ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Size: px
Start display at page:

Download "ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability"

Transcription

1 ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm, µm and 0µm particles for UHPLC and HPLC Ultra-inert for maximum performance and reproducibility ACE UHPLC and HPLC s TM

2 ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability Ideal column choice for method development Exploit selectivity changes at low, intermediate and high ph Excellent column lifetime reduces the cost per analysis Specially designed for high and low ph mobile phases Designed for use with LC/MS-compatible buffers Recommended ph range.. No hysteresis problems when switching phs Ultra-Low Bleed for Improved LC/MS Compatibility Compatible with both MeOH and ACN Rapid column equilibration without memory effects Preparative dimensions available Reproducible scale up from analytical separations up to and 0µm particle sizes Exploit increased loading capacity of basic analytes at elevated ph Exploit Selectivity by Adjusting ph Application # 0 If ACE Excel SuperC8 does not outperform the column you are currently using, simply contact us for a full refund and keep the ACE Excel SuperC8 column (.mm -.6mm id) FREE OF CHARGE. ph 6 ph ph ph 7 0 ph ph ph 6 ph ph 7 ph 8 0 ph 9 ph 0 6 : ACE Excel µm SuperC8, 0 x.mm Sample: ) nizatidine ) salbutamol ) amiloride ) N-acetylprocainamide ) quinoxaline 6) methyl paraben 7) p-cresol 8) reserpine 9) piperine 0) toluene ) felodipine Temperature: 0 C Flow Rate: 0.ml/min Wavelength: nm Gradient: 00% B in 7 minutes Acidic Mobile Phase: A: 0mM ammonium formate in H O (ph.0) B: 0mM ammonium formate (ph.0) in 90:0 (v/v) MeCN/H O Basic Mobile Phase: A: 0.% NH (= 8mM) in H O (ph 0.7) B: 0.% NH (=8mM), ph 0.7 in 90:0 (v/v) MeCN/H O ph ph

3 ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability Encapsulated Bonding Technology (EBT ) for Improved Chromatography and Stability Traditional C8 Bonding ACE Excel SuperC8 with Encapsulated Bonding Technology (EBT ) C8 Endcapping group Unbonded silanol group C8 The unique Encapsulated Bonding Technology (EBT ) developed for ACE Excel SuperC8 columns dramatically increases ligand coverage of the silica surface and effectively eliminates the negative effect of unbonded silanol groups from separations. This higher ligand coverage results in improved inertness, chromatographic performance and stability. Many C8 bonded columns will exhibit ligand cleavage under acidic conditions, resulting in retention shifts and/or increased peak tailing. Under aggressive acidic conditions (see Figure ) ACE Excel SuperC8 is highly resistant to ligand cleavage, due to a combination of the Encapsulated Bonding Technology (EBT ) and ultra-inert ACE silica. Under basic conditions with LC/MS-compatible mobile phases (see Figure ), the Encapsulated Bonding Technology (EBT ) shields the ACE Excel SuperC8 surface from dissolution while maintaining excellent chromatographic performance. Traditional C8 bonded silica columns are prone to silica dissolution under these aggressive conditions, which can result in premature column deterioration. Figure - Excellent Acidic Stability at ph.8 Application # Acidic flow conditions : ACE Excel µm SuperC8, 0 x.mm Mobile Phase: 0:0 MeOH/0.% TFA in H O (ph.8) Temperature: 0 C Flow Rate: 0.0ml/min Figure - Excellent Basic Stability at ph 0.7 Application # Basic flow conditions : ACE Excel µm SuperC8, 0 x.6mm Mobile Phase: 0:0 ACN/0.% NH in H O (ph 0.7) Temperature: 0 C Flow Rate:.00ml/min Day k (phenanthrene) = 6.9 Day N0. (biphenyl) = 69,00pl/m Acidic Mobile Phase (ph.8) (continuous flow) >0,000 column volumes >,000 injections Basic Mobile Phase (ph 0.7) (continuous flow) >0,000 column volumes >,000 injections Day 0 k (phenanthrene) = 6.8 Day 0 N0. (biphenyl) = 68,700pl/m Evaluation conditions Sample: ) uracil ) dimethyl phthalate ) toluene ) biphenyl ) phenanthrene Mobile Phase: 70:0 MeOH:H O Temperature: C Flow Rate: 0.0ml/min Wavelength: nm Evaluation conditions Sample: ) uracil ) dimethyl phthalate ) toluene ) biphenyl ) phenanthrene Mobile Phase: 80:0 MeOH:H O Temperature: C Flow Rate:.00ml/min Wavelength: nm

