = 2.0 FAT CLAY WITH SAND (CH), light brown, moist, soft, with trace calcareous nodules P = /12" P = 2.0 P = 2.5 N = 8 LEAN CLAY WITH SAND (CL), light brown, moist, soft POORLY GRADED SAND (SP), reddish tan, moist, loose /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ N = /2" 100/1.75" 20'-25' 93/ 72 Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH SAND (GP), tan, wet, compact LIMESTONE, tan, hard to very hard, dry, weathered, fractured LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

35 LOG OF BORING NO. B4-9 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.5" 25'-30' 98/ 98 SURF. ELEVATION: STRATUM DESCRIPTION SHALE, gray, soft, moist, fissile LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /7.5" 30'-35' 87/ /1" 35'-40' SHALE, gray, soft, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, hard to very hard, dry, with interbedded shale lenses / 48 SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, very hard, dry, with interbedded shale seams /0.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 93/ /0.75" 45'-50' 98/ 85 Fugro Consultants, Inc. SHALE, gray, very hard, moist, calcareous, with intermittent limestone seams SHALE, gray, hard to very hard, moist, fissile COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

36 LOG OF BORING NO. B4-9 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" 50'-55' 97/ 97 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, hard to very hard, moist, fissile (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /2.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: 8.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

37 LOG OF BORING NO. B4-10 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 0.5 P = 3.5 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, reddish brown, moist, soft, with fine-grained sand, iron stains, and fine rounded to subrounded gravel LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 36 PLASTIC 12 PLASTICITY INDEX (PI), % 24 PASSING NO. 200 SIEVE, % 57 UNIT DRY WEIGHT, PCF 95 UNCONFINED STRENGTH TSF 0.7 P = P = P = /12" 13 P = P = P = P = /12" 13 P = 3.5 FILL, CLAY, light gray, moist, soft, with fine grained sand P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 P = 4.5+ P = /12" P = 4.5+ P = 4.5+ Fugro Consultants, Inc. SANDY LEAN CLAY (CL), light gray and yellowish brown, stiff, with fine-grained sand POORLY GRADED SAND WITH CLAY AND GRAVEL (SP-SC), yellowish brown, moist, loose COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 28.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

38 LOG OF BORING NO. B4-10 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 19/12" STRATUM DESCRIPTION SURF. ELEVATION: POORLY GRADED SAND WITH CLAY AND GRAVEL (SP-SC), yellowish brown, moist, loose (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = 22 FAT CLAY (CH), light brown and gray, moist, stiff to very stiff, shaley, slickensided /12" 35 50/4" 100/0.75" LIMESTONE, light gray, very hard, dry, with intermittent shale seams, argillaceous '-40' 93/ 82 SHALE, gray, soft to hard, moist, calcareous LIMESTONE, light gray, very hard, dry, with intermittent shale seams /0.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 98/ /1.25" 45'-50' 65/ 33 Fugro Consultants, Inc. SHALE, gray, hard to very hard, moist, calcareous, with intermittent limestone layers COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 28.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

39 LOG OF BORING NO. B4-10 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2.5" 50'-55' 97/ 97 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, hard to very hard, moist, calcareous, with intermittent limestone layers (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF LIMESTONE, light gray, very hard, dry, with intermittent shale lenses /0.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 28.0 UPON COMPLETION: 8.5 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

40 LOG OF BORING NO. B4-11 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 3.0 P = 3.0 STRATUM DESCRIPTION SURF. ELEVATION: LEAN CLAY WITH SAND (CL), light gray and yellowish brown, moist to wet, soft to stiff, with iron stains and trace calcareous nodules LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 40 PLASTIC 13 PLASTICITY INDEX (PI), % 27 PASSING NO. 200 SIEVE, % 72 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = P = /12" P = 1.5 P = 0.5 POORLY GRADED SAND (SP), yellow, very loose, water bearing, with fine-grained sand N = /12" LEAN CLAY (CL), light gray, moist, soft, slickensided, with iron stains FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ P = /1" 15'-20' 100/ /0.5" 20'-25' 70/ 63 Fugro Consultants, Inc. LIMESTONE, light gray, hard to very hard, dry, argillaceous, with intermittent shale seams SHALE, gray, soft to hard, moist, slightly calcareous, with intermittent limestone seams LIMESTONE, light gray, very hard, dry, with occasional shale lenses SHALE, gray, medium hard, moist, calcareous COMPLETION DEPTH: 35.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 7.5 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

41 LOG OF BORING NO. B4-11 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2.5" 25'-30' 97/ 97 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, medium hard, moist, calcareous (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /3" 30'-35' 88/ 85 LIMESTONE, light gray, very hard, dry, with intermittent shale lenses /0.5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 Fugro Consultants, Inc. COMPLETION DEPTH: 35.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 7.5 UPON COMPLETION: 4.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

42 LOG OF BORING NO. B4-12 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.5 STRATUM DESCRIPTION SURF. ELEVATION: FILL, CLAY, brown, moist, soft, with, trace gravel LAYER ELEV./ DEPTH WATER CONTENT, % 23 LIQUID 43 PLASTIC 16 PLASTICITY INDEX (PI), % 27 PASSING NO. 200 SIEVE, % 96 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = 2.5 P = 3.75 P = /12" FILL, CLAY, dark brown, moist, soft to stiff FILL, SANDY CLAY, brown, moist, very soft to soft, trace gravel P = 4.0 P = P = P = /12" P = P = /12" CLAYEY SAND WITH GRAVEL (SC), reddish brown, slightly compact FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 P = 1.0 P = /12" N = 18 Fugro Consultants, Inc. SILTY SAND (SM), brown, dry, loose, with trace clay and organics POORLY GRADED SAND WITH GRAVEL (SP), tan, dry, slightly compact, with few clay lenses COMPLETION DEPTH: 80.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 25.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

43 LOG OF BORING NO. B4-12 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 33/12" SURF. ELEVATION: STRATUM DESCRIPTION POORLY GRADED GRAVEL (GP), tan, wet, slightly compact LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = 11 SANDY LEAN CLAY (CL), tan, moist to wet, very soft, with intermittent silty sand lenses and trace organics /12" CLAYEY SAND (SC), tan, wet, very loose to loose N = /12" SILTY CLAYEY SAND WITH GRAVEL (SC-SM), tan, wet, slightly compact N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 N = /6.75" Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH SAND (GP), tan, wet, compact, with trace clay lenses LIMESTONE, moderately weathered, tan, soft, moist, fractured, with intermittent gravel seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams SHALE, gray, hard to very hard, calcareous, with limestone seams COMPLETION DEPTH: 80.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 25.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

44 LOG OF BORING NO. B4-12 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.75" 50'-55' 97/ 85 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, hard to very hard, calcareous, with limestone seams (continued) LIMESTONE, light gray, hard to very hard, dry, with shale seams LAYER ELEV./ DEPTH WATER CONTENT, % 6 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF 145 UNCONFINED STRENGTH TSF SHALE, gray, hard to very hard, dry, calcareous, with intermittent limestone lenses /1.5" 55'-60' 98/ /0.75" '-65' 95/ 90 SHALE, gray and brown, soft to very hard, moist FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /4" 65'-70' 93/ /2.5" 70'-75' 97/ 97 Fugro Consultants, Inc. COMPLETION DEPTH: 80.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 25.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE c

45 LOG OF BORING NO. B4-12 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2.25" 75'-80' 97/ 97 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray and brown, soft to very hard, moist (continued) LAYER ELEV./ DEPTH WATER CONTENT, % 17 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF 113 UNCONFINED STRENGTH TSF /0.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 95 Fugro Consultants, Inc. COMPLETION DEPTH: 80.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 25.0 UPON COMPLETION: 25.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE d

46 LOG OF BORING NO. B4-15 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 4.5+ P = 4.5+ P = 1.0 P = 1.25 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, reddish brown, moist, soft, with gravel SANDY LEAN CLAY (CL), reddish brown, moist, soft, with trace gravel LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = /12" P = 4.0 P = P = 3.0 P = /12" P = P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 8 12/12" P = 0.75 P = 1.0 Fugro Consultants, Inc. SILTY CLAYEY SAND WITH GRAVEL (SC-SM), tan and light gray, wet, loose to compact COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

47 LOG OF BORING NO. B4-15 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 42/12" STRATUM DESCRIPTION SURF. ELEVATION: SILTY SAND (SM), tan, wet, compact LAYER ELEV./ DEPTH 25.0 WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /11" 100/1" POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, wet, dense, subangular to round, fine to coarse gravel, with medium fine to coarse sand LIMESTONE, tan to gray, hard to very hard, dry, weathered calcareous nodules, with shale lenses SHALE, gray, hard, moist, calcareous, with intermittent limestone seams /1.5" 35'-40' 80/ /0.75" LIMESTONE, light gray, hard to very hard, dry, with shale lenses SHALE, gray, very hard, moist, calcareous, with intermittent limestone seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 98/ /3" 45'-50' 95/ 95 Fugro Consultants, Inc. SHALE, gray, hard, moist, fissile COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

48 LOG OF BORING NO. B4-15 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH 50.0 WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: 14.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

49 LOG OF BORING NO. B4-16 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 4.5+ P = 4.5+ STRATUM DESCRIPTION SURF. ELEVATION: CLAYEY SAND WITH GRAVEL (SC), reddish brown, moist, slightly compact LAYER ELEV./ DEPTH WATER CONTENT, % 17 LIQUID 52 PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 4.5+ N = 24 POORLY GRADED GRAVEL WITH SAND (GP), reddish brown to reddish tan, dry, compact to dense, with intermittent clay seams /8.5" N = /5" LIMESTONE, moderately weathered, tan, soft to hard, moist, fractured, with intermittent clay seams N = 50/4" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /2.5" 100/1.75" 20'-25' 100/ 82 Fugro Consultants, Inc. LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE a

50 LOG OF BORING NO. B4-16 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.75" 25'-30' 98/ 63 STRATUM DESCRIPTION SURF. ELEVATION: LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF SHALE, gray, hard, moist, with intermittent limestone lenses /1.5" 30'-35' 98/ 58 LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams /0.75" 35'-40' 98/ /0.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 98/ /2.5" 45'-50' 95/ 95 Fugro Consultants, Inc. SHALE, gray to brown, hard, moist, fissile COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

51 LOG OF BORING NO. B4-16 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH 50.0 WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 50.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

52 LOG OF BORING NO. B4-17 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 1.5 P = 2.75 STRATUM DESCRIPTION SURF. ELEVATION: SANDY LEAN CLAY (CL), reddish gray, moist, soft, with fine-grained sand LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 38 PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = P = /11.5" N = 36 POORLY GRADED SAND (SP), yellow, dry, compact to very dense, with fine to coarse sand and fine angular to subangular gravel /8.5" LIMESTONE, tan, soft to hard, dry, weathered, fractured, with interbedded clay seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /1.5" 15'-20' 98/ /7" 20'-25' 70/ 48 Fugro Consultants, Inc. LIMESTONE, light gray, hard to very hard, dry, fossiliferous, fractured, with intermittent shale lenses SHALE, gray, soft, moist, calcareous, with intermittent limestone lenses LIMESTONE, light gray, very hard, dry, with intermittent shale lenses COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

53 LOG OF BORING NO. B4-17 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.5" 25'-30' 95/ 55 STRATUM DESCRIPTION SURF. ELEVATION: LIMESTONE, light gray, very hard, dry, with intermittent shale lenses (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /0.75" 30'-35' 90/ /5" 35'-40' SHALE, brown and gray, soft to very hard, moist, calcareous / /2.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 95/ /2.5" 45'-50' 87/ 83 Fugro Consultants, Inc. COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

54 LOG OF BORING NO. B4-17 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" 50'-55' 43/ 43 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, brown and gray, soft to very hard, moist, calcareous (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /1.5" 55'-60' 93/ /1.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 60.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

55 LOG OF BORING NO. B4-18 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 4.0 P = 2.5 P = 2.0 STRATUM DESCRIPTION SURF. ELEVATION: FILL, GRAVEL, light brown, dry, loose FILL, CLAY, brown and tan, moist, soft, with trace calcareous nodules LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 52 PLASTIC 18 PLASTICITY INDEX (PI), % 34 PASSING NO. 200 SIEVE, % 76 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = 2.0 9/12" CLAYEY SAND (SC), reddish brown, moist, loose, with trace gravel P = P = 4.5+ N = /1.5" POORLY GRADED GRAVEL WITH SAND (GP), reddish tan, moist to saturated, slightly compact CLAYEY SAND (SC), tan, wet, very dense POORLY GRADED GRAVEL WITH SAND (GP), tan, wet, dense, with intermittent clay seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ N = /4" N = 50/3" 100/2.75" Fugro Consultants, Inc. FAT CLAY WITH SAND (CH), tan, moist, very hard, calcareous, blocky LIMESTONE, moderately weathered, tan, soft to hard, moist, fractured, with intermittent clay seams LIMESTONE, light gray, hard, dry, with intermittent shale seams COMPLETION DEPTH: 20.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 9.5 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE

56 LOG OF BORING NO. B4-19 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.0 P = 1.5 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, reddish brown, moist, soft, with trace gravel LAYER ELEV./ DEPTH WATER CONTENT, % 24 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = P = P = /12" P = P = P = 0.75 P = /12" FILL, SILTY SAND, reddish brown, very loose, water bearing SANDY LEAN CLAY (CL), dark gray to brown, moist, soft, with trace calcareous nodules P = P = 2.0 P = P = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 P = 1.5 N = 50/4" 100/1.75" N = 50/5" Fugro Consultants, Inc. GRAVELLY LEAN CLAY WITH SAND (CL), brown and gray, moist to wet, soft to stiff, with fine to coarse sub angular to rounded gravel and fine sand LIMESTONE, moderately weathered, tan, hard to very hard, moist, fractured, with interbedded clay seams SHALE, light brown and gray, hard, moist, slickensided LIMESTONE, moderately weathered, tan, hard to very hard, moist, fractured, with interbedded clay seams COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

57 LOG OF BORING NO. B4-19 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.5" 25'-30' 97/ 57 STRATUM DESCRIPTION SURF. ELEVATION: LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams LAYER ELEV./ DEPTH 25.0 WATER CONTENT, % 6 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF 143 UNCONFINED STRENGTH TSF /1" 30'-35' 98/ 95 SHALE, gray and brown, soft to hard, moist, fissile /3" 35'-40' / /3" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 95/ /4" 45'-50' 93/ 93 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: DRY 19 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD PLATE b

58 LOG OF BORING NO. B4-19 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.5" 50'-55' 98/ 98 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray and brown, soft to hard, moist, fissile (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /2.25" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

59 LOG OF BORING NO. B4-20 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 4.5+ P = 4.5+ STRATUM DESCRIPTION SURF. ELEVATION: SANDY LEAN CLAY WITH GRAVEL (CL), brown, moist, stiff LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID 33 PLASTIC 14 PLASTICITY INDEX (PI), % 19 PASSING NO. 200 SIEVE, % 52 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 4.5+ P = 1.0 SILTY SAND WITH GRAVEL (SM), tan, dry, loose N = 11 28/12" N = 48 POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, slightly compact, dry to water bearing N = 50/4" 100/7" LIMESTONE, tan, soft, moist, weathered, fractured, with intermittent clay seams SHALE, light brown and gray, soft, moist, slickensided, with intermittent weathered limestone seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ P = /3" 100/1.5" 20'-25' 97/ 62 Fugro Consultants, Inc. LIMESTONE, tan, hard, dry, weathered, fractured, with clay seams LIMESTONE, light gray, hard to very hard, dry, fractured, with interbedded shale lenses SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.5 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

60 LOG OF BORING NO. B4-20 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/0.5" 25'-30' 99/ 93 SURF. ELEVATION: STRATUM DESCRIPTION SHALE, gray and brown, soft to hard, moist, fissile LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /3.75" 30'-35' 88/ /2" 35'-40' 70/ /1.75" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-45' 97/ /1.75" 45'-50' 78/ 78 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.5 UPON COMPLETION: 14.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

61 LOG OF BORING NO. B4-20 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/2" 50'-55' 90/ 90 STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray and brown, soft to hard, moist, fissile (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /2" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 70 Fugro Consultants, Inc. COMPLETION DEPTH: 55.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 8.5 UPON COMPLETION: 14.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

62 LOG OF BORING NO. B4-21 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.25 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SANDY CLAY, dark gray and brown, moist, very stiff, with fine-grained sand LAYER ELEV./ DEPTH WATER CONTENT, % 13 LIQUID 49 PLASTIC 16 PLASTICITY INDEX (PI), % 33 PASSING NO. 200 SIEVE, % 57 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 2.5 SANDY LEAN CLAY (CL), yellow, moist, soft P = 3.5 SANDY LEAN CLAY (CL), yellow, moist, soft /12" P = P = /12" P = 4.5+ FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /12" N = 50/3" 100/3.75" Fugro Consultants, Inc. CLAYEY SAND (SC), wet, compact to very dense, with fine-grained sand COMPLETION DEPTH: 20.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 13.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE

63 LOG OF BORING NO. B4-22 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.5 STRATUM DESCRIPTION SURF. ELEVATION: SANDY LEAN CLAY (CL), reddish brown, moist, soft LAYER ELEV./ DEPTH WATER CONTENT, % 16 LIQUID 39 PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 3.5 P = P = 4.0 P = /12" P = 2.0 P = 2.0 P = 2.5 N = 8 SILTY SAND (SM), reddish tan, dry, loose /12" 15 N = 14 57/12" POORLY GRADED SAND WITH GRAVEL (SP), tan, dry, loose to compact FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 30 18/12" N = 6 Fugro Consultants, Inc. COMPLETION DEPTH: 75.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 35.0 UPON COMPLETION: DRY 4 4 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

64 LOG OF BORING NO. B4-22 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 6/12" SURF. ELEVATION: STRATUM DESCRIPTION POORLY GRADED SAND (SP), reddish tan, dry, slightly compact to compact LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = /12" N = /12" N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 N = 8 68/12" N = 41 Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH SAND (GP), tan, wet, compact, fine to coarse, with angular to rounded gravel FAT CLAY (CH), light brown and gray, moist, hard, slickensided COMPLETION DEPTH: 75.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 35.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

65 LOG OF BORING NO. B4-22 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 78/12" STRATUM DESCRIPTION SURF. ELEVATION: FAT CLAY (CH), light brown and gray, moist, hard, slickensided (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF /3" LIMESTONE, light gray, hard to very hard, dry SHALE, gray, very hard, moist, with intermittent limestone seams /0.75" 60'-65' 88/ 50 LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses /2" SHALE, gray, hard to very hard, moist, with intermittent limestone lenses and seams FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-70' 93/ /1" 70'-75' 90/ 90 Fugro Consultants, Inc. COMPLETION DEPTH: 75.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 35.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

66 LOG OF BORING NO. B4-22 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/1.75" SURF. ELEVATION: STRATUM DESCRIPTION LAYER ELEV./ DEPTH 75.0 WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 95 Fugro Consultants, Inc. COMPLETION DEPTH: 75.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 35.0 UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE d

67 LOG OF BORING NO. B4-23 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.5 P = 4.0 STRATUM DESCRIPTION SURF. ELEVATION: FILL, CLAYEY SAND, reddish brown, moist, loose, with trace gravel LAYER ELEV./ DEPTH WATER CONTENT, % 16 LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % 50 UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF P = 2.5 N = 13 SILTY SAND (SM), reddish brown, moist to dry, loose /12" CLAYEY SAND (SC), reddish brown, moist, loose P = 2.5 P = 2.5 P = P = /12" SILTY SAND (SM), reddish tan, dry, very loose to slightly compact, with intermittent clay lenses and trace gravel P = /12" 15 17/12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 12 10/12" N = 9 Fugro Consultants, Inc. POORLY GRADED GRAVEL WITH SAND (GP), reddish brown, dry, loose, with fine angular to rounded gravel POORLY GRADED SAND (SP), reddish tan, dry, loose to slightly compact, fine to medium sand COMPLETION DEPTH: 95.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 30.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE a

