1 Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent up to 00% for elution of hydrophobic cations and column cleaning. Compatible with conductivity and UV detectors. One particle size: 0 µm. Six column internal diameters:.0 to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Monovalent Cations Glycine and Ethanolamine N-Methylglucamine PRP-X00,. x 0 mm (P/N 79). Lithium. Sodium. Ammonium. Potassium. Cesium PRP-X00,. x 0 mm (P/N 79). Glycine. Sodium. Ethanolamine PRP-X00,. x 0 mm (P/N 79). N-Methylglucamine mg/ml 0 0 Conditions:.: mm Nitric Acid: Methanol. Isocratic. Ambient. ml/min. 00 µl, Conductivity. 0 6 Conditions: mn Nitric Acid. Ambient. Isocratic. ml/min. 0 µl, Conductivity. 0 8 Conditions: mn Nitric Acid. Isocratic. Ambient. ml/min. µl, Conductivity. I.D. x Length 0 µm I.D. x Length 0 µm.0 x 0 mm x 0 mm 79.0 x 00 mm x 0 mm 79.0 x 0 mm x 0 mm* 79.0 x 0 mm x 0 mm* 798. x 0 mm x 0 mm* 797. x 0 mm x 0 mm x 00 mm x 0 mm 799 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) Semiprep/Preparative Guard Column Starter Kits ( holder, cartridge) 797 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 m *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns*** 0

2 PRP-X00 Cation Exchange Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water. Faster analysis when compared to competitor s columns. Detection levels of less than 0 ppb when using the post column, OPA derivatization technique. Applicable to other separations, such as inositol and sugar alcohols. Two particle sizes: 7 and -0 µm. Five column internal diameters:. to. mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Glyphosate and Metabolite Inositol in Vitamin Matrix Sugar Alcohols PRP-X00,. x 0 mm, 7 µm (P/N 797). Glyphosate. Aminomethylphosphonic Acid PRP-X00,. x 0 mm, 7 µm (P/N 797),,, and. Unknown. Inositol PRP-X00,. x 0 mm, 7 µm (P/N 797). Adonitol 00 ppm. Arabitol 00 ppm. Xylitol 00 ppm. Mannitol 00 ppm. Sorbitol 00 ppm 0 6 Conditions: 0.00M Monobasic Potassium Phosphate. Isocratic. Ambient. 0. ml/min. 00 µl, Excitation wavelength 8 nm. Emission wavelength nm. Post Column Conditions: Oxidation Solution Flow Rate: 0.0 ml/min; Reaction Coil: ml (0.0 cm ID X m); Reaction Time:. min; Temp: 8 C Derivatization Solution: 0.0 ml/min; Reaction Coil: 0.0 ml (0.0 cm ID X m), Ambient. Conditions: 8: Acetonitrile : 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 00 µl, Pulsed Amperometric Dual Gold Electrode. E=00 mv T=76 msec E=000 mv T=66 msec E=-800 mv T=99 msec Post Column Conditions: 0.N Sodium Hydroxide solution at ml/min Conditions: A) Acetonitrile; B) Water. Linear Gradient 0-0% B in 0 min. Ambient. ml/min. µl, Pulsed Amperometric Dual Gold Electrode; delay 0 msec E=00mV T=70msec E=000mV T=0msec E=-800mV T=00msec Post Column Conditions: 0.N Sodium Hydroxide at ml/min. I.D. x Length 7 µm -0 µm. x 0 mm x 0 mm x 0 mm x 0 mm x 0 mm* x 0 mm 797. x 0 mm 79 Analytical Guard Column Starter Kit ( holder, cartridges) 7976 Replacement Cartridges (/pk) 7977 C8 Guard Column for EPA Glyphosate Application Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 79 PRP-X00 Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 79 Replacement Cartridges (/pk) 79 * Analytical guard column for PEEK columns is.0 x 8.0 m ** Analytical guard column for steel columns is. x 0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For PEEK Columns* For Steel Columns** For Steel Columns***

