HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

Size: px
Start display at page:

Download "HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited"

Transcription

1 HICHROM Chromatography Columns and Supplies LC COLUMNS Catalogue 9 Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0) Fax: + (0) sales@hichrom.co.uk

2 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk SHODEX Silica- and polymer-based phases Columns for all chromatographic modes Wide application range Capillary, microbore, analytical and preparative dimensions Showa Denko K.K., Japan manufactures the line of HPLC columns for the pharmaceutical and biotechnology industries. A wide range of products with both silica-based and polymer-based materials is available. An overview of the products is shown on the following pages: reversed-phase (page 0), ligand exchange (page ), ion-exchange and ion chromatography (page ), size exclusion (page ), HIC (page ) and affinity (page ). Please enquire for additional details. Reversed-Phase Columns The product range contains both polymer-based and silica-based phases. Please enquire for ordering details where not listed. Reversed-Phase (Polymer-based) Phases The table below lists the polymer-based phases available. RSpak RP8, DS Styrene-divinylbenzene - Analysis of proteins and peptides RSpak DE, GOLF, CARB Polymethacrylate - DE series columns have similar selectivity to C8 columns RSpak DM-6 Polyhydroxymethacrylate - Suitable for analysis of amino acids and polypeptides RSpak NN Polyhydroxymethacrylate Sulpho Suitable for separation of mixtures of neutral and ionic RSpak JJ-50 Polyvinyl alcohol Quaternary ammonium compounds Asahipak ODP Polyvinyl alcohol Octadecyl Asahipak ODP HP Polyhydroxymethacrylate Octadecyl Large pore size phases, suitable for high molecular weight compounds eg. proteins, as well as low molecular weight Asahipak C8P-50 Polyvinyl alcohol Octyl compounds. LC-MS applications Asahipak CP-50 Polyvinyl alcohol Butyl Asahipak NHP Polyvinyl alcohol Amino Analysis of saccharides (NP) ODP HP is a macroporous polyhydroxymethacrylate reversed-phase material offering better efficiencies than many other resin-based phases and comparable to that of silica-based C8 columns. It has a recommended ph range of to. The high polarity and small pore size (0Å) of this phase is designed to exclude proteins and can be used for the analysis of drugs in biological samples ie. as restricted access material (see Figure for example). Blank switch valve introduce to MS UV, 0nm with BSA BSA switch valve introduce to MS UV, 0nm Sample: 5μl : 500μg/l BSA: 7.0mg/ml Mins Mins SIM : m/z=8 Peak Area : 00% SIM : m/z=8 Peak Area : 99% Column: ODP HP-B (50 x.0mm) Eluent:0mM CH COONH CH CN (70:0) Flow rate: 0.ml/min Column temperature: 0 C Detector: UV, 0nm and ESI-MS (-ve SIM) For free technical advice and support technical@hichrom.co.uk Mins Figure. LC-MS of barbital in BSA Ordering Information - ODP HP Product Particle Size (µm) Column Dimensions (mm) Catalogue No. Price ODP HP-B 5 50 x.6 F ODP HP-D 5 50 x.6 F ODP HP-E 5 50 x.6 F ODP HPG-A 5 0 x.6 (guard column, /pk) F6700 ODP HP-GC 5 0 x.0 (guard cartridge, /pk) F ODP HP-B 5 50 x.0 F ODP HP-D 5 50 x.0 F ODP HPG-A 5 0 x.0 (guard column, /pk) F670 Use with guard cartridge holder HLD-GC (Cat. No. F870000, 0) Mins Reversed-Phase (Silica-based) Phases Please enquire for details of reversed-phase silica-based columns, including Silica NPE (nitrophenylethyl) and Silica PYE (pyrenylethyl). 0

