Alltech Alltima HP Introduction

Size: px
Start display at page:

Download "Alltech Alltima HP Introduction"

Transcription

1 Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life exceptional column stability minimizes downtime and reduces cost Ideal for Microbore or Critical Analysis low to no detectable column bleed Variety of Phases and Formats optimizes retention, resolution, and analysis time Alltima HP combines our best phase chemistries with high-purity silica. The result is one product family with selectivity and performance needed to overcome your most challenging separation needs. Alltech Alltima HP Phase Specifications Pore Size Surface Area Carbon Load Endcapped? Phase Description Base Particle Particle Size Phase USP C8 For classic reversed-phase applications Silica Spherical, μm 90Å 00 m /g % Monomeric Yes L C8 EPS Reversed-phase C8 with extended polar selectivity Silica Spherical, μm 90Å 00 m /g % Monomeric Yes L C8 HiLoad Higher carbon load for stronger retention Silica Spherical, μm 00Å 0 m /g % Monomeric Yes L C8 AQ 00% water wettable Silica Spherical, μm 00Å 0 m /g 0% Monomeric Yes L C8 Amide Low bleed polar-embedded phase compatible Silica Spherical, μm 90Å 00 m /g % Monomeric Yes L with microbore C8 For reversed-phase applications where C8 is Silica Spherical, μm 90Å 00 m /g 8% Monomeric Yes L7 too retentive Cyano Stable, long-life cyano phase Silica Spherical, μm 90Å 00 m /g % Monomeric Yes L0 Silica For general purpose normal-phase applications Silica Spherical, μm 00Å 0 m /g No L HILIC Hydrophillic Interaction Chromatography for highly polar analytes Silica Spherical.,, μm 0Å 0 m /g L Basic Compounds at Neutral ph 0 7 Min. The Alltima HP phases demonstrate excellent peak symmetry of highly basic analytes at ph 7.0. Peak USP Tailing*. Diphenhydramine.9. Nortriptyline.. Amitriptyline.7 *Tailing Factor was determined in accordance with USP method. Column: Alltima HP C8, μm,. x 0mm Mobile Phase: mm Potassium Phosphate, ph 7.0:Methanol (:8) Flow Rate:.0mL/min Detector: UV at nm Basic Compound Stability at ph and ph0 Final Acid Final Base Retention Times. Uracil Phenol N,N-Diethyl-m-Toluamide Toluene Column: Alltima HP C8, μm,. x 0mm Mobile Phase: Acetonitrile:Water (8:) Flow Rate:.0mL/min Detector: UV at nm Final Acid: washed with,000 column volumes of Acetonitrile:Dilute Sulfuric Acid, ph.0 (0:0) at 0 C. Final Base: washed with,000 column volumes of Acetonitrile:Ammonium Hydroxide, ph 0 (0:0) at 0 C. Initial 0 Min. The Alltima HP phases demonstrate exceptional stability from ph.0 to

