columns IonPac AS22 Anion-Exchange Column

Size: px
Start display at page:

Download "columns IonPac AS22 Anion-Exchange Column"

Transcription

1 columns IonPac AS Anion-Exchange Column The IonPac AS is a carbonate based anion-exchange column designed for the determination of inorganic anions and low-molecular-weight organic acids including fluoride, acetate, chloride, nitrite, bromide, nitrate, phosphate, and sulfate. The AS column is used with isocratic carbonate/bicarbonate eluents and suppressed conductivity detection. The AS column can be used in combination with Dionex Eluent Generators and the Electrolytic ph Modifier (EPM), which automatically produce potassium carbonate/bicarbonate eluents from water. The IonPac AS-Fast column is ideal for fast IC using eluent generation or eluent regeneration. Column Performance The IonPac AS column meets the performance requirements specfied in U.S. Environmental Protection Agency (EPA) Method 00.0 (A). The common inorganic anions are easily separated in a variety of sample matrices, including drinking water, wastewater, process streams, and scrubber solutions. The AS selectivity provides excellent retention of fluoride from the water dip and resolution of fluoride, acetate, and formate. Solvent compatibility permits easy column cleanup after the analysis of samples with hydrophobic components. Fast IC The IonPac AS-Fast is ideal for Fast IC as it is designed to have sufficient capacity to maintain resolution even in a short column format. Fast separations are achieved on any Dionex system at higher flow rates. In a short column format, backpressures produced at higher flow rates are reduced while allowing overall shorter run times. This allows for the determination of anions with high resolution even in drinking, surface, groundwater, and wastewater matrices in under min. Laboratories can achieve higher productivity and increased throughput. Passion. Power. Productivity.

2 Analyze Inorganic Anions in Diverse Sample Matrices Source water and drinking water Municipal and industrial wastewater Industrial cooling water Hazardous waste extracts and dump site leachates Acid rain Foods and beverages Anionic counterions in pharmaceutical preparations and synthetic peptides Polymers such as polyols and polysulfonates Scrubber solutions Superior Chromatographic Performance Fast isocratic separation of the common inorganic anions in simple sample matrices in 8 min. Isocratic separation of common inorganic anions in complex sample matrices in min. High speed separation of the common inorganic anions in less than min using the AS-Fast Column. Carbonate peak well resolved from common inorganic anions. Meets performance requirements specified in EPA Method 00.0 (A). Ideal alternative for IonPac ASA- SC, ASA, AS, and ASA inorganic anion applications. Simplified Reagent-Free ion chromatography (RFIC ) System operation provided by Dionex Eluent Generators and EPM, which require only a deionized water source to produce potassium carbonate/bicarbonate eluent. Ideal column for use with Dionex Eluent Regeneration, enabling simple, non-stop operation for up to 8 days. Simple, accurate eluent preparation with the AS Eluent Concentrate just dilute in deionized water and start operation. Eluent suppression using the ASRS 00 or AAES technology provides Reagent-Free IC operation with low backgrounds and enhanced analyte sensitivity. Conceptual Illustration of Surface Modification Figure. Structure of an IonPac AS column particle. Column: IonPac AG, AS, mm Eluent:. mm sodium carbonate/. mm sodium bicarbonate Temperature: 0 C Flow Rate:. ml/min Inj. Volume: 0 µl Detection: Suppressed conductivity, ASRS 00, mm, Figure. Separation of common inorganic anions plus acetate on an IonPac AS column using a. mm carbonate/. mm bicarbonate eluent. High capacity: 0 µeq/col. ( 0 mm column). Operate at ambient or elevated temperatures. Column selectivity is optimized for a 0 C operating temperature to ensure reproducible retention times. Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or for effective column cleanup. Peaks:. Fluoride mg/l (ppm). Acetate 0. Chloride 0. Nitrite. Bromide. Nitrate. Phosphate 0 8. Sulfate

