groups I and II cations, amines, divalent transition metals
|
|
- Mavis Margery Whitehead
- 5 years ago
- Views:
Transcription
1 IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger, 7µm metal complexes, organic acids Novosep A- polymer-based anion ph inorganic anions and oxyhalides; ideal for exchanger, 5µm separation of seven common anions plus three oxyhalide anions in one run AN polymer-based anion exchanger, 9µm Anion/S silica-based anion exchanger, 0µm Anion/R polymer-based anion exchanger, 0µm PRP -X00 polymer-based anion exchanger, 0µm Cation Exchange Columns Universal Cation silica-based cation exchanger, 7µm Universal Cation silica-based cation HR exchanger, µm PRP -X00 polymer-based cation exchanger, 0µm Organic Acid Columns PRP -X00 polymer-based sulfonated cation exchanger Anion Exclusion polymer-based cation exchanger, 0µm Specialty Columns Surfactant C8 silica-based reversedphase, 5µm Surfactant C8 silica-based reversedphase, 5µm EPA Methods Optimized for Suppressed or Non-Suppressed 00.0, Part A both , suppressed , 7.0,.0 ph inorganic anions, weak and strong acid ions, both 00 organic acids ph 5.5 inorganic anions non-suppressed 0 ph inorganic anions, weak and strong acid ions non-suppressed 0 ph inorganic anions, weak and strong acid ions non-suppressed 0 ph 7 ph 7 ph groups I and II cations, amines, divalent transition metals groups I and II cations, amines, divalent transition metals; smaller particle size for improved peak resolution groups I and II cations (separate runs), amines, lanthanides Page 00.7 both both 0 non-suppressed 0 ph simple aliphatic carboxylic acids and alcohols non-suppressed 0 ph organic acids, weak acid anions non-suppressed 04 ph 7 short chain anionic surfactants non-suppressed 05 ph 7 long chain or aromatic anionic surfactants non-suppressed 05 IC Guard Kits Cross Reference Kit includes holder and three guard cartridges. Guard Reference Table Guard Cartridge Type All-Guard Kit Part No. Brand Column Type Alltech Allsep, Allsep A- GA- 809 Novosep A- GA- 809 Anion/R, Anion/S GA- 809 Universal Cation GC- 709 Universal Cation HR GC- 5 Anion Exclusion GIE- 87 Transition Metal C8 GRP- 8 Surfactant/R GRP- 8 Surfactant C8, C8 GRP- 8 Dionex IonPac AS4A-SC, AS7, AS, GA- 809 AS, AS4, AS, AS7 IonPac CS, CS0, CS GC- 8 IonPac CS, CS4, CS5 GC- 709 IonPac NS GRP- 8 IonPac AS, AS5 GIE- 87 Guard Reference Table (continued) Guard Cartridge Type All-Guard Kit Part No. Brand Column Type Waters IC-Pak -A GA- 809 IC-Pak -M/D GC- 709 Ion Exclusion GIE- 87 Hamilton PRP -X00 GA- 809 PRP -X00 GC- 8 PRP -X00 GIE- 87 Misc. Sarasep ANIONSEP AN GA- 809 Bio-Rad, Aminex, HPX-87 GIE- 87 Interaction ION-0 GA- 809 Interaction ION-0 GC- 8 Interaction ORH-80 GIE- 87 Metrohm Metrosep GA- 809 more info Cartridges and holders can also be purchased separately. See specific phase pages for replacement cartridge ordering information. 98
2 Alltech Anion Columns Allsep Anion IC Columns Resolves fluoride away from the water dip Meets requirements for U.S. EPA Method 00.0 part A The Allsep Anion Column is compatible with common IC mobile phases: carbonate, bicarbonate, p-hydroxybenzoic acid, phthalic acid, succinic acid, and sodium octane sulfonate. Use this column for performing EPA Method 00.0 Part A Determination of Inorganic Anions in Water per U.S. EPA guidelines. Resolves Fluoride Away from the Water Dip 0. Fluoride. Chloride. Nitrite 4. Bromide 5. Nitrate. Phosphate 7. Sulfate Min. Allsep Anion, 7µm, 4. x 00mm (Part No. 507) 0.85mM NaHCO/0.9mM NaCO.mL/min Suppressed Allsep Anion Specifications Methacrylate based w/quaternary ammonium functional groups Particle Size: 7µm Mobile Phase Limits: ph 0, 0 00% organic modifier Allsep Anion Columns Packing i.d. x Length PEEK Part No. SS Part No. Allsep Anion 4. x 50mm x 00mm x 50mm related product Save money with IC All-Guard Kits on page 98. Kit includes one holder and three cartridges. 99
