CLIPEUS - A Small Shield for a Big Job

Size: px
Start display at page:

Download "CLIPEUS - A Small Shield for a Big Job"

Transcription

1 CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience, chromatographers 2,000 years later still struggle when they work with inadequately shielded HPLC columns that are the by product of flawed end-capping technology. Higgins Analytical places a great deal of emphasis on effective silanol end-capping techniques. The bulky size and secondary chemical functionality of the end-capping moiety on TARGA (a large shield) HPLC columns and cartridges make them popular choices for researchers developing powerful LC/MS techniques or chromatographers doing routine analysis of difficult polar compounds. CLIPEUS - A Small Shield for a Big Job Phases C8, C18, Cyano, Phenyl Particle Sizes 4.5µm Pore Size 120Å Pore Volume 0.8mL/gm Surface Area 330m 2 /gm %Carbon C18 = 18% (w/w) Phase type Extremely well end-capped monofunctional phases Silica Class Type B Hardware Stainless steel and PEEK columns and cartridges: Nanobore columns Page 6 Microbore columns Page 6 Analytical and Narrowbore columns Page 7 Semi-Prep and Prep Columns Page 7 Cartridge columns - Analytical Page 8 Cartridge Columns - LC/MS Page 8 High Speed 10mm Semi-Prep cartridges Page 9 Prep Guard Cartridges Page 9 Analytical Guard Cartridges Page 9 Narrowbore guards and LC/MS Cartridges Page 9 Our CLIPEUS columns are based on the same ultra-pure, Type B silica gel we use for our TARGA products, but the end capping is done with the more traditional methodology employing TMS, a small molecule; hence CLIPEUS - a small shield. CLIPEUS columns have Higgins Analytical s characteristically high lot-to-lot reproducibility because our carefully controlled reaction of monofunctional silanes can be driven to completion in a reproducible manner. This unbuffered Pyridine and Phenol chromatogram illustrates the absence of any undesirable solute/silanol interaction on a CLIPEUS C18 HPLC Column. Applications The high purity base silica and thoroughly end capped bonded phases insure that CLIPEUS columns and cartridges will perform well in demanding situations where many other column brands fail. Even polar compounds elute as sharp and symmetrical peaks permitting surprisingly short columns to be used for high speed analysis. In addition to C8 and C18 phases, CLIPEUS columns are available with phenyl or cyano functionality. CLIPEUS C18 5µm 150x4.6mm 40% MeOH/water (unbuffered) 1mL/min, 25ºC, 254nm P/N HC185-CS1546

2 CLIPEUS CLIPEUS Offers a Wide Range of Hydrophobicity The highly pure silica backbone and the thorough end-capping process that are characteristics of CLIPEUS HPLC columns enable a wide choice of column selectivity without compromising chromatographic performance. Not only do the columns with relatively small cyano and phenyl functional groups perform as efficiently as do the longer chain C8 and C18 versions of CLIPEUS, they also produce symmetrical peaks for acidic and basic analytes. This is usually not the case for these types of columns from most HPLC column manufacturers. The four CLIPEUS chemistry offerings and the wide variety of column and cartridge formats, with internal diameters ranging more than two orders of magnitude, present a powerful selection to a chromatographer desiring to optimize a difficult separation or to maximize the speed of a high throughput application. Comparative Selectivity of CLIPEUS HPLC Columns Neutrals Test Mix NIST Test Mix CLIPEUS C18 150x4.6mm P/N HC185-CS1546 CLIPEUS C8 150x4.6mm P/N HC085-CS CLIPEUS Phenyl 150x4.6mm P/N HPHN5-CS CLIPEUS Cyano 150x4.6mm P/N HCNP5-CS1546 Carbamates and Urea Pesticides EPA 632A Industrial and Municipal Waste Water Column P/N HC185-CS Monuron 2. Propoxur 3. Carbaryl 4. Propham 5.Diuron 6. Linuron 7. Methiocarb 8. Mexacarbate 9. Chlorpropham 10. Barban 11. Neburon 50% MeCN/water, 1.5mL/min, 205nm 80% MeOH/Buffer, 1.5mL/min, 1. Thiourea 2. Phenol 3. Acetophenone 4. Nitrobenzene 5. Toluene 6. Napthalene No Metal Activity nor Residual Silanols The data in the chromatograms above clearly illustrate our purity and endcapping claims for the CLIPEUS 254nm Buffer: 20mM potassium phosphate 1. Uracil 2. Toluene 3. Ethylbenzene 4. Quinizarin 5. Amitriptyline family of HPLC columns. Quinizarin, a strong metal chelator, and amitriptyline, a very sensitive solute for residual silanols, both elute as very symmetrical peaks on all four column types making CLIPEUS a reliable choice for even difficult analytes.