3 High Efficiency Particle Structure The IonPac AS column was developed using a unique polymer bonding technology. The stationary phase consists of a novel hyper-branched anion-exchange condensation polymer, electrostatically attached to the surface of a wide-pore polymeric substrate. The substrate is surface-sulfonated in exactly the same manner as is common in Dionex latex coated anion-exchange materials. However, in this anionexchange resin, alternating treatments of epoxy monomer and amines produce a coating which is grown directly off the substrate surface as illustrated in Figure. Resin capacity is controlled through the number of alternating coating cycles. The AS mm uses a high-capacity resin (0 µeq/column) with optimized selectivity for the common inorganic anions in a variety of sample matrices. Isocratic Separation of Common Inorganic Anions The AS provides excellent separation of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate using an isocratic carbonate/bicarbonate eluent and suppressed conductivity detection. Using a. mm carbonate/. mm bicarbonate eluent, the common inorganic anions plus acetate can be resolved in approximately min as shown in Figure. Column: IonPac AG, AS, mm Peaks:. Fluoride 0.8 mg/l (ppm). Bromide 0.0 Eluent:. mm sodium carbonate/. Formate Nitrate mm sodium bicarbonate. Chloride.9 9. Carbonate NQ Temperature: 0 C. Nitrite Phosphate 0. Flow Rate:. ml/min. Unknown NQ. Sulfate 0. Inj. Volume: µl. Chlorate 0.8 Detection: Suppressed conductivity, ASRS 00, mm, NQ: Not Quantified Figure. Determination of inorganic anions in a municipal drinking water sample on an IonPac AS column Inorganic Anions in Drinking Water The IonPac AS is ideal for compliance monitoring of drinking water and wastewater. The column meets or exceeds the performance requirements of U.S EPA Method 00.0 (A). Common inorganic anions are separated in approximately min in drinking water as shown in Figure.

4 Fast IC The IonPac AS-Fast column is suitable for separations requiring higher flow rates for the fast analysis of inorganic anions in simple sample matrices as shown in Figure. The IonPac AS- Fast column ( 0 mm) was operated with the same eluent at. and.0 ml/min. Using a higher flow rate in a shorter column format, the overall run time was reduced to. min with optimal resolution of the common inorganic anions. The use of an AS-Fast 0 mm column format allows greater linear velocities and reduced eluent consumption compared to a mm format. Figure shows the excellent resolution for the common inorganic anions in less than min. Column: IonPac AS-Fast ( 0 mm) Eluent:. mm sodium carbonate. mm sodium bicarbonate Flow Rate: A.. ml/min B..0 ml/min Inj. Volume: 0 µl Temperature: 0 C Detection:.0.0. A B Suppressed conductivity, ASRS 00, mm, Peaks:. Fluoride.0 mg/l (ppm). Chloride 0.0. Nitrite.0. Bromide.0. Nitrate.0. Phosphate 0.0. Sulfate Figure. Separation of common inorganic anions using the IonPac AS-Fast 0 mm column. Column: IonPac AS-Fast ( 0 mm) Eluent:. mm sodium carbonate. mm Sodium bicarbonate Flow Rate: A. 0. ml/min B. 0. ml/min C. 0. ml/min Inj. Volume:. µl Temperature: 0 C Detection: Suppressed conductivity, ASRS 00, mm, A) Peaks:. Fluoride.0 mg/l (ppm). Chloride 0.0. Nitrite.0. Bromide.0. Nitrate.0. Phosphate 0.0. Sulfate B) C) Figure. Separation of common inorganic anions using the IonPac AS-Fast 0 mm column.

5 Figure illustrates the analysis of a municipal drinking water sample using the AS-Fast ( 0 mm). At.0 ml/min, the anions can be separated in less than min. The bottom trace shows an enlarged image of the separation. The anions are well resolved even in the presence of disparate anion concentrations including fluoride/formate and chloride/nitrite. Extended Application Capabilities The unique selectivity and high capacity of the AS column makes it ideal for methods development of specialized anion applications. Figure shows the separation of a variety of environmental anions including inorganic anions, oxyhalides, oxyanions, and organic acids using an isocratic carbonate/bicarbonate eluent. These 8 analytes are easily separated in less than 0 min. Column: IonPac AS-Fast ( 0 mm) Eluent:. mm sodium carbonate. mm sodium bicarbonate Flow Rate:.0 ml/min Inj. Volume: 00 µl Temperature: 0 C Detection: Suppressed conductivity, ASRS 00, mm, Peaks:. Fluoride. Bromide. Formate. Nitrate. Chloride 8. Carbonate. Nitrite 9. Phosphate. Chlorate 0. Sulfate Figure. Analysis of a municipal drinking water sample using the IonPac AS-Fast 0 mm column. S Column: IonPac AG, AS, mm Eluent:.8 mm sodium carbonate/.0 mm sodium bicarbonate Flow Rate:. ml/min Temperature: 0 C Inj. Volume: 0 µl Detection: Suppressed conductivity, ASRS 00, mm, Peaks:. Fluoride mg/l (ppm). Acetate 0. Formate 0. Bromate 0. Chloride. Nitrite. Chlorate 8. Bromide 9. Nitrate 0. Phosphate 0. Sulfate 0. Selenate 0. Iodide 0. Arsenate 0. Thiocyanate 0. Perchlorate 0. Thiosulfate 0 8. Chromate Figure. Anion separation including inorganic anions, organic acids, oxyanions, and oxyhalides on an IonPac AS column.

