1 HPLC COLUMNS & Bulk Resins THE MEASURE OF EXCELLENCE TM

2 The Measure of Excellence Hamilton For nearly 0 years, Hamilton Company has been satisfying customer needs in the field of precision fluid measuring. It all started with syringes. Not commercial, mass produced medical syringes, but precision measuring instruments. About years ago Hamilton was the first company to develop and manufacture pressure stable polymeric HPLC columns. Columns We now offer 9 different polymer-based HPLC columns for reversed phase, anion exchange, cation exchange and ion exclusion separations. Two silica-based C8 and C8 columns are available for reversed phase separations. Choosing the Right HPLC Column Before you select an HPLC column to separate your sample please check the Hamilton Company HPLC web site at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated on Hamilton HPLC columns.

3 This brochure only contains a few of the applications which have been performed on Hamilton HPLC columns. In the brochure, columns are grouped by separation mechanism: reversed phase, anion exchange, cation exchange and ion exclusion. The Recommended Uses Table below lists a few of the possible uses for each of the column packings. Recommended Uses Reversed Phase PRP -h Long life column for LC/MS applications,synthesized DNA, and small molecule PRP-h PRP- PRP- PRP-Infinity HxSil C8, C8 Reduced system pressure for protein and peptide separations and enhanced oligonucleotide recovery General purpose ph stable long life column, synthesized DNA Gradient protein and peptide separations Nonporous support for very fast gradient separation of large proteins General purpose silica-based reversed phase Anion Exchange PRP-X00 Anions, inorganic and organic using conductivity or UV detection. 0 to 00% solvent compatible. PRP-X0 PRP-X00 PRP-X600 RCX-0 RCX-0 Similar to PRP-X00 but for lower level anions (0 ppb to 0 ppm) Gradient separation of large proteins and labeled DNA Gradient separation of labeled and unlabeled DNA Isocratic or gradient separation of carbohydrate oligomers up to DP8 Gradient separation of complex carbohydrates Cation Exchange PRP-X00 Inorganic and organic cations using conductivity or UV detection. Separate mono or divalent cations depending on mobile phase conditions. PRP-X00 PRP-X800 HC-0 HC-7 HC-7 HC-7 Glyphosate and metabolite in drinking water. Also unique hydrophilic interaction separations Mono and divalent cations in the same run. Transition metals Sugar oligomers up to DP8. Max pressure,000 psi Mono and disaccharides in corn syrup. Max pressure,000 psi Calcium Form Organic acids and sugars. Max pressure,000 psi Hydrogen Form Sugar alcohols. Max pressure,000 psi Lead Form Ion Exclusion PRP-X00 Organic acids and alcohols

4 USP L Numbers & Bulk Resins USP "L" Number and Hamilton USP "L" Number HAMILTON Column L L7 L7 L9 L L L Octadecylsilane chemically bonded to porous silica or ceramic micro-particles, to 0 µm in diameter. Octylsilane chemically bonded to porous silica particles, to 0 µm in diameter. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to µm in diameter. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, about 9 µm in diameter. A rigid, spherical styrene-divinylbenzene copolymer, to 0 µm in diameter. An anion-exchange resin made of porous polymethacrylate or polyacrylate gel with quaternary ammonium groups, about 0 µm in size. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the lead form, about 9 µm in diameter. HxSil C8 HxSil C8 HC-7 Hydrogen Form HC-7 Calcium Form PRP- PRP- PRP-X00 HC-7 Lead Form Bulk Resins Reversed Phase Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-h PSDVB* N/A 00 Å 7979 PRP-h PSDVB* N/A 00 Å 7980 PRP- PSDVB* N/A 00 Å PRP- PSDVB* N/A 00 Å HxSil C8 Silica HxSil C8 Silica Anion Exchange Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-X00 PSDVB* with Trimethyl- 0.9 meq/gm 00 Å ammoniun Exchanger PRP-X00 Poly(methacryl-.6 meq/gm Superfi amidopropryl Trimethyl- cially ammonium chloride porous PRP-X600 Poly(dimethyl-.6 meq/gm Superfi amidopropyl-methacryl- cially amide) porous Cation Exchange Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-X00 PSDVB* with Sulfonate µeq/gm 00 Å Exchanger PRP-X00 PSDVB* with Sulfonate. meq/gm N/A Exchanger * PSDVB is Poly(styrene-divinylbenzene) Bulk resin is sold by the gram.

5 PRP - Reversed Phase Reversed Phase PRP -h Polymeric 00 Å columns for reversed phase, LC/MS applications. ph stable from to. Low bleed (ideal for mass spectrometry). Robust (virtually any HPLC solvent can be used). One particle size: µm. Four column diameters:.,.6, 0 and 00 mm. Analytical and semiprep/preparative guard columns. Benzoic Acid and its Derivatives PRP-h, µ, 00 Å,. x 0 mm.,-dihdroxybenzoic Acid. -Hydroxybenzoic Acid. -Acetoxybenzoic Acid (Aspirin). Benzoic Acid. - Hydroxybenzoic Acid (Salicylic Acid) Naproxen Sodium PRP-h, µm, 00 Å,. x 0 mm,. Naproxen (0 µg/ml). Ibuprofen (80 µg/ml) I.D. 0 mm 00 mm 0 mm 0 mm. mm mm mm mm Mobil Phase: A: 0 mmol/l sodiumdihydrogenphosphate ph =. B: Acetonitrile. Gradient: 8% B (Isocratic) Flow Rate:0.60 ml/min. Column Temperature: 0 o C Detection: nm. Injection Volumn: µl Analytical Guard Columns Starter Kit 797 ( holder, cartridges) Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm Semiprep/Preparative Guard Column Starter Kit 797 ( holder, cartridge) Replacement Cartridges (/pk) 7976 *** Semiprep/preparative guard column for steel columns is.6 x 0 mm 0 Mobil Phase: A: 0 mmol/l Sodiumdihydrogenphosphate ph = B: Acetonitrile. Gradient: Isocratic 0% A/0%B Flow Rate:0.60 ml/min. Column Tempera ture: 60 o C Detection: nm. For Steel Columns* For Steel Columns***