68 LOG OF BORING NO. B4-23 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 25/12" STRATUM DESCRIPTION SURF. ELEVATION: POORLY GRADED SAND (SP), reddish tan, dry, loose to slightly compact, fine to medium sand (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = /12" N = 66 POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, moist to wet, slightly compact to compact, with fine to coarse angular to sub rounded gravel, and medium to coarse sand /12" N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 45 N = 38 18/12" N = 30 Fugro Consultants, Inc. CLAYEY SAND (SC), reddish tan, moist, loose, with intermittent silty sand partings POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, moist, compact, with intermittent clay lenses and sand partings COMPLETION DEPTH: 95.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 30.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE b

69 LOG OF BORING NO. B4-23 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 41/12" STRATUM DESCRIPTION SURF. ELEVATION: POORLY GRADED GRAVEL WITH CLAY AND SAND (GP-GC), tan, moist, compact, with intermittent clay lenses and sand partings (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = 10 SANDY LEAN CLAY (CL), tan, moist, soft, with interbedded sand partings /12" POORLY GRADED SAND WITH GRAVEL (SP), tan, moist, slightly compact, with fine to coarse sand, and fine sub-angular to rounded gravel N = /0.5" FAT CLAY (CH), light brown and gray, moist, stiff, slickensided LIMESTONE, light gray, very hard, dry SHALE, gray, soft to very hard, moist /5" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-70' 17/ /3.75" 70'-75' 93/ 93 Fugro Consultants, Inc. COMPLETION DEPTH: 95.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 30.0 UPON COMPLETION: 25.0 KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE c

70 LOG OF BORING NO. B4-23 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % 100/3" 75'-80' STRATUM DESCRIPTION SURF. ELEVATION: SHALE, gray, soft to very hard, moist (continued) LAYER ELEV./ DEPTH WATER CONTENT, % LIQUID PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 80/ /3" 80'-85' 92/ /0.75" 85'-90' 100/ /1" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ '-95' 95/ /1.5" Fugro Consultants, Inc. LIMESTONE, gray, hard to very hard, moist, argillaceous, with interbeddded shale lenses COMPLETION DEPTH: 95.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 30.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE d

71 LOG OF BORING NO. B4-24 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 2.25 P = 0.5 N = 13 STRATUM DESCRIPTION SURF. ELEVATION: SANDY LEAN CLAY (CL), reddish brown, moist, soft POORLY GRADED SAND WITH GRAVEL (SP), reddish brown, dry, loose POORLY GRADED SAND (SP), reddish brown, dry, very loose to loose, with intermittent clay lenses LAYER ELEV./ DEPTH WATER CONTENT, % 15 5 LIQUID 29 NP PLASTIC 15 NP PLASTICITY INDEX (PI), % 14 NP PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF N = /12" N = 5 8 N = /12" N = 4 SANDY LEAN CLAY (CL), brown, moist, soft FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/ /12" N = 12 64/12" Fugro Consultants, Inc. POORLY GRADED SAND (SP), tan, dry, loose to compact COMPLETION DEPTH: 20.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: DRY UPON COMPLETION: DRY KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE

72 LOG OF BORING NO. B4-25 North Tarrent Express-Segment 4 NORTHING: EASTING: PROJECT NO DEPTH, FT SYMBOL SAMPLES POCKET PEN, tsf Blows/ft. REC./RQD, % P = 3.5 P = 0.5 N = 25 STRATUM DESCRIPTION SURF. ELEVATION: FILL, SAND, reddish tan, moist, loose, with fine to medium sand and fine aungular gravel POORLY GRADED SAND (SP), reddish tan, dry, slightly compact, silty LAYER ELEV./ DEPTH WATER CONTENT, % 10 4 LIQUID 25 PLASTIC PLASTICITY INDEX (PI), % PASSING NO. 200 SIEVE, % UNIT DRY WEIGHT, PCF UNCONFINED STRENGTH TSF 5 N = 16 31/12" POORLY GRADED SAND WITH GRAVEL (SP), reddish tan, dry, loose to slightly compact, fine to coarse, with fine angular to sub-rounded gravel N = N = /12" WELL GRADED SAND (SW), tan, dry, slightly compact to compact N = /12" FUGRO STD GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/26/10 20 N = 11 41/12" Fugro Consultants, Inc. COMPLETION DEPTH: 20.0 DATE DRILLED: to WATER LEVEL / SEEPAGE: 18.0 UPON COMPLETION: KEY: P = Pocket Penetrometer Note: All depths are measured in feet. Coordinate System: NAD 83 PLATE

73 TERMS AND SYMBOLS USED ON BORING LOGS FOR SOIL SOIL TYPES CLAY (CH) SHALY CLAY (CH) CLAY (CL) SANDY CLAY (CL) Well-Graded SAND (SW) Poorly-Graded SAND (SP) SILTY SAND (SM) CLAYEY SAND (SC) Well-Graded GRAVEL (GW) Poorly-Graded GRAVEL (GP) SILTY GRAVEL (GM) FILL Material U.S.STANDARD SIEVE 12" 3" 3/4" GRAVEL SAND BOULDERS COBBLES COARSE FINE COARSE MEDIUM FINE SOIL GRAIN SIZE IN MILIMETERS (2) STRENGTH OF COHESIVE SOILS CONSISTENCY UNDRAINED COMPRESSIVE STRENGTH Tons Per Sq. Ft. SOIL GRAIN SIZE SILT CLAY DENSITY OF GRANULAR SOILS NUMBER OF BLOWS PER FT., N RELATIVE DENSITY (2) Very Soft Less Than Very Loose Soft 0.25 to Loose Firm 0.5 to Medium Stiff 1.00 to Dense Very Stiff 2.00 to 4.00 Over 50 Very Dense Hard greater than 4.00 (1) DESCRIPTIVE TERMS FOR SOIL DESCRIPTION CRITERIA MOISTURE Stratified Laminated Fissured Slickensided Blocky Lensed Alternating layers of varying material or color with layers at least 6 mm thick. Alternating layers of varying material or color with the layers less than 6 mm thick. Breaks along definite planes of fracture with little resistance to fracturing. Fracture planes appear polished or glossy, sometimes striated. Cohesive soil that can be broken down into small angular lumps which resist further breakdown. Inclusions of small pockets of different soils. Dry Moist Very Moist Wet Parting Seam Layer Trace Few Little With No water evident in sample; fines less than plastic limit. Sample feels damp; fines near the plastic limit Water visible on sample; fines greater plastic limit and less than liquid limit Sample bears free water; fines greater than liquid limit. INCLUSIONS Inclusion <1/8" thick extending through sample Inclusion 1/8" to 3" thick extending through sample. Inclusion >3" thick extending through sample. <5% of sample. 5% to 10% of sample. 15 to 25% of sample. 15% to 29% of sample. (1) NOTE: Information on each boring log is a compilation of subsurface conditions and soil and rock classifications obtained from the field as well as from laboratory testing of samples. Strata have been interpreted from commonly accepted procedures. The stratum lines on the logs may be transitional and approximate in nature. Water level measurements refer only to those observed at the times and places indicated, and may vary with time, geologic condition or construction activity. Fugro Consultants, Inc. REFERENCES: 1) ASTM D ) Peck, Hanson and Thornburn, (1974), Foundation Engineering. PLATE 29

74 TERMS AND SYMBOLS USED ON BORING LOGS FOR ROCK ROCK TYPES SAMPLER TYPES LIMESTONE SHALE SANDSTONE Thinwalled Tube Rock Core WEATHERED LIMESTONE WEATHERED SHALE WEATHERED SANDSTONE Standard Penetration Test Auger Sample HIGHLY WEATHERED LIMESTONE ARGILLACEOUS LIMESTONE MARL THD Cone Penetration Test Bag Sample SOLUTION & VOID CONDITIONS WEATHERING GRADES OF ROCKMASS (1) Void Cavities Vuggy Vesicular Porous Cavernous Interstice; a general term for pore space or other openings in rock. Small solutional concavities. Containing small cavities, usually lined with a mineral of different composition from that of the surrounding rock. Containing numerous small, unlined cavities, formed by expansion of gas bubbles or steam during solidification of the rock. Containing pore, interstices, or other openings which may or may not interconnect. Containing cavities or caverns, sometimes quite large. Most frequent in limestones and dolomites. Slightly Moderately Highly Completely Residual Soil Discoloration indicates weathering of rock material and discontinuity surfaces. Less than half of the rock material is decomposed or disintegrated to a soil. More than half of the rock material is decomposed or disintegrated to a soil. All rock material is decomposed and/or disintegrated to soil.the original mass structure is still largely intact. All rock material is converted to soil.the mass structure and material fabric are destroyed. HARDNESS BEDDING THICKNESS (2) Friable Low Hardness Moderately Hard Very Hard Crumbles under hand pressure Can be carved with a knife Can be scratched easily with a knife Cannot be scratched with a knife Very Thick Thick Thin Very Thin Laminated Thinly-Laminated >4' 2'-4' 2"-2' 1/2"-2" 0.08"-1/2" <0.08" JOINT DESCRIPTION SPACING INCLINATION Very Close <2" Horizontal 0-5 Close 2"-12" Shallow 5-35 Medium Close 12"-3' Moderate Wide >3' Steep Vertical SURFACES Slickensided Polished, grooved Smooth Planar Irregular Undulating or granular Rough Jagged or pitted Fugro Consultants, Inc. NOTE: Information on each boring log is a compilation of subsurface conditions and soil and rock classificaitons obtained from the field as well as from laboratory testing of samples. Strata have been interpreted by commonly accepted procedures. The stratum lines on the logs may be transitional and approximate in nature. Water level measurements refer only to those observed at the times and places indicated, and may vary with time, geologic condition or construction activity. REFERENCES: 1) British Standard(1981) Code of Practice for Site Investigation BS ) The Bridge Division, Texas Highway Dept. Foundation Exploration & Design Manual, 2nd Edition,revised June,1974. PLATE 30

75 Project No APPENDIX - C A KEY TO TERMS AND SYMBOLS USED ON TXDOT BORING LOGS WINCORE BORING LOGS

76 TERMS AND SYMBOLS USED ON TxDOT BORING LOGS SOIL TYPES CH, Fat Clay Sand ROCK TYPES Limestone CL, Lean Clay Gravel Shale ML, Silt Fill/Other Clayshale/Other SOIL GRAIN SIZE U.S.STANDARD SIEVE 6" 3" 3/4" GRAVEL SAND BOULDERS COBBLES SILT CLAY COARSE FINE COARSE MEDIUM FINE SOIL GRAIN SIZE IN MILLIMETERS (1) STRENGTH OF GRANULAR SOILS STRENGTH OF COHESIVE SOILS (1) (1) BEDROCK HARDNESS THD Penetrometer THD Penetrometer THD Penetrometer CONSISTENCY (blows/ft or blows/300mm) DENSITY (blows/ft or blows/300mm) HARDNESS (blows/ft or blows/300mm) Very Loose Loose Slightly Compact 0 to 8 8 to to 40 Very Soft Soft Stiff 0 to 8 8 to to 40 Very Hard Hard 0" - 2"/100 (0-50mm/100) 1" - 5"/100 (25-125mm/100) Compact Dense 40 to to 5"/100 (125mm/100) Very Stiff Hard 40 to to 5"/100 (125mm/100) Soft 4" - 6"/100 ( mm/100) Very Dense 5"/100 to 0"/100 (125mm/100 to 0mm/100) Very Hard 5"/100 to 0"/100 (125mm/100 to 0mm/100) 1) TxDOT Geotechnical Manual, Chapter 3 - Soil and Bedrock Classification & Logging (3-15) ASTM D 2488 TABLE 7 Criteria for Describing Structure Stratified Laminated Fissured Slickensided Blocky Lensed Description Homogeneous Criteria Alternating layers of varying material or color with layers at least 6 mm thick; note thickness Alternating layers of varying material or color with the layers less than 6mm thick; note thickness Breaks along definite planes of fracture with little resistance to fracturing Fracture planes appear polished or glossy, sometimes striated Cohesive soil that can be broken down into small angular lumps which resist further breakdown Inclusion of small pockets of different soils, such as small lenses of sand scattered through a mass of clay; note thickness Same color and appearance throughout Criteria for Describing Inclusions Description Parting Seam Layer Description Criteria Inclusion <1/8" thick extending through sample Inclusion 1/8" to 3" thick extending through sample Inclusion >3" thick extending through sample Terms used in Addtional Remarks on Wincore Logs PP SPT REC RQD Q U Criteria Pocket Penetration Test (tsf) Modified Standard Penetration Test (bpf) Rock Core Recovery (%) Rock Quality Designation, ASTM (D 6032) Unconsolidated Undrained Triaxial Test (tsf) Unconfined Compression Test (tsf)

77 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-1 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/26/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) 5 10 L O G Texas Cone Penetrometer 50 (4.5) 50 (4) 50 (1.25) 50 (1) Strata Description FILL, SAND, reddish tan and brown, moist, loose to dense (FILL) LIMESTONE, moderately weathered, tan, soft to hard, moist LIMESTONE, light gray, hard, dry. Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = 44 PP = 2.5 tsf % Passing No. 200 Sieve = PP = 2.0 tsf PP = 4.5+ tsf N = 50/5in. 10'-15' REC=97%/ RQD=65% (1.5) 50 (1.25) SHALE, gray to brown, soft to hard, moist '-20' REC=75%/ RQD=75% (2) 50 (2) '-25' REC=87%/ RQD=87% (1.5) 50 (1) 25'-30' REC=80%/ RQD=80% (1.5) 50 (1.25) 30'-35' REC=95%/ RQD=95% (1.25) 50 (0.75) 35'-40' REC=88%/ RQD=88% (1.25) 50 (1.25) 40'-45' REC=97%/ RQD=67% Remarks: Boring was advanced to the 10 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 10 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

78 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-1 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/26/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray to brown, soft to hard, moist. Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (0.25) 50 (0.25) LIMESTONE, light gray, very hard, dry Remarks: Boring was advanced to the 10 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 10 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

79 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-2 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/31/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) 5 L O G Texas Cone Penetrometer 50 (4) 50 (5) Strata Description FILL, HMAC (10 inches) FILL, SAND, reddish brown and brown, moist, loose. (FILL) CLAY, sandy, tan, moist, hard. (CL) LIMESTONE, moderately weathered, tan, soft, moist, fractured, with intermittent clay seams Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = 39 PP = 4.5 tsf % Passing No. 200 Sieve = 61 PP = 4.5+ tsf N = 50/3in (2) 50 (0.75) LIMESTONE, light gray, hard to very hard, dry, fractured, with intermittent shale lenses '-15' REC=65%/ RQD=48% (1) 50 (1.25) SHALE, gray, soft, moist, calcareous, with intermittent limestone seams 15'-20' REC=97%/ RQD=63% LIMESTONE, light gray, hard to very hard, dry, fractured, with interbedded shale seams (0.5) 50 (0.25) '-25' REC=98%/ RQD=55% (0.75) 50 (0.25) 25'-30' REC=100%/ RQD=77% (0.5) 50 (0.5) SHALE, gray to brown, soft to hard, moist, fissile '-35' REC=98%/ RQD=88% (0.75) 50 (1) 35'-40' REC=97%/ RQD=97% (0.5) 50 (1) 40'-45' REC=85%/ RQD=85% Remarks: Boring was advanced to the 10 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 10 ft, the boring was advanced to its completion depth of 50 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

80 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-2 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/31/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray to brown, soft to hard, moist, fissile Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks (1) 50 (1) 45'-50' REC=97%/ RQD=97% (1.25) 50 (0.75) Remarks: Boring was advanced to the 10 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 10 ft, the boring was advanced to its completion depth of 50 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

81 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-3 Structure North Tarrant Express Station Offset 1.13 LT District Fort Worth Date 3/13/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) 5 L O G Texas Cone Penetrometer 50 (5.5) 50 (4.25) Strata Description FILL, SAND, brown, compact, moist, with trace calcareous nodules. (FILL) CLAY, brown, very stiff, moist, with fine grained sand. (CH) CLAY, tan, stiff to hard, dry, calcareous. (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = 37 PP = 3.0 tsf % Passing No. 200 Sieve = N = 44 bpf N = 47 bpf (6) 33 (6) 12.3 N = 24 bpf (6) 30 (6) 15.0 N = 31 bpf (6) 32 (6) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

82 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-4 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/29/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 6 (6) 5 (6) 11 (6) 11 (6) 50 (5) 50 (3.25) Strata Description FILL, HMAC (12 inches) CLAY, dark brown to brown, moist, soft, with trace calcareous nodules. (CH) CLAY, brown, moist, stiff (CH) CLAY, sandy, light brown, moist, stiff (CL) SAND, tan, dry to saturated, slightly compact GRAVEL, tan, wet, dense Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 21.8 PP = 2.0 tsf Additional Remarks 19.2 PP = 1.75 tsf PP = 3.0 tsf 26.4 % Passing No. 200 Sieve = PP = 4.0 tsf PP = 4.5 tsf PP = 4.5 tsf % Passing No. 200 Sieve = % Passing No. 200 Sieve = 8 N = (1.25) 50 (0.25) LIMESTONE, moderately weathered, tan, hard, moist, fractured, with intermittent clay seams SHALE, gray, hard, moist, calcareous, with intermittent limestone seams N = 50/4in (0.25) 50 (0.25) LIMESTONE, light gray, very hard, dry, with intermittent shale lenses SHALE, gray, hard, moist, calcareous, with intermittent limestone lenses 25'-30' REC=100%/ RQD=87% (1.75) 50 (2) 30'-35' REC=93%/ RQD=75% (0.75) 50 (0.25) LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses '-40' REC=98%/ RQD=75% (0.5) 50 (0.25) SHALE, gray, very hard, moist, calcareous, with intermittent limestone lenses 40'-45' REC=98%/ RQD=78% Remarks: Boring was advanced to the 25 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 25 ft, the boring was advanced to its completion depth of 60 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

83 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-4 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/29/10 Grnd. Elev ft GW Elev ft Elev. (ft) 45 L O G Texas Cone Penetrometer 50 (0.5) 50 (0.25) Strata Description SHALE, gray, very hard, moist, LIMESTONE, calcareous, light with gray, intermittent very hard, limestone dry, with intermittent lenses shale lenses SHALE, gray, soft to very hard, moist, calcareous, with intermittent limestone lenses Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks 45'-50' REC=98%/ RQD=92% (0.5) 50 (0.25) 50'-55' REC=100%/ RQD=95% (1) 50 (0.5) 55'-60' REC=98%/ RQD=98% (1) 50 (0.75) Remarks: Boring was advanced to the 25 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 25 ft, the boring was advanced to its completion depth of 60 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

