HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited

Size: px
Start display at page:

Download "HICHROM. Chromatography Columns and Supplies. LC COLUMNS Inertsil. Catalogue 9. Hichrom Limited"

Transcription

1 HICHROM Chromatography Columns and Supplies LC COLUMNS Inertsil Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0) Fax: + (0) sales@hichrom.co.uk

2 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences Inertsil Series Enhanced sensitivity High resolution Excellent for acidic, basic and chelating compounds Compatible with up to 00% aqueous eluents Inertsil Series Phases Phase Endcapped Particle Size (μm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) ODS- and ODS-V Yes,, 00 0 C8- Yes,, 00 0 The Inertsil series is based on enhanced deactivation techniques which produce highly inert silica, enabling successful analysis of trace levels of the most demanding basic and acidic compounds. Strictly classified particle size, with narrow distribution width and an ideal carbon loading, enables high efficiency columns to be guaranteed. Figure illustrates the high sensitivity LC-MS/MS separation of haloacetic acids, harmful substances generated when tap water is chlorinated. Inertsil ODS- and C8- columns also show excellent stability during the analysis of strong metal chelating compounds. Figure shows the separation of tetracyclines, veterinary antibiotics with very strong chelating characteristics. The μm phases are also available in High Pressure (HP) format. Please enquire for details. Column: Inertsil ODS- (μm, 0 x.mm) Eluent: A: CH OH B: 0.% HCOOH Gradient: A/B = /9.min /9.min 9/ min 9/ Flow rate: 0.ml/min Temperature: 0 C 6 Detection: LC-MS/MS (ESI, negative, MRM). Bromoacetic acid. Dibromoacetic acid. Tribromoacetic acid. Chloroacetic acid. Dichloroacetic acid 6. Trichloroacetic acid 7. Bromochloroacetic acid Column: Inertsil ODS- (μm, 7 x.mm) Eluent: CH OH B: 0.% HCOOH Gradient: A/B = 0/80.min 0/80 min 9/.min 9/ Flow rate: 0.ml/min Temperature: 0 C Detection: LC-MS/MS (ESI, positive, MRM). Tetracycline (TC). Oxytetracycline (OTC). Chlortetracycline (CTC). Doxycycline (DC) Mins Mins Figure. Analysis of haloacetic acids by LC-MS/MS Figure. Analysis of tetracyclines by LC-MS/MS Ordering Information Inertsil Series Column Dimensions (mm) Guard Cartridges (/pk) 0 x. 0 x. 7 x. 00 x. 0 x. 0 x. (0 x.mm) μm ODS C μm ODS C ODS-V μm ODS C Column Dimensions (mm) Guard Cartridges (/pk) 0 x.6 0 x.6 7 x.6 00 x.6 0 x.6 0 x.6 (0 x.0mm) μm ODS C ODS-V μm ODS C ODS-V Other dimensions available Use with guard cartridge holder ( 97) sales@hichrom.co.uk Tel:

3 GL Sciences Inertsil Series High purity base silica (99.999%) Large surface area Exceptional stability and column lifetime Validated ODS- column Compared with Inertsil Series, Inertsil Series phases are based on a purer, higher surface area silica which is specially manufactured to provide maximum phase coverage. The result is a series of columns which provide excellent peak shapes using simple eluents while operating at low pressure. Inertsil Series Phases Phase Endcapped Particle Size (μm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Recommended ph Range* SIL -, ODS- Yes,,,, ODS-V Yes, ODS-P No, ODS-EP No Peptide C8 Yes ODS-Sprint Yes, Sulfa C8 Yes, C8- Yes,, Ph- No,, CN- No, NH No, Diol No, HILIC No, Amide No, AX No CX No *Inertsil phases are known to provide excellent results at ph levels of 9 0. However, optimum column life may be achieved at a ph between and 7.. Inertsil ODS- Peak tailing of basic components in reversed-phase is frequently the result of residual silanol groups. GL Sciences developed a proprietary bonding endcapping technology to eliminate these silanols. To ensure maximum inertness, each batch of Inertsil ODS- must pass a QC test using 9 Si NMR. After ODS bonding, the magnitude of the isolated silanols is greatly decreased. After endcapping, the isolated silanols have been completely eliminated, thereby assuring excellent inertness and optimum performance of ODS- (see Figure ). Isolated silanol Si-OH Silica-gel structure Si-(O-Si) ODS group C 8 H 7 -Si-O- Remaining silanol Endcapped groups (CH ) -Si-O- Geminal silanol Si-(OH) For free technical advice and support technical@hichrom.co.uk Bare silica gel support After ODS bonding After ODS bonding and endcapping Figure. Measurement of residual silanol groups by 9 Si NMR Inertsil ODS-V a validated Inertsil column Inertsil ODS-V is a highly efficient, validated HPLC column, developed to provide optimum separation for a wide range of acidic and basic compounds. Each lot of packing undergoes a series of critical QC analytical tests, consistent with the demands of GLP/GMP compliance, to confirm: ) the absence of surface silanols ) minimal metallic residues ) inertness to basic compounds ) reproducible separations. Norephedrine. Nortriptyline. Toluene. Imipramine. Amitriptyline Column dimensions: 0 x.6mm Flow rate: ml/min. Eluent: CH OH - mm KH PO, ph 6 (60:0) Temperature: C Figure 6. Separation of antidepressant drugs on Inertsil ODS-V Mins 08

4 GL Sciences Inertsil Series (continued) Inertsil ODS-P Polymerically bonded C8 Improved separation of planar compounds Useful for carotenoid analysis Separation of the 6 EPA PAHs Inertsil ODS-P is a polymerically bonded phase which is densely bonded with octadecylsilane groups. It shows unique separation capabilities and offers an alternative selectivity to Inertsil ODS-. Inertsil ODS-P is particularly suited to the separation of polycyclic aromatic hydrocarbons and shows additional retentivity for planar compounds. Figure 7 shows the separation of terphenyl isomers on three types of ODS phases. On the polymeric Inertsil ODS-P phase, the planar p-terphenyl is retained longer than the non-planar o- and m- isomers. Figure 8 shows the separation of components from toad venom on the ODS-P phase. o-terphenyl (non-planar) m-terphenyl (non-planar) p-terphenyl (planar) m- m- m- Column dimensions: 0 x.6mm Eluent: CH CN - H O (8:) Flow rate: ml/min Temperature: 0 C Detection: UV, nm o- p- o- p- o- p Mins Monomeric (Inertsil ODS-) Intermediate (Inertsil ODS-) Polymeric (Inertsil ODS-P) Figure 7. Separation of terphenyl isomers Column: Inertsil ODS-P (0 x.6mm) Eluent: CH CN - 0.% H PO (:) Flow rate: ml/min Temperature: 0 C. Bufalin. Resibufogenin. Cinobufagin. Indomethacin Mins Figure 8. Separation of toad venom Inertsil ODS-EP C8 with polar embedded group Compatible with 00% aqueous eluents Alternative selectivity to C8 Ideal for LC-MS Inertsil ODS-EP Uracil Column dimensions: 0 x.6mm Eluent: CH CN - H O (70:0) Flow rate: ml/min Column temperature: 0 C Figure 9. Comparison of Inertsil ODS-EP and C8 columns* *The comparative separations presented here may not be representative for all applications. Inertsil ODS-EP contains a polar functional group embedded between the silica surface and the C8 group. This creates a stable phase, which is resistant to phase collapse (or pore dewetting) in 00% aqueous eluents. It provides highly reproducible separations for acids and bases in organic eluents as well as acidified eluents typically used in LC-MS. Figure 9 shows a comparison of the selectivity of Inertsil ODS-EP with that of a C8 phase. Ethylbenzene Naphthalene Propylbenzene Butylbenzene Anthracene Uracil Naphthalene Ethylbenzene Propylbenzene Alkyl-C8 Anthracene Butylbenzene sales@hichrom.co.uk Tel:

5 GL Sciences Inertsil Series (continued) Inertsil ODS-Sprint Balanced retention of polar and non-polar compounds Compatible with 00% aqueous eluents Low back pressure Inertsil ODS-Sprint is super base deactivated and optimally bonded to retain polar compounds without excessive retention of non-polar compounds. This phase shows excellent peak shapes for a wide range of polar analytes, including both basic and acidic compounds. In Figure 0 the hydrophobic compounds are eluted in approximately two-thirds the time of Inertsil ODS-, whilst maintaining retention of polar compounds. Inertsil ODS-Sprint operates at low back pressures, even at high flow rates and shows excellent robustness and reproducibility. Column: Inertsil ODS-Sprint and Inertsil ODS- Column dimensions: 0 x.6mm Eluent: CH OH - H O (80:0) Flow rate: ml/min Temperature: 0 C Inertsil ODS-Sprint 6 7. Uracil. Caffeine. Phenol. n-butylbenzene. o-terphenyl 6. n-amylbenzene 7. Triphenylene Column: Inertsil Peptide C8 (00 x.mm) Eluent: A: H O - CH CN (9:) + 0.0% TFA B: CH CN - H O (80:0) + 0.0% TFA Gradient: - 0% B in 0 mins Flow rate: 0.ml/min Sample: 60pmol cytochrome C tryptic digest 7 Inertsil ODS Mins Mins Figure 0. Polar and non-polar mixture Figure. Analysis of cytochrome C tryptic digest on Inertsil Peptide C8 Inertsil Peptide C8 The Inertsil Peptide C8 column is specifically suited to the analysis of peptide digests. Figure shows the application of this column to the analysis of cytochrome C tryptic digest. Inertsil Sulfa C8 Inertsil Sulfa C8 ( and μm) is designed for the analysis of sulpha drugs. In addition, it is effective in the screening of synthetic antibacterial agents and residues in products of animal origin, as directed by food safety investigative guidelines. Each batch of Inertsil Sulfa C8 is tested for the effective separation of sulpha drugs, as shown in Figure. For free technical advice and support technical@hichrom.co.uk Figure. Analysis of sulfa reagents Mins 0 Column: Inertsil Sulfa C8 (µm, 0 x.6mm) Eluent: A: CH CN CH CO H - (777.66:., w/w) B: CH CO H H O (.:997, w/w) 00% B to 67% B in mins then to 0% B in mins Flow rate: ml/min Temperature: 0 C Sample: ppm each. Sulfanilamide. Sulfacetamide. Sulfadiazine. Sulfathiazole. Sulfapyridine 6. Sulfameradine 7. Sulfacymidine 8. Sulfamethoxypyridazine 9. Sulfamonomethoxine 0. Sulfachlorpyridazine. Sulfamethoxazole. Sulfabenzamide. Sulfadimethoxine. Sulfaquinoxaline. Sulfanitran 0