6 PRP-h Reversed Phase Polymeric 00 Å columns for oligonucleotide purification and protien separations. ph stable from to. Robust (virtually any HPLC solvent can be used). Hydrophilic polymer structure delivers faster oligonucleotide purification. -mer Oligonucleotide Purification PRP-h, PRP-h,. x µ, 0 00 mm, Å,. µm x 0 00 mm Å One particle size: µm. Three column diameters:.,.6 and 0 mm. Analytical and semiprep/preparative guard columns Mobile phase: A: 0. mol/teaa,ph = 7 B: 0. mol/l TEAA, ph = 7, % Acetonitrile Gradient: 0-80 %B in min. Flow Rate: 0.60 ml/min Column Temp: 60 o C Detection: 60 nm I.D. 0 mm 00 mm 0 mm 0 mm. mm mm mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Analytical Guard Columns Starter Kit 7967 ( holder, cartridges) Replacement Cartridges (/pk) 7968 * Analytical guard column for steel columns is. x 0 mm Semiprep/Preparative Guard Column Starter Kits 7977 ( holder, cartridge) Replacement Cartridges (/pk) 7978 *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns* For Steel Columns***

7 PRP- Reversed Phase Polymeric 00 Å columns for general reversed phase separations. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (stable to any concentration of water or organic solvent). Five particle sizes:, 7, 0, -0 and 0-0 µm. Eleven column internal diameters:.0 to 0.6 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Small Molecules DNA with Secondary Structure Biocides found in Soap PRP-,. x 0 mm, µm (P/N 7980) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Cytosine. Uracil. Uridine. Failure Sequences. -DMT 6mer. Chloroxylenol 00 ppm. Triclocarban 00 ppm Seconds Conditions: 0.0M Citric Acid ph.. Isocratic. Ambient. ml/min. 0 µl, UV nm Conditions: A) 0mM Sodium Hydroxide ph.7; B) : 0mM Sodium Hydroxide : Acetonitrile. Linear Gradient 0% B (0- min), 0-0% B (- min). 60 C. ml/min. UV 60nm Conditions: : Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 6

8 PRP- Reversed Phase Surfactant Surfactant Fatty Acids PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 00 mm, µm (P/N 7980). Sodium Octadecylsulfate 00 ppm. Sodium Dodecylsulfate 00 ppm. Caproic Acid. Caprylic Acid. Capric Acid. Lauric Acid. Palmitic Acid 6. Stearic Acid 6 0 Conditions:.:. Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity Conditions: :7 Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity 0 0 Conditions: A) : Acetonitrile : Water; B) Acetonitrile. Linear Gradient 0-00% B in min. Hold for min. Ambient. 0. ml/min. 0 µl, UV nm. Isomeric C8 Fatty Acids Chlorhexidine Gluconate Resveratrol PRP-,. x 0 mm, 7 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Linolenic Acid (C8:). Linoleic Acid (C8:). Oleic Acid (C8:). Stearic Acid (C8:0). Chlorhexidine Gluconate µg. Resveratrol Conditions: 0.% Trifluoroacetic Acid in 9: Acetonitrile : Water. Isocratic. Ambient. 0.8 ml/min. 00 µl, UV 0 nm. 0 6 Conditions: :0:69 Trifluoroacetic Acid : Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. µl, UV nm Conditions: :7 Acetonitrile : 0.M Sodium Dihydrogen Phosphate ph.. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. Pyridinoline Diphenylguanidine Folic Acid PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Pyridinoline, mg/ml. Diphenylguanidine mg/ml. Folic Acid 0 Conditions: :9 Acetonitrile : Deionized Water with 0.% Heptafluorobutyric Acid. Isocratic. Ambient. ml/min. µl, UV 80 nm. 0 Conditions: :8 Acetonitrile : Deionized Water with 0. % Trifluoroacetic Acid. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. 0 0 Conditions: 97.:. 0mM Sodium Phosphate ph 6. : Acetonitrile. Isocratic Ambient. ml/min. µl, UV 80 nm. 7

9 PRP- Reversed Phase Pregnenolone and Pregnenolone--sulfate Water Soluble Vitamins Fat Soluble Vitamins PRP-,. x 0 mm, 7 µm (P/N 79). Pregnenolone--sulfate. Pregnenolone PRP-,. x 0 mm, 0 µm (P/N 79). Niacinamide. Pyridoxine (B6). Thiamine (B). Riboflavin (B). Cyanocobalamine (B) PRP-,. x 0 mm, 7 µm, (P/N 79). Retinol (Vitamin A) 00 ppm. Calciferol (Vitamin D) 0 ppm. alpha-tocopherol (Vitamin E) 0 ppm. Phylloquinone (Vitamin K) 0 ppm 0 0 Conditions: 7: Acetonitrile : mm Tetrabutylammonium Hydrogensulfate. Isocratic. Ambient. ml/min. 0 µl, UV 0 nm Conditions: A) 0.N Perchloric Acid; B) Acetonitrile. Linear Gradient -0%B in 0 min. Ambient. ml/min. 0 µl, UV 0 nm Conditions: 0:70:0 Tetrahydrofuran : Acetonitrile : Water. Isocratic. Ambient.. ml/min. 00 µl, UV 80 nm. I.D. x Length µm 7 µm 0 µm -0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm* x 0 mm x mm 79789**. x 0 mm 79. x 00 mm x 0 mm x 0 mm x 0 mm* x 00 mm* x 0 mm* * PEEK hardware ** Cartridge Column, Cartridge Holder P/N 908 must be purchased separately. I.D. x Length µm 7 µm 0 µm -0 µm 0-0 µm.6 x 0 mm* x 00 mm x 00 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm x 00 mm x 0 mm x 0 mm x 0 mm 79 Analytical Guard Columns For Steel Columns* For PEEK Columns** Semiprep/Preparative Guard Column For Steel Columns*** Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 79 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. 8

