GPS1B. Characteristics. Technical performances

Size: px
Start display at page:

Download "GPS1B. Characteristics. Technical performances"

Transcription

1 Thermal and magnetic protection PS Motor protection devices Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics Rocker and rotary handle operator Thermal and magnetic protection Standard and high capacity cu = 0k cs = 0% cu cu < 0k cs min. 7% cu lear identification of the operation state (ONOtripped) mbient temperature compensation Phase failure protection culus uxiliaries Technical performances ccessories uxiliaries usbar system Technical data imensions useless starters oordination tables pg.. pg.. pg.. pg..2 pg.. pg.. Rated current n Rated operational current e () Rated power at ac Utilisation category 0972 (circuit breaker) 097 (MMS) Tripping class 097 Magnetic release e max. Mechanical/electrical endurance () (kw) () x 0,000.2

2 LSS PS Standard capacity Rated power phase motors at ac Pn (kw) Rated current n () () Thermal current setting range () nstantaneous release () Rated ultimate cu (k) Rated service cs (k) at. no. Ref. no. Pack. LSS / / / () Rated current: highest thermal current setting range value. PS igh capacity. Rated power phase motors at ac Pn (kw) / / /. 7. Rated current n () () Thermal current setting range () nstantaneous release () Rated current: highest thermal current setting range value. () Rated ultimate cu (k) Rated service cs (k) PSS PSS PSS PSS PSS PSS PSS PSS PSSJ PSSK PSSL PSSM PSSN PSSP PSSR at. no. PS PS PS PS PS PS PS PS PSJ PSK PSL PSM PSN PSP PSR Ref. no Pack. Order codes.

3 Thermal and magnetic protection PS2 Motor protection devices Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics Rotary handle operator Thermal and magnetic protection Standard and high capacity cu = 0k cs = 0% cu cu < 0k cs min. 7% cu lear identification of the operation state (ONOtripped) mbient temperature compensation Phase failure protection culus uxiliaries Technical performances Rated current n Rated operational current e Rated power at ac Utilisation category 0972 (circuit breaker) 097 (MMS) Tripping class 097 Magnetic release e max. Mechanical/electrical endurance () () (kw) () 0 x,000/,000 ccessories uxiliaries usbar system Technical data imensions useless starters oordination tables pg.. pg.. pg.. pg..2 pg.. pg...

4 LSS PS2 Standard capacity Rated power phase motors at ac Pn (kw) Rated current n () () Thermal current setting range () nstantaneous release () Rated ultimate cu (k) Rated service cs (k) at. no. Ref. no. Pack. / PS2SK PS2SL PS2SM PS2SN PS2SP PS2SR PS2SS PS2ST PS2SU LSS () Rated current: highest thermal current setting range value. PS2 igh capacity Rated power phase motors at ac Pn Rated current n () Thermal current setting range nstantaneous release Shortcircuit Shortcircuit at. no. Ref. no. Pack. Order codes (kw) / () 0 () () cu (k) 0 0 cs (k) 0 0 PS2K PS2L PS2M PS2N PS2P PS2R PS2S PS2T PS2U () Rated current: highest thermal current setting range value..

5 Technical data eneral data rame size PS PS2 Motor protection devices Rated insolation voltage Ui Rated operating voltage Ue Rated impulse withstand strength Uimp Rated frequency Total power loss P (W) Utilisation category: 972 (ircuit breaker) 97 (Motor starter) Mechanical operational performance lectrical operational performance Max.operations per hour (motor startup) mbient conditions: Storage temperature Operation temperature Temperature compensation mbient temperature compensation Operational altitude Shock resistance ( ) Vibration resistance Shock hazard prot. (acc.n V 0) Protection degree (acc.to 29) ac kv /0z 0. to 7W.W at. 0,000 (70,000 for ) 0,000 (70,000 for ) 0 to +0 to +0 to +0 up to 00m 0g (width ms) g ( to z) fingerproof P 00V ac kv /0z up to W 0 to W 7W at.,000,000 0 to +0 to +0 to +0 up to 00m 0g (width ms) g ( to z) fingerproof P (P with acc PPTP2) Rated current e Overload protection Phase failure protection Tripping class Magnetic release (factory set) Test trip button Standards & pprovals 97 / 2 / N V 00T 0 / / 2 UL UL type culus / S / N / i Shipping approvals up to 97 x emax Only PS* n process up to 97 x emax Mounting data Terminal capacity: Solid or stranded without end sleeve Stranded with end sleeve W Operating mechanism lockable in O position diameter (mm) Terminal type Tightening torque Screwdriver Mounting: Nrail Screws Operating position: turning to the front turning to the back turning to both sides x... mm 2 2 x... mm 2 or 2 x... mm 2 x / 2 x. to. screw 2 Nm / Lb.in Pz2 / slotted combination no or 2 x... mm 2 x mm 2 / 2 x mm 2 x 2 / 2 x. to. box Nm / Lb.in Pz2 / slotted combination andle operation imensions width (mm) height (mm) depth (mm) Rocker level / Rotary 90 (PS*S) 7 / 92. (PS*) Rotary 7..

