The Evolving HPLC Column Packings
|
|
- Meagan Paul
- 5 years ago
- Views:
Transcription
1
2 The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established a very good reputation around the world. They are available with the same quality and the same performance anywhere in the world. Europe Asia North America Africa Oceania South America Inertsil Series Inertsil Series 00 Å 0 Å 0 m /g 0 m /g Inertsil ODS Inertsil ODS- Inertsil Ph etc. 80 Å 0 m /g Inertsil ODS-80A Inertsil Series InertSustain Series 00 Å 00 Å 0 m /g 0 m /g For Low Molecular For High Molecular 00 Å Inertsil WP Series : Inertsil WP00 C8 Inertsil WP00 C8 Inertsil WP00 C Inertsil WP00 DIOL Inertsil WP00 SIL Inertsil ODS- Inertsil ODS- Inertsil ODS-SP Inertsil ODS-P Inertsil ODS-EP Inertsil C8- Inertsil Ph- Inertsil CN- Inertsil HILIC Inertsil Amide Inertsil SIL-00A etc. 00 Å 0 m /g InertSustain InertSustain InertSustain InertSustain 00 m /g C8 C8 Phenyl NH InertSustainSwift C8 Base on Evolutionally Surfaced Silica (ES Silica) evolved from Inertsil, InertSustain has developed InertSustain employs a radically new type of silica, in which the surface of the silica is uniquely modified, the amount of silanols are controlled. Owing to this state-of-the-art technology ES silica allows easy surface modification including endcapping, which grants the following three favors.. Exceptionally improved inertness. Robust bonded phase. High reproducibility batch to batch Owing to above benefits InertSustain is recommended as the first choice column for almost all compounds analyzed. Batch to batch reproducibility Keeping on stable supplies with high quality and performance, GL Sciences continues to evolve. Year 0 TQ-68 Year 0 TQ-9 Year 0 TQ-6 Year 00 TQ-08 Year 009 TQ-86 Year 008 TQ-688 Year 007 TQ-6 Year 006 TQ-8 Year 00 TQ-9 Year 00 TQ-0 Year 00 TQ-97 Year 00 TQ-86 Year 00 TQ-688 Year 000 TQ- Year 999 TQ-6 Column : Inertsil ODS- ( μm, 0.6 mm I.D.) CHOH/HO=80/0,v/v.0 ml/min 0 C UV nm : : : : : ) Uracil ) Caffeine ) Phenol ) Butylbenzene ) o-terphenyl 6) Amylbenzene 7) Triphenylene
3 InertSustain C8 Physical Properties Silica : Newly Developed ES Silica Gel : μm, μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Octadecyl Groups End-capping : Complete Carbon Loading : % USP Code : L ph Range : ~0 Generally, silica based columns are mechanically stable and provide high effi ciencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain C8 employs a radically new type of silica, in which the surface of the silica is uniquely modifi ed, enabling precise control of the silica properties. InertSustain C8 inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high effi ciency and compatibility with a wide range of solvents), but now can be used for wide ph analysis with consistent performance from column to column and lot to lot. Figure : Basic Compounds InertSustain C8 X SELECT CSH C8 ZORBAX Eclipse Plus C8 Figure : Acidic Compounds No peak InertSustain C8 X SELECT CSH C8 ZORBAX Eclipse Plus C : μm, 0. mm I.D. : A) CHCN B) mm KHPO (ph 7.0, KHPO) A/B = 0/70, v/v : 0. ml/min : 0 C : UV 0 nm :. Uracil. Pyridine. Phenol. Berberine chloride. Dextromethorphan : μm, 0. mm I.D. : A) CHCN B) 0. % HPO A/B = /7, v/v : 0. ml/min : 0 C : UV nm :. Brilliant Blue FCF. Phenol. Salicylic acid Figure : Chelating Compound InertSustain C8 st Injection X SELECT CSH st Injection : No Peak : μm, 0.6 mm I. D. : A) CHCN B) 0. % HPO A / B = 0 / 60, v / v :.0 ml / min : 0 C : UV nm :. Hinokitiol Time (min) Time (min) nd Injection nd Injection Time (min) Time (min)
