1 HPLC COLUMNS & Bulk Resins THE MEASURE OF EXCELLENCE TM
2 The Measure of Excellence Hamilton For nearly 0 years, Hamilton Company has been satisfying customer needs in the field of precision fluid measuring. It all started with syringes. Not commercial, mass produced medical syringes, but precision measuring instruments. About years ago Hamilton was the first company to develop and manufacture pressure stable polymeric HPLC columns. Columns We now offer 9 different polymer-based HPLC columns for reversed phase, anion exchange, cation exchange and ion exclusion separations. Two silica-based C8 and C8 columns are available for reversed phase separations. Choosing the Right HPLC Column Before you select an HPLC column to separate your sample please check the Hamilton Company HPLC web site at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated on Hamilton HPLC columns.
3 This brochure only contains a few of the applications which have been performed on Hamilton HPLC columns. In the brochure, columns are grouped by separation mechanism: reversed phase, anion exchange, cation exchange and ion exclusion. The Recommended Uses Table below lists a few of the possible uses for each of the column packings. Recommended Uses Reversed Phase PRP -h Long life column for LC/MS applications,synthesized DNA, and small molecule PRP-h PRP- PRP- PRP-Infinity HxSil C8, C8 Reduced system pressure for protein and peptide separations and enhanced oligonucleotide recovery General purpose ph stable long life column, synthesized DNA Gradient protein and peptide separations Nonporous support for very fast gradient separation of large proteins General purpose silica-based reversed phase Anion Exchange PRP-X00 Anions, inorganic and organic using conductivity or UV detection. 0 to 00% solvent compatible. PRP-X0 PRP-X00 PRP-X600 RCX-0 RCX-0 Similar to PRP-X00 but for lower level anions (0 ppb to 0 ppm) Gradient separation of large proteins and labeled DNA Gradient separation of labeled and unlabeled DNA Isocratic or gradient separation of carbohydrate oligomers up to DP8 Gradient separation of complex carbohydrates Cation Exchange PRP-X00 Inorganic and organic cations using conductivity or UV detection. Separate mono or divalent cations depending on mobile phase conditions. PRP-X00 PRP-X800 HC-0 HC-7 HC-7 HC-7 Glyphosate and metabolite in drinking water. Also unique hydrophilic interaction separations Mono and divalent cations in the same run. Transition metals Sugar oligomers up to DP8. Max pressure,000 psi Mono and disaccharides in corn syrup. Max pressure,000 psi Calcium Form Organic acids and sugars. Max pressure,000 psi Hydrogen Form Sugar alcohols. Max pressure,000 psi Lead Form Ion Exclusion PRP-X00 Organic acids and alcohols
4 USP L Numbers & Bulk Resins USP "L" Number and Hamilton USP "L" Number HAMILTON Column L L7 L7 L9 L L L Octadecylsilane chemically bonded to porous silica or ceramic micro-particles, to 0 µm in diameter. Octylsilane chemically bonded to porous silica particles, to 0 µm in diameter. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to µm in diameter. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, about 9 µm in diameter. A rigid, spherical styrene-divinylbenzene copolymer, to 0 µm in diameter. An anion-exchange resin made of porous polymethacrylate or polyacrylate gel with quaternary ammonium groups, about 0 µm in size. Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the lead form, about 9 µm in diameter. HxSil C8 HxSil C8 HC-7 Hydrogen Form HC-7 Calcium Form PRP- PRP- PRP-X00 HC-7 Lead Form Bulk Resins Reversed Phase Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-h PSDVB* N/A 00 Å 7979 PRP-h PSDVB* N/A 00 Å 7980 PRP- PSDVB* N/A 00 Å PRP- PSDVB* N/A 00 Å HxSil C8 Silica HxSil C8 Silica Anion Exchange Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-X00 PSDVB* with Trimethyl- 0.9 meq/gm 00 Å ammoniun Exchanger PRP-X00 Poly(methacryl-.6 meq/gm Superfi amidopropryl Trimethyl- cially ammonium chloride porous PRP-X600 Poly(dimethyl-.6 meq/gm Superfi amidopropyl-methacryl- cially amide) porous Cation Exchange Support Exchange Pore Supports Material Capacity Size µm µm 7 µm 0 µm -0 µm 0-0 µm 0-7µm PRP-X00 PSDVB* with Sulfonate µeq/gm 00 Å Exchanger PRP-X00 PSDVB* with Sulfonate. meq/gm N/A Exchanger * PSDVB is Poly(styrene-divinylbenzene) Bulk resin is sold by the gram.
5 PRP - Reversed Phase Reversed Phase PRP -h Polymeric 00 Å columns for reversed phase, LC/MS applications. ph stable from to. Low bleed (ideal for mass spectrometry). Robust (virtually any HPLC solvent can be used). One particle size: µm. Four column diameters:.,.6, 0 and 00 mm. Analytical and semiprep/preparative guard columns. Benzoic Acid and its Derivatives PRP-h, µ, 00 Å,. x 0 mm.,-dihdroxybenzoic Acid. -Hydroxybenzoic Acid. -Acetoxybenzoic Acid (Aspirin). Benzoic Acid. - Hydroxybenzoic Acid (Salicylic Acid) Naproxen Sodium PRP-h, µm, 00 Å,. x 0 mm,. Naproxen (0 µg/ml). Ibuprofen (80 µg/ml) I.D. 0 mm 00 mm 0 mm 0 mm. mm mm mm mm Mobil Phase: A: 0 mmol/l sodiumdihydrogenphosphate ph =. B: Acetonitrile. Gradient: 8% B (Isocratic) Flow Rate:0.60 ml/min. Column Temperature: 0 o C Detection: nm. Injection Volumn: µl Analytical Guard Columns Starter Kit 797 ( holder, cartridges) Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm Semiprep/Preparative Guard Column Starter Kit 797 ( holder, cartridge) Replacement Cartridges (/pk) 7976 *** Semiprep/preparative guard column for steel columns is.6 x 0 mm 0 Mobil Phase: A: 0 mmol/l Sodiumdihydrogenphosphate ph = B: Acetonitrile. Gradient: Isocratic 0% A/0%B Flow Rate:0.60 ml/min. Column Tempera ture: 60 o C Detection: nm. For Steel Columns* For Steel Columns***
