TeSys contactors. TeSys D contactors. 690 V on a and c

Size: px
Start display at page:

Download "TeSys contactors. TeSys D contactors. 690 V on a and c"

Transcription

1 Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V on a and c Number of poles or or or or Rated operational power in AC- Auxiliary contacts Thermal overload relays manual-auto compatible 0/0 V. kw kw kw. kw. kw kw 0/00 V kw. kw. kw kw kw. kw /0 V kw. kw kw kw kw. kw 00 V. kw. kw 0 kw kw. kw. kw 0/0 V. kw. kw 0 kw kw. kw. kw 000 V N/C and N/O instantaneous incorporated in the contactors, with add-on blocks common to the whole range comprising up to N/C or N/O instantaneous, up to N/O + N/C time delay and up to N/O or N/C protected contacts and screen continuity terminals. Class 0 A A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A Class 0. 0 A. A. A. A Suppressor modules (c and low consumption contactors are fitted with a built-in bidirectional peak limiting diode suppressior as standard) Varistor p p p p p p Diode RC circuit p p p p p p Bidirectional peak limiting diode p p p p p p Interfaces Relay output p p p p p p Relay interface with p p p p p p manual override switch Contactor type references Reversing contactor type references a or c coils, pole LC D0 LC D LC D LC D LC D LC D a or c coils, pole LC DT0/ LC DT/ LC DT/ LC DT0/ LC D0 LC D LC D LC D a coils, pole LC D0 LC D LC D LC D LC D LC D c coils, pole LC D0 LC D LC D LC D LC D LC D a coils, pole LC DT0 LC DT LC DT LC DT0 c coils, pole LC DT0 LC DT LC DT LC DT0 Pages Contactors / to / Reversing contactors / to / 0 /

2 0 A 0 A A 0 A A A 0 A 0 A 0 A A 00 A 0 V a or c 000 V on a, 0 V on c kw kw. kw kw kw 0 kw 0 kw. kw kw 0 kw kw kw kw kw kw /0 kw kw kw kw kw 0 kw kw 0 kw kw kw kw kw 0 kw 0 kw kw kw kw kw 0 kw 00 kw kw kw kw 0 kw N/C and N/O instantaneous incorporated in the contactors, with add-on blocks common to the whole range comprising up to N/C or N/O instantaneous, up to N/O + N/C time delay and up to N/O or N/C protected contacts and screen continuity terminals. 0 A 0 A A 0 A 0 A 0 0 A 0 0 A 0 A 0 A A 0 A 0 0 A 0 0 A p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p p LC D0A LC D0A LC DA LC D0 LC D LC D LC D0 LC DT0A LC DT0A LC D0 LC D LC D0A LC D0A LC DA LC D0 LC D LC D LC D0 LC D0A LC D0A LC DA LC D0 LC D / to / / to / 0 /

3 Selection guide TeSys D low consumption contactors Applications Automation systems Rated operational current le max AC- (Ue y 0 V) A A A Rated operational voltage le AC- (q y 0 C) 0/ A 0/ A / A 0 V Number of poles or or or Rated operational power in AC- 0/0 V. kw kw kw 0/00 V kw. kw. kw /0 V kw. kw kw 00 V. kw. kw 0 kw 0/0 V. kw. kw 0 kw Coil consumption. W (00 ma - V) Operating ranges Operating time at 0 C and at Uc Closing Opening 0.. Uc 0 ms ms Auxiliary contact block modules Interference suppression N/C and N/O instantaneous contacts incorporated in the contactors, with add-on blocks common to the whole range, comprising up to N/C or N/O instantaneous standard contacts Built-in suppression as standard, by bi-directional peak limiting diode Contactor type -pole LC D0 LC D LC D -pole LC DT0/D0 LC DT/D LC DT/D Reversing contactor type -pole LC D0 LC D LC D -pole LC DT0 LC DT LC DT Pages Contactors / to / Reversing contactors / to / 0 () With low consumption kit LA DBL (see page /). () With low consumption kits LA DBL (see page /). /