10 PRP- Reversed Phase Polymeric 00 Å columns for protein separations. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (the support can be cleaned with strong acid or base to remove any sample residue). Two particle sizes: 0 and -0 µm. Eight column internal diameters:.0 to 0.8 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Proteins PRP-,. x 0 mm, 0 µm (P/N 7966). Ribonuclease A. Cytochrome c. Lysozyme. Myoglobin. Ovalbumin 0 8 Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient -0% B in min. Hold min. Ambient. ml/min. 00 µl, UV nm. Proteins at ph. PRP-,. x 0 mm, 0 µm (P/N 7966) Ribonuclease A.0 mg/ml. Insulin.0 mg/ml. Cytochrome c.0 mg/ml. Trypsin.0 mg/ml. Lysozyme.0 mg/ml 6. Pyruvate Dehydrogenase 0. mg/ml Conditions: A) 0.% TFA in 0mM Sodium Hydroxide ph.; B) 0.% TFA in Acetonitrile. Linear Gradient 0-60% B in 0 min. Ambient. ml/min. 0 µl, UV 0 nm. I.D. x Length 0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm. x 00 mm x 0 mm 799. x 0 mm x 00 mm I.D. x Length 0 µm -0 µm. x 0 mm x 0 mm x 0 mm* x 0mm* x 0 mm* x 0 mm x 0 mm 796. x 0 mm x 0 mm 7987 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Semiprep/Preparative Guard Column For Steel Columns* Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 79 9 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm

11 PRP-Infinity Reversed Phase Polymeric nonporous packing for fast gradient separation of large proteins. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (the support can be cleaned with strong acid or base to remove any sample residue). One particle size: µm. Three column internal diameters:. to 0.0 mm. One column material: 6 stainless steel. Proteins PRP-Infinity,. x mm, µm (P/N 7970). Ribonuclease A. Cytochrome c. Transferrin. Bovine Serum Albumin. Concanavalin A 6. Ovalbumin 6 Proteins PRP-Infinity,. x mm, µm (P/N 7970) 6. Ribonuclease A. Cytochrome c. Transferrin. Bovine Serum Albumin. Concanavalin A 6. Ovalbumin I.D. x Length µm. x mm x 00 mm x mm x 0 mm x 60 mm 797 For PRP-Infinity columns an in-line filter is recommended as a guard column is not available. 0 0 Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient 0-60% B in 0 min. Ambient. ml/min. 0 µl, UV nm Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient -60% B at 0.6% per second. Ambient. ml/min. 0 µl, UV nm. Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. 0

12 HxSil C8 & C8 Reversed Phase Silica-based 00 Å columns for general reversed phase separations. Separation of closely related PAHs. Better retention of poorly retained compounds. Separation of neutral, acidic and basic compounds without tailing (tailing factor of less than.0). Two particle sizes: and µm. Five column internal diameters:. to. mm. Analytical and semiprep/preparative guard columns in 6 stainless steel. Sunscreens in Lip Balm Sunscreen Compounds Diphenhydramine in Itch Relief Gel HxSil C8,.6 x 0 mm, µm (P/N 79868). Oxybenzone. Octocrylene. Octyl Methoxycinnamate. Avobenzone (Parsol 789). Octyl Salicylate HxSil C8,.6 x 0 mm, µm (P/N 79868). -Hydroxy-- methoxybenzophenone. -Ethylhexyl trans-- methoxycinnamate. -Ethylhexylsalicylate HxSil C8,.6 x 0 mm, µm (P/N 79868). Diphenhydramine 0 ppm Conditions: 8: Methanol : Water. Isocratic. Ambient. ml/min. ul, UV 08 nm. 0 0 Conditions: 7: Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 0 Conditions: 9: Methanol : 0mM Potassium Hydrogen Phosphate ph 7.0. Isocratic. Ambient. ml/min. µl, UV nm. Meclizine in Tablets Tetracycline by USP Method Oxytetracycline and Tetracycline HxSil C8,.6 x 0 mm, µm (P/N 79868) HxSil C8,.6 x 0 mm, µm (P/N 79869) HxSil C8,.6 x 0 mm, µm (P/N 790). Meclizine mg/ml. Tetracycline 0. mg/ml. Oxytetracycline 0. mg/ml. Tetracycline 0. mg/ml 0 0 Conditions: 9: Methanol : 0mM Potassium Hydrogen Phosphate ph 7.0. Isocratic. Ambient. ml/min. µl, UV nm Conditions: 680 ml 0.N Ammonium Oxalate, 70 ml Dimethylformamide, 0 ml 0.M Dibasic Ammonium Phosphate ph 7.6. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. 0 0 Conditions: 680 ml 0.N Ammonium Oxalate, 70 ml Dimethylformamide, 0 ml 0.M Dibasic Ammonium Phosphate ph 7.6. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm.

13 HxSil C8 & C8 Reversed Phase Folic Acid, Methotrexate by USP Method Antibiotics Small Molecules HxSil C8,.6 x 0 mm, µm (P/N 79868) 0 0 Conditions: 9: 0.6M Sodium Phosphate, Dibasic, 0.07M Citric Acid ph 6.0 : Acetonitrile. Isocratic. Ambient.. ml/min. 0 µl, UV 0 nm.. Folic Acid 00 µg/ml. Methotrexate 00 µg/ml HxSil C8,.6 x 0 mm, µm (P/N 790). Ampicillin. Oxacillin. Dicloxacillin 0 0 Conditions: : 0.0M Potassium Phosphate ph 7 : Acetonitrile. Isocratic. Ambient. ml/min. µl, UV nm. HxSil C8,.6 x 0 mm, µm (P/N 79868) 6. Uracil. Caffeine. Phenol. Toluene. Butylbenzene 6. Triphenylene 7. Amylbenzene 8. Terphenyl Conditions: 7: Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 7 8 HxSil C8 I.D. x Length µm µm. x mm 796. x 0 mm x 7 mm x 00 mm x 0 mm x 0 mm 79.6 x mm 79 I.D. x Length µm µm.6 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm 790. x 0 mm 7906 Analytical Guard Column For Steel Columns* Semiprep/Preparative Guard Column For Steel Columns* Starter Kit 798 Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) 79 Replacement Cartridges (/pk) 796 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm HxSil C8 I.D. x Length µm µm. x mm x 0 mm x 7 mm x 00 mm x 0 mm x 0 mm x mm I.D. x Length µm µm.6 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm x 0 mm 7987 Analytical Guard Column For Steel Columns* Semiprep/Preparative Guard Column For Steel Columns* Starter Kit 799 Starter Kit 797 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) 79 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.