4 InertSustain C8 Comparison of Performance to Core-Shell Columns As shown below, core-shell columns show peak tailing due to the presence of trace metals or silanol groups in their silica gel. Quantitative and qualitative analysis will be a source of concern since the adsorption of compounds can be expected. InertSustain C8 µm Kinetex C8 (.7 μm) Intensity, cps.e.0e.0e Intensity, cps.e.0e.0e 0.0 Adsorption of Peak Column Injection Vol. : ODS Column(00. mm I.D.) : A) mm CHCOONH in 9 % CHCN B) mm CHCOONH in 0 % CHCN A / B = 0 / 80 - min 00 / 0 -. min 00 / min - 0 / 80, v / v (Mixed by a gradient mixer) : 0. ml / min : 0 C : LC / MS / MS (000 QTRAP : ESI, Positive, MRM) : 0 μl :. Nitrofurazone (00 μg / L). Lasalocid A (00 μg / L) Wide ph compatibility with Long Column Lifetime As shown in the experiment below, due to the introduction of Evolved Surface Silica, InertSustain C8 maintained high effi ciency and peak shape for 00 hours while other wide ph column brands failed InertSustain C8 Xterra MS C8 Gemini-NX 60 % Initial N Hours of Purging(h) Purging : μm, 0.6 mm I.D. : A)CHOH B)0 mm Triethylamine (ph 0.0) A/B = 0/70, v/v :.0 ml/min : 0 C Analytical : A) CHCN B) HO A/B = 6/, v/v :.0 ml/min : 0 C : UV nm : Naphthalene Experience the InertSustain! (Inertness and Sustainability) Highly end-capped ODS column such as InertSustain C8 offers an opportunity to fl ush out contaminants from the column surface easily using an organic solvent. Coffee melanoidins are brown heterogeneous polymers contained in coffee. Its components are not clarifi ed yet, but it is considered to contain several ionic compounds, which a poorly end-capped column will adsorb those ionic compounds leading to short column lifetime. As for ODS column, which is commonly used for HPLC and LC/MS/MS, its inertness has an infl uence not only on peak shape but also detection sensitivity and durability. It is highly recommended to use highly end-capped column which provides good peak shape for both basic and acidic compounds such as InertSustain C8. The packing material was visually confirmed by removing the column Before Experiment Brand A InertSustain C8 Flow Injection of Coffee After loading Coffee Still Contaminated After washing the column with CH CN 00 % 0 minute washing Ionic contaminants were hard to be washed out from the Column Clean!
5 InertSustain C8 Reliable Reproducibility, Performance and Quality Rigorous quality control of physical properties and strict chromatographic tests for inertness and selectivity, contribute to the production of InertSustain C8 with an outstanding reproducibility and long column lifetime. Strong Basic Compound Test Superior peak shape with highly reproducible chromatograms can be obtained even for those strong basic compounds. Lot. Same Retention Behavior between Various s µm 0.0 MPa Reliable reproducibility and same retention behavior between various particle size columns µm.8 MPa Lot. Lot. : µm, 0.6 mm I.D. : A) CHCN B) mm phosphate buffer (ph 7.0) A / B = 0 / 60, v / v :.0 ml / min : 0 C : UV 0 nm :. Dextromethorphan µm. MPa : 0. mm I.D. : A) CHOH B) mm phosphate buffer (ph 7.0) A / B = 0 / 70, v / v : 0. ml / min : 0 C : UV 0 nm :. Uracil. Pyridine. Phenol. Berberine chloride. Dextromethorphan Strong Acidic Compound Test Strong Chelating Compound Test Lot. Lot. Lot. Lot. Lot. Lot : µm, 0.6 mm I.D. : A) CHCN B) 0. % HPO A / B = / 7, v / v :.0 ml / min : 0 C : UV nm :. Brilliant Blue FCF. Phenol. Salicylic acid : µm, 0.6 mm I.D. : A) CHCN B)0. % HPO A / B = 0 / 60, v / v :.0 ml / min : 0 C : UV nm :. Hinokitiol
6 InertSustain C8 Analytical Columns : μm HPSeries : μm 0 MPa (00 Bar) Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * UHPLC compatible end-fi ttings are also available upon request for UHPLC systems (Ex: UPLC) to avoid dead volume. * Indicate UP Type end-fi ttings when ordering. (Please note that UP type is not available for a.6 mm I.D. column) * For maximum operating pressure information, please refer to page 6. Length \ I.D : μm Length \ I.D Length \ I.D : μm Length \ I.D * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , For 0 mm Length Holder for Cartridge Guard Column E For 0 mm Length * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6.
