1 Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area silica which is specially manufactured to provide maximum bonded phase coverage. The result is a series of columns which provide excellent peak shapes using simple eluents while operating at low pressure. Inertsil Series 3 phases Phase Endcapped Particle Size (µm) Pore Size (Å) Surface Area (m 2 /g) Carbon Load (%) SIL-100Å - 3, ODS-3 Yes 2, 3, 4, ODS-3V Yes ODS-P No ODS-EP No Peptide C18 Yes Proprietary ODS-Sprint Yes 3, Sulfa C18 Yes 3, C8-3 Yes 2, 3, Ph-3 No 2, 3, CN-3 No NH2 No Diol No HILIC No AX No CX No Inertsil ODS-3 Excellent reproducibility Exceptional stability and column lifetime Low column back pressure Ultra pure and rigid silica Rigorous physical property tests High inertness High reproducibility with longer column life Rigorous quality control of the physical properties of the base silica, proprietary bonding and endcapping chemistry, as well as excellent chromatographic tests for inertness and selectivity, contribute to the production of columns with good reproducibility and long column lifetimes. The inherent lower column back pressure of Inertsil ODS-3 enables a 5µm, 250mm x 4.6mm column to be operated below 10Mpa even when using water/methanol as the mobile phase. Now available in 2µm for UHPLC, see page 139 for ordering information Rigorous tests for base silica Inertsil base silica is manufactured using the purest reagents available, in a process that excludes contaminants during the formation of the silica bead structure. The resulting base silica is ultra pure and shows improved efficiency and sample recovery for samples that interact with metals. The silica particles are rigid and have a smooth surface, preventing structural fragmentation when operated at pressures in excess of 30Mpa. To ensure extremely low metal levels of the silica, analysis by Atomic Emission and ICP is applied to every batch. Scanning Electron Microscopy is also used for the assurance of the surface smoothness. Particle sizes are measured by Nitrogen Adsorption and Laser Ray Particle Analyzer. Every batch of synthesized silica gel is subject to rigorous inspection, and only those batches meeting the strict specifications are used for the subsequent bonding procedure. 142

2 Inertsil ODS-3 (continued) High inertness It is well known that residual silanol groups on the surface of the silica gel will cause severe peak tailing and adsorption, especially with nitrogen-containing compounds. In the production of Inertsil ODS-3, the silanols are eliminated through a proprietary bonding-endcapping technology developed at GL Sciences. To ensure maximum inertness, each batch of Inertsil ODS-3 must pass a new quality control program using 29 Si NMR. The 29 Si NMR spectrum (Fig. 1 next page) shows that isolated silanols on Inertsil ODS-3 packings have been completely eliminated, thereby ensuring excellent inertness and optimum performance of the phase. There are many new generation ODS phases on the market which still show residual silanols using this test. Inertsil ODS-3 shows excellent inertness for both basic and acidic compounds. In addition, chelating compounds also elute with good peak shape owing to the high purity of the base silica. As typical examples of these compound types, pyridine, ethylaniline, benzylamine and aminopyridine (basic compounds), formic acid and acetic acid (acids) and oxine copper (chelating compound) are generally employed for QC tests. Good peak shapes are obtained on Inertsil ODS-3 columns. Conversely, there are many columns on the market which are referred to as new generation columns but show significant tailing for these compounds (see Fig. 2). High durability A long column lifetime is one of the most important factors contributing to cost efficiency of an analysis. In general, routine use in the ph range of 2 to 7.5 is recommended for silica-based packings. The durability of Inertsil ODS-3 at ph 2 and ph9 has been tested. The graph below shows the variations in retentivity of naphthalene on Inertsil ODS-3 compared with other ODS columns. Inertsil ODS-3 was stable at ph 2 (0.1% TFA) over 500 hours. Figure 1. Comparison of commercially available ODS packings, using 29 Si NMR spectra (referenced from previous page) Figure 2. Comparison between ODS-3 and commercially available ODS columns Comparison between ODS-3 and commercially available ODS columns Formatic Acid and Acetic Acid TEST Column Size: 250mm x 4.6mm Eluent: 0.1% H 3 PO 4 (v/v) Flow: 1.0mL/min Temp: 40 C Detection: UV210nM Inj. Vol: 4µL Sample: 1. Formic Acid 0.1% (v/v) 2. Acetic Acid 0.1% (v/v) Inertsil ODS-3 ODS-A ODS-B ODS-C ODS-D 143