3 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk Columns for Saccharide Analysis Ligand Exchange Phases ( SUGAR Series) SUGAR SH Styrene-divinylbenzene Sulpho (H + ) Separation of saccharides by ligand exchange, SUGAR SC Styrene-divinylbenzene Sulpho (Ca + ) size exclusion, ion exclusion and normal-phase. SUGAR SP Styrene-divinylbenzene Sulpho (Pb + ) Suitable for separation of sugars and sugar alcohols SUGAR SZ Styrene-divinylbenzene Sulpho (Zn + ) SUGAR KS Styrene-divinylbenzene Sulpho (Na + ) Separation of saccharides by size exclusion and ligand exchange USPpak MN Styrene-divinylbenzene Sulpho (Ca + ) Analysis of mannitol by USP method There are two series of columns for saccharide analysis the SUGAR series for operation in ligand exchange mode and Asahipak NHP-50 polymeric amino columns for normal-phase and HILIC modes. A. SUGAR Series The SUGAR series columns are based on polystyrene-divinylbenzene copolymer with strong cation-exchange resin incorporating functional sulpho groups coupled with metal counter ions (H +, Ca +, Pb +, Zn +, Na + ). B. Asahipak NHP Asahipak NHP is an amino bonded column in which polyamine is bonded to a hydrophilic polyvinyl alcohol polymer. The high separation power of conventional silica-based columns is maintained, whilst showing an increased usable ph range ( ) and increased robustness. Figure illustrates the reproducibility over time obtained from the polymeric Asahipak NHP column.. Fructose. Glucose. Sucrose. Maltose 80 h Column: Asahipak NHP-50 E (50 x.6mm) Eluent: CH CN H O (75:5) Flow rate:.0ml/min Column temperature: 0 C Detection: RI Figure. Reproducibility with Asahipak NHP Mins Mins Ordering Information - Columns for Saccharide Analysis Product Counter Separation Exclusion Limit Particle Size Column Dimensions Ion Mode (Da) (µm) (mm) Catalogue No. Price SUGAR SH0 H + SEC + IEX, x 8.0 F SUGAR SH8 H + SEC + IEX 0, x 8.0 F SUGAR SH-G H + - Guard column 0 50 x 6.0 F SUGAR SC0 Ca + SEC + LEX, x 8.0 F SUGAR EP SC0-7F Ca + SEC + LEX, x 7.8 F SUGAR SC8 Ca + SEC + LEX 0, x 8.0 F SUGAR SC-LG Ca + - Guard column 0 50 x 6.0 F SUGAR SP080 Pb + SEC + LEX, x 8.0 F SUGAR SP-G Pb + - Guard column 0 50 x 6.0 F SUGAR SC Ca + NP + LEX x 6.0 F SUGAR SC-G Ca + - Guard column 0 0 x.6 F SUGAR SZ55 Zn + NP + LEX x 6.0 F SUGAR SZ-G Zn + - Guard column 6 0 x.6 F SUGAR KS-80 Na + SEC + LEX, x 8.0 F SUGAR KS-80 Na + SEC + LEX 0, x 8.0 F SUGAR KS-80 Na + SEC 50, x 8.0 F SUGAR KS-80 Na + SEC 00, x 8.0 F SUGAR KS-805 Na + SEC 5,000, x 8.0 F SUGAR KS-806 Na + SEC 50,000, x 8.0 F SUGAR KS-G Na + - Guard column 0 50 x 6.0 F SUGAR KS-807 Na + SEC 00,000, x 8.0 F678070,6 SUGAR KS-807G Na + - Guard column 0 50 x 8.0 F67000 USPpak MN- Ca + LEX x.0 F Asahipak Phases NHP-0 E - NP/HILIC - 50 x.0 F NHP-50G A - - Guard column 5 0 x.0 F NHP-50 D - NP/HILIC x.6 F NHP-50 E - NP/HILIC x.6 F NHP-50G A - - Guard column 5 0 x.6 F NHP-50 D - NP/HILIC x.0 F NHP-50G A - - Guard column 5 0 x.0 F NHP-LF - - Line filter - 75 x 8.0 F Preparative columns also available Hichrom Limited sales@hichrom.co.uk Tel:

4 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk Ion-Exchange Phases Ion-Exchange Phases IEC QA Polyhydroxymethacrylate Quaternary ammonium Strong anion-exchange IEC DEAE Polyhydroxymethacrylate Diethylaminoethyl Weak anion-exchange Suitable for analysis of proteins, peptides, DNA, IEC SP Polyhydroxymethacrylate Sulphopropyl Strong cation-exchange RNA, oligonucleotides IEC CM Polyhydroxymethacrylate Carboxymethyl Weak cation-exchange Asahipak ES-50N Polyvinyl alcohol Diethylaminoethyl Weak anion-exchange Asahipak ES-50C Polyvinyl alcohol Carboxymethyl Weak cation-exchange AXpak WA Polyhydroxymethacrylate Diethylaminoethyl Weak anion-exchange, suitable for analysis of nucleic acids CXpak P Styrene-divinylbenzene Sulpho (Na + ) Analysis of amino acids and amino sugars PIKESS DEAE Polyhydroxymethacrylate Diethylaminoethyl Weak anion-exchange UHPLC compatible PIKESS SP Polyhydroxymethacrylate Sulphopropyl Strong cation-exchange (.5µm material) The IEC series (QA and DEAE anion-exchange phases and SP and CM cation-exchange phases) is based on polyhydroxymethacrylate. Columns are suitable for the analysis of relatively high molecular weight compounds, such as proteins. The newer PIKESS materials are non-porous.5µm particles, suitable for rapid protein analyses using UHPLC systems (see Figure ).. Myoglobin. Trypsinogen. Ribonuclease A. a-chymotrypsinogen A 5. Cytochrome C 6. Lysozyme 5 6 Column: PIKESS SP-B (50 x.0mm) Eluent: A: 0mM Na phosphate, ph 7.0 B: A + 0.5M NaCl Linear gradient, 00% A to 50% A in.5min Flow rate:.ml/min Detection: UV, 80nm 5µ S/cm Column: IC YS-50 (5 x.6mm) Eluent: mm methanesulphonic acid Flow rate:.0ml/min Column temperature: 0 C Detector: Non-suppressed conductivity 5 6. Li + ppm. Na + 0ppm. NH + 0ppm. K + 0ppm 5. Mg + 0ppm 6. Ca + 0ppm Mins Figure. Rapid analysis of proteins using UHPLC and ion-exchange Mins Figure. Separation of cations using ion chromatography Please enquire for ordering details of ion-exchange columns. Ion Chromatography Phases Ion Chromatography Phases IC NI, I Polyhydroxymethacrylate Quaternary ammonium Anion analysis with non-suppressed detection IC SI Polyvinyl alcohol Quaternary ammonium Anion analysis with suppressed detection Cations by non-suppressed detection. Y for alkylamines. IC Y, T, R Styrene-divinylbenzene Sulpho T for transition metals and R for rare earth metals by post-column reaction IC YK Silica Carboxyl Monovalent and divalent cations by non-suppressed detection IC YS Silica Carboxyl Higher performance version of YK For free technical advice and support technical@hichrom.co.uk A range of columns are available for both non-suppressed and suppressed ion chromatography. Columns are also supplied for analysing transition metal ions and rare earth metal ions using post-column reactions. Figure shows the separation of six common cations on a IC YS-50 column with non-suppressed conductivity detection. Ordering Information - Columns for Ion Chromatography Column Particle Size (µm) Column Dimensions (mm) Catalogue No. Price Guard Column Catalogue No. Price IC NI x.6 F IC NI-G F IC I-5A 00 x.6 F IC IA-G F IC Y-5 50 x.6 F IC Y-G F IC YK- 5 5 x.6 F IC YK-G F IC YS x.6 F7000,06 IC YS-G F IC SI-90 E 9 50 x.0 F IC SI-90G F IC SI-50 E 5 50 x.0 F IC SI-50G F IC T-5 50 x.6 F IC T-G F6700 IC R x 6.0 F IC R-G F PEEK hardware