7 InertSustainSwift TM C8 Physical Properties Silica : Newly Developed ES Silica Gel :.9 μm, μm, μm Surface Area : 00 m /g Pore Size : 00 Å (0 nm) Pore Volume :.00 ml/g Bonded Phase : Octadecyl Groups End-capping : Complete Carbon Loading : 9.0 % USP Code : L ph Range :.0~0.0 As shown in figure, InertSustainSwift C8 maintains the same extreme inertness, wide ph range and provide rapid separations with symmetric peaks. The optimization of surface area, pore size and chemical bonding delivers superior peak shapes (Figure ). Figure proves InertSustainSwift C8 is also ideal for LC/MS/MS applications which offer highly sensitive results and enables MS compatible buffers to be used due to the extremely inert silica gel. Figure : Comparison of Retentivity. min InertSustainSwift C8 (.9 μm) InertSustain C8 ( μm). min : 0. mm I.D. : A) CHOH B ) HO A/B = 80/0, v/v : 0. ml/min : 0 C : UV nm :. Uracil. Toluene. Ethylbenzene. Propylbenzene. n-butylbenzene 6. n-amylbenzene Figure : Comparison of Efficiency 7. MPa N : 600 N : MPa N : 00 N : 900 : 0. mm I.D. : A) CHOH B) HO A/B = 0/70, v/v : 0. ml/min : 0 C : UV nm :. Pyridine. Phenol.0.0 InertSustainSwift C8 (.9 μm) Figure : Rapid LC/MS/MS Analysis of Basic Drugs Complete Separation in 60 Seconds.0.0 Acguity BEH C8 (.7 μm) Column : InertSustainSwift C8(.9 μm, 0. mm I.D.) : A) 0 mm Ammonium Formate in HO B) 0 mm Ammonium Formate in CHOH A/B = 70/0 0. min - 0/60 0. min - 0/00 0. min 0/ min -70/0-0. min - 70/0,v/v : 0.6 ml/min : 0 C : LC/MS/MS (ESI, Positive, MRM) :. Acebutolol. Atenolol. Labetalol. Nadolol. Pindolol
8 InertSustainSwift C8 Analytical Columns :.9 μm HP Series : μm Max. Operating Pressure : 0 MPa (00 Bar) * End-fi ttings are /6 Parker style. * For maximum operating pressure information, please refer to page 6. Length / I.D Length / I.D Length / I.D : μm Length / I.D Length / I.D : μm Length / I.D * End-fi ttings are /6 Parker style. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , For 0 mm Length Holder for Cartridge Guard Column E For 0 mm Length * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6.