4 ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability Comparison of Inertness at Intermediate ph Leading column brands in 0 x.mm LC/MS-compatible dimensions at ph.8 Silica, Hybrid and Superficially Porous particle technologies were compared Comparison of column efficiency for pyridine, a basic molecule Efficiency measured at % peak height to account for peak tailing effects Peak Efficiency Comparison Reproduced with kind permission of The Open University, UK. Application # ACE Excel SuperC8 Zorbax Eclipse.8 XDB C8,00pl/m 68,900pl/m Lower Tailing Agilent Poroshell.7 0 EC C8,900pl/m Waters XBridge. BEH C8 XP 0,800pl/m Waters Acquity.7 BEH C8 0,700pl/m Phenomenex Kinetex.6 C8 6,800pl/m Waters XBridge. C8,600pl/m Phenomenex Luna. C8() HST a,900pl/m Nucleoshell.7 RP8 a,00pl/m Phenomenex Kinetex.7 C8 0,700pl/m Zorbax Extend.8 C8 Thermo Accucore.6 C8 0,00pl/m 7,00pl/m Higher Tailing 0 0,000 0,000 60,000 80,000 00,000 N0.0 (pyridine) (plates/m) ACE Excel SuperC8 (fully porous ultra-inert silica) N 0.0 (pyr) = 68,900pl/m Waters ACQUITY.7 BEH C8 (hybrid particle) N 0.0 (pyr) = 0,700pl/m Phenomenex Kinetex.7 C8 (core-shell particle) N 0.0 (pyr) = 0,700pl/m Dimensions: 0 x.mm ( a 0 x.0mm) Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0:70 MeOH/0mM NH OAc in H O (ph.8) Flow Rate: 0.0ml/min Temperature: C Wavelength: nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. Conclusion: Significant differences in efficiency, peak shape and selectivity are seen when analyzing pyridine a basic molecule. Increased tailing and retention, combined with reduced efficiency, are indicative of undesirable secondary interactions between pyridine and silanol groups on the stationary phase surface. These interactions result in poor column reproducibility. ACE C8 columns have gained a well deserved reputation for providing excellent efficiency, peak shape and reproducibility. ACE Excel SuperC8 columns further build upon this proven reputation to provide the analyst with even better chromatographic performance across an extended range of ph conditions under LC/MS-compatible mobile phase conditions. Si-OH ACE Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC & HPLC Separations

5 ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability Comparison of Inertness at High ph LC/MS-compatible mobile phase at ph 0.7 Leading column brands in 0 x.6mm dimensions Comparison of column efficiency for pyridine, a basic molecule Efficiency measured at % peak height to account for peak tailing effects Peak Efficiency Comparison Reproduced with kind permission of The Open University, UK. Application # ACE Excel SuperC8 Phenomenex Gemini C8 Waters XBridge. BEH C8 Phenomenex Gemini-NX C8 Waters XSelect. CSH C8 ZORBAX Extend. C8 6,600pl/m,00pl/m,000pl/m,000pl/m 0,000pl/m,00pl/m 0 0,000 0,000 60,000 80,000 00,000 0,000 0,000 N0.0 (pyridine) (plates/m) ACE Excel SuperC8 N 0.0 (pyr) =,00pl/m Phenomenex Gemini C8 N 0.0 (pyr) = 6,600pl/m Waters XBridge. BEH C8 N 0.0 (pyr) =,00pl/m Phenomenex Gemini-NX C8 N 0.0 (pyr) =,000pl/m Waters XSelect. CSH C8 N 0.0 (pyr) =,000pl/m ZORBAX Extend. C8 N 0.0 (pyr) = 0,000pl/m Dimensions: 0 x.6mm Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0.% NH (=8mM), ph 0.7 in 60:0 (v/v) MeOH/H O Flow Rate:.00ml/min Temperature: C Wavelength: nm Comparative data may not be representative of all applications. Please see page for acknowledgment of trademarks. Conclusion: When analyzing a basic molecule (pyridine) at high ph, differences in efficiency, peak tailing and retention are seen. This suggests undesirable secondary interactions between the basic molecule and silanol groups on the stationary phase surface still remain. Further to the intermediate ph comparison (see page ), the ACE Excel SuperC8 again provides excellent peak shape and efficiency when analyzing a basic molecule (pyridine) at high ph, which indicates undesirable secondary interactions have been virtually eliminated. These undesirable interactions can also result in poor column reproducibility. Changing ph is a powerful tool to enable the selectivity to be optimized and sample impurities to be identified. ACE Excel SuperC8 columns are designed to provide excellent peak shape and lifetime under acidic, intermediate and high ph conditions with LC/MS-compatible buffers, and may additionally be used with mobile phases containing MeOH or ACN without suffering efficiency loss and/or extended equilibration times. Si-OH ACE Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC & HPLC Separations