3 Nanobore Columns CLIPEUS C8 5µm 150µm I.D. HC085-CN0315 $300 HC085-CN0515 $300 HC085-CN1015 $325 CLIPEUS C18 5µm 150µm I.D. HC185-CN0315 $300 HC185-CN0515 $300 HC185-CN1015 $325 CLIPEUS Cyano 5µm150µm I.D. HCNP5-CN0315 $315 HCNP5-CN0515 $315 HCNP5-CN1015 $365 CLIPEUS Phenyl 5µm150µm I.D. HPHN5-CN0315 $315 HPHN5-CN0515 $315 HPHN5-CN1015 $365 Microbore Columns CLIPEUS C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. HC085-CS0301 $290 HC085-CS0501 $300 HC085-CS1001 $325 HC085-CS1501 $350 HC085-CS2501 $380 HC085-CS03M5 $290 HC085-CS05M5 $300 HC085-CS10M5 $325 HC085-CS15M5 $350 HC085-CS03M3 $290 HC085-CS05M3 $300 HC085-CS10M3 $325 CLIPEUS C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. HC185-CS0301 $290 HC185-CS0501 $300 HC185-CS1001 $325 HC185-CS1501 $350 HC185-CS2501 $380 HC185-CS03M5 $290 HC185-CS05M5 $300 HC185-CS10M5 $325 HC185-CS15M5 $350 HC185-CS03M3 $290 HC185-CS05M3 $300 HC185-CS10M3 $325 CLIPEUS Cyano 5µm 1.0mm - 0.5mm - 0.3mm I.D. HCNP5-CS0301 $305 HCNP5-CS0501 $315 HCNP5-CS1001 $340 HCNP5-CS1501 $365 HCNP5-CS2501 $395 HCNP5-CS03M5$305 HCNP5-CS05M5$315 HCNP5-CS10M5 $340 HCNP5-CS15M5 $365 HCNP5-CS03M3$305 HCNP5-CS05M3$315 HCNP5-CS10M3 $340 CLIPEUS Phenyl 5µm 1.0mm - 0.5mm - 0.3mm I.D. HPHN5-CS0301 $305 HPHN5-CS0501 $315 HPHN5-CS1001 $340 HPHN5-CS1501 $365 HPHN5-CS2501 $395 HPHN5-CS03M5$305 HPHN5-CS05M5$315 HPHN5-CS10M5 $340 HPHN5-CS15M5 $365 HPHN5-CS03M3$305 HPHN5-CS05M3$315 HPHN5-CS10M3 $340