14 Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride from the water dip. Use with organic solvent from 0 to 00 % for elution of hydrophobic anions or column cleaning. ph stable from to. Use conductivity or UV detection. Three particle sizes:, 0 and -0 µm. Eight column internal diameters:.0 to 0.8 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Common Anions Anions by Indirect UV Detection EDTA PRP-X00,. x 0 mm, µm (P/N 7980). Fluoride. Chloride. Nitrite. Bromide. Nitrate PRP-X00,. x 0 mm, 0 µm (P/N 79). Fluoride 0 ppm. Carbonate 0 ppm. Chloride 0 ppm. Nitrite 0 ppm. Bromide 0 ppm 6. Nitrate 0 ppm 7. Phosphate 0 ppm 8. Sulfate 0 ppm PRP-X00,.6 x 0 mm, 0 µm (P/N 79). Copper EDTA 0 ppm Conditions: mm p-hydroxybenzoic Acid ph 8. w/.% Methanol ml/min. 00 µl, Conductivity Conditions: mm p-hydroxybenzoic Acid ph 8.9 with. % Methanol. Isocratic. Ambient. ml/min. 00 µl, Indirect UV 0 nm. 0 6 Conditions: mm Sulfuric Acid. Isocratic. Ambient. ml/min. 00 ul, UV nm.

15 PRP-X00 Anion Exchange Organic Acids Germall Bromate and Other Anions PRP-X00,. x 0 mm, 0 µm (P/N 79). Formic Acid 0 µg. Fluoroacetic Acid 0 µg. Isopropylmethyl Phosphonic Acid 0 µg. Chloroacetic Acid 0 µg PRP-X00,.6 x 0 mm, 0 µm (P/N 79),. Germall mg/ml PRP-X00,. x 0 mm, 0 µn (P/N 79). Fluoride 0 ppm. Chloride 0 ppm. Bromate 0 ppm. Bromide 0 ppm. Nitrate 0 ppm 0 0 Conditions: 0.M Sodium Hydroxide in :9 Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity. 0 0 Conditions: 7: 0mM Sodium Hydroxide : Methanol. Isocratic. Ambient. ml/min. 0 µl, UV 0 nm Conditions:.7mM Sodium Bicarbonate,.8mM Sodium Carbonate, 0.mM Sodium Thiocyanate. Isocratic. Ambient. ml/min. 0 µl, Suppressed Conductivity. Sulfite and Sulfate Phosphate and Phosphite Chlorite and Chlorate PRP-X00,.6 x 0 mm, 0 µm (P/N 79). Sulfite.7 mg/ml. Sulfate 0. mg/ml PRP-X00,. x 0 mm, 0 µm (P/N 79). Fluoride 0 ppm. Phosphate 0 ppm. Phosphite 0 ppm. Chloride 0 ppm PRP-X00,. x 0 mm, 0 µm (P/N 79) Fluoride. Chlorite. Chloride. Nitrite. Phosphate 6. Bromide 7. Nitrate 8. Chlorate 0 6 Conditions: 80:0 8mM p-hydroxybenzoic Acid ph 0.0 : Methanol. Isocratic. Ambient. ml/min. 0 µl, Conductivity Conditions: 0mM Succinic Acid ph.9. Isocratic. Ambient. ml/min. 00 µl Conductivity Conditions:.0mM -Amino--Hydroxybenzoic Acid ph.8. Isocratic. Ambient. ml/min.00 µl, Indirect UV 0 nm. I.D. x Length µm 0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm 79. x 0 mm* x 0 mm x 0 mm 796. x 00 mm x 0 mm 79 I.D. x Length µm 0 µm -0 µm. x 0 mm x 0 mm* x 0 mm* x 0 mm x 0 mm x 0 mm 79. x 00 mm 79. x 0 mm 79. x 0 mm x 0 mm 79 PEEK hardware Analytical Guard Columns For Steel Columns** For PEEK Columns*** Semiprep/Preparative Guard Column For Steel Columns**** Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 796 ** Analytical guard column for steel columns is. x 0 mm *** Analytical guard column for PEEK columns is.0 x 8.0 mm **** Semiprep/preparative guard column for steel columns is.6 x 0 mm

16 PRP-X0 Anion Exchange Polymeric anion exchange packings for separation of inorganic and organic anions from 0 ppb to 0 ppm. Good separation of fluoride from the water dip. Compatible with conductivity or UV detectors. Use with organic solvent up to 00% ph stable from to. Anions One particle size: 7 µm. Four column internal diameters:.0 to.6 mm. Polarizable Anions Two column materials: 6 stainless steel and PEEK. Analytical guard columns. Glucaric Acid PRP-X0,. x 0 mm, 7 µm (P/N 797) 6 7. Fluoride ppm. Chloride ppm. Nitrite ppm. Bromide ppm. Nitrate ppm 6. Phosphate ppm 7. Sulfate ppm PRP-X0S,. x 0 mm, 7 µm (P/N 797) 6. Fluoride ppm. Chloride ppm. Iodide 0 ppm. Sulfate 0 ppm. Thiosulfate 0 ppm 6. Perchlorate 0 ppm PRP-X0,. x 0 mm, 7 µm (P/N 797). Glucaric Acid 000 ppm 0 8 Conditions:.0mM p-hydroxybenzoic Acid ph 9.. Isocratic. Ambient. ml/min. 00 µl, Non-Suppressed Conductivity. 0 7 Conditions: mm Sodium Hydroxide with mm Phenol, 0.0mM Sodium Thiocyanate. Ambient.. ml/min. 0 µl, Suppressed Conductivity. 0 6 Conditions: :7 Acetonitrile : 0mM Potassium Phosphate, ph 6.. Isocratic. Ambient.. ml/min. 0 µl, UV 0 nm. PRP-X0 PRP-X0S I.D. x Length 7 µm 7 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm* x 0 mm* x 0 mm* x 00 mm x 0 mm x 0 mm PRP-X0 PRP-X0S I.D. x Length 7 µm 7 µm.6 x 00 mm* x 0 mm* x 0 mm* * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm

17 PRP-X00 Anion Exchange Polymeric strong-base anion exchange packing with limited porosity for separation of proteins. Fast separation of large proteins. ph stable from to. One particle size: 7 µm. Three column internal diameters:. to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Higher sample capacity than nonporous supports. DMT-on Antisense Phosphorothioate 8mer PRP-X00,.6 x 0 mm, 7 µm (P/N 797). DMT-on Phosphorothioate 8mer Proteins PRP-X00,.6 x 0 mm, 7 µm (P/N 797). Myoglobin 7 µg. Conalbumin 7 µg. Dog Albumin 77 µg Conditions: A) 8: 00mM TRIS ph 8.0 : Acetonitrile; B) 8: 00mM TRIS ph.0,.m Lithium Chloride : Acetonitrile. Linear Gradient 0-00% B in 0 min. ml/min. 00 µl of a mg/ml solution, UV 60nm. 0. Conditions: A) 0mM Tris ph 9.0; B) 0mM Tris ph 9.0, 0.N Sodium Chloride. Linear Gradient 0-0% B in. min. Hold for. min. Ambient. ml/min. 0 µl, UV nm. I.D. x Length 7 µm. x 0 mm* x 0 mm 79.6 x 0 mm* x 0 mm* x 00 mm 798 Analytical Guard Column For PEEK Columns* Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 790 * Analytical guard column for PEEK columns is.0 x 8.0 mm * PEEK hardware 6

18 PRP-X600 Anion Exchange Polymeric weak-base anion exchange packing for gradient separation of proteins and DNA oligomers. Limited porosity allows separation of large DNA fragments. ph stable from to. One particle size: 7 µm. Column material: PEEK. Guard column in PEEK. Higher sample capacity than nonporous supports. Separation of DNA Fragments DMT-on Phosphorothioate 8mer Proteins PRP-X600,.6 x 0 mm, 7 µm (P/N 7960) PRP-X600,.6 x 0 mm, 7 µm (P/N 7960). DMT-on Phosphorothioate 8mer PRP-X600,.6 x 0 mm, 7 µm (P/N 7960). Myoglobin mg/ml. Concalbumin mg/ml. Ovalbumin mg/ml. Bovine Serum Albumin mg/ml Conditions: A) 0mM TRIS, mm EDTA ph 9.0; B) N NaCl in A, Linear Gradient % B in min. 67.%-7% B (- min.). Ambient. ml/min. µl, UV 60 nm Conditions: A) 8: 00mM TRIS ph 8.0 : Acetonitrile; B) 8: 00mM TRIS ph.0,.m Lithium Chloride : Acetonitrile. Linear Gradient 0-00% B in 0 min. ml/min. UV 60 nm. 0 7 Conditions: A) 0mM TRIS ph 9.0; B) 0mM TRIS, ph 9.0,.0M Sodium Chloride. Linear Gradient 0 to %B in 0 min. Hold min. ml/min. UV 0nm. 7 I.D. x Length 7 µm.6 x 0 mm* x 00 mm* x 0 mm* x 0 mm* 7989 * PEEK hardware Analytical Guard Column For PEEK Columns* Starter Kit ( holder, cartridges) 796 Replacement Cartridges (/pk) 796 * Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.

19 RCX-0 Anion Exchange Polymeric anion exchange packing for isocratic or gradient separation of carbohydrates. ph stable from to. Isocratic separation of mono and disaccharides. Gradient separation of oligomers up to DP8. Compatible with PAD, conductivity and RI detectors. One particle size: 7 µm. Three column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in stainless steel and PEEK. Glycols in Water Acetyl Glucosamine Artichoke Tubers RCX-0,. x 0 mm, 7 µm (P/N 790). Ethylene Glycol 00 ppb. Propylene Glycol 00 ppb 0 8 Conditions: 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 0 µl, Pulsed Amperometric, Dual Gold Electrode. E=60 mv T=66 msec E=900 mv T=66 msec E=-800 mv T=00 msec RCX-0,. x 0 mm, 7 µm (P/N 790). Galactosamine 00 ppm. Glucosamine 00 ppm. Acetyl-Glucosamine 00 ppm 0 7 Conditions: 0mN Sodium Hydroxide (purged with Helium during the run) Isocratic. Ambient. ml/min. 0 µl, Refractive Index. RCX-0,. x 0 mm, 7 µm (P/N 790). DP. DP. DP0. DP 0 0 Conditions: A) 60mM Sodium Hydroxide; B) 60mM Sodium Hydroxide with 00mM Sodium Acetate. Gradient: 0-00%B in 0 min. ml/min. 0 µl, Pulsed Amperometric, Dual Gold Electrode E=00 mv T= msec E=800 mv T=66 msec E=-600 mv T=99 msec I.D. x Length 7 µm. x 0 mm x 0 mm x 0 mm* 7988 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm 8