3 Inertsil ODS-3V A validated Inertsil column Validated LC analysis requires validated instruments and LC columns. Unless your column is manufactured in a validated process, especially when changing from old to new columns, your analytical results may vary significantly and a time-consuming preparation of validation documents has to be completed on all such occasions. Inertsil ODS-3V columns are already validated and include a Manufacturerʼs Validation Certificate so that you can eliminate unnecessary work. GL Sciences has developed a program to manufacture, test and guarantee validated high performance LC columns that offer complete reliability from column to column, batch to batch, time after time. 1) the absence of surface silanols 2) minimal metallic residues 3) inertness to basic compounds 4) reproducible separations In Figure 1 the separation of a series of antidepressant drugs demonstrates the inert nature of Inertsil ODS-3. Figure 1. Separation of antidepressant drugs on Inertsil ODS-3V Norephedrine 2. Nortriptyline 3. Toluene 4 4. Imipramine 5. Amitriptyline 3 5 Each lot of packing undergoes a series of critical analytical tests to confirm: Inertsil ODS-P Polymerically bonded C18 Improved separation of planar compounds Useful for carotenoid anaylsis Separation of the 16 EPA PAHs Column dimensions: 250mm x 4.6 (mm) Flow rate : 1ml/min. Eluent : CH 3 OH - 25mM KH 2 PO 4, ph 6 (60:40) Temperature : 25 C Figure 2. Separation of toad venom 3 1. Bufalin 2 Inertsil ODS-P is a polymerically bonded phase which is densely bonded with octadecylsilane groups. It shows unique separation capabilities and offers an alternative selectivity to Inertsil ODS-3. Inertsil ODS-P is particularly suited to the separation of polycyclic aromatic hydrocarbons, and shows additional retentivity for planar compounds Cinobufagin Figure 2 shows the separation of components from toad venom. Figure 3 shows the separation of terphenyl isomers on the three types of ODS phases. On the polymeric Inertsil ODS-P phase, the planar p-terphenyl is retained longer than the non-planar o- and m- isomers. Figure 3. Separation of terphenyl isomers minutes Column: Inertsil ODS-P (250mm x 4.6mm) Eluent: CH 3 CN - 0.1% H 3 PO 4 (45:55) Flow rate: 1ml/min Temperature: 40 C o-terphenyl (non-planar) m-terphenyl (non-planar) p-terphenyl (planar) Column: Inertsil ODS-P (150mm x 4.6mm) Eluent: CH 3 CN - H 2 O (85:15) Flow rate: 1ml/min Temperature: 40 C p- o- m- m- p- o- m- o- p- minutes minutes minutes Monomeric (Intersil ODS-3) Intermediate (Intersil ODS-2) Polymeric (Intersil ODS-P) 144