6 ACE Excel SuperC8 Ultra-Inert UHPLC and HPLC s with Extended ph Stability Product Availability and Specifications Phase Functional Group Endcapped Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Maximum ph Range ACE Excel SuperC8 Octadecyl encapsulated Yes,,, a L USP Listing a ACE Excel SuperC8 is designed for use with LC/MS-compatible buffers. Further information is contained within ACE SuperC8 A Guide to Buffer Selection - please contact your distributor to request your FREE copy or visit To further extend UHPLC and HPLC column lifetimes, ACE pre-column filters are recommended for further details please contact MAC-MOD Analytical or visit For HPLC column connections up to 6000psi, PEEK fingertight fittings (p/n ACE-CC0) are recommended for further details please contact MAC-MOD Analytical or visit For UHPLC column connections up to 000psi, reuseable fittings (p/n EXL-CC0) are recommended for further details please contact MAC-MOD Analytical or visit ACE Excel µm SuperC8 UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm.mm EXL-0-00U EXL-0-00U EXL-0-0U EXL-0-00U EXL-0-70U EXL-0-00U EXL-0-0U EXL-0-0U.0mm EXL-0-00U EXL-0-00U EXL-0-0U EXL-0-00U EXL-0-70U EXL-0-00U EXL-0-0U EXL-0-0U.6mm EXL-0-06U EXL-0-06U EXL-0-6U EXL-0-06U EXL-0-76U EXL-0-06U EXL-0-6U EXL-0-6U PRICE $ $ $ $90 $66 $69 $70 $780 ACE Excel µm SuperC8 UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm 0mm.mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.0mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.6mm EXL--06U EXL--06U EXL--6U EXL--06U EXL--76U EXL--06U EXL--6U EXL--6U EXL--6U PRICE $0 $80 $9 $0 $70 $6 $67 $70 $80 ACE Excel µm SuperC8 UHPLC/HPLC s (supplied in dual compatible UHPLC/HPLC Excel hardware format with 000bar/000psi pressure limit) 0mm 0mm mm 0mm 7mm 00mm mm 0mm 0mm.mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.0mm EXL--00U EXL--00U EXL--0U EXL--00U EXL--70U EXL--00U EXL--0U EXL--0U EXL--0U.6mm EXL--06U EXL--06U EXL--6U EXL--06U EXL--76U EXL--06U EXL--6U EXL--6U EXL--6U PRICE $0 $60 $70 $90 $7 $60 $6 $690 $70 ACE µm SuperC8 Semi-Prep and Preparative HPLC s 0mm 7mm 00mm mm 0mm 0mm 7.7mm ACE--008 ACE--708 ACE--008 ACE--08 ACE--08 ACE mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0.mm ACE--00 ACE--70 ACE--00 ACE--0 ACE--0 ACE--0 Prices Available upon request. ACE 0µm SuperC8 Analytical, Semi-Prep and Preparative HPLC s (please enquire) UHPLC and HPLC s 0 Commons Court, Chadds Ford, PA 97 Phone: (800) -708 Fax: (60) 8-99 Website: info@mac-mod.com ACE is a registered trademark of Advanced Chromatography Technologies Limited. ACE Excel SuperC8, ACE Excel and EBT are trademarks of Advanced Chromatography Technologies Limited. Advanced Chromatography Technologies Limited acknowledges the registered and unregistered trademarks of Agilent Technologies Inc., Macherey-Nagel GmbH & Co. KG, Phenomenex Inc., Thermo Fisher Scientific and Waters Corporation and has no affiliation with any of these companies. 000Q/0/00-A00

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

ACE. Intelligent Solutions for Method Development. Method Development Kits ACE

ACE. Intelligent Solutions for Method Development. Method Development Kits ACE r: ffe e its ric k ty mn e p i tiv olu sam mn c c u le the col e d S an for ngle le si ab s a l i a a av O ACE Method Development Kits Intelligent Solutions for Method Development UHPLC and HPLC method

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs) A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