6 PRP-h Reversed Phase Polymeric 00 Å columns for oligonucleotide purification and protien separations. ph stable from to. Robust (virtually any HPLC solvent can be used). Hydrophilic polymer structure delivers faster oligonucleotide purification. -mer Oligonucleotide Purification PRP-h, PRP-h,. x µ, 0 00 mm, Å,. µm x 0 00 mm Å One particle size: µm. Three column diameters:.,.6 and 0 mm. Analytical and semiprep/preparative guard columns Mobile phase: A: 0. mol/teaa,ph = 7 B: 0. mol/l TEAA, ph = 7, % Acetonitrile Gradient: 0-80 %B in min. Flow Rate: 0.60 ml/min Column Temp: 60 o C Detection: 60 nm I.D. 0 mm 00 mm 0 mm 0 mm. mm mm mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Analytical Guard Columns Starter Kit 7967 ( holder, cartridges) Replacement Cartridges (/pk) 7968 * Analytical guard column for steel columns is. x 0 mm Semiprep/Preparative Guard Column Starter Kits 7977 ( holder, cartridge) Replacement Cartridges (/pk) 7978 *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns* For Steel Columns***
7 PRP- Reversed Phase Polymeric 00 Å columns for general reversed phase separations. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (stable to any concentration of water or organic solvent). Five particle sizes:, 7, 0, -0 and 0-0 µm. Eleven column internal diameters:.0 to 0.6 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Small Molecules DNA with Secondary Structure Biocides found in Soap PRP-,. x 0 mm, µm (P/N 7980) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Cytosine. Uracil. Uridine. Failure Sequences. -DMT 6mer. Chloroxylenol 00 ppm. Triclocarban 00 ppm Seconds Conditions: 0.0M Citric Acid ph.. Isocratic. Ambient. ml/min. 0 µl, UV nm Conditions: A) 0mM Sodium Hydroxide ph.7; B) : 0mM Sodium Hydroxide : Acetonitrile. Linear Gradient 0% B (0- min), 0-0% B (- min). 60 C. ml/min. UV 60nm Conditions: : Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 6
8 PRP- Reversed Phase Surfactant Surfactant Fatty Acids PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 00 mm, µm (P/N 7980). Sodium Octadecylsulfate 00 ppm. Sodium Dodecylsulfate 00 ppm. Caproic Acid. Caprylic Acid. Capric Acid. Lauric Acid. Palmitic Acid 6. Stearic Acid 6 0 Conditions:.:. Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity Conditions: :7 Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity 0 0 Conditions: A) : Acetonitrile : Water; B) Acetonitrile. Linear Gradient 0-00% B in min. Hold for min. Ambient. 0. ml/min. 0 µl, UV nm. Isomeric C8 Fatty Acids Chlorhexidine Gluconate Resveratrol PRP-,. x 0 mm, 7 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Linolenic Acid (C8:). Linoleic Acid (C8:). Oleic Acid (C8:). Stearic Acid (C8:0). Chlorhexidine Gluconate µg. Resveratrol Conditions: 0.% Trifluoroacetic Acid in 9: Acetonitrile : Water. Isocratic. Ambient. 0.8 ml/min. 00 µl, UV 0 nm. 0 6 Conditions: :0:69 Trifluoroacetic Acid : Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. µl, UV nm Conditions: :7 Acetonitrile : 0.M Sodium Dihydrogen Phosphate ph.. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. Pyridinoline Diphenylguanidine Folic Acid PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 0 µm (P/N 79) PRP-,. x 0 mm, 7 µm (P/N 79). Pyridinoline, mg/ml. Diphenylguanidine mg/ml. Folic Acid 0 Conditions: :9 Acetonitrile : Deionized Water with 0.% Heptafluorobutyric Acid. Isocratic. Ambient. ml/min. µl, UV 80 nm. 0 Conditions: :8 Acetonitrile : Deionized Water with 0. % Trifluoroacetic Acid. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. 0 0 Conditions: 97.:. 0mM Sodium Phosphate ph 6. : Acetonitrile. Isocratic Ambient. ml/min. µl, UV 80 nm. 7
9 PRP- Reversed Phase Pregnenolone and Pregnenolone--sulfate Water Soluble Vitamins Fat Soluble Vitamins PRP-,. x 0 mm, 7 µm (P/N 79). Pregnenolone--sulfate. Pregnenolone PRP-,. x 0 mm, 0 µm (P/N 79). Niacinamide. Pyridoxine (B6). Thiamine (B). Riboflavin (B). Cyanocobalamine (B) PRP-,. x 0 mm, 7 µm, (P/N 79). Retinol (Vitamin A) 00 ppm. Calciferol (Vitamin D) 0 ppm. alpha-tocopherol (Vitamin E) 0 ppm. Phylloquinone (Vitamin K) 0 ppm 0 0 Conditions: 7: Acetonitrile : mm Tetrabutylammonium Hydrogensulfate. Isocratic. Ambient. ml/min. 0 µl, UV 0 nm Conditions: A) 0.N Perchloric Acid; B) Acetonitrile. Linear Gradient -0%B in 0 min. Ambient. ml/min. 0 µl, UV 0 nm Conditions: 0:70:0 Tetrahydrofuran : Acetonitrile : Water. Isocratic. Ambient.. ml/min. 00 µl, UV 80 nm. I.D. x Length µm 7 µm 0 µm -0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm* x 0 mm x mm 79789**. x 0 mm 79. x 00 mm x 0 mm x 0 mm x 0 mm* x 00 mm* x 0 mm* * PEEK hardware ** Cartridge Column, Cartridge Holder P/N 908 must be purchased separately. I.D. x Length µm 7 µm 0 µm -0 µm 0-0 µm.6 x 0 mm* x 00 mm x 00 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm x 00 mm x 0 mm x 0 mm x 0 mm 79 Analytical Guard Columns For Steel Columns* For PEEK Columns** Semiprep/Preparative Guard Column For Steel Columns*** Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 79 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. 8