4 Inertsil ODS-EP C18 with polar embedded group Compatible with 100% aqueous eluents Alternative selectivity to C18 Ideal for LC-MS Inertsil ODS-EP contains a polar functional group embedded between the silica surface and the C18 group. The embedded polar group makes the C18 phase stable in 100% aqueous eluents without phase collapse. This phase is also extremely base deactivated and provides superior peak shape for acids and bases in organic eluents as well as acidified eluents typically used in LC-MS. Figure 1. Naphthalene sample for retention and peak shape comparison Column : Inertsil ODS-EP, 5µm, 150mm 4.6mm Mobile Phase: Acetonitrile:Water = 64:35 Detection: UV254 nm Peak identification 1. Acetophenone 2. Benzene 3. Toluene 4. Naphthalene Figure 2. Selectivity test sample comparison Column : Inertsil ODS-EP, 5µm, 150mm 4.6mm Mobile Phase: Acetonitrile:Water = 70:30 Detection: UV265 nm Peak identification 1. Ethylbenzene 2. Naphthalene 3. n-propylbenzene 4. n-butylbenzene 5. Anthracene Figure 3. Tanaka test sample (Comparison of hydrogen bonding capacity, hydrophobicity and selectivity) Column : Inertsil ODS-EP, 5µm, 150mm 4.6mm Mobile Phase: Methanol:Water = 80:20 Detection: UV254 nm Peak identification 1. Uracil 2. Caffeine 3. Phenol 4. n-butylbenzene 5. n-amylbenzene 6. o-terphenyl 7. Triphenylene 145

5 Inertsil HILIC Hydrophilic Interaction Chromatography is a variation of normalphase mode where a high concentration of non-polar solvent is used in a mobile phase. It is an ideal method for separating and retaining highly polar analytes unretained by traditional reversedphase mode. HILIC columns become widely used for critical separations in demanding drug metabolism, drug discovery and combinatorial chemistry. In addition, volatile mobile phases are used for HILIC mode and afford enhanced ESI-MS sensitivity resulting in lower limits of detection. Application for HILIC mode - Amino acids - Water-soluble vitamins - Drug metabolites and drug discovery - Combinatorial chemistry - Promoted retention of compounds unretained by reversedphase mode Advantages of HILIC mode - Low column back pressure analyses can be performed due to high organic solvent composition - A high organic solvent concentration of the mobile phase will lead to a high sensitivity LC-MS analysis - The benefit of less ion suppression effect in LC-MS analysis - Precision determination for polar compounds due to the fast elution of hydrophobic contents Figure 2. Water soluble vitamins Column : Inertsil HILIC 5µm, 250mm 3.0mm Eluent : Acetonitrile (0.1% TFA)/H 2 O (0.1% TFA) = (90/10), (80/20), (60/40), 20/80) Flow Rate : 0.4 ml/min Detection: UV 254 nm Sample Size: 20µL Sample: 1. Thiamine (8ppm) 2. Nicotinamide (8ppm) 3. L-Ascorbic acid (80ppm) 4. Riboflavin (8ppm) Figure 1. Separation of oligosaccharide Column : Inertsil HILIC, 5µm, 150mm 4.6mm Mobile Phase : Acetonitrile/H 2 O (85:15, w/w) Detection: RI Peaks: 1. Maltose 2. Maltotriose 3. Maltotetraose 4. Maltopentaose 5. Maltohexaose 6. Maltoheptaose Figure 3. Amino acids Column : Inertsil HILIC 5µm, 250mm 3.0mm Eluent : Acetonitrile 10mM KH 2 PO4 (10%ACN) = (85/15),(80/20),(70/30),(50/50),(30/70) Flow Rate : 0.4 ml/min Detection: UV 210 nm Sample Size: 1mL Sample: 1. Phenylalanine (100ug/mL) 2. Methionine (500ug/mL) 3. Valine (4mg/mL) 4. Alanine (4mg/mL) 5. Serine (8mg/mL) 146