2 Alltech Introduction The Alltima HP Family Demonstrates Low Bleed Alltima HP columns are among the lowest-bleed columns available, making them ideal for microbore applications. Our C8 Amide polar-embedded phase has significantly lower column bleed than competitive amide columns. Relative Abundance Level (X0 ) 0 8 Column Bleed by ESI-MS Alltima HP vs. Competitive Columns Alltech Competitors No Column Silica C8 C8 HiLoad C8 MS C8 MS C8 Amide C8 Amide C8 Amide Method Development Kits best value Three Different Kits with Different Selectivities Whether you are developing a new method, or just not satisfied with an existing separation, the Alltima HP family can help optimize your separation. Your best value for method development purchase a kit and receive three columns for the price of two Alltima HP Method Development Kits Description Includes: i.d. x Length Part No. Kit C8 Mix, μm Expedite MS Kit C8, C8 HiLoad, C8 Amide (877, 879, 8778). x 0mm 878 Analytical Kit C8, C8 HiLoad, C8 Amide (878, 878, 877). x 0mm 8780 Rocket Kit C8, C8 HiLoad, C8 Amide (877, 8790, 877) 7 x mm 878 Kit Alternate Mix, μm Expedite MS Kit C8 HiLoad, C8, CN (879, 877, 877). x 0mm 878 Analytical Kit C8 HiLoad, C8, CN (878, 8770, 8770). x 0mm 8780 Rocket Kit C8 HiLoad, C8, CN (8790, 877, 877) 7 x mm 878 Kit Polar Mix, μm Expedite MS Kit C8 EPS, C8 Amide, CN (8770, 8778, 877). x 0mm 8787 Analytical Kit C8 EPS, C8 Amide, CN (8770, 877, 8778). x 0mm Rocket Kit C8 EPS, C8 Amide, CN (87708, 877, 877) 7 x mm 8787 tech tip Want high throughput on a conventional (non-ultra high-pressure) system? Choose the Rocket column format no modifications necessary to your existing HPLC system. Choose Expedite columns for low volume and microbore systems. See page for more explanation of the Rocket and Expedite formats. 9

3 0 Alltech Reversed-Phase Columns Selectivity Options in One Product Family C8: Classic reversed-phase retention and selectivity C8 AQ: 00% water wettable and high carbon loading for greater mobile phase range EPS C8: Unique selectivity that succeeds when traditional reversed-phase columns fail Greater retention and enhanced peak symmetry for polar compounds C8 HiLoad: Superior retention and loadability for resolution of complex samples C8 Amide: The first polar-embedded packing ideal for microbore Excellent peak shape without phase bleed Ideal for basic compounds in neutral to alkaline ph C8: Less hydrophobic retention than C8 Alltima HP Selectivity Alltima HP Packing Acid, Base, and Neutral Test Mix 0 8 Min. Column:. x 0mm Mobile Phase: 0mM KHPO, ph.0:chcn (0:0) Column Temp: Ambient ( C) Flow Rate:.0mL/min Injection Vol.: μl Detector: UV at nm Uracil. Pyridine. Phenol. N,N-diethyl-m-toluamide. -Butyl Benzoic Acid. Toluene C8 EPS C8 C8 HiLoad Alltima HP HPLC Columns C8, μm* Capillary 0.0 X 0mm Capillary 0.0 X00mm Capillary 0.0 X0mm Capillary 0.00 X 0mm Capillary 0.00 X00mm 7 Capillary 0.00 X0mm 8 Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Microbore. x 0mm 870 Microbore. x 00mm 879 Microbore. x 0mm 8770 Solvent-Reducer.0 x 0mm 870 Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Analytical. x 0mm 878 Analytical. x 00mm 877 Analytical. x 0mm 878 Rocket 7 x mm 877 Rocket 7 x mm 877 C8, μm Microbore. x 0mm 878 Microbore. x 0mm 878 Solvent-Reducer.0 x 0mm 870 Solvent-Reducer.0 x 0mm 870 Analytical. x 0mm 8779 Analytical. x 0mm 8780 C8 AQ, μm* Capillary 0.0 x 0mm 0 Capillary 0.0 x 00mm Capillary 0.0 x 0mm Capillary 0.00 x 0mm Capillary 0.00 x 00mm Capillary 0.00 x 0mm Expedite MS. x 0mm 878 Expedite MS. x 0mm 878 Microbore. x 00mm Microbore. x 0mm 8780 Expedite MS. x 0mm 878 Expedite MS. x 0mm 878 Analytical. x 0mm 878 Analytical. x 00mm Analytical. x 0mm Rocket 7 x mm 878 Rocket 7 x mm 878 C8 AQ, μm Microbore. x 0mm 878 Microbore. x 0mm 878 Analytical. x 0mm 8789 Analytical. x 0mm 8780 C8 EPS, μm Expedite MS. x 0mm Expedite MS. x 0mm 8770 Microbore. x 0mm 8708 Microbore. x 00mm 8770 Microbore. x 0mm 8770 Solvent-Reducer.0 x 0mm 870 Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Analytical. x 0mm 878 Analytical. x 00mm 8770 Analytical. x 0mm 8770 Rocket 7 x mm Rocket 7 x mm C8 EPS, μm Microbore. x 0mm 8777 Microbore. x 0mm 8778 Solvent-Reducer.0 x 0mm 870 Solvent-Reducer.0 x 0mm 870 Analytical. x 0mm 877 Analytical. x 0mm 877 *Other particle sizes and dimensions are available.