5 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GFC Phases Aqueous SEC (GFC) Phases PROTEIN KW Silica Hydrophilic polymer OHpak SB Polyhydroxymethacrylate - Analysis of high MW biological fluids. Suitable for separating proteins of MW few thousand to few million Da Analysis of water-soluble samples and for molecular weight distribution PROTEIN KW-800 and KW00 are silica based series with high protein recovery rates. Whereas the KW-800 columns have the highest sample loading, the reduced particle size of KW00 columns enable - times greater sensitivity. Figure 5 illustrates the enhanced sensitivity achieved for a range of proteins with a KW00 column.. Blue dextran mg/ml. g-globulin 0.8mg/ml. Ovalbumin 0.8mg/ml. Myoglobin 0.56mg/ml 5. Uridine 0.0mg/ml 5 Columns: (A) KW0.5-F (00 x.6mm) (B) PROTEIN KW-80.5 (00 x 8mm) Eluent: 50mM Na phosphate buffer, ph M NaCl Flow rate: (A) 0.ml/min (B).0ml/min Detector: UV, 80nm Sample volume: 0µl (A) KW0.5-F (B) KW Mins Mins 5 Figure 5. Comparison between KW00 and KW-800 columns The OHpak SB-800 and SB00 series are based on polyhydroxymethacrylate and are used for the analysis of a wide range of molecular weight compounds. Ordering Information GFC Columns PROTEIN Particle Size Pore Size (Å) Exclusion Limit (Da) Column Dimensions Catalogue Product (µm) Average Maximum Pullulan Protein (mm) No. Price KW ,000 50, x 8.0 F KW ,000 70, , x 8.0 F KW , ,000,000, x 8.0 F KW-G 7 Guard column 50 x 6.0 F KW0.5-F ,000 50, x.6 F KW0-F , , x.6 F KW0-F 5 500, ,000,000, x.6 F KW05-F 5 700,000,00,000 0,000, x.6 F KW00G-A 5 Guard column 0 x.6 F OHpak Product Particle Size (µm) Pore Size (Å) (Maximum) Exclusion Limit (Da) Pullulan Column Dimensions (mm) Catalogue No. SB-80 HQ 8 00, x 8.0 F SB-80.5 HQ , x 8.0 F SB-80 HQ , x 8.0 F SB-80 HQ 0,000,000, x 8.0 F SB-805 HQ 7,000,000, x 8.0 F SB-806 HQ 5,000 0,000, x 8.0 F SB-806M HQ 5,000 0,000, x 8.0 F SB-G 0 Guard column 50 x 6.0 F SB-807 HQ 5 0, ,000, x 8.0 F6908,79 SB-807G 5 Guard column 50 x 8.0 F SB0-E 0 0, x.6 F SB0.5-E , x.6 F SB0-E , x.6 F SB0-E 7,000,000, x.6 F SB00G-A 7 Guard column 0 x.6 F Price Hichrom Limited sales@hichrom.co.uk Tel:

