An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint
|
|
- Miranda Cameron
- 5 years ago
- Views:
Transcription
1 An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar and nonpolar compounds. / of Inertsil ODS- retention for Hydrophobic compounds. Special new Sprint HG column hardware improves peak shape and efficiency.x0mm Sprint HG column is ideal for High-Throughput LC/MS Separations. Superior Inertness. Compatible with 00% aqueous eluents. -(CH ) CH Base Silica Physical Properties and Chemical Modification Particle Size: um Particle Shape: Spherical Specific Surface Area: 0m/g Pore Size: 00A Pore Volume:.0mL/g Purity: % Bonded Phase: Octadecyl groups Endcapped: Yes Carbon Load: 8.% Recommended ph Range: to. USP: L Guaranteed Theoretical Plate Numbers for 0 and 0mmm Column Length: 00,000/m QC Tests Employed: SEM, M, Ph, C, Schro, T, Py, Am, Ac, Cu, D, CP Perfectly Balanced Retention Our newly-developed chemical bonding technology allows Inertsil ODS Sprint to retain hydrophilic compounds (see peaks to, below) without excessive retention of non-polar compounds (see peaks to ). Hydrophobic compounds can be eluted quickly 6 um.6x0mm 6 System: GL00 HPLC system Eluent CH OH / H O = 80 / 0 Flow rate: Col.Temp.: Detection: ) Uracil ) Caffein ) Phenol ) n-butylbenzene ) o-terphenyl 6) n-amylbenzene ) Triphenylene.0 ml/min 0C nm Inertsil ODS- um.6x0mm
2 Sprint HG High Performance Column Hardware To help maximize the performance of Inertsil Sprint, GL Sciences developed a completely new column hardware design, called Sprint HG hardware. This hardware provides far less column dead-volume compared to other designs, resulting in higher theoretical number of plates and better peak shape. Sprint HG column hardware guarantees at least 00,000 plates/m for 0 and 0mm column lengths. The.X0mm Sprint HG column combines sharp peaks with fast elution time and is ideal for High-Throughput LC/MS Separations. New HG type hardware The current hardware EX type 0mm length column can be packed too!!! A) B) A) um.6x0mm B) Inertsil ODS- um.6x0mm Theoretical Plates Number of Peak No. =,9 Sharper Peaks!!! Theoretical Plates Number of Peak No. =,0 System: GL00 HPLC system Eluent: A) CH CN B)0.%H PO A:B=9: Flow rate:.0 ml/min Col. Temp.: 0 Detection: nm Injection Vol.: ml. Sudan (0.ug/mL). Sudan (0.ug/mL). Sudan (0.ug/mL). Sudan (0.ug/mL) Superior Inertness Inertsil Sprint is created by using a completely new bonding technique invented by GL Sciences. After bonding octadecyl silane (ODS) to highly purified base-silica gel, intensive end-capping is performed to eliminate residual silanols, creating an exceptionally inert column for reverse phase chromatography. Inertsil ODS Sprint phase shows excellent peak shapes for a wide range of polar analytes, including both basic compounds and acidic compounds, as shown in the chromatograms below. See the difference for yourself!!!