9 InertSustain C8 Physical Properties Silica : Newly Developed ES Silica Gel : μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Octyl Groups End-capping : Complete Carbon Loading : 8 % USP Code : L7 ph Range : ~ 0 IInertSustain C8 is an octyl group (C8) bonded column delivering the same extreme inertness to any type of compounds just like InertSustain C8, which enables rapid analysis of highly hydrophobic compounds delivering symmetric peaks at a wide range of ph. Figure : Comparison of Retentivity between InertSustain C8 and InertSustain C8 9.9 min 6. min 6 : μm, 0.6 mm I.D. : A)CHOH B)HO A/B = 80/0, v/v :.0 ml/min : 0 C : UV nm :. Uracil. Toluene. Ethylbenzene. Propylbenzene. n-butylbenzene 6. n-amylbenzene InertSustain C InertSustain C8 Figure : Analysis of Losartan Potassium and Hydrochlorothiazide Tablets, Assay Test (Based on the Condition of United States Pharmacopeia 6-NF) Column Col.Temp. InjectionVol. : InertSustainC8( μm,0.0 mm I.D.) : A)CHCN/Buffer* = 7/9,v/v(Premix) B)CHCN A/B=00/0 min 9/8 6min 8/6 min 00/0 min 00/0,v/v :.0mL/min : C : UV80 nm(gl-70 UV Detector) : 0 μl :. Hydrochlorothiazide 0. mg/ml. Losartan Potassium 0. mg/ml Tailing factor of :.79 ( <.) * Buffer :. g/l of monobasic potassium phosphate and. g/l of dibasic sodium phosphate n water
10 InertSustain C8 Analytical Columns : μm HPSeries : μm 0 MPa (00 Bar) Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * UHPLC compatible end-fi ttings are also available upon request for UHPLC systems (Ex: UPLC) to avoid dead volume. * Indicate UP Type end-fi ttings when ordering. (Please note that UP type is not available for a.6 mm I.D. column) * For maximum operating pressure information, please refer to page 6. : μm : μm Length \ I.D Length \ I.D Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , Holder for Cartridge Guard Column E * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. For 0 mm Length For 0 mm Length
11 InertSustain Phenyl Physical Properties Silica : Newly Developed ES Silica Gel : μm, μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Phenyl Groups End-capping : None Carbon Loading : 0 % USP Code : L ph Range : ~ 7. InertSustain Phenyl delivers an extremely unique reverse phase characteristics that are critical to resolving compounds that could not be separated on a C8 or C8 phase. InertSustain Phenyl provides not only pi-pi interactions, but also hydrogen bonding secondary interactions, which results in retaining polar compounds at the same time. As the phenyl groups are directly bonded to the silica gel, InertSustain Phenyl is compatible with the analysis of structural isomers due to it s high stereo-selectivity (fi gure ) while other alkyl phenyl type columns fails to separate. Figure : Comparison of Selectivity between InertSustain Phenyl and InertSustain C8, InertSustain Phenyl InertSustain C8 : μm, 0.6 mm I.D. : A) CHOH B) HO A/B = 70/0, v/v : 0.8 ml/min :0 C : UV nm. Butylbenzene. o -Terphenyl. Amylbenzene. Triphenylene Non - Planar Structure Planar Structure Figure : Analysis of Structural Isomers (Positional Isomers of Cresol),, Not Separated Not Separated InertSustain Phenyl Ascentis Phenyl XBridge Phenyl : μm, 0.6 mm I.D. : A)CHOH B)HO A/B = 0/80, v/v : 0 C : 0.8 ml/min : UV nm OH OH OH CH CH CH. o-cresol. m-cresol. p-cresol
12 InertSustain Phenyl Analytical Columns : μm HPSeries : μm 0 MPa (00 Bar) Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * UHPLC compatible end-fi ttings are also available upon request for UHPLC systems (Ex: UPLC) to avoid dead volume. * Indicate UP Type end-fi ttings when ordering. (Please note that UP type is not available for a.6 mm I.D. column) * For maximum operating pressure information, please refer to page 6. : μm : μm Length \ I.D Length \ I.D Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , Holder for Cartridge Guard Column E * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. For 0 mm Length For 0 mm Length
13 InertSustain Phenylhexyl Physical Properties Silica : Newly Developed ES Silica Gel : μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Phenylhexyl Groups End-capping : Yes Carbon Loading : 9.0 % USP Code : L ph Range :.0 ~ 0.0 InertSustain Phenylhexyl columns are bonded with phenylhexyl groups, which employs a phenyl ring with a hexyl (6- carbon) linker and is densely bonded to our newly developed ES silica gel delivering complementary selectivity to straight alkyl-chain columns, but with industry leading inertness, lot-to-lot reproducibility and low back pressure. Figure : Comparison of Selectivity with other brands, 7, , InertSustain Phenylhexyl : μm, 0.6 mm I.D. : A) CHOH B) HO A/B = 70/0, v/v :.0 ml / min : 0 C : UV nm :. Uracil. Caffeine. Phenol. Butylbenzene. o-terphenyl 6. Amylbenzene 7. Triphenylene XBridge Phenyl Luna Phenyl-Hexyl Figure : Analysis of Acidic Compounds InertSustain Phenylhexyl XBridge Phenyl Luna Phenyl-Hexyl : μm, 0.6 mm I.D. : A) CHCN B) 0.% HPO A/B = /7, v/v :.0 ml/min : 0 C : UV nm :. Brilliant Blue FCF. Phenol. Salicylic acid 0 0 0