3 Alltech and Transgenomic Anion Columns Novosep A- Anion IC Columns Separates seven inorganic anions and three oxyhalide anions in a single run Meets the requirements of U.S. EPA Methods 00.0, 00., 7.0, and.0 The Novosep A- Anion Column is ideal for the separation of 0 inorganic anions by suppressor-based ion chromatography using U.S. EPA Method 00.. The column can also be used to determine inorganic anions in drinking water per U.S. EPA Method 00.0 and trace bromate in drinking water using U.S. EPA Methods 7.0 and.0. Anions in High Ionic Strength Water by EPA Method Fluoride. Chlorite. Bromate 4. Chloride 5. Nitrite-N. Bromide 7. Chlorate 8. Dichloroacetate 9. Nitrate-N 0. Phosphate-P. Sulfate Transgenomic IC Sep AN IC Column Separates anions with carbonate/bicarbonate and hydroxide mobile phases The Transgenomic IC Sep AN Column is compatible with both suppressor-based and non-suppressed detection. A variety of mobile phases including sodium carbonate/ bicarbonate, sodium hydroxide, and borate/gluconate may be used. Separation of Sulfite and Sulfate Fluoride. Chloride. Nitrite 4. Bromide 5. Nitrate. Phosphate 7. Sulfite 8. Sulfate Min Min. Novosep A- Anion, 5µm, 4.0 x 50mm (Part No. 540).mM NaHCO 0.8mL/min Suppressed Transgenomic IC Sep AN, 9µm, 4. x 50mm (Part No. 840).8mM NaHCO,.8mM NaCO.0mL/min Suppressed Novosep A- Anion Specifications Polyvinyl alcohol-based w/quaternary ammonium functional groups Particle Size: 5µm Mobile Phase Limits: ph, 0 00% organic modifier, 0% modifier is practical upper limit Transgenomic IC Sep AN Specifications Poly(styrene-divinylbenzene) alkyl dimethyl ethanol ammonium functional group Particle Size: 9µm Exchange Capacity: 0.05meq/g Mobile Phase Limits: ph, No organic solvents Novosep A- Anion Column Packing i.d. x Length PEEK Part No. Novosep A- 4.0 x 50mm 540 Guards for Novosep A- Anion Columns GA- Anion Cartridges 808 All-Guard Cartridge Holder* ea 800 more applications To view our complete searchable chromatogram database visit /chromdb/ Transgenomic IC Sep AN Columns Packing i.d. x Length Part No. AN 4. x 50mm 840 Choose a guard column or integral guard discs to protect your IC Sep Column. Transgenomic IC Sep Guards Guard Column, 50 x 4.mm ea 845 Guard Column Guard-Disc
4 Alltech Anion Columns Anion/S IC Columns Silica-based for symmetrical peak shapes Separates inorganic and organic anions The Anion/S Columns are best suited for routine separations of chloride, bromide, nitrate, and sulfate. Not suitable for fluoride analysis Min. EDTA and Other Anions 884. Nitrite. EDTA. Bromide 4. Nitrate Anion/S, 0µm, 4. x 00mm (Part No. 90).5mM Sulfuric Acid.0mL/min UV at 0nm Anion/R IC Columns Polymer-based for broad ph stability Separates seven common inorganic anions Because of their high ph stability, these columns are ideal for the separation of anions using high ph mobile phases such as p-hydroxybenzoate, sodium hydroxide, and sodium carbonate/bicarbonate. The larger dimension columns (50mm and 50mm) are suitable for a high-resolution separation of the seven common inorganic anions. 45 Weak Acid Anions 597. Borate (5ppm). Silicate (0ppm). Formate (0ppm) 4. Sulfide (0ppm) 5. Chloride (0ppm). Cyanide (0ppm) Anion/S Specifications Silica w/quaternary ammonium ion exchanger Particle Size: 0µm Exchange Capacity: 0.5meq/g Mobile Phase Limits: ph 5.5, 0 00% organic modifier Min. Anion/R, 0µm, 4. x 50mm (Part No. 909) 4mM Sodium Hydroxide/ 0.mM Sodium Benzoate.5mL/min Anion/S Columns Packing i.d. x Length PEEK Part No. SS Part No. Anion/S 4. x 00mm x 50mm 900 Anion/R Specifications Poly(styrene-divinylbenzene) Trimethylammonium Particle Size: 0µm Exchange Capacity: 0.9 ± 0.0meq/g Mobile Phase Limits: ph, 0 00% organic modifier related product Save money with IC All-Guard Kits on page 98. Kit includes one holder and three cartridges. Anion/R Columns Packing i.d. x Length PEEK Part No. SS Part No. Anion/R 4. x 00mm x 50mm x 00mm x 50mm 904 Guards for Anion/S and Anion/R Columns GA- Anion Cartridges 808 All-Guard Cartridge Holder* ea 800 0