6 Other Phases Aqueous/Organic SEC Phases Asahipak GF Polyvinyl alcohol None Both water and organic solvents can be used. Suitable for samples with both hydrophilic and hydrophobic moieties. The Asahipak GF Series columns are based on polyvinyl alcohol and can be used with both aqueous and organic solvents. Please enquire for further details and ordering information for aqueous/organic SEC phases. Organic SEC (GPC) Phases GPC KF, K, KD, HFIP, LF, HT, UT, AT Styrene-divinylbenzene None KF-800 series shipped in THF. K-800 series shipped in CHCl. KD-800 series shipped in DMF suitable for assay of polar polymers. HFIP suitable for engineering plastics eg. PET, polyamides. HT, UT and AT series for higher temperature GPC. Please enquire for further details and ordering information for organic SEC (GPC) phases. Hydrophobic Interaction Phase HIC PH Polyhydroxymethacrylate Phenyl Analysis of proteins The HIC PH-8 column separates proteins without denaturation. It is applicable to samples after treatment of ammonium sulphate fractions. Organic Acids Phase RSpak KC Styrene-divinylbenzene Sulpho Analysis of organic acids by ion exclusion and reversed-phase modes RSpak KC columns are suitable for the analysis of organic acids by ion exclusion and reversed-phase modes. Affinity Phases AFpak 6 kinds Polyhydroxymethacrylate 6 kinds of ligand Purification of biological molecules depending on biochemical affinity The AFpak range of affinity columns consists of 6 different ligand materials, designed for specific applications. Chiral Separation Phases ORpak CDA, CDB, CDC Polyhydroxymethacrylate Cyclodextrin derivative Suitable for separation of optical isomers and structural isomers. CDA is a-cd, CDB is b-cd, CDC is g-cd ORpak CDBS Silica Cyclodextrin derivative CDBS is b-cd ORpak CRX Polyhydroxymethacrylate L-amino acid derivative Separation of amino acids by ligand exchange For free technical advice and support technical@hichrom.co.uk ORpak CD phases consist of a-, b- or g-cyclodextrin bonded to polyhydroxymethacrylate base material or silica (a-cyclodextrin). ORpak CRX columns have an L-amino acid derivative bonded to polyhydroxymethacrylate and are suitable for the separation of optical isomers of amino acids and hydroxy acids. Please contact Hichrom for further information on any column and for ordering information for columns not listed.

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

SHODEX. by Showa Denko K.K.

SHODEX. by Showa Denko K.K. selectosil For Availability and Ordering nformation please contact your Phenomenex Technical Consultant. SHODEX Selectosil/ High efficiency polymer columns Excellent mechanical and chemical stability Wide

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Saccharides and Organic Acids

Saccharides and Organic Acids Saccharides and Organic Acids Contents Introduction... 2 Reducing Sugars... 2 HILIC The HILICpak and Ashipak Series... 3 Shodex HILIC Columns for Sugar Analysis... 7 Ligand Exchange Shodex SUGAR series...

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9. HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Extraction - SOLA & HyperSep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Phase Extraction - Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660 Fax: +44

More information

HPLC Columns. Capture the Essence SHOWA DENKO K.K.

HPLC Columns. Capture the Essence SHOWA DENKO K.K. HPLC Columns 0 0 Capture the Essence SHOWA DENKO K.K. TM We provide a wide range of products to meet your analytical needs, from pretreatment and separation columns to calibration standards for size exclusion

More information

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS CHAPTER 25: Opener Aa CHAPTER 25: Opener Ab CHAPTER 25: Opener B 25-1 Ion-Exchange

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Thermo Scientific Acclaim Catalogue The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0) 0 0 Fax: + (0) Email: sales@hichrom.co.uk

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

HPLC Columns SHOWA DENKO K.K. Capture the Essence.

HPLC Columns SHOWA DENKO K.K. Capture the Essence. HPLC Columns 0 0 Capture the Essence SHOWA DENKO K.K. US: 09 Miratech Drive, Suite 00, San Diego, California 9 E. info@amuzainc.com P..0. F..0.00 TM We provide a wide range of products to meet your analytical

More information

Protein & peptide Shodex TM columns

Protein & peptide Shodex TM columns HPLC Columns Protein & peptide Shodex TM columns Technical notebook No. 7 Contents. Introduction. Separation of Proteins and Peptides by HPLC. Separation modes -. Size exclusion chromatography --. Separation

More information

Liquid Chromatography

Liquid Chromatography Liquid Chromatography 1. Introduction and Column Packing Material 2. Retention Mechanisms in Liquid Chromatography 3. Method Development 4. Column Preparation 5. General Instrumental aspects 6. Detectors

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Inertsil Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin Ion Exchange Chromatography Chromatographic Process BA Mobile phase Stationary Phase A Shula Levin Bioforum B Distribution: K = C s/c m B shulal@zahav.net.il http://shulalc.co.il/ A Elution through the

More information

HPLC Columns. Capture the Essence

HPLC Columns. Capture the Essence HPLC Columns Capture the Essence 0-09 We provide a wide range of products to meet your analytical needs, from pretreatment and separation columns to calibration standards for size exclusion chromatography.