4 Alltech Reversed-Phase Columns Alltima HP HPLC Columns (continued) C8 Hi-Load, Capillary 0.0 x 0mm 90 μm* Capillary 0.00 x 0mm 9 Expedite MS. x 0mm 879 Expedite MS. x 0mm 879 Microbore. x 0mm 870 Microbore. x 00mm 8787 Microbore. x 0mm 8788 Solvent-Reducer.0 x 0mm 870 Expedite MS. x 0mm 879 Expedite MS. x 0mm 879 Analytical. x 0mm 8787 Analytical. x 00mm 878 Analytical. x 0mm 878 Rocket 7 x mm 8789 Rocket 7 x mm 8790 C8 Hi-Load, Microbore. x 0mm 8799 μm Microbore. x 0mm Solvent-Reducer.0 x 0mm 87 Solvent-Reducer.0 x 0mm 87 Analytical. x 0mm 8797 Analytical. x 0mm 8798 C8 Amide, Capillary 0.0 x 0mm μm* Capillary 0.00 x 0mm 8 Expedite MS. x 0mm 8777 Expedite MS. x 0mm 8778 Microbore. x 0mm 870 Microbore. x 00mm 877 Microbore. x 0mm 877 Solvent-Reducer.0 x 0mm 8707 Expedite MS. x 0mm 8779 Expedite MS. x 0mm 8770 Analytical. x 0mm 8789 Analytical. x 00mm 877 Analytical. x 0mm 877 Rocket 7 x mm 877 Rocket 7 x mm 877 C8 Amide, Microbore. x 0mm 877 μm Microbore. x 0mm 877 Solvent-Reducer.0 x 0mm 8708 Solvent-Reducer.0 x 0mm 8709 Analytical. x 0mm 877 Analytical. x 0mm 877 C8, μm* Capillary 0.0 x 0mm 79 Capillary 0.0 x 00mm 80 Capillary 0.0 x 0mm 8 Capillary 0.00 x 0mm 8 Capillary 0.00 x 00mm 8 Capillary 0.00 x 0mm 8 Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Microbore. x 0mm 87 Microbore. x 00mm 877 Microbore. x 0mm 877 Solvent-Reducer.0 x 0mm 87 Expedite MS. x 0mm 8777 Expedite MS. x 0mm 8778 Analytical. x 0mm 8780 Analytical. x 00mm 8779 Analytical. x 0mm 8770 Rocket 7 x mm 877 Rocket 7 x mm 877 C8, μm Microbore. x 0mm 877 Microbore. x 0mm 877 Solvent-Reducer.0 x 0mm 87 Solvent-Reducer.0 x 0mm 87 Analytical. x 0mm 877 Analytical. x 0mm 877 *Other particle sizes and dimensions are also available. Alltima HP-Guard Cartridges Packing i.d. x Length Qty. Part No. C8 Capillary Guard, μm** 0.0 x 0mm ea x 0mm ea 79 C8 All-Guard, μm*. x 7.mm x 7.mm 87. x 7.mm 878 C8 AQ Capillary Guard, μm** 0.0 x 0mm ea x 0mm ea 9 C8 AQ All-Guard, μm*. x 7.mm 878. x 7.mm 878 C8 EPS All-Guard, μm*. x 7.mm x 7.mm 87. x 7.mm 8770 C8 Hi-Load Capillary 0.0 x 0mm ea 88 Guard, μm** 0.00 x 0mm ea 89 C8 Hi-Load All-Guard, μm*. x 7.mm x 7.mm 87. x 7.mm 8770 C8 Amide Capillary 0.0 x 0mm ea 98 Guard, μm** 0.00 x 0mm ea 99 C8 Amide All-Guard, μm*. x 7.mm x 7.mm 87. x 7.mm 8778 C8 Capillary Guard, μm** 0.0 x 0mm ea x 0mm ea 8 C8 All-Guard, μm*. x 7.mm x 7.mm 877. x 7.mm 877 All-Guard Cartridge Holder ea 800 (Includes Direct-Connect Column Coupler) Capillary Guard Cartridge Holder Guard Holder for 0.00mm and 0.0mm Guards ea GR-70E Guard Holder for 0.00mm and 0.00mm Guards ea GR-70A *All-Guard holder required. **Other particle sizes and dimensions are available. tech tip Which guard format should I choose? Ideally, the guard should have the same or slightly smaller i.d. as the HPLC column. Efficiency will suffer, if the guard i.d. is larger than that of the column. technical assistance Contact Tech Support: Phone: (North America) contact.alltech@grace.com Online:

5 Alltech HILIC Columns Hydrophilic Interaction (HILIC) Columns for Highly Polar Basic Analytes Superior retention of highly polar compounds Increased sensitivity and lower detection limits with microbore Available in.μm particle size Hydrophilic Interaction Chromatography is ideal for separating and retaining very polar compounds that may not retain on traditional reversed-phase packings. Unlike reversed-phase columns, HILIC columns retain highly polar compounds with only small amounts of water in the mobile phase. These more volatile mobile phases increase sensitivity with microbore applications. Basic Drugs Reverse-Phase C8 Columns Min. Column: Mobile Phase: Flow Rate: Detector: Mixed Analyte HILIC. Toluene. Hydantoin. Uracil. Caffeine. Allantoin Alltima HP HILIC, μm,. x 0mm (Part No. 8) Acetonitrile:0.0M Ammonium Formate, ph.0 (9:).0mL/min UV at 0nm 0 Alternate selectivity compared to reversed-phase columns allows more separation possibilities. HILIC Columns Min.. Albuterol. Bamethan Column: Prevail C8 Column, μm,. x 0mm (Part No. 9908) Alltima HP HILIC Column, μm,. x 0mm, (Part No. 8) Mobile Phase: 0.M Ammonium Formate, ph.0:chcn (88:) Acetonitrile:0.M Ammonium Formate, ph.0 (8:) Flow Rate:.0mL/min Detector: UV at 0nm Use Alltima HP HILIC's alternate selectivity for greater separation possibilities. tech tip Want high throughput on a conventional (non-ultra high-pressure) system? Choose the Rocket column format no modifications necessary to your existing HPLC system. Choose Expedite columns for low volume and microbore systems. See page for more explanation of the Rocket and Expedite formats. Rocket Columns 90 Expedite Columns Alltima HP HILIC HPLC Columns HILIC,.μm Expedite MS. x 0mm 87 Expedite MS. x 0mm 87 Rocket 7 x mm 87 Rocket 7 x mm 88 HILIC, μm* Capillary 0.0 x 0mm Capillary 0.0 x 00mm Capillary 0.0 x 0mm 7 Capillary 0.00 x 0mm 8 Capillary 0.00 x 00mm 9 Capillary 0.00 x 0mm 0 Expedite MS. x 0mm 87 Expedite MS. x 0mm 87 Microbore. x 0mm 8 Microbore. x 0mm 8 Expedite MS. x 0mm 87 Expedite MS. x 0mm 87 Analytical. x 0mm 80 Analytical. x 0mm 8 Rocket 7 x mm 89 Rocket 7 x mm 870 HILIC, μm Microbore. x 0mm 8 Analytical. x 0mm 8 Analytical. x 0mm 8 *Other particle sizes and dimensions are available. Alltima HP HILIC Guard Cartridges Packing i.d. x Length Qty. Part No. HILIC Capillary Guard, 0.0 x 0mm ea 8 μm** 0.00 x 0mm ea 9 HILIC All-Guard, μm*. x 7.mm 879. x 7.mm 880 All-Guard Cartridge Holder ea 800 (Includes Direct-Connect Column Coupler) Capillary Guard Cartridge Holder Guard Holder for 0.00mm and 0.0mm Guards ea GR-70E Guard Holder for 0.00mm and 0.00mm Guards ea GR-70A *All-Guard holder required. **Other particle sizes and dimensions are available.