6 .9 Technical data Ultimate capacity (cu) in k or ranges PSS* / PSMS* Rated current () 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V J K L M N P R 0 0 S 0 0 T 0 U 0 or ranges PS2S* / PS2MS* or ranges PS2* / PS2M* or ranges PS* / PSM* Shortcircuit proof with an cu = 0k or k Rated service capacity (cs) in k Rated current () 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V 2/20V 00/V 0V 0/V J K L M N P R S T 9 0 U 9 0 ackup fuses are necessary in case of possibility of a current higher than 0k or k at the installation point of the device (on request) cs = 0%cu when cu = 0k cs = 7%cu when cu < 0k or ranges PSS* / PSMS* or ranges PS2S* / PS2MS* or ranges PS2* / PS2M* or ranges PS* / PSM*

7 . Motor protection devices ackup gl/g fuses only if cs > cu (k) gl/g fuses () 20V 0V 0V 20V 0V 0V 20V 0V 0V 20V 0V 0V J. 0 0 K 0 0 L 0 0 M N P R S T U PS* or ranges PSS* / PSMS* or ranges PS2S* / PS2MS* or ranges PS2* / PS2M* or ranges PS* / PSM* ackup gl/g fuses only if cs > cu (k) Manual motor starter: PS... Manual motor starter: PS2...

8 Specific letthrough energy at Ue = 00/ V Manual motor starter: PS... Manual motor starter: PS2... Technical data Peak current limitation at Ue = 00/ V Manual motor starter: PS... Manual motor starter: PS2....2

9 Mounting possibilities of the auxiliaries Motor protection devices Wiring diagram rontal auxiliaries uxiliary contact block larm contact block Type NO or N NO or N escription Two frontal auxiliary contact blocks can be installed at the same time maintaining the overall width of the manual motor starter. nstalled on the frontal right side. an be mounted in combination with the frontal auxiliary block. The overall width of the manual motor starter is maintained. Lateral auxiliaries uxiliary contact block 2NO NO + N 2N ifferent catalogue numbers for left or right mounting. Maximum number of auxiliary contact blocks mounted on each side: 2. Total number of auxiliary contacts in combination frontal and lateral:. Width of each lateral auxiliary contact block: 9 mm. PS rated at allows maximum 2 auxiliary contact blocks ( contacts). uxiliary/alarm contact block NO (alarm) + NO (auxiliary) NO (alarm) + N (auxiliary) N (alarm) + NO (auxiliary) N (alarm) + N (auxiliary) nstalled on the left side. Maximum number of blocks per manual motor starter:. an be fitted together with one lateral auxiliary contact block or one shortcircuit alarm block mounted on the left side. Width of each lateral alarm/auxiliary contact block: 9 mm. Shortcircuit alarm contact block NO + N nstalled on the left side. Tripping in case of only. an be fitted together with one lateral auxiliary contact block or one auxiliary/ alarm block mounted on the left side. Width of each alarm contact block: 9 mm. Shunt trip nstalled on the right side. an not be mounted together with the undervoltage release or any lateral block mounted on the same side. Width of each shunt trip: mm. Undervoltage trip nstalled on the right side. an not be mounted together with a shunt trip device or any lateral block mounted on the same side. Width of each undervoltage trip: mm Undervoltage trip with 2NO early make auxiliary contacts nstalled on the right side. Two different types, one for the PS*S.. and another for the PS*..and PS2.. an not be mounted together with a shunt trip device or any lateral block mounted on the same side. Width of each undervoltage trip: mm. Shunt trip, undervoltage trip and undervoltage with 2NO contacts can be mounted together with any frontal block or left lateral block with above mentioned restrictions.22

