Higgins Analytical. Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products

Size: px
Start display at page:

Download "Higgins Analytical. Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products"

Transcription

1 Higgins Analytical Quality Manufacturer of HPLC Columns, Cartridges and System Protection Products

2 Higgins Analytical is a quality oriented company, dedicated to providing high performance products, expert support, and rapid delivery to research and quality control laboratories Higgins Analytical on kromatografiakolonneja valmistava yritys, joka tarjoaa laadukkaita tuotteita, asiantuntevaa palvelua ja nopeat toimitukset tutkimus- ja Higgins Analytical est une société ayant pour objectif la qualité et de proposer des produits performants, un support expert, des livraisons rapides pour les laboratories de recherches et de contrôle qualité à travers le monde. I Higgins Analytical iyinkampani engusaziwayo kwezobuchwepheshe. Izinikele ekuthini ikhiqize umkhiqizo oseqophelweni eliphezulu. Izebenzisa uxhaso oluphambili ukukhipha imiphumela ecutshungwe kahle nangokushesha kanye nezindawo zokucubungula eziseqophelweni eliphezulu emhlabeni jikelele. Higgins Analytical ist eine Qualitäts orientierte Firma, welche sich der Lieferung von leistungsfähigen Produkten widmet, Kundenunterstützung durch Experten, sowie rasche Lieferung an Forschungs und Qualitätskontrolleinrichtungen Higgins Analytical es una compañia dedicada a poveer productos de óptima calidad, excelente rendimiento, experto soporte técnico y entrega immediata a los laboratorios de investigación y de control La Higgins Analytical é una societá orientata verso l alta qualitá, dedicata a fornire ai laboratori di ricerca e controllo qualitá nel mondo prodotti ad alto livello, supporto di esperti e Higgins Analities is n kwaliteits-georienteerde maatskappy wat toegewyd is om produkte van hoogstaande gehalte, kundige ondersteuning en snelle lewering van produkte vir navorsings-en gehalte-beheer laboratoria wereldwyd te voorsien.

3 Table of Contents 1 Higgins Analytical develops and manufactures a wide range of stainless steel and PEEK (polyetheretherketone) High Performance Liquid Chromatography (HPLC) columns and cartridges. These unique offerings address many needs of chromatographers desiring fast analysis times, extremely long column life, efficient system and column protection, and chemical inertness. Special application areas include: LC/MS Combinatorial Chemistry Proteomics QUALITY 2-3 CLIPEUS 4-9 HAISIL HAISIL HAISIL HL Column Switching Techniques Desalting In-line Filtration TARGA Guard Columns Products are supplied and supported worldwide by a network of responsive distributors. KROMASIL CARTRIDGE SYSTEMS HAIFILTER HAIGUARD Custom Products and Services 40 Acknowledgements 40 Ordering, Warranty, and Support 41

4 Total Quality Approach to all Aspects of Design, Manufacturing and Testing Each HPLC column and analytical cartridge from Higgins Analytical is evaluated by a computerized performance test prior to receiving a quality control approval. This testing protocol involves a highly accurate statistical moments determination of the column s performance characteristics. These sensitive peak shape and column efficiency measurements can only be made by computerized data logging methods. Product Traceability The test data for these serialized columns include sorbent properties and lot number as well as complete description of the test conditions. The instructions and other product information are detailed on the back of the test chromatogram. retrieve comprehensive quality control information and routinely apply it to our statistical process control activities. This commitment to quality manufacturing and comprehensive record keeping permits us to produce replacement Certificates of Analysis when requested by laboratories complying with their internal GLP needs. And, most importantly, we are able to assist customers during the lengthy process beginning with method development and optimization to validation and NDA filing by providing comprehensive serial number, manufacturing date, sorbent lot, and performance data for every column they ever purchased. Expert Manufacturing and State-of-the-Art Equipment Much of Higgins Analytical s staff has Comprehensive Record Keeping and Statistical Quality Control Raw digital test data is automatically archived for every column and analytical cartridge we manufacture. As a result, it is a simple matter for us to Higgins Analytical develops and manufactures a wide range of stainless steel and PEEK (polyetheretherketone) High Performance Liquid Chromatography (HPLC) columns and cartridges. These unique offerings address many needs of chromatographers desiring fast analysis times, efficient system and column protection, and chemical inertness. Special application areas include LC/MS, combinatorial chemistry, column switching techniques, in-line filtration, and guard column requirements. Products are supplied and supported worldwide by a network of responsive distributors. We are a quality-oriented chromatography company dedicated to providing performance products, expert support, and rapid delivery to research and quality control laboratories worldwide. been involved with the chemical separations business for over 20 years. By focusing this expertise exclusively on the separations consumables business, high quality products as well as high quality processes are assured. For example, our chemical engineer has developed solvent purification equipment and procedures that address all of the solvent requirements for production and quality control. Not only does this investment permit us to use the highest purity solvents available, it also eliminates much of the expensive and environment-polluting solvent disposal practice characteristically found in today s chemical industry.

5 Quality Design, Quality Manufacturing, Quality Control Computer Aided Drawings and Numerical Control Machinery Key to reinforcing our ability to provide the highest performance-to-price ratio products available in the separations consumables industry has been our investment in computer aided design (CAD) techequipment that minimize the health risks to us, and we have completely eliminated the use of ozone-depleting solvents. Since our plant is located on the edge of San Francisco Bay s picturesque wet-lands (home of the Thamnophis sirtalis tetrataenia - the endangered San Francisco gater snake, and venue for some of the best wind surfing in the world), we have taken extra measures to Our unique and highly automated column packing equipment is based on a closed, continuous flow system employing recoverable, unreactive, and safe fluids. And the best part about it is that it enables Higgins Analytical to manufacture a wide variety of HPLC columns with unrivaled efficiency. Concern for more than just the Green in our logo Our policy is to provide the highest performance available, so we put a tremendous amount of effort into assuring the quality of our products. We also place a great deal of attention on how we impact the environment. Just as our solvent purification practices have minimized our solvent consumption and waste disposal needs, the processes we have developed use materials and insure that our processes and products are environmentally sound. We are very proud of our compliance record with the local air quality, fire, and hazardous material regulatory agency requirements. Hardware Designed for Optimum Performance and Service Life High efficiencies and negligible extra-column effects are a certainty because Higgins Analytical columns use high quality PEEK and titanium frits that are only 0.75mm thick. Frit porosity also plays an important role in HPLC column design. Many manufacturers use 2µm porosity frits with their 5µm sorbents making high sensitivity work problematic since even the best particlesized 5µm materials can have 1% or more of sub 2µm material. These minute particles can pass through the frit and into the detector causing spiking and baseline noise. The column outlet fittings on Higgins Analytical columns have 0.5µm frits making them suitable for even the most sensitive detection Column labels are easy to read, impervious to solvent spills and temperature changes, and they do not dangle awkwardly from the column. Flow direction is clearly indicated.

6 CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience, chromatographers 2,000 years later still struggle when they work with inadequately shielded HPLC columns that are the by product of flawed end-capping technology. Higgins Analytical places a great deal of emphasis on effective silanol end-capping techniques. The bulky size and secondary chemical functionality of the end-capping moiety on TARGA (a large shield) HPLC columns and cartridges make them popular choices for researchers developing powerful LC/MS techniques or chromatographers doing routine analysis of difficult polar compounds. CLIPEUS - A Small Shield for a Big Job Phases C8, C18, Cyano, Phenyl Particle Sizes 4.5µm Pore Size 120Å Pore Volume 0.8mL/gm Surface Area 330m 2 /gm %Carbon C18 = 18% (w/w) Phase type Extremely well end-capped monofunctional phases Silica Class Type B Hardware Stainless steel and PEEK columns and cartridges: Nanobore columns Page 6 Microbore columns Page 6 Analytical and Narrowbore columns Page 7 Semi-Prep and Prep Columns Page 7 Cartridge columns - Analytical Page 8 Cartridge Columns - LC/MS Page 8 High Speed 10mm Semi-Prep cartridges Page 9 Prep Guard Cartridges Page 9 Analytical Guard Cartridges Page 9 Narrowbore guards and LC/MS Cartridges Page 9 Our CLIPEUS columns are based on the same ultra-pure, Type B silica gel we use for our TARGA products, but the end capping is done with the more traditional methodology employing TMS, a small molecule; hence CLIPEUS - a small shield. CLIPEUS columns have Higgins Analytical s characteristically high lot-to-lot reproducibility because our carefully controlled reaction of monofunctional silanes can be driven to completion in a reproducible manner. This unbuffered Pyridine and Phenol chromatogram illustrates the absence of any undesirable solute/silanol interaction on a CLIPEUS C18 HPLC Column. Applications The high purity base silica and thoroughly end capped bonded phases insure that CLIPEUS columns and cartridges will perform well in demanding situations where many other column brands fail. Even polar compounds elute as sharp and symmetrical peaks permitting surprisingly short columns to be used for high speed analysis. In addition to C8 and C18 phases, CLIPEUS columns are available with phenyl or cyano functionality. CLIPEUS C18 5µm 150x4.6mm 40% MeOH/water (unbuffered) 1mL/min, 25ºC, 254nm P/N HC185-CS1546

7 CLIPEUS CLIPEUS Offers a Wide Range of Hydrophobicity The highly pure silica backbone and the thorough end-capping process that are characteristics of CLIPEUS HPLC columns enable a wide choice of column selectivity without compromising chromatographic performance. Not only do the columns with relatively small cyano and phenyl functional groups perform as efficiently as do the longer chain C8 and C18 versions of CLIPEUS, they also produce symmetrical peaks for acidic and basic analytes. This is usually not the case for these types of columns from most HPLC column manufacturers. The four CLIPEUS chemistry offerings and the wide variety of column and cartridge formats, with internal diameters ranging more than two orders of magnitude, present a powerful selection to a chromatographer desiring to optimize a difficult separation or to maximize the speed of a high throughput application. Comparative Selectivity of CLIPEUS HPLC Columns Neutrals Test Mix NIST Test Mix CLIPEUS C18 150x4.6mm P/N HC185-CS1546 CLIPEUS C8 150x4.6mm P/N HC085-CS CLIPEUS Phenyl 150x4.6mm P/N HPHN5-CS CLIPEUS Cyano 150x4.6mm P/N HCNP5-CS1546 Carbamates and Urea Pesticides EPA 632A Industrial and Municipal Waste Water Column P/N HC185-CS Monuron 2. Propoxur 3. Carbaryl 4. Propham 5.Diuron 6. Linuron 7. Methiocarb 8. Mexacarbate 9. Chlorpropham 10. Barban 11. Neburon 50% MeCN/water, 1.5mL/min, 205nm 80% MeOH/Buffer, 1.5mL/min, 1. Thiourea 2. Phenol 3. Acetophenone 4. Nitrobenzene 5. Toluene 6. Napthalene No Metal Activity nor Residual Silanols The data in the chromatograms above clearly illustrate our purity and endcapping claims for the CLIPEUS 254nm Buffer: 20mM potassium phosphate 1. Uracil 2. Toluene 3. Ethylbenzene 4. Quinizarin 5. Amitriptyline family of HPLC columns. Quinizarin, a strong metal chelator, and amitriptyline, a very sensitive solute for residual silanols, both elute as very symmetrical peaks on all four column types making CLIPEUS a reliable choice for even difficult analytes.

8 Nanobore Columns CLIPEUS C8 5µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HC085-CN0315 $300 HC085-CN0515 $300 HC085-CN1015 $325 CLIPEUS C18 5µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HC185-CN0315 $300 HC185-CN0515 $300 HC185-CN1015 $325 CLIPEUS Cyano 5µm150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HCNP5-CN0315 $315 HCNP5-CN0515 $315 HCNP5-CN1015 $365 CLIPEUS Phenyl 5µm150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HPHN5-CN0315 $315 HPHN5-CN0515 $315 HPHN5-CN1015 $365 Microbore Columns CLIPEUS C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC085-CS0301 $290 HC085-CS0501 $300 HC085-CS1001 $325 HC085-CS1501 $350 HC085-CS2501 $380 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC085-CS03M5 $290 HC085-CS05M5 $300 HC085-CS10M5 $325 HC085-CS15M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HC085-CS03M3 $290 HC085-CS05M3 $300 HC085-CS10M3 $325 CLIPEUS C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC185-CS0301 $290 HC185-CS0501 $300 HC185-CS1001 $325 HC185-CS1501 $350 HC185-CS2501 $380 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC185-CS03M5 $290 HC185-CS05M5 $300 HC185-CS10M5 $325 HC185-CS15M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HC185-CS03M3 $290 HC185-CS05M3 $300 HC185-CS10M3 $325 CLIPEUS Cyano 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HCNP5-CS0301 $305 HCNP5-CS0501 $315 HCNP5-CS1001 $340 HCNP5-CS1501 $365 HCNP5-CS2501 $395 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HCNP5-CS03M5$305 HCNP5-CS05M5$315 HCNP5-CS10M5 $340 HCNP5-CS15M5 $365 30x0.3mm 50x0.3mm 100x0.3mm HCNP5-CS03M3$305 HCNP5-CS05M3$315 HCNP5-CS10M3 $340 CLIPEUS Phenyl 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HPHN5-CS0301 $305 HPHN5-CS0501 $315 HPHN5-CS1001 $340 HPHN5-CS1501 $365 HPHN5-CS2501 $395 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HPHN5-CS03M5$305 HPHN5-CS05M5$315 HPHN5-CS10M5 $340 HPHN5-CS15M5 $365 30x0.3mm 50x0.3mm 100x0.3mm HPHN5-CS03M3$305 HPHN5-CS05M3$315 HPHN5-CS10M3 $340