6 The IonPac AS column is also ideal for the determination of anions in food and beverage samples containing high concentrations of carbonate. Carbonated bottled water contains up to 00 mg/l (ppm) of carbonate. The unique selectivity of the AS column positions carbonate well away from the common inorganic anions and does not interfere with quantification of the analytes of interest. Figure 8 shows the determination of inorganic anions in carbonated water using the AS column. The AS column can be used to evaluate the mass balance of drugs and synthetic peptide preparations. Figure 9 illustrates the use of the AS column to determine the anionic counterion amount and type. The common inorganic anions plus trifluoroacetate can be determined in less than min Column: IonPac AG, AS, mm Eluent:. mm sodium carbonate/. mm sodium bicarbonate Temperature: 0 C Flow Rate:. ml/min Inj. Volume: 0 µl Detection: Suppressed conductivity, ASRS 00, mm, 0.0 Peaks:. Fluoride 0.9 mg/l (ppm). Chloride.8. Bromide 0.9. Nitrate.. Carbonate NQ. Phosphate 0.. Sulfate. NQ: Not Quantified Figure 8. Determination of inorganic anions in carbonated water on an IonPac AS column. Column: IonPac AG, AS, mm Eluent:. mm sodium carbonate/. mm sodium bicarbonate Temperature: 0 C Flow Rate:. ml/min Inj. Volume: 0 µl Detection: Suppressed conductivity, ASRS 00, mm, Peaks:. Fluoride mg/l (ppm). Acetate 0. Chloride. Trifluoroacetate 0. Bromide 0. Nitrate 0. Phosphate 0 8. Sulfate Figure 9. Analysis of the common inorganic anions and TFA using the IonPac AS column.

7 SPECIFICATIONS Dimensions: IonPac AS Analytical Column: 0 mm, 0 mm IonPac AS-Fast Analytical Column: 0 mm, 0 mm IonPac AG Guard Column: 0 mm, 0 mm IonPac AG-Fast Guard Column: 0 mm, 0 mm Maximum Operating Pressure: 000 psi Mobile Phase Compatibility: ph 0 ; 0 00% HPLC solvents Substrate Characteristics: Analytical Column: Supermacroporous resin Bead Diameter (µm):. µm Pore Size: 000 Å Crosslinking (%DVB): % Guard Column: Microporous resin Bead Diameter (µm): µm Pore Size: < Å Crosslinking (%DVB): % Ion-Exchange Group: Functional Group: Alkanol quaternary ammonium ion Functional Group Characteristics: Hydrophobicity: Ultralow hydrophobic Capacity:. µeq ( 0 mm column). µeq ( 0 mm column) 0 µeq ( 0 mm column) µeq ( 0 mm column) µeq ( 0 mm column).0 µeq ( 0 mm column). µeq ( 0 mm column).0 µeq ( 0 mm column) Column Construction: PEEK with 0 threaded ferrule style end fittings. All components are nonmetallic. ORDERING INFORMATION System Requirements for EGC-K CO /KHCO Eluent Generation For K CO /KHCO eluents generated using the EGC-K CO cartridge and the EPM, use with ICS-00 or ICS-000 IC systems equipped with an Eluent Generator. The Eluent Generator and EPM are used to automatically produce potassium carbonate/bicarbonate eluents from deionized water. The EGC- K CO cartridge can only be controlled using Chromeleon. and subsequent Chromeleon releases. Suppressor Recommendations For optimum ease-of-use and economy, the IonPac AS column should be used with the ASRS Anion Self-Regenerating Suppressor, ASRS 00 or the Anion Atlas Electrolytic Suppressor, AAES. It is recommended to operate the IonPac AS column at an elevated temperature (0 C) to ensure reproducible retention times. Concentrator Columns For concentrator work, use the IonPac AG guard column, UTAC-LP, UTAC-ULP, UTAC XLP, UTAC-LP, UTAC-ULP, or UTAC-XLP, Ultra Trace Anion Concentrator Columns, TAC-LP or TAC-ULP Trace Anion Concentrator Column, TAC- Trace Anion Concentrator Column, or AMC- Anion Microconcentrator when a single-piston pump such as the AXP- pump (pulse damper required) is used for sample delivery. Use the UTAC-LP, UTAC-LP, Ultra Trace Anion Concentrator Column or TAC-LP Trace Anion Concentrator Column when the sample is delivered with a syringe or with a lowpressure autosampler such as the AS-DV. Product Description Part Number IonPac AS Analytical Column... 0 ( 0 mm) IonPac AG Guard Column ( 0 mm) IonPac AS Analytical Column... 0 ( 0 mm) IonPac AG Guard Column... 0 ( 0 mm) IonPac AS-Fast Analytical Column ( 0 mm) IonPac AG-Fast Guard Column ( 0 mm) IonPac AS-Fast Analytical Column ( 0 mm) IonPac AG-Fast Guard Column ( 0 mm) AMC- Anion MicroConcentrator ( mm) TAC- Trace Anion Concentrator ( mm) TAC-LP Low Pressure Trace Anion Concentrator ( mm) TAC-ULP Ultra Low Pressure Trace Anion Concentrator ( mm) UTAC-LP Ultra Trace Anion Concentrator Low Pressure ( mm) UTAC-ULP Ultra Trace Anion Concentrator Ultra Low Pressure... 0 ( mm) UTAC-XLP Ultra Trace Anion Concentrator Extremely Low Pressure ( mm) UTAC-LP Ultra Trace Anion Concentrator- Low Pressure ( mm) UTAC-ULP Ultra Trace Anion Concentrator- Ultra Low Pressure ( mm) UTAC-XLP Ultra Trace Anion Concentrator- Extremely Low Pressure ( mm) AS Sodium Carbonate/Bicarbonate Eluent Concentrate (0 ml of 00X concentrate)