10 PRP- Reversed Phase Polymeric 00 Å columns for protein separations. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (the support can be cleaned with strong acid or base to remove any sample residue). Two particle sizes: 0 and -0 µm. Eight column internal diameters:.0 to 0.8 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Proteins PRP-,. x 0 mm, 0 µm (P/N 7966). Ribonuclease A. Cytochrome c. Lysozyme. Myoglobin. Ovalbumin 0 8 Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient -0% B in min. Hold min. Ambient. ml/min. 00 µl, UV nm. Proteins at ph. PRP-,. x 0 mm, 0 µm (P/N 7966) Ribonuclease A.0 mg/ml. Insulin.0 mg/ml. Cytochrome c.0 mg/ml. Trypsin.0 mg/ml. Lysozyme.0 mg/ml 6. Pyruvate Dehydrogenase 0. mg/ml Conditions: A) 0.% TFA in 0mM Sodium Hydroxide ph.; B) 0.% TFA in Acetonitrile. Linear Gradient 0-60% B in 0 min. Ambient. ml/min. 0 µl, UV 0 nm. I.D. x Length 0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm. x 00 mm x 0 mm 799. x 0 mm x 00 mm I.D. x Length 0 µm -0 µm. x 0 mm x 0 mm x 0 mm* x 0mm* x 0 mm* x 0 mm x 0 mm 796. x 0 mm x 0 mm 7987 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Semiprep/Preparative Guard Column For Steel Columns* Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 79 9 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm
11 PRP-Infinity Reversed Phase Polymeric nonporous packing for fast gradient separation of large proteins. ph stable from to. Better sample recovery than silica-based columns (there are no silanol groups). Excellent durability (the support can be cleaned with strong acid or base to remove any sample residue). One particle size: µm. Three column internal diameters:. to 0.0 mm. One column material: 6 stainless steel. Proteins PRP-Infinity,. x mm, µm (P/N 7970). Ribonuclease A. Cytochrome c. Transferrin. Bovine Serum Albumin. Concanavalin A 6. Ovalbumin 6 Proteins PRP-Infinity,. x mm, µm (P/N 7970) 6. Ribonuclease A. Cytochrome c. Transferrin. Bovine Serum Albumin. Concanavalin A 6. Ovalbumin I.D. x Length µm. x mm x 00 mm x mm x 0 mm x 60 mm 797 For PRP-Infinity columns an in-line filter is recommended as a guard column is not available. 0 0 Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient 0-60% B in 0 min. Ambient. ml/min. 0 µl, UV nm Conditions: A) 0.% TFA in Water ph.0; B) 0.% TFA in Acetonitrile. Linear Gradient -60% B at 0.6% per second. Ambient. ml/min. 0 µl, UV nm. Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. 0
12 HxSil C8 & C8 Reversed Phase Silica-based 00 Å columns for general reversed phase separations. Separation of closely related PAHs. Better retention of poorly retained compounds. Separation of neutral, acidic and basic compounds without tailing (tailing factor of less than.0). Two particle sizes: and µm. Five column internal diameters:. to. mm. Analytical and semiprep/preparative guard columns in 6 stainless steel. Sunscreens in Lip Balm Sunscreen Compounds Diphenhydramine in Itch Relief Gel HxSil C8,.6 x 0 mm, µm (P/N 79868). Oxybenzone. Octocrylene. Octyl Methoxycinnamate. Avobenzone (Parsol 789). Octyl Salicylate HxSil C8,.6 x 0 mm, µm (P/N 79868). -Hydroxy-- methoxybenzophenone. -Ethylhexyl trans-- methoxycinnamate. -Ethylhexylsalicylate HxSil C8,.6 x 0 mm, µm (P/N 79868). Diphenhydramine 0 ppm Conditions: 8: Methanol : Water. Isocratic. Ambient. ml/min. ul, UV 08 nm. 0 0 Conditions: 7: Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 0 Conditions: 9: Methanol : 0mM Potassium Hydrogen Phosphate ph 7.0. Isocratic. Ambient. ml/min. µl, UV nm. Meclizine in Tablets Tetracycline by USP Method Oxytetracycline and Tetracycline HxSil C8,.6 x 0 mm, µm (P/N 79868) HxSil C8,.6 x 0 mm, µm (P/N 79869) HxSil C8,.6 x 0 mm, µm (P/N 790). Meclizine mg/ml. Tetracycline 0. mg/ml. Oxytetracycline 0. mg/ml. Tetracycline 0. mg/ml 0 0 Conditions: 9: Methanol : 0mM Potassium Hydrogen Phosphate ph 7.0. Isocratic. Ambient. ml/min. µl, UV nm Conditions: 680 ml 0.N Ammonium Oxalate, 70 ml Dimethylformamide, 0 ml 0.M Dibasic Ammonium Phosphate ph 7.6. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm. 0 0 Conditions: 680 ml 0.N Ammonium Oxalate, 70 ml Dimethylformamide, 0 ml 0.M Dibasic Ammonium Phosphate ph 7.6. Isocratic. Ambient. ml/min. 0 µl, UV 80 nm.
13 HxSil C8 & C8 Reversed Phase Folic Acid, Methotrexate by USP Method Antibiotics Small Molecules HxSil C8,.6 x 0 mm, µm (P/N 79868) 0 0 Conditions: 9: 0.6M Sodium Phosphate, Dibasic, 0.07M Citric Acid ph 6.0 : Acetonitrile. Isocratic. Ambient.. ml/min. 0 µl, UV 0 nm.. Folic Acid 00 µg/ml. Methotrexate 00 µg/ml HxSil C8,.6 x 0 mm, µm (P/N 790). Ampicillin. Oxacillin. Dicloxacillin 0 0 Conditions: : 0.0M Potassium Phosphate ph 7 : Acetonitrile. Isocratic. Ambient. ml/min. µl, UV nm. HxSil C8,.6 x 0 mm, µm (P/N 79868) 6. Uracil. Caffeine. Phenol. Toluene. Butylbenzene 6. Triphenylene 7. Amylbenzene 8. Terphenyl Conditions: 7: Acetonitrile : Water. Isocratic. Ambient. ml/min. 0 µl, UV nm. 7 8 HxSil C8 I.D. x Length µm µm. x mm 796. x 0 mm x 7 mm x 00 mm x 0 mm x 0 mm 79.6 x mm 79 I.D. x Length µm µm.6 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm 790. x 0 mm 7906 Analytical Guard Column For Steel Columns* Semiprep/Preparative Guard Column For Steel Columns* Starter Kit 798 Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) 79 Replacement Cartridges (/pk) 796 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm HxSil C8 I.D. x Length µm µm. x mm x 0 mm x 7 mm x 00 mm x 0 mm x 0 mm x mm I.D. x Length µm µm.6 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm x 0 mm 7987 Analytical Guard Column For Steel Columns* Semiprep/Preparative Guard Column For Steel Columns* Starter Kit 799 Starter Kit 797 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) 79 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm * Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.