9 CLIPEUS Ordering Information Analytical Columns - Stainless Steel CLIPEUS C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC085-CS0346 $250 HC085-CS0546 $260 HC085-CS1046 $270 HC085-CS1546 $305 HC085-CS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC085-CS0330 $250 HC085-CS0530 $260 HC085-CS1030 $270 HC085-CS1530 $305 HC085-CS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC085-CS0321 $250 HC085-CS0521 $260 HC085-CS1021 $270 HC085-CS1521 $305 HC085-CS2521 $325 CLIPEUS C18 10µm 4.6mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC181-CS0346 $230 HC181-CS0546 $240 HC181-CS1046 $250 HC181-CS1546 $275 HC181-CS2546 $300 CLIPEUS C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC185-CS0346 $250 HC185-CS0546 $260 HC185-CS1046 $270 HC185-CS1546 $305 HC185-CS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC185-CS0330 $250 HC185-CS0530 $260 HC185-CS1030 $270 HC185-CS1530 $305 HC185-CS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC185-CS0321 $250 HC185-CS0521 $260 HC185-CS1021 $270 HC185-CS1521 $305 HC185-CS2521 $325 CLIPEUS Cyano 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HCNP5-CS0346 $260 HCNP5-CS0546 $270 HCNP5-CS1046 $280 HCNP5-CS1546 $305 HCNP5-CS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HCNP5-CS0330 $260 HCNP5-CS0530 $270 HCNP5-CS1030 $280 HCNP5-CS1530 $305 HCNP5-CS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HCNP5-CS0321 $260 HCNP5-CS0521 $270 HCNP5-CS1021 $280 HCNP5-CS1521 $305 HCNP5-CS2521 $325 CLIPEUS Phenyl 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HPHN5-CS0346 $260 HPHN5-CS0546 $270 HPHN5-CS1046 $280 HPHN5-CS1546 $320 HPHN5-CS2546 $340 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HPHN5-CS0330 $260 HPHN5-CS0530 $270 HPHN5-CS1030 $280 HPHN5-CS1530 $320 HPHN5-CS2530 $340 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HPHN5-CS0321 $260 HPHN5-CS0521 $270 HPHN5-CS1021 $280 HPHN5-CS1521 $320 HPHN5-CS2521 $340 Semi-Prep and Prep Columns CLIPEUS C8 5µm CLIPEUS C18 10µm CLIPEUS C18 5µm 10 and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC085-CS0510 $440 HC085-CS1010 $550 HC085-CS1510 $800 HC085-CS2510$ x20mm 100x20mm 150x20mm 250x20mm HC085-CS0520$1120 HC085-CS1020 $1400 HC085-CS1520$1850 HC085-CS2520$ and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC181-CS0510 $300 HC181-CS1010 $370 HC181-CS1510 $530 HC181-CS2510 $670 50x20mm 100x20mm 150x20mm 250x20mm HC181-CS0520 $755 HC181-CS1020 $945 HC181-CS1520$1230 HC181-CS2520$ and 20mm I.D. s.s. columns 50x10mm 100x10mm 150x10mm 250x10mm HC185-CS0510 $440 HC185-CS1010 $550 HC185-CS1510 $800 HC185-CS2510$ x20mm 100x20mm 150x20mm 250x20mm HC185-CS0520$1120 HC185-CS1020 $1400 HC185-CS1520$1850 HC185-CS2520$2400

10 See Pages for information about holders required for these cartridge columns. HAICART - Stainless Steel Analytical Cartridge Columns CLIPEUS C8 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC085-CF0446 $270 HC085-CF0546 $285 HC085-CF1046 $270 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC085-CF0432 $270 HC085-CF0532 $285 HC085-CF1032 $270 CLIPEUS C18 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC185-CF0446 $270 HC185-CF0546 $285 HC185-CF1046 $270 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC185-CF0432 $270 HC185-CF0532 $285 HC185-CF1032 $270 CLIPEUS Cyano 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HCNP5-CF0446 $285 HCNP5-CF0546 $300 HCNP5-CF1046 $295 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HCNP5-CF0432$2850 HCNP5-CF0532 $300 HCNP5-CF1032 $295 CLIPEUS Phenyl 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HPHN5-CF0446 $285 HPHN5-CF0546 $300 HPHN5-CF1046 $295 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HPHN5-CF0432 $285 HPHN5-CF0532 $300 HPHN5-CF1032 $295 HAIPEEK - PEEK Analytical Cartridge Columns CLIPEUS C8 5µm CLIPEUS C18 5µm CLIPEUS Cyano 5µm CLIPEUS Phenyl 5µm 2.1mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC085-CK0421 $250 HC085-CK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC185-CK0421 $250 HC185-CK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HCNP5 -CK0421$265 HCNP5-CK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HPHN5-CK0421 $265 HPHN5-CK0521 $270

11 CLIPEUS Ordering Information HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns CLIPEUS C8 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC085-CF0310 $250 HC085-CF0510 $295 HC085-CF1010 $370 CLIPEUS C18 10µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC181-CF0310 $170 HC181-CF0510 $200 HC181-CF1010 $250 CLIPEUS C18 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC185-CF0310 $250 HC185-CF0510 $295 HC185-CF1010 $370 CLIPEUS Cyano 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HCNP5-CF0310 $265 HCNP5-CF0510 $310 HCNP5-CF1010 $385 CLIPEUS Phenyl 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HPHN5-CF0310 $265 HPHN5-CF0510 $310 HPHN5-CF1010$385 HAISpeed20-20mm I.D. Prep Guard Cartridges CLIPEUS C18 10µm 20mm I.D. s.s. Prep Guard Cartridges 25x20mm 2/pkg HC181-CF0220 $275 HAICART GUARDS - Stainless Steel Guard Cartridges CLIPEUS C8 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HC108 $160 CLIPEUS C18 5µm CLIPEUS Cyano 5µm CLIPEUS Phenyl 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HC118 $ mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HC1CN $ mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HC1PH $170 HAIPEEK GUARDS - PEEK Guard Cartridges CLIPEUS C8 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC085-CK0221 $165 CLIPEUS C18 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC185-CK0221 $165 CLIPEUS Cyano 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HCNP5 -CK0221$175 CLIPEUS Phenyl 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HPHN5-CK0221 $175 Methylxanthines 1. Theobromine 2. Theophylline 3. Caffeine 4. Phenol CLIPEUS C18 150x4.6mm P/N CS1546-HC185 25% MeOH/water (unbuffered) 1mL/min, 30ºC, 254nm

12 HAISIL the Separations Work Horse The 100Å pore size, monomeric bonded phase, and very high performance make HAISIL 100 an ideal choice for separations ranging from small molecules such as carbamate Carbamate Pesticide Analysis on a 250x4.6mm HAISIL 100 Column pesticides and pharmaceutical drugs to synthetic oligonucleotides and small peptides. High efficiency, symmetrical peaks, and long column life is characteristic not only of the C8 and C18 reverse phase columns, but the normal phase silica columns as well. HAISIL The Workhorse Phases Silica, C8, and C18 Particle Sizes 3µm and 5µm Pore Size 100Å Pore Volume 0.5mL/gm Surface Area 190m 2 /gm %Carbon C8 = 7%(w/w), C18 = 12%(w/w) Phase type Monofunctional & fully endcapped Silica Class Type A Hardware Stainless steel and PEEK columns and cartridges: Nanobore columns Page 12 Microbore columns Page 12 Analytical and Narrowbore columns Page 13 Semi-Prep and Prep Columns Page 13 Cartridge columns - Analytical Page 14 Cartridge Columns - LC/MS Page 14 High Speed 10mm Semi-Prep cartridges Page 15 Prep Guard Cartridges Page 15 Analytical Guard Cartridges Page 15 Narrowbore guards and LC/MS Cartridges Page 15 Applications HAISIL 100 columns and cartridges are very good general purpose columns that are particularly well suited for small molecules and peptide applications. The HAISIL 100 column and cartridge efficiencies are unrivaled yet they represent one of the most economical product lines in the market today. In formats ranging from 0.17 to 20mm ID and from 20 to 250mm in length, HAISIL 100 is the sorbent we use to drive our competition crazy whenever challenged to an efficiency bake-off. 250x4.6mm HAISIL 100 5µm columns routinely produce around 100,000 plates/meter in our QC lab. Note that our column efficiencies are calculated by statistical moments - not an approximate peak-width method! While this performance is more than adequate for most requirements, HAISIL 100 3mm is also available. Typical Test Chromatogram for a 3µm 150x3.0mm HAISIL 100 Column The typical test chromatogram on the Certificate of Analysis pictured below illustrates that HAISIL 100 C18 3µm columns have the same near theoretical reduced plate height and perfect symmetry that is characteristic of their 5µm counterparts.

13 HAISIL Hormone Analogs LH-RH (Luteinizing Hormone - Releasing Hormone) Analogs are used for the inhibition of gonadal steroid production. An important application area is in the treatment of prostate cancer. Conditions HAISIL 100 C18 5µm 150x4.6mm Solvent A: Phosphoric acid, ammonium sulfate aqueous buffer Solvent B: Acetonitrile. Linear gradient at 1mL/min 254nm detection Analogs: Hormone Analogs A1: pglu-his-trp-ser-tyr-(d-ser(bu t ))-Leu-Arg-Pro- NHEt A2: pglu-his-trp-ser-tyr-d-ala-leu-arg-pro-nhet A3: pglu-his-trp-ser-tyr-d-leu-leu-arg-pro-nhet A4: pglu-his-trp-ser-tyr-d-ala-trp-leu-pro-nhet A5: pglu-his-trp-ser-tyr-d-trp-leu-arg-pro-nhet Economical Alternative for PICOTAG Analysis Our HAISIL 100 C18 columns have demonstrated superior resolution and life time for PICOTAG amino acid analysis when compared to considerably more expensive columns from other manufacturers. Besides good Alkaloids A Peruvian vine named Una de Gato (Uncaria tomentosa) and commonly referred to as Cat s Claw, has become a popular natural product source for herbal remedies. Enthusiasts claim the oxindole alkaloid extracts to be effective in the treatment of a wide range of digestive and circulatory diseases as well as Alkaloids from Cat s Claw analyzed on a HAISIL 100 C18 column P/N HS2546-HM185 other afflictions ranging from cancer to arthritis. Reputable providers of such phytochemical containing formulations carefully assay the alkaloid content of the extracts and formulations. The chromatogram above illustrates baseline resolution of Cat s Claw bark extracts containing isopteropodine, pteropodine, mitraphylline, isomitraphylline, ryncophylline and isorynchophylline. Kinetic Measurements in Disease Research Researchers at the University of California, Santa Cruz have recently published a novel HPLC method that yields baseline separation of per-deuterated and protonated lipoxygenases. The striking ability of a 250x4.6mm HAISIL 100 C18 column to resolve these two very similar compounds is enabling researchers to study large competitive kinetic isotope effects in Human 15-lipoxygenase catalysis. Protio/per-deutero ratio data obtained by this HPLC method agreed within experimental error of data obtained by ES-MS. The elucidation of these mechanisms is noteworthy because of the increasing role human lipoxygenases are playing in inflammatory diseases and cancer growth regulation. Enzymatic Reaction Mixtures of Human 15-lipoxygenase HAISIL 100 C18 250x4.6mm 74.9% MeOH, 25% water, 0.1%HoAC 1mL/min, 234nm P/N HS2546-HM185 PICOTAG Amino Acid Analysis linearity and column lifetime, the 150x4.6mm column yields very efficient amino acid analysis as shown in the chromatogram above (P/N HS1546-HM185). Why do HPLC columns plug up? A large percentage of HPLC columns die because the back pressure builds up. Most chromatographers (and many column manufacturers) believe this is because the inlet frit plugs up with particles. Actually, it is usually the packed-bed that becomes plugged by smaller than 1µm particles that pass through in-line filters and the 2µm inlet frit. 5µm Silica Gel Particle See pages µm Extra-Particle Flow Path

14 Nanobore Columns HAISIL 100 Silica 5µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HSIL5-HN0315 $300 HN0515-HSIL5 $300 HN1015-HSIL5 $350 HAISIL 100 C8 5µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HM085-HN0315 $300 HM085-HN0515 $300 HN1015-HM085 $350 HAISIL 100 C18 3µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HM183-HN0315 $325 HM183-HN0515 $325 HM183-HN1015 $375 HAISIL 100 C18 5µm 150µm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HM185-HN0315 $300 HM185-HN0515 $300 HM185-HN1015 $350 Microbore Columns HAISIL 100 Silica 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HSIL5-HS0301 $250 HSIL5-HS0501 $250 HSIL5-HS1001 $275 HSIL5-HS1501 $300 HSIL5-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm 250x0.5mm HSIL5-HS03M5 $250 HSIL5-HS05M5 $250 HSIL5-HS10M5 $275 HSIL5-HS15M5 $300 HSIL5-HS25M5 $325 30x0.3mm 50x0.3mm 100x0.3mm HSIL5-HS03M3 $250 HSIL5-HS05M3 $250 HSIL5-HS10M3 $275 HAISIL 100 C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HM085-HS0301 $250 HM085-HS0501 $250 HM085-HS1001 $275 HM085-HS1501 $300 HM085-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm 250x0.5mm HM085-HS03M5 $250 HM085-HS05M5 $250 HM085-HS10M5 $275 HM085-HS15M5 $300 HM085-HS25M5 $325 30x0.3mm 50x0.3mm 100x0.3mm HM085-HS03M3 $250 HM085-HS05M3 $250 HM085-HS10M3 $275 HAISIL 100 C18 3µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HM183-HS0301 $250 HM183-HS0501 $250 HM183-HS1001 $275 HM183-HS1501 $325 HM183-HS2501 $350 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm 250x0.5mm HM183-HS03M5 $250 HM183-HS05M5 $250 HM183-HS10M5 $275 HM183-HS15M5 $325 HM183-HS25M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HM183-HS03M3 $250 HM183-HS05M3 $250 HM183-HS10M3 $275 HAISIL 100 C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HM185-HS0301 $250 HM185-HS0501 $250 HM185-HS1001 $275 HM185-HS1501 $300 HM185-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm 250x0.5mm HM185-HS03M5 $250 HM185-HS05M5 $250 HM185-HS10M5 $275 HM185-HS15M5 $300 HM185-HS25M5 $325 30x0.3mm 50x0.3mm 100x0.3mm HM185-HS03M3 $250 HM185-HS05M3 $250 HM185-HS10M3 $275