More information

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How? Jean Lane Applications Engineer LC Columns & Consumables Technical Support January 19, 2017 What we will cover What - Clarification of the

More information

Sample Preparation TLC Plates

Sample Preparation TLC Plates TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,

More information

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science HPLC Column Selection: Solve the Separation Mystery The world leader in serving science verview Introduction Historical verview in Stationary Phases Basics in Column Selection Resolution, Efficiency and

More information

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography Sepax Technologies, Inc. Preparative Size Exclusion Chromatography SRT -0/0C (0 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC Better Surface Chemistry for Better Separation SRT -0/0C Size Exclusion

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Optical Isomer Separation Columns and Packing Materials

Optical Isomer Separation Columns and Packing Materials 02 Optical Isomer Separation s and Packing Materials CHIRAL ART----------------------------------- 26~29 YMC CHIRAL NEA (R), (S)-----------------------30 YMC CHIRAL CD BR------------------------------31

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

LIQUID CHROMATOGRAPHY

LIQUID CHROMATOGRAPHY LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid

More information

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY

ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY CHROMATOGRAPHY Week 9-10 Reading Assignment: Chapter 7. Bioseparations Science & Engineering, Harrison, R; Todd, P; Rudge, S.C and Petrides, D,P CHROMATOGRAPHY

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Chromatographic Methods: Basics, Advanced HPLC Methods

Chromatographic Methods: Basics, Advanced HPLC Methods Chromatographic Methods: Basics, Advanced HPLC Methods Hendrik Küpper, Advanced Course on Bioinorganic Chemistry & Biophysics of Plants, summer semester 2018 Chromatography: Basics Chromatography a physical

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

Guide to Choosing and Using Polymer Reversed Phase Columns!

Guide to Choosing and Using Polymer Reversed Phase Columns! Guide to Choosing and Using Polymer Reversed Phase Columns! Choosing the best RP Column to use: Silica is normally used as the packing material for HPLC columns for a number of reasons. It is very strong,

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia HPLC Columns MANUAL HILICpak VT-50 2D Shodex HPLC Columns Europe, Middle East, Africa, Russia For technical support please use contact details shown below: SHOWA DENKO EUROPE GmbH Shodex Business Konrad-Zuse-Platz

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet 2-1, Otemachi 2-Chome Chiyoda-ku, Tokyo 100-8105 JAPAN Phone +81-3-3243-6150 Fax +81-3-3243-6219 e-mail:

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

Cellufine Butyl Cellufine Phenyl

Cellufine Butyl Cellufine Phenyl Hydrophobic Interaction Chromatography Media Cellufine Butyl Cellufine Phenyl Technical Data Sheet Introduction For purification of proteins and macromolecules Hydrophobic Interaction Chromatography (HIC)

More information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analysis - HPLC A.136. Primesep 5 µm columns B.136 Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using

More information

TSKgel SW TSKgel SW XL TSKgel SuperSW. TSKgel PW TSKgel PW XL -CP. TSKgel Alpha TSKgel SuperAW. TSKgel H XL TSKgel H HR TSKgel Super H TSKgel Super HZ

TSKgel SW TSKgel SW XL TSKgel SuperSW. TSKgel PW TSKgel PW XL -CP. TSKgel Alpha TSKgel SuperAW. TSKgel H XL TSKgel H HR TSKgel Super H TSKgel Super HZ 8 www.tosohbioscience.com size exclusion CHROMATOGRAPHY Tosoh bioscience ANALYSIS sec size exclusion chromatography 9 size exclusion CHROMATOGRAPHY PRODUCTS TSK-GEL SW-type TSKgel SW TSKgel SW XL TSKgel