20 RCX-0 Anion Exchange Polymeric anion exchange packing for isocratic or gradient separation of complex carbohydrates. ph stable from to. Isocratic or gradient modes. Higher ion exchange capacity support for separation of closely related carbohydrates. Compatible with PAD and RI detectors. One particle size: 7 µm. Three column internal diameters:.,. and.6 mm. Two column materials: Stainless steel and PEEK. Guard column in PEEK. Glycoprotein Monosaccharides Corn Syrup Artichoke Tubers RCX-0,.6 x 0 mm, 7µm (P/N 7970). Fucose. Galactosamine. Glucosamine. Galactose 6. Glucose 6. Mannose RCX-0,.6 x 0 mm (P/N 7970) Glucose. Fructose. Maltose. Maltotriose. Maltotetraose 6. Maltopentaose 7. Maltohexaose 8. Maltoheptaose 9. Maltooctaose RCX-0,.6 x 0 mm (P/N 7970). Glucose. Fructose. Sucrose. DP. DP0 6. DP Conditions: 6mN Sodium Hydroxide. Isocratic. Ambient. ml/min. µl, Pulsed Amperometric µafs Dual Gold Electrode E=600 mv T=66 msec E=600 mv T=66 msec E=-800 mv T=9 msec Conditions: A) 60mM Sodium Hydroxide; B) 00mM Sodium Acetate in A. Linear Gradient 00% A for min., then 0-00% B (- min.) Ambient. ml/min. 0 µl. Pulsed Amperometric Dual Gold Electrode. E=0 mv T=66 msec E=900 mv T=66 msec E=-80 mv T=00 msec Conditions: A) 60mM Sodium Hydroxide; B) 00mM Sodium Acetate in A. Linear Gradient: 0-0% B in 0 min., then 0-00% B (0-0 min.). Ambient. ml/min. 0 µl, Pulsed Amperometric Dual Gold Electrode. E=0 mv T=66 msec E=900 mv T=66 msec E=-800 mv T=00 msec 9 I.D. x Length 7 µm Analytical Guard Column For PEEK Columns*. x 0 mm 7970 Starter Kit ( holder, cartridges) 797. x 0 mm 7980 Replacement Cartridges (/pk) x 0 mm* 7970 * Analytical guard column for PEEK columns is.0 x 8.0 mm.6 x 0 mm* * PEEK hardware Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.

21 Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent up to 00% for elution of hydrophobic cations and column cleaning. Compatible with conductivity and UV detectors. One particle size: 0 µm. Six column internal diameters:.0 to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Monovalent Cations Glycine and Ethanolamine N-Methylglucamine PRP-X00,. x 0 mm (P/N 79). Lithium. Sodium. Ammonium. Potassium. Cesium PRP-X00,. x 0 mm (P/N 79). Glycine. Sodium. Ethanolamine PRP-X00,. x 0 mm (P/N 79). N-Methylglucamine mg/ml 0 0 Conditions:.: mm Nitric Acid: Methanol. Isocratic. Ambient. ml/min. 00 µl, Conductivity. 0 6 Conditions: mn Nitric Acid. Ambient. Isocratic. ml/min. 0 µl, Conductivity. 0 8 Conditions: mn Nitric Acid. Isocratic. Ambient. ml/min. µl, Conductivity. I.D. x Length 0 µm I.D. x Length 0 µm.0 x 0 mm x 0 mm 79.0 x 00 mm x 0 mm 79.0 x 0 mm x 0 mm* 79.0 x 0 mm x 0 mm* 798. x 0 mm x 0 mm* 797. x 0 mm x 0 mm x 00 mm x 0 mm 799 * PEEK hardware * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) Semiprep/Preparative Guard Column Starter Kits ( holder, cartridge) 797 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 m *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns*** 0

22 PRP-X00 Cation Exchange Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water. Faster analysis when compared to competitor s columns. Detection levels of less than 0 ppb when using the post column, OPA derivatization technique. Applicable to other separations, such as inositol and sugar alcohols. Two particle sizes: 7 and -0 µm. Five column internal diameters:. to. mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Glyphosate and Metabolite Inositol in Vitamin Matrix Sugar Alcohols PRP-X00,. x 0 mm, 7 µm (P/N 797). Glyphosate. Aminomethylphosphonic Acid PRP-X00,. x 0 mm, 7 µm (P/N 797),,, and. Unknown. Inositol PRP-X00,. x 0 mm, 7 µm (P/N 797). Adonitol 00 ppm. Arabitol 00 ppm. Xylitol 00 ppm. Mannitol 00 ppm. Sorbitol 00 ppm 0 6 Conditions: 0.00M Monobasic Potassium Phosphate. Isocratic. Ambient. 0. ml/min. 00 µl, Excitation wavelength 8 nm. Emission wavelength nm. Post Column Conditions: Oxidation Solution Flow Rate: 0.0 ml/min; Reaction Coil: ml (0.0 cm ID X m); Reaction Time:. min; Temp: 8 C Derivatization Solution: 0.0 ml/min; Reaction Coil: 0.0 ml (0.0 cm ID X m), Ambient. Conditions: 8: Acetonitrile : 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 00 µl, Pulsed Amperometric Dual Gold Electrode. E=00 mv T=76 msec E=000 mv T=66 msec E=-800 mv T=99 msec Post Column Conditions: 0.N Sodium Hydroxide solution at ml/min Conditions: A) Acetonitrile; B) Water. Linear Gradient 0-0% B in 0 min. Ambient. ml/min. µl, Pulsed Amperometric Dual Gold Electrode; delay 0 msec E=00mV T=70msec E=000mV T=0msec E=-800mV T=00msec Post Column Conditions: 0.N Sodium Hydroxide at ml/min. I.D. x Length 7 µm -0 µm. x 0 mm x 0 mm x 0 mm x 0 mm x 0 mm* x 0 mm 797. x 0 mm 79 * PEEK hardware Analytical Guard Column Starter Kit ( holder, cartridges) 7976 Replacement Cartridges (/pk) 7977 C8 Guard Column for EPA Glyphosate Application Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 79 PRP-X00 Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 79 Replacement Cartridges (/pk) 79 * Analytical guard column for PEEK columns is.0 x 8.0 m ** Analytical guard column for steel columns is. x 0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For PEEK Columns* For Steel Columns** For Steel Columns***