15 HAISIL 100 Ordering Information 1 Analytical Columns - Stainless Steel HAISIL 100 Silica 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HSIL5-HS0346$220 HSIL5-HS0546$230 HSIL5-HS1046$235 HSIL5-HS1546$240 HSIL5-HS2546$250 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HSIL5-HS0330 $220 HSIL5-HS0530$230 HSIL5-HS1030 $235 HSIL5-HS1530$240 HSIL5-HS2530$250 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HSIL5-HS0321 $220 HSIL5-HS0521$230 HSIL5-HS1021 $235 HSIL5-HS1521$240 HSIL5-HS2521$250 HAISIL 100 C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HM085-HS0346 $220 HM085-HS0546 $230 HM085-HS1046 $235 HM085-HS1546 $240 HM085-HS2546 $250 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HM085-HS0330 $220 HM085-HS0530 $230 HM085-HS1030 $235 HM085-HS1530 $240 HM085-HS2530 $250 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HM085-HS0321 $220 HM085-HS0521 $230 HM085-HS1021 $235 HM085-HS1521 $240 HM085-HS2521 $250 HAISIL 100 C18 3µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 3µm SERIES 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HM183-HS0346 $230 HM183-HS0546 $240 HM183-HS1046 $250 HM183-HS1546 $280 HM183-HS2546 $300 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HM183-HS0330 $230 HM183-HS0530 $240 HM183-HS1030 $250 HM183-HS1530 $280 HM183-HS2530 $300 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HM183-HS0321 $230 HM183-HS0521 $240 HM183-HS1021 $250 HM183-HS1521 $280 HM183-HS2521 $300 HAISIL 100 C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HM185-HS0346 $220 HM185-HS0546 $230 HM185-HS1046 $235 HM185-HS1546 $240 HM185-HS2546 $250 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HM185-HS0330 $220 HM185-HS0530 $230 HM185-HS1030 $235 HM185-HS1530 $240 HM185-HS2530 $250 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HM185-HS0321 $220 HM185-HS0521 $230 HM185-HS1021 $235 HM185-HS1521 $240 HM185-HS2521 $250 Semi-Prep and Prep Columns HAISIL 100 Silica 5µm HAISIL 100 C8 5µm HAISIL 100 C18 5µm 10mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HSIL5-HS0510 $325 HSIL5-HS1010 $380 HSIL5-HS1510 $435 HSIL5-HS2510 $650 50x20mm 100x20mm 150x20mm 250x20mm HSIL5-HS0520 $800 HSIL5-HS1020 $825 HSIL5-HS1520 $1000 HSIL5-HS2520 $ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HM085-HS0510 $325 HM085-HS1010 $380 HM085-HS1510 $435 HM085-HS2510 $650 50x20mm 100x20mm 150x20mm 250x20mm HM085-HS0520 $800 HM085-HS1020 $825 HM085-HS1520$1000 HM085-HS2520$ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HM185-HS0510 $325 HM185-HS1010 $380 HM185-HS1510 $435 HM185-HS2510 $650 50x20mm 100x20mm 150x20mm 250x20mm HM185-HS0520 $800 HM185-HS1020 $825 HM185-HS1520$1000 HM185-HS2520$1500

16 See Pages for information about holders required for these cartridge columns. HAICART - Stainless Steel Analytical Cartridge Columns HAISIL 100 Silica 5µm HAISIL 100 C8 5µm mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HSIL5-HF0446 $240 HSIL5-HF0546 $245 HSIL5-HF1046 $220 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HSIL5-HF0432 $240 HSIL5-HF0532 $245 HSIL5-HF1032 $ mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HM085-HF0446 $240 HM085-HF0546 $245 HM085-HF1046 $220 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HM085-HF0432 $240 HM085-HF0532 $245 HM085-HF1032 $220 HAISIL 100 C18 5µm mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HM185-HF0446 $240 HM185-HF0546 $245 HM185-HF1046 $220 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HM185-HF0432 $240 HM185-HF0532 $245 HM185-HF1032 $220 HAIPEEK - PEEK Analytical Cartridge Columns HAISIL 100 Silica 5µm HAISIL 100 C8 5µm HAISIL 100 C18 5µm 2.1mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HSIL5-HK0421 $220 HSIL5-HK0521 $ mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HM085-HK0421 $220 HM085-HK0521 $ mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HM185-HK0421 $220 HM185-HK0521 $225 HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns HAISIL 100 Silica 5µm HAISIL 100 C8 5µm HAISIL 100 C18 5µm 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HSIL5-HF0310 $200 HSIL5-HF0510 $250 HSIL5-HF1010 $295 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HM085-HF0310 $200 HM085-HF0510 $250 HM085-HF1010 $295 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HM185-HF0310 $200 HM185-HF0510 $250 HM185-HF1010 $295

17 HAISIL 100 Ordering Information HAISpeed20-20mm I.D. Prep Guard Cartridges HAISIL 100 Silica 10µm HAISIL 100 C18 10µm 20mm I.D. s.s. Prep Guard Cartridges 25x20mm 2/pkg HSIL1-HF0220 $275 20mm I.D. s.s. Prep Guard Cartridges 25x20mm 2/pkg HM181-HF0220 $275 HAICART GUARDS - S.S. Guard Cartridges HAISIL 100 Silica 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HH1SI $145 HAISIL 100 C8 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HH108 $145 HAISIL 100 C18 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HH118 $ Å vs. 300Å Columns for Peptide Mapping The question of whether to use a 100Å or 300Å column for mapping usually divides peptide chromatographers into two groups. Rather than take sides, we have chosen to offer very efficient columns with both pore diameters to suit both camp's preferences. HAISIL 100 and HAISIL 300 columns are available in 20 to 250mm lengths and 0.15mm to 20mm internal diameters. HAIPEEK GUARDS - PEEK Guard Cartridges HAISIL 100 Silica 5µm 2.1mm I.D. PEEK Cartridges 20x2.1mm 5/pkg HSIL5-HK0221 $150 HAISIL 100 C8 5µm HAISIL 100 C18 5µm 2.1mm I.D. PEEK Cartridges 20x2.1mm 5/pkg HM085-HK0221 $ mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HM185 -HK0221$150 Tryptic Map of Transferrin on HAISIL x4.6mm P/N HS2546-HM185 HAICART (stainless steel) and HAIPEEK (PEEK) guard cartridges are compatible with Higgins Analytical HAIPEEK Guard Holders and the PE Brownlee NewGuard Holder. Tryptic Map of Transferrin on HAISIL x2.1mm P/N HS2521-HW185

18 HAISIL 300 Wide Pore Columns Higgins Analytical's HAISIL 300 C4, C8 and C18 columns are popular alternatives for biomolecule analysis where larger pore diameters often enhance separations. High efficiencies, long column life, and extremely symmetrical peaks are characteristics of HAISIL 300 columns that range in size of 20mm - 250mm in length. 150µm - 20mm Internal Diameters Higgins Analytical's reputation for manufacturing efficient and robust columns now ranges from 150µm to 20mm internal diameter. The sub 1mm ALGO Series, meaning "a sharp needle," appropriately describes the peaks obtained from HAISIL for Biomolecules Phases C4, C8, and C18 Particle Sizes 5 and 10µm Pore Size 300Å Pore Volume 0.7mL/gm Surface Area 80m 2 /gm %Carbon (w/w) C4 = 3%, C8 = 4%, C18 = 6% Phase type Monofunctional and fully endcapped Silica Class Type A Hardware Stainless steel and PEEK columns and cartridges Applications HAISIL 300 columns and cartridges are ideal for biomolecule separations such as peptides and small proteins. Optimized phase bonding and column packing techniques assure unsurpassed performance and column-to-hcolumn reproducibility in comparison to other so-hcalled wide pore reverse phase columns offered by other manufacturers. Short cartridge columns are economical and are ideally suited for LC/MS applications. The column and cartridge offering ranges from 150µm to 20mm I.D. which means that bioseparations can be optimized by selecting a format that best fits your analytical requirements. Peptide Standards separated on a 250x1.0mm column (HW185-HS2501) with an efficiency that permits collection of 10µL peaks Higgins Analytical's high performance microbore HPLC columns. We're so confident about our ALGO Series HAISIL 300 C18 5µm performance, we challenge anyone to manufacture a better one. Depending upon the type of information a protein chemist is seeking, the HPLC analysis of a complex digest can take 1 to 2 hours. The following

19 HAISIL chromatogram illustrates a high resolution tryptic digest map of BSA on a 250x2.1mm HAISIL 300 C18 5µm Tryptic Map of BSA on HAISIL 300 C18 5um (250x4.6mm P/N HW185-HS2546) column indicates peak capacities in excess of 100. Small proteins, on the other hand can yield fewer fragments, and if only a "fingerprint" of a digest is required, high peak capacity columns can be a waste of time. column provides hundreds of runs without performance loss even under the aggressive 6ml/min flow conditions used in this example. Fast Analysis of a Complex Drug Delivery System Most pharmaceutical QC laboratories are faced with rapidly increasing demands for high throughput capability. A good example of one laboratory's approach to addressing a large number of samples for analysis on a daily basis is summarized below. This novel drug delivery system contains a small protein and other components that span an order of magnitude in molecular weight. All the identification of more than 10,000 peptides. These distinct peptides are bound to a major histocompatibility complex (MHC) molecule on tumor cells. Extraction of approximately 5x10 10 cells yield several nanomoles of a very complex peptide mixture. Several rounds of RP-HPLC with different organic modifiers on a 40x2.1mm PEEK cartridge column (HAISIL 300 C18 5µm, P/N: HK0421- HW185) are performed to fractionate the mixture into individual components. The chromatograms below illustrate how this technique is being used to narrow the search for the one peptide that marks a particular tumor cell as being diseased enabling it to be recognized by the immune cells. Fractionation of a Purified Tumor Cell Extract Peptides ranging from 100 fmol to 1pmol are collected in 40sec intervals during a 70min gradient from 0-60% MeCN with HFBA modifier. A 40x2.1mm HAISIL 300 C18 5µm cartridge column (HK0421-HW185) is used. 5min Tryptic Map of Cytochrome-C on a 5cm HAISIL 300 C18 column Peptide Map in 5 minutes The figure below illustrates a very fast peptide map of cytochrome-c. The information that can be gleaned from this five minute profile is more than adequate for many analytical requirements. The robust 50x4.6mm HAISIL 300 C18 Fast Tryptic Map of rhgh 50x4.6mm HAISIL 300 C18 Micro-Preparative HPLC Higgins Analytical Cartridge Columns are helping researchers understand the immune response of living cells. An investigation to understand the genetic control of the immune response systems in organisms involves the extraction, isolation, and Reanalysis of a Fraction from the Chromatogram above The same 40x2.1mm HAISIL 300 cartridge is used for a 70min gradient from 0-60% MeCN with TFA modifier. Tic marks indicate 40sec fraction collections.

20 Nanobore Columns HAISIL 300 C4 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HW045-HN0315 $300 HW045-HN0515 $300 HW045-HN1015 $350 HAISIL 300 C8 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HW045-HN0315 $300 HW045-HN0515 $300 HW085-HN1015 $350 HAISIL 300 C18 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HW185-HN0315 $300 HW185-HN0515 $300 HW185-HN1015 $350 Microbore Columns HAISIL 300 C4 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HW045-HS0301 $250 HW045-HS0501 $250 HW045-HS1001 $275 HW045-HS1501 $300 HW045-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HW045-HS03M5 $250 HW045-HS05M5$250 HW045-HS10M5 $275 HW045-HS15M5 $300 30x0.3mm 50x0.3mm 100x0.3mm HW045-HS03M3 $250 HW045-HS05M3$250 HW045-HS10M3 $275 HAISIL 300 C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HW085-HS0301 $250 HW085-HS0501 $250 HW085-HS1001 $275 HW085-HS1501 $300 HW085-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HW085-HS03M5 $250 HW085-HS05M5$250 HW085-HS10M5 $275 HW085-HS15M5 $300 30x0.3mm 50x0.3mm 100x0.3mm HW085-HS03M3 $250 HW085-HS05M3$250 HW085-HS10M3 $275 HAISIL 300 C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HW185-HS0301 $250 HW185-HS0501 $250 HW185-HS1001 $275 HW185-HS1501 $300 HW185-HS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HW185-HS03M5 $250 HW185-HS05M5$250 HW185-HS10M5 $275 HW185-HS15M5 $300 30x0.3mm 50x0.3mm 100x0.3mm HW185-HS03M3 $250 HW185-HS05M3 $250 HW185-HS10M3 $275 Analytical Columns - Stainless Steel HAISIL 300 C4 5µm 4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HW045-HS0346 $230 HW045-HS0546 $240 HW045-HS1046 $250 HW045-HS1546 $285 HW045-HS2546 $300 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HW045-HS0330 $230 HW045-HS0530 $240 HW045-HS1030 $250 HW045-HS1530 $285 HW045-HS2530 $300 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HW045-HS0321 $230 HW045-HS0521 $240 HW045-HS1021 $250 HW045-HS1521 $285 HW045-HS2521 $300 HAISIL 300 C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HW085-HS0346 $230 HW085-HS0546 $240 HW085-HS1046 $250 HW085-HS1546 $285 HW085-HS2546 $300 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HW085-HS0330 $230 HW085-HS0530 $240 HW085-HS1030 $250 HW085-HS1530 $285 HW085-HS2530 $300 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HW085-HS0321 $230 HW085-HS0521 $240 HW085-HS1021 $250 HW085-HS1521 $285 HW085-HS2521 $300 HAISIL 300 C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HW185-HS0346 $230 HW185-HS0546 $240 W185-HS1046 $250 HW185-HS1546 $285 HW185-HS2546 $300 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HW185-HS0330 $230 HW185-HS0530 $240 HW185-HS1030 $250 HW185-HS1530 $285 HW185-HS2530 $300 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HW185-HS0321 $230 HW185-HS0521 $240 HW185-HS1021 $250 HW185-HS1521 $285 HW185-HS2521 $300