3 PRP-X800 Cation Exchange Polymeric cation exchange columns for the isocratic separation of mono and divalent cations. Isocratic separation of lithium, sodium, ammonium, potassium, magnesium and calcium. Gradient separation of transition metals. Excellent durability (stable to any concentration of water or organic solvent). One particle size: 7 µm. Two column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in 6 stainless steel and PEEK. Mono and Divalent Cations Transition Metals Transition Metals PRP-X800,. x 0 mm, 7 µm (P/N 7988). Lithium ppm. Sodium ppm. Ammonium ppm. Potassium ppm. Magnesium ppm 6. Calcium ppm 0 6 Conditions: mm Cupric Sulfate. Isocratic. Ambient. 0.8 ml/min. 0 µl, Indirect UV 0 nm. 6 PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Cadmium 6 ppm. Zinc 6 ppm. Cobalt 6 ppm Conditions: A) 0mM Ammonium Acetate. ph.; B) Trifluoroacetic Acid in Water ph.. Linear Gradient -% B in 0 min. ml/min. 00 µl, Post Column Reaction: 0.0% -(-pyridylazo)resorcinol in M Ammonium Hydroxide 0. ml/min. Visible 0 nm. PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Zinc 6 ppm. Cadmium 6 ppm. Lead 6 ppm Conditions: A). mm Ethylenediamine ph.; B) 00mM Ethylenediamine ph.7. Linear Gradient 00% A (0- min.), 0-00% B in (-0 min.) ml/min, 00 µl, Post Column Reaction: 0.0% -(-pyridylazo) resorcinol (PAR) in M Ammonium Hydroxide, 0. ml/min. Visible 0 nm. I.D. x Length 7 µm. x 0 mm 798. x 0 mm x 0 mm* x 0 mm* 7989 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.

4 HC-0 Cation Exchange Polymeric % cross-linked soft-gel column for cation, ligand exchange separation of carbohydrates. Separate oligosaccharides up to DP8. Water mobile phase. Compatible with RI detectors. One particle size: 0 - µm. One column internal diameter: 7.8 mm. One column material: 6 stainless steel. Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79) 76. Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltooctaose + High Conversion Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79). Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltoheptaose Conditions: Water. Isocratic. 80 C. 0.6 ml/min. µl, Refractive Index Conditions: Deionized Water. Isocratic. 80 C. 0.6 ml/min. 0 µl, Refractive Index. Guard Columns For Steel Columns* Gel-Type Cation Exchange Column I.D. x Length 0- µm 7.8 x 0 mm 79 Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-0 guard column for steel columns is.6 x 0 mm

5 HC-7 Cation Exchange Polymeric 7.% cross-linked soft-gel columns for cation, ligand exchange separations of carbohydrates. Compatible with UV and RI detectors. Hydrogen form columns for USP L7 applications. Calcium form columns for USP L9 applications. Lead form columns for USP L applications. One particle size: 9 µm. Three column internal diameters:., 7.8 and 0.0 mm. One column material: 6 stainless steel. Three forms: calcium, lead and hydrogen. Malic Acid Citric, Lactic and Acetic Acids Dihydroxyacetone HC-7,. x 0 mm H + (P/N 7976). Maleic Acid ppm. Malic Acid 000 ppm. Fumaric Acid 0 ppm HC-7,. x 0 mm H + (P/N 7976). Citric, Acid 0 ppm. Lactic Acid 0 ppm. Acetic Acid 0 ppm HC-7, 7.8 x 0 mm Ca + (P/N 796). Formic Acid 0. mg/ml. Glycerol 0. mg/ml. Dihydroxyacetone 0. mg/ml 0 0 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 6 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 0 Conditions: 0.0M Calcium Chloride. Isocratic. 90 C. 0.6 ml/min. ul, Refractive Index. Gel-Type Cation Exchange Columns 9 µm, 9 µm, 9 µm, I.D. x Length Calcium Lead Hydrogen. x 0 mm x 00 mm x 0 mm x 0 mm 798 Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Guard Columns Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-7 guard column for steel columns is.6 x 0 mm For Steel Columns*

Anion Exchange HPLC Columns

Anion Exchange HPLC Columns Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

HPLC COLUMNS. HPLC Columns & Bulk Resins THE MEASURE OF EXCELLENCE TM

HPLC COLUMNS. HPLC Columns & Bulk Resins THE MEASURE OF EXCELLENCE TM HPLC COLUMNS & Bulk Resins THE MEASURE OF EXCELLENCE TM The Measure of Excellence Hamilton For nearly 0 years, Hamilton Company has been satisfying customer needs in the field of precision fluid measuring.