8 Reagent-Free and RFIC are trademarks and ASRS, Atlas, Chromeleon and IonPac are registered trademarks of Dionex Corporation. PEEK is a trademark of Victrex Corporation. Passion. Power. Productivity. Dionex Corporation North America Europe 8 Titan Way U.S./Canada (8) 9-00 Austria () Benelux () ; () 9 Australia () 90 China (8) 8 8 India (9) P.O. Box 0 Denmark () France () Germany (9) 99 0 Japan (8) 88 Korea (8) 80 Singapore () Sunnyvale, CA South America Ireland () 00 Italy (9) 0 Sweden () 8 80 Taiwan (88) Brazil () 0 Switzerland () 0 99 United Kingdom () 9 LPN 8-0 0/0 (08) Dionex Corporation Asia Pacific

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS17-C Anion Exchange Column columns IonPac AS-C Anion Exchange Column The IonPac AS-C is a hydroxide-selective anion exchange column designed for fast gradient separation of inorganic anions. The key application for the AS-C column

More information

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS high-capacity, carbonate based anion-exchange column is designed for

More information

columns IonPac AS18 Anion-Exchange Columns

columns IonPac AS18 Anion-Exchange Columns columns IonPac AS Anion-Exchange Columns The IonPac AS is a hydroxideselective anion-exchange column designed for the determination of inorganic anions and low-molecularweight organic acids including fluoride,

More information

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is

More information

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS anion-exchange column is designed for the fast analysis of inorganic

More information

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes columns Thermo Scientific Dionex IonPac AS Anion-Exchange Column Isocratic Separation of Sulfur Species and Inorganic Anions Using the Dionex IonPac AS Column. Fluoride. Bromate. Chloride. Nitrite. Bromide.

More information

anion-exchange column

anion-exchange column columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride,

More information

Dionex IonPac AS28-Fast-4µm column

Dionex IonPac AS28-Fast-4µm column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column

More information

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection columns IonPac AS Anion-Exchange Column The IonPac AS is a highcapacity, hydroxide-selective anion exchange column designed for separation of haloacetic acids (HAAs) and bromate in drinking water prior

More information

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS4A Anion-Exchange Column Product Specifications Thermo Scientific Dionex IonPac AS4A anion-exchange column is designed for the separation of haloacetic

More information

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm

More information

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column Chromatography Thermo Scientific Dionex IonPac AS Anion-Exchange Column Product Specifications The Thermo Scientific Dionex IonPac AS column is a high-capacity, hydroxide-selective, anion-exchange column

More information

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water Thermo Scientific Dionex Ion Chromatography Solutions Global water safety bromate analysis in drinking water Safe drinking water public health assurance As a vital limited resource required for survival,

More information

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography Yan Liu, Zhongqing Lu, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA USA Overview Purpose: In this work, new high-pressure