21 HAISIL 300 Ordering Information 1 PEEK Analytical Columns HAISIL 300 C4 5µm 4.6, 3.0, and 2.1mm I.D. PEEK Analytical Columns 50x4.6mm 75x4.6mm 100x4.6mm 150x4.6mm HW045-HP0546 $300 HW045-HP0746 $300 HW045-HP1046 $300 HHW045-P1546 $330 50x3.0mm 75x3.0mm 100x3.0mm 150x3.0mm HW045-HP0530 $300 HW045-HP0730 $300 HW045-HP1030 $300 HW045-HP1530 $330 50x2.1mm 75x2.1mm 100x2.1mm HW045-HP0521 $300 HW045-HP0721 $300 HW045-HP1021 $300 HAISIL 300 C8 5µm HAISIL 300 C18 5µm 4.6, 3.0, and 2.1mm I.D. PEEK Analytical Columns 50x4.6mm 75x4.6mm 100x4.6mm 150x4.6mm HW085-HP0546 $300 HW085-HP0746 $300 HW085-HP1046 $300 HW085-HP1546 $330 50x3.0mm 75x3.0mm 100x3.0mm 150x3.0mm HW085-HP0530 $300 HW085-HP0730 $300 HW085-HP1030 $300 HW085-HP1530 $330 50x2.1mm 75x2.1mm 100x2.1mm HW085-HP0521 $300 HW085-HP0721 $300 HW085-HP1021 $ , 3.0, and 2.1mm I.D. PEEK Analytical Columns 50x4.6mm 75x4.6mm 100x4.6mm 150x4.6mm HW185-HP0546 $300 HW185-HP0746 $300 HW185-HP1046 $300 HW185-HP1546 $330 50x3.0mm 75x3.0mm 100x3.0mm 150x3.0mm HW185-HP0530 $300 HW185-HP0730 $300 HW185-HP1030 $300 HW185-HP1530 $330 50x2.1mm 75x2.1mm 100x2.1mm HW185-HP0521 $300 HW185-HP0721 $300 HHW185-P1021 $300 HAICART - Stainless Steel Analytical Cartridge Columns HAISIL 300 C4 5µm 4.6 and 3.2mm I.D. s.s. HAICART Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HW045-HF0446 $260 HW045-HF0546 $265 HW045-HF1046 $230 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HW045-HF0432 $260 HW045-HF0532 $265 HW045-HF1032 $230 HAISIL 300 C8 5µm 4.6 and 3.2mm I.D. s.s. HAICART Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HW085-HF0446 $260 HW085-HF0546 $265 HW085-HF1046 $230 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HW085-HF0432 $260 HW085-HF0532 $265 HW085 -HF1032$230 HAISIL 300 C18 5µm 4.6 and 3.2mm I.D. s.s. HAICART Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HW185-HF0446 $260 HW185-HF0546 $265 HW185-HF1046 $230 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HW185-HF0432 $260 HW185-HF0532 $265 HW185-HF1032 $230 HAIPEEK - PEEK Analytical Cartridge Columns HAISIL 300 C4 5µm HAISIL 300 C8 5µm HAISIL 300 C18 5µm 2.1mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HW045-HK0421 $235 HW045-HK0521 $ mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HW085-HK0421 $235 HW085-HK0521 $ mm I.D. PEEK HAIPEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HW185-HK0421 $235 HW185-HK0521 $240

22 See Pages for information about holders required for these cartridge columns. Semi-Prep and Prep Columns HAISIL 300 C4 5µm HAISIL 300 C8 5µm HAISIL 300 C18 5µm 10mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HW045-HS0510 $450 HW045-HS1010 $475 HW045-HS1510 $650 HW045-HS2510 $865 50x20mm 100x20mm 150x20mm 250x20mm HW045-HS0520 $1150 HW045-HS1020$1200 HW045-HS1520 $1500 HW045-HS2520 $ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HW085-HS0510 $450 HW085-HS1010 $475 HW085-HS1510 $650 HW085-HS2510 $865 50x20mm 100x20mm 150x20mm 250x20mm HW085-HS0520 $1150 HW085-HS1020$1200 HW085-HS1520 $1500 HW085-HS2520 $ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HW185-HS0510 $450 HW185-HS1010 $475 HW185-HS1510 $650 HW185-HS2510 $865 50x20mm 100x20mm 150x20mm 250x20mm HW185-HS0520 $1150 HW185-HS1020$1200 HW185-HS1520 $1500 HW185-HS2520 $2200 HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns HAISIL 300 C4 5µm HAISIL 300 C8 5µm HAISIL 300 C18 5µm 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HW045-HF0310 $250 HW045-HF0510 $295 HW045-HF1010 $370 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HW085-HF0310 $250 HW085-HF0510 $295 HW085-HF1010 $370 10mm I.D. s.s. Analytical / Semi-Prep Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HW185-HF0310 $250 HW185-HF0510 $295 HW185-HF1010 $370 HAISpeed20-20mm I.D. Prep Guard Cartridges HAISIL 300 C18 10µm 20mm I.D. Stainless Steel Prep Guard Cartridge 25x20mm 2/pkg HW181-HF0220$270

23 HAISIL 300 Ordering Information Guard Cartridges - 3.2mm I.D. HAISIL 300 C4 5µm HAISIL 300 C8 5µm HAISIL 300 C18 5µm HAICART Guard Cartridges 20x3.2mm 5/pkg HH304 $155 HAICART Guard Cartridges 20x3.2mm 5/pkg HH308 $155 HAICART Guard Cartridges 20x3.2mm 5/pkg HH318 $155 The Role of Column Length in Gradient Separations Changes in column length have a direct and linear effect on theoretical plates and analysis time in isocratic separations. Column length plays a less important role, however, in gradient techniques. The three chromatograms below illustrate how well packed short HPLC columns yield very similar peptide separations under identical gradient conditions. Guard Cartridges - 2.1mm I.D. HAISIL 300 C4 5µm PEEK HAIPEEK Guard Cartridges 20x2.1mm 5/pkg HW045-HK0221$160 For this study, the 2.1mm I.D. HAISIL 300 C18 5µm columns ranged from 250 to 100mm in length. While solvent and analysis time savings may be minimal, column cost savings can be significant when using as short a column as possible. Short columns also exhibit lower pressure at high flow rates. HAISIL 300 C8 5µm PEEK HAIPEEK Guard Cartridges 20x2.1mm 5/pkg HW085-HK0221$ x2.1mm HAISIL 300 C18 5µm HW185-HS2521 HAISIL 300 C18 5µm HAIPEEK Guard Cartridges 20x2.1mm 5/pkg HW185-HK0221$ x2.1mm HAISIL 300 C18 5µm HW185-HS1521 HAICART (stainless steel) and HAIPEEK (PEEK) guard cartridges are compatible with Higgins Analytical HAIPEEK Guard Holders and the PE Brownlee NewGuard Holder. 100x2.1mm HAISIL 300 C18 5µm HW185-HS Gly-Tyr 2. Val-Tyr-Val 3. Met Enkephalin 4. Leu Enkephalin 5. Angiotensin II

24 HAISIL HL - High Load Columns Often, a chromatographer needs to support the high sample throughput demands of real-time process control or large volume production monitoring. When maximum selectivity, high efficiency, and fast analysis times are called for, HAISIL HL (high load) C18 is a good choice. The high surface area (300m 2 /gm) of the 100Å pore size silica used for HAISIL HL permits high weight/weight carbon loading yet the same desirable monomeric characteristics of our other HAISIL sorbents. HPLC Peptide Standards for RP on the HAISIL HL C18 Column The aromatic hydrocarbons that most 1. H 2 N-RGAGGLGLGK-amide 2. AC-RGGGGLGLGK-amide 3. AC-RGAGGLGLGK-amide 4. AC-RGVGGLGLGK-amide 5. AC-RGVVGLGLGK-amide HPLC column manufacturers use to quality control columns render little information about a column's selectivity and performance characteristics for peptides. The Canadian corporation, SPI, produces a well characterized yet challenging peptide mixture that is very useful for quantifying HPLC column performance for peptides. The difficult to separate first pair of peptides are resolved to near base line on HAISIL HL C18 columns. Many so called peptide analysis columns are unable to separate this pair. Food Additives Beverage additive analysis is not only an important industrial application, but Caffeine Aspartame Sodium Benzoate HAISIL HL High Load Hodges Test Peptide Mix (from Synthetic Peptides, Inc.) HAISIL HL C18 5µm 150x4.6mm P/N HC185-LS1546 Phases C18 Particle Sizes 3 and 5µm Pore Size 100Å Pore Volume 0.8mL/gm Surface Area 300m 2 /gm %Carbon (w/w) C18 = 18% Phase type Monofunctional & fully endcapped Silica Class Type B Hardware Stainless steel and PEEK columns and cartridges Applications HAISIL HL high load columns and cartridges are intended for applications requiring maximum loading and selectivity. The high surface area permits high bonded phase loading yet the monofunctional bonded phase and the absence of micro-pores eliminates the problems that plague many of the so called high capacity columns currently on the market. The Type B silica backbone is pure, robust, and stable under harsh conditions. Users report satisfactory lifetime when used for prolong periods at ph as high as 9. Fast Diet Cola Analysis HAISIL HL C18 5µm 2cm x 2.1mm Cartridge P/N HC185-LK % MeCN/water 200µL/min it also serves as a practical and relatively simple procedure for introductory HPLC courses. Industry is increasingly driven by rapid analysis requirements and an HPLC column can represent an overwhelming expense in a teaching environment. The diet cola analysis in the chromatogram to the left illustrates an extremely fast analysis on an extremely inexpensive HPLC column. A package containing five of the 20x2.1mm cartridge column used for this analysis costs about half as much as one moderately priced HPLC column. And, there's no need to pre-filter the cola sample

25 HAISIL HL High Load through a 0.5µm filter as some column manufacturers recommend when using their expensive columns packed with 2µm particles for this analysis! LC/MS applications. The figure below illustrates a routine LC/MS analysis of a 20µL serum sample on a 40x2.1mm HAIPEEK cartridge. These inexpensive cartridges are reported to have a several hundred cycle minimum life. Paraben Food Preservatives Parabens represent another example of food additives that are routinely analyzed by HPLC. Often, the food matrix being assayed for preservative content requires exhaustive cleanup and pre-filtration in order to prevent pounds containing two identical building blocks. A-B and B-A r resent positional isomers, each containing two building blocks. This analysis was conducted on the crude liquid-phase reaction mixture. Each component contains Basic Compounds in Combinatorial Mixtures HAISIL HL C18 P/N HC185-LS1546 Water Soluble Vitamins HAISIL HL C18 5µm 250x4.6mm A: 0.05mM KOAc, ph5; B: MeCN Gradient: 2.5% - 30%B in 25min The readily available and non-toxic nature of the sample and the low cost of Higgins Analytical cartridges has made the diet cola analysis an ideal choice for classroom purposes. Cartridge Columns for LC/MS With MS becoming the detector of choice for a rapidly increasing number of fortunate chromatographers, the need for dependable, efficient, and short HPLC columns has grown dramatically. Higgins Analytical offers a wide range of short, 2.1mm I.D. cartridge columns that are ideal for LC/MS of Serum Drug HAISIL HL C18 5µm 40x2.1mm Cartridge P/N LK0421-HC185 Sciex API3+ LOQ: 5ng/mL LOD: 5pg Fast Paraben Analysis HAISIL HL C18 5µm 20x2.1mm Cartridge HC185-LK µL/min, 40% MeCN/water clogging of columns with nonporous or 2µm sorbents recently suggested for this analysis. As in the previous diet cola example, the compounds of interest are base line resolved under isocratic conditions. The inexpensive HAISIL HL 5µm 20x2.1mm cartridge column and the 50 second analysis time contribute significantly towards reducing operating costs. Reverse Phase Chromatography of Basic Compounds in Combinatorial Mixtures In the example at the top of the next column, A and B are single com- multiple secondary and tertiary amine functionality yet the combin torial products can be rapidly chromatographed and exhibit no ta ing on a 150x4.6mm HAISIL HL C18 column using a simple linea 5% to 100% MeCN/water 0.1% TFA gradient. Speed and Selectivity for Ballistic Gradients on Complex Libraries The relative importance of particle size and selectivi are graphically illustrated below by the high speed analysis of a six component combinatorial library on HAISIL HL C18 5µm column and two competitor s C18 2µm columns. HAISIL HL with its high carbon loading and surface area of often works much bette than expensive small particle size columns that are prone to plugging up more quickly. HAISIL HL 5µm C18 Competitor A 2µm C18 Competitor B 2µm C18