6 Alltech Normal-Phase Columns Cyano: Superior stability More reproducible separations than silica for normal-phase applications Ideal for basic drug analysis Silica: Normal phase % Changes in Retention QC D Test: Alltima HP Cyano Much More Stable than Other Cyanos ph.0 ph 7. CN Brand A CN Brand B CN Brand C CN Brand D CN Brand E CN Brand F CN 70:0 HO/CHCN,.0mL/min, UV at nm, μl DMix, Column. x 0mm, C ph.0 Stability: Flushed with HSO ph.0:acetonitrile 0:0 at.0ml/min for days ph 7. Stability: Flushed with 0mM KHPO ph 7.:Acetonitrile 0:0 at.0ml/min for days Alltima HP HPLC Columns Cyano, μm Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Microbore. x 0mm 87 Microbore. x 00mm 8779 Microbore. x 0mm 8770 Solvent-Reducer.0 x 0mm 87 Expedite MS. x 0mm 877 Expedite MS. x 0mm 877 Analytical. x 0mm 878 Analytical. x 00mm 8777 Analytical. x 0mm 8778 Rocket 7 x mm 877 Rocket 7 x mm 877 Cyano, μm Microbore. x 0mm 8778 Microbore. x 0mm 8778 Solvent-Reducer.0 x 0mm 877 Solvent-Reducer.0 x 0mm 878 Analytical. x 0mm 8779 Analytical. x 0mm Silica, μm Expedite MS. x 0mm 8779 Expedite MS. x 0mm 8779 Microbore. x 0mm 87 Microbore. x 00mm Microbore. x 0mm Solvent-Reducer.0 x 0mm 879 Expedite MS. x 0mm 8779 Expedite MS. x 0mm 8779 Analytical. x 0mm 878 Analytical. x 00mm 8778 Analytical. x 0mm 8778 Rocket 7 x mm Rocket 7 x mm Deoxycorticosterone Acetate. Hydrocortisone Acetate. Cortisone Acetate. Cortisone Corticosteroids Min. Column: Alltima HP CN, μm,. x 0mm (Part No. 8779) Mobile Phase: Hexane:Isopropanol (9.7:.) Flow Rate:.0mL/min Column Temp: C Detector: UV at nm. Prednisone. Hydrocortisone 7. Prednisolone 7 09 Alltima HP HPLC Columns (continued) Silica, μm Microbore. x 0mm Microbore. x 0mm 8780 Solvent-Reducer.0 x 0mm 870 Solvent-Reducer.0 x 0mm 87 Analytical. x 0mm Analytical. x 0mm Alltima HP All-Guard Cartridges* Packing i.d. x Length Qty. Part No. Cyano, μm. x 7.mm x 7.mm 87. x 7.mm 8778 Silica, μm. x 7.mm x 7.mm 878. x 7.mm 8780 All-Guard Cartridge Holder ea 800 (Includes Direct-Connect Column Coupler) *All-Guard holder required. Other particle sizes available. more applications To view our complete searchable chromatogram database visit

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

CLIPEUS - A Small Shield for a Big Job

CLIPEUS - A Small Shield for a Big Job CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Kromasil Eternity Designed for long life

Kromasil Eternity Designed for long life Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Silanol. Groups Liquid Chromatography

Silanol. Groups Liquid Chromatography Abstract umber: 0-8P Study of Secondary Interaction Based on Residual lanol Groups for Reversed-Phase Liquid Chromatography II orikazu agae Ph.D, Kouji Yamamoto, Chiaki Kadota Chromaik Technologies Inc.