More information

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s columns I o n P a c AS and AS-H C Anion-E x c h a n g e C o l u m n s The IonPac AS anion-exchange column provides fast profiling of inorganic anions and organic acid anions using sodium hydroxide or potassium

More information

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems Yan Liu, Zhongqing Lu, and Chris Pohl; Thermo Fisher Scientific, Sunnyvale, CA USA Overview

More information

columns IonPac SCS 1 Silica Cation Separator

columns IonPac SCS 1 Silica Cation Separator columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly

More information

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column chromatography Separate a wide variety of inorganic anions and organic acids using the Dionex IonPac AS and AS-HC Anion-Exchange Columns with potassium hydroxide gradients. Product Specifications Thermo

More information

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System arbara Shao, Frank Hoefler, Maria Rey, and Linda Lopez, Thermo Fisher Scientific,

More information

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm) columns and Trap Columns IonPac AG, AS, mm Eluent Source: EG Temperature: C IonPac AC ( mm) Flow Rate:. m/min Eluent: Potassium hydroxide, Inj. Volume: m, preconcentrated mm from to min, mm mm from min

More information

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System Application Update 55 Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free System Introduction Hydrogen peroxide is an essential chemical in the fabrication

More information

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples Application Note 79 Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples INTRODUCTION Cow s milk is of particular dietary value to infants,

More information

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production Thunyarat Phesatcha, Suparerk Tukkeeree, Jeff Rohrer 2 Thermo

More information

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column chromatography Obtain excellent peak shapes for hydrophobic amines without the use of solvent using the Dionex IonPac CS CationExchange Column. Product Specifications Thermo Scientific Dionex IonPac CS

More information

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Customer Application Note: 114 Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Sébastien N. Ronkart, Ph.D.; Société wallonne des eaux, rue de la

More information

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device Determination of Bromate in Bottled Mineral Water Using the CRD 00 Carbonate Removal Device Thunyarat Phesatcha, Weerapong Worawirunwong, and Jeff Rohrer Thermo Fisher Scientific, Bangkok, Thailand; Thermo

More information

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000 Evaluation of Various Anion-Exchange Chemistries for the Analysis of Haloacetic Acids in Drinking Water Using -D Matrix Elimination Ion Chromatography and Suppressed Conductivity Detection White Paper

More information

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection Barbara Shao, Terri Christison, Fei Pang, Cathy Tanner, and Frank Hoefler, Thermo Fisher Scientific, Sunnyvale,

More information

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection Determination of Tartaric cid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection Suparerk Tukkeeree, Chanita Chantarasukon, and Jeff Rohrer Thermo Fisher Scientific, angkok,

More information

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC TECHNICAL NOTE 122 Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC Authors Terri Christison and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA,

More information

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Inorganic Anions in Drinking Water by Ion Chromatography Determination of Inorganic s in Drinking Water by Ion Chromatography Peter Jackson Thermo Fisher Scientific Inc. Application Note Introduction The determination of common inorganic anions in drinking water

More information

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography Application Note 75 Determination of Sulfate and Chloride in Ethanol by Ion Chromatography Ethanol used as a blending agent in gasoline can be contaminated with chloride and sulfate that form plugging

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography Application Note 5 Determination of Inorganic Anions in Wastewater INTRODUCTION The determination of common inorganic anions in environmental waters, such as wastewater and drinking, ground, and surface

More information

suppressors Eluent Suppressors for Ion Chromatography

suppressors Eluent Suppressors for Ion Chromatography suppressors Eluent Suppressors for Ion Chromatography The Suppressor Advantage Dionex introduced suppression in 97, thereby bringing ion chromatography (IC) to the forefront of modern analytical techniques

More information

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below. Errata Product Manual for Dionex IonPac UTAC2 and AC-ER 065376-0 For new orders of the following parts discussed in this manual, please use the updated part numbers listed below. Part Old Part Number in

More information

Determination of trace anions in concentrated hydrofluoric acid

Determination of trace anions in concentrated hydrofluoric acid APPLICATION NOTE 78 Determination of trace anions in concentrated hydrofluoric acid Authors Archava Siriraks Thermo Fisher Scientific, Sunnyvale, CA Keywords HF, ICS-5000 +, IonPac AS10, IonPac AC10, ion

More information

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by PLC Deanna C. urum, Brian M. De Borba, and Jeffrey S. Rohrer Dionex Corporation, Sunnyvale, CA, USA ITRDUCTI Peptides perform