4 A A A 0 A 0 A A /0 A 0 A 0 A 0 A 0 A 0 V 0 V or. kw. kw kw kw kw. kw kw kw. kw. kw kw 0 kw kw kw. kw kw /0 kw kw kw. kw. kw kw 0 kw kw kw. kw. kw 0 kw kw kw. W (00 ma - V) 0. W ( ma - V) for relay LA DFB + the power consumed by the contactor coil 0.. Uc 0 ms ms N/C and N/O instantaneous contacts incorporated in the contactors, with add-on blocks common to the whole range, comprising up to N/C or N/O instantaneous standard contacts Built-in suppression as standard, by bi-directional peak limiting diode LC D LC D LC D LC D0A () LC D0A () LC DA () LC DT0/D LC D LC D LC D LC D0A () LC D0A () LC DA () LC DT0 / to / / to / 0 /

5 Characteristics TeSys D contactors Contactor type LC D0 D DT0 and DT Environment Rated insulation voltage (Ui) Conforming to IEC 0--, overvoltage category III, degree of pollution: Conforming to UL, CSA V 00 Rated impulse withstand voltage (Uimp) Conforming to standards D D DT and DT0 D0A DA DT0A and DT0A V Conforming to IEC 0 kv D0 D IEC/EN 0--, IEC/EN 0--, UL 0, CSA C. n. D and D0 Product certifications Degree of protection () (front face only) Conforming to VDE 00 and IEC 0 Power circuit connections UL, CSA (), CCC, GOST GL, DNV, RINA, BV, LROS (LROS pending for contactors LC D0A to DA) Protection against direct fi nger contact IP X Coil connection Protection against direct fi nger contact IP X Protective treatment Conforming to IEC TH Ambient air temperature around the device Storage C Operation C Permissible C , for operation at Uc Maximum operating altitude Without derating m 000 Operating positions () Without derating in the following positions a/c a c Positions that are not permissible For c contactors LC D0 to LC DA. Flame resistance Conforming to UL V Shock resistance () / sine wave = ms Conforming to IEC 0-- C 0 Contactor open 0 gn gn 0 gn gn gn Contactor closed gn gn gn 0 gn gn Vibration resistance () 00 Hz Contactor open gn Contactor closed gn gn gn gn gn () Contactor LC D with d.c. coil is not UL/CSA certifi ed. () Protection provided for the cabling c.s.a.'s indicated on the next page and for connection by cable. () When mounting on a vertical rail, use a stop. () Without modifying the contact states, in the most unfavourable direction (coil energised at Ue). 0 /0

6 Characteristics (continued) TeSys D contactors Contactor type LC D0 and D DT0 and DT D (P) Power circuit connections Screw clamp terminal connections D (P) D D D and D (P) DT and DT0 Tightening Screw clamp terminals Connector inputs Flexible cable without cable end Flexible cable with cable end Solid cable without cable end D0A to DA DT0A and DT0A () Screw clamp terminals D0 and D Connector input D and D0 Connector inputs conductor mm conductors mm and conductor mm conductors mm... 0 and conductor mm conductors mm.. 0. and Screwdriver Philips N N N N Flat screwdriver Ø Ø Ø Ø Ø Ø Ø Hexagonal key Tightening torque N.m.... : y mm : mm Spring terminal connections () Flexible cable without cable end conductor mm. (: DT) conductors mm. (except DT) 0 Connection by bars or lugs Bar c.s.a. x x Lug external Ø mm 0 0. Ø of screw mm M. M. M M M. M M M Screwdriver Philips N N N N N Flat screwdriver Ø Ø Ø Ø Ø Ø Ø Key for hexagonal headed screw 0 0 Tightening torque N.m..... Control circuit connections Connection by cable (tightening via screw clamps) Flexible cable conductor mm. without cable end conductors mm. Flexible cable conductor mm.. with cable end conductors mm Solid cable conductor mm. without cable end conductors mm. Screwdriver Philips N N N N N N N N Flat screwdriver Ø Ø Ø Ø Ø Ø Ø Ø Ø Tightening torque N.m Spring terminal connections () Flexible cable conductor mm without cable end conductors mm Connection by bars or lugs Lug external Ø mm Ø of screw mm M. M. M. M. M. M. M. M. Screwdriver Philips N N N N N N N N Flat screwdriver Ø Ø Ø Ø Ø Ø Ø Ø Ø Tightening torque N.m () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () If cable ends are used, choose the next size down (example: for. mm, use. mm ) and square crimp the cable ends using a special tool. 0 /