4 CLIPEUS Ordering Information Analytical Columns - Stainless Steel CLIPEUS C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns HC085-CS0346 $250 HC085-CS0546 $260 HC085-CS1046 $270 HC085-CS1546 $305 HC085-CS2546 $325 HC085-CS0330 $250 HC085-CS0530 $260 HC085-CS1030 $270 HC085-CS1530 $305 HC085-CS2530 $325 HC085-CS0321 $250 HC085-CS0521 $260 HC085-CS1021 $270 HC085-CS1521 $305 HC085-CS2521 $325 CLIPEUS C18 10µm 4.6mm I.D. s.s. columns HC181-CS0346 $230 HC181-CS0546 $240 HC181-CS1046 $250 HC181-CS1546 $275 HC181-CS2546 $300 CLIPEUS C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns HC185-CS0346 $250 HC185-CS0546 $260 HC185-CS1046 $270 HC185-CS1546 $305 HC185-CS2546 $325 HC185-CS0330 $250 HC185-CS0530 $260 HC185-CS1030 $270 HC185-CS1530 $305 HC185-CS2530 $325 HC185-CS0321 $250 HC185-CS0521 $260 HC185-CS1021 $270 HC185-CS1521 $305 HC185-CS2521 $325 CLIPEUS Cyano 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns HCNP5-CS0346 $260 HCNP5-CS0546 $270 HCNP5-CS1046 $280 HCNP5-CS1546 $305 HCNP5-CS2546 $325 HCNP5-CS0330 $260 HCNP5-CS0530 $270 HCNP5-CS1030 $280 HCNP5-CS1530 $305 HCNP5-CS2530 $325 HCNP5-CS0321 $260 HCNP5-CS0521 $270 HCNP5-CS1021 $280 HCNP5-CS1521 $305 HCNP5-CS2521 $325 CLIPEUS Phenyl 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns HPHN5-CS0346 $260 HPHN5-CS0546 $270 HPHN5-CS1046 $280 HPHN5-CS1546 $320 HPHN5-CS2546 $340 HPHN5-CS0330 $260 HPHN5-CS0530 $270 HPHN5-CS1030 $280 HPHN5-CS1530 $320 HPHN5-CS2530 $340 HPHN5-CS0321 $260 HPHN5-CS0521 $270 HPHN5-CS1021 $280 HPHN5-CS1521 $320 HPHN5-CS2521 $340 Semi-Prep and Prep Columns CLIPEUS C8 5µm CLIPEUS C18 10µm CLIPEUS C18 5µm 10 and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC085-CS0510 $440 HC085-CS1010 $550 HC085-CS1510 $800 HC085-CS2510$ x20mm 100x20mm 150x20mm 250x20mm HC085-CS0520$1120 HC085-CS1020 $1400 HC085-CS1520$1850 HC085-CS2520$ and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC181-CS0510 $300 HC181-CS1010 $370 HC181-CS1510 $530 HC181-CS2510 $670 50x20mm 100x20mm 150x20mm 250x20mm HC181-CS0520 $755 HC181-CS1020 $945 HC181-CS1520$1230 HC181-CS2520$ and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC185-CS0510 $440 HC185-CS1010 $550 HC185-CS1510 $800 HC185-CS2510$ x20mm 100x20mm 150x20mm 250x20mm HC185-CS0520$1120 HC185-CS1020 $1400 HC185-CS1520$1850 HC185-CS2520$2400

5 See Pages for information about holders required for these cartridge columns. HAICART - Stainless Steel Analytical Cartridge Columns CLIPEUS C8 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges HC085-CF0446 $270 HC085-CF0546 $285 HC085-CF1046 $270 HC085-CF0432 $270 HC085-CF0532 $285 HC085-CF1032 $270 CLIPEUS C18 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges HC185-CF0446 $270 HC185-CF0546 $285 HC185-CF1046 $270 HC185-CF0432 $270 HC185-CF0532 $285 HC185-CF1032 $270 CLIPEUS Cyano 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges HCNP5-CF0446 $285 HCNP5-CF0546 $300 HCNP5-CF1046 $295 HCNP5-CF0432$2850 HCNP5-CF0532 $300 HCNP5-CF1032 $295 CLIPEUS Phenyl 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges HPHN5-CF0446 $285 HPHN5-CF0546 $300 HPHN5-CF1046 $295 HPHN5-CF0432 $285 HPHN5-CF0532 $300 HPHN5-CF1032 $295 HAIPEEK - PEEK Analytical Cartridge Columns CLIPEUS C8 5µm CLIPEUS C18 5µm CLIPEUS Cyano 5µm CLIPEUS Phenyl 5µm HC085-CK0421 $250 HC085-CK0521 $255 HC185-CK0421 $250 HC185-CK0521 $255 HCNP5 -CK0421$265 HCNP5-CK0521 $270 HPHN5-CK0421 $265 HPHN5-CK0521 $270