3 Pyridine Test for Base Deactivation Column Length:.6X0mm um Eluent CHOH / HO = 0 / 0 Flow Rate:.0 ml/min Col.Temp.: 0C Detector:: UVnm Sample Volume: ul Samples: ) Pyridine 0.09 mg/ml ) Phenol 0. mg/ml Symmetry C SunFire C XTerra MS C Atlantis dc Luna ODS() Gemini C Synergi MAX-RP Zorbax Eclipse XDB-C8
4 Aminopyridine Test for Base Deactivation Column Length:.6X0mm um Eluent CHOH / 0mM Phosphate Buffer (ph.6) 0:90 Flow Rate:.0 ml/min Col.Temp.: 0C Detector:: UVnm Sample Volume: ul Samples: ) -Aminopyridine 0.mg/mL ) -Aminopyridine.0mg/mL ) -Aminopyridine.0mg/mL Symmetry C8 0 0 SunFire C XTerra MS C Peak & are Compared to Peak, Peak & are absorbed. 0 0 Atlantis dc8 0 0 Luna ODS() 0 0 Gemini C Synergi MAX-RP 0 0 Zorbax Eclipse XDB-C8
5 Carboxylic Acid Test for Silanol Activity Column Length:.6X0mm um Mobile Phase: 0.% HPO(v/v) Flow Rate:.0 ml/min Col.Temp.: 0C Detector: UV0nm Sample Volume: ul Samples: ) Formic Acid 0. %(v/v) ) Acetic Acid 0. %(v/v) Symmetry C SunFire C XTerra MS C Formic acid is Atlantis dc8 Luna ODS() Gemini C Formic acid is Synergi MAX-RP Zorbax Eclipse XDB-C8
6 Test for Silica Purity Column Length:.6X0mm um Eluent CHOH / 0mM HPO (0/90, w:w) Flow Rate:.0 ml/min Col.Temp.: 0C Detector:: UVnm Sample Volume:.uL Samples: ) 0.0 mg/ml ) Caffeine 0. mg/ml Symmetry C8 0 0 Atlantis dc Luna ODS() SunFire C XTerra MS C8 0 0 Gemini C8 0 0 Synergi MAX-RP 0 0 Zorbax Eclipse XDB-C8
7 Compatible with 00% aqueous eluents Inertsil ODS Sprint is designed to have enhanced retention of polar compounds without an embedded polar group in the bonded phase ligand. To retain water-soluble organic compounds, the use of mobile phases that contain little or no organic modifier are sometimes needed. Under these highly aqueous conditions, conventional C8 columns often show sudden loss of retention, known as phase collapse. This phenomenon is caused by dewetting of the bonded phase inside the pores of the silica. The following data shows the results of a stop-flow test, which demonstrates Inertsil ODS Sprint s resistance to dewetting and phase collapse. Column:.6X0MM um Eluent: Water 00% Col.Temp.: 0C Flow rate:.0ml/min Detection: UVnm st analysis rd analysis ) Cytosine ) Uracil ) guanine ) thymine ) adenine Testing Procedure ) The st analysis was conducted after introducing the eluent for 0 minutes. ) Stop flow for minutes. ) The nd analysis was conducted after introducing the eluent for 0 minutes. ) Stop flow for minutes. ) The rd analysis was conducted after introducing the eluent for 0 minutes. st analysis,, rd analysis st analysis rd analysis,, st analysis rd analysis, Commercially Available ODS Column A Commercially Available ODS Column B Commercially Available ODS Embedded Column C Applications Analysis of Cold Medicine Analytical Condition System: GL-00 HPLC System Column: um 0X.6 mm I.D. Mobile Phase: A) Acetonitrile B) 0.% Phosphoric acid (A/B) = (0/90)-min-(0/90)-0min- (00/0) Flow Rate:.0 ml/min Column Temp: 0C Detector: UV at 0nm Sample Volume: 0uL (each 0mg/L) ) Potassium guaiacolsulfonate ) Acetaminophen ) Caffeine ) Ethenzamide ) Allyl isopropyl acetyl urea 6) Isopropylantipyrine ) Ibuprofen 6 Analysis of Food Colorants Analytical Condition System: GL-00 HPLC System Column: um 0X.6 mm I.D. Mobile Phase: A) Acetonitrile B) 0mM Phosphate buffer (ph6.9) (A/B) = (0/90)-0min-(/6) Flow Rate:.0 ml/min Column Temp.: 0C Detector: UV at 0nm Sample Volume: 0uL ) Acid Yellow No..6mg/L ) Acid Red No..8mg/L ) Acid Blue No..6mg/L ) Acid Red No.0.8mg/L ) Acid Yellow No..mg/L 6) Uranine.8mg/L ) Acid Red No.0.mg/L 8) Ponceau R.6mg/L 9) Ponceau SX.mg/L 0) Orange.mg/L ) Acid Green No..0mg/L ) Acid Blue No..0mg/L ) Acid Red No..mg/L ) Azul Blue VX.0mg/L ) Orange.6mg/L 6) Acid Red No.06.0mg/L Analysis of Catechins Analytical Condition System: GL-00 HPLC System Column: um 0X.6 mm I.D. Mobile Phase: A) Methanol B) 0mM Sodium dihydrogen phosphate (A/B) = (0/90)-0min-(0/0) Flow Rate:.0 ml/min Column Temp.: 0C Detector: UV at 80nm Sample Volume: 0uL (each mg/l) ) Gallocatechin (GC) )Epigallocatechin (EGC) ) Catechin (C) ) Epigallocatechin gallate (EGCg) ) Epicatechin (EC) 6) Gallocatechin gallate (GCg) ) Epicatechin gallate (ECg) 8) Catechin gallate (Cg) Analysis of Antibacterial Agents by LC/MS/MS Analytical Condition System: Symbiosis System Column: m 0x. mm I.D. Mobile Phase: A) Methanol B) 0.mM Ammonium acetate (A/B) = (0/0)-min-(90/0) Flow Rate: 0. ml/min Column Temp.: 0C Detector: API000 LC/MS/MS System ESI, Positive Sample Volume: 0uL (each 0ug/L) ) -NBA-AHD )-NBA-AOZ ) -NBA-SEM ) -NBA-AMOZ