26 Nanobore Columns HAISIL HL C18 3µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HC183-LN0315 $350 HC183-LN0515 $350 HC183-LN1015 $375 HAISIL HL C18 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm 150x0.15mm HC185-LN0315 $300 HC185-LN0515 $300 HC185-LN1015 $325 HC185-LN1515 $350 Microbore Columns HAISIL HL C18 3µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm HC183-LS0301 $270 HC183-LS0501 $285 HC183-LS1001 $295 HC183-LS1501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC183-LS03M5 $270 HC183-LS05M5 $285 HC183-LS10M5 $295 HC183-LS15M5 $325 30x0.3mm 50x0.3mm 100X0.3mm HC183-LS03M3 $270 HC183-LS05M3 $285 HC183-LS10M3 $295 HAISIL HL C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC185-LS0301 $250 HC185-LS0501 $260 HC185-LS1001 $270 HC185-LS1501 $280 HC185-LS2501 $325 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC185-LS03M5 $250 HC185-LS05M5 $260 HC185-LS10M5 $270 HC185-LS15M5 $280 30x0.3mm 50x0.3mm 100x0.3mm 150x0.3mm HC185-LS03M3 $250 HC185-LS05M3 $260 HC185-LS10M3 $270 HC185-LS15M3 $280 Analytical Columns - Stainless Steel HAISIL HL C18 3µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 3µm SERIES 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC183-LS0346 $270 HC183-LS0546 $285 HC183-LS1046 $295 HC183-LS1546 $325 HC183-LS2546 $350 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC183-LS0330 $270 HC183-LS0530 $285 HC183-LS1030 $295 HC183-LS1530 $325 HC183-LS2530 $350 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC183-LS0321 $270 HC183-LS0521 $285 HC183-LS1021 $295 HC183-LS1521 $325 HC183-LS2521 $350 HAISIL HL C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC185-LS0346 $250 HC185-LS0546 $260 HC185-LS1046 $270 HC185-LS1546 $280 HC185-LS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC185-LS0330 $250 HC185-LS0530 $260 HC185-LS1030 $270 HC185-LS1530 $280 HC185-LS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC185-LS0321 $250 HC185-LS0521 $260 HC185-LS1021 $270 HC185-LS1521 $280 HC185-LS2521 $325 Semi-Prep and Prep Columns HAISIL HL C18 5µm 10mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HC185-LS0510 $475 HC185-LS1010 $500 HC185-LS1510 $650 HC185-LS2510 $900 50x20mm 100x20mm 150x20mm 250x20mm HC185-LS0520 $960 HC185-LS1020 $1200 HC185-LS1520 $1500 HC185-LS2520 $2200

27 HAISIL HL High Load Ordering Information 2 HAICART - Stainless Steel Analytical Cartridge Columns HAISIL HL C18 3µm HAISIL HL C18 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC183-LF0446 $285 HC183-LF0546 $295 HC183-LF1046 $285 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC183-LF0432 $285 HC183-LF0532 $295 HC183-LF1032 $ and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC185-LF0446 $260 HC185-LF0546 $270 HC185-LF1046 $260 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC185-LF0432 $260 HC185-LF0532 $270 HC185-LF1032 $260 HAIPEEK - PEEK Analytical Cartridge Columns HAISIL HL C18 5µm 2.1mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC185-LK0421 $235 HC185-LK0521 $240 HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns HAISIL 100 C18 5µm 10mm I.D. s.s. HAISpeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC185-LF0310 $250 HC185-LF0510 $295 HC185-LF1010 $370 HAICART - Stainless Steel Guard Cartridges HAISIL HL C18 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HL118 $160 HAIPEEK - PEEK Guard Cartridges HAISIL HL C18 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC185-LK0221 $165 See Pages for information about holders required for these cartridge columns. HAICART (stainless steel) and HAIPEEK (PEEK) guard cartridges are compatible with Higgins Analytical HAIPEEK Guard Holders and the PE Brownlee NewGuard Holder.

28 Unrivaled End Capping Technology Efforts to eliminate solute-silanol interactions have recently lead to big advancements in sorbent chemistry. While secondary effects can be vital for obtaining desired selectivity in some applications, they rarely help when polar amines are being analyzed. Targa HPLC columns are true to the Latin root of their name. TARGA, meaning shield, is precisely the effect the unique bonded phase has on the silica s silanol surface. Many HPLC column manufacturers illustrate the performance of their columns packed with inert, base deactivated, Type B silica bonded phases by the chromatographic behavior of polar compounds such as pyridine. Performance claims Unbuffered 20% MeCN/water A more revealing test for solute-silanol interaction is to use a mobile phase containing a relatively low amount of organic solvent and no additives or buffers. Compared to three popular HPLC columns whose manufacturers claim have a high degree of inertness, TARGA C18 exhibits very good efficiency and symmetry for pyridine. Pyridine Phenol Pyridine Phenol Pyridine Phenol Peptide Mapping without TFA The following chromatograms illustrate the differences in selectivity for peptide maps of cytochrome-hc when using 0.05% TFA or 0.05% acetic acid buffer TARGA C18 Hypersil BDS Kromasil C18 Unbuffered 40% MeCN/water can be misleading, however, when mobile phases are buffered to low ph or when they contain high percentages of organic solvent. TARGA - A uniquely shielded surface Phases C8 and C18 Particle Sizes 3 and 5µm Pore Size 120Å Pore Volume 0.8mL/gm Surface Area 330m 2 /gm %Carbon (w/w) C8 = 8%, C18 = 16% Phase type Monofunctional with a unique polar and bulky end- Capping Silica Class Type B Hardware Stainless steel and PEEK columns and cartridges Applications TARGA columns and cartridges are ideal for applications requiring an absence of secondary solute-silanol interaction. Basic and acidic drugs and peptides can be chromatographed efficiently with little or no buffer. Targa columns are particularly well suited for LC/MS applications where acetic acid or formic acid can be substituted for TFA resulting in significant increase in signal. While TFA is not required, it does not preclude its use on TARGA columns. TARGA exhibits extremely fast equilibration kinetics from high to low organic phase compositions. It works well in in 1%/min acetonitrile gradient on a short 50x1.0mm TARGA C18 column. Both dilute buffer examples are characterized by sharp peaks and no tailing LC/MS without TFA Researchers have shown that Higgins Analytical s TARGA C8 and C18 phases have an extremely well protected silanol surface. An acetonitrile/water 1%/min gradients with as little as 0.05% acetic

29 TARGA A Popular Hydrophilic RP Column Phenol Pyridine Pyridine Phenol Basic Peptides with 0.1% Acetic Acid ph 3.1 TARGA C18 5µm 50x1.0mm acid gives a very satisfactory peptide map on a short 5cm x 1mm TARGA C18 column. The ability to buffer with acetic or formic acid rather than TFA greatly enhances signals for LC/MS techniques. While TARGA columns give exceptional Fat-Soluble Vitamin Assay TARGA C18 5µm 100x2.1mm Part Number HC185-TS1021 3% water in MeOH mobile phase 200µl/min, diode array detection reequilibration. Fast gradients can be run on TARGA columns from initial 100% aqueous conditions with fast cycle times and very good run-to-run reproducibility. TARGA columns can A TARGA C18 Column TARGA compared to a competitor s hydophilic column. 150x4.6mm, 20% MeCN/water (unbuffered) 1mL/min TARGA s Superior Hydrophilic Reverse Phase Properties Several manufacturers offer reverse phase column products with imbedded polar functionality intended to enhance the chromatography of hydrophilic compounds like those illustrated in the previous antibacterial example. Unfortunately, most of these approaches introduce undesirable secondary effects that preclude their use with acidic or basic solutes unlike TARGA with its unique bonded phase. Trace Catecholamine Analysis In vivo microdialysis present a challenge to both instrumentation and column design, especially when depended upon as a tool for routine analysis. The chrmatogram below Basic Peptides with 0.1% TFA ph 2.2 TARGA C18 5µm 50x1.0mm performance without TFA buffer, it does not mean that you are precluded from using it. In fact, the changes in selectivity that comes with changing buffer acids can be a powerful tool for separation optimization. Notice how the peptide elution orders change between the acetic acid and TFA buffered chromatograms above. Favorable Kinetics at Aqueous or Organic Mobile Phase Extremes The bulky moiety used for end capping TARGA C8 and C18 sorbents present other valuable selectivity characteristics in addition to the extreme inertness to basic and acidic compounds. Long chain alkane bonded phases collapse under low organic phase conditions on most reverse phase HPLC columns causing poor reproducibility and slow Analysis of Very Polar Antibacterials with a Highly Aqueous Mobile Phase 1. Vancomycin, 2. Cefotaxime, 3. Cefazolin TARGA C18 100x2.1mm TS1021-HC185 Mobile Phase: 92% Water with 0.l% TFA ph2.5, 8% MeOH, DAD at 230nm also be run isocratically in 100% aqueous conditions for carbohydrate analysis, or with only a few percent organic modifier to achieve selectivity on solutes that are retained under typical reverse phase conditions. 5HT Analysis of Rat Hypothalamus Dialysate TARGA C18 5µm 100x2.1mm P/N HC185-TS1021 NaH 2 PO M OSA 0.74mM EDTA 0.1mM ph 2.87 (orthophosphoric acid) 2% IPA Instrumentation: Flux Rheos Isocratic Pump, In-line Solvent Degasser, Spark Holland Triathlon Autosampler, Antec INTRO EC Detector Detection levels of nm are routinely achieved. illustrates rat hypothalamus microdialysis analysis for 5HT. Researchers report that

30 Nanobore Columns TARGA C8 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HC085-TN0315 $300 HC085-TN0515 $300 HC085-TN1015 $325 TARGA C18 3µm 0.15mm I.D 30x0.15mm 50x0.15mm 100x0.15mm HC183-TN0315 $350 HC183-TN0515 $350 HC183-TN1015 $375 TARGA C18 5µm 0.15mm I.D 30x0.15mm 50x0.15mm 100x0.15mm HC185-TN0315 $300 HC185-TN0515 $300 HC185-TN1015 $325 Microbore Columns TARGA C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC085-TS0301 $290 HC085-TS0501 $300 HC085-TS1001 $325 HC085-TS1501 $350 HC085-TS2501 $380 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC085-TS03M5 $290 HC085-TS05M5 $300 HC085-TS10M5 $325 HC085-TS15M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HC085-TS03M3 $290 HC085-TS05M3 $300 HC085-TS10M3 $325 TARGA C18 3µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC183-TS0301 $340 HC183-TS0501 $350 HC183-TS1001 $375 HC183-TS1501 $400 HC183-TS2501 $425 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC183-TS03M5 $340 HC183-TS05M5 $350 HC183-TS10M5 $375 HC183-TS15M5 $400 30x0.3mm 50x0.3mm 100x0.3mm HC183-TS03M3 $340 HC183-TS05M3 $350 HC183-TS10M3 $375 TARGA C18 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC185-TS0301 $290 HC185-TS0501 $300 HC185-TS1001 $325 HC185-TS1501 $350 HC185-TS2501 $380 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC185-TS03M5 $290 HC185-TS05M5 $300 HC185-TS10M5 $325 HC185-TS15M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HC185-TS03M3 $290 HC185-TS05M3 $300 HC185-TS10M3 $325 Analytical Columns - Stainless Steel TARGA C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC085-TS0346 $270 HC085-TS0546 $280 HC085-TS1046 $300 HC085-TS1546 $325 HC085-TS2546 $345 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC085-TS0330 $270 HC085-TS0530 $280 HC085-TS1030 $300 HC085-TS1530 $325 HC085-TS2530 $345 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC085-TS0321 $270 HC085-TS0521 $280 HC085-TS1021 $300 HC085-TS1521 $325 HC085-TS2521 $345 TARGA C18 3µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC183-TS0346 $340 HC183-TS0546 $350 HC183-TS1046 $375 HC183-TS1546 $400 HC183-TS2546 $425 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC183-TS0330 $340 HC183-TS0530 $350 HC183-TS1030 $375 HC183-TS1530 $400 HC183-TS2530 $425 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC183-TS0321 $340 HC183-TS0521 $350 HC183-TS1021 $375 HC183-TS1521 $400 HC183-TS2521 $425 TARGA C18 5µm 4.6, 3.0, and 2.1mm I.D. s.s. columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC185-TS0346 $270 HC185-TS0546 $280 HC185-TS1046 $300 HC185-TS1546 $325 HC185-TS2546 $345 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC185-TS0330 $270 HC185-TS0530 $280 HC185-TS1030 $300 HC185-TS1530 $325 HC185-TS2530 $345 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC185-TS0321 $270 HC185-TS0521 $280 HC185-TS1021 $300 HC185-TS1521 $325 HC185-TS2521 $345

31 TARGA Ordering Information 2 Semi-Prep and Prep Columns TARGA C8 5µm TARGA C18 10µm TARGA C18 5µm 10mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm HC085-TS0510 $ x10mm HC085-TS1010 $ x10mm HC085-TS1510 $ x10mm HC085-TS2510 $ x20mm 100x20mm 150x20mm 250x20mm HC085-TS0520 $1120 HC085-TS1020 $1400 HC085-TS1520 $1850 HC085-TS2520 $ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm HC181-TS0510 $ x10mm HC181-TS1010 $ x10mm HC181-TS1510 $ x10mm HC181-TS2510 $670 50x20mm 100x20mm 150x20mm 250x20mm HC181-TS0520 $755 HC181-TS1020 $945 HC181-TS1520 $1230 HC181-TS2520 $ mm & 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm HC185-TS0510 $ x10mm HC185-TS1010 $ x10mm HC185-TS1510 $ x10mm HC185-TS2510 $ x20mm 100x20mm 150x20mm 250x20mm HC185-TS0520 $1120 HC185-TS1020 $1400 HC185-TS1520 $1850 HC185-TS2520 $2400 HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns TARGA C8 5µm TARGA C18 10µm TARGA C18 5µm 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC085-TF0310 $250 HC085-TF0510 $295 HC085-TF1010 $370 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC181-TF0310 $170 HC181-TF0510 $195 HC181-TF1010 $250 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC185-TF0310 $250 HC185-TF0510 $295 HC185-TF1010 $370 HAISpeed20-20mm I.D. Prep Guard Cartridges TARGA C18 10µm 20mm I.D. Stainless Steel Prep Guard Cartridge 25x20mm 2/pkg HC181-TF0220 $325 Anti-Hypertensives TARGA C18 150x4.6mm P/N: HC185-TS % MeCN/Buffer, 1mL/min, 260nm Buffer: 20mM NaH 2 PO 4, ph Triamterene 2. Hydrochlorothiazide See Pages for information about holders required for these cartridge columns.