5 Alltech Cation Columns Universal Cation and Universal Cation HR IC Columns Separate Groups I and II cations in one isocratic run Separate transition metals without post-column reaction New Universal Cation HR µm particle size for improved efficiency Compatible with a variety of mobile phases including complexing acids (citric acid, tartaric acid, oxalic acid), mineral acids (nitric acid, hydrochloric acid, sulfuric acid) and non-complexing organic acids (methanesulfonic acid). 4. Lithium (0.ppm). Sodium (.5ppm). Ammonium (.5ppm) 4. Potassium (.5ppm) Metal Ions Min Nickel (.5ppm). Zinc (.5ppm) 7. Cobalt (.5ppm) 8. Magnesium (.0ppm) 9. Calcium (.0ppm) Min. 4 5 Cesium and Strontium Universal Cation, 7µm, 4. x 00mm (Part No. 70) mm Methanesulfonic Acid.0mL/min Lithium (0.ppm). Sodium (0.90ppm). Ammonium (0.90ppm) 4. Potassium (.5ppm) 5. Cesium (0.8ppm). Magnesium (.ppm) 7. Calcium (.ppm) 8. Strontium (.ppm) Universal Cation, 7µm, 4. x 00mm (Part No. 70) mm Tartaric Acid/mM Oxalic Acid.0mL/min Universal Cation Specifications Silica coated with polybutadiene/maleic acid copolymer Particle Size: µm and 7µm, spherical Mobile Phase Limits: ph 7, 0 00% organic modifier 4 Rapid Analysis of Monovalent and Divalent Cations 5 0. Lithium. Sodium. Ammonium 4. Potassium 5. Magnesium. Calcium Universal Cation Columns Packing i.d. x Length PEEK Part No. SS Part No. 7µm 4. x 00mm µm HR 4. x 00mm x 5mm 09 technical assistance Contact Tech Support: Phone: (North America) contact.alltech@grace.com Online: Min. Universal Cation HR, µm, 7.0 x 5mm (Part No. 09) mm Methanesulfonic Acid.5mL/min more applications To view our complete searchable chromatogram database visit /chromdb/ Guards for Universal Cation Columns GC- Universal Cation 700 GC- Universal Cation HR 0 All-Guard Cartridge Holder* ea 800 related product Save money with IC All-Guard Kits on page 98. Kit includes one holder and three cartridges. 0
6 Hamilton Anion, Cation, and Organic Acid Columns PRP -X00 Anion Columns High ph stability makes this column ideal for the separation of weak anions. PRP TM -X00 provides excellent resolution for the seven most frequently analyzed inorganic anions. For non-suppressed analyses only. PRP -X00 Cation Analysis Columns For separation of the alkali metal and alkaline earth cations in separate runs. PRP -X00 Organic Acid Columns For separation of simple aliphatic carboxylic acids and alcohols. Inorganic anions are not retained. EDTA in Eye Drops 808. CuEDTA Hamilton PRP -X00 Specifications Trimethylammonium psdvb copolymer Particle Size: 0µm, spherical Exchange Capacity: 0.9meq/g Mobile Phase Limits: ph, 0 00% organic modifier Hamilton PRP -X00 Specifications Sulfonated psdvb copolymer Particle Size: 0µm, spherical Exchange Capacity: 0.5meq/g Mobile Phase Limits: ph, 0 00% organic modifier Hamilton PRP -X00 Specifications Sulfonated psdvb in H+ form Particle Size: µm and 7µm Mobile Phase Limits: ph, 0 00% organic modifier Alkali Metals 504. Lithium. Sodium. Ammonium 4. Potassium 5. Cesium Min. PRP -X00, 0µm, 4. x 50mm (Part No. 7944) 0.00N Sulfuric Acid ml/min UV at 54nm Min. PRP -X00, 0µm, 4. x 50mm (Part No. 7944) 0.004N HNO in 0% MeOH ml/min Hamilton PRP -X00 Columns Packing i.d. x Length Part No. PRP -X00. x 50mm x 50mm x 00mm x 50mm x 50mm 794 Hamilton PRP -X00 Columns Particle Size i.d. x Length Part No. PRP -X00 4. x 50mm x 50mm 7944 Hamilton PRP -X00 Guard Kits and Cartridges Guard Column Starter Kit ea PRP -X00, Holder, Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm Hamilton PRP -X00 Guard Kits and Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm Hamilton PRP -X00 Columns Particle Size i.d. x Length Part No. PRP -X00, 7µm 4. x 50mm x 50mm 7945 Hamilton PRP -X00 Guard Kits and Cartridges Replacement Guard Cartridges (Requires Hamilton Guard Holder) PRP -X00, 5 x.mm
7 Alltech Anion Exclusion Columns Separate organic acids and weak acid anions Polymer-based for broad ph stability Economical choice for small inorganics Anion Exclusion Columns separate organic acids and weakly ionized anions by an anion exclusion mechanism. Dilute mineral acids are the typical mobile phases for the separation. Acetonitrile may be used as an organic modifier to decrease the retention of hydrophobic compounds. Organic Acid Standards 07. Oxalic Acid. Maleic Acid. Malic Acid 4. Succinic Acid 5. Formic Acid. Acetic Acid Min. Anion Exclusion, 0µm, 7.5 x 00mm (Part No. 90).5mM Sulfuric Acid 0.4mL/min Anion Exclusion Specifications Highly sulfonated poly (styrene-divinylbenzene) cation exchanger Particle Size: 0µm Mobile Phase Limits: <0% acetonitrile, no methanol <5% isopropyl or ethyl alcohols Anion Exclusion Columns Packing i.d. x Length SS Part No. Anion Exclusion, 0µm 7.8 x 00mm x 00mm 900 Anion Exclusion All-Guard Cartridges Anion Exclusion GIE- 88 All-Guard Cartridge Holder* ea 800 related product Save money with IC All-Guard Kits on page 98. Kit includes one holder and three cartridges. 04