6 Inertsil ODS-Sprint Well balanced retention of both polar and non polar compounds Superior inertness and base deactivation Compatible with completely aqueous or neat organic eluents Low operating back pressure 20mm x 2.1mm column with new Sprint HG hardware is ideal for rapid LC-MS separations Moderate retentivity GL Sciencesʼ newly developed chemical bonding technology allows Inertsil ODS-Sprint to retain hydrophilic compounds, but elutes hydrophobic compounds faster. It offers 1/2 of Inerstil ODS-3 retention for hydrophobic compounds (see Figure 1). Figure 1. Elution of hydrophobic compounds Column : Inertsil ODS-SP, 5µm, 250mm 4.6mm Mobile Phase: CH 3 OH/H 2 O = 80/20, v/v Detection: UV254 nm) Inertsil ODS-Sprint is an important new addition to the Inertsil 3 column series. Inertsil ODS-Sprint is extremely base deactivated and optimally bonded to retain polar compounds without excessive retention of non-polar compounds. This allows you to achieve improved separations faster. ODS-Sprint operates at low back pressure even at high flow rates, shows outstanding longevity and is reproducible from column to column and batch to batch. To complement this new phase, GL Sciencesʼ has created a zero-dead-volume column hardware format, known as Sprint-HG hardware, further enhancing peak symmetry. For additional information, please contact Canadian Life Science. Short equilibration time A highly uniformed low carbon loading ODS enables shorter equilibration time for gradient analysis and can be used for highthroughputs. The time for purging and cleaning the column can be reduced in isocratic analysis. In Figure 2, Inertsil ODS-SP shows a complete equilabration after 10 mins with stable retentivity. Figure 2. Equilibration time comparison Column : Inertsil ODS-SP, 5µm, 250mm 4.6mm Mobile Phase: CH 3 CN/H 2 O = 5/95 (5min hold) - (7min) - 100/0 (5min hold),v/v Detection: UV215 nm Sample: 1. Methamidophos 2. Acephate 147

7 Inertsil ODS-Sprint Sharp peak shape Sharp peak shapes can be observed due to GL Sciencesʼ newlydeveloped bonding technology and column hardware. 3µm packed columns are also available for further sharp peak shapes. Inertsil ODS-sprint does not show any tailing with complete base line separation, resulting in excellent quantitative determination. Peak tailing of large volume compounds (unreacted derivatizing reagent) disturbed the detection of the target compound on Competitor E, F and G columns (see Figure 3). Figure 3. Analysis of derivatized products Column : Inertsil ODS-SP, 5µm, 150mm 4.6mm Mobile Phase: CH 3 CN/H 2 O = 55/45, v/v Sample 1. DNPH-Formadehyde Detection: UV360 nm) 2. DNPH-Acetoaldehyde No adsorption of peaks GL Sciencesʼ intensive endcapping is performed to eliminate residual silanols, creating an exceptionally inert column for reverse-phase chromatography. Excellent peak shapes for a wide range of polar analytes, including both basic and acidic compounds, can be obtained. Inertsil ODS-Sprint shows excellent peak shapes of basic and acidic compounds. Other competitorʼs columns are showing tailing peaks of both compounds. Some columns may be able to analyze basic compounds, but show peak tailing for acidic compounds (see Figure 4). Figure 4. Analysis of basic compounds Column : Inertsil ODS-SP, 5µm, 250mm 4.6mm Mobile Phase: CH 3 OH/20mM Phosphate buffer (ph 7.6) = 10/90, v/v Sample Detection: UV254 nm 1. 4-aminopyridine 2. 3-aminopyridene 3. 2-aminopyridine Stable performance To retain water-soluble organic compounds, the use of mobile phases that contain little or no organic modifier are sometimes needed. Under these highly aqueous conditions, Inertsil ODS-Sprint shows excellent reproducible retention behaviour and high resistance to buffer or acid additives from lot-to-lot (see Figure 5). Figure 5. Stop-flow test using 100% water eluent Testing procedure 1) 1 st analysis conducted after introducing eluent for 20 minutes 2) Stop flow for 15 minutes 3) 2 nd analysis conducted after introducing eluent for 10 minutes 4) Stop flow for 15 minutes Column : Inertsil ODS-SP, 5µm, 250mm 4.6mm Sample Mobile Phase: H 3 O Cytosine 2. Uracil 3. Guanine Detection: UV254 nm) 4. Thymine 5. Adenine 148