10 uxiliaries atalogue reference P*.. ux. frontal block P*L.. PL.. P.. P.. ux. lateral block larm frontal block larm/aux. lateral block Shortcircuit alarm block ont. cap. contacts class (UL) 00 / Q00 00 / P00 00 / Q00 00 / P00 00 / P00 ackup fuses g, gl Rated operating voltage Ue (Vac) Rated operational current () Utilization category Rated operating voltage Ue (Vdc) Rated operational current () Utilization category Mounting side Terminals capacity: Solid or stranded without end sleeve W Terminal type Tightening torque Screwdriver imensions width (mm) ront 2x0. 2. mm 2 2x screw 0.Nm Pz2/Slotted Maintain same width Left or right 2x0. 2. mm 2 2x screw 0.Nm Pz2/Slotted ncrease width 9 mm Mounting data rontal right 2x0. 2. mm 2 2x screw 0.Nm Pz2/Slotted Maintain same width Left 2x0. 2. mm 2 2x screw 0.Nm Pz2/Slotted ncrease width 9 mm Left 2x0. 2. mm 2 2x screw 0.Nm Pz2/Slotted ncrease width 9 mm Technical data atalogue reference Power consuption: Pickup (V/W) old (V/W) Operating voltage Tripping (V) Pickup (V) Max. operation supply (ms) PU Undervoltage trip 2/2 /.2 0.Ve0.7Ve 0.Ve.Ve PS Shunt trip 2/2 0.7Ve.Ve () Rated operating voltage Ue ontacts class (UL) ackup fuses (g,g) 2V z 2V 0z V z V 0z /27V z / V 0z V 0z 2/20V z / /20V 0z V z / 277V 0z 0/ z /0V z / 0/0V 0z 0V z / 0z 2V /0z V 0z V z / 0V 0z /27V z / V 0z V 0z 2/20V z / /20V 0z V z / 277V 0z 0/ z /0V z / 0/0V 0z 0V z / 0z 2 to 0Vdc to Vdc Mounting side Terminals capacity: Solid or stranded without end sleeve W Terminal type Tightening torque Screwdriver Right 2x0. 2. mm 2 2x Screw 0.Nm Pz2/Slotted Mounting data Right 2x0. 2. mm 2 2x Screw 0.Nm Pz2/Slotted imensions width (mm) ncrease width mm etailed dimensions see page. ncrease width mm.2

11 imensional drawings Manual Motor Starter PS rocker Motor protection devices Manual Motor Starter PS rotary Manual Motor Starter PS2.2

12 uxiliary contact blocks rontal uxiliary contact blocks Lateral imensions larm contact blocks rontal larm contact blocks Lateral Shunt and undervoltage trip devices Shortcircuit contact block.

13 imensional drawings PS rocker + Undervoltage trip device with 2NO contacts Motor protection devices PS rocker + uxiliaries PS rotary + uxiliaries PS2 + uxiliaries.2

14 xternal handle operator Load side imensions Type pplicable frame.27

Surion. Motor protection devices. Thermal and magnetic protection GPS1B. Standards/Approvals. Characteristics. Auxiliaries. Technical performances

Surion. Motor protection devices. Thermal and magnetic protection GPS1B. Standards/Approvals. Characteristics. Auxiliaries. Technical performances Thermal and magnetic protection PS Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics Rocker and rotary

More information

Redline Unibis : the solution Circuit protection

Redline Unibis : the solution Circuit protection 2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board

More information

NM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- /

NM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- / P0. Type designation N M / Type of Npole for P breaker* pplication: lank: for power distribution; : for motor protection elease type and accessory code (please refer to table on page 9) Number of poles

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,

More information

5SP and 5SY Supplementary Protection UL 1077

5SP and 5SY Supplementary Protection UL 1077 Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth

More information

Redline Edition Modular DIN-rail devices and residential enclosures. Just feel protected. GE Consumer & Industrial Power Protection

Redline Edition Modular DIN-rail devices and residential enclosures. Just feel protected. GE Consumer & Industrial Power Protection onsumer & Industrial Power Protection dition Modular INrail devices and residential enclosures Just feel protected imagination at work . Selection table of Miniature ircuit reakers (M s). Technical data.