84 DRILLING LOG 1 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-5 Structure North Tarrant Express Station Offset 7.77 LT District Fort Worth Date 3/23/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 4 (6) 5 (6) 5 (6) 4 (6) Strata Description FILL, clay, brown, moist, soft to very stiff, with trace gravel (FILL) FILL, sand, tan, wet, loose (FILL) FILL, clay, brown, moist, soft to stiff (FILL) FILL, sand, tan to reddish tan, moist, loose, with trace gravel (FILL) FILL, sand, reddish tan, moist to wet, slight compact, with interbedded clay seams and cemented sand fragments Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 16 PP = 3.0 tsf Additional Remarks % Passing No. 200 Sieve = PP = 3.5 tsf 22.1 PP = 1.25 tsf PP = 3.0 tsf % Passing No. 200 Sieve = 45 PP = 1.0 tsf 17.5 N = 14 bpf (6) 7 (6) FILL, brown and gray, moist, soft to stiff, with few calcareous particles (FILL) (6) 13 (6) % Passing No. 200 Sieve = 69 PP = 3.75 tsf 25 9 (6) 8 (6) 13.0 N = 14 bpf (6) 12 (6) 22.8 PP = 4.0 tsf PP = 4.0 tsf (6) 18 (6) % Passing No. 200 Sieve = 97 PP = 4.0 tsf (6) 18 (6) 26.0 PP = 4.25 tsf PP = 4.25 tsf Remarks: Boring was advanced to the 90 ft depth using dry drilling technology and groundwater was encountered at the 45 ft depth. Below 90 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

85 DRILLING LOG 2 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-5 Structure North Tarrant Express Station Offset 7.77 LT District Fort Worth Date 3/23/10 Grnd. Elev ft GW Elev ft Elev. (ft) 45 L O G Texas Cone Penetrometer 9 (6) 10 (6) Strata Description FILL, brown and gray, moist, soft to stiff, with few calcareous particles (FILL) CLAY, brown and gray, moist to saturated, soft (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) PP = 2.0 tsf Additional Remarks PP = 0.75 tsf PP = 1.0 tsf 50 7 (6) 7 (6) % Passing No. 200 Sieve = (6) 38 (6) SAND, tan, wet, loose, slightly compact (SP) GRAVEL, tan, wet compact to dense (GP-GC) 14.7 N = 30 bpf 55'-60' REC=92%/ RQD=80% (6) 7 (6) CLAY, gray and brown, moist, soft, trace calcareous nodules (CL) % Passing No. 200 Sieve = 80 N = 11 bpf (6) 8 (6) CLAY, brown and gray, wet, very soft to soft (CL) % Passing No. 200 Sieve = 72 PP = 0.5 tsf 20.7 PP = 0.5 tsf (6) 5 (6) CLAY, sandy, gray and brown, wet, soft (CL) PP = 0.5 tsf % Passing No. 200 Sieve = (6) 5 (6) PP = 0.5 tsf (6) 50 (5) GRAVEL, tan, moist, compact to dense, with fat clay seams. (GP-GC) N = 67 bpf Remarks: Boring was advanced to the 90 ft depth using dry drilling technology and groundwater was encountered at the 45 ft depth. Below 90 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

86 DRILLING LOG 3 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-5 Structure North Tarrant Express Station Offset 7.77 LT District Fort Worth Date 3/23/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description GRAVEL, tan, moist, compact to dense, with fat clay seams. (GP-GC) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks N = 94 bpf (3.25) 50 (2.75) (0.5) 50 (0.25) SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, very hard, SHALE, dry gray and brown, soft, moist, calcareous, with intermittent limestone seams N = 60 bpf 90'-95' REC=98%/ RQD=83% (2.5) 50 (2) '-100' REC=92%/ RQD=85% (1) 50 (1) Remarks: Boring was advanced to the 90 ft depth using dry drilling technology and groundwater was encountered at the 45 ft depth. Below 90 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

87 DRILLING LOG 1 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-6 Structure North Tarrant Express Station Offset 2.14 LT District Fort Worth Date 3/24/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 11 (6) 4 (6) 18 (6) 6 (6) Strata Description FILL, CLAY, reddish tan and brown, moist, soft, with trace gravel and intermittent sand seams (FILL) FILL, CLAY, brown, moist, soft, with trace calcareous nodules (FILL) FILL, SAND, reddish tan, moist, loose to dense, with few cemented sand fragments (FILL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 15.3 PP = 3.5 tsf PP = 2.0 tsf PP = 1.5 tsf 16.5 PP = 3.5 tsf PP = 3.0 tsf PP = 3.0 tsf PP = 2.5 tsf 24.5 PP = 4.5+ tsf Additional Remarks PP = 0.5 tsf (5.5) 50 (2.25) % Passing No. 200 Sieve = (6) 15 (6) FILL, CLAY, tan and brown, moist, stiff to very stiff (FILL) 18.5 N = 25 bpf (6) 11 (6) N = 11 bpf % Passing No. 200 Sieve = (6) 10 (6) CLAY, dark brown and gray, moist, soft to stiff, with trace calcareous nodules (CL) 19.5 N = 8 bpf 19.8 PP = 4.0 tsf 35 9 (6) 12 (6) PP = 3.5 tsf % Passing No. 200 Sieve = (6) 17 (6) PP = 4.5 tsf Remarks: Boring was advanced to the 85 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Below 85 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

88 DRILLING LOG 2 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-6 Structure North Tarrant Express Station Offset 2.14 LT District Fort Worth Date 3/24/10 Grnd. Elev ft GW Elev ft Elev. (ft) 45 L O G Texas Cone Penetrometer 14 (6) 14 (6) Strata Description CLAY, dark brown and gray, moist, soft to stiff, with trace calcareous nodules (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 18.0 PP = 3.25 tsf PP = 3.25 tsf Additional Remarks % Passing No. 200 Sieve = (6) 14 (6) PP = 3.0 tsf (6) 8 (6) CLAY, light brown and gray, moist to wet, soft, with trace calcareous nodules (CL) PP = 1.75 tsf % Passing No. 200 Sieve = (6) 17 (6) CLAY, sandy, light brown, wet, soft, with trace calcareous nodules (CL) SAND, light brown, wet, slightly compact (SC) 16.8 PP = 1.0 tsf PP = 0.5 tsf (6) 26 (6) SAND, tan, moist to wet, loose to compact, with intermittent clayey sand seams (SP) 14.2 N = 10 bpf 15.4 N = 21 bpf (6) 49 (6) GRAVEL, tan, wet, compact to dense, with few clay seams (GP-GC) 10.3 N = 42 bpf (5.5) 34 (6) 8.5 N = 55 bpf (3) 50 (3) Remarks: Boring was advanced to the 85 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Below 85 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

89 DRILLING LOG 3 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-6 Structure North Tarrant Express Station Offset 2.14 LT District Fort Worth Date 3/24/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray and brown, soft to very hard, moist, calcareous, with intermittent limestone seams Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (2) 50 (1.5) 16.0 N = 69 bpf 85'-90' REC=93%/ RQD=85% (0.25) 50 (0.25) 90'-95' REC=100%/ RQD=98% (0.5) 50 (0.25) 95'-100' REC=87%/ RQD=60% (0.5) 50 (0.25) Remarks: Boring was advanced to the 85 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Below 85 ft, the boring was advanced to its completion depth of 100 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

90 DRILLING LOG 1 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-7 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/19/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 6 (6) 7 (6) 9 (6) 10 (6) Strata Description FILL, CLAY, dark brown, moist, soft, with trace gravel (FILL) CLAY, brown, moist, soft to stiff, with trace calcareous nodules (CH) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 2.5 tsf PP = 2.0 tsf % Passing No. 200 Sieve = PP = 3.5 tsf PP = 3.75 tsf 20.3 PP = 3.5 tsf PP = 3.5 tsf PP = 3.5 tsf 15 8 (6) 11 (6) % Passing No. 200 Sieve = PP = 3.5 tsf (6) 12 (6) PP = 3.25 tsf (6) 9 (6) CLAY, light brown and gray, moist to saturated, soft, with trace calcareous nodules (CL) PP = 1.5 tsf PP = 1.75 tsf PP = 0.75 tsf 30 4 (6) 5 (6) PP = 1.0 tsf (6) 4 (6) CLAY, light brown and gray, moist to wet, very soft to soft (CL) % Passing No. 200 Sieve = 60 PP = 0.5 tsf (6) 3 (6) SAND, clayey, light brown and gray, wet, very loose (SC-SM) % Passing No. 200 Sieve = 48 PP = 0.5 tsf Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 23 ft depth. Below 65 ft, the boring was advanced to its completion depth of 85 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

91 DRILLING LOG 2 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-7 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/19/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SAND, clayey, light brown and gray, wet, very loose (SC-SM) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks 18.5 N = 12 bpf (6) 10 (6) SAND, tan, wet, loose to slightly compact (SP) (2) 50 (2) GRAVEL, tan, moist, compact to very dense (GP) 14.5 N = 81 bpf 8.9 N = 65 bpf (6) 50 (4.5) SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams 15.7 N = 54 bpf (2.25) 50 (1.5) (0.5) 50 (0.25) LIMESTONE, light gray, very hard, dry, with interbedded shale lenses SHALE, brown and gray, soft to very hard, moist, slightly calcareous, fossiliferous '-70' REC=90%/ RQD=83% (0.5) 50 (0.25) 70'-75' REC=98%/ RQD=92% (0.5) 50 (0.5) 75'-80' REC=98%/ RQD=98% (1) 50 (0.75) 80'-85' REC=98%/ RQD=98% Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 23 ft depth. Below 65 ft, the boring was advanced to its completion depth of 85 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

92 DRILLING LOG 3 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-7 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/19/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, brown and gray, soft to very hard, moist, slightly calcareous, fossiliferous Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (1) 50 (0.75) Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 23 ft depth. Below 65 ft, the boring was advanced to its completion depth of 85 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

93 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-8 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/14/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 24 (6) 30 (6) Strata Description SAND, clayey, reddish brown, moist, loose (SC) SAND, silty, reddish tan, moist, loose (SM) SAND, tan, slightly compact to compact, water bearing, with fine angular to rounded gravel (SP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = N = 13 bpf N = 14 bpf 13.2 N = 29 bpf (6) 16 (6) GRAVEL, tan, wet, sligthly compact, with medium to coarse sand (GP-GC) 10.4 N = 22 bpf (6) 50 (2) 50 (3) 50 (2.5) CLAY, light brown to gray, moist, stiff to very stiff, slickensided (CH) LIMESTONE, tan, hard, moist, weathered, fractured, with intermittent clay seams SHALE, gray, soft, moist, calcareous, with intermittent limestone seams 10.4 N = 32 bpf 20'-25' REC=90%/ RQD=58% (1) 50 (0.75) LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams SHALE, gray, hard, moist, fissile 25'-30' REC=97%/ RQD=83% (0.5) 50 (0.75) 30'-35' REC=80%/ RQD=80% (1.25) 50 (1) LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams 35'-40' REC=97%/ RQD=65% (0.5) 50 (0.25) SHALE, gray, soft to hard, moist 40'-45' REC=98%/ RQD=70% Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 4 ft depth. Below 20 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

94 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-8 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/14/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray, soft to hard, moist Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (0.5) 50 (0.25) LIMESTONE, light gray, very hard, dry, with interbedded cemented SHALE, lensesgray, soft to hard, moist, calcareous, with intermittent limestone seams Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 4 ft depth. Below 20 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

95 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-9 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/14/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 7 (6) 8 (6) 4 (6) 5 (6) Strata Description FILL, SANDY CLAY, dark brown, moist, soft (FILL) CLAY, light brown, moist, soft, with trace calcareous nodules (CH) CLAY, light brown, moist, soft (CL) SAND, reddish tan, moist, loose (SP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 2.5 tsf PP = 2.0 tsf PP = 2.0 tsf 17.8 PP = 2.0 tsf PP = 2.5 tsf 15.7 % Passing No. 200 Sieve = 6 N = 8 bpf (1.5) 50 (0.5) 50 (0.5) 50 (1.25) GRAVEL, tan, wet, compact (GP) LIMESTONE, tan, hard to very hard, dry, weathered, fractured LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses 12.8 N = 27 bpf 20'-25' REC=93%/ RQD=72% SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams (1) 50 (0.5) SHALE, gray, soft, moist, fissile 25'-30' REC=98%/ RQD=98% (2.5) 50 (5) 30'-35' REC=87%/ RQD=72% (0.5) 50 (0.5) 50 (0.5) 50 (0.25) SHALE, gray, soft, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, hard to very hard, dry, with interbedded shale lenses SHALE, gray, soft to hard, moist, calcareous LIMESTONE, light gray, very hard, dry, with interbedded shale seams 35'-40' REC=98%/ RQD=48% 40'-45' REC=93%/ RQD=63% Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 8 ft depth. Below 20 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

96 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-9 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/14/10 Grnd. Elev ft GW Elev ft 455. Elev. (ft) 45 L O G Texas Cone Penetrometer 50 (0.5) 50 (0.25) Strata Description LIMESTONE, light gray, very hard, dry, with interbedded shale seams SHALE, gray, very hard, moist, calcareous, with intermittent limestone seams Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks 45'-50' REC=98%/ RQD=85% (1) 50 (1) SHALE, gray, hard to very hard, moist, fissile 50'-55' REC=97%/ RQD=97% (1.5) 50 (1) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 8 ft depth. Below 20 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

97 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-10 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/4/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 7 (6) 8 (6) 7 (6) 7 (6) Strata Description FILL, SANDY CLAY, reddish brown, moist, soft, with fine-grained sand, iron stains, and fine rounded to subrounded gravel (FILL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 3.5 tsf 15.7 PP = 4.5+ tsf 12.3 PP = 4.5+ tsf PP = 4.5 tsf 11.0 PP = 4.5+ tsf 12.2 PP = 4.5+ tsf 14.6 PP = 4.5+ tsf (6) 7 (6) FILL, CLAY, light gray, moist, soft, with fine grained sand (FILL) % Passing No. 200 Sieve = PP = 4.25 tsf (6) 11 (6) CLAY, sandy, light gray and yellowish brown, stiff, with fine grained sand (CL) % Passing No. 200 Sieve = PP = 4.5+ tsf (6) 10 (6) SAND, yellowish brown, moist, loose (SP-SC) % Passing No. 200 Sieve = PP = 4.5+ tsf (6) 25 (6) CLAY, light brown and gray, moist, stiff to very stiff, shaley, slickensided (CH) N = 22 bpf (2) 25 (2) 50 (0.5) 50 (0.25) 50 (0.25) 50 (0.25) LIMESTONE, light gray, very hard, dry, with intermittent shale seams, argillaceous SHALE, gray, soft to hard, moist, calcareous LIMESTONE, light gray, very hard, dry, with intermittent shale seams '-40' REC=93%/ RQD=82% 40'-45' REC=98%/ RQD=75% Remarks: Boring was advanced to the 35 ft depth using dry drilling technology and groundwater was encountered at the 28 ft depth. Below 35 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

98 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-10 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/4/10 Grnd. Elev ft GW Elev ft Elev. (ft) 45 L O G Texas Cone Penetrometer 50 (0.75) 50 (0.5) Strata Description LIMESTONE, light gray, very hard, dry, with intermittent shale seams SHALE, gray, hard to very hard, moist, calcareous, with intermittent limestone layers Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks 45'-50' REC=65%/ RQD=33% (1.5) 50 (1) 50'-55' REC=97%/ RQD=97% (0.25) 50 (0.25) LIMESTONE, light gray, very hard, dry, with intermittent shale lenses Remarks: Boring was advanced to the 35 ft depth using dry drilling technology and groundwater was encountered at the 28 ft depth. Below 35 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

99 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-11 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/4/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 10 (6) 12 (6) 9 (6) 10 (6) Strata Description CLAY, light gray and yellowish brown, moist to wet, soft to stiff, with iron stains and trace calcareous nodules (CL) SAND, yellow, very loose, water bearing, with fine grained sand (SP) CLAY, light gray, moist, soft, slickensided, with iron stains (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 2.5 tsf 20.8 PP = 2.0 tsf 23.4 PP = 2.5 tsf % Passing No. 200 Sieve = PP = 0.5 tsf 15.4 N = 7 bpf % Passing No. 200 Sieve = (0.5) 50 (0.5) LIMESTONE, light gray, hard to very hard, argillaceous, with intermittent shale seams SHALE, gray, soft to hard, moist, slightly calcareous, with intermittent limestone seams 15'-20' REC=100%/ RQD=97% (0.25) 50 (0.25) LIMESTONE, light gray, very hard, dry, with occasional shale lenses 20'-25' REC=70%/ RQD=63% SHALE, gray, medium hard, moist, calcareous (1.5) 50 (1) 25'-30' REC=97%/ RQD=97% (2) 50 (1) 30'-35' REC=88%/ RQD=85% LIMESTONE, light gray, very hard, dry, with intermittent shale lenses (0.25) 50 (0.25) 40 Remarks: Boring was advanced to the 15 ft depth using dry drilling technology and groundwater was encountered at the 7.5 ft depth. Below 15 ft, the boring was advanced to its completion depth of 35 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

100 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-12 Structure North Tarrant Express Station Offset 7.77 LT District Fort Worth Date 3/31/10 Grnd. Elev ft GW Elev ft 517. Elev. (ft) L O G Texas Cone Penetrometer 8 (6) 7 (6) 2 (6) 5 (6) Strata Description FILL, CLAY, brown, moist, soft, with, trace gravel (FILL) FILL, CLAY, dark brown, moist, soft to stiff (FILL) FILL, SANDY CLAY, brown, moist, very soft to soft, trace gravel (FILL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 2.5 tsf % Passing No. 200 Sieve = PP = 4.5+ tsf PP = 4.0 tsf PP = 3.25 tsf 16.6 PP = 4.0 tsf PP = 2.0 tsf PP = 2.0 tsf (6) 12 (6) SAND, clayey, reddish brown, slightly compact (SC) PP = 4.5+ tsf (6) 8 (6) SAND, silty, brown, dry, loose, with trace organics (SM) 13.9 PP = 1.0 tsf PP = 1.0 tsf (6) 16 (6) 2 (6) 3 (6) SAND, tan, dry, slightly compact, with few clay lenses (SP) GRAVEL, tan, wet, slightly compact (GP) CLAY, tan, moist to wet, very soft, with intermittent silty sand lenses and trace organics (CL) 6.3 N = 18 bpf N = 11 bpf SAND, clayey, tan, wet, very loose to loose (SC) 21.6 N = 2 bpf 35 5 (6) 10 (6) SAND, tan, wet, slightly compact (SC-SM) 15.5 N = 18 bpf 40 9 (6) 17 (6) Remarks: Boring was advanced to the 50 ft depth using dry drilling technology and groundwater was encountered at the 25 ft depth. Below 50 ft, the boring was advanced to its completion depth of 80 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

101 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-12 Structure North Tarrant Express Station Offset 7.77 LT District Fort Worth Date 3/31/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SAND, tan, wet, slightly compact (SC-SM) GRAVEL, tan, wet, compact, with trace clay lenses (GP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 14.1 N = 61 bpf Additional Remarks (3.5) 50 (3.25) 50 (1) 50 (0.75) LIMESTONE, moderately weathered, tan, soft, moist, fractured, with intermittent gravel seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams SHALE, gray, hard to very hard, calcareous, with limestone seams 50'-55' REC=97%/ RQD=85% (0.5) 50 (1) LIMESTONE, light gray, hard to very hard, dry, with shale seams SHALE, gray, hard to very hard, dry, calcareous, with intermittent limestone lenses '-60' REC=98%/ RQD=98% (0.5) 50 (0.25) '-65' REC=95%/ RQD=90% SHALE, gray and brown, soft to very hard, moist (2) 50 (2) '-70' REC=93%/ RQD=93% (1) 50 (1.5) 70'-75' REC=97%/ RQD=97% (1.25) 50 (1) 75'-80' REC=97%/ RQD=97% (0.5) 50 (0.25) Remarks: Boring was advanced to the 50 ft depth using dry drilling technology and groundwater was encountered at the 25 ft depth. Below 50 ft, the boring was advanced to its completion depth of 80 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