More information

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA Determination of Sub-μg/L Bromate in Municipal and Natural Mineral Waters Using Preconcentration with Two-Dimensional Ion Chromatography and Suppressed Conductivity Detection Brian DeBorba and Jeff Rohrer

More information

High-Performance Chromatography Superior isocratic separation of

High-Performance Chromatography Superior isocratic separation of columns I o n P a c C S A C a t i o n - E x c h a n g e C o l u m n The IonPac CSA cation-exchange column provides fast analysis of mono- and divalent cations, ammonium, and aliphatic amines simultaneously

More information

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column Application Note 95 Determination of Hydrochloride Purity Using the Acclaim PA Column INTRODUCTION -based medications are prescribed for several heart and blood pressure indications. The fastacting formulations

More information

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep pplication Note 70 Determination of Silicate in High Purity Water Using Ion Chromatography and utoprep Introduction The water used in the manufacture of semiconductors and other modern electronic components

More information

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection Terri Christison, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Overview

More information

Thermo Scientific Dionex eluent suppressors for ion chromatography

Thermo Scientific Dionex eluent suppressors for ion chromatography PRODUCT SPECIFICATIONS Thermo Scientific Dionex eluent suppressors for ion chromatography Suppression was introduced in 97, thereby bringing ion chromatography (IC) to the forefront of modern analytical

More information

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Direct Determination of Small Organic Acids in Sea Water by IC-MS Direct Determination of Small Organic Acids in Sea Water by IC-MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Application Note Key Words MSQ Plus Single Quadrupole Mass

More information

Inline sample preparation for the determination of anions in sodium hydroxide

Inline sample preparation for the determination of anions in sodium hydroxide APPLICATION UPDATE 72331 Inline sample preparation for the determination of anions in sodium hydroxide Authors Hua Yang and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Sample preparation,

More information

Utility of the Charge Detector in Ion Chromatography Applications

Utility of the Charge Detector in Ion Chromatography Applications Utility of the Charge Detector in Ion Chromatography Applications Mrinal K. Sengupta, Sheetal Bhardwaj, Kannan Srinivasan, Chris Pohl, and Purnendu K. Dasgupta Thermo Fisher Scientific, Sunnyvale, California,

More information

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below. Errata Product Manual for Dionex IonPac AS and AG Columns 03479-2 For new orders of the following parts discussed in this manual, please use the updated part numbers listed below. Part Old Part Number

More information

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components APPLICATION UPDATE 157 Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components Authors Sumate Pengpumkiat, Weerapong Worawirunwong,

More information

groups I and II cations, amines, divalent transition metals

groups I and II cations, amines, divalent transition metals IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography Application Note 9 Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography Introduction The computer, semiconductor, and food industries need analytical

More information

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities The power to increase productivity Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities RFIC System Technology Since the introduction of eluent generation in 99, Thermo Fisher

More information

Sample Preparation for Ion Chromatography

Sample Preparation for Ion Chromatography Sample Preparation for Ion Chromatography Comprehensive Solutions to Sample Preparation Challenges Now sold under the Thermo Scientific brand Choose from a Broad Range of Solutions No matter what your

More information

Overcoming Challenging Matrices in Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography Overcoming Challenging Matrices in Ion Chromatography Presented by: Kirk Chassaniol Gulf Coast Conference 2014 October 14, 2014 Thermo Fisher Scientific NA IC Tech Support 1 The world leader in serving

More information

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Trace Cations in Power Plant Waters Containing Morpholine Application Note 8 Determination of Trace Cations in Power Plant Waters Containing Morpholine INTRODUCTION Morpholine and ammonium are used as additives in power plant waters. Morpholine acts as a corrosion

More information

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column 38 LCGC LCGC NORTH NORTH AMERICA VOLUME NUMBER FEBRUARY 4 4 www.chromatographyonline.com Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column The United States

More information

suppressors SRS -ULTRA Self-Regenerating Suppressor

suppressors SRS -ULTRA Self-Regenerating Suppressor suppressors SRS -ULTRA Self-Regenerating Suppressor The Self- Regenerating Suppressor utilizes AutoSuppression technology to enhance analyte conductivity while suppressing eluent conductivity. This results

More information

for IonPac AG11-HC IonPac AS11-HC

for IonPac AG11-HC IonPac AS11-HC for IonPac AG-HC IonPac AS-HC IonPac AS-HC Manual Document No. 3333-7 Page of 45 PRODUCT MANUAL for the IONPAC AG-HC GUARD COLUMN (4 x 5 mm, P/N 59) ( x 5 mm, P/N 593) IONPAC AS-HC ANALYTICAL COLUMN (4