32 TARGA Ordering Information HAICART - Stainless Steel Analytical Cartridge Columns TARGA C8 5µm 4.6 and 3.2mm I.D. s.s. HAICART Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC085-TF0446 $250 HC085-TF0546 $260 HC085-TF1046 $250 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC085-TF0432 $250 HC085-TF0532 $260 HC085-TF1032 $250 TARGA C18 5µm 4.6 and 3.2mm I.D. s.s. HAICART Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC185-TF0446 $250 HC185-TF0546 $260 HC185-TF1046 $250 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC185-TF0432 $250 HC185-TF0532 $260 HC185-TF1032 $250 HAIPEEK - PEEK Analytical Cartridge Columns TARGA C8 5µm TARGA C18 3µm TARGA C18 5µm 2.1mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC085-TK0421 $250 HC085-TK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC183-TK0421 $350 HC183-TK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC185-TK0421 $250 HC185-TK0521 $260 Tryptic Map of Human Ocular Lens Proteins beta A1 crystallin and gamma S crystallin TARGA C18 5µm 150x0.5mm P/N HC185-TS15M5 HAICART - Stainless Steel Guard Cartridges Solvent A: 0.1% Acetic Acid Solvent B: 0.1% Acetic Acid, 65% MeCN 0-50% B in 60min, %B in 15min TARGA C8 5µm TARGA C18 5µm 3.2mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HT108 $ mm I.D. s.s. Guard Cartridges 20x3.2mm 5/pkg HT118 $150 Sample is a tryptic digest of a 2D electrophoresis separated spot digested from PDVF membrane. The two ocular proteins are ~25kD. The LC/MS zoom scan below confirms the peak at 39.15min is singly charged, and software interpretation of the MS/MS scan at the bottom confirms the ion as residues in human gamma S crystallin. HAIPEEK - PEEK Guard Cartridges TARGA C8 5µm TARGA C18 3µm TARGA C18 5µm 2.1mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC085-TK0221 $ mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC183-TK0221 $ mm I.D. PEEK Guard Cartridges 20x2.1mm 5/pkg HC185-TK0221 $155 See Pages for information about holders required for these cartridge

33 KROMASIL 100 Ordering Information Kromasil 100 Phases C8 and C18 Particle Sizes 3.5 and 5µm Pore Size 110Å Pore Volume 0.9mL/gm Surface Area 330m 2 /gm %Carbon (w/w) C8 = 12%, C18 = 20% Silica Class Type B Hardware Stainless steel and PEEK columns and cartridges Nanobore Columns The only commercially available sorbent offered in our product family, Kromasil has become well known for its unique selectivity, robust mechanical and chemical structure, and wide use in pharmaceutical process scale facilities. Higgins Analytial s ability to manufacture Kromasil HPLC columns that have unrivaled performance has made us an economically competitive and routine supplier of very high quality Kromasil columns to laboratories and OEM customers on five continents. Kromasil Kromasil 100 C8 5µm 0.15mm I.D. 30x0.15mm 50x0.15mm 100x0.15mm HC085-KN0315 $300 HC085-KN0515 $300 HC085-KN1015 $325 Kromasil 100 C18 3.5µm 0.15mm I.D 30x0.15mm 50x0.15mm 100x0.15mm HC183-KN0315 $325 HC183-KN0515 $325 HC183-KN1015 $350 Kromasil 100 C18 5µm 0.15mm I.D 30x0.15mm 50x0.15mm 100x0.15mm HC185-KN0315 $300 HC185-KN0515 $300 HC185-KN1015 $325 Microbore Columns Kromasil 100 C8 5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC085-KS0301 $280 HC085-KS0501 $290 HC085-KS1001 $300 HC085-KS1501 $325 HC085-KS2501 $350 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC085-KS03M5 $280 HC085-KS05M5 $290 HC085-KS10M5 $300 HC085-KS15M5 $325 30x0.3mm 50x0.3mm 100x0.3mm HC085-KS03M3 $280 HC085-KS05M3 $290 HC085-KS10M3 $300 Kromasil 100 C18 3.5µm 1.0mm - 0.5mm - 0.3mm I.D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC183-KS0301 $305 HC183-KS0501 $315 HC183-KS1001 $325 HC183-KS1501 $350 HC183-KS2501 $375 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC183-KS03M5 $305 HC183-KS05M5 $315 HC183-KS10M5 $325 HC183-KS15M5 $350 30x0.3mm 50x0.3mm 100x0.3mm HC183-KS03M3 $305 HC183-KS05M3 $315 HC183-KS10M3 $325 Kromasil 100 C18 5µm1.0mm - 0.5mm - 0.3mm I..D. 30x1.0mm 50x1.0mm 100x1.0mm 150x1.0mm 250x1.0mm HC185-KS0301 $280 HC185-KS0501 $290 HC185-KS1001 $300 HC185-KS1501 $325 HC185-KS2501 $350 30x0.5mm 50x0.5mm 100x0.5mm 150x0.5mm HC185-KS03M5 $280 HC185-KS05M5 $290 HC185-KS10M5 $300 HC185-KS15M5 $325 30x0.3mm 50x0.3mm 100x0.3mm HC185-KS03M3 $280 HC185-KS05M3 $290 HC185-KS10M3 $300

34 See Pages for information about holders required for these cartridge columns. Analytical Columns - Stainless Steel Kromasil 100 C8 5µm 4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC085-KS0346 $250 HC085-KS0546 $260 HC085-KS1046 $270 HC085-KS1546 $300 HC085-KS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC085-KS0330 $250 HC085-KS0530 $260 HC085-KS1030 $270 HC085-KS1530 $300 HC085-KS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC085-KS0321 $250 HC085-KS0521 $260 HC085-KS1021 $270 HC085-KS1521 $300 HC085-KS2521 $325 Kromasil 100 C18 3.5µm 4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC183-KS0346 $280 HC183-KS0546 $290 HC183-KS1046 $300 HC183-KS1546 $325 HC183-KS2546 $350 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC183-KS0330 $280 HC183-KS0530 $290 HC183-KS1030 $300 HC183-KS1530 $325 HC183-KS2530 $350 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC183-KS0321 $280 HC183-KS0521 $290 HC183-KS1021 $300 HC183-KS1521 $325 HC183-KS2521 $350 Kromasil 100 C18 5µm4.6, 3.0, and 2.1mm I.D. s.s. Analytical Columns 30x4.6mm 50x4.6mm 100x4.6mm 150x4.6mm 250x4.6mm HC185-KS0346 $250 HC185-KS0546 $260 HC185-KS1046 $270 HC185-KS1546 $300 HC185-KS2546 $325 30x3.0mm 50x3.0mm 100x3.0mm 150x3.0mm 250x3.0mm HC185-KS0330 $250 HC185-KS0530 $260 HC185-KS1030 $270 HC185-KS1530 $300 HC185-KS2530 $325 30x2.1mm 50x2.1mm 100x2.1mm 150x2.1mm 250x2.1mm HC185-KS0321 $250 HC185-KS0521 $260 HC185-KS1021 $270 HC185-KS1521 $300 HC185-KS2521 $325 Semi-Prep and Prep Columns Kromasil 100 C8 5µm Kromasil 100 C18 5µm 10mm and 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HC085-KS0510 $475 HC085-KS1010 $500 HC085-KS1510 $650 HC085-KS2510 $900 50x20mm 100x20mm 150x20mm 250x20mm HC085-KS0520 $960 HC085-KS1020 $1200 HC085-KS1520 $1500 HC085-KS2520 $ mm and 20mm I.D. Stainless Steel Semi-Prep and Prep Columns 50x10mm 100x10mm 150x10mm 250x10mm HC185-KS0510 -$475 HC185-KS1010 $500 HC185-KS1510 $650 HC185-KS2510 $900 50x20mm 100x20mm 150x20mm 250x20mm HC185-KS0520 $960 HC185-KS1020 $1200 HC185-KS1520 $1500 HC185-KS2520 $2200 HAISpeed10-10mm I.D. Stainless Steel Cartridge Columns Kromasil 100 C8 5µm Kromasil 100 C18 5µm 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC085-KF0310 $250 HC085-KF0510 $295 HC085-KF1010 $370 10mm I.D. s.s. HAIspeed Cartridges 30x10mm 1/pkg 50x10mm 1/pkg 100x10mm 1/pkg HC185-KF0310 $250 HC185-KF0510 $295 HC185-KF1010 $370

35 KROMASIL 100 Ordering Information 3 HAICART - Stainless Steel Analytical Cartridge Columns Kromasil 100 C8 5µm Kromasil 100 C18 3.5µm Kromasil 100 C18 5µm 4.6 and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC085-KF0446 $260 HC085-KF0546 $270 HC085-KF1046 $260 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC085-KF0432 $260 HC085-KF0532 $270 HC085-KF1032 $ and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC183-KF0446 $260 HC183-KF0546 $270 HC183-KF1046 $260 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC183-KF0432 $260 HC183-KF0532 $270 HC183-KF1032 $ and 3.2mm I.D. s.s. Analytical Cartridges 40x4.6mm 2/pkg 50x4.6mm 2/pkg 100x4.6mm 1/pkg HC185-KF0446 $260 HC185-KF0546 $270 HC185-KF1046 $260 40x3.2mm 2/pkg 50x3.2mm 2/pkg 100x3.2mm 1/pkg HC185-KF0432 $260 HC185-KF0532 $270 HC185-KF1032 $260 HAIPEEK - PEEK Analytical Cartridge Columns Kromasil 100 C8 5µm Kromasil 100 C18 5µm 2.1mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC085-KK0421 $235 HC085-KK0521 $ mm I.D. PEEK Analytical Cartridges 40x2.1mm 2/pkg 50x2.1mm 2/pkg HC185-KK0421 $235 HC185-KK0521 $240 HAICART Guard Cartridges - 3.2mm I.D. Stainless Steel Kromasil 100 C8 5µm Kromasil 100 C18 5µm S.S. Guard Cartridges 20x3.2mm 5/pkg HK108 $165 S.S. Guard Cartridges 20x3.2mm 5/pkg HK118 $165 HAIPEEK Guard Cartridges - 2.1mm I.D. PEEK Kromasil 100 C8 5µm Kromasil 100 C18 5µm PEEK Guard Cartridges 20x2.1mm 5/pkg HC085-KK0221$170 PEEK Guard Cartridges 20x2.1mm 5/pkg HC185-KK0221$170

36 HAIPEEK and HAISpeed Holders for Guard, Analytical, SemiPrep and Prep Cartridges Leak-free operation without wrenches Wide range of lengths available - 2, 4, 5, 10cm Wide range of I.D.s available to 20mm Inert construction - no oxidation or galling Can be used with either s.s. or PEEK cartridges Direct column connection for guard cartridges No special tools required to extract cartridge HAIPEEK and HAISpeed Holders for Cartridge Columns The family of convenient cartridge holders from Higgins Analytical provides leak-free operation without requiring any tools. Their inert and robust design insures that the HAIPEEK and HAISpeed holders will not oxidize and their threads will never gall. Proven Seal Design The Holder s basic seal design is also used in many of the components of Higgins Analytical s highly automated column manufacturing equipment. Conditions used in HPLC column production often exceed the 10,000PSI pressure used for testing the HAIPEEK holder. And keep in mind that all this is achieved without having to tighten the assembly with wrenches! Knuckle Breaking Advice from the Net A well meaning chromatographer recently advised readers of a popular technical bulletin board on the Internet that his solution to the common problem of leaky guard holders from some manufacturers was to,...tighten the nuts until you think you are going to strip them. They never leak that way. Obviously this person had not yet tried a Higgins Analytical HAIPEEK holder! Format Flexibility The HAIPEEK holders are compatible with Higgins Analytical s PEEK guard and analytical cartridges as well our stainless steel HAICART guard cartridges. In addition, the stainless steel cartridges from several other manufacturers can also be used in these unique holders. Most applications benefit from the HAIPEEK Guard Holder s convenient a HAIPEEK Guard cartridge is used as a very short analytical column for fast separations. It also allows you to substitute a sample injection valve s sample loop with a HAIPEEK Holder, allowing guard cartridges to be used for sample enrichment applications. HAISpeed10 - A new, very high performance 10mm I.D. Cartridge System High throughput requiements for combinatorial chemistry applications often call for 10mm I.D. columns. Higgins Analytical has developed a convenient cartridge system that offers an economical solution for demanding combinatorial and semipreprative needs. Eventhough a HAISpeed10 cartridge costs a fraction of conventional 10mm HPLC column of the same length, they have the same consistantly high performance of other Higgins Analytical columns. HAISpeed20 - Unique Protection for 20mm I.D. prep columns Prep is a dirty business, and expensive columns can be quickly destroyed by crude samples if proper precautions are not taken. Higgins Analytical s HAISpeed20 Prep Guard System provides effective column protection without compromising performance. In addition to an efficiently packed bed which retains strongly absorbing junk that would change the selectivity of the prep column, these unique guard cartridges have 0.5µm frits that remove particulate contaminants as well. DO NOT USE HAISpeed HOLD- ERS FOR SFC and/or SFE APPLI- CATIONS! The HAISpeed10 and HAISpeed20 cartridge holders are rated for use up