7 Characteristics (continued) TeSys D contactors Contactor type LC D0 (P) Pole characteristics Rated operational current (Ie) (Ue y 0 V) In AC-, q y 0 C A In AC-, q y 0 C A () 0 () () 0 () 0 Rated operational voltage (Ue) Up to V Frequency limits Of the operational current Hz Conventional thermal current (Ith) q y 0 C A () 0 () () 0 () 0 Rated making capacity (0 V) Conforming to IEC 0 A Rated breaking capacity (0 V) Conforming to IEC 0 A Permissible short time rating For s A No current flowing for preceding For 0 s A minutes with q y 0 C For min A 0 For 0 min A Fuse protection Without thermal type A 0 0 against short-circuits overload relay, (U y 0 V) gg fuse type A 0 0 With thermal overload relay A See pages /0 and /, for am or gg fuse ratings corresponding to the associated thermal overload relay Average impedance per pole At Ith and 0 Hz mw... Power dissipation per pole for AC- W the above operational currents AC- W.... Control circuit characteristics, a.c. supply Rated control circuit voltage (Uc) 0/0 Hz V 0 Control voltage limits 0 or 0 Hz coils Operation Drop-out 0/0 Hz coils Operation 0.. Uc on 0 Hz and 0.. Uc on 0 Hz at 0 C DT0 D0 Drop-out Uc at 0 C Average consumption a 0 Hz Inrush 0 Hz coil VA at 0 C and at Uc Cos j 0. 0/0 Hz coil VA 0 Sealed 0 Hz coil VA Cos j 0. 0/0 Hz coil VA a 0 Hz Inrush 0 Hz coil VA Cos j 0. 0/0 Hz coil VA 0 Sealed 0 Hz coil VA Cos j 0. 0/0 Hz coil VA. Heat dissipation 0/0 Hz W Operating time Closing "C" ms () Opening "O" ms Mechanical durability 0 or 0 Hz coil in millions of operating cycles 0/0 Hz coil on 0 Hz D (P) DT D D (P) DT D D (P) DT0 D Maximum operating rate at ambient temperature y 0 C In operating cycles per hour 00 () Versions with spring terminal connections: A for LC D0 and LC D (0 A possible with x. mm in parallel), A for LC D to LC D ( A possible for LC D connected with x mm cables in parallel; 0 A possible for LC D and LC D connected with x mm in parallel). () The closing time "C" is measured from the moment the coil supply is switched on to closure of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. 0 Selection : pages / to / References: pages / to / Dimensions: pages / to / Schemes: pages / and / /

8 D D D0A DT0A D0A DA DT0A D0 D D D () See pages /0 and / for am or gg fuse ratings corresponding to the associated thermal overload relay Uc at C Uc at C Uc at C 0.. Uc on 0 Hz and 0.. Uc on 0 Hz at 0 C 0.. Uc on 0 Hz and 0.. Uc on 0 Hz at 0 C 0.. Uc on 0 Hz and 0.. Uc on 0 Hz at C 0.. Uc on 0/0 Hz at C Uc at 0 C Uc at 0 C Uc at C Uc at C /

9 Characteristics (continued) TeSys D contactors Contactor type d.c. control circuit characteristics Rated control circuit voltage (Uc) LC D0 D LC DT0 DT0 LC D0A DA LC DT0A and DT0A LC or LP D0 LC D LC D and LC D0 c V Rated insulation voltage Conforming to IEC 0- V 0 Conforming to UL, CSA V 00 Control voltage limits Operation Standard coil Wide range coil Drop-out Average consumption at 0 C and at Uc 0.. Uc at 0 C 0.. Uc at 0 C 0.. Uc at C 0.. Uc at C Uc at 0 C Uc at 0 C Uc at C 0.. Uc at C Uc at C c Inrush W. 0 Sealed W.... Operating time () Closing "C" ms ± % 0 ± % 0 0 average at Uc Opening O ms 0 ± 0 % 0 ± 0% 0 0 Note: The arcing time depends on the circuit switched by the poles. For all normal -phase applications, the arcing time is less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Time constant (L/R) ms Mechanical durability at Uc In millions of operating cycles Maximum operating rate In operating cycles per hour at ambient temperature y 0 C Low consumption control circuit characteristics Rated insulation voltage Conforming to IEC 0- V 0 Conforming to UL, CSA V 00 Maximum voltage Of the control circuit on c V 0 Average consumption d.c. at 0 C and at Uc Operating time () at Uc and at 0 C Wide range coil (0.. Uc) Inrush W. Sealed W. Closing "C" ms ± % Opening O ms ± 0 % Voltage limits (q y 0 C) of the control circuit Operation 0. to. Uc Drop-out Uc Time constant (L/R) ms 0 Mechanical durability In millions of operating cycles 0 Maximum operating rate In operating cycles per hour 00 at ambient temperature y 0 C () The operating times depend on the type of contactor electromagnet and its control mode. The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate 0 Selection : pages / to / References: pages / to / Dimensions: pages / to / Schemes: pages / and / /