102 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-15 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/15/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 8 (6) 7 (6) 9 (6) 9 (6) Strata Description FILL, SANDY CLAY, reddish brown, moist, soft, with gravel (FILL) CLAY, reddish brown, moist, soft, with trace gravel (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = 56 PP = 1.0 tsf % Passing No. 200 Sieve = PP = 3.5 tsf PP = 4.0 tsf 13.3 PP = 2.75 tsf PP = 3.0 tsf PP = 2.0 tsf % Passing No. 200 Sieve = (6) 4 (6) PP = 1.5 tsf 17.8 N = 8 bpf 20 6 (6) 6 (6) (6) 25 (6) SAND, tan and light gray, wet, loose to compact (SC-SM) SAND, silty, tan, wet, compact (SM) 20.4 % Passing No. 200 Sieve = 71 PP = 1.0 tsf (5) 50 (6) 50 (0.5) 50 (0.5) GRAVEL, tan, wet, dense (GP-GC) LIMESTONE, tan to gray, hard to very hard, dry SHALE, gray, hard, moist, calcareous, with intermittent limestone seams 21.1 % Passing No. 200 Sieve = (1) 50 (0.5) 35'-40' REC=80%/ RQD=32% (0.5) 50 (0.25) LIMESTONE, light gray, hard to very hard, dry SHALE, gray, very hard, moist 40'-45' REC=98%/ RQD=90% Remarks: Boring was advanced to the 35 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Below 35 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

103 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-15 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/15/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray, very hard, moist Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks SHALE, gray, hard, moist, fissile (1.5) 50 (1.5) 45'-50' REC=95%/ RQD=95% (0.5) 50 (0.5) Remarks: Boring was advanced to the 35 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Below 35 ft, the boring was advanced to its completion depth of 45 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

104 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-16 Structure North Tarrant Express Station Offset RT District Fort Worth Date 4/1/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) 5 L O G Texas Cone Penetrometer 40 (6) 50 (2.5) Strata Description SAND, clayey, reddish brown, moist, slightly compact (SC) GRAVEL, reddish brown to reddish tan, dry, compact to dense, with intermittent clay seams (GP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 4.5+ tsf 5.8 N = 24 bpf 7.3 N = 48 bpf (3.5) 50 (1.5) LIMESTONE, moderately weathered, tan, soft to hard, moist, fractured, with intermittent clay seams N = 50/4in (2) 50 (0.5) LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams (1) 50 (0.75) 20'-25' REC=100%/ RQD=82% (0.5) 50 (0.25) 25'-30' REC=98%/ RQD=63% (1) 50 (0.5) SHALE, gray, hard, moist, with intermittent limestone lenses LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams '-35' REC=98%/ RQD=58% (0.5) 50 (0.25) 35'-40' REC=98%/ RQD=58% (0.5) 50 (0.25) 40'-45' REC=98%/ RQD=88% Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 20 ft, the boring was advanced to its completion depth of 50 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

105 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-16 Structure North Tarrant Express Station Offset RT District Fort Worth Date 4/1/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) 45 L O G Texas Cone Penetrometer 50 (1) 50 (1.5) Strata Description LIMESTONE, light gray, hard to very hard, dry, with interbedded shale seams SHALE, gray to brown, hard, moist, fissile Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks 45'-50' REC=95%/ RQD=95% (1) 50 (1) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 20 ft, the boring was advanced to its completion depth of 50 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

106 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-17 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/5/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) L O G Texas Cone Penetrometer 40 (6) 50 (5.5) 50 (4.5) 50 (4) Strata Description CLAY, sandy, reddish gray, moist, soft, with fine grained sand (CL) SAND, yellow, dry, compact to very dense, with fine to coarse sand and fine angular to subangular gravel (SP) LIMESTONE, tan, soft to hard, dry, weathered, fractured, with interbedded clay seams Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 15.8 PP = 2.75 tsf PP = 2.75 tsf 13.5 PP = 2.75 tsf 15.3 PP = 4.5+ tsf N = 36 bpf Additional Remarks (1) 50 (0.5) LIMESTONE, light gray, hard to very hard, dry, fossiliferous, fractured, with intermittent shale lenses 15'-20' REC=98%/ RQD=50% (4) 50 (3) SHALE, gray, soft, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, very hard, dry, with intermittent shale lenses 20'-25' REC=70%/ RQD=48% (0.25) 50 (0.25) 25'-30' REC=95%/ RQD=55% (0.5) 50 (0.25) 30'-35' REC=90%/ RQD=68% (3) 50 (2) SHALE, brown and gray, soft to very hard, moist, calcareous 35'-40' REC=88%/ RQD=88% (1.75) 50 (1) 40'-45' REC=95%/ RQD=95% Remarks: Boring was advanced to the 15 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 15 ft, the boring was advanced to its completion depth of 60 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

107 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-17 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/5/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, brown and gray, soft to very hard, moist, calcareous Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (1.5) 50 (1) 45'-50' REC=87%/ RQD=83% (1) 50 (1) 50'-55' REC=43%/ RQD=43% (1) 50 (0.5) 55'-60' REC=93%/ RQD=93% (1) 50 (0.75) Remarks: Boring was advanced to the 15 ft depth using dry drilling technology and groundwater was not encountered above that depth. Below 15 ft, the boring was advanced to its completion depth of 60 ft using wet drilling technology. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

108 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-18 Structure North Tarrant Express Station Offset RT District Fort Worth Date 4/1/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 4 (6) 5 (6) Strata Description FILL, gravel, light brown, dry FILL, loose clay, (FILL) brown and tan, moist, soft, with trace calcareous nodules (FILL) SAND, clayey, reddish brown, moist, loose, with trace gravel (SC) GRAVEL, reddish tan, moist to saturated, slightly compact (GP) 50 (1.25) 50 (0.25) SAND, clayey, tan, wet, very dense GRAVEL, (SC) tan, wet, dense, with intermittent clay lenses (GP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 9.4 PP = 2.5 tsf PP = 2.0 tsf PP = 2.0 tsf 21.8 PP = 2.0 tsf PP = 1.0 tsf Additional Remarks PP = 4.5+ tsf 7.9 N = 39 bpf 9.8 N = 57 bpf (3) 50 (1) 50 (1.75) 50 (1) CLAY, tan, moist, very hard, calcareous, LIMESTONE, blocky (CL) moderately weathered, tan, soft to hard LIMESTONE, light gray, hard, dry, with intermittent shale seams N = 50/3in Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

109 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-19 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/18/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 4 (6) 6 (6) 8 (6) 10 (6) 5 (6) 5 (6) Strata Description FILL, SANDY CLAY, reddish brown, moist, soft, with trace gravel (FILL) FILL, SILTY SAND, reddish brown, CLAY, very dark loose gray (FILL) to brown, moist, soft, with trace calcareous nodules (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) 24 PP = 1.5 tsf 17.3 PP = 1.5 tsf Additional Remarks % Passing No. 200 Sieve = PP = 3.0 tsf % Passing No. 200 Sieve = 51 PP = 3.0 tsf 20.7 PP = 0.75 tsf 17.3 PP = 4.0 tsf % Passing No. 200 Sieve = 48 PP = 2.0 tsf PP = 2.0 tsf 14.0 PP = 2.0 tsf (1) 50 (0.75) 50 (1) 50 (0.5) CLAY, gravelly, brown and gray, moist to wet, soft to stiff (CL) LIMESTONE, moderately weathered, tan, hard to very hard, moist CLAY, light brown and gray, hard LIMESTONE, (CH) moderately weathered, tan, hard to very hard, moist, fractured, with interbedded clay seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams % Passing No. 200 Sieve = 60 N = 50/4in. N = 50/5in. 25'-30' REC=97%/ RQD=57% (0.75) 50 (0.25) SHALE, gray and brown, soft to hard, moist, fissile 30'-35' REC=98%/ RQD=95% (1.5) 50 (1.5) '-40' REC=67%/ RQD=67% (1.5) 50 (1.5) 40'-45' REC=95%/ RQD=95% Remarks: Boring was advanced to the 25 ft depth using dry drilling technology and groundwater was encountered at the 8 ft depth. Below 25 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

110 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-19 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/18/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray and brown, soft to hard, moist, fissile Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (2) 50 (2) '-50' REC=93%/ RQD=93% (0.75) 50 (0.75) 50'-55' REC=98%/ RQD=98% (1.5) 50 (0.75) Remarks: Boring was advanced to the 25 ft depth using dry drilling technology and groundwater was encountered at the 8 ft depth. Below 25 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

111 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-20 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/20/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 18 (6) 10 (6) 50 (3.5) 50 (3.5) Strata Description CLAY, sandy, brown, moist, stiff (CL) SAND, silty, tan, dry, loose (SM) GRAVEL, clayey, tan, slightly compact, dry to water bearing (GP-GC) LIMESTONE, tan, soft, moist, weathered, fractured SHALE, light brown and gray, soft, moist, slickensided, with intermittent weathered limestone seams Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = 52 PP = 4.5+ tsf 10.6 % Passing No. 200 Sieve = N = 11 bpf 7.4 N = 48 bpf 10.4 % Passing No. 200 Sieve = 13 N = 50/4in PP = 4.5+ tsf (2) 50 (1) 50 (1) 50 (0.5) LIMESTONE, tan, hard, dry, weathered, fractured LIMESTONE, light gray, hard to very hard, dry, fractured, with interbedded shale lenses SHALE, gray, soft to hard, moist, calcareous, with intermittent limestone seams LIMESTONE, light gray, hard to very hard, dry, with intermittent shale seams 20'-25' REC=97%/ RQD=62% (0.25) 50 (0.25) SHALE, gray and brown, soft to hard, moist, fissile 25'-30' REC=99%/ RQD=93% (1.75) 50 (2) 30'-35' REC=88%/ RQD=88% (1) 50 (1) 35'-40' REC=70%/ RQD=62% (1) 50 (0.75) 40'-45' REC=97%/ RQD=97% Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 8.5 ft depth. Below 20 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

112 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-20 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/20/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray and brown, soft to hard, moist, fissile Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (1) 50 (0.75) 45'-50' REC=78%/ RQD=78% (1) 50 (1) 50'-55' REC=90%/ RQD=90% (1) 50 (1) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 8.5 ft depth. Below 20 ft, the boring was advanced to its completion depth of 55 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

113 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-21 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/13/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 5 (6) 7 (6) Strata Description FILL, SANDY CLAY, dark gray and brown, moist, very stiff, with fine grained sand (FILL) CLAY, sandy, yellow, moist, soft (CL) CLAY, sandy, yellow, moist, soft (CL) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks PP = 2.25 tsf, fine-grained sa % Passing No. 200 Sieve = % Passing No. 200 Sieve = PP = 2.0 tsf 10 5 (6) 8 (6) PP = 1.0 tsf % Passing No. 200 Sieve = (6) 25 (6) SAND, clayey, wet, compact to very dense (SC) PP = 4.5+ tsf 16.9 N = 50/3in (3.5) 50 (0.25) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

114 DRILLING LOG 1 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-22 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/13/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 10 L O G Texas Cone Penetrometer 7 (6) 11 (6) 7 (6) 7 (6) Strata Description CLAY, sandy, reddish brown, moist, soft (CL) SAND, silty, reddish tan, dry, loose (SM) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks % Passing No. 200 Sieve = PP = 4.0 tsf 12.4 PP = 4.0 tsf PP = 3.0 tsf PP = 2.0 tsf PP = 2.0 tsf 11.0 % Passing No. 200 Sieve = N = 8 bpf 2.4 N = 14 bpf (6) 29 (6) SAND, tan, dry, loose to compact (SP) 3.8 N = 30 bpf 20 8 (6) 10 (6) 4.1 N = 6 bpf 25 4 (6) 2 (6) SAND, reddish tan, dry, slightly compact to compact (SP) 3.7 N = 15 bpf (6) 23 (6) N = 14 bpf (6) 33 (6) N = 35 bpf (6) 28 (6) Remarks: Boring was advanced to the 60 ft depth using dry drilling technology and groundwater was encountered at the 35 ft depth. Below 60 ft, the boring was advanced to its completion depth of 75 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

115 DRILLING LOG 2 of 2 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-22 Structure North Tarrant Express Station Offset LT District Fort Worth Date 3/13/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SAND, reddish tan, dry, slightly compact to compact (SP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks 19.9 N = 8 bpf (6) 43 (6) GRAVEL, tan, wet, compact, fine to coarse (GP) (6) 50 (6) CLAY, light brown and gray, moist, hard, slickensided (CH) N = 41 bpf (1.5) 50 (1.5) LIMESTONE, light gray, hard to SHALE, very hard, gray, dry very hard, moist, with intermittent limestone seams (0.5) 50 (0.25) 60'-65' REC=88%/ RQD=50% (1.5) 50 (0.5) LIMESTONE, light gray, hard to very hard, dry, with intermittent shale lenses SHALE, gray, hard to very hard, moist, with intermittent limestone lenses and seams 65'-70' REC=93%/ RQD=75% (0.5) 50 (0.5) 70'-75' REC=90%/ RQD=90% (1) 50 (0.75) 80 Remarks: Boring was advanced to the 60 ft depth using dry drilling technology and groundwater was encountered at the 35 ft depth. Below 60 ft, the boring was advanced to its completion depth of 75 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4.clg

116 DRILLING LOG 1 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-23 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/12/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer 4 (6) 5 (6) 14 (6) 13 (6) 3 (6) 5 (6) 11 (6) 6 (6) Strata Description FILL, CLAYEY SAND, reddish brown, moist, loose, with trace gravel (FILL) SAND, silty, reddish brown, moist to dry, loose (SM) SAND, clayey, reddish brown, moist, loose (SC) SAND, silty, reddish tan, dry, very loose to slightly compact, with intermittent clay lenses and trace gravel (SM) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties Wet MC LL PI Den. (pcf) Additional Remarks 16 % Passing No. 200 Sieve = PP = 2.5 tsf N = 13 bpf PP = 2.5 tsf PP = 2.5 tsf PP = 2.5 tsf PP = 2.5 tsf 11.4 PP = 0.5 tsf (6) 4 (6) GRAVEL, reddish brown, dry, loose, with fine to coarse sand (GP) SAND, reddish tan, dry, loose to slightly compact (SP) 5.3 N = 12 bpf 7.4 N = 9 bpf (6) 12 (6) 30 6 (6) 8 (6) 5.6 N = 6 bpf (6) 30 (6) GRAVEL, tan, moist to wet, slightly compact to compact, with medium to coarse sand (GP-GC) 5.6 N = 66 bpf (6) 15 (6) 10.8 N = 39 bpf Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 30 ft depth. Below 65 ft, the boring was advanced to its completion depth of 95 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4-2.clg

117 DRILLING LOG 2 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-23 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/12/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description GRAVEL, tan, moist to wet, slightly compact to compact, with medium to coarse sand (GP-GC) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (6) 5 (6) SAND, reddish tan, moist, loose, with intermittent silty sand partings (SC) 16.8 N = 38 bpf 6.0 % Passing No. 200 Sieve = (6) 20 (6) GRAVEL, tan, moist, compact, with intermittent clay lenses and sand partings (GP-GC) N = 30 bpf (6) 12 (6) CLAY, sandy, tan, moist, soft, with interbedded sand partings (CL) SAND, tan, moist, slightly compact with fine sub-angular to rounded gravel (SP) CLAY, light brown and gray, moist, stiff, slickensided (CH) 50 (0.25) 50 (0.25) LIMESTONE, light gray, very hard, SHALE, dry gray, soft to very hard, moist N = 10 bpf % Passing No. 200 Sieve = N = 39 bpf (3.5) 50 (1.5) 65'-70' REC=17%/ RQD=17% (2) 50 (1.75) 70'-75' REC=93%/ RQD=93% (2) 50 (1) 75'-80' REC=80%/ RQD=80% (2) 50 (1) 80'-85' REC=92%/ RQD=92% Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 30 ft depth. Below 65 ft, the boring was advanced to its completion depth of 95 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4-2.clg

118 DRILLING LOG 3 of 3 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-23 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/12/10 Grnd. Elev ft GW Elev ft Elev. (ft) L O G Texas Cone Penetrometer Strata Description SHALE, gray, soft to very hard, moist Triaxial Test Lateral Deviator Press. Stress (psi) (psi) MC Properties Wet LL PI Den. (pcf) Additional Remarks (0.5) 50 (0.25) 85'-90' REC=100%/ RQD=95% (0.5) 50 (0.5) 90'-95' REC=95%/ RQD=95% LIMESTONE, gray, hard to very hard, moist, argillaceous, with interbeddded shale lenses (1) 50 (0.5) Remarks: Boring was advanced to the 65 ft depth using dry drilling technology and groundwater was encountered at the 30 ft depth. Below 65 ft, the boring was advanced to its completion depth of 95 ft using wet drilling technology. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4-2.clg

119 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-24 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/13/10 Grnd. Elev ft GW Elev. N/A Elev. (ft) L O G Texas Cone Penetrometer 5 (6) 3 (6) Strata Description CLAY, reddish brown, moist, soft SAND, (CL) reddish brown, dry, loose SAND, (SP) reddish brown, dry, very loose to loose, with intermittent clay lenses (SP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties MC LL PI Wet Den. Additional Remarks (pcf) NP % Passing No. 200 Sieve = 61 % Passing No. 200 Sieve = N = 13 bpf N = 5 bpf 7.6 N = 5 bpf 10.7 N = 6 bpf 10 6 (6) 4 (6) (6) 11 (6) CLAY, sandy, brown, moist, soft (CL) SAND, tan, dry, loose to compact (SP) N = 4 bpf 4.8 N = 12 bpf (6) 34 (6) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was not encountered above that depth. The ground water elevation was not determined during the course of this boring. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4-2.clg

120 DRILLING LOG 1 of 1 WinCore Version 3.1 County Tarrant Highway IH 820 CSJ NTE 4 - CDA Hole B4-25 Structure North Tarrant Express Station Offset RT District Fort Worth Date 3/31/10 Grnd. Elev ft GW Elev ft Elev. (ft) 5 L O G Texas Cone Penetrometer 16 (6) 15 (6) Strata Description FILL, SAND, reddish tan, moist, loose, with fine to medium sand SAND, and fine reddish angular tan, gravel dry, slightly compact, silty (SP) SAND, reddish tan, dry, loose to slightly compact, fine to coarse, with fine angular to sub-rounded gravel (SP) Triaxial Test Lateral Deviator Press. Stress (psi) (psi) Properties MC LL PI Wet Den. Additional Remarks (pcf) % Passing No. 200 Sieve = 25 PP = 0.5 tsf 3.6 N = 25 bpf 5.3 N = 16 bpf 9.7 N = 14 bpf 4.5 N = 20 bpf (6) 12 (6) SAND, tan, dry, slightly compact to compact (SW) 4.9 N = 18 bpf (6) 14 (6) 13.7 N = 11 bpf (6) 21 (6) Remarks: Boring was advanced to the 20 ft depth using dry drilling technology and groundwater was encountered at the 18 ft depth. Any ground water elevation information provided on this boring log is representative of conditions existing on the day and for the specific location where this information was collected. The actual groundwater elevation may fluctuate due to time, climatic conditions, and/or construction activity. Driller: Terra Testing Logger: Fugro Consultants, Inc. Organization: Fugro Consultants, Inc. C:\Documents and Settings\JohnsonA\My Documents\062610\NTE, Segment 4-2.clg