1.7µm Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

1.7µm Fortis C18 UHPLC Columns

1.7µm Fortis C18 UHPLC Columns Strength in Technology.7µm Fortis C8 Columns Ultra High Pressure Chromatography Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Wider Linear flow rate range .7µm Columns - 8m/g

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Successfully Scaling and Transferring HPLC and UPLC Methods

Successfully Scaling and Transferring HPLC and UPLC Methods Successfully Scaling and Transferring HPLC and UPLC Methods Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 6288 Fax: +358-9-5659 6282 Waters Finland Kutomotie 16 00380 Helsinki 2013 Waters Corporation

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

UPLC Method Development and Validation

UPLC Method Development and Validation UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

ANALYSIS OF BASIC COMPOUNDS

ANALYSIS OF BASIC COMPOUNDS COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Luna 2.5 µm C18(2)-HST Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency Table of Contents Part 1 Theory 1.1 Abstract...3 1.2 Introduction...3 Part 2 Set Up 2.1

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion HPLC Columns Agilent for Small Molecule InfinityLab Poroshell 0 ZORBAX Eclipse Plus ZORBAX Eclipse XDB ZORBAX 80Å StableBond ZORBAX 80Å Extend-C8 ZORBAX Bonus-RP ZORBAX Eclipse PAH ZORBAX HILIC Plus ZORBAX

More information

OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS

OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS 1997 Waters Corporation p. 1 980947 OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS T. Walter, P. Iraneta, and M. Capparella Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

CLIPEUS - A Small Shield for a Big Job

CLIPEUS - A Small Shield for a Big Job CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Kromasil Eternity Designed for long life

Kromasil Eternity Designed for long life Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

Kromasil Eternity Designed for long life

Kromasil Eternity Designed for long life Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which

More information

A C18 Silica Column With Exceptional Temperature and ph Stability

A C18 Silica Column With Exceptional Temperature and ph Stability A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies,

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,

More information

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core

More information

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

ACE ACE. HPLC and UHPLC Columns. Product Catalogue ACE HPLC and UHPLC Columns Product Catalogue ACE Ultra-Inert, Base Deactivated HPLC & UHPLC Columns ACE Ultra-Inert, Base Deactivated HPLC and ACE Excel UHPLC columns give you the choices you need to

More information

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

LC Column Troubleshooting. Do you have an equivalent column for my LC column? LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there

More information

High Resolution Fast LC

High Resolution Fast LC High Resolution Fast LC Easier Than You Think Rita Steed LC Columns Application Engineer May 9, 2013 What is High Resolution Fast LC? Maintain Resolution with Faster Run Time Increased Resolution with

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

ACE C18-PFP. A C18 bonded phase with unique selectivity. s Guaranteed reproducibility. lity. s Exceptional bonded phase stability

ACE C18-PFP. A C18 bonded phase with unique selectivity. s Guaranteed reproducibility. lity. s Exceptional bonded phase stability ACE CPFP A C bonded phase with unique selectivity & & & & & s Guaranteed reproducibility lity s Exceptional bonded phase stability s Hydrophobic and pentafluorophenyl mixed mode interaction HPLC Columns

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns Impact of Instrument Dispersion on Performance of HPLC Capillary Columns Wendy Roe, Richard A. Henry, and Hillel Brandes Supelco, Div. of Sigma-Aldrich Bellefonte, PA 16823 USA T413131 sigma-aldrich.com/analytical

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

SGE is excited to launch a new HPLC product line under the ProteCol brand.

SGE is excited to launch a new HPLC product line under the ProteCol brand. The Role of Pore Size in Reversed Phase HPLC SGE is excited to launch a new HPLC product line under the ProteCol brand. Fundamental to the new ProteCol line of columns is the continued focus on inert column

More information

Advanced HPLC Method Development Using Quality by Design

Advanced HPLC Method Development Using Quality by Design Advanced HPLC Method Development Using Quality by Design A comprehensive course in the systematic development of liquid chromatography separations using QbD principles COURSE HANDOUT: [SECTION 2] Separation

More information

A Look at Agilent HPLC Columns Choices

A Look at Agilent HPLC Columns Choices A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle

More information

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Prep 150 LC System: Considerations for Analytical to Preparative Scaling Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable

More information

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone Mia Summers and Kenneth J. Fountain Waters Corporation, 34 Maple St.,

More information

High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots

High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots Jason C. Link, William E. Barber, William Long, Anne Mack Agilent Technologies

More information

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Monica Dolci, Luisa Pereira, and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Abstract This poster summarizes the

More information