6 CLIPEUS Ordering Information HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns CLIPEUS C8 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges HC085-CF0310 $250 HC085-CF0510 $295 HC085-CF1010 $370 CLIPEUS C18 10µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges HC181-CF0310 $170 HC181-CF0510 $200 HC181-CF1010 $250 CLIPEUS C18 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges HC185-CF0310 $250 HC185-CF0510 $295 HC185-CF1010 $370 CLIPEUS Cyano 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges HCNP5-CF0310 $265 HCNP5-CF0510 $310 HCNP5-CF1010 $385 CLIPEUS Phenyl 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges HPHN5-CF0310 $265 HPHN5-CF0510 $310 HPHN5-CF1010$385 HAISpeed20-20mm I.D. Prep Guard Cartridges CLIPEUS C18 10µm 20mm I.D. s.s. Prep Guard Cartridges 25x20mm 2/pkg HC181-CF0220 $275 HAICART GUARDS - Stainless Steel Guard Cartridges CLIPEUS C8 5µm 3.2mm I.D. s.s. Guard Cartridges HC108 $160 CLIPEUS C18 5µm CLIPEUS Cyano 5µm CLIPEUS Phenyl 5µm 3.2mm I.D. s.s. Guard Cartridges HC118 $ mm I.D. s.s. Guard Cartridges HC1CN $ mm I.D. s.s. Guard Cartridges HC1PH $170 HAIPEEK GUARDS - PEEK Guard Cartridges CLIPEUS C8 5µm 2.1mm I.D. PEEK Guard Cartridges HC085-CK0221 $165 CLIPEUS C18 5µm 2.1mm I.D. PEEK Guard Cartridges HC185-CK0221 $165 CLIPEUS Cyano 5µm 2.1mm I.D. PEEK Guard Cartridges HCNP5 -CK0221$175 CLIPEUS Phenyl 5µm 2.1mm I.D. PEEK Guard Cartridges HPHN5-CK0221 $175 Methylxanthines 1. Theobromine 2. Theophylline 3. Caffeine 4. Phenol CLIPEUS C18 150x4.6mm P/N CS1546-HC185 25% MeOH/water (unbuffered) 1mL/min, 30ºC, 254nm

Higgins Analytical. Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products

Higgins Analytical. Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products 1 2002-2004 Higgins Analytical Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products Higgins Analytical is a quality oriented company, dedicated to providing high performance

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S. Higgins Analytical

E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S. Higgins Analytical E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S Higgins Analytical 2008 C O N T E N T S HIGGINS ANALYTICAL 2-3 HPLC COLUMNS 24-29 CLIPEUS 4-5 MICROBORE COLUMNS 30-37 HAISIL 100 6-7

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

RP C18 column with feature of a silanol group

RP C18 column with feature of a silanol group RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

SGE is excited to launch a new HPLC product line under the ProteCol brand.

SGE is excited to launch a new HPLC product line under the ProteCol brand. The Role of Pore Size in Reversed Phase HPLC SGE is excited to launch a new HPLC product line under the ProteCol brand. Fundamental to the new ProteCol line of columns is the continued focus on inert column

More information

HPLC Column Classification

HPLC Column Classification HPLC Column Classification Introduction 1978 USP XIX Fourth supplement : L1 designation for C18 column 1980 USP XX : 7 columns were classified -Classified HPLC column to 56 descriptions -More than 220

More information

Silanol. Groups Liquid Chromatography

Silanol. Groups Liquid Chromatography Abstract umber: 0-8P Study of Secondary Interaction Based on Residual lanol Groups for Reversed-Phase Liquid Chromatography II orikazu agae Ph.D, Kouji Yamamoto, Chiaki Kadota Chromaik Technologies Inc.

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Agilent ZORBAX Column Selection Guide for HPLC Here it is your single

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

HPLC column C18 C8 PFP. SunShell. Core Shell Particle

HPLC column C18 C8 PFP. SunShell. Core Shell Particle HPLC column C8 C8 PFP SunShell Core Shell Particle ChromaNik Technologies Inc. SunShell is a core shell silica column made by ChromaNIk Technologies. The next generation to Core Shell particle Features

More information

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore

More information

Passion. Power. Productivity.