121 Project No APPENDIX - D GENERALIZED SUBSURFACE PROFILES

122 REV DATE BY DESCRIPTION SIMPLIFIED DRAFT COPY B B4-1 B TCP 100/ / / /4 100/ / /2 100/ /0.5 TCP 100/9 100/ / / /1 100/1 100/ / /2 100/2 B4-3 TCP 100/ /12 58/12 60/12 TCP 11/12 22/12 100/ / / / /1 100/ / / / /1.75 B4-4 B4-5 TCP 9/12 9/12 15/12 24/12 17/12 22/12 33/12 34/12 19/12 14/12 71/12 13/12 16/12 10/12 10/12 92/11 100/6 100/ / /2 TCP 15/12 24/12 100/ /12 21/12 18/12 21/12 32/12 28/12 26/12 14/12 32/12 55/12 82/12 84/ /6 100/ / / /0.75 B4-6 B4-7 TCP 13/12 19/12 19/12 22/12 17/12 9/12 8/12 5/12 27/12 100/4 77/ / / / /1 100/1.75 B4-8 TCP 54/12 30/12 72/8 100/ / / / / /0.75 B4-9 TCP 15/12 9/12 100/2 100/ / / /1 100/ / /2 100/2.5 TCP 15/12 14/12 13/12 21/12 19/12 47/12 50/4 100/ / / / /0.5 B4-11 TCP 22/12 19/12 100/1 100/ / /3 100/0.5 B4-12 TCP 15/12 7/12 24/12 13/12 33/12 5/12 15/12 26/12 100/ / / / /4 100/ / /0.75 B4-15 TCP 15/12 18/12 9/12 12/12 42/12 100/11 100/1 100/ / /3 100/ / VERTICAL SCALE.: 1" = 20' Lithology: HORIZONTAL SCALE.: 1" = 1000' NOTE: Profile represents generalized conditions based on test borings and field observations. Formation contacts and other boundaries as shown do not imply exact locations nor that the portrayed formations are necessarily continuous between borings. Initial Groundwater 24-Hour Groundwater Fill, Unclassified Silty Sand Clean sand, well graded Gravel CH, Fat Clay Clayey sand to silty sand Clean sand, poorly graded USCS Poorly-graded Gravel with Clay CL, Lean Clay Clean, poorly graded sand to clayey sand SHALE SC, Clayey Sand LIMESTONE Fugro Consultants, Inc. TPBE Firm Registration No. F-299 SUBSURFACE PROFILE STA TO STA North Tarrant Express, Segment 4 Loop 820, Tarrant County, Texas Source: Drawn By: DF Project No.: Date: June 21, 2010 APPENDIX D-1

123 REV DATE BY DESCRIPTION SIMPLIFIED DRAFT COPY B4-15 TCP 15/12 18/12 9/12 12/12 42/12 100/11 100/1 B4-16 TCP 90/ /5 100/ / / / / / / /2 B4-17 TCP 90/ /8.5 50/5 100/ /7 100/ / /5 100/ / /2 100/ /1.75 B4-18 TCP 9/12 100/ /4 100/2.75 B4-20 TCP 28/12 100/7 100/3 100/ / / /2 100/ / /2 100/2 B4-19 TCP 10/12 18/12 10/12 100/ / /1 100/3 100/3 100/4 100/ /2.25 B4-21 TCP 12/12 13/12 45/12 100/ / / / / VERTICAL SCALE.: 1" = 20' Lithology: HORIZONTAL SCALE.: 1" = 1000' NOTE: Profile represents generalized conditions based on test borings and field observations. Formation contacts and other boundaries as shown do not imply exact locations nor that the portrayed formations are necessarily continuous between borings. Initial Groundwater 24-Hour Groundwater Fill, Unclassified Silty Sand Clean sand, well graded Gravel CH, Fat Clay Clayey sand to silty sand Clean sand, poorly graded USCS Poorly-graded Gravel with Clay CL, Lean Clay Clean, poorly graded sand to clayey sand SHALE SC, Clayey Sand LIMESTONE Fugro Consultants, Inc. TPBE Firm Registration No. F-299 SUBSURFACE PROFILE STA TO STA North Tarrant Express, Segment 4 Loop 820, Tarrant County, Texas Source: Drawn By: DF Project No.: Date: June 21, 2010 APPENDIX D-2

124 REV DATE BY DESCRIPTION SIMPLIFIED DRAFT COPY B4-25 TCP 31/12 25/12 25/12 41/12 B4-24 TCP 8/12 10/12 18/12 64/12 B4-23 TCP 9/12 27/12 8/12 17/12 10/12 25/12 14/12 B4-22 TCP 18/12 14/12 57/12 18/12 6/12 41/ VERTICAL SCALE.: 1" = 20' Lithology: HORIZONTAL SCALE.: 1" = 1000' NOTE: Profile represents generalized conditions based on test borings and field observations. Formation contacts and other boundaries as shown do not imply exact locations nor that the portrayed formations are necessarily continuous between borings. Initial Groundwater 24-Hour Groundwater Fill, Unclassified Silty Sand Clean sand, well graded Gravel CH, Fat Clay Clayey sand to silty sand Clean sand, poorly graded USCS Poorly-graded Gravel with Clay CL, Lean Clay Clean, poorly graded sand to clayey sand SHALE SC, Clayey Sand LIMESTONE SUBSURFACE PROFILE STA TO STA North Tarrant Express, Segment 4 Highway 121, Tarrant County, Texas Fugro Consultants, Inc. TPBE Firm Registration No. F-299 Source: Drawn By: DF Project No.: Date: June 21, 2010 APPENDIX D-3

125 Project No APPENDIX - E SUMMARY OF LABORATORY TEST RESULTS

126 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B B B B B B B B SC B CL B B B B B SC B B B CL B B B B B B B B B CH B B B B B B SC B B B SC B B CL B B B CH B Fugro Consultants, Inc Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) North Tarrent Express-Segment 4 Maximum Size (mm) %<#200 Sieve Classification Dry Density (pcf) Unconfined Strength, (tsf) Sheet 1 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 1

127 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B CL B B CL B CL B B CL B B B B B B B B B B SC B B CL B B B CL B B CL B CL B B B B B B B B B B CL B B CH B B B CL B B Fugro Consultants, Inc Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) North Tarrent Express-Segment 4 Maximum Size (mm) %<#200 Sieve Classification Dry Density (pcf) Unconfined Strength, (tsf) Sheet 2 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 2

128 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B B CL B SC-SM B B B B B B B B B SC B B B B B B B SC B B CL B B B B B B B B CL B B B B B B B B B B Maximum Size (mm) B CH B Fugro Consultants, Inc Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) North Tarrent Express-Segment 4 %<#200 Sieve Classification Dry Density (pcf) Unconfined Strength, (tsf) Sheet 3 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 3

129 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B CL B B B SC B B B B CL B B B B B B B B B B B CL B B CL B B CH B B B B B B B CL B B B B B B B B CL B B Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) Maximum Size (mm) %<#200 Sieve Classification B SC Fugro Consultants, Inc North Tarrent Express-Segment 4 Dry Density (pcf) Unconfined Strength, (tsf) Sheet 4 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 4

130 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B B B CL B B B B SC B B B B B B B B CL B B B B B B B B B B B B CH B CL B B SC B B B B B CL B B CL B B Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) Maximum Size (mm) %<#200 Sieve Classification B SC Dry Density (pcf) Unconfined Strength, (tsf) Sheet 5 of 7 B Fugro Consultants, Inc North Tarrent Express-Segment 4 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 5

131 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B CL B B B B B CL B B B B B B B CL B B CL B B CL B B B CL B B B CL B B B B B B B B B B SP B B B B B B B Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) Maximum Size (mm) %<#200 Sieve B Fugro Consultants, Inc North Tarrent Express-Segment 4 Classification Dry Density (pcf) Unconfined Strength, (tsf) Sheet 6 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 6

132 FUGRO LAB SUMMARY (ADJUSTED COL WIDTHS) GPJ FUGRO DALLAS DATA TEMPLATE.GDT 6/24/10 Borehole Depth (ft.) Water Content (%) B B B B B B B CL B B CL B B NP NP NP B B B B B SC B B B SC B B B B B B Fugro Consultants, Inc Liquid Limit (%) Plastic Limit (%) Plasticity Index (%) North Tarrent Express-Segment 4 Maximum Size (mm) %<#200 Sieve Classification Dry Density (pcf) Unconfined Strength, (tsf) Sheet 7 of 7 Strain at Failure (%) LABORATORY TEST RESULTS SUMMARY Project No PLATE 7

133 Project No APPENDIX - F PARTICLE SIZE DISTRIBUTION REPORTS

134 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-4 B4-4 B4-4 B4-5 B4-5 Specimen Identification B4-4 B4-4 B4-4 B4-5 B4-5 Fugro Consultants, Inc Tested By: Paulo Pereira D Date Tested: 4/22/2010 D60 Classification FAT CLAY with SAND(CH) CLAYEY SAND(SC) CLAYEY SAND(SC) D North Tarrent Express-Segment 4 Checked By: ADJ D Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

135 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-6 B4-6 B4-7 B4-7 B4-7 Specimen Identification B4-6 B4-6 B4-7 B4-7 B4-7 Fugro Consultants, Inc D Tested By: Date Tested: Muhammad Ibrahim4/20/2010 D60 Classification LEAN CLAY with SAND(CL) LEAN CLAY with SAND(CL) FAT CLAY(CH) LEAN CLAY(CL) D North Tarrent Express-Segment 4 Checked By: ADJ D Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

136 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-8 B4-8 B4-9 B4-9 B4-9 Specimen Identification B4-8 B4-8 B4-9 B4-9 B4-9 Fugro Consultants, Inc Tested By: Paulo Pereira D Date Tested: 3/22/2010 D60 Classification CLAYEY SAND(SC) SANDY LEAN CLAY(CL) D North Tarrent Express-Segment 4 Checked By: ADJ D Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

137 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-9 B4-9 B4-10 B4-10 B4-10 Specimen Identification B4-9 B4-9 B4-10 B4-10 B4-10 Fugro Consultants, Inc Tested By: Paulo Pereira D Date Tested: 3/10/2010 D60 Classification SANDY LEAN CLAY(CL) FAT CLAY(CH) D North Tarrent Express-Segment 4 Checked By: ADJ D Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

138 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-10 B4-10 B4-10 B4-10 B4-11 Specimen Identification B4-10 B4-10 B4-10 B4-10 B4-11 Fugro Consultants, Inc Tested By: Paulo Pereira D Date Tested: 3/10/2010 D60 Classification SANDY LEAN CLAY(CL) CLAYEY SAND(SC) LEAN CLAY with SAND(CL) D North Tarrent Express-Segment 4 Checked By: ADJ D10 Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

139 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-11 B4-11 B4-11 B4-11 B4-11 Specimen Identification B4-11 B4-11 B4-11 B4-11 B4-11 Fugro Consultants, Inc Tested By: Paulo Pereira D Date Tested: 3/19/2010 D Classification LEAN CLAY(CL) North Tarrent Express-Segment 4 D Checked By: ADJ D10 Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

140 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-12 B4-12 B4-12 B4-12 B4-15 Specimen Identification B4-12 B4-12 B4-12 B4-12 B4-15 Fugro Consultants, Inc Tested By: Ahmad Aftab D Date Tested: 3/22/2010 D60 Classification LEAN CLAY(CL) FAT CLAY(CH) SANDY LEAN CLAY(CL) SANDY LEAN CLAY(CL) D North Tarrent Express-Segment 4 Checked By: ADJ D10 Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

141 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-15 B4-15 B4-15 B4-15 B4-15 Specimen Identification B4-15 B4-15 B4-15 B4-15 B4-15 Fugro Consultants, Inc D D60 Classification CLAYEY SAND(SC) LEAN CLAY with SAND(CL) North Tarrent Express-Segment 4 Tested By: James Lanza Date Tested: 3/25/2010 D30 Checked By: Brent McNeme D10 Date Checked: 3/25/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

142 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-15 B4-16 B4-17 B4-17 B4-17 Specimen Identification B4-15 B4-16 B4-17 B4-17 B4-17 Fugro Consultants, Inc Tested By: James Lanza D Date Tested: 3/25/2010 D60 Classification CLAYEY SAND(SC) SANDY LEAN CLAY(CL) North Tarrent Express-Segment 4 D Checked By: Brent McNeme D10 Date Checked: 3/25/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

143 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-17 B4-18 B4-18 B4-18 B4-18 Specimen Identification B4-17 B4-18 B4-18 B4-18 B4-18 Fugro Consultants, Inc Tested By: Ahmad Aftab D Date Tested: 4/23/2010 D60 Classification FAT CLAY with SAND(CH) LEAN CLAY with SAND(CL) CLAYEY SAND(SC) North Tarrent Express-Segment 4 D Checked By: ADJ D10 Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

144 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-20 B4-20 B4-20 B4-21 B4-21 Specimen Identification B4-20 B4-20 B4-20 B4-21 B4-21 Fugro Consultants, Inc D Tested By: Date Tested: Muhammad Ibrahim3/23/2010 D60 Classification SANDY LEAN CLAY(CL) SANDY LEAN CLAY(CL) North Tarrent Express-Segment 4 D Checked By: ADJ D10 Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

145 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-21 B4-22 B4-22 B4-22 B4-22 Specimen Identification B4-21 B4-22 B4-22 B4-22 B4-22 Fugro Consultants, Inc Tested By: James Lanza D D60 Classification SANDY LEAN CLAY(CL) SANDY LEAN CLAY(CL) POORLY GRADED SAND(SP) D30 D Date Tested: 3/25/ North Tarrent Express-Segment 4 Checked By: Brent McNeme Date Checked: 3/25/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

146 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-23 B4-23 B4-23 B4-23 B4-23 Specimen Identification B4-23 B4-23 B4-23 B4-23 B4-23 Fugro Consultants, Inc Tested By: James Lanza D Date Tested: 3/25/2010 D Classification North Tarrent Express-Segment 4 D Checked By: Brent McNeme D10 Date Checked: 3/25/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

147 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-21 B4-22 B4-22 B4-22 B4-22 Specimen Identification B4-21 B4-22 B4-22 B4-22 B4-22 Fugro Consultants, Inc Tested By: James Lanza D D60 Classification SANDY LEAN CLAY(CL) SANDY LEAN CLAY(CL) POORLY GRADED SAND(SP) D30 D Date Tested: 3/25/ North Tarrent Express-Segment 4 Checked By: Brent McNeme Date Checked: 3/25/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

148 PERCENT FINER BY WEIGHT U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS /4 1/ / HYDROMETER GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL coarse fine coarse medium SAND fine SILT OR CLAY FUGRO GSA MULTIPLE GPJ DATATEMPLATE GDT 6/25/10 Specimen Identification B4-25 B4-25 B4-25 Specimen Identification B4-25 B4-25 B4-25 Fugro Consultants, Inc Tested By: Ahmad Aftab D Date Tested: 4/23/2010 D Classification North Tarrent Express-Segment 4 D Checked By: ADJ D Date Checked: 6/24/2010 LL PL PI Cc Cu %Gravel %Sand %Silt %Clay GRAIN SIZE DISTRIBUTION Project No

149 Project No APPENDIX - G UNCONFINED COMPRESSION TEST RESULTS

150 80.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-1, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 50.0 q u = psi E t,50 = Failure Strain= 2.26 % 40.0 Strain Rate= 0.23 %/min Water Content = 16.7 % t = pcf 30.0 d = pcf S= % 20.0 e= Diameter= 2.04 inches Height= 4.21 inches 10.0 H/D= 2.07 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.26 % 0.23 %/min Water Content, W = 16.7 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.21 inches H/D = 2.07 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-1, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

151 120.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-1, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 80.0 q u = psi E t,50 = Failure Strain= 2.26 % 60.0 Strain Rate= 0.23 %/min Water Content = 19.7 % t = pcf d = pcf 40.0 S= % e= Diameter= 2.05 inches Height= 4.22 inches 20.0 H/D= 2.06 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.26 % 0.23 %/min Water Content, W = 19.7 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.05 inches Height (H) = 4.22 inches H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-1, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

152 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-1, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.78 % Strain Rate= 0.20 %/min 80.0 Water Content = 15.9 % t = pcf d = pcf 60.0 S= % e= Diameter= 2.00 inches Height= 4.22 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.78 % 0.20 %/min Water Content, W = 15.9 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.00 inches Height (H) = 4.22 inches H/D = 2.11 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-1, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

153 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-2, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, σa (psi) q u = 3, psi E t,50 = Failure Strain= 0.35 % Strain Rate= 0.06 %/min Water Content = 8.7 % γ t = pcf γ d = pcf S= 74.8 % e= Diameter= 2.04 inches Height= 4.22 inches H/D= 2.07 G s = Description: es Axial Strain, ε a (%) Unconfined Strength, σ f = Young's Modulus, E t,50 = Failure Strain,ε f = Strain Rate = 3, psi 0.35 % 0.06 %/min Water Content, W = 8.7 % Unit Weight, γ t = Dry Unit Weight, γ d = pcf pcf Saturation, S = 74.8 % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.22 inches H/D = 2.07 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-2, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

154 80.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-2, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, σa (psi) q u = E t,50 = psi Failure Strain= 6.13 % Strain Rate= 0.24 %/m in Water Content = 8.7 % γ t = pcf γ d = pcf S= 83.7 % e= Diameter= 2.01 inches Height= 4.23 inches H/D= 2.10 G s = D 2.70 Description: es Axial Strain, ε a (%) Unconfined Strength, σ f = Young's Modulus, E t,50 = Failure Strain,ε f = Strain Rate = psi 6.13 % 0.24 %/min Water Content, W = 8.7 % Unit Weight, γ t = Dry Unit Weight, γ d = pcf pcf Saturation, S = 83.7 % Void Ratio, e = Diameter (D) = Height (H) = 2.01 inches 4.23 inches H/D = 2.10 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE WITH SHALE SEAMS Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-2, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

155 80.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-2, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 50.0 q u = psi E t,50 = Failure Strain= 6.13 % 40.0 Strain Rate= 0.24 %/min Water Content = 8.7 % t = pcf 30.0 d = pcf S= 83.7 % 20.0 e= Diameter= 2.01 inches Height= 4.23 inches 10.0 H/D= 2.10 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 6.13 % 0.24 %/min Water Content, W = 8.7 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 83.7 % Void Ratio, e = Diameter (D) = Height (H) = 2.01 inches 4.23 inches H/D = 2.10 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE WITH SHALE SEAMS Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-2, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

156 160.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-2, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 3.13 % 80.0 Strain Rate= 0.23 %/min Water Content = 15.1 % t = pcf 60.0 d = pcf S= % 40.0 e= Diameter= 2.06 inches Height= 4.24 inches 20.0 H/D= 2.05 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 3.13 % 0.23 %/min Water Content, W = 15.1 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.06 inches Height (H) = 4.24 inches H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-2, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

157 250.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-2, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.89 % Strain Rate= 0.22 %/min Water Content = 14.8 % t = pcf d = pcf S= 92.6 % e= Diameter= 1.96 inches 50.0 Height= 4.23 inches H/D= 2.16 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.89 % 0.22 %/min Water Content, W = 14.8 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 92.6 % Void Ratio, e = Diameter (D) = 1.96 inches Height (H) = 4.23 inches H/D = 2.16 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-2, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

158 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-4, Depth: ft. North Tarrant Express - Segment 4 (MDP) Fort Worth, Texas Compressive Stress, a (psi) q u = 5, psi E t,50 = Failure Strain= 0.36 % Strain Rate= 0.05 %/min Water Content = t = pcf d = S= e= Diameter= 2.04 inches Height= 4.21 inches H/D= 2.07 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = Water Content, W = Unit Weight, t = Dry Unit Weight, d = Saturation, S = 5, psi 0.36 % 0.05 %/min pcf Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.21 inches H/D = 2.07 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-4, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