8 Alltech Surfactant Columns Surfactant/C IC Columns For non-suppressed analyses Silica-based for symmetrical peak shapes Choose Surfactant C8 for short chain anionic surfactants such as alkyl sulfates and alkyl sulfonates. Choose Surfactant C8 for long chain or aromatic surfactants such as xylene sulfonate and dodecyl benzene sulfonate. Alkyl Sulfates Octyl Sulfate. Decyl Sulfate. Dodecyl Sulfate Min. Surfactant C8, 5µm, 4. x 50mm (Part No. 907) 0.0g/L Ammonium Acetate in 40% Methanol.mL/min Surfactant/C Specifications Silica-based C8 or C8 Particle Size: 5µm Mobile Phase Limits: ph 7, 0 00% organic modifier Surfactant/C Columns Packing i.d. x Length SS Part No. C8, 5µm 4. x 50mm 909 C8, 5µm 4. x 50mm 909 Guards for Surfactant/C Columns GRP- Revised Phase 89 All-Guard Cartridge Holder* ea
IC Columns Introduction
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationIC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories
IC Section IC Columns..............................304-316 Introduction..............................305-306 Allsep Anion Columns...................... 307 Novosep Anion Columns.................... 308
More informationAlltech Ion Chromatography
Alltech Ion Chromatography See what's new in IC New! Novosep A-2 Anion Columns New! Amine & Organic Acid Standards New! Suppressors and Detection Systems Easily add IC capability to your HPLC Contact your
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationCation Exchange HPLC Columns
Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent
More informationAnion Exchange HPLC Columns
Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride
More informationDionex IonPac AS28-Fast-4µm column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column
More informationanion-exchange column
columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,
More informationcolumns IonPac AS17-C Anion Exchange Column
columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column
More informationcolumns IonPac AS22 Anion-Exchange Column
columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,
More informationcolumns IonPac SCS 1 Silica Cation Separator
columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly
More informationThermo Scientific Dionex IonPac AS23 Anion-Exchange Column
Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for
More informationcolumns IonPac AS18 Anion-Exchange Columns
columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,
More informationThermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationThermo Scientific. Anion-Exchange Column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is
More informationIC5000 Ion Chromatography System
IC000 Ion Chromatography System Quaternary gradient pumping and on-line eluent preparation to improve separations in complex samples In-line sample filtration to 0.8 µm to eliminate manual filtrations
More informationIon Analysis of Hydraulic Fluids in Fracking Process
Ion Analysis of Hydraulic Fluids in Fracking Process Presented by Jay Gandhi *, PhD Metrohm USA NEMC-2013 1 NEMC-2013 2 What we will cover today Background Hydraulic Fracking Ion Analysis Applications
More informationEfficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System
Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,
More informationRapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography
Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,
More informationThermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes
columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.
More informationINSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE
INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)
More informationSuperior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection
columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior
More informationData Pack. Ion Chromatography Methods. June 2009
Data Pack Ion Chromatography Methods June 2009 Table of Contents Introduction. 2 Ion Chromatography Methods List. 3 Inorganic Anions in Waters..7 Inorganic Anions in High Purity Waters..15 Inorganic Disinfection
More informationsuppressors Eluent Suppressors for Ion Chromatography
suppressors Eluent Suppressors for Ion Chromatography The Suppressor Advantage Dionex introduced suppression in 97, thereby bringing ion chromatography (IC) to the forefront of modern analytical techniques
More informationChapter 9. Chemical Names and Formulas
Chapter 9 Chemical Names and Formulas 9.1 - Naming Ions Monatomic ions: Single atom with a positive or negative charge resulting from the loss or gain of one or more valence electrons. - Cations: Groups
More informationSeCtiOn 7 [STOCK AND CUSTOM] Ion Chromatography Single and Multi-Element Standards
SeCtiOn 7 [STOCK AND CUSTOM] Ion Chromatography Single and Multi-Element Standards Your Science is Our Passion. Ion Chromatography Standards As with SPEX CertiPrep s Assurance Standards, every IC Standard
More informationConcentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)
columns and Trap Columns IonPac AG, AS, mm Eluent Source: EG Temperature: C IonPac AC ( mm) Flow Rate:. m/min Eluent: Potassium hydroxide, Inj. Volume: m, preconcentrated mm from to min, mm mm from min
More informationChromatography Theory and Applications
Chromatography Theory and Applications Chromatography Theory Overview Separation Modes Anion Exchange Chromatography Cation Exchange Chromatography Ion Exclusion Chromatography Ligand Exchange Chromatography
More informationIon Chromatography *
OpenStax-CNX module: m50231 1 Ion Chromatography * Brett Virgin-Downey Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 4.0 1 Introduction
More informationAnion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM
IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,
More information4. Ion chromatography (IC) 4.1. Educational aims and objectives
4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More informationExpanded capabilities in ammonium and amine detection
PRODUCT SPECIFICATIONS Thermo Scientifi c Dionex SC-CERS 500 Salt Converter-Cation Electrolytically Regenerated Suppressor Expanded capabilities in ammonium and amine detection Benefits Broadened ammonium
More informationcolumns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s
columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium
More informationHPLC. Columns and Resins. For a Complete Range of Applications
HPLC Columns and Resins For a Complete Range of Applications 0 HPLC COLUMNS AND RESINS HAMILTON Polymeric and Silica-Based Packings for a Complete Range of HPLC Separations To order products from this
More informationMagnetic Flowmeter Material Selection Guide
Magnetic Flowmeter Material Selection Guide www.sparlinginstruments.com Introduction The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter.
More informationIons and Ionic Compounds
Ions and Ionic Compounds Elements combine in a specific ratio to form compounds. Compounds can be categorized as ionic or covalent depending on the type of bond present within the compound. Ionic compounds
More informationNew On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography
New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure
More informationTheory of Ion Chromatography
Theory of Ion Chromatography The ideal method for analyzing anions, cations and polar substances is ion chromatography. It can be used to reliably quantify substances throughout a wide concentration range.
More informationThermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water
Thermo Scientific Dionex Ion Chromatography Solutions Global water safety bromate analysis in drinking water Safe drinking water public health assurance As a vital limited resource required for survival,
More informationThermo Scientific Dionex IonPac AS24A Anion-Exchange Column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS4A Anion-Exchange Column Product Specifications Thermo Scientific Dionex IonPac AS4A anion-exchange column is designed for the separation of haloacetic
More informationNomenclature for ionic compounds
Name: Nomenclature for ionic compounds Nomenclature is a system of naming. This worksheet presents a widely used system of nomenclature for ionic compounds. There are two types of metal cations with different
More informationUser Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.
User Manual IonPac NS2 Columns 065501 Revision 02 October 2015 For Research Use Only. Not for use in diagnostic procedures. Product Manual for IonPac NS2 Columns IonPac NS2, 5µm, 4x250mm Analytical Column
More informationThermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column
Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm
More informationHigh-Performance Chromatography Superior isocratic separation of
columns I o n P a c C S A C a t i o n - E x c h a n g e C o l u m n The IonPac CSA cation-exchange column provides fast analysis of mono- and divalent cations, ammonium, and aliphatic amines simultaneously
More informationOvercoming Challenging Matrices in Ion Chromatography
Overcoming Challenging Matrices in Ion Chromatography Presented by: Kirk Chassaniol Gulf Coast Conference 2014 October 14, 2014 Thermo Fisher Scientific NA IC Tech Support 1 The world leader in serving
More informationDetermination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System
Application Update 55 Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free System Introduction Hydrogen peroxide is an essential chemical in the fabrication
More informationIon Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin
Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the
More informationThermo Scientific Dionex IonPac AS26 Anion-Exchange Column
Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS column is a high-capacity, hydroxide-selective, anion-exchange column
More informationNew Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection
New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection Barbara Shao, Terri Christison, Fei Pang, Cathy Tanner, and Frank Hoefler, Thermo Fisher Scientific, Sunnyvale,
More informationINSTRUCTIONS ON EVERY AP EXAM:
Most Common Reaction Types: 1. Acid-base neutralization (both weak & strong) 2. Nonmetal and metal oxides with water 3. Active metals with water 4. Single replacement redox 5. Double replacement precipitation
More informationThe column program. The whole world of ion chromatography
The column program The whole world of ion chromatography 2 Metrohm the comprehensive solution 3 Metrohm has become a synonym for ion chromatography. For more than 30 years, Metrohm has been offering innovative
More informationThe column program. The whole world of ion chromatography
The column program The whole world of ion chromatography 2 Metrohm the comprehensive solution 3 Metrohm has become a synonym for ion chromatography. For more than 25 years, Metrohm has been offering innovative
More informationTHE CATION MUST ALWAYS BE WRITTEN FIRST
Name Honors Chemistry / / Binary Ionic Compounds An ionic compound is a compound that is formed between a metal and a non-metal. (Metalloids can also be used in ionic compounds, sometimes as cations and
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Thermo Scientific Acclaim Catalogue The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0) 0 0 Fax: + (0) Email: sales@hichrom.co.uk
More informationAP Chemistry Summer Assignment
AP Chemistry Summer Assignment AP Chemistry Students: This summer you are responsible for the following assignments: 1. You need to master the formulas, charges, and names of the common ions. On the second
More information500 SERIES CHEMICAL RESISTANCE GUIDE
500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250
More informationChapter 5: Nomenclature
Chem 1025 Prof George W.J. Kenney, Jr Introductory Chemistry, Zumdahl Decoste, 6th ed Last Update: 21July09 Chapter 5: Nomenclature These Notes are to SUPPLIMENT the Text, They do NOT Replace reading the
More informationIon Analysis of Hydraulic Fluids in Fracking Process
Ion Analysis of Hydraulic Fluids in Fracking Process Presented by Jay Gandhi *, PhD Metrohm USA Johnson Mathew USEPA R-6 Lab Houston TX 48th WCTOW - Vancouver Canada 1 Disclaimer working with USEPA *Reference