More information

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 0 V 2 reaker amily Y - mpere rame - mpere rame K - 2 mpere rame L - mpere rame M

More information

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 6 0 V reaker amily Y - mpere rame - 0 mpere rame K - 0 mpere rame L - mpere rame M 00

More information

UL 1077 DIN Rail Supplementary Protectors

UL 1077 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

NR2 Thermal Overload Relay

NR2 Thermal Overload Relay Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping

More information

Cat. No. 140M-F M-D8E-B

Cat. No. 140M-F M-D8E-B Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures ...5..8.0....8.0....8.0....5 Five good reasons to appreciate the EG MCB's Benefits of the MCB's Series E90 Selection table Series E90N Miniature circuit breakers k Series E90E Miniature circuit breakers.5k

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

Miniature circuit breakers. Residual current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residual current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures Residual current circuit breakers B...5 Five good reasons to appreciate the EG MCBs Benefits of the MCBs Series E90 Selection table Busbar systems C..8.....8.... Series E90N k Series E90E.5k Series E90

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

SIRCOVER Manual transfer switches from 125 to 3200 A

SIRCOVER Manual transfer switches from 125 to 3200 A Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

NR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition

NR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

Miniatur Circuite Breakers (MCB)

Miniatur Circuite Breakers (MCB) Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage

More information

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T

More information

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase

More information

Catalog Number. Catalog Number

Catalog Number. Catalog Number ircuit reakers I-LIN Panelboards and Switchboards lass, 734, 8 I3 2- and 3-Pole 4.5 in (114 mm) Mounting Height Q2, Q2-H 2- and 3-Pole 3 in (7 mm) and 4.5 in (114 mm) Mounting Height rame, Thermal-Magnetic

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Installation Contactors ISU-xxx ISM-xxx

Installation Contactors ISU-xxx ISM-xxx Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals

More information

HYUNDAI U-Series Magnetic Contactor Overload Relay

HYUNDAI U-Series Magnetic Contactor Overload Relay Head Office www.hyundaielec.com, Jeonhadong, Donggu, Ulsan, Korea Tel: 0~ Fax: 00 Seoul 0, Gyedong, Jongnogu, Seoul, Korea (Sales & Marketing) Tel:, Fax: Orlando New Jersey Chicago London Tokyo Osaka Riyadh

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 6,9 grb 7 PA 6,9 grb 73 TTF 000 + MS7V-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

TEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation

TEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation age 1 of 92 R e port ref. No.: C009-CB2012CQC-044407 Test Report issued under the responsibility of: TEST REORT IEC 60 898-1:2002 Circuit-Breakers for overcorrect protection for household and similar installation

More information

THREE PHASE CAPACITOR For WIND TURBINES

THREE PHASE CAPACITOR For WIND TURBINES RS/Cond 28.04.2003 Pg: 1 / 3 THREE PHASE CAPACITOR For WIND TURBINES Applications: Three-phase capacitor for Wind Turbine has been designed for power factor correction in high harmonic current content.

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations Test Report issued under the responsibility of: TEST REORT IEC/EN 60898-1 Circuit-breakers for over current protection for household and similar installations Report Reference No.... : 130100913SHA-004

More information

Cat. No. 140M-F M-D8E-B

Cat. No. 140M-F M-D8E-B Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

440V 500V V / / /2 12.

440V 500V V / / /2 12. -26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective

More information

Rotary Switches AC09, 16 and 32

Rotary Switches AC09, 16 and 32 09, 16 and 32 igital code output type escription FUJI series rotary switches offer a wide choice of output codes. They feature sliding u-flashed contacts for high contact reliability. Inhibitor and parity

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

TeSys contactors. TeSys D contactors. 690 V on a and c

TeSys contactors. TeSys D contactors. 690 V on a and c Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V

More information

General characteristics

General characteristics General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and

More information

Redline. Line protection by means of MCB s. Protection against overloads. Circuit Protection T1.2

Redline. Line protection by means of MCB s. Protection against overloads. Circuit Protection T1.2 Redline Circuit Protection Line protection by means of MCB s Protective devices shall be capable of breaking any overcurrent up to and including the prospective shortcircuit current at the point where

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Moulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type

Moulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type TPact Moulded Case Circuit Breakers TPact Moulded Case Circuit Breaker. General Certificates: KEMA,CB; Electric ratings: AC0/0Hz, AC0V~90V DC0V~00V, A~0A; Standard: IEC/EN 097.. Type Designation TPact...