10 Characteristics (continued) TeSys D contactors Characteristics of auxiliary contacts incorporated in the contactor Mechanically linked contacts Conforming to IEC 0-- Each contactor has N/O and N/C contacts mechanically linked on the same movable contact holder Mirror contact Conforming to IEC 0-- The N/C contact on each contactor represents the state of the power contacts and can be connected to a PREVENTA safety module Rated operational voltage Up to V 0 (Ue) Rated insulation voltage Conforming to IEC 0- V 0 (Ui) Conforming to UL, CSA V 00 Conventional thermal current (Ith) For ambient temperature y 0 C A 0 Frequency of the operational current Hz 00 Minimum switching U min V capacity l = 0 I min ma Short-circuit protection Conforming to IEC 0-- gg fuse: 0 A Rated making capacity Conforming to IEC 0--, I rms A a: 0, c: 0 Short-time rating Permissible for s A ms A 0 00 ms A 0 Insulation resistance MW > 0 Non-overlap time Guaranteed between N/C and N/O contacts Operational power of contacts conforming to IEC 0-- ms. (on energisation and on de-energisation) a.c. supply, categories AC- and AC- Electrical durability (valid for up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making current (cos j 0.) = 0 times the power broken (cos j 0.). d.c. supply, category DC- Electrical durability (valid for up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V V 0 0 million operating cycles VA W million operating cycles VA W 0 million operating cycles VA W AC- DC- Millions of oprating cycles 0 0, 0, 0, 0, 0, Millions of oprating cycles 0 0, 0, 0, 0, 0, 0 V V V V 0 V 0, 0, 0, 0, 0, 0, 0, 0, 0 Current broken in A 0, 0, 0, 0, 0, 0, 0, 0, 0 Current broken in A 0 Selection : pages / to / References: pages / to / Dimensions: pages / to / Schemes: pages / and / /

11 Characteristics Auxiliary contact blocks without dust and damp protected contacts for TeSys D contactors Contact block type LAD N or LAD C LAD T and LAD S LAD R LAD Environment Conforming to standards IEC 0--, NF C -0, VDE 00, BS, EN 0-- Product certifications UL, CSA Protective treatment Conforming to IEC 00 TH Degree of protection Conforming to VDE 00 Protection against direct finger contact IP X Ambient air temperature Storage C around the device Operation C Permissible for operation at Uc C Maximum operating altitude Without derating m 000 Connection by cable Phillips N and Ø mm mm Min: x ; max: x. Flexible or solid cable with or without cable end Spring terminal connections Flexible or solid cable without cable end mm Max: x. Instantaneous and time delay contact characteristics Number of contacts, or Rated operational voltage (Ue) Rated insulation voltage (Ui) Up to V 0 Conforming to IEC 0-- V 0 Conforming to UL, CSA V 00 Conventional thermal current (Ith) For ambient temperature y 0 C A 0 Frequency of the operational current Hz 00 Minimum switching capacity U min V I min ma Short-circuit protection Conforming to IEC 0-- and VDE 00. gg fuse A 0 Rated making capacity Conforming to I rms A a: 0; c: 0 IEC 0-- Short-time rating Permissible for s A ms A 0 00 ms A 0 Insulation resistance MW > 0 Non-overlap time Overlap time Time delay (LADT, R and S contact blocks) Accuracy only valid for setting range indicated on the front face Guaranteed between N/C and N/O contacts ms. (on energisation and on de-energisation) Guaranteed between N/C and ms. N/O contacts on LAD C Ambient air temperature C for operation Repeat accuracy ± % ± % Drift up to 0. million + % + % operating cycles Drift depending on 0. % per C 0. % per C ambient air temperature Mechanical durability In millions of operating cycles 0 0 Operational power See page / of contacts 0 References : pages / and /0 / Dimensions : pages / and / Schemes : pages / and /