6 GL Sciences Inertsil Series (continued) Inertsil HILIC Unique selectivity for polar compounds High sensitivity LC-MS analyses Low back pressure Applications for amino acids, water-soluble vitamins and drug metabolites Inertsil HILIC is a propyl alcohol bonded silica phase, suitable for the analysis of polar compounds in the hydrophilic interaction (HILIC) mode. It has also shown promise in SFC applications. Unlike traditional reversed-phase materials, HILIC columns retain highly polar compounds with only small amounts of water in the eluent. The high organic solvent composition of the eluent will lead to high sensitivity LC-MS analyses, due to a decrease in ion suppression. It also results in low back pressure and the ability to run at high flow rates. Figure shows the separation of a mixture of oligosaccharides on Inertsil HILIC. Inertsil HILIC has also been used in the development of a fast and sensitive LC-MS/MS method for the analysis of melamine and cyanuric acid contaminants in pet food samples (see Figure ). Column: Inertsil HILIC (µm, 0 x.6mm) Eluent: CH CN - H O (6:) Flow rate: ml/min Temperature: 0 C. Maltose. Maltotriose. Maltotetraose. Maltopentaose. Maltohexaose 6. Maltoheptaose Column: Inertsil HILIC (0 x.0mm) Eluent: A: 0mM ammonium acetate in CH CN B: 0mM ammonium acetate in H O Gradient: T(mins) %A %B Flow rate: 0.ml/min Temperature: 0 C Detection: MS/MS (ESI) 6 Cyanuric Acid (Negative ESI) Melamine (Positive ESI) Mins Mins Figure. Analysis of oligosaccharides on Inertsil HILIC Figure. Analysis of melamine and cyanuric acid on Inertsil HILIC Inertsil Amide Excellent for polar compounds in HILIC mode Ideal for LC-MS/MS Long column lifetime Inertsil Amide is a carbamoyl bonded silica phase designed for the separation of highly polar compounds by HILIC. Inertsil Amide columns offer significantly increased retentivity and a unique selectivity in separating compounds that were unresolvable on other columns. Column: Inertsil Diol (0 x.6mm) Eluent: CH CN - H O (80:0) Flow rate: ml/min Column temperature: 0 C Inertsil Diol Unique selectivity in both reversed-phase and normal-phase Applications for amino acids, water-soluble vitamins and sugars 6. Phenylalanine. Methionine. Valine. Dopa. Alanine 6. Serine 7. Citrulline 7 The Inertsil Diol phase is a dihydroxypropyl bonded silica which can be used in both reversed-phase and normal-phase modes. Figure shows the analysis of free amino acids on an Inertsil Diol column. Figure. Analysis of free amino acids sales@hichrom.co.uk Tel:

7 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences Inertsil Series (continued) Inertsil Ion-Exchange Phases Silica based ion-exchange columns High reproducibility High efficiency Exceptional stability and long column lifetime Inertsil AX and CX are silica based anion- and cation-exchange phases respectively, based on high purity silica. They show good reproducibility, exceptional stability and long column lifetime. Figure 6 shows the separation of nucleotides on Inertsil AX and Figure 7 shows the analysis of nucleic acid bases by cation-exchange chromatography on Inertsil CX. Column: Inertsil AX (0 x.6mm) Eluent: 0.0M KH PO (ph.0 with H PO ) Flow rate: ml/min Temperature: 0 C N(CH CH ) C 6 H SO - H + AX bonded phase structure CX bonded phase structure Column: Inertsil CX (0 x.6mm) Eluent: 0.M ammonium formate, ph.0 Flow rate: ml/min Temperature: 0 C. CMP. AMP. UMP. GMP. XMP. Uracil. Thymine. Guanine. Cytosine. Adenine Mins Mins 0 Figure 6. Analysis of nucleotides on Inertsil AX Figure 7. Analysis of nucleic acid bases on Inertsil CX Ordering Information Inertsil Series Inertsil ODS- (Hichrom Manufactured Columns) Column Dimensions (mm) 00 x.6 0 x.6 0 x.6 ODS- μm INODS--00D 07 INODS--0D 9 INODS--0D 6 ODS- μm INODS-00D INODS-0D 7 INODS-0D 07 Please contact Hichrom for availability of other Series phases and alternative dimension columns. Microbore (.mm i.d.) Columns (GL Sciences Manufactured) Column Dimensions (mm) 0 x. 0 x. 7 x. 00 x. 0 x. μm C ODS Ph For free technical advice and support technical@hichrom.co.uk Column Dimensions (mm) Guard Cartridges (/pk) 0 x. 00 x. 0 x. 0 x. (For.mm i.d. Columns) μm C ODS ODS-P ODS-Sprint Ph CN NH Diol SIL HILIC Amide Other column dimensions available Use with free standing holder ( 97)