23 PRP-X800 Cation Exchange Polymeric cation exchange columns for the isocratic separation of mono and divalent cations. Isocratic separation of lithium, sodium, ammonium, potassium, magnesium and calcium. Gradient separation of transition metals. Excellent durability (stable to any concentration of water or organic solvent). One particle size: 7 µm. Two column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in 6 stainless steel and PEEK. Mono and Divalent Cations Transition Metals Transition Metals PRP-X800,. x 0 mm, 7 µm (P/N 7988). Lithium ppm. Sodium ppm. Ammonium ppm. Potassium ppm. Magnesium ppm 6. Calcium ppm 0 6 Conditions: mm Cupric Sulfate. Isocratic. Ambient. 0.8 ml/min. 0 µl, Indirect UV 0 nm. 6 PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Cadmium 6 ppm. Zinc 6 ppm. Cobalt 6 ppm Conditions: A) 0mM Ammonium Acetate. ph.; B) Trifluoroacetic Acid in Water ph.. Linear Gradient -% B in 0 min. ml/min. 00 µl, Post Column Reaction: 0.0% -(-pyridylazo)resorcinol in M Ammonium Hydroxide 0. ml/min. Visible 0 nm. PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Zinc 6 ppm. Cadmium 6 ppm. Lead 6 ppm Conditions: A). mm Ethylenediamine ph.; B) 00mM Ethylenediamine ph.7. Linear Gradient 00% A (0- min.), 0-00% B in (-0 min.) ml/min, 00 µl, Post Column Reaction: 0.0% -(-pyridylazo) resorcinol (PAR) in M Ammonium Hydroxide, 0. ml/min. Visible 0 nm. I.D. x Length 7 µm. x 0 mm 798. x 0 mm x 0 mm* x 0 mm* 7989 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.

24 HC-0 Cation Exchange Polymeric % cross-linked soft-gel column for cation, ligand exchange separation of carbohydrates. Separate oligosaccharides up to DP8. Water mobile phase. Compatible with RI detectors. One particle size: 0 - µm. One column internal diameter: 7.8 mm. One column material: 6 stainless steel. Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79) 76. Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltooctaose + High Conversion Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79). Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltoheptaose Conditions: Water. Isocratic. 80 C. 0.6 ml/min. µl, Refractive Index Conditions: Deionized Water. Isocratic. 80 C. 0.6 ml/min. 0 µl, Refractive Index. Guard Columns For Steel Columns* Gel-Type Cation Exchange Column I.D. x Length 0- µm 7.8 x 0 mm 79 Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-0 guard column for steel columns is.6 x 0 mm

25 HC-7 Cation Exchange Polymeric 7.% cross-linked soft-gel columns for cation, ligand exchange separations of carbohydrates. Compatible with UV and RI detectors. Hydrogen form columns for USP L7 applications. Calcium form columns for USP L9 applications. Lead form columns for USP L applications. One particle size: 9 µm. Three column internal diameters:., 7.8 and 0.0 mm. One column material: 6 stainless steel. Three forms: calcium, lead and hydrogen. Malic Acid Citric, Lactic and Acetic Acids Dihydroxyacetone HC-7,. x 0 mm H + (P/N 7976). Maleic Acid ppm. Malic Acid 000 ppm. Fumaric Acid 0 ppm HC-7,. x 0 mm H + (P/N 7976). Citric, Acid 0 ppm. Lactic Acid 0 ppm. Acetic Acid 0 ppm HC-7, 7.8 x 0 mm Ca + (P/N 796). Formic Acid 0. mg/ml. Glycerol 0. mg/ml. Dihydroxyacetone 0. mg/ml 0 0 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 6 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 0 Conditions: 0.0M Calcium Chloride. Isocratic. 90 C. 0.6 ml/min. ul, Refractive Index. Gel-Type Cation Exchange Columns 9 µm, 9 µm, 9 µm, I.D. x Length Calcium Lead Hydrogen. x 0 mm x 00 mm x 0 mm x 0 mm 798 Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Guard Columns Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-7 guard column for steel columns is.6 x 0 mm For Steel Columns*

26 Ion Exclusion PRP-X00 Polymeric ion exclusion packing for separation of alcohols and organic acids. Separate structurally similar alcohols. Separate similar organic acids. Use with organic solvent from 0 to 00% for elution of highly retained compounds. One particle size: 7 µm. Two column materials: 6 stainless steel and PEEK. Five column internal diameters:.0 to 0.0 mm. Analytical and semiprep/preparative guard columns. Fatty Acids Acrylamide and Acrylic Acid Organic Acids PRP-X00,. x 0 mm (P/N 796). Acetic Acid 00 ppm. Propionic Acid 00 ppm. Isobutyric Acid 00 ppm. Butyric Acid 00 ppm. Isovaleric Acid 00 ppm 6. Valeric Acid 00 ppm 6 PRP-X00,. x 0 mm (P/N 796). Acrylamide ppm. Acrylic Acid 0 ppm. Acrylonitrile 67 ppm PRP-X00,. x 0 mm (P/N 796). Tartaric Acid. Malic Acid. Citric Acid. Lactic Acid. Acetic Acid Conditions: 0:80 t-butyl Alcohol : 0mM Potassium Phosphate Monobasic ph.. Isocratic. Ambient. ml/min. 00 µl, UV nm. 0 6 Conditions: 9: mn Sulfuric Acid : Acetonitrile. Isocratic. Ambient. ml/min. µl, UV 0 nm. 0 6 Conditions: mn Sulfuric Acid. Isocratic. Ambient. ml/min. 0 ul, UV 0 nm. I.D. x Length 7 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm x mm 796. x 0 mm 796. x 0 mm 796. x 0 mm x 0 mm* x 0 mm* x 0 mm 797 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 799 Replacement Cartridges (/pk) 790 * Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com For Steel Columns*

Anion Exchange HPLC Columns

Anion Exchange HPLC Columns Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

HPLC. Columns and Resins. For a Complete Range of Applications

HPLC. Columns and Resins. For a Complete Range of Applications HPLC Columns and Resins For a Complete Range of Applications 0 HPLC COLUMNS AND RESINS HAMILTON Polymeric and Silica-Based Packings for a Complete Range of HPLC Separations To order products from this