37 Cartridge Holders 3 ability to connect directly to the HPLC column. A HAIPEEK Guard Holder having female fittings on both ends is also available, however. This symmetrical version (P/N HK-GUARD-FF) is called for when Heat Transfer Characteristics The thermal conductivity of the plastic materials in Higgins Analytical s cartridge holders (~0.15 BTU/(hr)(ft 2 )(ºF/ft) is one to two orders of magnitude smaller than aluminum (113) and stainless steel (~1,000) commonly used in other manufacturer s cartridge holders. Thermal equilibration rate measurements were made to determine how these differences in thermal conductivity would effect re-equilibration time after a temperature change. Experimental Results Relative temperature equilibration times for a Brownlee MPLC Holder and a Higgins HAIPEEK holder were determined chromatographically. A 40x3.2mm HAISIL 100 C18 5mm cartridge (P/N HM185- HF0432) was used for the analysis of fluorene in a 70% acetonitrile/water mobile phase at 420mL/min in both holder types. After determining the analyte s retention time at room temperature (21.7ºC), the assembly was placed in a forced air oven set to 35ºC. Retention time measurements were made at approximately two minute intervals until a steady state was reached. The figure to the right shows that rates for both holders were very similar, with equilibration being reached in a little less than 10 minutes. Notes Retention time precision was approximately minutes for these data. Oven temperature was measured to 0.1ºC. Oven temperature was 35.9ºC during the Higgins holder experiment. Temperature was 35.0ºC during the Brownlee holder experiment. HAIPEEK and HAISpeed Cartridge Holder Ordering Information HAIPEEK Guard Cartridge Holders These holders are compatible with Higgins HAICART and HAIPEEK guard cartridges. Direct-HConnect Holders Each kit includes a 10cm piece of PEEK tubing, a bushing and a ferrule. HHK-GUARD-FM HAIPEEK Guard Holder Kit (female/male) $150 HWK-GUARD-FM HAIPEEK Guard Holder Kit for Waters columns (female/male) $150 Symmetrical Connection Holders Each kit includes two 10cm pieces of PEEK tubing, two bushings, and two ferrules. HHK-GUARD-FF HAIPEEK Guard Holder Kit (female/female) $160 This holder has female fittings on both ends as pictured to the left. HAIPEEK 2.1, 3.2, and 4.6mm I.D. Analytical Cartridge Holders These holders are compatible with Higgins HAICART and HAIPEEK Analytical Cartridges. HHK-HOLD-40 HAIPEEK 40mm Cartridge Holder Kit $160 HHK-HOLD-50 HAIPEEK 50mm Cartridge Holder Kit $165 HHK-HOLD-100 HAIPEEK 100mm Cartridge Holder Kit $170 HAISpeed10 10mm I.D. SemiPrep Cartridge Holders These holders are compatible with Higgins HAISpeed10 Cartridges. H10-HOLD-30 HAISpeed10 30mm Cartridge Holder Kit $160 H10-HOLD-50 HAISpeed10 50mm Cartridge Holder Kit $165 H10-HOLD-100 HAISpeed10 100mm Cartridge Holder Kit $170 HAISpeed20 20mm I.D. Prep20 Guard Cartridge Holder This holder is compatible with Higgins Prep20 Guard Cartridges. H20-HOLD-25 HAISpeed20 20x25mm Cartridge Holder Kit $250

38 A simple, yet effective, means of protection is to place a filter in the flow path between the sample injection valve and the HPLC column. While this technique is commonly used, it is also commonly plagued by leaky holders and significant performance loss. The Higgins Analytical HAIFILTER resolves all of these problems! Simplicity and Convenience The Higgins Analytical HAIFILTER provides efficient and leak-free inline filtration, yet it does not require any tools. To make it even more convenient, the HAIFILTER is designed to connect directly to the inlet fitting on the HPLC column, maximizing performance, and minimizing hardware. The 0.5µm porosity frits will remove much of the particulate contamination that is largely responsible for column pressure build up and plugging. The holder s inert construction, and the availability of PEEK and titanium as well as stainless steel frits, insures that the HAIFILTER can address all of your inline filtration needs. needs....an ideal solution for high performance, in-line filtration Low cost, yet effective column protection Direct column connection and symmetrical versions No tools required Leak free operation 0.5µm filters in stainless steel, titanium or PEEK Inert construction s threads won t oxidize or gall Two Convenient Formats HAIFILTER is now available in two formats. The leak-free, finger-tight, and efficient performance are qualities of the HAIFILTER that have made it a popular product, replacing the competition s awkward and leaky alternatives in hundreds of laboratories worldwide. The direct- HConnect feature in the original design makes the HAIFILTER FM ideal for protecting HPLC columns while the symmetrical female thread fittings on each end of HAIFILTER FF provide unequaled flexibility to address your HPLC system s filtration requirements.

39 HAIFILTER 3 HPLC Columns without a HAIFILTER N=24,664 N=19, x4.6mm (P/N LS-2546-HC185) Performance Try the experiment summarized by the chromatograms above with another manufacturer s in-line filter. You may be very surprised how much more other in-line filters contribute to peak broadening when comparison to the miniscule 28mL 2 at 200mL/min HPLC Columns with a HAIFILTER N=24, x4.6mm (P/N LS-2546-HC185) 250x2.1mm (P/N HS-2546-HM185) N=17, x2.1mm (P/N HS2546-HM185) volume-variance that is obtained with the HAIFILTER. This exceptional efficiency is confirmed by chromatographers reporting that using a HAIFILTER permits the routine analysis of solid-phase sample extracts by LC/MS with good efficiency and greatly enhanced HPLC column life. FILTER replacement is easy and requires no tools Flexibility Not only is the HAIFILTER available in two formats, it can also be directly connected to a sample injection or switching valve. The photograph to the right demonstrates how the HAIFIL- TER has been designed to clear the bushings on a popular Rheodyne sample injection valve. HAIFILTER Ordering Information HAIFILTER FM (Female/Male) Starter Kits HHF-FKIT HAIFILTER FM (Standard) $200 HHF-WKIT HAIFILTER FM (for Waters HPLC columns) $200 HHF-RKIT HAIFILTER FM (for Rheodyne injection valves - $200 Specify valve model when ordering) Note: HAIFILTER FM Starter Kits include a package of 10 filters (HHF-SFILT), a 10cm piece of PEEK tubing, and a Delrin bushing and a PEEK ferrule. HAIFILTER FF (Female/Female) Starter Kit HFF-FKIT HAIFILTER FF $200 Note: The HAIFILTER FF Starter Kit includes a package of 10 filters (HHF- SFILT), two 10cm pieces of PEEK tubing, and two Delrin bushings and two PEEK ferrules. Replacement Filters All replacement kits contain 10 filters per package HHF-SFILT Stainless steel HAIFILTER replacement filters (pkg of 10) $40 HHF-TFILT Titanium HAIFILTER replacements filters (pkg of 10) $75 HHF-PFILT PEEK HAIFILTER replacements filters (pkg of 10) $90

40 The HAIGUARD Holder and Guard- Disc System consists of a high pressure holder and a small disc of chromatographic sorbent contained in an inert polymer matrix. This compact package is easily connected directly to your analytical HPLC column providing an economical approach for enhancing column lifetime. Leak Free The HAIGUARD Holder s novel seal design assures leak-free operation. While the is rated at 4,000 PSI, the HAIGUARD Holder has undergone destructive testing at more than 10,000 PSI higher pressure than most instruments can even generate. While we don t recommend doing chromatography under conditions that would result in such high pressures, it is comforting to know that none of the HAIGUARD Holders tested experienced a leak. HAIGUARD Holder and Guard-Disc System Easy visual monitoring for contamination 0.2µm porosity Leak-free operation No tools required Inert construction - no oxidation or galling Economical - fraction of conventional guard cost 10x s the pore density of sintered filter materials Higgins Analytical provides chromatographers with a new concept in HPLC guard column technology. For the first time, users can protect their analytical HPLC column s from both chemical and particulate contamination with a device that does not interfere with the analytical column s chromatographic process. The ability to periodically inspect HAIGUARD for contamination is a further example of this product s uniqueness. No Tools Required One of the first things you will notice is that there is no knurling on the HAIGUARD Holder. Holder installation and Guard-Disc changes are accomplished without any tools. And, the reliable, leak-free performance, even under the challenging operating conditions used on some of today s modern HPLC columns, is achieved with only the slightest finger-tight torque during holder assembly. There is no more need to tear apart the lab looking for the 1/4 wrench that s never where you left it. Inert Construction The Holder is machined from a high

41 HAIGUARD 3 density PEEK extrusion. This provides not only a rugged design, but it also assures chemical inertness to commonly used HPLC solvents and buffer systems. This is especially important in applications where biocompatibility is a concern or electrochemical detection is involved. The HAIGUARD Holder and Guard-Disc System is the perfect complement to your biocompatible HPLC system and PEEK HPLC columns. Another advantage is that the PEEK threads will never gall or corrode as they do on many manufacturers guard holder designs. Visual Contamination Checks One of the biggest issues with guard column use is the uncertainty about when it should be changed. A recently published survey indicated that the typical user changes a guard column very few times throughout the analytical column s lifetime. One reason for this poor practice is that, except for back pressure build up, most indications of guard column failure come long after the analytical column has been damaged. With a Guard-Disc, a more rational approach can be taken. The Guard-Disc s unique design makes it the only HPLC column guard system that is capable of being visually inspected on a periodic basis. The Holder can be quickly opened to inspect the top surface of the disc for contamination, particles, or discoloration. Symmetrical Version for strength and flexibility. HAIGUARD is available in a symmetrical format with female fittings on each end. This version is a solution to situations where space constraints or instrument plumbing requirements don t call for the ability to directly couple the HAIGUARD to an HPLC column. Specifications Materials: The HAIGUARD Holder is made of PEEK (polyetherether ketone) and its components contain Teflon, 316 stainless steel, and titanium. The 1/16 tubing and ferrule are PEEK, and the finger-tight fitting are made of PEEK or acetal plastic. The Guard- Disc s sorbent is contained in a polymer matrix held in a PEEK ring assembly. Temperature and Pressure: Maximum recommended operating temperature is 80ºC. The maximum operating pressure is limited by the plastic bushing and ferrule which is approximately 4,000 PSI (275 BAR). Solvents: The Holder has very good chemical resistance to most commonly used HPLC solvents and buffer systems. DMSO, Me 2 Cl 2, and THF can cause PEEK to swell over a period of time, so they are not recommended for routine use. The Disc s characteristics are outlined in the table below. The C18B discs exhibit slightly chromatographic performance than the C18A type, but they should not be used with chlorinated solvents. Volume Variance: The Holder and Disc s contribution to an HPLC system s total system volume variance is about 20mL 2 at 200mL/min, so under isocratic conditions, some performance loss can be experienced with columns with I.D. s smaller than 4.6mm. HAIGUARD Ordering Information Holder Kits (female/male): HGD-GKIT HAIGUARD Holder with GD- HC18B discs (pkg of 10), 10cm $300 PEEK Tubing, Delrin bushing and PEEK ferrule. HGD-HOLD GD-KIT without Guard-Discs. $150 HGD-WKIT Same as GD-GKIT but having tube-stop depth compatible with $300 Waters HPLC columns. HGD-HOLW GD-WKIT for Waters HPLC columns (without Guard-Discs). $150 Holder Kit (female/female): HGF-GKIT HAIGUARD Holder with female fittings on each end. $310 Includes GD-HC18B discs (package of 10), two lengths of 10cm PEEK tubing, two Delrin bushings and two PEEK ferrules. HGF-HOLD HAIGUARD Holder with female fittings on each end. $160 (without Guard-Discs). HAIGUARD Guard Disc Refills (packages of 10 discs): HGD-HC18A ODS (Optional Teflon, 0.2mm porosity (pkg of 10) $160 HGD-HC18B ODS (Standard PVC, 0.8mm porosity (pkg of 10) $160 HGD-SDVB Styrene divinylbenzene, 0.2mm porosity (pkg of 10) $160 HGD-AION Anion Exchange, 0.2mm porosity (pkg of 10) $160

42 Part Numbering Scheme, Custom Services, and Acknowledgem We Violate the 80:20 Rule This catalog contains hundreds of parts and it would probably be no surprise to you if we pointed out that only about 20% of them are manufactured 80% of the time. But what you would not know is that another 20% of the products we manufacture are not even listed in this catalog! We stock tubing with a wide variety of internal diameters, and since we machine the columns and cartridges ourselves, custom length and I.D. columns are almost as easy for us to provide as are the standard sizes listed in this catalog. Since our part numbering system has an easy to understand pattern, customers routinely compose and order custom configurations. Easy to Understand Part Numbers Except for HAICART Guard Cartridges, all Higgins Analytical HPLC column product part numbers are based on a character pattern. While we will not manufacture every combination and permutation devisable with this scheme, this page will serve as a guide to assist you in defining a product that you believe would better address your needs than one of the hundreds of formats we routinely manufacture. The two character prefix indicates sorbent and hardware type. Standard configurations are highlighted. Suffix Character 1 (Sorbent) XXXXX-nXXXXX C = CLIPEUS H = HAISIL 100 or HAISIL 300 K = Kromasil L = HAISIL HL T = TARGA Suffix Character 2 (Hardware) XXXXX-XnXXXX S = Stainless steel HPLC Column P = PEEK HPLC column F = Stainless steel cartridge column K = PEEK cartridge column N = Nano Scale column ( 150µm) The four center characters indicate the column or cartridge length (cm) and internal diameter (mm). Prefix Characters 3 and 4 (Length) XXXXX-XXnnXX 03 = 3cm 04 = 4cm 05 = 5cm 07 = 7.5cm 10 = 10cm 12 = 12.5cm 15 = 15cm 20 = 20cm 22 = 22cm 25 = 25cm 30 = 30cm 50 = 50cm Suffix Characters 5 and 6 (I.D.) XXXXX-XXXXnn 15 = 150µm M3 = 300µm M5 = 500µm M8 = 800µm 01 = 1.0mm 21 = 2.1mm 30 = 3.0mm 32 = 3.2mm 40 = 4.0mm 46 = 4.6mm 10 = 10mm 20 = 20mm M2 = 0.17mm The four character suffix indicates sorbent chemistry and particle size. Prefix Characters 1 to 4 (Phase) nnnnx-xxxxx HC04 = Butyl or C4 HC08 = Octyl or C8 HC18 = ODS or C18 HCNP = Cyano or Nitrile HM08 = HAISIL 100 C8 HM18 = HAISIL 100 C18 HNH2 = Amino HPHN = Phenyl HSIL = Silica Gel HW04 = 300Å C4 HW08 = 300Å C8 HW18 = 300Å C18 Suffix Character 5 (Particle Size) XXXXn-XXXXXX 1 = 10µm 2 = 10-15µm 3 = 3 or 3.5µm 5 = 4.5 or 5µm 7 = 15-20µm Custom HPLC Columns Let us or your local distributor know if you have particular needs or are interested in formats or chemistries not listed in this catalog. Higgins Analytical is continuously developing new products and would be interested in discussing your individual requirements. We are also able to pack your own sorbents into analytical or semiprep columns enabling you to conduct selectivity tests and separation optimization work before you commit your sample to very large scale columns packed with the same material. Higgins is grateful to the following individuals for permission to share their data in this catalog: Jane Cooper, Lilly Research, Erl Wood Manor, Windlesham, Surrey UK In Vivo Microdialysis Samples from Rat Hypothalamus. Page 27 Larry David, Oregon Health Sciences University, School of Dentistry, Portland, OR Human Ocular Lens Protein (Beta A1 Crystallin and Gamma S Crystallin) Analysis by LC/MS. Page 29 Chris Gong and Chulani Karunatilake, Genentech, Inc., South San Francisco, CA Fast Peptide map of rhgh on a 5cm column. Page 17 Elizabeth Harris, Emisphere Technologies, Inc., Hawthorne, NY Fast Analysis a Drug Delivery System. Page 17 David Hawke, Perseptive Biosystems, Western Technical Center, South San Francisco, CA Fast Tryptic Map of Cytochrome-C. Page 17 Ted Holman, University of California, Santa Cruz, CA Large Competitive Kinetic Isotope Effects in Human 15-Lipoxygenase Catalysis Measured by a Novel HPLC Method. Page 11 David Isom, Analytical Sales and Service, Pompton Plains, NJ Fat-Soluble Vitamin Assay. Page 27 Antibacterials. Page 27 Antihypertensives. Page 29 Krishna Kalghatgi, NeoGenesis, Cambridge, MA RPC of Basic Compounds in Combinatorial Mixtures. Page 23 Kamlesh Patel, University of North Carolina, Department of Chemistry, Charlottesville, VA Analysis of Basic Peptides and Peptide Mapping without TFA. Page 27 Mark Ross, Argonex, Inc., Charlottesville, VA Micropreparative Chromatography and Reanalysis of Peptides from Tumor Cells. Page 17 Steve Sharp, Roche Products, Welwyn Garden City, UK LC/MS of Serum Samples. Page 23 Lorne Vandermark, Pharmco, Titusville, FL Analysis of Cat s Claw Extract. Page 11