8 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences Ordering Information Inertsil Series (continued) Microbore (.mm i.d.) Columns (GL Sciences Manufactured) (continued) Column Dimensions (mm) 0 x. 00 x. 0 x. 0 x. Guard Cartridges (/pk) (For.mm i.d. Columns) μm ODS-V Sulfa C μm ODS μm C ODS ODS-P ODS-EP ODS-Sprint Ph CN NH Diol SIL HILIC Amide Sulfa C AX CX Peptide C Medium bore (.0mm i.d.) Columns (GL Sciences Manufactured) Column Dimensions (mm) 0 x.0 0 x.0 7 x.0 00 x.0 0 x.0 μm C ODS Ph Column Dimensions (mm) Guard Cartridges (/pk) 0 x.0 00 x.0 0 x.0 0 x.0 (For.0mm i.d. Columns) μm C ODS ODS-P ODS-Sprint Ph CN NH Diol SIL HILIC Amide ODS-V Sulfa C μm ODS Other column dimensions available Use with free standing holder ( 97) sales@hichrom.co.uk Tel:

9 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences For free technical advice and support technical@hichrom.co.uk Ordering Information Inertsil Series (continued) Medium bore (.0mm i.d.) Columns (GL Sciences Manufactured) (continued) Column Dimensions (mm) Guard Cartridges (/pk) 0 x.0 00 x.0 0 x.0 0 x.0 (For.0mm i.d. Columns) μm C ODS ODS-P ODS-EP ODS-Sprint Ph CN NH Diol SIL HILIC Amide ODS-V Sulfa C AX CX Peptide C Analytical (.6mm i.d.) Columns (GL Sciences Manufactured) Column Dimensions (mm) Guard Cartridges (/pk) 0 x.6 00 x.6 0 x.6 0 x.6 (For.6mm i.d. Columns) μm C ODS ODS-P ODS-Sprint Ph CN NH Diol SIL HILIC Amide ODS-V Sulfa C ( ) ( 6) ( 8) ( 09) μm ODS μm C ODS ODS-P ODS-EP ODS-Sprint Ph CN NH Diol SIL HILIC Amide ODS-V Sulfa C ( 6) AX CX Peptide C Other column dimensions available Use with free standing holder ( 97)

10 GL Sciences Inertsil Wide Pore Phases High purity 00Å silica phases Excellent reproducibility Good physical and chemical stability Inertsil Wide Pore Phases Inertsil WP00 Particle Size Surface Area Carbon Load Bonding Endcapped Pore Size (Å) Phase (μm) (m /g) (%) ph Range SIL C Polar embedded butyl Yes C8 Octyl Yes C8 Octadecyl Yes Diol Propyldiol No The Inertsil WP00 series of columns has been developed for the analysis and purification of proteins and peptides. It currently consists of five phases, which are available in column dimensions ranging from capillary to preparative. Inertsil WP00-C8 and C8 show high separation efficiency for peptides and proteins of medium molecular size (recommended <,000 Da for C8 phase and <0,000 Da for C8 phase). Inertsil WP00-C can elute hydrophobic proteins >,000 Da with excellent peak shape due to the shielding effects of embedded polar groups. Figure 8 shows the separation of a polypeptide mixture on Inertsil WP00-C8. Please contact Hichrom for ordering information for Inertsil wide pore phase columns. Column: Inertsil WP00-C8 (0 x.6 mm) Eluent: A: H O (0.% TFA) B: CH CN-H O (90:0) (0.% TFA) Gradient: A:B 80:0 to 0:60 over mins Temperature: 0 C. Ribonuclease. Insulin. Cytochrome. Lysozyme. BSA 6. Trypsin Inhibitor from Soybean 7. Ovalbumin Mins Figure 8. Analysis of polypeptide mixture Capillary and Nano Columns Excellent efficiency and column-to-column reproducibility Easy installation Easy coupling with MS GL Sciences produce a range of capillary and nano columns for high sensitivity trace analyses. These columns are available for InertSustain, Inertsil Series, Inertsil Series and Inertsil wide pore materials as well as Titansphere products, which are designed specifically for applications involving phosphopeptide extractions (see page 8). The Capillary EX columns are available in 0., 0. and 0.7mm i.d. and 0 or 0mm lengths. These columns are packed using glass-lined stainless steel tubing of / o.d. and come with stainless steel end fittings. Capillary EX-Nano columns are available with 0.0, 0.07, 0. and 0.mm i.d. with lengths of 0, 0 and 0mm. These columns are packed using fused silica tubing and inserted into / 6 o.d. PEEK tubing for protection, with stainless steel end fittings. Please contact Hichrom for ordering information for Inertsil Capillary EX and Capillary EX-Nano columns. sales@hichrom.co.uk Tel:

11 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences Inertsil Series and Inertsil ODS Spherical porous silica Excellent for acidic and basic molecules Well referenced in the scientific literature Inertsil Series and Inertsil ODS Phases Functional Group Endcapped Particle Size (μm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) ODS- Octadecyl Yes C8 Octyl Yes C Butyl Yes Phenyl Phenyl Yes ODS* Octadecyl Yes 00 0 * From original Inertsil series The well established Inertsil Series phases are based on high purity silica which is robust and shows high reproducibility from batch-to-batch and column-to-column. Ordering Information Hichrom Manufactured Columns Microbore (.0mm i.d.) Columns Column Dimensions (mm) Guard Cartridges 0 x.0 00 x.0 0 x.0 0 x.0 (For.0mm i.d. Columns) ODS- INODS-0M 7 INODS-00M 90 INODS-0M 0 INODS-0M INODS-0CE 0 (/pk) C INC-0M INC-00M INC-0M 6 INC-0M 9 INC-0CE 0 (/pk) Phenyl INP-0M 8 INP-00M 00 INP-0M INP-0M INP-0CE 0 (/pk) Microbore (.mm i.d.) Columns Column Dimensions (mm) Guard Cartridges 0 x. 00 x. 0 x. 0 x. (For.mm i.d. Columns) ODS- INODS-0AM 0 INODS-00AM 6 INODS-0AM 80 INODS-0AM 0 INODS-0CM 0 (/pk) C INC-0AM 0 INC-00AM INC-0AM 0 INC-0AM 70 INC-0CM 0 (/pk) Phenyl INP-0AM 60 INP-00AM 7 INP-0AM 90 INP-0AM 0 INP-0CM 0 (/pk) Medium Bore (.mm i.d.) Columns Column Dimensions (mm) 0 x. 00 x. 0 x. 0 x. Guard Cartridges (For.mm i.d. Columns) ODS- INODS-0AS INODS-00AS 0 INODS-0AS INODS-0AS 8 INODS-0C 0 (/pk) C INC-0AS 8 INC-00AS 00 INC-0AS INC-0AS INC-0C 0 (/pk) Phenyl INP-0AS INP-00AS 0 INP-0AS 6 INP-0AS 9 INP-0C 0 (/pk) Analytical (.0mm i.d.) Columns For free technical advice and support technical@hichrom.co.uk Column Dimensions (mm) Guard Cartridges 0 x.0 00 x.0 0 x.0 0 x.0 (For.0mm i.d. Columns) ODS- INODS-0AF INODS-00AF 0 INODS-0AF INODS-0AF 8 INODS-0C 0 (/pk) C INC-0AF 8 INC-00AF 00 INC-0AF INC-0AF INC-0C 0 (/pk) Phenyl INP-0AF INP-00AF 0 INP-0AF 6 INP-0AF 9 INP-0C 0 (/pk) Analytical (.6mm i.d.) Columns Column Dimensions (mm) Guard Cartridges 0 x.6 00 x.6 0 x.6 0 x.6 (For.6mm i.d. Columns) ODS- INODS-0A INODS-00A 0 INODS-0A INODS-0A 8 INODS-0C 0 (/pk) C INC-0A 8 INC-00A 00 INC-0A INC-0A INC-0C 0 (/pk) Phenyl INP-0A INP-00A 0 INP-0A 6 INP-0A 9 INP-0C 0 (/pk) Other column dimensions available please enquire Use with free-standing holder HI-6 ( ) and column coupler HI-08 ( 6) see p. Starter kits ( ) also available see p. Semi-Preparative and Preparative (7.7.mm i.d.) Columns Please contact Hichrom for further details of 7.7.mm i.d. Inertsil columns. 6