More information

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania ESSENTIALS IN MODERN HPLC SEPARATIONS Serban C. Moldoveanu1, Victor David2 'R.J. Reynolds Tobacco Co., Winston-Salem, NC, USA 2University of Bucharest, Bucharest, Romania ELSEVIER AMSTERDAM BOSTON HEIDELBERG

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents No.038 GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series Contents Page 1. Introduction 2. Calibration curves, theoretical plate numbers and separation range

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

Protein chromatography

Protein chromatography Protein chromatography Ion exchange chromatography Affinity chromatography Marc Baumann Institute of Biomedicine, University of Helsinki, 2012 Chromatography Separation of biomolecules is based on their

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS 1. List two advantages of temperature programming in GC. a) Allows separation of solutes with widely varying retention factors in a reasonable

More information

TSKgel Size Exclusion Chromatography Columns

TSKgel Size Exclusion Chromatography Columns Silica-based for protein analysis: TSKgel SW mab TSKgel SW TSKgel SWXL TSKgel SuperSW Polymer-based for desalting: TSKgel BioAssist DS Columns Polymethacrylate-based for water-soluble polymers analysis:

More information

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents GPC-/SEC-Columns & 2 accessories2 0 18 direct from Producer packed in new generation column hardware! MZ-Gel SD MZ-Gel SD LS MZ-Super FG Development Manufacturing Distribution Consulting HPLC-Columns New

More information

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver SPE Simply Efficient! Watchers bond Solid Phase Extraction by ISU Ver. 05-11 Solid Phase Extraction Basic principles of Solid Phase Extraction Solid phase extraction (SPE) is a powerful method for sample

More information

Reversed Phase Columns. SEC Columns. Ion Exchange Columns. Application Specific Columns. Guard Columns. HILIC Columns. Normal Phase Columns.

Reversed Phase Columns. SEC Columns. Ion Exchange Columns. Application Specific Columns. Guard Columns. HILIC Columns. Normal Phase Columns. C o n t e n t s Column Selection Overview Ex Reversed-Phase Column Selection Guide Ex5 Selectivity Comparison of Reversed-Phase Ex7 Normal-Phase Column Selection Guide Ex0 Column Specifications...Ex Conforming

More information

Chromatography. writing in color

Chromatography. writing in color Chromatography writing in color Outlines of Lecture Chromatographic analysis» Principles and theory.» Definition.» Mechanism.» Types of chromatography.» Uses of Chromatography. In 1906 Mikhail Tswett used

More information

Anion Exchange HPLC Columns

Anion Exchange HPLC Columns Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride

More information

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor luorophenyl Column With Raptor

More information

GPC/SEC An essential tool for polymer analysis

GPC/SEC An essential tool for polymer analysis GPC/SEC An essential tool for polymer analysis Ben MacCreath, PhD Product Manager GPC/SEC Instrumentation 26 th March 2013 Introduction to Polymers Where are they found? Polyolefins Engineering Polymers

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific Thermo Scientific Acclaim Trinity P2 Column Product Manual P/N: October 2013 Part of Thermo Fisher Scientific Product Manual for Acclaim Trinity P2 Columns Acclaim Trinity P2, 3µm, Analytical Column, 3.0

More information

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.bgb-shop.com/raptor The Raptor luorophenyl Column With

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE Introduction Gel permeation chromatography (GPC) and size exclusion chromatography

More information

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page No.106 Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series Contents Page 1. Introduction 2. Features 3. Basic characteristics 3-1. Pore characteristics 3-2. Sample injection volume

More information

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

HPLC Winter Webinars Part 2: Sample Preparation for HPLC HPLC Winter Webinars Part 2: Sample Preparation for HPLC Jon Bardsley, Application Chemist Thermo Fisher Scientific, Runcorn/UK The world leader in serving science What am I Going to Talk About? What do