Passion. Power. Productivity. - - Passion. Power. Productivity. Acclaim Acclaim Acclaim PA/PA Acclaim A Acclaim Acclaim PA Acclaim Explosives rdering and Warranty Information In the U.S. All rders Including: Credit Card rders (VISA,

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

design: black sheep t: Reliable & reproducible performance every time - Guaranteed

design: black sheep t: Reliable & reproducible performance every time - Guaranteed design: black sheep t: 029 2049 0722 Reliable & reproducible performance every time - Guaranteed Accurate & quantitative data Affordable price Reproducibility Wide application range HPLC Column Requirements

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Changing the way you think about HPLC

Changing the way you think about HPLC 3521 Silverside Road Suite 1-K Quillen Building Wilmington, DE 19810 USA info@advanced-materials-tech.com Changing the way you think about HPLC Changing the way you think about HPLC New 5-micron HALO-5

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

Setting the Standard for ph Method Development

Setting the Standard for ph Method Development U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,

More information

E X P E RT M A N U F A C T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014

E X P E RT M A N U F A C T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014 E X P E RT M A N U FAC T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014 WO R L DW I D E AVA I L A B I L I T Y A N D S U P P O RT Higgins Analytical is a quality oriented company, dedicated

More information

Method 632. The Determination of Carbamate and Urea Pesticides in Municipal and Industrial Wastewater

Method 632. The Determination of Carbamate and Urea Pesticides in Municipal and Industrial Wastewater The Determination of Carbamate and Urea Pesticides in Municipal and Industrial Wastewater The Determination of Carbamate and Urea Pesticides in Municipal and Industrial Wastewater 1. SCOPE AND APPLICATION

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

LC Column Troubleshooting. Do you have an equivalent column for my LC column? LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there

More information

The Standard for ph Method Development

The Standard for ph Method Development The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

1.7µm Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs) A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary

More information

CHROMTECH - CHIRAL HPLC COLUMNS

CHROMTECH - CHIRAL HPLC COLUMNS CHIRAL HPLC COLUMNS These protein-based columns are suitable for several types of compounds; basic compounds with an extremely broad applicability, this column should be chosen first, if the analyte has

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

BETASIL Columns TG Å high purity silica

BETASIL Columns TG Å high purity silica BETASIL Columns TG0-0 00Å high purity silica Technical Guide BETASIL Columns Introduction 00Å high purity silica High surface area and phase loading Designed for small molecules Type B silica gives good

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

Separation of Structurally Similar Steroids on HALO C18 and PFP

Separation of Structurally Similar Steroids on HALO C18 and PFP Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

HPLC column. Sunniest. C18, C18-HT, RP-AQUA, C8, PhE, PFP. ChromaNik Technologies Inc.

HPLC column. Sunniest. C18, C18-HT, RP-AQUA, C8, PhE, PFP. ChromaNik Technologies Inc. HPLC column Sunniest C8, C8-HT, RP-AQUA, C8, PhE, PFP Chromaik Technologies Inc. A ovel Bonding Technique (patent pending) The State of Art trifunctional silyl-reagent was developed as shown in Fig.. This

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction Edouard S. P. Bouvier, Randy E. Meirowitz and Uwe D. Neue Waters Corporation, 34 Maple Street, Milford, MA 01757 USA Presented

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

Strength in Technology

Strength in Technology Strength in Technology Fortis C8 Excellent Peak Shapes Superb Quantitation ph Range - Fully Scalable 3,5,0μ C8 7% Fortis C8 is designed to provide characteristics which will aid in increased productivity

More information

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009 A Look at Column Choices Does one-size-fit-all? Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009 Seminar utline lica Surface Chemistry & Physical Characteristics ti lica Bonding

More information

HPLC at High Temperature and High ph with a New, Highly Stable Silica Column

HPLC at High Temperature and High ph with a New, Highly Stable Silica Column HPLC at High Temperature and High ph with a New, Highly Stable Silica Column W. Dale Felix, Stephanie J. Marin Brian A. Jones Selerity Technologies, Inc. 2484 W. Custer Road Salt Lake City, UT 84104 www.selerity.com

More information

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,

More information

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction

More information