12 Please contact Hichrom for current prices. Tel: + (0) sales@hichrom.co.uk GL Sciences Ordering Information GL Sciences Manufactured Columns (Inertsil Series and Inertsil ODS) Microbore (.mm i.d.) Columns Column Dimensions (mm) Inertsil μm Phase 0 x. 0 x. Guard Cartridges (/pk) (For.mm i.d. Columns) ODS C Phenyl C ODS Medium Bore (.0mm i.d.) Columns Inertsil μm Phase Column Dimensions (mm) Guard Cartridges (/pk) 0 x.0 0 x.0 (For.0mm i.d. Columns) ODS C Phenyl C ODS Analytical (.0 and.6mm i.d.) Columns Inertsil μm Phase Column Dimensions (mm) Guard Cartridges (/pk) 0 x.0 0 x.0 0 x.6 0 x.6 (For.0 and.6mm i.d. Columns) ODS C Phenyl C ODS Other column dimensions available Use with free-standing holder ( 97) sales@hichrom.co.uk Tel:

INERTSIL (GL Sciences)

INERTSIL (GL Sciences) Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

State - of - the -art C18 HPLC Columns

State - of - the -art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase -New For State - of - the -art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Sample Preparation TLC Plates

Sample Preparation TLC Plates TLC PLATES TLC Plates Economical separation method High sample throughput Pilot procedure for HPLC and flash chromatography Versatile range of ready-to-use layers Thin layer chromatography (TLC) is a simple,

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog Ion Exchange ---- Inertsil AX 078 Inertsil CX 080 HPLC Column Catalog 077 Inertsil AX Physical Properties Silica : Series High Purity Silica Gel : μm Surface Area : 0 m /g Pore Size : 00 Å (0 nm) Pore

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9. HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Extraction - SOLA & HyperSep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Thermo Scientific Acclaim Catalogue The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0) 0 0 Fax: + (0) Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Shodex. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Catalogue 9 Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies SAMPLE PREPARATION Solid Phase Extraction - Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 930 3660 Fax: +44

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

Advantages of polymerbased. an alternative for ODS

Advantages of polymerbased. an alternative for ODS Advantages of polymerbased HPLC columns an alternative for ODS Yukiko Higai Shodex, 1 Content (1) Comparison between Silica and Polymer-based RP columns (2) Characteristics of Polymer RP columns - an example:

More information

H P L C C O L U M N S

H P L C C O L U M N S H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil

More information

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC ImpSilHPLC Columns The solution for your chromatography IMPTECH SCIENTIFIC 7-1-60,203-Veena Dharam Karam Road,Ameerpet,Hyderabad-500 016 Tel:040-23740443/483 Ph:9848051071 imptechscientific@gmail.com www.impscience.com

More information

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

ProntoSIL HPLC Columns

ProntoSIL HPLC Columns ProntoSIL HPLC Columns For Technical Assistance Call -800--708 analytical inc. To Order and For More Information: Call FAX -800--708-0-8-99 -0-8-99 We ship nearly 00% of your orders the same day they are

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

It s hot! ZIC -chilic

It s hot! ZIC -chilic It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass

More information

HPLC Column Material - Bulk Ware

HPLC Column Material - Bulk Ware HPLC Column Material - Bulk Ware Constantly growing demands on separation efficiency and availability of solid phase material for packing HPLC columns and column packing stations have motivated us to provide

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

Shodex TM ODP2 HP series columns

Shodex TM ODP2 HP series columns HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series

More information

Too Polar for Reversed Phase What Do You Do?