More information

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection Ian Acworth, Bruce Bailey, Paul Gamache, and John Waraska Thermo Fisher Scientific, Chelmsford, MA, USA Introduction

More information

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters PPLICTION NOTE 7229 Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters uthors Jingli Hu and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, C, US Keywords

More information

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator Technical Note 75 Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator Introduction The goal of every chromatographic optimization is a method that sufficiently resolves all

More information

ION CHROMATOGRAPHY SYSTEM S 150

ION CHROMATOGRAPHY SYSTEM S 150 ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved

More information

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry APPLICATION NOTE Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry AN43227 Antonella Guzzonato 1, Shona McSheehy Ducos

More information

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography Kirk Chassaniol Manager of IC Technical Sales Support Thermo Fisher Scientific 1 The world leader in serving

More information

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis Development of the Thermo Scientific Dionex IonPac AS Column for aloacetic ong Lin, Kannan Srinivasan, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA, USA Introduction aloacetic acids are a group

More information

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Marco Karsten, Bas, Dolman, Giovanni Maio, Frank Steiner, Holger Franz, Frank Arnold and Remco Swart LC Packings,

More information

Expanded capabilities in ammonium and amine detection

Expanded capabilities in ammonium and amine detection PRODUCT SPECIFICATIONS Thermo Scientifi c Dionex SC-CERS 500 Salt Converter-Cation Electrolytically Regenerated Suppressor Expanded capabilities in ammonium and amine detection Benefits Broadened ammonium

More information

IC Columns Introduction

IC Columns Introduction IC Columns Introduction Alltech IC Column Specifications Column Composition ph Range Applications Anion Exchange Columns Allsep polymer-based anion ph 0 inorganic anions, weak and strong acid ions, exchanger,

More information

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer Application Note 2 Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer INTRODUCTION Urea is commonly used in protein purification, including large scale purification

More information

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011 Ion Chromatography: Green Chemistry for a Green Environment Ken Kirkbride Somerset, New Jersey October 12, 2011 Ion Chromatography Ion Chromatography is an analytical technique that utilizes ion exchange

More information

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters Application Update 5 Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters INTRODUCTION For nuclear power plants using a pressurized water

More information

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography Harpreet Dhillon and John Statler Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 11 Introduction

More information

4. Ion chromatography (IC) 4.1. Educational aims and objectives

4. Ion chromatography (IC) 4.1. Educational aims and objectives 4. Ion chromatography (IC) 4.1. Educational aims and objectives Principles of ion chromatography method and instrumentation. Methods for ionic compounds analysis including ion chromatography and its subtypes.

More information

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA New Stationary Phases for Solid-Phase Extraction Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Purpose: To develop five new polymer-based stationary

More information

Determination of Monochloroacetic Acid in Carbocisteine

Determination of Monochloroacetic Acid in Carbocisteine Determination of Monochloroacetic Acid in Carbocisteine Zhong Xinlin, Ye Mingli, Liang Lina, Xu Qun, and Jeffrey Rohrer Thermo Fisher Scientific, Shanghai, People s Republic of China; Thermo Fisher Scientific,

More information

Determination of Methylamine in Drug Products

Determination of Methylamine in Drug Products Determination of Methylamine in Drug Products Thunyarat Phesatcha, Suparerk Tukkeeree, and Jeff Rohrer 2 Thermo Fisher Scientific, Bangkok, Thailand; 2 Thermo Fisher Scientific, Sunnyvale, CA, USA Application

More information

The Determination of Trace Anions in Concentrated Phosphoric Acid

The Determination of Trace Anions in Concentrated Phosphoric Acid Technical Note The Determination of Trace Anions in Concentrated Phosphoric Acid INTRODUCTION The determination of trace anions in phosphoric acid is hampered by a large excess of phosphate ion. Chloride

More information

Determination of Trace Anions in Organic Solvents

Determination of Trace Anions in Organic Solvents Application Note 8 Determination of Trace Anions in Organic Solvents INTRODUCTION In the manufacture of semiconductor materials, a great deal of attention is focused on minimizing sources of contamination.

