FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
|
|
- Robert Kelley
- 5 years ago
- Views:
Transcription
1 Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography
2 The Raptor luorophenyl Column With Raptor LC columns, Restek chemists became the first to combine the speed of.7 and 5 μm superficially porous particles (also known as SPP or core-shell particles) with the resolution of highly selective USLC technology, improving separations and speeding up analysis times with standard HPLC instruments. Raptor then evolved to bring that same improved speed, efficiency, and selectivity to UHPLC analyses by offering.8 μm particle columns. Learn more about Raptor LC columns at With the addition of Raptor luorophenyl columns, Restek further expanded the speed and reliability of Raptor column technology into the HILIC realm. Restek s Raptor luorophenyl phase offers chromatographers the ability to run in reversed-phase or HILIC mode for a variety of compounds. The Restek Raptor luorophenyl column is also amenable to LC-MS because it is extremely reliable and efficient with acidic mobile phases. Switch to a Raptor luorophenyl LC column for reliable performance in both reversed-phase and HILIC modes. Column Description: CH 3 Si CH 3 O Stationary Phase Category: Pentafluorophenyl propyl (L43) Ligand Type: luorophenyl Particle:.8 μm,.7 μm, or 5 μm superficially porous silica (SPP or core-shell ) Pore Size: 90 Å Surface Area: 5 m /g (.8 μm), 30 m /g (.7 μm), or 00 m /g (5 μm Recommended Usage: ph Range: Maximum Temperature: 80 C Maximum Pressure:,034 bar/5,000 psi* (.8 μm), 600 bar/8,700 psi (.7 μm); 400 bar/5,800 psi (5 μm) * or maximum lifetime, recommended maximum pressure for.8 μm particles is 830 bar/,000 psi. Properties: Capable of both reversed-phase and HILIC separations. Ideal for increasing sensitivity and selectivity in LC-MS analyses. Offers increased retention for charged bases. Switch to a Raptor luorophenyl LC column when: You observe limited retention and selectivity on a C8 for basic compounds. You need increased retention of hydrophilic compounds. Column Interaction Profile: Solute Retention Profile: Hydrophobic Dispersion H-Bonding Dipolar Acidic Polarizability Cation Exchange Defining Solute Interaction: Cation exchange Complementary Solute Interactions: Polarizability Dispersion Basic Target Analyte Structures: Nitrogen-containing Target Analyte unctionalities: Protonated amines Quaternary ammonium compounds Positively charged moieties Lewis bases
3 Raptor luorophenyl Columns: Rugged, Check Reproducible, Double Check. Of course, Raptor luorophenyl columns are rugged; that is to be expected. And, they are exceptionally reproducible as well. Reproducibility can be an issue for fluorinated phenyl phases, which is why we engineered all our columns for dependable performance. Lot to lot, column to column, and injection to injection, every Raptor luorophenyl column gives a consistent performance that you can count on: consider it done. igure : Raptor luorophenyl columns maintain efficiency in any dimension or particle size even at their maximum recommended operating pressures so you can run at high linear velocities with confidence. 0.0% 00.0% 90.0% % Efficiency vs. # of Injections at Maximum Pressure Raptor luorophenyl.7 µm.7 at µm 600 bar 30x.mm 50x.mm 00x.mm 50x.mm 30x3.0mm 80.0% 50x3.0mm 00x3.0mm 70.0% 50x3.0mm 30x4.6mm 60.0% 50x4.6mm 00x4.6mm 50.0% x4.6mm igure : Strict quality control ensures Raptor luorophenyl columns are exceptionally reproducible, so you get predictable performance from every column. Reliable, reproducible fluorophenyl column performance. igure 3: rom start to finish, Raptor luorophenyl columns provide accurate, reproducible results. Peaks tr (min) Precursor Ion Product Ion. 4-Methylimidazole (4-MEI) Peaks tr (min) Precursor Ion Product Ion Product Ion. Baccatin III Docetaxel Paclitaxel Lot Injection Injection 500 Lot Lot 3 Lot 4 Lot 5 Lot LC_BA035 Column: Raptor luorophenyl (cat.# 93955E); Dimensions: 50 mm x 3 mm ID, Particle Size: 5 µm; Temp.: 35 C; Sample: Diluent: Water; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (5% B),.00 (95% B),.0 (5% B), 3.50 (5% B); low: 0.8 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC LC_056 Column: Raptor luorophenyl (cat.# 939A5); Dimensions: 50 mm x. mm ID, Particle Size:.7 µm; Temp.: 35 C; Sample: Diluent: Acetonitrile; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (95% B),.00 (30% B),.0 (95% B), 3.50 (95% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. 3