Too Polar for Reversed Phase What Do You Do? Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed

More information

Sepax SRT -C, Zenix -C SEC Phases

Sepax SRT -C, Zenix -C SEC Phases Sepax SRT -C, Zenix -C SEC Phases Complimentary Phases to SRT for Derivatized Monoclonal Antibodies General Description Stationary Phase Structure SRT, Zenix, SRT-C and Zenix-C SEC phases developed based

More information

design: black sheep t: Reliable & reproducible performance every time - Guaranteed

design: black sheep t: Reliable & reproducible performance every time - Guaranteed design: black sheep t: 029 2049 0722 Reliable & reproducible performance every time - Guaranteed Accurate & quantitative data Affordable price Reproducibility Wide application range HPLC Column Requirements

More information

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase

AQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase AQUASIL C8 Columns AQUASIL 8 Columns TG0-0 Compatible with 00% aqueous mobile phase AQUASIL OH OH AQUASIL C8 columns provide a versatile C8 phase for a wide range of application areas. AQUASIL C8 columns

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

CLIPEUS - A Small Shield for a Big Job

CLIPEUS - A Small Shield for a Big Job CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

High Performance Liquid Chromatography

High Performance Liquid Chromatography Updated: 3 November 2014 Print version High Performance Liquid Chromatography David Reckhow CEE 772 #18 1 HPLC System David Reckhow CEE 772 #18 2 1 Instrument Basics PUMP INJECTION POINT DETECTOR COLUMN

More information

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

Epic Aromatic Selectivity

Epic Aromatic Selectivity Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Cation Exchange HPLC Columns

Cation Exchange HPLC Columns Cation Exchange PRP-X00 Polymeric cation exchange packing for separation of inorganic cations and organic cations. Easily separate mono or divalent cations. ph stable from to. Use with organic solvent

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

RP C18 column with feature of a silanol group

RP C18 column with feature of a silanol group RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column pharmaceutical #9 Applications note Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column Mixtures of nucleotides, nucleosides, and their respective purine

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Acclaim Mixed-Mode WCX-1

Acclaim Mixed-Mode WCX-1 Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion

More information

Method Development with ZirChrom's Ion Exchange Phases

Method Development with ZirChrom's Ion Exchange Phases For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

Strength in Technology

Strength in Technology Strength in Technology Fortis C8 Excellent Peak Shapes Superb Quantitation ph Range - Fully Scalable 3,5,0μ C8 7% Fortis C8 is designed to provide characteristics which will aid in increased productivity

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

for Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1 for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z

Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Packed columns for reversed-phase chromatography TSKgel ODS-100V and 100Z Contents Page 1. Introduction 2 2. Specifications and characteristics 2 3. Properties of packing material 3 4. Chromatographic

More information

TCI Dual ~Mixed-Mode Mode column~

TCI Dual ~Mixed-Mode Mode column~ TCI Dual ~Mixed-Mode Mode column~ TCI Chromatography Department Mixed-Mode Column Target compound is basic Choose DS + Cation-Exchange Type Target compound is acidic Choose DS + Anion-Exchange Type o ion-pair

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Passion. Power. Productivity.

Passion. Power. Productivity. - - Passion. Power. Productivity. Acclaim Acclaim Acclaim PA/PA Acclaim A Acclaim Acclaim PA Acclaim Explosives rdering and Warranty Information In the U.S. All rders Including: Credit Card rders (VISA,

More information

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) Ch.28 HPLC 28.1 Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography) High Performance (Pressure) LC Glass column st.steel (high

More information

Comparison of different aqueous mobile phase HPLC techniques

Comparison of different aqueous mobile phase HPLC techniques June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

Columns and supplies catalog

Columns and supplies catalog Columns and supplies catalog PLC GC TLC SPE and lash Syringe filters Vials and caps... we Meet your Needs MACEREY-NAGEL Company profile Since 1911 MACEREY-NAGEL has represented high quality, innovation

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,

More information

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information