8 Ordering Information ID(mm)..6 Length(mm) Cat.No. Cat.No Price * HG type hardware are used for all the sizes above. * End-fitting is Waters /6 type. * For other column sizes, please give us an enquiry. (Upon request) Cartridge Guard Column E Ordering Information Analytical Column I.D.mm Size Cartridge Guard Column E Guard Column I.D.mm Size Guard Column Length mm Size Cartridge Guard Column E (EA. / Set) Cat.No. Price Cat.No. Price. mm.0 mm 0 mm mm.0 mm 0 mm * When ordering, please specify the packing material and the particle size. * Only Waters /6 end-fitting type is compatible for our Cartridge Guard Column E. * Conventional Guard Columns and GL-Cart Guard Columns are also available. For more information, please feel free to contact us. * EX type hardware are used for all the Cartridge Guard Column E columns. The specification and the column type are subject to change without notice due to continual improvements. All brand names and product names are trademarks or registered trademarks of GL Sciences Inc. TM or are not described in this brochure. Cartridge Guard Column E Holder Set ( Cartridges & Holder) To find your local distributor, please visit to our website Simply select your country from the list and your local distributor Information will be displayed. ISO00: Save Energy and Resources!! Reduce Amount of Eluent with Smaller ID Inertsil Columns!!
State-of-the-art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%
More informationInertsil Technical Library
HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions
More informationInertsil ODS-EP Technical Information
Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can
More informationState - of - the -art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationAN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties
AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface
More informationInertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases
HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica
More informationInertSustainSwift C8
Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)
More informationMethod Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationThe Evolving HPLC Column Packings
The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationLC800. Smart HPLC. Until now UHPLC From now Smart HPLC
LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution
More informationACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationIon Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog
Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationCapital HPLC Columns and HPLC Cartridges. Optimal HPLC Range
Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil
More informationOverview Applications of NUCLEODUR HPLC Phases
verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-
More informationHPLC column C18 C8 PFP. SunShell. Core Shell Particle
HPLC column C8 C8 PFP SunShell Core Shell Particle ChromaNik Technologies Inc. SunShell is a core shell silica column made by ChromaNIk Technologies. The next generation to Core Shell particle Features
More informationTechnical Guide Thermo Scientific Syncronis HPLC Columns
Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one
More informationINERTSIL (GL Sciences)
Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationProntoSIL C18-EPS Reversed-Phase HPLC Columns
ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationComparison Guide to C18 Reversed Phase HPLC Columns
Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationACE Ultra Inert Base Deactivated HPLC Columns
ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-
More informationFast Separation of Vastly Different Compounds by Isocratic HPLC
Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite
More informationAdvantages of polymerbased. an alternative for ODS
Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:
More informationColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns
ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH
More informationHPLC column. Sunniest. C18, C18-HT, RP-AQUA, C8, PhE, PFP. ChromaNik Technologies Inc.
HPLC column Sunniest C8, C8-HT, RP-AQUA, C8, PhE, PFP Chromaik Technologies Inc. A ovel Bonding Technique (patent pending) The State of Art trifunctional silyl-reagent was developed as shown in Fig.. This
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationPacked columns for reversed-phase chromatography TSKgel ODS-100V and 100Z
Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic
More informationKromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography
Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial
More informationThe Selection of an HPLC Column October
The Selection of an HPLC Column 07. ctober Long-Term Collaboration + 30 Years of Experience GL Sciences Inc. HPLC Selection of an HPLC Column 3 Contents. How to Select an HPLC Column How to select your
More informationzorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax
Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column
More informationThermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time
Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:
More informationCompany Profile of GL Sciences Inc.