4 More Separating Power than a C8 C8 columns work well for many compounds, but they just don t work for everything. Raptor luorophenyl columns can provide greater selectivity and retention for analytes that are not easily separated by C8 phase chemistry. or example, interest in vitamin D status is on the rise in clinical diagnostics, but accurate analysis is only possible if the epimeric forms of both vitamin D and D3 5-hydroxy metabolites can be distinguished. Typical reversed-phase C8 columns cannot separate these isobaric epimers, which differ in bioactivity, but the new Raptor luorophenyl column provides adequate chromatographic resolution so accurate results are generated and the proper diagnosis can be made. igure 4: Reversed-phase C8 columns do not have the right selectivity or retention mechanism to separate the epimers of vitamin D and D3 5-hydroxy metabolites. Epimers do not separate on a C8, even in a 4-minute analysis time.,, Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D3 40.5/ Epi-5-hydroxyvitamin D3 40.5/ Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D 43.5/ Epi-5-hydroxyvitamin D 43.5/ LC_C Column: Raptor ARC-8 (cat.# 934A); Dimensions: 00 mm x. mm ID, Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water:methanol (50:50); Conc.: 5-50 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (75% B), 4.00 (80% B),.00 (80% B),.0 (75% B); 4.00 (75% B); low: 0.5 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: HPLC. igure 5: Raptor luorophenyl columns have the selectivity and retention you need to quickly and easily separate compounds that coelute on a C8, such as the epimeric forms of vitamin D and D3 5-hydroxy metabolites. Raptor luorophenyl columns easily separate compounds that coelute on a C8. Raptor reproducibility lets you develop assays with confidence. Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D3 40.5/ Epi-5-hydroxyvitamin D3 40.5/ Lot Lot Conc. Peaks MRM tr (ng/ml). 5-Hydroxyvitamin D 43.5/ Epi-5-hydroxyvitamin D 43.5/ Lot LC_C LC_C0646 Column: Raptor luorophenyl (cat.# 939AE); Dimensions: 00 mm x 3 mm ID, Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water:methanol (50:50); Conc.: 5-50 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (75% B), 4.00 (85% B), 4.0 (00% B), 5.00 (00% B), 5.0 (75% B), 7.00 (75% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: HPLC. 4
5 Get the Power of HILIC and RP Modes in One LC Column HILIC chromatography is becoming the go-to solution for compounds that are difficult to retain on a C8. The Raptor luorophenyl column gives chromatographers the flexibility to evaluate compound retention in both reversed-phase and HILIC modes. The analysis of 4-methylimidazole (4-MEI), which is a byproduct of caramel coloring in foods and beverages, can be problematic by reversed-phase chromatography due to very limited retention. However, 4-MEI is well retained on a Raptor luorophenyl column and can easily be analyzed using HILIC mode and simple LC and LC-MS/MS compatible mobile phases. igure 6: Sometimes, adequate retention cannot be obtained with a C8. The Raptor luorophenyl column performs dependably in either HILIC or RP mode, so you can use the mode that is best for your analytes. Raptor luorophenyl columns give you the flexibility to work in both reversed-phase and HILIC modes. Peaks tr (min) Precursor Ion Product Ion. 4-Methylimidazole (4-MEI) HILIC retention of 4-MEI Lot Lot Lot LC_ Column: Raptor luorophenyl (cat.# 939A5); Dimensions: 50 mm x. mm ID; Particle Size:.7 µm; Temp.: 35 C; Sample: Diluent: Acetonitrile; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 min (95% B),.00 (30% B),.0 (95% B), 3.50 (95% B); low: 0.6 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. LC_