More informationCHEM 1105 S10 January 21, 2014
CHEM 1105 S10 January 21, 2014 Chapter 3: Compounds and Formulas Today: Types of compounds: Ionic vs. covalent Naming ionic compounds Naming binary covalent compounds (two elements only) Ionic Bonding
More informationUsing a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components
APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,
More informationSafety Manual > Incompatible Chemicals Partial Listing
Safety Manual > Incompatible Chemicals Partial Listing C. Incompatible Chemicals Partial Listing Chemical Incompatible Chemicals Acetic acid Chromic acid, nitric acid, permanganates, and peroxides Acetic
More information- Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS
63 POLYATOMIC IONS - Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS - Polyatomic ions form ionic compounds in the same way that single-element ions
More information- Use the STEM NAME of the element, then add "-ide" suffix
65 ANIONS 2 kinds Main-group nonmetals - Use the STEM NAME of the element, then add "-ide" suffix N : "nitride" ion P : "phosphide ion" O : "oxide ion" F : "fluoride ion" Polyatomic ions - Memorize list.(see
More informationThermo Scientific Dionex eluent suppressors for ion chromatography
PRODUCT SPECIFICATIONS Thermo Scientific Dionex eluent suppressors for ion chromatography Suppression was introduced in 97, thereby bringing ion chromatography (IC) to the forefront of modern analytical
More information- Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS
63 POLYATOMIC IONS - Some MOLECULES can gain or lose electrons to form CATIONS or ANIONS. These are called POLYATOMIC IONS - Polyatomic ions form ionic compounds in the same way that single-element ions
More informationAluminum Ammonium Sulfate 12 H2O Reagent ACS CAS No: Aluminum Nitrate Nonahydrate, Reagent ACS CAS No:
Gojira Fine Chemicals, LLC A World of Life Science Products - Just A Dragon's Breath Away 5386 Majestic Parkway - Suite 7 - Bedford Heights, OH 44146 www.gojirafc.com sales@goji rafc.com Reagents ACS Products
More informationWaters. Ion Chromatography
808q Waters Ion Chromatography Method Anion Analysis Using Hydroxide Eluent and Indirect Conductivity Detection and EPA Method B-1011 for Nitrite and Nitrate Using UV Detection 2000 Required Instrumentation:
More informationShow your work for all questions; answer all parts of all questions. No work = no credit.
Quiz: Ch 3 & 4 Name: Version M (32 pts) September 16, 2005 AP Chem Period: 1 2 3 4 Show your work for all questions; answer all parts of all questions. No work = no credit. 1. (10 pts) A compound contains
More informationCHEM 1364 Test #1 (Form A) Spring 2010 (Buckley)
Name CHEM 1364 Test #1 (Form A) Spring 2010 (Buckley) If you get stuck on one item, just go to the next and come back later. Point possibilities are indicated in parentheses to the right of each problem
More information1 Introduction. 1.1 Historical Perspective
1 1 Introduction 1.1 Historical Perspective Chromatography is the general term for a variety of physico-chemical separation techniques, all of which have in common the distribution of a component between
More informationInline sample preparation for the determination of anions in sodium hydroxide
APPLICATION UPDATE 72331 Inline sample preparation for the determination of anions in sodium hydroxide Authors Hua Yang and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Sample preparation,
More informationIon Chromatography. Introduction
Ion Chromatography Introduction Ion Chromatography (IC) was introduced in 1975 by Small, Stevens and Baumann as a new analytical method. Within a short period of time, ion chromatography developed from
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationUNIT 8: CHEMICAL FORMULAS AND NOMENCLATURE CHEMISTRY 215, DUFFEY
UNIT 8: CHEMICAL FORMULAS AND NOMENCLATURE CHEMISTRY 215, DUFFEY BIG IDEAS o 7.1 Ion formation - o 7.2 Ionic bonding - o 7.4 Metallic bonding - o 8.1 & 8.2 Covalent bonding - CHEMICAL BONDING o The purpose
More informationSPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods
How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine
More informationDetermination of trace anions in concentrated hydrofluoric acid
APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion
More informationHPLC COLUMNS. HPLC Columns & Bulk Resins THE MEASURE OF EXCELLENCE TM
HPLC COLUMNS & Bulk Resins THE MEASURE OF EXCELLENCE TM The Measure of Excellence Hamilton For nearly 0 years, Hamilton Company has been satisfying customer needs in the field of precision fluid measuring.
More informationWelcome to AP Chemistry!