12 Characteristics (continued) Auxiliary contact blocks with dust and damp protected contacts for TeSys D contactors Contact block type LA DX LA DZ LA DY Protected Environment Conforming to standards IEC 0--, VDE 00 Non protected Product certifications UL, CSA Protective treatment Conforming to IEC 00 TH Degree of protection Conforming to VDE 00 Protection against direct finger contact IP X Ambient air temperature Storage and operation C Cabling Phillips N and Ø mm Flexible or solid conductor with or without cable end mm Min: x ; max: x. Number of contacts Contact characteristics Rated operational voltage (Ue) Rated insulation voltage (Ui) Conventional thermal current (Ith) Up to V Conforming to IEC 0-- V Conforming to UL, CSA V 00 For ambient temperature y 0 C A 0 Maximum operational current ma (Ie) Frequency of the operational current Hz 00 Minimum switching capacity U min V I min ma Short-circuit protection Conforming to IEC 0- gg fuse A 0 Rated making capacity Conforming to I rms A a:0; c: 0 IEC 0- Short-time rating Permissible for s A ms A 0 00 ms A 0 Insulation resistance MW > 0 > 0 > 0 > 0 Mechanical durability In millions of operating cycles 0 Materials and technology used for dust and damp protected contacts Silver - Single break Silver - Single break Gold - Single break with crossed bars 0 References : pages / and /0 Dimensions : pages / and / Schemes : pages / and / /

13 Characteristics (continued) Auxiliary contact blocks with dust and damp protected contacts for TeSys D contactors Rated operational power of contacts (conforming to IEC 0--) a.c. supply, categories AC- and AC- Electrical durability (valid for up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making current (cos j 0.) = 0 times the power broken (cos j 0.). V million operating cycles VA million operating cycles VA million operating cycles VA Millions of oprating cycles 0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 Current broken in A d.c. supply, category DC- Electrical durability (valid for up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 0 0 million operating cycles W 0 0 million operating cycles W million operating cycles W 0 Millions of operating cycles 0 0 V V V V 0, 0, 0, 0, 0, 0, 0, 0 V 0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 Current broken in A References : pages / and /0 / Dimensions : pages / and / Schemes : pages / and /

14 Characteristics Control modules, coil suppressor modules and mechanical latch blocks for TeSys D contactors Environment Conforming to standards IEC 0-- Product certifications UL, CSA Protective treatment Conforming to IEC 00 TH Degree of protection Conforming to VDE 00 Protection against direct finger contact IP X Ambient air temperature around the device Suppressor modules Module type Storage C Operation C + Permissible for operation at Uc C + 0 LA DA, LAD RC, LAD RC LA DB, LAD T, LAD T Type of protection RC circuit Bidirectional peak limiting diode LA DC, LAD D LA DE, LAD V, LAD V Diode Varistor Rated control circuit voltage (Uc) V a a or c 0 c 0 a or c 0 Maximum peak voltage Uc Uc Uc Uc Natural RC frequency / V Hz 00 0/ V Hz 00 0/0 V Hz 00 0/ V Hz 0 Mechanical latch blocks () Mechanical latch block type LAD K0 LA DK0 For use on contactor LC D0 DA DT0 DT0A Product certifications UL, CSA UL, CSA Rated insulation voltage Conforming to IEC 0-- V 0 0 Rated control circuit voltage a 0/0 Hz and c V Power required For unlatching a VA c W 0 0 Maximum operating rate In operating cycles/hour LC D0 D0 LP D0 and LC D On-load factor 0 % 0 % Mechanical durability at Uc In millions of operating cycles () Unlatching can be manually operated or electrically controlled (pulsed). The LA DK or LAD K latch coil and the LC D operating coil must not be energised simultaneously. The duration of the LA DK or LAD K and LC D control signals must be u 00 ms. 0 References : pages / and /0 Dimensions : pages / and / Schemes : pages / and / /