14 Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride from the water dip. Use with organic solvent from 0 to 00 % for elution of hydrophobic anions or column cleaning. ph stable from to. Use conductivity or UV detection. Three particle sizes:, 0 and -0 µm. Eight column internal diameters:.0 to 0.8 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Common Anions Anions by Indirect UV Detection EDTA PRP-X00,. x 0 mm, µm (P/N 7980). Fluoride. Chloride. Nitrite. Bromide. Nitrate PRP-X00,. x 0 mm, 0 µm (P/N 79). Fluoride 0 ppm. Carbonate 0 ppm. Chloride 0 ppm. Nitrite 0 ppm. Bromide 0 ppm 6. Nitrate 0 ppm 7. Phosphate 0 ppm 8. Sulfate 0 ppm PRP-X00,.6 x 0 mm, 0 µm (P/N 79). Copper EDTA 0 ppm Conditions: mm p-hydroxybenzoic Acid ph 8. w/.% Methanol ml/min. 00 µl, Conductivity Conditions: mm p-hydroxybenzoic Acid ph 8.9 with. % Methanol. Isocratic. Ambient. ml/min. 00 µl, Indirect UV 0 nm. 0 6 Conditions: mm Sulfuric Acid. Isocratic. Ambient. ml/min. 00 ul, UV nm.
15 PRP-X00 Anion Exchange Organic Acids Germall Bromate and Other Anions PRP-X00,. x 0 mm, 0 µm (P/N 79). Formic Acid 0 µg. Fluoroacetic Acid 0 µg. Isopropylmethyl Phosphonic Acid 0 µg. Chloroacetic Acid 0 µg PRP-X00,.6 x 0 mm, 0 µm (P/N 79),. Germall mg/ml PRP-X00,. x 0 mm, 0 µn (P/N 79). Fluoride 0 ppm. Chloride 0 ppm. Bromate 0 ppm. Bromide 0 ppm. Nitrate 0 ppm 0 0 Conditions: 0.M Sodium Hydroxide in :9 Acetonitrile : Deionized Water. Isocratic. Ambient. ml/min. 0 µl, Conductivity. 0 0 Conditions: 7: 0mM Sodium Hydroxide : Methanol. Isocratic. Ambient. ml/min. 0 µl, UV 0 nm Conditions:.7mM Sodium Bicarbonate,.8mM Sodium Carbonate, 0.mM Sodium Thiocyanate. Isocratic. Ambient. ml/min. 0 µl, Suppressed Conductivity. Sulfite and Sulfate Phosphate and Phosphite Chlorite and Chlorate PRP-X00,.6 x 0 mm, 0 µm (P/N 79). Sulfite.7 mg/ml. Sulfate 0. mg/ml PRP-X00,. x 0 mm, 0 µm (P/N 79). Fluoride 0 ppm. Phosphate 0 ppm. Phosphite 0 ppm. Chloride 0 ppm PRP-X00,. x 0 mm, 0 µm (P/N 79) Fluoride. Chlorite. Chloride. Nitrite. Phosphate 6. Bromide 7. Nitrate 8. Chlorate 0 6 Conditions: 80:0 8mM p-hydroxybenzoic Acid ph 0.0 : Methanol. Isocratic. Ambient. ml/min. 0 µl, Conductivity Conditions: 0mM Succinic Acid ph.9. Isocratic. Ambient. ml/min. 00 µl Conductivity Conditions:.0mM -Amino--Hydroxybenzoic Acid ph.8. Isocratic. Ambient. ml/min.00 µl, Indirect UV 0 nm. I.D. x Length µm 0 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm 79. x 0 mm* x 0 mm x 0 mm 796. x 00 mm x 0 mm 79 I.D. x Length µm 0 µm -0 µm. x 0 mm x 0 mm* x 0 mm* x 0 mm x 0 mm x 0 mm 79. x 00 mm 79. x 0 mm 79. x 0 mm x 0 mm 79 PEEK hardware Analytical Guard Columns For Steel Columns** For PEEK Columns*** Semiprep/Preparative Guard Column For Steel Columns**** Starter Kits Starter Kit 79 ( holder, cartridges) ( holder, cartridge) Replacement Cartridges (/pk) Replacement Cartridges (/pk) 796 ** Analytical guard column for steel columns is. x 0 mm *** Analytical guard column for PEEK columns is.0 x 8.0 mm **** Semiprep/preparative guard column for steel columns is.6 x 0 mm
16 PRP-X0 Anion Exchange Polymeric anion exchange packings for separation of inorganic and organic anions from 0 ppb to 0 ppm. Good separation of fluoride from the water dip. Compatible with conductivity or UV detectors. Use with organic solvent up to 00% ph stable from to. Anions One particle size: 7 µm. Four column internal diameters:.0 to.6 mm. Polarizable Anions Two column materials: 6 stainless steel and PEEK. Analytical guard columns. Glucaric Acid PRP-X0,. x 0 mm, 7 µm (P/N 797) 6 7. Fluoride ppm. Chloride ppm. Nitrite ppm. Bromide ppm. Nitrate ppm 6. Phosphate ppm 7. Sulfate ppm PRP-X0S,. x 0 mm, 7 µm (P/N 797) 6. Fluoride ppm. Chloride ppm. Iodide 0 ppm. Sulfate 0 ppm. Thiosulfate 0 ppm 6. Perchlorate 0 ppm PRP-X0,. x 0 mm, 7 µm (P/N 797). Glucaric Acid 000 ppm 0 8 Conditions:.0mM p-hydroxybenzoic Acid ph 9.. Isocratic. Ambient. ml/min. 00 µl, Non-Suppressed Conductivity. 0 7 Conditions: mm Sodium Hydroxide with mm Phenol, 0.0mM Sodium Thiocyanate. Ambient.. ml/min. 0 µl, Suppressed Conductivity. 0 6 Conditions: :7 Acetonitrile : 0mM Potassium Phosphate, ph 6.. Isocratic. Ambient.. ml/min. 0 µl, UV 0 nm. PRP-X0 PRP-X0S I.D. x Length 7 µm 7 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 00 mm* x 0 mm* x 0 mm* x 00 mm x 0 mm x 0 mm PRP-X0 PRP-X0S I.D. x Length 7 µm 7 µm.6 x 00 mm* x 0 mm* x 0 mm* * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm
17 PRP-X00 Anion Exchange Polymeric strong-base anion exchange packing with limited porosity for separation of proteins. Fast separation of large proteins. ph stable from to. One particle size: 7 µm. Three column internal diameters:. to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Higher sample capacity than nonporous supports. DMT-on Antisense Phosphorothioate 8mer PRP-X00,.6 x 0 mm, 7 µm (P/N 797). DMT-on Phosphorothioate 8mer Proteins PRP-X00,.6 x 0 mm, 7 µm (P/N 797). Myoglobin 7 µg. Conalbumin 7 µg. Dog Albumin 77 µg Conditions: A) 8: 00mM TRIS ph 8.0 : Acetonitrile; B) 8: 00mM TRIS ph.0,.m Lithium Chloride : Acetonitrile. Linear Gradient 0-00% B in 0 min. ml/min. 00 µl of a mg/ml solution, UV 60nm. 0. Conditions: A) 0mM Tris ph 9.0; B) 0mM Tris ph 9.0, 0.N Sodium Chloride. Linear Gradient 0-0% B in. min. Hold for. min. Ambient. ml/min. 0 µl, UV nm. I.D. x Length 7 µm. x 0 mm* x 0 mm 79.6 x 0 mm* x 0 mm* x 00 mm 798 Analytical Guard Column For PEEK Columns* Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 790 * Analytical guard column for PEEK columns is.0 x 8.0 mm * PEEK hardware 6
18 PRP-X600 Anion Exchange Polymeric weak-base anion exchange packing for gradient separation of proteins and DNA oligomers. Limited porosity allows separation of large DNA fragments. ph stable from to. One particle size: 7 µm. Column material: PEEK. Guard column in PEEK. Higher sample capacity than nonporous supports. Separation of DNA Fragments DMT-on Phosphorothioate 8mer Proteins PRP-X600,.6 x 0 mm, 7 µm (P/N 7960) PRP-X600,.6 x 0 mm, 7 µm (P/N 7960). DMT-on Phosphorothioate 8mer PRP-X600,.6 x 0 mm, 7 µm (P/N 7960). Myoglobin mg/ml. Concalbumin mg/ml. Ovalbumin mg/ml. Bovine Serum Albumin mg/ml Conditions: A) 0mM TRIS, mm EDTA ph 9.0; B) N NaCl in A, Linear Gradient % B in min. 67.%-7% B (- min.). Ambient. ml/min. µl, UV 60 nm Conditions: A) 8: 00mM TRIS ph 8.0 : Acetonitrile; B) 8: 00mM TRIS ph.0,.m Lithium Chloride : Acetonitrile. Linear Gradient 0-00% B in 0 min. ml/min. UV 60 nm. 0 7 Conditions: A) 0mM TRIS ph 9.0; B) 0mM TRIS, ph 9.0,.0M Sodium Chloride. Linear Gradient 0 to %B in 0 min. Hold min. ml/min. UV 0nm. 7 I.D. x Length 7 µm.6 x 0 mm* x 00 mm* x 0 mm* x 0 mm* 7989 * PEEK hardware Analytical Guard Column For PEEK Columns* Starter Kit ( holder, cartridges) 796 Replacement Cartridges (/pk) 796 * Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.
19 RCX-0 Anion Exchange Polymeric anion exchange packing for isocratic or gradient separation of carbohydrates. ph stable from to. Isocratic separation of mono and disaccharides. Gradient separation of oligomers up to DP8. Compatible with PAD, conductivity and RI detectors. One particle size: 7 µm. Three column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in stainless steel and PEEK. Glycols in Water Acetyl Glucosamine Artichoke Tubers RCX-0,. x 0 mm, 7 µm (P/N 790). Ethylene Glycol 00 ppb. Propylene Glycol 00 ppb 0 8 Conditions: 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 0 µl, Pulsed Amperometric, Dual Gold Electrode. E=60 mv T=66 msec E=900 mv T=66 msec E=-800 mv T=00 msec RCX-0,. x 0 mm, 7 µm (P/N 790). Galactosamine 00 ppm. Glucosamine 00 ppm. Acetyl-Glucosamine 00 ppm 0 7 Conditions: 0mN Sodium Hydroxide (purged with Helium during the run) Isocratic. Ambient. ml/min. 0 µl, Refractive Index. RCX-0,. x 0 mm, 7 µm (P/N 790). DP. DP. DP0. DP 0 0 Conditions: A) 60mM Sodium Hydroxide; B) 60mM Sodium Hydroxide with 00mM Sodium Acetate. Gradient: 0-00%B in 0 min. ml/min. 0 µl, Pulsed Amperometric, Dual Gold Electrode E=00 mv T= msec E=800 mv T=66 msec E=-600 mv T=99 msec I.D. x Length 7 µm. x 0 mm x 0 mm x 0 mm* 7988 Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm 8
20 RCX-0 Anion Exchange Polymeric anion exchange packing for isocratic or gradient separation of complex carbohydrates. ph stable from to. Isocratic or gradient modes. Higher ion exchange capacity support for separation of closely related carbohydrates. Compatible with PAD and RI detectors. One particle size: 7 µm. Three column internal diameters:.,. and.6 mm. Two column materials: Stainless steel and PEEK. Guard column in PEEK. Glycoprotein Monosaccharides Corn Syrup Artichoke Tubers RCX-0,.6 x 0 mm, 7µm (P/N 7970). Fucose. Galactosamine. Glucosamine. Galactose 6. Glucose 6. Mannose RCX-0,.6 x 0 mm (P/N 7970) Glucose. Fructose. Maltose. Maltotriose. Maltotetraose 6. Maltopentaose 7. Maltohexaose 8. Maltoheptaose 9. Maltooctaose RCX-0,.6 x 0 mm (P/N 7970). Glucose. Fructose. Sucrose. DP. DP0 6. DP Conditions: 6mN Sodium Hydroxide. Isocratic. Ambient. ml/min. µl, Pulsed Amperometric µafs Dual Gold Electrode E=600 mv T=66 msec E=600 mv T=66 msec E=-800 mv T=9 msec Conditions: A) 60mM Sodium Hydroxide; B) 00mM Sodium Acetate in A. Linear Gradient 00% A for min., then 0-00% B (- min.) Ambient. ml/min. 0 µl. Pulsed Amperometric Dual Gold Electrode. E=0 mv T=66 msec E=900 mv T=66 msec E=-80 mv T=00 msec Conditions: A) 60mM Sodium Hydroxide; B) 00mM Sodium Acetate in A. Linear Gradient: 0-0% B in 0 min., then 0-00% B (0-0 min.). Ambient. ml/min. 0 µl, Pulsed Amperometric Dual Gold Electrode. E=0 mv T=66 msec E=900 mv T=66 msec E=-800 mv T=00 msec 9 I.D. x Length 7 µm Analytical Guard Column For PEEK Columns*. x 0 mm 7970 Starter Kit ( holder, cartridges) 797. x 0 mm 7980 Replacement Cartridges (/pk) x 0 mm* 7970 * Analytical guard column for PEEK columns is.0 x 8.0 mm.6 x 0 mm* * PEEK hardware Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.