159 120.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-4, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 80.0 q u = psi E t,50 = Failure Strain= 2.04 % 60.0 Strain Rate= 0.22 %/min Water Content = 14.3 % t = pcf d = pcf 40.0 S= % e= Diameter= 2.07 inches Height= 4.21 inches 20.0 H/D= 2.03 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.04 % 0.22 %/min Water Content, W = 14.3 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.07 inches Height (H) = 4.21 inches H/D = 2.03 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-4, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

160 160.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-4, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.94 % 80.0 Strain Rate= 0.18 %/min Water Content = 16.5 % t = pcf 60.0 d = pcf S= % 40.0 e= Diameter= 2.06 inches Height= 4.20 inches 20.0 H/D= 2.04 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.94 % 0.18 %/min Water Content, W = 16.5 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.06 inches Height (H) = 4.20 inches H/D = 2.04 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-4, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

161 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: 80.0 B4-5, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 2.58 % Strain Rate= 0.24 %/min Water Content = 18.7 % t = pcf d = pcf S= % e= Diameter= 1.97 inches Height= 4.21 inches H/D= 2.14 G s = 2.70 Description: es Axial 1.5 Strain, a 2.0 (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.58 % 0.24 %/min Water Content, W = 18.7 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 1.97 inches Height (H) = 4.21 inches H/D = 2.14 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-5, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

162 120.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-5, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 80.0 q u = psi E t,50 = Failure Strain= 1.41 % 60.0 Strain Rate= 0.22 %/min Water Content = 16.3 % t = pcf d = pcf 40.0 S= % e= Diameter= 2.04 inches Height= 4.20 inches 20.0 H/D= 2.06 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.41 % 0.22 %/min Water Content, W = 16.3 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.20 inches H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-5, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

163 70.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-5, Depth: ft. North Tarrant Express - Segment 4 (MDP) Fort 60.0 Worth, Texas Compressive Stress, a (psi) 50.0 q u = psi E t,50 = 40.0 Failure Strain= 2.06 % Strain Rate= 0.23 %/min Water Content = 2.0 % 30.0 t = pcf d = pcf S= 24.0 % 20.0 e= Diameter= 2.06 inches Height= 4.23 inches 10.0 H/D= 2.05 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.06 % 0.23 %/min Water Content, W = 2.0 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 24.0 % Void Ratio, e = Diameter (D) = 2.06 inches Height (H) = 4.23 inches H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-5, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

164 120.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-6, Depth: ' ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 80.0 q u = psi E t,50 = Failure Strain= 2.22 % 60.0 Strain Rate= 0.23 %/min Water Content = 18.4 % t = pcf d = pcf 40.0 S= % e= Diameter= 1.88 inches Height= 4.22 inches 20.0 H/D= 2.25 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.22 % 0.23 %/min Water Content, W = 18.4 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 1.88 inches Height (H) = 4.22 inches H/D = 2.25 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-6, Depth: ' ft. Project Number: Date: Reviewed By: /18/10 ADJ

165 90.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-6, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 60.0 q u = psi 50.0 E t,50 = Failure Strain= 4.50 % Strain Rate= 0.24 %/min 40.0 Water Content = 4.0 % t = pcf d = pcf 30.0 S= 41.7 % e= Diameter= 2.11 inches Height= 4.25 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 4.50 % 0.24 %/min Water Content, W = 4.0 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 41.7 % Void Ratio, e = Diameter (D) = 2.11 inches Height (H) = 4.25 inches H/D = 2.02 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-6, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

166 250.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-6, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.46 % Strain Rate= 0.21 %/min Water Content = 9.5 % t = pcf d = pcf S= 86.6 % e= Diameter= 2.03 inches 50.0 Height= 4.23 inches H/D= 2.09 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.46 % 0.21 %/min Water Content, W = 9.5 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 86.6 % Void Ratio, e = Diameter (D) = 2.03 inches Height (H) = 4.23 inches H/D = 2.09 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-6, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

167 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-7, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = 4, psi E t,50 = Failure Strain= 0.33 % Strain Rate= 0.05 %/min Water Content = 6.0 % t = pcf d = pcf S= % e= Diameter= 2.04 inches Height= 4.20 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = 4, psi 0.33 % 0.05 %/min Water Content, W = 6.0 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.20 inches H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-7, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

168 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-7, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 2.65 % Strain Rate= 0.23 %/min 80.0 Water Content = 15.3 % t = pcf d = pcf 60.0 S= % e= Diameter= 2.07 inches Height= 4.19 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.65 % 0.23 %/min Water Content, W = 15.3 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.07 inches Height (H) = 4.19 inches H/D = 2.03 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-7, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

169 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-7, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 5.18 % Strain Rate= 0.24 %/min 80.0 Water Content = 6.8 % t = pcf d = pcf 60.0 S= 69.6 % e= Diameter= 2.02 inches Height= 4.22 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 5.18 % 0.24 %/min Water Content, W = 6.8 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 69.6 % Void Ratio, e = Diameter (D) = 2.02 inches Height (H) = 4.22 inches H/D = 2.09 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-7, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

170 250.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-7, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 3.23 % Strain Rate= 0.23 %/min Water Content = 14.9 % t = pcf d = pcf S= % e= Diameter= 2.04 inches 50.0 Height= 4.22 inches H/D= 2.07 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 3.23 % 0.23 %/min Water Content, W = 14.9 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.22 inches H/D = 2.07 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-7, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

171 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-12, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = 3, psi E t,50 = Failure Strain= 0.70 % Strain Rate= 0.10 %/min Water Content = 6.4 % t = pcf d = pcf S= % e= Diameter= 2.05 inches Height= 4.15 inches H/D= 2.02 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = 3, psi 0.70 % 0.10 %/min Water Content, W = 6.4 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.05 inches Height (H) = 4.15 inches H/D = 2.02 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-12, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

172 Report No UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-12, Depth: ft. North Tarrant Express - Segment 4 (MDP) Fort Worth, Texas Compressive Stress, a (psi) q u = psi E t,50 = 80.0 Failure Strain= 3.20 % Strain Rate= 0.24 %/min Water Content = 12.0 % 60.0 t = pcf d = pcf S= 93.3 % 40.0 e= Diameter= 2.09 inches Height= 4.19 inches 20.0 H/D= 2.00 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 3.20 % 0.24 %/min Water Content, W = 12.0 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 93.3 % Void Ratio, e = Diameter (D) = 2.09 inches Height (H) = 4.19 inches H/D = 2.00 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-12, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

173 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-12, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.61 % Strain Rate= 0.21 %/min 80.0 Water Content = 7.8 % t = pcf d = pcf 60.0 S= 65.3 % e= Diameter= 1.98 inches Height= 4.21 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.61 % 0.21 %/min Water Content, W = 7.8 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 65.3 % Void Ratio, e = Diameter (D) = 1.98 inches Height (H) = 4.21 inches H/D = 2.12 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-12, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

174 Report No UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-12, Depth: ft. North Tarrant Express - Segment 4 (MDP) Fort Worth, Texas Compressive Stress, a (psi) q u = psi E t,50 = 80.0 Failure Strain= 3.80 % Strain Rate= 0.24 %/min Water Content = 16.7 % 60.0 t = pcf d = pcf S= 90.7 % 40.0 e= Diameter= 2.14 inches Height= 4.17 inches 20.0 H/D= 1.95 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 3.80 % 0.24 %/min Water Content, W = 16.7 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 90.7 % Void Ratio, e = Diameter (D) = 2.14 inches Height (H) = 4.17 inches H/D = 1.95 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-12, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

175 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-16, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 2.11 % Strain Rate= 0.22 %/min 80.0 Water Content = 6.2 % t = pcf d = pcf 60.0 S= 94.5 % e= Diameter= 2.04 inches Height= 4.21 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.11 % 0.22 %/min Water Content, W = 6.2 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 94.5 % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.21 inches H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-16, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

176 90.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-16, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 60.0 q u = psi 50.0 E t,50 = Failure Strain= 2.01 % Strain Rate= 0.23 %/min 40.0 Water Content = 15.1 % t = pcf d = pcf 30.0 S= % e= Diameter= 2.05 inches Height= 4.24 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.01 % 0.23 %/min Water Content, W = 15.1 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.05 inches Height (H) = 4.24 inches H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-16, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

177 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-16, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.70 % Strain Rate= 0.19 %/min Water Content = 7.0 % t = pcf d = pcf S= 91.5 % e= Diameter= 2.03 inches Height= 4.20 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.70 % 0.19 %/min Water Content, W = 7.0 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 91.5 % Void Ratio, e = Diameter (D) = 2.03 inches Height (H) = 4.20 inches H/D = 2.07 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-16, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

178 180.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-16, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 5.94 % Strain Rate= 0.24 %/min 80.0 Water Content = 6.9 % t = pcf d = pcf 60.0 S= 76.7 % e= Diameter= 2.06 inches Height= 4.23 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 5.94 % 0.24 %/min Water Content, W = 6.9 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 76.7 % Void Ratio, e = Diameter (D) = 2.06 inches Height (H) = 4.23 inches H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: Location: Sample Identification: North Tarrant Express - Segment 4 (MDP) Boring: B4-16, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

179 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-19, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = 2, psi E t,50 = Failure Strain= 0.53 % Strain Rate= 0.09 %/min Water Content = 5.9 % t = pcf d = pcf S= 91.1 % e= Diameter= 2.04 inches Height= 4.18 inches H/D= 2.05 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = 2, psi 0.53 % 0.09 %/min Water Content, W = 5.9 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = 91.1 % Void Ratio, e = Diameter (D) = 2.04 inches Height (H) = 4.18 inches H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : LIMESTONE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-19, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

180 90.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-19, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) 60.0 q u = psi 50.0 E t,50 = Failure Strain= 2.15 % Strain Rate= 0.23 %/min 40.0 Water Content = 17.1 % t = pcf d = pcf 30.0 S= % e= Diameter= 2.07 inches Height= 4.25 inches H/D= G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 2.15 % 0.23 %/min Water Content, W = 17.1 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.07 inches Height (H) = 4.25 inches H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-19, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

181 160.0 UNCONFINED COMPRESSION TEST, ASTM - D 7012, Method C Boring: B4-19, Depth: ft. North Tarrant Express - Segment 4 (MDP) Compressive Stress, a (psi) q u = psi E t,50 = Failure Strain= 1.64 % 80.0 Strain Rate= 0.21 %/min Water Content = 19.1 % t = pcf 60.0 d = pcf S= % 40.0 e= Diameter= 2.03 inches Height= 4.26 inches 20.0 H/D= 2.10 G s = 2.70 Description: es Axial Strain, a (%) Unconfined Strength, f = Young's Modulus, E t,50 = Failure Strain, f = Strain Rate = psi 1.64 % 0.21 %/min Water Content, W = 19.1 % Unit Weight, t = Dry Unit Weight, d = pcf pcf Saturation, S = % Void Ratio, e = Diameter (D) = 2.03 inches Height (H) = 4.26 inches H/D = 2.10 Assumed Sp. Gravity, G s = 2.70 Description : SHALE Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: Boring: B4-19, Depth: ft. Project Number: Date: Reviewed By: /18/10 ADJ

182 Project No APPENDIX - H UNCONSOLIDATED UNDRAINED COMPRESSION TEST RESULTS

183 UNCONSOLIDATED - UNDRAINED TRIAXIAL COMPRESSION TEST - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= % Strain Rate= 1.00 %/min Water Content = 15.4 % γ t = pcf γ d = pcf S= 91.9 % e= Diameter= 2.74 inch Height= 5.51 inch H/D= 2.01 G s = 2.70 Description: Description : FILL Confinement = 22.0 psi Axial Strain, ε a (%) UU Comp. Strength, σ f = Young's Modulus, E t,50 = psi Failure Strain, ε f = % Strain Rate, ε r = 1.00 %/min Water Content, W = 15.4 % Unit Weight, γ t = Dry Unit Weight, γ d = pcf pcf Saturation, S = 91.9 % Confinement Stress, σ 3 = 22.0 psi Void Ratio, e = Diameter (D) = 2.74 inch Height (H) = 5.51 inch H/D = 2.01 Assumed Sp. Gravity, G s = 2.70 Description : FILL Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: B4-5, ft. Project Number: Date: Reviewed By: /24/10 BRENT

184 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = 6.11 psi E t,50 = Failure Strain= 3.65 % Strain Rate= 0.94 %/min Water Content = 24.4 % γ t = pcf γ d = pcf S= 97.2 % e= Diameter= 2.76 inch Height= 5.64 inch H/D= 2.05 G s = 2.70 Description: Description : LEAN CLAY Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = 6.11 psi Young's Modulus, E t,50 = Failure Strain, ε f = 3.65 % Strain Rate, ε r = 0.94 %/min Water Content, W = 24.4 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 97.2 % Void Ratio, e = Diameter (D) = 2.76 inch Height (H) = 5.64 inch H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : LEAN CLAY Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 BRENT

185 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= % Strain Rate= 1.01 %/min Water Content = 22.0 % γ t = pcf γ d = pcf S= 90.5 % e= Diameter= 2.77 inch Height= 5.59 inch H/D= 2.02 G s = 2.70 Description: Description : LEAN CLAY WITH SAND (CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = % Strain Rate, ε r = 1.01 %/min Water Content, W = 22.0 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 90.5 % Void Ratio, e = Diameter (D) = Height (H) = 2.77 inch 5.59 inch H/D = 2.02 Assumed Sp. Gravity, G s = 2.70 Description : LEAN CLAY WITH SAND (CL) Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 BRENT

186 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= % Strain Rate= 1.02 %/min Water Content = 17.2 % γ t = pcf γ d = pcf S= 92.2 % e= Diameter= 2.62 inch Height= 5.62 inch H/D= 2.15 G s = 2.70 Description: Description : FAT CLAY(CH) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = % Strain Rate, ε r = 1.02 %/min Water Content, W = 17.2 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 92.2 % Void Ratio, e = Diameter (D) = 2.62 inch Height (H) = 5.62 inch H/D = 2.15 Assumed Sp. Gravity, G s = 2.70 Description : FAT CLAY(CH) Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: 4-5 ft Project Number: Date: Reviewed By: /24/10 ADJ

187 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 7.99 % Strain Rate= 0.88 %/min Water Content = 18.2 % γ t = pcf γ d = pcf S= 64.1 % e= Diameter= 2.73 inch Height= 6.74 inch H/D= 2.47 G s = 2.70 Description: Description : FILL Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 7.99 % Strain Rate, ε r = 0.88 %/min Water Content, W = 18.2 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 64.1 % Void Ratio, e = Diameter (D) = 2.73 inch Height (H) = 6.74 inch H/D = 2.47 Assumed Sp. Gravity, G s = 2.70 Description : FILL Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 ADJ

188 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 5.83 % Strain Rate= 1.63 %/min Water Content = 18.5 % γ t = pcf γ d = pcf S= 85.6 % e= Diameter= 2.00 inch Height= 3.74 inch H/D= 1.87 G s = 2.70 Description: Description : FILL Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 5.83 % Strain Rate, ε r = 1.63 %/min Water Content, W = 18.5 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 85.6 % Void Ratio, e = Diameter (D) = 2.00 inch Height (H) = 3.74 inch H/D = 1.87 Assumed Sp. Gravity, G s = 2.70 Description : FILL Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 ADJ

189 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 6.60 % Strain Rate= 1.15 %/min Water Content = 17.0 % γ t = pcf γ d = pcf S= 83.2 % e= Diameter= 2.75 inch Height= 5.65 inch H/D= 2.05 G s = 2.70 Description: Description : LEAN CLAY(CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 6.60 % Strain Rate, ε r = 1.15 %/min Water Content, W = 17.0 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 83.2 % Void Ratio, e = Diameter (D) = 2.75 inch Height (H) = 5.65 inch H/D = 2.05 Assumed Sp. Gravity, G s = 2.70 Description : LEAN CLAY(CL) Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 ADJ

190 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 5.96 % Strain Rate= 0.95 %/min Water Content = 13.7 % γ t = pcf γ d = pcf S= 88.6 % e= Diameter= 2.78 inch Height= 5.61 inch H/D= 2.02 G s = 2.70 Description: Description : FILL Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 5.96 % Strain Rate, ε r = 0.95 %/min Water Content, W = 13.7 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 88.6 % Void Ratio, e = Diameter (D) = 2.78 inch Height (H) = 5.61 inch H/D = 2.02 Assumed Sp. Gravity, G s = 2.70 Description : FILL Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 BRENT

191 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 8.49 % Strain Rate= 1.01 %/min Water Content = 14.8 % γ t = pcf γ d = pcf S= 95.9 % e= Diameter= 2.71 inch Height= 5.90 inch H/D= 2.17 G s = 2.70 Description: Description : SANDY LEAN CLAY (CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 8.49 % Strain Rate, ε r = 1.01 %/min Water Content, W = 14.8 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 95.9 % Void Ratio, e = Diameter (D) = Height (H) = 2.71 inch 5.90 inch H/D = 2.17 Assumed Sp. Gravity, G s = 2.70 Description : SANDY LEAN CLAY (CL) Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 ADJ

192 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= % Strain Rate= 0.94 %/min Water Content = 19.3 % γ t = pcf γ d = pcf S= 82.2 % e= Diameter= 2.67 inch Height= 5.70 inch H/D= 2.13 G s = 2.70 Description: Description : FILL Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = % Strain Rate, ε r = 0.94 %/min Water Content, W = 19.3 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 82.2 % Void Ratio, e = Diameter (D) = 2.67 inch Height (H) = 5.70 inch H/D = 2.13 Assumed Sp. Gravity, G s = 2.70 Description : FILL Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: 5-6 ft Project Number: Date: Reviewed By: /24/10 BRENT

193 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 6.25 % Strain Rate= 0.98 %/min Water Content = 15.3 % γ t = pcf γ d = pcf S= 87.9 % e= Diameter= 2.75 inch Height= 5.66 inch H/D= 2.06 G s = 2.70 Description: Description : SANDY LEAN CLAY (CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 6.25 % Strain Rate, ε r = 0.98 %/min Water Content, W = 15.3 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 87.9 % Void Ratio, e = Diameter (D) = Height (H) = 2.75 inch 5.66 inch H/D = 2.06 Assumed Sp. Gravity, G s = 2.70 Description : SANDY LEAN CLAY (CL) Project Name: North Tarrant Express - Segment 4 ( MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 BRENT

194 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= 7.63 % Strain Rate= 1.07 %/min Water Content = 19.9 % γ t = pcf γ d = pcf S= 92.9 % e= Diameter= 2.69 inch Height= 5.81 inch H/D= 2.16 G s = 2.70 Description: Description : SANDY LEAN CLAY(CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = 7.63 % Strain Rate, ε r = 1.07 %/min Water Content, W = 19.9 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 92.9 % Void Ratio, e = Diameter (D) = Height (H) = 2.69 inch 5.81 inch H/D = 2.16 Assumed Sp. Gravity, G s = 2.70 Description : SANDY LEAN CLAY(CL) Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: 8-9 ft Project Number: Date: Reviewed By: /24/10 ADJ

195 UNCONFINED COMPRESSIVE STRENGTH OF COHESIVE SOIL - ASTM D Compressive Stress, σa (psi) q u = psi E t,50 = Failure Strain= % Strain Rate= 1.03 %/min Water Content = 12.5 % γ t = pcf γ d = pcf S= 79.9 % e= Diameter= 2.67 inch Height= 5.43 inch H/D= 2.04 G s = 2.70 Description: Description : SANDY LEAN CLAY(CL) Confinement = 22.0 psi Axial Strain, ε a (%) Unconfined Comp. Strength, σ f = psi Young's Modulus, E t,50 = Failure Strain, ε f = % Strain Rate, ε r = 1.03 %/min Water Content, W = 12.5 % Unit Weight, γ t = pcf Dry Unit Weight, γ d = pcf Saturation, S = 79.9 % Void Ratio, e = Diameter (D) = Height (H) = 2.67 inch 5.43 inch H/D = 2.04 Assumed Sp. Gravity, G s = 2.70 Description : SANDY LEAN CLAY(CL) Project Name: North Tarrant Express - Segment 4 (MDP) Location: Sample Identification: ft Project Number: Date: Reviewed By: /24/10 ADJ

Project: ITHACA-TOMPKINS REGIONAL AIRPORT EXPANSION Project Location: ITHACA, NY Project Number: 218-34 Key to Soil Symbols and Terms TERMS DESCRIBING CONSISTENCY OR CONDITION COARSE-GRAINED SOILS (major

More information

Photo 1 - Southerly view across 2700 parking lot toward existing building. Multi-residential building borders western side of property in upper right of view. Photo 2 - Southerly view across 2750 parking

More information

SOIL CLASSIFICATION CHART COARSE-GRAINED SOILS MORE THAN 50% RETAINED ON NO.200 SIEVE FINE-GRAINED SOILS 50% OR MORE PASSES THE NO.200 SIEVE PRIMARY DIVISIONS GRAVELS MORE THAN 50% OF COARSE FRACTION RETAINED

More information

TP-1 N61E 0 DARK BROWN SANDY SILT (ML) stiff, wet with roots (Disturbed Surficial Soil) DEPTH (FEET) 5 REDDISH BROWN SANDSTONE intensely fractured, weak to friable, deeply weathered, tight (Franciscan

More information

DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS

DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS DATA REPORT GEOTECHNICAL INVESTIGATION GALVESTON CRUISE TERMINAL 2 GALVESTON, TEXAS SUBMITTED TO PORT OF GALVESTON 123 ROSENBERG AVENUE, 8TH FLOOR GALVESTON, TEXAS 77553 BY HVJ ASSOCIATES, INC. HOUSTON,

More information

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS.