8 Sulfa C18 Analysis of antibiotic drugs and drug residues in products of animal origin has become an important element of ensuring food safely. Inertsil Sulfa C18 is suitable not only for the analysis of sulfa drugs but also for the screening of synthetic antibacterial agents which are directed in the food safety investigative guidelines. Figure 1. Analysis of 15 sulfa reagents Figure 2. Inertness comparison Column : Inertsil Sulfa, 5µm, 250mm 4.6mm Mobile Phase: 0.1% H 3 PO 4 v/v Detection: UV210 nm Sample Size: 4 µl Sample 1) Formic Acid 0.1% (v/v) 2) Acetic Acid 0.1% (v/v) Antibacterial agents, including sulfa drugs, consist of polar functional groups which can cause adsorption on the packing material. High inertness to basic and acidic compounds enables Inertsil Sufa C18 to effectively analyze antibacterial agents. Each batch of Inertsil Sulfa C18 is tested for the effective separation of sulfa drugs, as shown in Figure 1 below, and is provided with a copy of the chromatogram. System: GL-7400 LC SYSTEM Column : Inertsil SULFA C18, 3µm, 150mm 4.6mm Eluent : A) CH 3 CN/ CH 3 COOH = /3.15, w/w B) CH 3 COOH/H 2 O = 3.15/997, w/w A/B - 0/100-33min- 33/67-3min- 90/10-4min- 90/10 Flow Rate: 1.0mL/min Detection: UV 270 nm Injection Vol: 10µL Sample: 1. Sulfanilamide 8. Sulfamethoxypyridazine 2. Sulfacetamide 9. Sulfamonomethoxine 3. Sulfadiazine 10. Sulfachlorpyridazine 4. Sulfathiazole 11. Sulfamethoxazole 5. Sulfapyridine 12. Sulfabenzamide 6. Sulfameradine 13. Sulfadimethoxine 7. Sulfacymidine 14. Sulfaquinoxalin 15. Sulfanitran Column : Inertsil Sulfa, 5µm, 250mm 4.6mm Mobile Phase: 0.1% CH 3 OH/ H 2 O 30/70 Detection: UV254 nm Sample Size: 4 µl Sample 1) Pyridine 0.09 mg/ml 2) Phenol 0.41 mg/ml Figure 3. Analysis of antibacteria agents directed in the food sanitation investigation guideline 149

9 Inertsil Diol Unique selectivity in both reversed-phase and normal-phase Applications for amino acids, water-soluble vitamins and sugars The Inertsil Diol phase is a dihydroxypropyl bonded silica which can be used in both reversed-phase and normal-phase modes. The retentivity is higher than that of silica in normal-phase mode. Figure 1 shows the analysis of free amino acids on an Inertsil Diol column. Inertsil Peptide C18 The new Inertsil Peptide C18 column was developed for the analysis of Peptide mapping. 100Å pore size high purity silica gels are bonded with octadecyl groups and the residual silanols are drastically reduced. Metabolic analysis to Peptide analysis are performed with great reproducibility on Inertsil Peptide C18. Figure 2 shows the application of this column for the analysis of cytochrome C tryptic digest. Figure 2. Analysis of cytochrome C on Inertsil Peptide C18 Figure 1. Analysis of free amino acids Column: Inertsil Diol (250mm x 4.6mm) Eluent: CH 3 CN - H 2 O (80:20) Flow rate: 1ml/min Temperature: 40 C 1. Phenylalanine 2. Methionine 3. Valine 4. Dopa 5. Alanine 6. Serine 7. Citrulline Inertsil AX (Anion Exchange), CX (Cation Exchange) High theoretical plate number Silica base anion exchange columns High reproduciblity Exceptional stability and long column lifetime AX bonded phase structure Improved stability versus conventional SAX and SCX columns such as Partisil SAX, SCX CX bonded phase structure Figure 3. Adenosine and adenosine mono phosphate 150

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Inertsil Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

RP C18 column with feature of a silanol group

RP C18 column with feature of a silanol group RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

State - of - the -art C18 HPLC Columns

State - of - the -art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based

More information

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chemistry Instrumental Analysis Lecture 28. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 28 High Performance Liquid Chromatography () Instrumentation Normal Phase Chromatography Normal Phase - a polar stationary phase with a less polar mobile phase.