43 Technical Support, Purchasing, and Warranty Expert and Responsive Technical Support As a Higgins Analytical Customer seeking technical support or product information, you will eliminate long waits and expensive phone calls, and you will never be transferred from one person to another only to end up in someone s phone mail! By simply faxing ( US and Canada) or ing (hplc@western lanalytical.com) Technical Support Group, you will receive a prompt written response. If we don t know the answer, we will tell you so but, that doesn t happen very often. Additional up-to-date product and application information can be found by pointing your browser at our web site. Supply.com Easy Ordering and Rapid Delivery Our catalog-listed items are generally shipped from the factory within a day of receiving the order. In the event that we have not provided you with a nearby distributor, we can ship an order to you directly from the factory by a variety of carriers. In order to further simplify the process for you and your purchasing department, Western Analytical Products accepts credit cards for orders. Payment terms for all other orders are net 30 days from date of invoice. Product Availability Higgins Analytical products are available worldwide through a network of responsive distributors. These organizations can provide qualified technical support and prompt product delivery. The names can be found by sending us a fax ( ) or by checking our web site which, in addition to names, addresses and phone numbers, contains many hyperlinked and URL addresses. HIGGINS ANALYTICAL PRODUCTS MAY BE PURCHASED AND ARE SOLD ONLY ON THE FOLLOWING WARRANTY TERMS AND CONDI- TIONS. ADDITIONAL OR DIFFERENT TERMS, WHETHER IN AN ORDER, ACKNOWLEDGMENT, INVOICE OR OTHER DOCUMENT, SHALL NOT BECOME PART OF OR VARY THE FOLLOWING TERMS UNLESS AGREED TO IN WRITING BY HIG- GINS ANALYTICAL. LIMITED WARRANTY Higgins Analytical products are manufactured and quality controlled to the highest industry standards, and Higgins Analytical warrants that the products, when properly applied in accordance with Higgins Analytical's standards therefor, will perform for a period of thirty (30) days after delivery substantially as described in Higgins Analytical's then current specifications for the product. If a customer believes a product does not comply with such warranty, the customer shall, within the warranty period, report the purported defect to Higgins Analytical and cooperate fully with Higgins Analytical in determining the conditions and cause of any purported defect and, thereby, obtain a returned goods authorization from Higgins Analytical or the place of purchase. If Higgins Analytical determines the alleged defect occurred as a result of misuse, neglect, improper installation, repair, alteration, application or accident, rapid depressurization, removal of column end fittings, unusual physical or electrical stress or improper handling procedure, the warranty shall be void and ineffective. EXPRESS LIMITATIONS HIGGINS ANALYTICAL PRODUCTS ARE MANUFACTURED FOR USE IN RESEARCH IN CHEMICAL MANUFAC- TURING LABORATORIES ONLY AND ARE NOT INTENDED FOR USE IN CLINICAL OR DIAGNOSTIC APPLICA- TIONS. THE HAISPEED10 AND HAI- SPEED20 CARTRIDGE HOLDERS ARE RATED FOR USE UP TO 3,000 PSI (200BAR) WITH FLUIDS THAT ARE LIQUID AT STP (STANDARD TEMPERATURE AND PRESSURE) ONLY. SERIOUS BODILY INJURY OR DEATH MAY RESULT IF A HAISPEED HOLDER BROKE WHILE WORKING WITH SUPERCRITICAL FLUIDS. DISCLAIMER EXCEPT AS EXPRESSLY PROVIDED, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS, INDEMNITIES AND GUARANTEES, WHETHER EXPRESS OR IMPLIED, ARISING BY LAW, CUSTOM, PRIOR ORAL OR WRITTEN STATEMENTS BY HIGGINS ANALYTICAL OR OTHERWISE (INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY FOR MER- CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) ARE OVER- RIDDEN, EXCLUDED AND DIS- CLAIMED. EXCLUSIVE REMEDY In the event a customer establishes a breach of the above warranty, customer's exclusive remedy against Higgins Analytical, and Higgins Analytical's sole liability, is, at its option, the replacement of the defective product or the refund of the purchase price therefor. NO CONSEQUENTIAL DAMAGES HIGGINS ANALYTICAL SHALL NOT BE RESPONSIBLE FOR ANY CONSE- QUENTIAL, INDIRECT, SPECIAL, PUNITIVE OR INCIDENTAL DAM- AGES, WHETHER FORESEEABLE OR UNFORESEEABLE, INCLUDING, BUT NOT LIMITED TO, CLAIMS FOR LOSS OF GOODWILL, PROFITS, USE OF MONEY OR USE OF PRODUCTS, STOPPAGE OF OTHER WORK OR IMPAIRMENT OF OTHER ASSETS, ARISING OUT OF BREACH OF EXPRESS OR IMPLIED WARRANTY, BREACH OF CONTRACT, MISREPRE- SENTATION, NEGLIGENCE, STRICT LIABILITY IN TORT OR OTHERWISE, EXCEPT ONLY IN THE CASE OF PER- SONAL INJURY WHERE AND TO THE EXTENT THAT APPLICABLE LAW REQUIRES SUCH LIABILITY. PATENTS AND TRADEMARKS Kromasil is a trademark of Eka Nobel. NewGuard and MPLC are trademarks of Perkin-Elmer. PICOTAG is a trademark of Waters. HAISIL, HAICART, HAIPEEK, HAIFILTER, TARGA, CLIPEUS, HAISpeed, and HAIGUARD are trademarks of Higgins Analytical, Inc. Guard-Disc is a trademark of

44 CLIPEU Higgins Analytica HAISIL 300 HAISIL 100 TARGA Kromasil HAISIL HL Higgins Analytical products are sold and supported by Western Analytical P.O. Box 579, Murrieta, CA USA Telephone Facsimile Internet

CLIPEUS - A Small Shield for a Big Job

CLIPEUS - A Small Shield for a Big Job CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,

More information

E X P E RT M A N U F A C T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014

E X P E RT M A N U F A C T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014 E X P E RT M A N U FAC T U R E R O F H P L C C O N S U M A B L E S Higgins Analytical 2014 WO R L DW I D E AVA I L A B I L I T Y A N D S U P P O RT Higgins Analytical is a quality oriented company, dedicated

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S. Higgins Analytical

E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S. Higgins Analytical E X P E RT M A N U FAC T U R E R S O F H P L C C O N S U M A B L E S Higgins Analytical 2008 C O N T E N T S HIGGINS ANALYTICAL 2-3 HPLC COLUMNS 24-29 CLIPEUS 4-5 MICROBORE COLUMNS 30-37 HAISIL 100 6-7

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience. Pure Consumables More focus on your application The Pure consumable portfolio offers an unrivaled range of products

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

Gemini-NX Performance paired with Axia Technology

Gemini-NX Performance paired with Axia Technology Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters Application Angelika Gratzfeld-Huesgen Abstract This application has been verified using an Agilent

More information

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles Stephanie Schuster 1, Barry Boyes 1,2, and Darryl Johnson 2 1 Advanced Materials Technology,

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

MODERN HPLC FOR PRACTICING SCIENTISTS

MODERN HPLC FOR PRACTICING SCIENTISTS MODERN HPLC FOR PRACTICING SCIENTISTS Michael W. Dong Synomics Pharmaceutical Services, LLC Wareham, Massachusetts WILEY- INTERSCIENCE A JOHN WILEY & SONS, INC., PUBLICATION Preface xv 1 Introduction 1

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

SGE is excited to launch a new HPLC product line under the ProteCol brand.

SGE is excited to launch a new HPLC product line under the ProteCol brand. The Role of Pore Size in Reversed Phase HPLC SGE is excited to launch a new HPLC product line under the ProteCol brand. Fundamental to the new ProteCol line of columns is the continued focus on inert column

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

Separation of Structurally Similar Steroids on HALO C18 and PFP

Separation of Structurally Similar Steroids on HALO C18 and PFP Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm,

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Agilent Bond Elut Plexa vs. Waters Oasis Sample Prep Products Reliability is a key parameter in developing rugged,

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application Food Author Michael Woodman Agilent Technologies, Inc. 285 Centerville Road Wilgton, DE 1988-161 USA Abstract Soft drinks,

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

Peptide Isolation Using the Prep 150 LC System

Peptide Isolation Using the Prep 150 LC System Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System, an affordable, highly reliable system for preparative chromatography, is suitable

More information

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion

More information

Biochemistry. Biochemical Techniques HPLC

Biochemistry. Biochemical Techniques HPLC Description of Module Subject Name Paper Name 12 Module Name/Title 13 1. Objectives 1.1. To understand the basic concept and principle of 1.2. To understand the components and techniques of 1.3. To know

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

LC Column Troubleshooting. Do you have an equivalent column for my LC column? LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there

More information

IN QUALITATIVE ANALYSIS,

IN QUALITATIVE ANALYSIS, IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS UCT Part Numbers: CSFASETG203 - CLEAN SCREEN FASt ETG, 200mg / 3mL tube SLETG100ID21-3UM - Selectra ETG HPLC column, 100 x 2.1

More information

Quality control analytical methods- Switch from HPLC to UPLC

Quality control analytical methods- Switch from HPLC to UPLC Quality control analytical methods- Switch from HPLC to UPLC Dr. Y. Padmavathi M.pharm,Ph.D. Outline of Talk Analytical techniques in QC Introduction to HPLC UPLC - Principles - Advantages of UPLC - Considerations

More information

Epic Aromatic Selectivity

Epic Aromatic Selectivity Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis Comparing Columns from Different Vendors to Improve Data Quality Technical Overview Introduction Size exclusion chromatography

More information

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions Today, ultra-high-performance liquid chromatography (UHPLC) has taken a firm foothold in the analytical laboratory.

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

UPLC for Synthetic Peptides: A User`s Perspective

UPLC for Synthetic Peptides: A User`s Perspective Tides 2007 Conference Las Vegas, May 23, 2007 UPLC for Synthetic Peptides: A User`s Perspective Holger Hermann, Jens Donath* Lonza AG, Switzerland Welcome to Lonza! One of the leading CMO Production facilities

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

UPLC Method Development and Validation

UPLC Method Development and Validation UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy

More information

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents GPC-/SEC-Columns & 2 accessories2 0 18 direct from Producer packed in new generation column hardware! MZ-Gel SD MZ-Gel SD LS MZ-Super FG Development Manufacturing Distribution Consulting HPLC-Columns New

More information

C18 Column. Care & Use Sheet

C18 Column. Care & Use Sheet C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin

More information

PolyHYDROXYETHYL Aspartamide for Hydrophilic Interaction Liquid Chromatography(HILIC)

PolyHYDROXYETHYL Aspartamide for Hydrophilic Interaction Liquid Chromatography(HILIC) PolyHYDROXYETHYL Aspartamide for Hydrophilic Interaction Liquid Chromatography(HILIC) Hydrophilic Interaction Liquid Chromatography(HILIC) is a variant of normal-phase chromatography which can be performed

More information

1.7µm Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency

More information

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com

More information

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry Jon Hao, Rong Ye, and Mason Tao Poochon Scientific, Frederick, Maryland 21701 Abstract Background:

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

HPLC Winter Webinars Part 2: Sample Preparation for HPLC HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do

More information

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chemistry Instrumental Analysis Lecture 37. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 37 Most analytes separated by HPLC are thermally stable and non-volatile (liquids) (unlike in GC) so not ionized easily by EI or CI techniques. MS must be at

More information

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput MAY 2005 SEPARATION SCIENCE REDEFINED 31 Assay Transfer from HPLC to UPLC for Higher Analysis Throughput A typical HPLC assay was transferred and optimized for a Waters ACQUITY UPLC system to achieve both

More information

Sample Preparation TLC Plates

Sample Preparation TLC Plates TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,

More information