B-1 BORE LOCATION PLAN. EXHIBIT Drawn By: 115G BROOKS VETERINARY CLINIC CITY BASE LANDING AND GOLIAD ROAD SAN ANTONIO, TEXAS. N B-1 SYMBOLS: Exploratory Boring Location Project Mngr: BORE LOCATION PLAN Project No. GK EXHIBIT Drawn By: 115G1063.02 GK Scale: Checked By: 1045 Central Parkway North, Suite 103 San Antonio, Texas 78232

More information

APPENDIX A. Borehole Logs Explanation of Terms and Symbols

APPENDIX A. Borehole Logs Explanation of Terms and Symbols APPENDIX A Borehole Logs Explanation of Terms and Symbols Page 153 of 168 EXPLANATION OF TERMS AND SYMBOLS The terms and symbols used on the borehole logs to summarize the results of field investigation

More information

APPENDIX C HYDROGEOLOGIC INVESTIGATION

APPENDIX C HYDROGEOLOGIC INVESTIGATION Figure B-5.7 Figure B-5.8 Preliminary Geotechnical and Environmental Report Appendix C Hydrogeologic Investigation APPENDIX C HYDROGEOLOGIC INVESTIGATION December 21, 2011 WESTSIDE SUBWAY EXTENSION PROJECT

More information

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF

Depth (ft) USCS Soil Description TOPSOIL & FOREST DUFF Test Pit No. TP-6 Location: Latitude 47.543003, Longitude -121.980441 Approximate Ground Surface Elevation: 1,132 feet Depth (ft) USCS Soil Description 0 1.5 1.5 5.0 SM 5.0 8.0 SM Loose to medium dense,

More information

Field Exploration. March 31, J-U-B ENGINEERS, Inc. 115 Northstar Avenue Twin Falls, Idaho Attn: Mr. Tracy Ahrens, P. E. E:

Field Exploration. March 31, J-U-B ENGINEERS, Inc. 115 Northstar Avenue Twin Falls, Idaho Attn: Mr. Tracy Ahrens, P. E. E: March 31, 201 11 Northstar Avenue 83301 Attn: Mr. Tracy Ahrens, P. E. E: taa@jub.com Re: Geotechnical Data Report Preliminary Phase 1 Field Exploration Revision No. 1 Proposed Rapid Infiltration Basin

More information

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx

Civil Engineering, Surveying and Environmental Consulting WASP0059.ltr.JLS.Mich Ave Bridge Geotech.docx 2365 Haggerty Road South * Canton, Michigan 48188 P: 734-397-3100 * F: 734-397-3131 * www.manniksmithgroup.com August 29, 2012 Mr. Richard Kent Washtenaw County Parks and Recreation Commission 2330 Platt

More information

Appendix G GEOLOGICAL INVESTIGATION

Appendix G GEOLOGICAL INVESTIGATION Appendix G GEOLOGICAL INVESTIGATION JOB NUMBER: 3268.001 DATE: 10-14-13 BY: CC SITE 0 2000 1"=2000' VICINITY MAP CARGILL PARCEL HICKORY STREET AND ENTERPRISE DRIVE NEWARK, CALIFORNIA FOR

More information

Brazos River Authority

Brazos River Authority Brazos River Authority QUALITY CONSERVATION SERVICE December 28, 2018 BRAZOS RIVER AUTHORITY LAKE GRANBURY PARK ROADS REHABILITATION RFB #19-11-97 ADDENDUM NO. 3 Bidders on this project are hereby notified

More information

APPENDIX C. Borehole Data

APPENDIX C. Borehole Data APPENDIX C Borehole Data MAJOR DIVISIONS SOIL CLASSIFICATION CHART SYMBOLS GRAPH LETTER TYPICAL DESCRIPTIONS ADDITIONAL MATERIAL

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Bridge B Bridge Crossing: South 257 th West Avenue Creek County, Oklahoma June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Tulsa,

More information

GEOTECHNICAL INVESTIGATION GEOTECHNICAL INVESTIGATION FLAT CREEK WASTEWATER INTERCEPTOR GARLIC CREEK FORCE MAIN WACO, TEXAS BUDA, TEXAS

GEOTECHNICAL INVESTIGATION GEOTECHNICAL INVESTIGATION FLAT CREEK WASTEWATER INTERCEPTOR GARLIC CREEK FORCE MAIN WACO, TEXAS BUDA, TEXAS GEOTECHNICAL INVESTIGATION GEOTECHNICAL INVESTIGATION FLAT CREEK WASTEWATER INTERCEPTOR GARLIC CREEK FORCE MAIN WACO, TEXAS BUDA, TEXAS G. E. WALKER & ASSOCIATES, L.L.C. LOCKWOOD, ANDREWS & NEWNAM, INC.

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION 42-INCH FORCE MAIN REPLACEMENT CHIQUITA BOULEVARD S AND SW 34 TH STREET CAPE CORAL, LEE COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials

More information

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON

ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON F I N A L A D D E N D U M 1 R E P O R T ADDENDUM 1 FISHER SLOUGH RESTORATION PROJECT SKAGIT COUNTY, WASHINGTON REPORT OF GEOTECHNICAL INVESTIGATION URS JOB NO. 3376186 Prepared for Tetra Tech Inc. 142

More information

DATE: 5/17/2012. LOGGED BY: Geoff Richards. COMPANY: Tetra Tech EM, Inc. DRILL FOREMAN: Walter

DATE: 5/17/2012. LOGGED BY: Geoff Richards. COMPANY: Tetra Tech EM, Inc. DRILL FOREMAN: Walter ATTACHMENT 2 Page 1 of 1 B1 0 1 2 FILL, Dry; brownish red; clayey silt and gravel; ~30% gravel size fragments of dark grey microcrystalline (aphanetic), extrusive, igneous, rock 3 B1-4a 1100 B1-4b-duplicate

More information

APPENDIX A GEOTECHNICAL REPORT

APPENDIX A GEOTECHNICAL REPORT The City of Winnipeg Bid Opportunity No. 529-2017 Template Version: C420170317 - RW APPENDIX A GEOTECHNICAL REPORT Quality Engineering Valued Relationships KGS Group 2017 Industrial Street Rehabilitation

More information

Jim Christal Rd B2 B1 B3

Jim Christal Rd B2 B1 B3 Jim Christal Rd B1 B2 B3 KEY O YMBOL AND ERM LIHOLOGIC YMBOL Asphalt ARIFICIAL Aggregate Base Concrete Fill CH: High Plasticity Clay CL: Low Plasticity Clay Consistency Very oft oft Medium tiff tiff Very

More information

UNIT DESCRIPTIONS: Artificial Fill, Undocumented (Afu): Locally derived sandy silt and silty sand, locally with clay and varying amounts of gravel and man-made debris. Abundant concrete rubble, in places

More information

New WW Hastings Hospital Geotechnical Investigation RFP Addendum #1

New WW Hastings Hospital Geotechnical Investigation RFP Addendum #1 88 E. Marshall Street, Suite 0 Tulsa, OK 76 98 8 9 Phone 98 8 798 FAX DATE: April 9, 0 ADDENDUM NO.: PROJECT: New WW Hastings Hospital BID PACKAGE NO: Geotechnical Investigation RFP SUBMITTED BY: CNCR

More information

LEGEND ODOT CLASS A-3. A-3a. A-4a. A-6a. A-6b TOTAL VISUAL VISUAL VISUAL BORING LOCATION - PLAN VIEW

LEGEND ODOT CLASS A-3. A-3a. A-4a. A-6a. A-6b TOTAL VISUAL VISUAL VISUAL BORING LOCATION - PLAN VIEW PROJECT THE PROJECT CONSISTS IN PART OF CONSTRUCTING A SINGLE-SPAN BRIDGE ON RELOCATED SHUMWAY HOOW ROAD OVER THE CSXT RAILROAD. THE STRUCTURE AS ANNED, IS A SINGLE-SPAN STRUCTURE WITH MSE WAS AT THE ABUTMENTS.

More information

December 5, Junction Gateway, LLC 7551 W. Sunset Boulevard #203 Los Angeles, CA Mr. James Frost P: Dear Mr.

December 5, Junction Gateway, LLC 7551 W. Sunset Boulevard #203 Los Angeles, CA Mr. James Frost P: Dear Mr. December 5, 2014 Junction Gateway, LLC 7551 W. Sunset Boulevard #203 90046 Attn: Re: Mr. James Frost P: 323.883.1800 Geotechnical Update Letter Sunset & Effie Mixed Use Development 4301 to 4311 Sunset

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report Emergency Bridge Package 6 Richland County, South Carolina May 12, 2016 SCDOT Project ID.: P029942, P029943, P029944 Terracon Project No. 73100L (Rev. 1) Prepared for: South Carolina

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report Downtown Greenville Future Conveyance Study December 1, 2015 Terracon Project No. 86155032 Prepared for: Prepared by: Terracon Consultants, Inc. December 1, 2015 561 Mauldin Road

More information

PLATE 6 FEB G r o v e l a n d F l o o d w a l l - B o r e h o l e M a p. Legend. Groveland Floodwall Boreholes. Contour Lines.

PLATE 6 FEB G r o v e l a n d F l o o d w a l l - B o r e h o l e M a p. Legend. Groveland Floodwall Boreholes. Contour Lines. 611 6 Defau FALS conto Conto DPLV lt Eurs20 01_to 3po Defau FALS conto Conto DPLV lt Eurs20 01_to 4po 612 Conto DPLV conto Defau FALS 01_to urs20 Elt po 5 Conto DPLV conto Defau FALS 01_to urs15 Elt po

More information

North Tarrant Express (NTE) 3B

North Tarrant Express (NTE) 3B Fugro Consultants, Inc. 2880 Virgo ane Tel: 972-484-8301 Dallas, Texas 75229 Fax: 972-620-7328 North Express (NTE) 3B Fugro Technical Memo No. 1 To: Jiri Filipovic, PE AECM Anthony Karlinski, PE - AECM

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report SH-9 Bridge over Wewoka Creek Hughes County, Oklahoma Job Piece No. 27059(04) July 16, 2015 Terracon Project No. 04125055 Prepared for: Holloway, Updike, and Bellen, Inc.

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Polecat Creek Bridge (Bridge A) June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Prepared by: Terracon Consultants, Inc. TABLE

More information

Preliminary Geotechnical Evaluation Gooseberry Point Pedestrian Improvements Whatcom County, Washington SITE AND PROJECT DESCRIPTION

Preliminary Geotechnical Evaluation Gooseberry Point Pedestrian Improvements Whatcom County, Washington SITE AND PROJECT DESCRIPTION File No. 12-100 Geotechnical & Earthquake Engineering Consultants Mr. Kevin Brown, P.E. Gray & Osborne, Inc. 3710 168 th Street NE, Suite B210 Arlington, Washington 98223 Subject: Draft Report Preliminary

More information

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky

Preliminary Geotechnical Investigation Cadiz / Trigg County I-24 Business Park. Cadiz, Kentucky Environmental & Geoscience, LLC 834 Madisonville Road Hopkinsville, KY 440 70.44.000 FAX 70.44.8300 www.wedrill.com A member of Trinity Energy & Infrastructure Group, LLC Preliminary Geotechnical Investigation

More information

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD

Project No: 68R3056 Client: City of Frederick Project: RFQ 14-H Future North Side Water Tank City/State: 7516 Hayward Road, Frederick, MD Boring: SB-1 (1 of 1) Moist, brown to orange brown CLAY and SILT, trace sand with fine weathered rock fragments. POSSIBLE FILL. Dry, orange brown sandy SILT trace clay (SM-ML). RESIDUAL SOIL : Not Surveyed

More information

DRILL HOLE # BH-BGC13-FN-01

DRILL HOLE # BH-BGC13-FN-01 DILL HOLE # BH-BGC3-FN-0 Drill Method: Mud otary/coring Depth To ock (m): N/A Page of 7 eviewed by: AJB 0 GAVEL (GW) Fine to coarse, sandy, well graded, dense, max particle size = 30 mm, angular to subrounded,

More information

Appendix A. Producer Statement Advisory Note

Appendix A. Producer Statement Advisory Note Appendix A Producer Statement Advisory Note Ref. No. 17095 26 May 2017 PRODUCER STATEMENT CONSTRUCTION REVIEW (PS4) IMPORTANT ADVISORY NOTE The Building Consent Authority (BCA) frequently requires Producer

More information

CONQUEST ENGINEERING LTD.

CONQUEST ENGINEERING LTD. CONQUEST ENGINEERING LTD. Geotechnical and Materials Engineers Concrete Technology, Blasting Consultants Construction Quality Assurance / Quality Control 8 Bluewater Road, Bedford, NS BB J6 Phone (9)85-7

More information

Geotechnical Engineering Subsurface Exploration The Proposed LAPLAWD Phase 2B 12 Main Water Line Durango, Colorado

Geotechnical Engineering Subsurface Exploration The Proposed LAPLAWD Phase 2B 12 Main Water Line Durango, Colorado July, La Plata Archuleta Water District c/o Harris Water Engeerg, P.E. East nd Avenue, Suite Durango, Colorado brett@durangowater.com PN: GE Subject: Geotechnical Engeerg Subsurface Exploration The Proposed

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Turner Turnpike Widening Bridge D Bridge Crossing: South 209 th West Avenue Creek County, Oklahoma June 1, 2016 Terracon Project No. 04155197 Prepared for: Garver, LLC Tulsa,

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION DRAINAGE IMPROVEMENTS TO THE HENDRY COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants OFFICES Orlando, 88 S. Orange Avenue, Orlando,

More information

Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG

Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG Parsons APPENDIX A BORING LOGS AND DEVELOPMENT LOG GEOLOGIC LOG DATE STARTED: DATE COMPLETED: 08-Sep-09 08-Sep-09 LOGGER: Quin Kinnebrew WEATHER: Clear & Warm PAGE 1 OF 2 WELL NO. GMW-66 COMPANY NAME:

More information

APPENDIX B: BORING LOGS

APPENDIX B: BORING LOGS New Orleans Levee Systems Independent Levee Hurricane Katrina Investigation Team July, 6 APPENDIX B: BORING S As part of the field investigation 9 borings were performed at the sites of interest, as listed

More information

LEGEND ODOT CLASS. A-4b. A-6a. A-6b TOTAL VISUAL WEATHERED SANDSTONE VISUAL BORING LOCATION - PLAN VIEW

LEGEND ODOT CLASS. A-4b. A-6a. A-6b TOTAL VISUAL WEATHERED SANDSTONE VISUAL BORING LOCATION - PLAN VIEW PROJECT THE PROJECT CONSISTS IN PART OF ACING TWO STRUCTURES, EASTBOUND AND WESTBOUND STRUCTURES, RESPECTIVELY FOR THE PROPOSED SR OVER BLUE ROAD (CR 9). THE TWO STRUCTURES AS ANNED, ARE SINGLE-SPAN STRUCTURES

More information

GEOLOGIC/GEOTECHNICAL INVESTIGATION FOR TENTATIVE MAP LAVENIDA SUBDIVISION (APN # ) ORINDA, CALIFORNIA

GEOLOGIC/GEOTECHNICAL INVESTIGATION FOR TENTATIVE MAP LAVENIDA SUBDIVISION (APN # ) ORINDA, CALIFORNIA GEOLOGIC/GEOTECHNICAL INVESTIGATION FOR TENTATIVE MAP LAVENIDA SUBDIVISION (APN #271-120-011) ORINDA, CALIFORNIA A 580 Ts 590 HMA-1 600 HMA-2 70 Ts 610 Ts HMA-3 HLA-5 GJA-6 LD-2 23

More information

NAPLES MUNICIPAL AIRPORT

NAPLES MUNICIPAL AIRPORT NAPLES MUNICIPAL AIRPORT NAPLES MUNICIPAL AIRPORT (APF) TAXIWAY D REALIGNMENT AND DRAINAGE IMPROVEMENTS NORTH QUADRANT ADDENDUM NUMBER TWO March, The following Addendum is hereby made a part of the Plans

More information

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants SUBSURFACE SOIL EXPLORATION ANALYSIS AND RECOMMENDATIONS LELY AREA STORMWATER IMPROVEMENT PROJECT (LASIP) COUNTY BARN ROAD AND WING SOUTH CHANNELS NAPLES, COLLIER CO., FLORIDA Ardaman & Associates, Inc.