More information

6 Optical Isomer Separation Columns

6 Optical Isomer Separation Columns YMC GENERAL CATALG ptical Isomer Separation Columns YMC CHIRAL CD BR series YMC CHIRAL NEA YMC CHIRAL PREP CD ST/PM 128,129 13,131 132,133 127 第 章.indd 127 11.1.28 1:57:24 AM ptical isomer structural isomer

More information

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies Gel Permeation Chromatography Basics and Beyond eseminar March 13, 2013 Jean Lane Technical and Applications Support LSCA, Columns and Supplies 1 Content Overview of GPC/SEC What is it? Why do we use it?

More information

Monitoring Protein PEGylation with Ion Exchange Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography Monitoring Protein PEGylation with Ion Exchange Chromatography Peter Yu, Deanna Hurum, Leo Wang, Terry Zhang, and Jeffrey Rohrer 245 th ACS National Meeting & Exposition April 9, 213 OT7618_E 4/13S 1 The

More information

Column Selection for Size Exclusion Chromatography (SEC)

Column Selection for Size Exclusion Chromatography (SEC) Column Selection for Size Exclusion Chromatography (SEC) Application Solvent Column Page Biological macromolecules (proteins, peptides, nucleic acids, etc.) Buffer etc. KW-800 series KW400 series High

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Chapter 2 The Chemistry of Biology. Dr. Ramos BIO 370

Chapter 2 The Chemistry of Biology. Dr. Ramos BIO 370 Chapter 2 The Chemistry of Biology Dr. Ramos BIO 370 2 Atoms, Bonds, and Molecules Matter - all materials that occupy space and have mass Matter is composed of atoms. Atom simplest form of matter not divisible

More information

NOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution

NOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution Having trouble applying size exclusion chromatography to peptides under 1, Da? What if there was a size exclusion column specifically designed for small protein and peptide separations? Sepax Zenix SEC-8

More information

1. Ion exchange chromatography

1. Ion exchange chromatography 1. Ion exchange chromatography Ion Exchange Chromatography Most popular method for the separation or purification of charged molecules. In cation exchange chromatography, positively charged molecules are

More information

Optimizing GPC Separations

Optimizing GPC Separations Optimizing GPC Separations Criteria for Solvent Selection True sample solubility (Polarity and Time dependant) Compatibility with columns Avoid non-size exclusion effects (eg adsorption by reverse phase

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

Acclaim Mixed-Mode WAX-1 Columns

Acclaim Mixed-Mode WAX-1 Columns User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,

More information

Protein separation and characterization

Protein separation and characterization Address:800 S Wineville Avenue, Ontario, CA 91761,USA Website:www.aladdin-e.com Email USA: tech@aladdin-e.com Email EU: eutech@aladdin-e.com Email Asia Pacific: cntech@aladdin-e.com Protein separation

More information

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent

More information

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity Janet Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS High

More information

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference GPC/SEC Practical Tips and Tricks Thomas Dent Applications Scientist Agilent Technologies October, 2011 Gulf Coast Conference 1 Section 1: Introduction Goals Brief introduction to GPC/SEC Highlight considerations

More information

Chapter content. Reference

Chapter content. Reference Chapter 7 HPLC Instrumental Analysis Rezaul Karim Environmental Science and Technology Jessore University of Science and Technology Chapter content Liquid Chromatography (LC); Scope; Principles Instrumentation;

More information

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography LC III: HPLC What is HPLC? Originally referred to as High-Pressure Liquid Chromatography Now more commonly called High Performance Liquid Chromatography In general: The instrument controlled version of

More information

excellent performance spherical and sharp particle size distribution persistence and highest quality

excellent performance spherical and sharp particle size distribution persistence and highest quality ISO 00 Certified Working to enhance quality management excellent performance spherical and sharp particle size distribution persistence and highest quality offeres packing materials and packed, under strict

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information