More information

BETASIL Columns TG Å high purity silica

BETASIL Columns TG Å high purity silica BETASIL Columns TG0-0 00Å high purity silica Technical Guide BETASIL Columns Introduction 00Å high purity silica High surface area and phase loading Designed for small molecules Type B silica gives good

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction Edouard S. P. Bouvier, Randy E. Meirowitz and Uwe D. Neue Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented

More information

C18 Column. Care & Use Sheet

C18 Column. Care & Use Sheet C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin

More information

IC Columns Introduction

IC Columns Introduction IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Chromatography Essentials. HPLC Flash TLC GC SPE

Chromatography Essentials. HPLC Flash TLC GC SPE Chromatography Essentials HPLC Flash TLC GC SPE W. R. Grace Grace is a leading global supplier of catalysts, packaging materials and specialty construction materials. The company s three industry-leading

More information

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46> High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

mau 200 ph min

mau 200 ph min mau ph - 6 8 TAKE A LOOK INSIDE TWIN Technology TWIN (Two-In-One ) Technology is what gives Gei its superior performance edge. During the final stage of silica manufacturing, a unique silica-organic layer

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which

More information

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT KromasilSFC Designed for green technology Introducing Kromasil SFC XT Basedon00Åporesize,.andµmparticles,KromasilSFC columns give users the opportunity of fast separations. The columns are tailor-made

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Next Generation of Phenyl Columns. Chromatography Products.

Next Generation of Phenyl Columns. Chromatography Products. Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both

More information

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

TLC Introduction. tlc Choose Stationary Phase. Select Visualization Technique. Choose a Mobile Phase

TLC Introduction. tlc Choose Stationary Phase. Select Visualization Technique. Choose a Mobile Phase TLC Introduction Thin Layer Chromatography to Preparative Chromatography One of the first steps in scale-up of preparative liquid chromatography separations is selection of an appropriate mobile phase.

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WAX-1 Columns User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

Setting the Standard for ph Method Development

Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic

More information

Passion. Power. Productivity.

Passion. Power. Productivity. - - Passion. Power. Productivity. Acclaim Acclaim Acclaim PA/PA Acclaim A Acclaim Acclaim PA Acclaim Explosives rdering and Warranty Information In the U.S. All rders Including: Credit Card rders (VISA,

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s

More information

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion HPLC Columns Agilent for Small Molecule InfinityLab Poroshell 0 ZORBAX Eclipse Plus ZORBAX Eclipse XDB ZORBAX 80Å StableBond ZORBAX 80Å Extend-C8 ZORBAX Bonus-RP ZORBAX Eclipse PAH ZORBAX HILIC Plus ZORBAX

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

Evaporative Light Scattering Detector (ELSD)

Evaporative Light Scattering Detector (ELSD) BÜCHI Labortechnik AG Evaporative Light Scattering Detector (ELSD) Martin Verstegen ELSD 3300 page 1 Overview of Common HPLC Detectors 1. UV/Vis 2. RI 3. Fluorescence 4. Mass Spectrometry 5. ELSD page

More information

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis [ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

Setting the Standard for ph Method Development

Setting the Standard for ph Method Development U.S. Patent o. 7, 56, 67 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible,

More information

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use Automating Gradient in Flash For Greater Productivity and Minimizing Solvent Use Melissa Wilcox, Rakesh Bose, Scott Anderson, Kathy Lawrence Grace Davison Discovery Sciences 251 Waukegan Rd. Deerfield

More information

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor luorophenyl Column With Raptor

More information

Acclaim HPLC and UHPLC Columns

Acclaim HPLC and UHPLC Columns Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical,

More information