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic

More information

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System Terri Christison, Charanjit Saini, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Technical

More information

IonPac Trace Cation Concentrator

IonPac Trace Cation Concentrator for the IonPac Trace Cation Concentrator (TCC-LP1, TCC-ULP1 and TCC-XLP1) Page 1 of 17 PRODUCT MANUAL FOR TRACE CATION CONCENTRATOR (TCC) TCC-LP1 Column Low Pressure, 4 x 35 mm (P/N 046027) TCC -ULP1 Column

More information

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Carl Fisher and Linda Lopez Thermo Fisher Scientific, Sunnyvale,

More information

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N ) PRODUCT MANUAL OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N 042151) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N 042153) OMNIPAC PAX-100 ANALYTICAL COLUMN (4 x 250 mm, P/N 042150) OMNIPAC PAX-500 ANALYTICAL

More information

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Application of Eluent Generation for Trace Anion Analysis of Borated Waters Application of Eluent Generation for Trace Anion Analysis of Borated Waters Edward Kaiser and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Application Note 166 Introduction Boric acid is used

More information

The determination of trace anions in concentrated phosphoric acid

The determination of trace anions in concentrated phosphoric acid TECHNICAL NOTE The determination of trace anions in concentrated phosphoric acid Authors Edward Kaiser and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Ion chromatography, IC, IonPac

More information

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2 Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2 Cooperative Chemical Analytical Laboratory College of Forestry Oregon State

More information

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Application Note Inorganic Ions, Water Testing, Minerals, Metals, Basic Chemicals Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography Authors Anne Mack, Adam Bivens

More information

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Determination of trace anions in organic solvents using matrix elimination and preconcentration APPLICATION UPDATE Determination of trace anions in organic solvents using matrix elimination and preconcentration Authors Terri Christison and Jeff Rohrer Thermo Fisher Scientific Sunnyvale, CA Keywords

More information

Determination of Additives in Carbonated Beverages

Determination of Additives in Carbonated Beverages pplication Note 9 Determination of dditives in Carbonated everages Introduction The soft drink industry is one of the largest in the world, with revenue from sales of carbonated soft drinks totaling billions

More information

IC5000 Ion Chromatography System

IC5000 Ion Chromatography System IC000 Ion Chromatography System Quaternary gradient pumping and on-line eluent preparation to improve separations in complex samples In-line sample filtration to 0.8 µm to eliminate manual filtrations

More information

New Developments in Surfactant Analysis Using HPLC

New Developments in Surfactant Analysis Using HPLC New Developments in Surfactant Analysis Using HPLC Rainer Bauder, Xiaodong Liu, Mark Tracy, and Christopher Pohl Dionex Corporation, Sunnyvale, CA USA Abstract This presentation provides the state-of-the-art

More information

Anion Exchange HPLC Columns

Anion Exchange HPLC Columns Anion Exchange PRP-X00 Polymeric anion exchange packings for separation of inorganic and organic anions. Easily separate the eight common anions (fluoride through sulfate). Good separation of fluoride

More information

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography L. Canella, C. Austin, A. Beavis, P. Maynard, M. Dawson, C Roux, and P. Doble Centre for Forensic Science, University of Technology,

More information

Advances in Sample Preparation for Accelerated Solvent Extraction

Advances in Sample Preparation for Accelerated Solvent Extraction Advances in Sample Preparation for Accelerated Solvent Extraction SM Rahmat Ullah, Kannan Srinivasan, and Chris Pohl, Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Purpose: To demonstrate the utility

More information

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography Application Note 44 Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography INTRODUCTION Perchlorate anion (ClO 4- ) is a water soluble, mobile, and persistent environmental

More information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE for the OnGuard- CARTRIDGE (OnGuard-RP, P/N 039595) (OnGuard-H, P/N 039596) (OnGuard-P, P/N 039597) (OnGuard-Ag, P/N 039637) (OnGuard-A, P/N 042102)

More information

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Determination of silicate in high-purity water using ion chromatography and online sample preparation PPLICTION NOTE 70 Determination of silicate in high-purity water using ion chromatography and online sample preparation uthors Weerapong Worawirunwong and Jeffrey Rohrer Thermo Fisher Scientific, Bangkok,

More information

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures. User Manual IonPac NS2 Columns 065501 Revision 02 October 2015 For Research Use Only. Not for use in diagnostic procedures. Product Manual for IonPac NS2 Columns IonPac NS2, 5µm, 4x250mm Analytical Column

More information

Ion Chromatography Validation for the Analysis of Anions in Gunshot Residue

Ion Chromatography Validation for the Analysis of Anions in Gunshot Residue Ion Chromatography Validation for the Analysis of Anions in Gunshot Residue Student Report Written for: Dr. Samide CH 424 November 22, 2010 Abstract The purpose of this study is to determine whether or

More information