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

IC Columns Introduction

IC Columns Introduction IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

HPLC Columns and Accessories. Solutions for liquid chromatography

HPLC Columns and Accessories. Solutions for liquid chromatography HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance

More information

HPLC Columns and Accessories. Solutions for liquid chromatography

HPLC Columns and Accessories. Solutions for liquid chromatography HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS17-C Anion Exchange Column columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column

More information

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Pittcon 2005 BINGWEN YAN 1, CLAYTON V. MCNEFF 1, 1 ZirChrom Separations, Inc., 617 Pierce Street,

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is

More information

Saccharides and Organic Acids

Saccharides and Organic Acids Saccharides and Organic Acids Contents Introduction... 2 Reducing Sugars... 2 HILIC The HILICpak and Ashipak Series... 3 Shodex HILIC Columns for Sugar Analysis... 7 Ligand Exchange Shodex SUGAR series...

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

IC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories

IC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories IC Section IC Columns..............................304-316 Introduction..............................305-306 Allsep Anion Columns...................... 307 Novosep Anion Columns.................... 308

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm

More information

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for

More information

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WAX-1 Columns User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase AQUASIL C8 Columns AQUASIL 8 Columns TG0-0 Compatible with 00% aqueous mobile phase AQUASIL OH OH AQUASIL C8 columns provide a versatile C8 phase for a wide range of application areas. AQUASIL C8 columns

More information

Acclaim HILIC-10 Columns

Acclaim HILIC-10 Columns Thermo Scientific Acclaim HILIC- Columns Product Manual P/N: January 3 Part of Thermo Fisher Scientific Product Manual for Acclaim HILIC- Analytical Column Acclaim HILIC-, 3 µm, Analytical, 4.6 x 5 mm

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

ProPac WCX-10 Columns

ProPac WCX-10 Columns ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Catalogue 9 Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Media Compatibility Guide PVC Valves

Media Compatibility Guide PVC Valves 73 F (23 C) Valves WARNING This chart indicates the suitability of various elastomers and plastics for use with fluids to be conveyed. It should be used only as a guide for the selection of valve materials.

More information

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

IC5000 Ion Chromatography System

IC5000 Ion Chromatography System IC000 Ion Chromatography System Quaternary gradient pumping and on-line eluent preparation to improve separations in complex samples In-line sample filtration to 0.8 µm to eliminate manual filtrations

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

500 SERIES CHEMICAL RESISTANCE GUIDE

500 SERIES CHEMICAL RESISTANCE GUIDE 500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior

More information

Magnetic Flowmeter Material Selection Guide

Magnetic Flowmeter Material Selection Guide Magnetic Flowmeter Material Selection Guide www.sparlinginstruments.com Introduction The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter.

More information

excellent performance spherical and sharp particle size distribution persistence and highest quality

excellent performance spherical and sharp particle size distribution persistence and highest quality ISO 00 Certified Working to enhance quality management excellent performance spherical and sharp particle size distribution persistence and highest quality offeres packing materials and packed, under strict

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

column If you would like a subscription, or more information, please contact your nearest Waters Office.

column If you would like a subscription, or more information, please contact your nearest Waters Office. column Waters A Reprint from Spring 99 If you would like a subscription, or more information, please contact your nearest Waters Office. Check the Waters website for up-to-date information: http://www.waters.com

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Ion Analysis of Hydraulic Fluids in Fracking Process

Ion Analysis of Hydraulic Fluids in Fracking Process Ion Analysis of Hydraulic Fluids in Fracking Process Presented by Jay Gandhi *, PhD Metrohm USA NEMC-2013 1 NEMC-2013 2 What we will cover today Background Hydraulic Fracking Ion Analysis Applications

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,

More information

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

Acclaim HPLC and UHPLC Columns

Acclaim HPLC and UHPLC Columns Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC

The Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC The Analysis of rganic Acids in Foods and Beverages Using Reversed Phase HPLC Rebecca E. Wittrig & Terrence S. Reid Restek Corporation Benner Circle, Bellefonte, PA 683 USA Restek Corporation www.restekcorp

More information

INERTSIL (GL Sciences)

INERTSIL (GL Sciences) Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

Theory of Ion Chromatography

Theory of Ion Chromatography Theory of Ion Chromatography The ideal method for analyzing anions, cations and polar substances is ion chromatography. It can be used to reliably quantify substances throughout a wide concentration range.

More information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume

More information

Data Pack. Ion Chromatography Methods. June 2009

Data Pack. Ion Chromatography Methods. June 2009 Data Pack Ion Chromatography Methods June 2009 Table of Contents Introduction. 2 Ion Chromatography Methods List. 3 Inorganic Anions in Waters..7 Inorganic Anions in High Purity Waters..15 Inorganic Disinfection

More information

PRODUCT MANUAL. ACCLAIM OA GUARD COLUMN 4.3 x 10 mm, P/N ACCLAIM OA ANALYTICAL COLUMN 4 x 250 mm, P/N x 150 mm, P/N

PRODUCT MANUAL. ACCLAIM OA GUARD COLUMN 4.3 x 10 mm, P/N ACCLAIM OA ANALYTICAL COLUMN 4 x 250 mm, P/N x 150 mm, P/N PRODUCT MANUAL for the ACCLAIM OA GUARD COLUMN 4.3 x 0 mm, P/N 0695 ACCLAIM OA ANALYTICAL COLUMN 4 x 50 mm, P/N 0690 4 x 50 mm, P/N 06903 QUICKSTART STEPS AND LINKS Click blue text below to get started..

More information

Appendix 5: table of chemical compatibility for tubing

Appendix 5: table of chemical compatibility for tubing Appendix 5: table of chemical compatibility for tubing KEY 1 Excellent 2 Good 3 Fair 4 Not recommended - no data Silicone PharMed Iso-Versinic PVC Acetaldehyde 3 4 4 2 Acetamide, 67% in w 1 2 4 4 Acetate

More information