21 Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent up to 00% for elution of hydrophobic cations and column cleaning. Compatible with conductivity and UV detectors. One particle size: 0 µm. Six column internal diameters:.0 to 0.0 mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Monovalent Cations Glycine and Ethanolamine N-Methylglucamine PRP-X00,. x 0 mm (P/N 79). Lithium. Sodium. Ammonium. Potassium. Cesium PRP-X00,. x 0 mm (P/N 79). Glycine. Sodium. Ethanolamine PRP-X00,. x 0 mm (P/N 79). N-Methylglucamine mg/ml 0 0 Conditions:.: mm Nitric Acid: Methanol. Isocratic. Ambient. ml/min. 00 µl, Conductivity. 0 6 Conditions: mn Nitric Acid. Ambient. Isocratic. ml/min. 0 µl, Conductivity. 0 8 Conditions: mn Nitric Acid. Isocratic. Ambient. ml/min. µl, Conductivity. I.D. x Length 0 µm I.D. x Length 0 µm.0 x 0 mm x 0 mm 79.0 x 00 mm x 0 mm 79.0 x 0 mm x 0 mm* 79.0 x 0 mm x 0 mm* 798. x 0 mm x 0 mm* 797. x 0 mm x 0 mm x 00 mm x 0 mm 799 * PEEK hardware * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) Semiprep/Preparative Guard Column Starter Kits ( holder, cartridge) 797 Replacement Cartridges (/pk) 798 * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 m *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For Steel Columns*** 0
22 PRP-X00 Cation Exchange Polymeric cation exchange packing for separation of glyphosate and its metabolite in drinking water. Faster analysis when compared to competitor s columns. Detection levels of less than 0 ppb when using the post column, OPA derivatization technique. Applicable to other separations, such as inositol and sugar alcohols. Two particle sizes: 7 and -0 µm. Five column internal diameters:. to. mm. Two column materials: 6 stainless steel and PEEK. Analytical and semiprep/preparative guard columns. Glyphosate and Metabolite Inositol in Vitamin Matrix Sugar Alcohols PRP-X00,. x 0 mm, 7 µm (P/N 797). Glyphosate. Aminomethylphosphonic Acid PRP-X00,. x 0 mm, 7 µm (P/N 797),,, and. Unknown. Inositol PRP-X00,. x 0 mm, 7 µm (P/N 797). Adonitol 00 ppm. Arabitol 00 ppm. Xylitol 00 ppm. Mannitol 00 ppm. Sorbitol 00 ppm 0 6 Conditions: 0.00M Monobasic Potassium Phosphate. Isocratic. Ambient. 0. ml/min. 00 µl, Excitation wavelength 8 nm. Emission wavelength nm. Post Column Conditions: Oxidation Solution Flow Rate: 0.0 ml/min; Reaction Coil: ml (0.0 cm ID X m); Reaction Time:. min; Temp: 8 C Derivatization Solution: 0.0 ml/min; Reaction Coil: 0.0 ml (0.0 cm ID X m), Ambient. Conditions: 8: Acetonitrile : 0mN Sodium Hydroxide. Isocratic. Ambient. ml/min. 00 µl, Pulsed Amperometric Dual Gold Electrode. E=00 mv T=76 msec E=000 mv T=66 msec E=-800 mv T=99 msec Post Column Conditions: 0.N Sodium Hydroxide solution at ml/min Conditions: A) Acetonitrile; B) Water. Linear Gradient 0-0% B in 0 min. Ambient. ml/min. µl, Pulsed Amperometric Dual Gold Electrode; delay 0 msec E=00mV T=70msec E=000mV T=0msec E=-800mV T=00msec Post Column Conditions: 0.N Sodium Hydroxide at ml/min. I.D. x Length 7 µm -0 µm. x 0 mm x 0 mm x 0 mm x 0 mm x 0 mm* x 0 mm 797. x 0 mm 79 * PEEK hardware Analytical Guard Column Starter Kit ( holder, cartridges) 7976 Replacement Cartridges (/pk) 7977 C8 Guard Column for EPA Glyphosate Application Starter Kit ( holder, cartridges) 799 Replacement Cartridges (/pk) 79 PRP-X00 Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 79 Replacement Cartridges (/pk) 79 * Analytical guard column for PEEK columns is.0 x 8.0 m ** Analytical guard column for steel columns is. x 0 mm *** Semiprep/preparative guard column for steel columns is.6 x 0 mm For PEEK Columns* For Steel Columns** For Steel Columns***
23 PRP-X800 Cation Exchange Polymeric cation exchange columns for the isocratic separation of mono and divalent cations. Isocratic separation of lithium, sodium, ammonium, potassium, magnesium and calcium. Gradient separation of transition metals. Excellent durability (stable to any concentration of water or organic solvent). One particle size: 7 µm. Two column internal diameters:. to.6 mm. Two column materials: 6 stainless steel and PEEK. Guard columns in 6 stainless steel and PEEK. Mono and Divalent Cations Transition Metals Transition Metals PRP-X800,. x 0 mm, 7 µm (P/N 7988). Lithium ppm. Sodium ppm. Ammonium ppm. Potassium ppm. Magnesium ppm 6. Calcium ppm 0 6 Conditions: mm Cupric Sulfate. Isocratic. Ambient. 0.8 ml/min. 0 µl, Indirect UV 0 nm. 6 PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Cadmium 6 ppm. Zinc 6 ppm. Cobalt 6 ppm Conditions: A) 0mM Ammonium Acetate. ph.; B) Trifluoroacetic Acid in Water ph.. Linear Gradient -% B in 0 min. ml/min. 00 µl, Post Column Reaction: 0.0% -(-pyridylazo)resorcinol in M Ammonium Hydroxide 0. ml/min. Visible 0 nm. PRP-X800,. x 0 mm, 7µm (P/N 798). Manganese 6 ppm. Zinc 6 ppm. Cadmium 6 ppm. Lead 6 ppm Conditions: A). mm Ethylenediamine ph.; B) 00mM Ethylenediamine ph.7. Linear Gradient 00% A (0- min.), 0-00% B in (-0 min.) ml/min, 00 µl, Post Column Reaction: 0.0% -(-pyridylazo) resorcinol (PAR) in M Ammonium Hydroxide, 0. ml/min. Visible 0 nm. I.D. x Length 7 µm. x 0 mm 798. x 0 mm x 0 mm* x 0 mm* 7989 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated.