More information

HPLC. Columns and Resins. For a Complete Range of Applications

HPLC. Columns and Resins. For a Complete Range of Applications HPLC Columns and Resins For a Complete Range of Applications 0 HPLC COLUMNS AND RESINS HAMILTON Polymeric and Silica-Based Packings for a Complete Range of HPLC Separations To order products from this

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

IC Columns Introduction

IC Columns Introduction IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

HPLC Columns and Accessories. Solutions for liquid chromatography

HPLC Columns and Accessories. Solutions for liquid chromatography HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance

More information

HPLC Columns and Accessories. Solutions for liquid chromatography

HPLC Columns and Accessories. Solutions for liquid chromatography HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS17-C Anion Exchange Column columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

IC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories

IC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories IC Section IC Columns..............................304-316 Introduction..............................305-306 Allsep Anion Columns...................... 307 Novosep Anion Columns.................... 308

More information

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0

More information

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WAX-1 Columns User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N ) PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N 042195) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N 042191) QUICKSTART STEPS AND LINKS Click blue text below to get started.

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

Flow Solution FS 3700 Automated Chemistry Analyzer

Flow Solution FS 3700 Automated Chemistry Analyzer Method Abstract Total Cyanide by ISO 14403 Document #42600116 Flow Solution FS 3700 Automated Chemistry Analyzer Total Cyanide by In-Line Ultraviolet Digestion, Gas Diffusion, and Photometric Detection,

More information

Chemistry 20 Final Review Solutions Checklist Knowledge Key Terms Solutions

Chemistry 20 Final Review Solutions Checklist Knowledge Key Terms Solutions Chemistry 20 Final Review Solutions Checklist Have you mastered the concepts, applications, and skills associated with the following items? Check them off when you are confident in your understanding.

More information

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC The Analysis of rganic Acids in Foods and Beverages Using Reversed Phase HPLC Rebecca E. Wittrig & Terrence S. Reid Restek Corporation Benner Circle, Bellefonte, PA 683 USA Restek Corporation www.restekcorp

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

High-Performance Chromatography Superior isocratic separation of

High-Performance Chromatography Superior isocratic separation of columns I o n P a c C S A C a t i o n - E x c h a n g e C o l u m n The IonPac CSA cation-exchange column provides fast analysis of mono- and divalent cations, ammonium, and aliphatic amines simultaneously

More information

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System Application Update 55 Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free System Introduction Hydrogen peroxide is an essential chemical in the fabrication

More information

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

excellent performance spherical and sharp particle size distribution persistence and highest quality

excellent performance spherical and sharp particle size distribution persistence and highest quality ISO 00 Certified Working to enhance quality management excellent performance spherical and sharp particle size distribution persistence and highest quality offeres packing materials and packed, under strict

More information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Magnetic Flowmeter Material Selection Guide

Magnetic Flowmeter Material Selection Guide Magnetic Flowmeter Material Selection Guide www.sparlinginstruments.com Introduction The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter.

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium

More information

Saccharides and Organic Acids

Saccharides and Organic Acids Saccharides and Organic Acids Contents Introduction... 2 Reducing Sugars... 2 HILIC The HILICpak and Ashipak Series... 3 Shodex HILIC Columns for Sugar Analysis... 7 Ligand Exchange Shodex SUGAR series...

More information

Supramolecular chemical shift reagents inducing conformational transition: NMR analysis of carbohydrate homooligomer mixtures

Supramolecular chemical shift reagents inducing conformational transition: NMR analysis of carbohydrate homooligomer mixtures Electronic Supplementary Material (ESI) for ChemComm. This journal is The Royal Society of Chemistry 2015 Supramolecular chemical shift reagents inducing conformational transition: NMR analysis of carbohydrate

More information

Nomenclature Naming Ionic Compounds Worksheet #1

Nomenclature Naming Ionic Compounds Worksheet #1 Naming Ionic Compounds Worksheet #1 In forming ionic compounds with non-metals, the transition metals often exhibit more than one valence. For example, in the reaction between iron and chlorine, two products

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ]. BRIEFING Propylparaben. The European Pharmacopoeia is the coordinating pharmacopeia for the international harmonization of the compendial standards for the Propylparaben monograph, as part of the process

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

IC5000 Ion Chromatography System

IC5000 Ion Chromatography System IC000 Ion Chromatography System Quaternary gradient pumping and on-line eluent preparation to improve separations in complex samples In-line sample filtration to 0.8 µm to eliminate manual filtrations

More information

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,

More information

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min. Atorvastatin Calcium Tablets Type of Posting Posting Date 25 Jan 2019 Official Date 01 Feb 2019 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance In accordance with the Rules