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Single-Span Bridge North Western Road & Hall of Fame Avenue August 25, 2015 Terracon Project No. 03155156 Prepared for: Olsson Associates Prepared by: Terracon Consultants,

More information

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011

Report of Preliminary Geotechnical Exploration. CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio. February, 2011 11242843_GeoTech_Preliminary - Feburary 2011_1/40 Report of Preliminary Geotechnical Exploration CSO-012 Sewer Separation Cincinnati, Hamilton County, Ohio February, 2011 11242843_GeoTech_Preliminary -

More information

WELL NUMBER 14-BW03 PAGE 1 OF 5

WELL NUMBER 14-BW03 PAGE 1 OF 5 WELL 14-BW03 PAGE 1 OF 5 IENT PROJECT DATE STARTED 4/30/14 COMPLETED 5/1/14 GROUND ELEVATION 1157.89 ft HOLE SIZE 9 5/8 inches DRILLING CONTRACTOR Cascade Drilling NORTHING 670592.2 EASTING 1937845.8 DRILLING

More information

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014)

Hydro One (Sept 2014) Hydro One (Sept 2014) Hydro One (Sept 2014) TABLE 1 WELL CONSTRUCTION DETAILS MOE WWR No Well ID Location Installation Date Status Easting Coordinates Northing Source Elevation Screened Interval Screened Material Borehole Well Stick-up Ground Top

More information

CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: Contract No.: TO: All Recipients Date: April 14, 2014

CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: Contract No.: TO: All Recipients Date: April 14, 2014 CITY OF VALDEZ Project Title: East Pioneer Reconstruction Project No.: 13-3-1.32 Contract No.: 11 TO: All Recipients Date: April 14, 214 SUBJECT: Addendum No.1 This seventeen (17) page Addendum forms a

More information

B-1 SURFACE ELEVATION

B-1 SURFACE ELEVATION 5A 5B LOGGED BY El. S. Bhangoo DRILLING CONTRACTOR Pitcher Drilling DRILLING METHOD Rotary Wash BEGIN DATE 12-14-12 SAMPLER TYPE(S) AND SIZE(S) (ID) SPT, MC BOREHOLE BACKFILL AND COMPLETION COMPLETION

More information

February 16, 2015 File No Ms. Robin Yates TRC Engineers Inc N. Fresno Street, Suite 200 Fresno, California 93710

February 16, 2015 File No Ms. Robin Yates TRC Engineers Inc N. Fresno Street, Suite 200 Fresno, California 93710 February 16, 2015 File No. 20152738 Ms. Robin Yates TRC Engineers Inc. 6051 N. Fresno Street, Suite 200 Fresno, California 93710 SUBJECT: Geotechnical Design Memorandum Fresno BPMP Scour Countermeasure

More information

Dashed line indicates the approximate upper limit boundary for natural soils. C L o r O L C H o r O H

Dashed line indicates the approximate upper limit boundary for natural soils. C L o r O L C H o r O H SYMBOL SOURCE 8 9 1 SOIL DATA NATURAL SAMPLE DEPTH WATER PLASTIC LIQUID PLASTICITY NO. CONTENT LIMIT LIMIT INDEX (%) (%) (%) (%) Client: County of Berthoud Project: Project No.: Boring B-2 S-1-5' 6.2 8

More information

R-1 Conveyor Relocation Project Legend 0 500 1000 1500 ft. This map is a user generated static output from an Internet mapping site and is for general reference only. Data layers that appear on this map

More information

REPORT OF PRELIMINARY SUBSURFACE EXPLORATION. VCU Basketball Practice Facility 1300/1328 West Marshall Street City of Richmond, Virginia.

REPORT OF PRELIMINARY SUBSURFACE EXPLORATION. VCU Basketball Practice Facility 1300/1328 West Marshall Street City of Richmond, Virginia. REPORT OF PRELIMINARY SUBSURFACE EXPLORATION VCU Basketball Practice Facility 100/18 West Marshall Street City of Richmond, Virginia For Mr. Carl F. Purdin, AIA Assistant Director of Design Services VCU

More information

FIGURES 200 200 200 SW 175TH AVE 350 SW SCHOLLS FERRY RD SW FRIENDLY LN Area 64 SW ROY ROGERS RD 300 250 SW ONEILL CT SW LUKE LN SW LEEDING LN SW TUSCANY ST SW 164TH AVE SW BULL MOUNTAIN RD SW 164TH AVE

More information

Northern Colorado Geotech

Northern Colorado Geotech PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PROPOSED CECIL FARMS DEVELOPMENT WELD COUNTY ROAD 7, BETWEEN ROADS 7 AND 7 SEVERANCE, COLORADO NORTHERN COLORADO GEOTECH PROJECT NO. 0-6 APRIL 0, 06 Prepared

More information

PARQUE COLON AGUADILLA (LAND PROPERTY OF MUNICIPIO AGUADA) LOT PROPERTY OF SUNC. ESTEVEZ BW-1 BW-5 BW-2 DB1 BW-3 DB2 BW-4 DB3 GWS-1

PARQUE COLON AGUADILLA (LAND PROPERTY OF MUNICIPIO AGUADA) LOT PROPERTY OF SUNC. ESTEVEZ BW-1 BW-5 BW-2 DB1 BW-3 DB2 BW-4 DB3 GWS-1 N 64650 N 64600 N 64550 N 64500 N 64450 N 64400 N 64350 N 64300 N 64250 N 64200 N 64150 N 64100 N 64050 N 64000 N 63950 N 63900 N 63850 N 63800 N 63750 N 63700 N 63650 N 63600 N 63550 N 63500 N 63450 N

More information

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS

NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS NEW DOWN-HOLE PENETROMETER (DHP-CIGMAT) FOR CONSTRUCTION APPLICATIONS 1 2 C. Vipulanandan 1, Ph.D., M. ASCE and Omer F. Usluogullari 2 Chairman, Professor, Director of Center for Innovative Grouting Materials

More information

Log of Monitoring Well D58B

Log of Monitoring Well D58B Project: Motiva - Monitoring Well and Soil Boring Data Project Location: Delaware City Refinery Project Number: 20240412.W1000 Log of Monitoring Well D58B Sheet 1 of 7 Date(s) Drilled Drilling Method Drill

More information

CITY OF CAPE CORAL NORTH 2 UTILITIES EXTENSION PROJECT CONTRACT 3

CITY OF CAPE CORAL NORTH 2 UTILITIES EXTENSION PROJECT CONTRACT 3 GEOTECHNICAL REPORT CITY OF CAPE CORAL NORTH UTILITIES EXTENSION PROJECT CONTRACT City of Cape Coral Procurement Division Cultural Park Boulevard, nd Floor Cape Coral, FL ISSUED FOR BID VOLUME of GEOTECHNICAL

More information

IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION

IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION IN SITU SPECIFIC GRAVITY VS GRAIN SIZE: A BETTER METHOD TO ESTIMATE NEW WORK DREDGING PRODUCTION Nancy Case O Bourke, PE 1, Gregory L. Hartman, PE 2 and Paul Fuglevand, PE 3 ABSTRACT In-situ specific gravity

More information

Clay Robinson, PhD, CPSS, PG copyright 2009

Clay Robinson, PhD, CPSS, PG   copyright 2009 Engineering: What's soil got to do with it? Clay Robinson, PhD, CPSS, PG crobinson@wtamu.edu, http://www.wtamu.edu/~crobinson, copyright 2009 Merriam-Webster Online Dictionary soil, noun 1 : firm land

More information

Assistant Chief-Bureau of Structures and Geotechnical Services

Assistant Chief-Bureau of Structures and Geotechnical Services MEMO DATE: 2/10//2016 Bureau of Structures and Geotechnical Services TO: John Jones, P.E. Assistant Chief-Bureau of Structures and Geotechnical Services ATTENTION: Mark Hurt, P.E. Senior Bridge Squad Leader

More information

Geotechnical Aspects of the Ohio River Bridges Project

Geotechnical Aspects of the Ohio River Bridges Project Geotechnical Aspects of the Ohio River Bridges Project Mark A. Litkenhus, PE Sr. Geotechnical Engineer Stephen H. Bickel, PE Sr. Geotechnical Engineer STGEC Ohio River Bridges at Louisville Geotechnical

More information

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming

Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus Laramie, Wyoming Limited Geotechnical Engineering Evaluation Classroom Additions Albany County Campus 2300 Missile Drive, Cheyenne, Wyoming 82001 Phone 307-635-0222 www.stratageotech.com Limited Geotechnical Engineering

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report S-38-50 (Four Holes Road) over I-26 Emergency Bridge Replacement Orangeburg County, South Carolina May 22, 2018 (Revision 1) SCDOT Project ID.: P037465 Terracon Project No. 73155050U

More information

Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project

Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project TECHNICAL MEMORANDUM Geotechnical Recommendations for Proposed Additions to the Three Mile Creek Severe Weather Attenuation Tank Project PREPARED FOR: PREPARED BY: DATE: June 28, 218 PROJECT NUMBER: 697482

More information

Geotechnical Data Report

Geotechnical Data Report Geotechnical Data Report ReWa Solar Farm at Durbin Creek Fountain Inn, South Carolina September 1, 2017 Terracon Project No. 86165043 Prepared for: Renewable Water Resources Greenville, South Carolina

More information

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California

SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource Evaluation Proposed Bernand Quarry San Diego County, California October 3, 2 Mr. Mark San Agustin Project No. 28-- Home Land Investments Document No. -92 2239 Curlew Street San Diego, CA 92 SUBJECT: SUPPLEMENTARY INVESTIGATION AND LABORATORY TESTING Aggregate Resource

More information

Technical Memorandum. Soil Borings

Technical Memorandum. Soil Borings Technical Memorandum To: Project File and Appendix F to Sediment Remedial Investigation Report From: Sara L. Leow, PE Subject: Geotechnical Investigation and Results Summary Date: February 213 Project:

More information

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT PRELIMINARY GEOTECHNICAL ENGINEERING REPORT TOWN OF ASHLAND TOWN HALL 101 THOMPSON STREET ASHLAND, VIRGINIA JOB NUMBER: 39016 PREPARED FOR: PMA PLANNERS & ARCHITECTS 10325 WARWICK BOULEVARD NEWPORT NEWS,

More information

Dundy County Test Hole Logs

Dundy County Test Hole Logs University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Conservation and Survey Division Natural Resources, School of 2007 Test Hole Logs Duane A. Eversoll University of Nebraska-Lincoln

More information

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No.

PRELIMINARY GEOTECHNICAL REPORT. State College Redevelopment State College Borough, Centre County, Pennsylvania. CMT Laboratories File No. PRELIMINARY GEOTECHNICAL REPORT State College Redevelopment State College Borough, Centre County, Pennsylvania CMT Laboratories File No. 1638700 Prepared for: National Development Council One Battery Park

More information

Geotechnical Engineering Report

Geotechnical Engineering Report Geotechnical Engineering Report Richland Creek Trunk Sewer Greenville, South Carolina March 31, 2014 Terracon Project No. 86145008 Prepared for: Renewable Water Resources Greenville, South Carolina Prepared

More information

3.0 SUMMARY OF FINDINGS

3.0 SUMMARY OF FINDINGS AECOM 500 W Jefferson St. Suite 1600 Louisville, KY 40202 www.aecom.com 502-569-2301 tel 502-569-2304 fax October 17, 2018 Big Rivers Electric Corporation Sebree Generating Station 9000 Highway 2096 Robards,

More information

71912 From: Dana Derrington Sent: Wednesday, May 31, :02 PM Central Standard Time TO:

71912 From: Dana Derrington Sent: Wednesday, May 31, :02 PM Central Standard Time TO: Blue, Karen From: Sent: To: Subject: Attachments: Categories: Hynum, Tammie Wednesday, May 31, 17 6:21 PM Sadler, Bill; Cusher, Annette; Rich, Jay FW: Monitoring Well Installation Report, Entergy White

More information

Terraprobe Consulting Geotechnical & Environmental Engineering Construction Materials Inspection & Testing

Terraprobe Consulting Geotechnical & Environmental Engineering Construction Materials Inspection & Testing Terraprobe Consulting Geotechnical & Environmental Engineering Construction Materials Inspection & Testing GEOTECHNICAL INVESTIGATION BLOCKS TO PIER HAMILTON, ONTARIO PREPARED FOR: City of Hamilton Waterfront

More information

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado

Geotechnical Engineering Study, Conifer Senior High School Football Field Improvements, Conifer, Colorado 2390 South Lipan Street Denver, CO 80223 phone: (303) 742-9700 fax: (303) 742-9666 email: kadenver@kumarusa.com www.kumarusa.com Office Locations: Denver (HQ), Colorado Springs, Fort Collins, and Frisco,

More information

Soil Mechanics Brief Review. Presented by: Gary L. Seider, P.E.

Soil Mechanics Brief Review. Presented by: Gary L. Seider, P.E. Soil Mechanics Brief Review Presented by: Gary L. Seider, P.E. 1 BASIC ROCK TYPES Igneous Rock (e.g. granite, basalt) Rock formed in place by cooling from magma Generally very stiff/strong and often abrasive

More information

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPT CAPITAL REGION RESOURCE RECOVERY CENTRE APPENDIX A Borehole Records December Report No. //vol III LIST OF ABBREVIATIONS The abbreviations coonly employed

More information

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska.

GEOTECHNICAL REPORT. Matanuska-Susitna Borough. Parks Highway Connections Museum Drive. Matanuska-Susitna Borough, Alaska. Matanuska-Susitna Borough GEOTECHNICAL REPORT Parks Highway Connections Museum Drive Matanuska-Susitna Borough, Alaska March 2, 20 Prepared By: John Thornley, PE Geotechnical Engineer 333 Arctic Blvd.,

More information

o - 399' ' ' ' ' T. D.

o - 399' ' ' ' ' T. D. Ii I I' I: VDMRWellNo W-1142 Operator: J W Miloncus Farm: Browning Wynn Well No. : 1 Location: Lee County 3300' N of 36 042'30" 1800' E of 83005' approx Elevation: 1975' (reported altimeter elevation)

More information

AN EMPLOYEE OWNED COMPANY

AN EMPLOYEE OWNED COMPANY CTL Engineering, Inc. 2860 Fisher Road, P.O. Box 4448, Columbus, Ohio 43204338 Phone: 614/2768123 Fax: 614/2766377 Email: ctl@ctleng.com AN EMPLOYEE OWNED COMPANY Consulting Engineers Testing Inspection

More information

GEOTECHNICAL ENGINEERING SERVICES REPORT

GEOTECHNICAL ENGINEERING SERVICES REPORT GEOTECHNICAL ENGINEERING SERVICES REPORT BRIDGE OVER BIG CREEK APPROXIMATELY.8 MILES EAST OF THE INTERSECTION OF COUNTY ROAD EW1546 AND COUNTY ROAD 193 LEFLORE COUNTY, OKLAHOMA PROJECT No. J2-8616(5),

More information

Class Principles of Foundation Engineering CEE430/530

Class Principles of Foundation Engineering CEE430/530 Class Principles of Foundation Engineering CEE430/530 1-1 General Information Lecturer: Scott A. Barnhill, P.E. Lecture Time: Thursday, 7:10 pm to 9:50 pm Classroom: Kaufmann, Room 224 Office Hour: I have

More information

SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO.

SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO. SUBSURFACE EXPLORATION REPORT FOR THE MARITIME INFRACTURE REHABILITATION AT WHISKEY ISLAND BULK TERMINAL CLEVELAND, OHIO PGI PROJECT NO. G1G PREPARED FOR KS ASSOCIATES, INC. PREPARED BY PRO GEOTECH, INC.

More information

10 May Rod Walls - Director Facilities New Construction, Sustainability Hays CISD IH 35 Kyle, Texas 78640

10 May Rod Walls - Director Facilities New Construction, Sustainability Hays CISD IH 35 Kyle, Texas 78640 10 May 2017 Rod Walls - Director Facilities New Construction, Sustainability Hays CISD 21003 IH 35 Kyle, Texas 78640 Re: Hays CISD Proposed ES15 Site, Buda Phase II Soil Sampling Dear Rod: Concern has

More information

Solution:Example 1. Example 2. Solution: Example 2. clay. Textural Soil Classification System (USDA) CE353 Soil Mechanics Dr.

Solution:Example 1. Example 2. Solution: Example 2. clay. Textural Soil Classification System (USDA) CE353 Soil Mechanics Dr. CE353 Soil Mechanics CE353 Lecture 5 Geotechnical Engineering Laboratory SOIL CLASSIFICATION Lecture 5 SOIL CLASSIFICATION Dr. Talat A Bader Dr. Talat Bader 2 Requirements of a soil Systems Why do we need

More information

INVITATION TO BID CITY OF CAPE CORAL SW 6&7 UTILITIES EXTENSION PROJECT CONTRACT VII CENTRAL AREA 6 AND CENTRAL AREA 8 ITB UT13-02/TM-G

INVITATION TO BID CITY OF CAPE CORAL SW 6&7 UTILITIES EXTENSION PROJECT CONTRACT VII CENTRAL AREA 6 AND CENTRAL AREA 8 ITB UT13-02/TM-G GEOTECHNICAL REPORT INVITATION TO BID CITY OF CAPE CORAL SW 6&7 UTILITIES EXTENSION PROJECT CONTRACT VII CENTRAL AREA 6 AND CENTRAL AREA 8 ITB UT13-02/TM-G City of Cape Coral Procurement Division 1015

More information

THE STRUCTURE AND THICKNESS OF THE CLINTON AND BEREA FORMATIONS IN THE VICINITY OF WOOSTER, OHIO

THE STRUCTURE AND THICKNESS OF THE CLINTON AND BEREA FORMATIONS IN THE VICINITY OF WOOSTER, OHIO THE STRUCTURE AND THICKNESS OF THE CLINTON AND BEREA FORMATIONS IN THE VICINITY OF WOOSTER, OHIO KARL VER STEEG College of Wooster INTRODUCTION AND ACKNOWLEDGMENTS The data used in the construction of

More information

ENGINEERING ASSOCIATES

ENGINEERING ASSOCIATES July 16, 211 Vista Design, Inc. 11634 Worcester Highway Showell, Maryland 21862 Attention: Reference: Dear Mr. Polk: Mr. Richard F. Polk, P.E. Geotechnical Engineering Report Charles County RFP No. 11-9

More information

u. S. Geological Survey,

u. S. Geological Survey, VDMR Well No. Operator: Southwestern Oil and 'Gas Company Farm: Hagan Well No.: 1 Location: Wise County 9300' S. of 36 055') 600' E. of 82030,)approximate Elevation: 2500' Total Depth:3751' Drill'ing Comrilenced:

More information

6.2 Geotechnical Investigation and Construction Material Survey

6.2 Geotechnical Investigation and Construction Material Survey 6.2 Geotechnical Investigation and Construction Material Survey Geological surveys and investigations were conducted to obtain information on the subsurface geological condition required for the preliminary

More information

TIERRA. Florida License No Florida License No

TIERRA. Florida License No Florida License No March 9, 208 TIERRA AECOM 7650 West Courtney Campbell Cswy Tampa, FL 33607 Attn: RE: Mr. Edgar Figueroa, P.E. Geotechnical Engineering Services Report Purchase Order No.: 9532 AECOM Project Number: 6055499

More information

APPENDIX E SOILS TEST REPORTS

APPENDIX E SOILS TEST REPORTS Otsego County, NY Site Work Specifications APPENDIX E SOILS TEST REPORTS Blue Wing Services, Inc. July 1, 2010 Blue Wing Services May 20, 2010 Page 2 the site, was not made available to Empire at this

More information

Appendix F Laboratory test results

Appendix F Laboratory test results Appendix F Laboratory test results SOIL AND ROCK SAMPLE ANALYSIS LABORATORY TEST REPORT To: Bord Gais Copy: Orla Smyth (kkidd@bge.ie) From: Stephen Watson Laboratory Manager Causeway Geotech Ltd Tel: +44(0)2827666640

More information

REPORT OF SUBSURFACE EXPLORATION

REPORT OF SUBSURFACE EXPLORATION REPORT OF SUBSURFACE EXPLORATION GRAND RIVER DAM AUTHORITY HULBERT 69 KV SWITCHING STATION S. 440 Road Hulbert, Cherokee County, Oklahoma ENERCON PROJECT NO. GRDA006 MARCH 7, 2012 PREPARED FOR: C/O ENERCON

More information

GZA GeoEnvironmental, Inc.

GZA GeoEnvironmental, Inc. GZA BORING NO.: GZ-1 SHEET: 1 of 1 PROJECT NO: 9.223. Drilling Co.: Geologic Type of Rig: Skid Boring Location: See Plan H. Datum: See Plan Rig Model: Mudline : Foreman: Ray Eastwood CME -.8 Final Boring

More information