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

UPLC Method Development and Validation

UPLC Method Development and Validation UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy

More information

The Selection of an HPLC Column October

The Selection of an HPLC Column October The Selection of an HPLC Column 07. ctober Long-Term Collaboration + 30 Years of Experience GL Sciences Inc. HPLC Selection of an HPLC Column 3 Contents. How to Select an HPLC Column How to select your

More information

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB Use of An Improved Version of C8+SCX Mixed-Mode Solid Phase Extraction Material for Clean Extraction and Recovery of Basic, Zwitterionic, Neutral and Acidic Compounds from Biological Fluids Yuhui Yang,

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

C18 Column. Care & Use Sheet

C18 Column. Care & Use Sheet C18 Column Care & Use Sheet HALO Description HALO C18 is a high-speed, high-performance liquid chromatography column based on a new Fused-CoreTM particle design. The Fused-Core particle provides a thin

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WAX-1 Columns User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

NUCLEOSHELL core-shell silica for HPLC

NUCLEOSHELL core-shell silica for HPLC NUCLESHELL core-shell silica for HPLC Core-shell technology µm 0. µm.8 µm 0. µm.7 µm 0. µm.7 µm 0. µm Key feature Solid core of silicon dioxide, homogeneous shell of porous silica Highest efficiency compared

More information

Passion. Power. Productivity.

Passion. Power. Productivity. - - Passion. Power. Productivity. Acclaim Acclaim Acclaim PA/PA Acclaim A Acclaim Acclaim PA Acclaim Explosives rdering and Warranty Information In the U.S. All rders Including: Credit Card rders (VISA,

More information

LC Columns with Liquid Separation Cell Technology

LC Columns with Liquid Separation Cell Technology Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,

More information

design: black sheep t: Reliable & reproducible performance every time - Guaranteed

design: black sheep t: Reliable & reproducible performance every time - Guaranteed design: black sheep t: 029 2049 0722 Reliable & reproducible performance every time - Guaranteed Accurate & quantitative data Affordable price Reproducibility Wide application range HPLC Column Requirements

More information

HPLC Column Classification

HPLC Column Classification HPLC Column Classification Introduction 1978 USP XIX Fourth supplement : L1 designation for C18 column 1980 USP XX : 7 columns were classified -Classified HPLC column to 56 descriptions -More than 220

More information

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000 Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ] ultimate efficiency unleashed [ Cortecs columns ] [ CORTECS UPLC COLUMNS ] A SUB--µm SOLID-CORE PARTICLE COLUMN THAT LIVES UP TO ITS POTENTIAL. C 8 + C 8 HILIC SOLID-CORE PARTICLE COLUMNS THAT DELIVER

More information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs) A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary

More information

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase AQUASIL C8 Columns AQUASIL 8 Columns TG0-0 Compatible with 00% aqueous mobile phase AQUASIL OH OH AQUASIL C8 columns provide a versatile C8 phase for a wide range of application areas. AQUASIL C8 columns

More information

A C18 Silica Column With Exceptional Temperature and ph Stability

A C18 Silica Column With Exceptional Temperature and ph Stability A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies,

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

Do you need trouble-free speed? The NEW Chromolith HR

Do you need trouble-free speed? The NEW Chromolith HR Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns

More information

CAPCELL PAK C18 IF2 Type http://hplc.shiseido.co.jp/e/column/html/if2_index.htm Page 1 of 2 List of Sales Representatives Contact Shiseido Technical Materials Catalog List HPLC Columns HPLC Instruments

More information