14 InertSustain Phenylhexyl Analytical Columns HP Series : μm 0 Mpa(00 Bar) Length \ I.D * End-fi ttings are /6 Waters-compatible. * UHPLC compatible end-fi ttings are also available upon request for UHPLC systems (Ex: UPLC) to avoid dead volume. * Indicate UP Type end-fi ttings when ordering. (Please note that UP type is not available for a.6 mm I.D. column) * For maximum operating pressure information, please refer to page 6. : μm : μm Length \ I.D Length \ I.D Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , Holder for Cartridge Guard Column E * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. For 0 mm Length For 0 mm Length
15 InertSustain NH Physical Properties Silica : Series Newly Developed ES Silica Gel : μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Aminopropyl Groups End-capping : None Carbon Loading : 7 % USP Code : L8 ph Range : ~ 7. InertSustain NH is a newly developed ES silica column, compare to the other normal silica columns, InertSustain NH performs a sharp peaks, and high reproducible results with exceptional stability and durability that will maintain performance over the lifetime of the method. Also, InertSustain NH is an easily equilibrate column. Figure is an analysis sample to show the equilibrate time of InertSustain NH column. Using an column was replaced with isopropanol, phthalic acid ester as the sample and measured the time until stabilized the analysis conditions. From the chromatogram we can know at the total fl ow time of minutes of th injection, the column was stabled to be analyze. Figure : Analysis of Vitamin E with InertSustain NH & Inertsil NH column. α-tocopherol. β-tocopherol. γ-tocopherol. δ-tocopherol FLU InertSustain NH FLU Inertsil NH R= Column Injection Vol. : μm, 0.6 mm I.D. : A) n-hexane B) Ethyl acetate A/B = 8/, v/v :. ml/min : 0 C : FL Ex. 98 nm Em. nm : 0 μl : α-tocopherol ( μg/ml in Hexane) β-tocopherol ( μg/ml in Hexane) γ-tocopherol ( μg/ml in Hexane) δ-tocopherol ( μg/ml in Hexane) (C6H) Figure : Evaluation of equilibration time st injection (0 min) 0 6 Di-n-propylphthlate nd injection (7 min) 0 6 rd injection ( min) 0 6 Diethy phthalate th injection ( min) 0 6 Column : InertSustain NH ( μm, 0.6 mm I.D.) : A) n-hexane/isopropanol = 00/, v/v B) Isopropanol A/B = 9/, v/v (gradient mixer) :.0 ml/min : 0 C : UV 00 nm th injection (8 min) 0 6
16 InertSustain NH Physical Properties Silica : Newly Developed ES Silica Gel : μm, μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore Volume : 0.8 ml/g Bonded Phase : Aminopropyl Groups End-capping : None Carbon Loading : 7 % USP Code : L8 ph Range : ~ 7. InertSustain NH shows far superior stability compared to other brand available aminopropyl columns, as our newly developed Evolved Surface Silica is chemically bonded with aminopropyl group. Generally, aminopropyl columns are used for applications that are hard to be separated in a reversed phase mode, such as simultaneous analysis of sugars or vitamin E. However, the shift in retention time has been an issue for a long time. InertSustain NH delivers highly reliable reproducibility and stability with accurate qualitative and quantitative results. Further more, aminopropyl columns generally can not be washed by weakly acidic eluent, however InertSustain NH was improved and it can be washed by weakly acidic eluent. Figure : Comparison of preventing anomer resolution of sugar analysis : A) CHCN B) HO A/B = 7/ :.0 ml/min, v/v : 0 C : RI :. Fructose ( mg/ml). Glucose ( mg/ml). Sucrose ( mg/ml). Maltose (0 mg/ml) InertSustain NH other brand Amide Column Figure : Comparison of stability between various Amino column Figure : Reliable reproducibility 0 InertSustain NH 00 Other Brands NH Column A Other Brands NH Column B Initial retention time (%) Lot. 80 Lot : μm, 0.6 mm I.D. :.0 ml/min : 0 C : RI Volume of eluent passing through the column (ml) :. Maltose : μm, 0.6 mm I.D. : A)CHCN B)HO A/B = 8/, v/v :.0 ml/min : 0 C : RI :. Fructose. Glucose. Sucrose. Moltose
17 InertSustain NH Analytical Columns : μm : μm Length \ I.D Length \ I.D Length \ I.D Length \ I.D * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. Cartridge Guard Column E I.D. of the Analytical Column Applicable Length I.D. Replacement Cartridge E Guard Column ( EA.) Cartridge E Holder / Cartridge Set ( Cartridge E Guard Columns & Holder) μm μm μm μm , , , , , Holder for Cartridge Guard Column E * End-fi ttings are /6 Waters-compatible. * For maximum operating pressure information, please refer to page 6. For 0 mm Length For 0 mm Length
Method Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationInertSustainSwift C8
Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)
More informationAN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties
AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationInertsil Technical Library
HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions
More informationAn HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint
An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar
More informationInertsil ODS-EP Technical Information
Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can
More informationState-of-the-art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%
More informationReversed Phase Columns. SEC Columns. Ion Exchange Columns. Application Specific Columns. Guard Columns. HILIC Columns. Normal Phase Columns.
C o n t e n t s Column Selection Overview Ex Reversed-Phase Column Selection Guide Ex5 Selectivity Comparison of Reversed-Phase Ex7 Normal-Phase Column Selection Guide Ex0 Column Specifications...Ex Conforming
More informationState - of - the -art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with
More informationLC800. Smart HPLC. Until now UHPLC From now Smart HPLC
LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution
More informationInertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases
HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationIon Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog
Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationAdvantages of polymerbased. an alternative for ODS
Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,
More informationPacked Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents
No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationThe Selection of an HPLC Column October
The Selection of an HPLC Column 07. ctober Long-Term Collaboration + 30 Years of Experience GL Sciences Inc. HPLC Selection of an HPLC Column 3 Contents. How to Select an HPLC Column How to select your
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and
More informationACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:
More informationHPLC UHPLC Columns. Dikma Technologies Inc.
Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate
More informationHypersil BDS Columns TG 01-05
TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide
More informationTechnical Guide Thermo Scientific Syncronis HPLC Columns
Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationRP C18 column with feature of a silanol group
RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise
More informationINERTSIL (GL Sciences)
Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area
More informationfor Acclaim Mixed-Mode HILIC-1 Column
for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationThermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time
Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationH P L C C O L U M N S
H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil
More informationSuccessfully Scaling and Transferring HPLC and UPLC Methods
Successfully Scaling and Transferring HPLC and UPLC Methods Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 6288 Fax: +358-9-5659 6282 Waters Finland Kutomotie 16 00380 Helsinki 2013 Waters Corporation
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS Inertsil Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationUptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules
Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim
More informationTracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability
Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass
More informationSample Preparation Products General Catalogue. Sample Preparation Products General Catalogue
Sample Preparation Products General Catalogue Sample Preparation Products General Catalogue Solid Phase Cross Reference 3 Objective of Solid Phase Extraction 4 5 Usage of Solid Phase Extraction 6 7 SPE
More information8. Methods in Developing Mobile Phase Condition for C18 Column
I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely
More information( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k
Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationProntoSIL C18-EPS Reversed-Phase HPLC Columns
ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive
More informationCapital HPLC Columns and HPLC Cartridges. Optimal HPLC Range
Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationACE Ultra Inert Base Deactivated HPLC Columns
ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-
More informationHPLC column C18 C8 PFP. SunShell. Core Shell Particle
HPLC column C8 C8 PFP SunShell Core Shell Particle ChromaNik Technologies Inc. SunShell is a core shell silica column made by ChromaNIk Technologies. The next generation to Core Shell particle Features
More informationOverview Applications of NUCLEODUR HPLC Phases
verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More informationZirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions
Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell
More informationOrosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.
Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible
More informationAgilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX Technical Note Agilent s SampliQ WAX provides Applications for strongly acidic, acidic and neutral compounds Excellent
More informationTransferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM
Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM Eric S. Grumbach Thomas E. Wheat Chuck Phoebe Joe Arsenault Jeffrey R. Mazzeo Diane M. Diehl UPLC TECHNOLOGY
More informationHPLC Column. Technical Guide
HPLC Column Technical Guide (1) Introduction P 1 (2) Specifications P 1 ~ 4 (3) Shipping Solvent P 5 ~ 8 (4) Mobile Phase P 9 ~ 11 (5) Sample Diluent/Injection Solvent P 12 (6) Column Cleaning and Storage
More information1.7 m Fortis UHPLC Columns
Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower
More informationCLIPEUS - A Small Shield for a Big Job
CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,
More informationImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC
ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com
More informationLC Column Troubleshooting. Do you have an equivalent column for my LC column?
LC Column Troubleshooting Do you have an equivalent column for my LC column? LC columns from different suppliers may have very different retention properties even if the bonding is the same. Although there
More informationColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns
ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationAcclaim HILIC-10 Columns
Thermo Scientific Acclaim HILIC- Columns Product Manual P/N: January 3 Part of Thermo Fisher Scientific Product Manual for Acclaim HILIC- Analytical Column Acclaim HILIC-, 3 µm, Analytical, 4.6 x 5 mm
More informationN α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)
A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary
More informationNovel LC/MS-Compatible Stationary Phase with Polar Selectivity
Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based
More informationzorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax
Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column
More informationComparison Guide to C18 Reversed Phase HPLC Columns
Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According
More informationKromasil Eternity Designed for long life. For use in HPLC and UHPLC
Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s
More informationPhenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationBarry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000
Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 0, 000 HPLC Column Troubleshooting What Every HPLC User Should Know :00 a.m. EST Telephone Number: 86-650-06 Chair Person: Tim Spaeder
More informationCOMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications
COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According
More informationFluophase and Fluofix Columns
TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for
More informationTechnical Information
356 Miscellaneous Miscellaneous 357 Technical Information Contents Column Handling... 358-360 Mobile Phases for Reversed Phase Columns... 361 HPLC Column Performance... 362 Inspection Reports... 363 FAQ...
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationHPLC Column Material - Bulk Ware
HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationNUCLEOSHELL core-shell silica for HPLC
NUCLESHELL core-shell silica for HPLC Core-shell technology µm 0. µm.8 µm 0. µm.7 µm 0. µm.7 µm 0. µm Key feature Solid core of silicon dioxide, homogeneous shell of porous silica Highest efficiency compared
More informationNew Product Update. HPLC Columns
New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna
More informationThe Standard for ph Method Development
The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged
More informationImprove Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application
Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward
More information1.7µm Fortis UHPLC Columns
Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency
More informationSPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods
How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular weight, etc., determine
More information(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted
Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion
More informationCation Exchange HPLC Columns
Cation Exchange HPLC Columns Hamilton offers seven polymeric packing materials for cation exchange separations. Type Recommended Application(s) PRP-X00 PRP-X00 PRP-X800 HC-0 HC-7 Ca + HC-7 H + HC-7 Pb
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationSample Preparation TLC Plates
TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC
ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,
More informationAcclaim Mixed-Mode WAX-1 Columns
User Manual Acclaim Mixed-Mode WAX- Columns 06565 Revision 03 October 05 Product Manual for the Acclaim Mixed-Mode WAX- Column Page of 3 Product Manual for Acclaim Mixed-Mode WAX- Columns 5µm, 0 x 50 mm,
More informationChoosing Columns and Conditions for the Best Peak Shape
Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include
More informationHigh Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>
High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have
More informationFast Separation of Vastly Different Compounds by Isocratic HPLC
Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite
More information