24 HC-0 Cation Exchange Polymeric % cross-linked soft-gel column for cation, ligand exchange separation of carbohydrates. Separate oligosaccharides up to DP8. Water mobile phase. Compatible with RI detectors. One particle size: 0 - µm. One column internal diameter: 7.8 mm. One column material: 6 stainless steel. Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79) 76. Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltooctaose + High Conversion Corn Syrup HC-0, 7.8 x 0 mm, (P/N 79). Glucose. Maltose. Maltotriose. Maltotetraose. Maltopentaose 6. Maltohexaose 7. Maltoheptaose Conditions: Water. Isocratic. 80 C. 0.6 ml/min. µl, Refractive Index Conditions: Deionized Water. Isocratic. 80 C. 0.6 ml/min. 0 µl, Refractive Index. Guard Columns For Steel Columns* Gel-Type Cation Exchange Column I.D. x Length 0- µm 7.8 x 0 mm 79 Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-0 guard column for steel columns is.6 x 0 mm
25 HC-7 Cation Exchange Polymeric 7.% cross-linked soft-gel columns for cation, ligand exchange separations of carbohydrates. Compatible with UV and RI detectors. Hydrogen form columns for USP L7 applications. Calcium form columns for USP L9 applications. Lead form columns for USP L applications. One particle size: 9 µm. Three column internal diameters:., 7.8 and 0.0 mm. One column material: 6 stainless steel. Three forms: calcium, lead and hydrogen. Malic Acid Citric, Lactic and Acetic Acids Dihydroxyacetone HC-7,. x 0 mm H + (P/N 7976). Maleic Acid ppm. Malic Acid 000 ppm. Fumaric Acid 0 ppm HC-7,. x 0 mm H + (P/N 7976). Citric, Acid 0 ppm. Lactic Acid 0 ppm. Acetic Acid 0 ppm HC-7, 7.8 x 0 mm Ca + (P/N 796). Formic Acid 0. mg/ml. Glycerol 0. mg/ml. Dihydroxyacetone 0. mg/ml 0 0 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 6 Conditions: 0.0N Sulfuric Acid. Isocratic. 60 C. 0. ml/min. 0 µl, UV 0 nm. 0 0 Conditions: 0.0M Calcium Chloride. Isocratic. 90 C. 0.6 ml/min. ul, Refractive Index. Gel-Type Cation Exchange Columns 9 µm, 9 µm, 9 µm, I.D. x Length Calcium Lead Hydrogen. x 0 mm x 00 mm x 0 mm x 0 mm 798 Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com for a complete list of compounds that have been separated. Guard Columns Hydrogen Form Cation Exchange Starter Kit ( holder, cartridge) 79 Hydrogen Form Cation Exchange Replacement Cartridges (/pk) 79 Carbonate Form Anion Exchange Starter Kit ( holder, cartridge) Carbonate Form Anion Exchange Replacement Cartridges (/pk) 7986 * HC-7 guard column for steel columns is.6 x 0 mm For Steel Columns*
26 Ion Exclusion PRP-X00 Polymeric ion exclusion packing for separation of alcohols and organic acids. Separate structurally similar alcohols. Separate similar organic acids. Use with organic solvent from 0 to 00% for elution of highly retained compounds. One particle size: 7 µm. Two column materials: 6 stainless steel and PEEK. Five column internal diameters:.0 to 0.0 mm. Analytical and semiprep/preparative guard columns. Fatty Acids Acrylamide and Acrylic Acid Organic Acids PRP-X00,. x 0 mm (P/N 796). Acetic Acid 00 ppm. Propionic Acid 00 ppm. Isobutyric Acid 00 ppm. Butyric Acid 00 ppm. Isovaleric Acid 00 ppm 6. Valeric Acid 00 ppm 6 PRP-X00,. x 0 mm (P/N 796). Acrylamide ppm. Acrylic Acid 0 ppm. Acrylonitrile 67 ppm PRP-X00,. x 0 mm (P/N 796). Tartaric Acid. Malic Acid. Citric Acid. Lactic Acid. Acetic Acid Conditions: 0:80 t-butyl Alcohol : 0mM Potassium Phosphate Monobasic ph.. Isocratic. Ambient. ml/min. 00 µl, UV nm. 0 6 Conditions: 9: mn Sulfuric Acid : Acetonitrile. Isocratic. Ambient. ml/min. µl, UV 0 nm. 0 6 Conditions: mn Sulfuric Acid. Isocratic. Ambient. ml/min. 0 ul, UV 0 nm. I.D. x Length 7 µm.0 x 0 mm x 00 mm x 0 mm x 0 mm x 0 mm x 0 mm x mm 796. x 0 mm 796. x 0 mm 796. x 0 mm x 0 mm* x 0 mm* x 0 mm 797 * PEEK hardware Analytical Guard Columns For Steel Columns* For PEEK Columns** Starter Kits ( holder, cartridges) Replacement Cartridges (/pk) * Analytical guard column for steel columns is. x 0 mm ** Analytical guard column for PEEK columns is.0 x 8.0 mm Semiprep/Preparative Guard Column Starter Kit ( holder, cartridge) 799 Replacement Cartridges (/pk) 790 * Semiprep/preparative guard column for steel columns is.6 x 0 mm Visit the HAMILTON Application Compound Index at or chromatography@hamiltoncompany.com For Steel Columns*
Anion Exchange HPLC Columns
Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride
More informationCation Exchange HPLC Columns
Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationHPLC. Columns and Resins. For a Complete Range of Applications
HPLC Columns and Resins For a Complete Range of Applications 0 HPLC COLUMNS AND RESINS HAMILTON Polymeric and Silica-Based Packings for a Complete Range of HPLC Separations To order products from this
More informationH P L C C O L U M N S
H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil
More informationgroups I and II cations, amines, divalent transition metals
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationIC Columns Introduction
IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,
More informationMethod Development with ZirChrom's Ion Exchange Phases
For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than
More informationHPLC Columns and Accessories. Solutions for liquid chromatography
HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance
More informationHPLC Columns and Accessories. Solutions for liquid chromatography
HPLC Columns and Accessories Solutions for liquid chromatography Innovation and excellence in chromatography Hamilton Company has been developing and manufacturing pressure-stable polymeric high performance
More informationZirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,
More informationDionex IonPac AS28-Fast-4µm column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column
More informationcolumns IonPac AS17-C Anion Exchange Column
columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column
More informationcolumns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s
columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationINSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE
INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)
More informationcolumns IonPac AS18 Anion-Exchange Columns
columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,
More informationFast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger
Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Pittcon 2005 BINGWEN YAN 1, CLAYTON V. MCNEFF 1, 1 ZirChrom Separations, Inc., 617 Pierce Street,
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationNew Product Update. HPLC Columns
New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna
More informationThermo Scientific. Anion-Exchange Column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is
More informationSaccharides and Organic Acids
Saccharides and Organic Acids Contents Introduction... 2 Reducing Sugars... 2 HILIC The HILICpak and Ashipak Series... 3 Shodex HILIC Columns for Sugar Analysis... 7 Ligand Exchange Shodex SUGAR series...