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is

More information

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Flow Solution FS 3700 Automated Chemistry Analyzer

Flow Solution FS 3700 Automated Chemistry Analyzer Method Abstract Total Cyanide by ASTM D7511 Document #43671116 Flow Solution FS 3700 Automated Chemistry Analyzer Total Cyanide by In-Line Ultraviolet Digestion and Amperometric Detection ASTM D7511, Segmented

More information

suppressors Eluent Suppressors for Ion Chromatography

suppressors Eluent Suppressors for Ion Chromatography suppressors Eluent Suppressors for Ion Chromatography The Suppressor Advantage Dionex introduced suppression in 97, thereby bringing ion chromatography (IC) to the forefront of modern analytical techniques

More information

Theory of Ion Chromatography

Theory of Ion Chromatography Theory of Ion Chromatography The ideal method for analyzing anions, cations and polar substances is ion chromatography. It can be used to reliably quantify substances throughout a wide concentration range.

More information

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column chromatography Obtain excellent peak shapes for hydrophobic amines without the use of solvent using the Dionex IonPac CS CationExchange Column. Product Specifications Thermo Scientific Dionex IonPac CS

More information

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,

More information

9.4 Naming and Writing Formulas for Acids and Bases. What s the name of the acid responsible for the crisp taste in this drink?

9.4 Naming and Writing Formulas for Acids and Bases. What s the name of the acid responsible for the crisp taste in this drink? CHEMISTRY & YOU What s the name of the acid responsible for the crisp taste in this drink? There s a certain acid that gives many soft drinks their crisp, enjoyable taste. 1 How do you determine the name

More information

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection Matthew Neely Pittcon Conference & Expo 2014 March 2-6, 2014 1 The world leader in serving science Outline

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25 High Performance Liquid Chromatography (HPLC) Harris Chapter 25 12/1/2005 Chem 253 - Chapter 25 1 HPLC Separation of nonvolatile or thermally unstable compounds. If the analyte/sample can be found to be

More information

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic

More information

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Chapter 4. Aqueous Reactions and Solution Stoichiometry

Chapter 4. Aqueous Reactions and Solution Stoichiometry Sample Exercise 4.1 (p. 127) The diagram below represents an aqueous solution of one of the following compounds: MgCl 2, KCl, or K 2 SO 4. Which solution does it best represent? Practice Exercise 1 (4.1)

More information

TCI Dual ~Mixed-Mode Mode column~

TCI Dual ~Mixed-Mode Mode column~ TCI Dual ~Mixed-Mode Mode column~ TCI Chromatography Department Mixed-Mode Column Target compound is basic Choose DS + Cation-Exchange Type Target compound is acidic Choose DS + Anion-Exchange Type o ion-pair

More information

Prominence for Ion Analysis

Prominence for Ion Analysis C9-E0 Prominence for Shimadzu High-Performance Liquid for HPLC Quality In 98*, Shimadzu developed its first ion chromatograph. Since that time, interest in ion chromatography has risen in accordance with

More information

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009) January 2009 FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009) This monograph was adopted at the Forty-third WHO Expert Committee on Specifications

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Chemistry 20 In Class Assignment

Chemistry 20 In Class Assignment What is Dissociation? Chemistry 20 In Class Assignment How do you complete a dissociation equation? 1. Write the ionic formula for the desired compound 2. Write an arrow with water above it (representing

More information

Experiment 6. Investigating Chemical Reactions

Experiment 6. Investigating Chemical Reactions In this experiment you will: Experiment 6. Investigating Chemical Reactions Perform and observe the results of a variety of chemical reactions. Become familiar with the observable signs of chemical reactions.

More information

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM IC Application Work AW CH6-1048-012011 Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM Branch: Chemical industry; Water, wastewater, environmental protection,

More information

Overcoming Challenging Matrices in Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography Overcoming Challenging Matrices in Ion Chromatography Presented by: Kirk Chassaniol Gulf Coast Conference 2014 October 14, 2014 Thermo Fisher Scientific NA IC Tech Support 1 The world leader in serving

More information

Properties of Compounds

Properties of Compounds Chapter 6. Properties of Compounds Comparing properties of elements and compounds Compounds are formed when elements combine together in fixed proportions. The compound formed will often have properties

More information

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,

More information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N )

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N 042195) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N 042191) QUICKSTART STEPS