6 ast, Accurate Analysis of Basic Compounds Taxane drugs such as paclitaxel, docetaxel, and their precursor, baccatin III are early chemotherapy treatment options. Accurate analysis is critical because these drugs are used for many types of metastatic cancers. As shown here, the selectivity of the Raptor luorophenyl column provides excellent retention and resolution of these structurally similar compounds. Reliable results for these basic compounds can be obtained in fast analysis times using LC-MS/MS friendly solvents. igure 7: Raptor luorophenyl columns allow taxane drugs and other basic compounds to be separated quickly and effectively. Raptor luorophenyl columns have the retention needed for fast, accurate analysis of basic compounds. Peaks tr (min) Precursor Ion Product Ion Product Ion. Baccatin III Docetaxel Paclitaxel LC_BA035 Column: Raptor luorophenyl (cat.# 93955E); Dimensions: 50 mm x 3 mm ID, Particle Size: 5 µm; Temp.: 35 C; Sample: Diluent: Water; Conc.: 00 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: 0.% ormic acid in acetonitrile; Gradient (%B): 0.00 (5% B),.00 (95% B),.0 (5% B), 3.50 (5% B); low: 0.8 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. 6
7 Exceptional Selectivity for Clinical Analyses The analysis of normetanephrine and metanephrine provides another example of the power of Raptor luorophenyl columns for analyzing basic compounds. Accurately determining these metabolites of epinephrine/norepinephrine in plasma or urine is one of the best diagnostic tests for neuroendocrine tumors (pheochromocytomas). Normetanephrine and metanephrine are difficult to retain by typical C8 reversed-phase chromatography; however, the Raptor luorophenyl column provides a simple, fast chromatographic solution to this challenging assay. The Raptor luorophenyl column s unique combination of aromatic retention and cation exchange mechanisms are not provided by a C8 column and result in reliable, high-quality separations. igure 8: Rapid analysis of metanephrine and normetanephrine on a Raptor luorophenyl column. Peaks tr (min) Precursor Ion Product Ion Product Ion. Normetanephrine Metanephrine Lot Lot Lot LC_C LC_C064 Column: Raptor luorophenyl (cat.# 939A); Dimensions: 00 mm x. mm ID; Particle Size:.7 µm; Temp.: 30 C; Sample: Diluent: Water; Conc.: 0 ng/ml; Inj. Vol.: 5 µl; Mobile Phase: A: 0.% ormic acid in water; B: Methanol; Gradient (%B): 0.00 min (% B),.00 (40% B),.0 (% B), 6.00 (% B); low: 0.4 ml/min; Detector: MS/MS; Ion Mode: ESI+; Mode: MRM; Instrument: UHPLC. 7
8 Dependable Raptor luorophenyl Columns Give You the lexibility to Use Both HILIC and RP Modes Raptor luorophenyl LC Columns (USP L43) Raptor EXP Guard Cartridges for All Raptor Columns Hand-Tight itting No Tools Needed! Unidirectional Raptor EXP Guard Column Cartridge Holder Body Auto-adjusting Titanium Hybrid errule ZDV Connections!. mm cat.# 3.0 mm cat.# 4.6 mm cat.# Length.8 µm Columns 30 mm mm E 00 mm E 50 mm µm Columns 30 mm 939A3 939A3E 939A35 50 mm 939A5 939A5E 939A55 00 mm 939A 939AE 939A5 50 mm 939A6 939A6E 939A65 5 µm Columns 30 mm 93953E 50 mm E mm E mm E mm EXP Reusable ittings for HPLC & UHPLC for 0-3 fittings and /6" tubing Effortlessly achieve 8,700+ psi HPLC seals by hand! (Wrench tighten to 0,000+ psi.) Hybrid titanium/peek seal can be installed repeatedly without compromising your seal. Description qty. cat.# EXP Hand-Tight itting (Nut w/errule) ea EXP Hand-Tight itting (Nut w/errule) 0-pk EXP Hand-Tight Nut (w/o errule) ea Hybrid errule U.S. Patent No , EXP Holders U.S. Patent No , EXP Wrench U.S. Patent No. D Other U.S. and oreign Patents Pending. The EXP, ree-turn, and the Opti- prefix are registered trademarks of Optimize Technologies, Inc. Experience Selectivity Accelerated. Order the Raptor luorophenyl today at Protect your investment, extend the life of our already-rugged LC columns, and change guard column cartridges by hand without breaking fluid connections no tools needed! Great with any Raptor column to get ultimate protection from particulates and matrix contamination, especially when using dilute-and-shoot or other minimal sample preparation techniques. EXP Direct Connect Holder Description qty. cat.