H PLC Sem ina r Introducing Inertsil HPLC Columns How to select HPLC best eluent How to select best column packing UHPLC and FastLC using u particles How to maintain best performance Company Profile of
More informationC18 Column. Care & Use Sheet
C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC
ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,
More informationHPLC UHPLC Columns. Dikma Technologies Inc.
Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate
More informationCOMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications
COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationRP C18 column with feature of a silanol group
RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise
More informationSTUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS
STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS Fang Xia, Jie Y. Cavanaugh, Uwe Neue, Jeffrey R. Mazzeo, Diane M. Diehl Waters Corporation, Milford, MA USA OVERVIEW- INTRODUCTION-
More informationNovel LC/MS-Compatible Stationary Phase with Polar Selectivity
Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationSilanol. Groups Liquid Chromatography
Abstract umber: 0-8P Study of Secondary Interaction Based on Residual lanol Groups for Reversed-Phase Liquid Chromatography II orikazu agae Ph.D, Kouji Yamamoto, Chiaki Kadota Chromaik Technologies Inc.
More informationH P L C C O L U M N S
H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil
More informationComparison of different aqueous mobile phase HPLC techniques
June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active
More informationOrosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.
Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationNew Product Update. HPLC Columns
New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna
More informationTracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability
Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass
More informationImprove Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application
Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationCLIPEUS - A Small Shield for a Big Job
CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,
More informationZirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More informationHypersil BDS Columns TG 01-05
TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide
More informationDilution(*) Chromatography
WA20264 Poster # 184, HPLC 2002, Montreal, 4-5 June 2002 At-Column Column-Dilution for Preparative Dilution(*) Chromatography Cecilia Mazza, Jie Cavanaugh, Ziling Lu,Tom Sirard,Tom Wheat and Uwe Neue Waters
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationN α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)
A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary
More information(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted
Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion
More informationHow proteins separate on reverse-phase HPLC
1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP
More informationGemini-NX Performance paired with Axia Technology
Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While
More informationOptical Isomer Separation Columns and Packing Materials
02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Inertsil Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More information8. Methods in Developing Mobile Phase Condition for C18 Column
I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely
More informationADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer
ADVANTAME SYNONYMS INS No. 969 Prepared at the 80 th JECFA (2015), published in FAO JECFA Monographs 17 (2015), superseding tentative specifications prepared at 77 th JECFA (2013). An ADI of 0-5 mg/kg
More informationsynergi Ultra-Performance HPLC The Concept Behind Synergi: Separate the Entire Polarity Spectrum Material Characteristics
Ultra-Performance HPLC Columns The Concept Behind : Separate the Entire Spectrum Much like a carpenter needs a good set of tools, we envisioned analytical chemists would appreciate a unique set of chromatography
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationZirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions
Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell
More information( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k
Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,
More informationWelcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster
Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm
More informationQUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3
Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long
More informationSmall Molecule Selectivity Sampler
Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles
More informationAPPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction
Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical
More informationPassion. Power. Productivity.
- - Passion. Power. Productivity. Acclaim Acclaim Acclaim PA/PA Acclaim A Acclaim Acclaim PA Acclaim Explosives rdering and Warranty Information In the U.S. All rders Including: Credit Card rders (VISA,
More informationODS-UG,HG,MG,SR columns
Column for reversed phase ODS-UG,HG,MG,SR columns Develosil ODS-HG Develosil ODS-UG Develosil ODS-MG Develosil ODS-SR The 2nd generation of Develosil series, very standard column This series is the column
More informationYour Reversed Phase Method
PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust
More informationTransferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM
Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM Eric S. Grumbach Thomas E. Wheat Chuck Phoebe Joe Arsenault Jeffrey R. Mazzeo Diane M. Diehl UPLC TECHNOLOGY
More informationHPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies
HPLC Method Development with Eclipse Plus: Standard Practices and New Columns Agilent Technologies What are Some Standard Method Development Practices?. Follow preferred method development scheme and do
More informationADVANTAME (TENTATIVE)
ADVANTAME (TENTATIVE) SYNONYMS INS No. 969 New tentative specifications prepared at the 77th JECFA (2013) and published in FAO JECFA Monographs 14 (2013). An ADI of 0-5 mg/kg body weight was established
More information