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

Chapter 9. Chemical Names and Formulas

Chapter 9. Chemical Names and Formulas Chapter 9 Chemical Names and Formulas 9.1 - Naming Ions Monatomic ions: Single atom with a positive or negative charge resulting from the loss or gain of one or more valence electrons. - Cations: Groups

More information

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for

More information

Expanded capabilities in ammonium and amine detection

Expanded capabilities in ammonium and amine detection PRODUCT SPECIFICATIONS Thermo Scientifi c Dionex SC-CERS 500 Salt Converter-Cation Electrolytically Regenerated Suppressor Expanded capabilities in ammonium and amine detection Benefits Broadened ammonium

More information

2011_ST20_Taylor.pdf. SSPT Document not peer-reviewed by CORESTA

2011_ST20_Taylor.pdf. SSPT Document not peer-reviewed by CORESTA An Ion Chromatographic Method for the Quantitative Determination of Hydrogen Cyanide in Cigarette Smoke using Pulsed Amperometric Detection Dr W Guthery and Dr M J Taylor Filtrona Technology Centre CORESTA

More information

Chapter 6 Chemical Names and Formulas

Chapter 6 Chemical Names and Formulas Chemistry/ PEP Name: Date: Chapter 6 Chemical Names and Formulas Chapter 6: 1 9, 12, 14 24, 26 28, 31 36, 40, 42, 49, 52, 53, 56, 58, 62, 67 (37 total) 1. Provide the name and symbol of the ion formed

More information

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo

More information

Optimizing GPC Separations

Optimizing GPC Separations Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

DETERMINING THE FORMULA OF AN IONIC COMPOUND FROM THE NAME

DETERMINING THE FORMULA OF AN IONIC COMPOUND FROM THE NAME DETERMINING THE FORMULA OF AN IONIC COMPOUND FROM THE NAME - The name of an ionic compound is made of the names of the CATION and ANION in the compound. - To get the FORMULA, you must figure out the SMALLEST

More information

Science 1.5 AS Demonstrate understanding of aspects of acids and bases WORKBOOK. Working to Excellence

Science 1.5 AS Demonstrate understanding of aspects of acids and bases WORKBOOK. Working to Excellence Science 1.5 AS 90944 Demonstrate understanding of aspects of acids and bases WORKBOOK Working to Excellence CONTENTS 1. Writing Excellence answers to Ion Formation questions 2. Writing Excellence answers

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

suppressors SRS -ULTRA Self-Regenerating Suppressor

suppressors SRS -ULTRA Self-Regenerating Suppressor suppressors SRS -ULTRA Self-Regenerating Suppressor The Self- Regenerating Suppressor utilizes AutoSuppression technology to enhance analyte conductivity while suppressing eluent conductivity. This results

More information

c formula units of potassium iodide a moles of beryllium b moles of calcium c mole of sulfur a. 6.

c formula units of potassium iodide a moles of beryllium b moles of calcium c mole of sulfur a. 6. Chapter 11 1. Identify and calculate the number of representative particles in each of the following quantities. a. 2.15 moles of gold 2.15 mol Au 1.29 10 24 atoms Au b. 0.151 mole of nitrogen oxide 0.15O

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Data Pack. Ion Chromatography Methods. June 2009

Data Pack. Ion Chromatography Methods. June 2009 Data Pack Ion Chromatography Methods June 2009 Table of Contents Introduction. 2 Ion Chromatography Methods List. 3 Inorganic Anions in Waters..7 Inorganic Anions in High Purity Waters..15 Inorganic Disinfection

More information

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance Niacin Extended-Release Tablets Type of Posting Posting Date Official Date Expert Committee Reason for Revision Revision Bulletin 27 Jan 2017 01 Feb 2017 Non-Botanical Dietary Supplements Compliance In

More information

ph Calibration Buffers

ph Calibration Buffers ph Calibration Buffers Uncompromising Quality 3 Manufacturing/ Inventory Locations Tightest Tolerances in the Industry, Lowest Lot-to-Lot Variability Ricca has been the leading name in high quality Buffers

More information

Polymer-based Hydrophilic Interaction Chromatography (HILIC) Columns (HILICpak)

Polymer-based Hydrophilic Interaction Chromatography (HILIC) Columns (HILICpak) Polymer-based ydrophilic Interaction Chromatography (ILIC) Columns (ILICpak) Features VG-0 VT-0 VC-0 V-0 Suitable for saccharides analysis using ILIC mode Recovers reducing saccharides with high ratio