Welcome to AP Chemistry! The first part of your summer assignment for AP Chemistry is quite simple (but not easy). You need to master the formulas, charges, and names of the common ions. During the first
More informationUnit 8: Ionic Compounds Notes and Practice
Name our Date What is bonding? Unit 8: Ionic Compounds Notes and Practice that hold atoms together to form compounds. Positive Ion Formation tend to valence e-. A charged ion is called a. Ex. Na o will
More information1. How many moles of hydrogen are needed to completely react with 2.00 moles of nitrogen?
Stoichiometry Mole-to-Mole 1. How many moles of hydrogen are needed to completely react with 2.00 moles of nitrogen? N 2 + H 2 NH 3 2. If 5.50 moles of calcium carbide (CaC 2 ) reacts with an excess of
More informationSeparation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC
TECHNICAL NOTE 122 Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC Authors Terri Christison and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA,
More informationExperiment #4. Chemical Nomenclature
Experiment #4. Chemical Nomenclature Many everyday and historically important chemical compounds have common names. For example, water is the common name for H 2 O, baking soda is the common name for NaHCO
More informationAnion Analysis of Ophthalmic Irrigation Solutions with the Shimadzu Prominence IC System Craig Young, PhD, Sr. Tech Support Specialist
High Performance Liquid Chromatography SSI HPLC 5 Anion Analysis of Ophthalmic Irrigation Solutions with the Shimadzu Prominence IC System Craig Young, PhD, Sr. Tech Support Specialist Introduction Ophthalmic
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationBig Idea: Matter & Atoms
Big Idea: Matter & Atoms Naming Ionic Compounds Naming Covalent Compounds Naming Acids Naming Hydrates The cation (positive ion) is written first Takes the same name as the element if only forms one charge
More informationDetermination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device
Determination of Bromate in Bottled Mineral Water Using the CRD 00 Carbonate Removal Device Thunyarat Phesatcha, Weerapong Worawirunwong, and Jeff Rohrer Thermo Fisher Scientific, Bangkok, Thailand; Thermo
More informationmau 200 ph min
mau ph - 6 8 TAKE A LOOK INSIDE TWIN Technology TWIN (Two-In-One ) Technology is what gives Gei its superior performance edge. During the final stage of silica manufacturing, a unique silica-organic layer
More informationName HONORS CHEMISTRY / / Oxide Reactions & Net Ionic Reactions
Name HONORS CHEMISTRY / / Oxide Reactions & Net Ionic Reactions The first type of reactions we will look at today are reactions between an oxide (a compound with oxygen as its anion) and water. There are
More informationHow to become a formulation hero
How to become a formulation hero Basics you will need to know these and a couple more! Write the symbols and oxidation numbers for these elements (hint: these only have one ox. number): 1. Lithium, sodium
More informationThe column program. The whole world of ion chromatography
The column program The whole world of ion chromatography 2 Metrohm the comprehensive solution 3 Metrohm has become a synonym for ion chromatography. For more than 25 years, Metrohm has been offering innovative
More informationsuppressors SRS -ULTRA Self-Regenerating Suppressor
suppressors SRS -ULTRA Self-Regenerating Suppressor The Self- Regenerating Suppressor utilizes AutoSuppression technology to enhance analyte conductivity while suppressing eluent conductivity. This results
More informationChem 105X Fri. Sept. 17, True 2. False. Dihydrogen monoxide is toxic. Today
Chem 105X Fri. Sept. 17, 2010 Today Written homework problem #1 Handed back #2 Due Monday in class Next week s lab 0% 0% 1) Formulas and names 2) Mixed nomenclature 3) Calculations: moles-atoms-molecules,
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationThermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column
chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo
More informationFormula of a Compound
Name Formula of a Compound 1. Useful only if it correctly represents the substance. 2. The composition is determined in chemical analysis. 3. The formula then is derived by atomic theory and chemical bonding
More informationAP CHEMISTRY. Summer Assignment
AP CHEMISTRY Summer Assignment Welcome to AP Chemistry! In order to have a smooth transition, students are expected to come in with some strong background knowledge. These are some of the things you need
More informationTernary Compounds. , to give the compound, NaNO 3, sodium nitrate.
Ternary Compounds Ternary Compounds Ternary compounds are those containing three different elements. (NaNO 3, NH 4 Cl, etc.). The naming of ternary compounds involves the memorization of several positive
More information