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link

More information

XM1 Motor Protection Relay. Manual XM1 (Revision B)

XM1 Motor Protection Relay. Manual XM1 (Revision B) XM1 Motor Protection Relay Manual XM1 (Revision B) Woodward Manual XM1 GB Woodward Kempen GmbH reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses BS88 Fuses x1, 17x9, X17x9, 6 VAC EXTREMELY HIGH BREAKING CAPACITY FUSES: PROTECTION OF POWER SEMICONDUCTORS AS PER IEC STANDARD 6069.1 AND 6 V VOLTAGE RATING COMPLYING WITH IEC GR CLASS (RATINGS FROM

More information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

DATA SHEET: TEMPOWER2 ACB

DATA SHEET: TEMPOWER2 ACB Electrical haracteristics to IE 097, IE 097 Type Series AMERE RATING(A) AR0SB Standard RATED URRENT (max) [I n ](A) JIS,IE, EN, AS NEMA, ANSI Marine NEUTRAL OLE AMERES FRAME (A) NUMBER OF OLES 3 RATED

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B FEATURES Non inductive High pulse loading capability. APPLICATIONS Application for overload and high voltage surge hazard circuits. DESCRIPTION A carbon film is deposited on a high grade ceramic body.

More information

MOULDED CASE CIRCUIT BREAKERS BL1000S

MOULDED CASE CIRCUIT BREAKERS BL1000S G MOUDED CASE CRCUT BREAKERS BS G BS COMMERCA NFORMATON P Switching units, withdrawable device, plug-in device...g Overcurrent releases...g Signalling units...g Connecting sets...h Switches...H Shunt trips...h

More information

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

R.46. X2 CLASS (IEC ) - MKP Series SELF-HEALING PROPERTIES 09/

R.46. X2 CLASS (IEC ) - MKP Series SELF-HEALING PROPERTIES 09/ Loose Taped X CLASS (IEC 60384-4) - MKP Series Typical applications: interference suppression and «across-the-line» applications. Suitable for use in situations where failure of the capacitor would not

More information

Microprocessor Based Characteristics and adjustments

Microprocessor Based Characteristics and adjustments Microprocessor Based Characteristics and adjustments 7- Range Operation Settings Operation and Examples 0 Ground Fault and Pre-rip larm LED ndication and OCR Controller ime/current Curves - OCR Checker

More information

DC motors. 1. Parallel (shunt) excited DC motor

DC motors. 1. Parallel (shunt) excited DC motor DC motors 1. Parallel (shunt) excited DC motor A shunt excited DC motor s terminal voltage is 500 V. The armature resistance is 0,5 Ω, field resistance is 250 Ω. On a certain load it takes 20 A current

More information

Products for Luminaire Protection and Power Adjustment Products

Products for Luminaire Protection and Power Adjustment Products Products for uminaire Protection and Power Adjustment Products uminaire Protection evice For electronic devices When electronic components form part of lighting systems, it is often necessary to protect

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components FEATURES Excellent anti-surge characteristics Stable characteristics to moisture resistance even in high resistance range. Good replacement for ceramic plate resistors. APPLICATIONS Telecommunication Industrial

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

Test Report issued under the responsibility of: SHA-001 Date of issue... : Total number of pages... : 292. Report Number...

Test Report issued under the responsibility of: SHA-001 Date of issue... : Total number of pages... : 292. Report Number... D Test Report issued under the responsibility of: TEST REORT Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General rules

More information

Non-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21

Non-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21 s e r i e s c3controls offers the most rugged, dependable Disconnect Switches that money can buy. From Panel/Base Mount to Door Mount with switch ratings from 16A - 125A, we ve got what you need. And,

More information

Circuits. PHY2054: Chapter 18 1

Circuits. PHY2054: Chapter 18 1 Circuits PHY2054: Chapter 18 1 What You Already Know Microscopic nature of current Drift speed and current Ohm s law Resistivity Calculating resistance from resistivity Power in electric circuits PHY2054:

More information

Chapter 6: Efficiency and Heating. 9/18/2003 Electromechanical Dynamics 1

Chapter 6: Efficiency and Heating. 9/18/2003 Electromechanical Dynamics 1 Chapter 6: Efficiency and Heating 9/18/2003 Electromechanical Dynamics 1 Losses As a machine transforms energy from one form to another there is always a certain power loss the loss is expressed as heat,

More information