# EXP Direct Connect Holder for EXP Guard Cartridges (includes hex-head fitting & ferrules) ea Maximum holder pressure: 0,000 psi (,400 bar) Raptor EXP Guard Column Cartridges Particle 5 x. mm 5 x 3.0 mm 5 x 4.6 mm Description Size qty. cat.# cat.# cat.# Raptor luorophenyl EXP Guard Column Cartridge UHPLC 3-pk. 939U05 939U053 Raptor luorophenyl EXP Guard Column Cartridges.7 µm 3-pk. 939A05 939A A050 Raptor luorophenyl EXP Guard Column Cartridges 5 µm 3-pk ,034 bar/5,000 psi* (UHPLC), 600 bar/8,700 psi (.7 μm); 400 bar/5,800 psi (5 μm). * or maximum lifetime, recommended maximum pressure for.8 μm particles is 830 bar/,000 psi. Raptor SPP LC columns combine the speed of SPP with the resolution of USLC technology. Learn more at UltraShield UHPLC PreColumn ilter for.8 µm Raptor Columns Pair.8 µm Raptor columns with an UltraShield filter instead of a guard cartridge to protect against particulates, minimize extra column volume, and maximize UHPLC sample throughput when using SPE, SLE, or other extensive sample preparations. ilter Description Porosity qty. cat.# UltraShield UHPLC PreColumn ilter 0. µm frit ea pk pk. 58 Pure Chromatography Questions about this or any other Restek product? Contact us or your local Restek representative ( Restek patents and trademarks are the property of Restek Corporation. (See for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 08 Restek Corporation. All rights reserved. Printed in the U.S.A. Lit. Cat.# GNBR368B-UNV
FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.bgb-shop.com/raptor The Raptor luorophenyl Column With
More informationApply Force to Your LC Methods
Restek LC Apply orce to Your LC Methods Long-lasting and reproducible even with rapid cycling and elevated UHPLC pressures. ully scalable between HPLC and UHPLC easily transfer and optimize methods Premium
More informationDefinitive EtG/EtS LC-MS/MS Analysis:
Definitive / LC- Analysis: A Rugged 4-Min Method for High-Throughput Labs By Justin Steimling and Frances Carroll Abstract Methods for monitoring alcohol consumption biomarkers and are generally limited
More informationAnalysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method
Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method By Sharon Lupo and Frances Carroll Abstract The analysis of synthetic cannabinoids and their metabolites
More informationFast, Rugged Raptor Columns with Time-Tested Selectivity
Stationary Phase: Biphenyl Selectivity Accelerated Fast, Rugged Raptor Columns with Time-Tested Selectivity CH 3 Si CH 3 O Pure Chromatography www.bgb-info.com/raptor www.restek.com/raptor 1 The Raptor
More informationAhead of the Curve for Large, Multiclass Lists by Mass Spec
Stationary Phase: ARC-18 Selectivity Accelerated Ahead of the Curve for Large, Multiclass Lists by Mass Spec Si O Pure Chromatography www.bgb-info.com/raptor www.restek.com/raptor 1 The Raptor ARC-18 Column
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationSimultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS
Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS Richard Jack, Xiaodong Liu, Leo Wang, and Chris Pohl OT70806_E 08/13S 1 The world leader in serving science
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationThermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time
Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More information1.7µm Fortis UHPLC Columns
Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency
More informationEVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples
TN143 EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples This Chemistry Data Sheet provides guidelines for the extraction of quaternary
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More information1.7 m Fortis UHPLC Columns
Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationQuantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS
Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1
More informationYour Reversed Phase Method
PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationNext Generation of Phenyl Columns. Chromatography Products.
Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both
More informationMaximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System
Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System Application Note Authors Kevin McCann, Sameer Nene, Doug McIntyre, Edmond Neo, Dennis Nagtalon, and
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationSuccessfully Scaling and Transferring HPLC and UPLC Methods
Successfully Scaling and Transferring HPLC and UPLC Methods Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 6288 Fax: +358-9-5659 6282 Waters Finland Kutomotie 16 00380 Helsinki 2013 Waters Corporation
More informationSensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners
APPLICATION NOTE 21734 Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners Authors Aaron Lamb, Joanne Jones, Thermo Fisher Scientific, Runcorn, UK Keywords Environment, food
More informationJonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS
Rapid and Simultaneous Analysis of Urinary Catecholamines and Metanephrines Using Mixed-Mode SPE and Hydrophilic Interaction Chromatography (HILIC) for Clinical Research Jonathan P. Danaceau, Erin E. Chambers,
More informationAlternatives to Sub-2 µm UHPLC Columns
Alternatives to Sub-2 µm UHPLC Columns J. J. DeStefano, B. E. Boyes, S. Schuster, W. L. Miles, and J. J. Kirkland Advanced Materials Technology, Inc. 3521 Silverside Rd., Quillen Bld., Ste. 1-K Wilmington,
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationC18 Column. Care & Use Sheet
C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin
More informationBringing uhplc Performance to the Separation of Peptides
P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748
More informationLIQUID CHROMATOGRAPHY
LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationDo you need trouble-free speed? The NEW Chromolith HR
Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns
More informationImprove Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application
Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationPlasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS
Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 129 Infi nity LC, and 646 Triple Quadrupole LC/MS Application Note Clinical Research Authors Linda Côté and Christophe
More informationAcclaim Mixed-Mode WAX-1 Columns
User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,
More informationDo you need trouble-free speed? The NEW Chromolith HR
Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationIon Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog
Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationHPLC Winter Webinars Part 2: Sample Preparation for HPLC
HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do
More informationPhenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,
More informationQuantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS
Liquid Chromatography Mass Spectrometry SSI-LCMS-096 Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS LCMS-8045 Summary: A short, robust quantitative method for the analysis
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationHydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity
Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,
More informationHow proteins separate on reverse-phase HPLC
1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP
More informationMulti-mode Separations Using Zirconiabased Stationary Phases
Multi-mode Separations Using Zirconiabased Stationary Phases PITTC 2010 Dan owlan 1, Bingwen Yan 1, Clayton V. Mceff 1, R.A. Henry 2 1 ZirChrom Separations, Inc. 617 Pierce St., Anoka, M 55303 2 Independent
More informationChanging the way you think about HPLC
3521 Silverside Road Suite 1-K Quillen Building Wilmington, DE 19810 USA info@advanced-materials-tech.com Changing the way you think about HPLC Changing the way you think about HPLC New 5-micron HALO-5
More information+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid
PO-CON1751E Quantitation of plasma metanephrine and normetanephrine by derivatization using an integrated LC-MS/MS analyzer equipped with fully-automated sample preparation device ASMS 2017 ThP-099 Atsuhiko
More informationQuantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.
Quantitative analysis of small molecules in biological samples 100 Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB % 0 300 500 700 900 1100 1300 1500 1700 m/z Class Overview Introduction
More informationMethod Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationHPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment
HPLC & LC-MS Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment 2010 Innovation Seminar Series Supelco, Div. of Sigma-Aldrich Overview of Presentation Chromatographer
More informationviridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis
[ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)
More informationMixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma
Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma Ken Meadows, Thermo Fisher Scientific, Runcorn, UK Application Note 20789 Key Words
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationBasic Principles for Purification Using Supercritical Fluid Chromatography
Basic Principles for Purification Using Supercritical Fluid Chromatography Jo-Ann M. Jablonski, Christopher J. Hudalla, Kenneth J. Fountain, Steven M. Collier, and Damian Morrison Waters Corporation, Milford,
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationRoutine MS Detection for USP Chromatographic Methods
Daniel S. Root, Thomas E. Wheat, and Patricia McConville Waters Corporation, Milford, MA, USA APPLICATION BENEFITS This approach enables mass spectral analysis of peaks directly from unmodified USP HPLC
More informationACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,
More informationLC Column Troubleshooting. Do you have an equivalent column for my LC column?
LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there
More informationExtraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis
Application Note AN89.V.1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Page 1 Extraction of Methylmalonic Acid from Serum Using ISOLUTE SAX Prior to LC-MS/MS Analysis Sample Preparation
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationP R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns
P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns
More informationTechnical Guide Thermo Scientific Syncronis HPLC Columns
Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one
More informationFast Separation of Vastly Different Compounds by Isocratic HPLC
Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite
More informationA Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone
A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone Mia Summers and Kenneth J. Fountain Waters Corporation, 34 Maple St.,
More informationSmall Molecule Selectivity Sampler
Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles
More informationAn Introduction to Liquid Chromatography
An Introduction to Liquid Chromatography Brian A. Rappold Scientific Director Essential Testing (Collinsville, IL) Financial Disclosures: Grant/Research Support: None Salary/Consultant Fees: Essential
More informationHigh-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research
PO-CON1655E High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research ASMS 2016 MP-079 Atsuhiko TOYAMA 1, Kumie SATOU 2, Yuki NAKAMURA 2, Ichiro
More informationA Look at Agilent HPLC Columns Choices
A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle
More informationUPLC Method Development and Validation
UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy
More informationStreamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System
Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System Margaret Maziarz, Sean M. McCarthy, Michael D. Jones, and Warren B. Potts Waters Corporation, Milford, MA, USA A P
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More information[ CARE AND USE MANUAL ]
CONTENTS I. INTRODUCTION II. III. IV. GETTING STARTED a. Column Installation b. Column Equilibration c. Initial Column Efficiency Determination COLUMN USE a. Guard Columns b. Sample Preparation c. ph Range
More informationYun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION
Quantitation by High Resolution Mass Spectrometry: Using Target Enhancement and Tof-MRM to Achieve Femtogram-level On-column Sensitivity for Quantitation of Drugs in Human Plasma Yun W. Alelyunas, Mark
More informationAB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences
AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching s by Removal of Isobaric Interferences Differential Mobility Used as a Tool to Address Selectivity Challenges Adrian M. Taylor
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationTrends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles
Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles Richard A. Henry, Separation Technology Consultant On behalf of: Supelco/Sigma-Aldrich, Bellefonte, USA
More informationRapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry Application Note Food Authors Jianqiu Mi, Zhengxiang Zhang, Zhixu Zhang,
More informationNew Product Update. HPLC Columns
New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna
More informationFast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma
Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma Jon Bardsley 1, James Goldberg 2 1 Thermo Fisher Scientific, Runcorn, UK; 2 Thermo Fisher Scientific, West Palm Beach,
More information( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k
Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,
More informationAdvantages and Applications of Revolutionary Superficially Porous Particle Columns in Liquid Chromatography
WHITE PAPER Fast and Efficient HPLC Separations With Superficially Porous Particles Authors D. Guillarme, S. Fekete University of Geneva, University of Lausanne Analytical Pharmaceutical Chemistry Advantages
More informationLC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography
LC III: HPLC What is HPLC? Originally referred to as High-Pressure Liquid Chromatography Now more commonly called High Performance Liquid Chromatography In general: The instrument controlled version of
More informationPrep 150 LC System: Considerations for Analytical to Preparative Scaling
Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable
More informationEPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS
Application Note EPA Method 535 EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS API 3200 LC/MS/MS System Overview Described here is the
More informationKromasil Eternity Designed for long life. For use in HPLC and UHPLC
Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s
More informationAnalytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Clinical Research Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS Authors Yanan Yang 1, Victor Mandragon 2, and Peter Stone 1 1
More informationUptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules
Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim
More informationFluophase and Fluofix Columns
TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for
More informationfor Acclaim Trinity TM P1
for Acclaim Trinity TM P Product Manual for Acclaim TRINITY P Columns Page of 4 Product Manual for Acclaim Trinity TM P Columns 07556 Acclaim Trinity P, 3µm, 4.6 x 00mm 07556 Acclaim Trinity P, 3µm, 4.6
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More information