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationSepax SRT -C, Zenix -C SEC Phases
Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based
More informationAnalysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography
Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens
More informationIC Section. Starter Kits IC SPE Standards EZ-LUTE Buffers Other Accessories
IC Section IC Columns..............................304-316 Introduction..............................305-306 Allsep Anion Columns...................... 307 Novosep Anion Columns.................... 308
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationThermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column
Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm
More informationThermo Scientific Dionex IonPac AS23 Anion-Exchange Column
Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for
More informationcolumns IonPac AS22 Anion-Exchange Column
columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride,
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationTSKgel Size Exclusion Chromatography Columns
Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:
More informationInertsil ODS-EP Technical Information
Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationInertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases
HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica
More informationAcclaim Mixed-Mode WAX-1 Columns
User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,
More informationMethod Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationNew On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography
New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure
More informationCh.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)
Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high
More informationcolumns IonPac SCS 1 Silica Cation Separator
columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly
More informationAQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase
AQUASIL C8 Columns AQUASIL 8 Columns TG0-0 Compatible with 00% aqueous mobile phase AQUASIL OH OH AQUASIL C8 columns provide a versatile C8 phase for a wide range of application areas. AQUASIL C8 columns
More informationAcclaim HILIC-10 Columns
Thermo Scientific Acclaim HILIC- Columns Product Manual P/N: January 3 Part of Thermo Fisher Scientific Product Manual for Acclaim HILIC- Analytical Column Acclaim HILIC-, 3 µm, Analytical, 4.6 x 5 mm
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationHigh Performance Liquid Chromatography
Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN
More informationThermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationThermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific
Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0
More informationThe Evolving HPLC Column Packings
The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established
More informationProPac WCX-10 Columns
ProPac WCX-10 Columns Guidance for column use Tips to maximize column lifetime ProPac WCX-10 Column Tips and Tricks This guide provides essential information and invaluable guidelines for mobile phases,
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Catalogue 9 Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationMedia Compatibility Guide PVC Valves
73 F (23 C) Valves WARNING This chart indicates the suitability of various elastomers and plastics for use with fluids to be conveyed. It should be used only as a guide for the selection of valve materials.
More informationThermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes
columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationAn HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint
An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar
More informationanion-exchange column
columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationPacked columns for reversed-phase chromatography TSKgel ODS-100V and 100Z
Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationIC5000 Ion Chromatography System
IC000 Ion Chromatography System Quaternary gradient pumping and on-line eluent preparation to improve separations in complex samples In-line sample filtration to 0.8 µm to eliminate manual filtrations
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More information500 SERIES CHEMICAL RESISTANCE GUIDE
500 SERIES CHEMICAL RESISTANCE GUIDE INTRODUCTION The Stonchem 500 Series Chemical Resistance Guide is designed to aid in the proper selection of material for every job application. Exposure to over 250
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationSuperior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection
columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior
More informationMagnetic Flowmeter Material Selection Guide
Magnetic Flowmeter Material Selection Guide www.sparlinginstruments.com Introduction The purpose of this guide is to provide a general resource for the selection of materials for the magnetic flowmeter.
More informationexcellent performance spherical and sharp particle size distribution persistence and highest quality
ISO 00 Certified Working to enhance quality management excellent performance spherical and sharp particle size distribution persistence and highest quality offeres packing materials and packed, under strict
More informationComparison of different aqueous mobile phase HPLC techniques
June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active
More information4. Ion chromatography (IC) 4.1. Educational aims and objectives
4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.
More informationIon Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin
Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the
More informationAdvantages of polymerbased. an alternative for ODS
Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:
More informationcolumn If you would like a subscription, or more information, please contact your nearest Waters Office.
column Waters A Reprint from Spring 99 If you would like a subscription, or more information, please contact your nearest Waters Office. Check the Waters website for up-to-date information: http://www.waters.com
More informationNovel LC/MS-Compatible Stationary Phase with Polar Selectivity
Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based
More informationThermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column
chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationOptical Isomer Separation Columns and Packing Materials
02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationInertSustainSwift C8
Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)
More informationUsing a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components
APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,
More informationQUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3
Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long
More informationIon Analysis of Hydraulic Fluids in Fracking Process
Ion Analysis of Hydraulic Fluids in Fracking Process Presented by Jay Gandhi *, PhD Metrohm USA NEMC-2013 1 NEMC-2013 2 What we will cover today Background Hydraulic Fracking Ion Analysis Applications
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationRapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography
Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,
More informationEfficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System
Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationAcclaim HPLC and UHPLC Columns
Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical,
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationSmall Molecule Selectivity Sampler
Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles
More informationThe Analysis of Organic Acids in Foods and Beverages Using Reversed Phase HPLC
The Analysis of rganic Acids in Foods and Beverages Using Reversed Phase HPLC Rebecca E. Wittrig & Terrence S. Reid Restek Corporation Benner Circle, Bellefonte, PA 683 USA Restek Corporation www.restekcorp
More informationINERTSIL (GL Sciences)
Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationP R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns
P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns
More informationTheory of Ion Chromatography
Theory of Ion Chromatography The ideal method for analyzing anions, cations and polar substances is ion chromatography. It can be used to reliably quantify substances throughout a wide concentration range.
More informationNo.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page
No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume
More informationData Pack. Ion Chromatography Methods. June 2009
Data Pack Ion Chromatography Methods June 2009 Table of Contents Introduction. 2 Ion Chromatography Methods List. 3 Inorganic Anions in Waters..7 Inorganic Anions in High Purity Waters..15 Inorganic Disinfection
More informationPRODUCT MANUAL. ACCLAIM OA GUARD COLUMN 4.3 x 10 mm, P/N ACCLAIM OA ANALYTICAL COLUMN 4 x 250 mm, P/N x 150 mm, P/N
PRODUCT MANUAL for the ACCLAIM OA GUARD COLUMN 4.3 x 0 mm, P/N 0695 ACCLAIM OA ANALYTICAL COLUMN 4 x 50 mm, P/N 0690 4 x 50 mm, P/N 06903 QUICKSTART STEPS AND LINKS Click blue text below to get started..
More informationAppendix 5: table of chemical compatibility for tubing
Appendix 5: table of chemical compatibility for tubing KEY 1 Excellent 2 Good 3 Fair 4 Not recommended - no data Silicone PharMed Iso-Versinic PVC Acetaldehyde 3 4 4 2 Acetamide, 67% in w 1 2 4 4 Acetate
More information