15 Characteristics Electronic serial timer module for TeSys D contactors Module type LA DT (On-delay) Environment Conforming to standards IEC 0- Product certifications UL, CSA Protective treatment Conforming to IEC 00 TH Degree of protection Conforming to VDE 00 Protection against direct finger contact IP X Ambient air temperature around the device Storage C Operation C + For operation at Uc C + 0 Rated insulation voltage (Ui) Conforming to IEC 0- V 0 Cabling Phillips n and Ø mm Flexible or solid conductor with or without cable end mm Min: x ; max: x. Control circuit characteristics Built-in protection Of the input By varistor Contactor coil suppression By varistor Rated control circuit voltage (Uc) V a or c : 0 Permissible variation 0.. Uc Type of control By mechanical contact only Timing characteristics Timing ranges s 0. ;. 0; 00 Repeat accuracy 0 0 C ± % (0 ms minimum) Reset time During time delay period ms 0 After time delay period ms 0 Immunity to microbreaks During time delay period ms 0 After time delay period ms Minimum control pulse duration ms Time delay signalling By LED Illuminates during time delay period Switching characteristics (solid state type) Maximum power dissipated W Leakage current ma < Residual voltage V. Overvoltage protection Electrical durability In millions of operating cycles 0 Function diagram Electronic on-delay timer LA DT kv; 0. joule U supply (A-A) 0 Time delay output Contactor coil 0 Red LED t 0 References : pages / /0 Dimensions : pages / and / Schemes : pages / and /

16 Characteristics Interface modules for TeSys D contactors Environment Conforming to standards IEC 0- Product certifications UL, CSA Protective treatment Conforming to IEC 00 TH Degree of protection Conforming to VDE 00 Protection against direct finger contact IP X Ambient air temperature around the device Other characteristics Module type Storage C Operation C + Permissible for operation at Uc C + 0 Conventional thermal For ambient temperature y 0 C A current (Ith) Rated insulation voltage Conforming to IEC 0-- V 0 Rated operational voltage Conforming to IEC 0-- V 0 LA DFB With relay LA DWB Solid state Indication of input state By integral LED which illuminates when the contactor coil is energised Input signals Control voltage (E-E) V c c Permissible variation V 0 0 Current consumption at 0 C ma. for V for V State 0 guaranteed for U V <. <. I ma < < State guaranteed for U V Built-in protection Against reversed polarity By diode By diode Of the input By diode By diode Electrical durability at 0 A/0 V In millions of operating cycles 0 0 Maximum immunity to microbreaks ms Power dissipated At 0 C W Direct mounting on contactor With coil a 0 V LC D0 D0 a 00 0 V LC D0 D a 0 V Mounting with cabling adapter LAD BB With coil a 0 V LC D0 D, LC DT0 DT0 a 0 V LC D0 D, LC DT0 DT0 Mounting with cabling adapter LAD BB Total operating time at Uc (of the contactor) With coil a 0 V LC D0A DA LC D0A DA a 0 V LC D0A DA LC D0A DA The operating times depend on the type of contactor electromagnet and its control mode. The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. LC D0 D, LC D0A DA LC D0 and D LC DT0 DT0 With LA DFB "C" ms 0 0 O ms 0 Cabling Phillips N and Ø mm Flexible or solid cable with or without cable end mm Min: x ; max: x. 0 References : pages / Dimensions : pages / and / Schemes : pages / and / /

17 References TeSys D contactors for motor control up to kw at 00 V, in category AC- For connection by screw clamp terminals and lugs LC D0pp LC Dpp -pole contactors Standard power ratings of -phase motors 0-0 Hz in category AC- (q y 0 C) 0 V 0 V V 0 V 00 V 0 V 000 V 0 V 00 V 0 V Rated operational current in AC- 0 V up to Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code () Fixing () Weight () kw kw kw kw kw kw kw A kg Connection by screw clamp terminals... LC D0pp LC Dpp LC Dpp 0.0. LC Dpp LC Dpp LC Dpp 0.0 Power connections by EverLink BTR screw connectors () and control by spring terminals. 0 0 LC D0App () LC D0App () LC DApp () 0.0 Connection by screw clamp terminals or connectors 0 LC D0pp.0 LC Dpp LC Dpp LC D0pp.00 Connection by lugs or bars In the references selected above, insert a fi gure before the voltage code. Example: LC D0pp becomes LC D0pp. Separate components Auxiliary contact blocks and add-on modules: see pages / to /. LC DApp () LC D0 to DA: clip-on mounting on mm rail AM DP or screw fi xing. LC D0 to D a: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fi xing. LC D0 to D c : clip-on mounting on mm rail AM DL or screw fi xing. LC D and D0: clip-on mounting on x mm rails AM DP or screw fi xing. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0 D0 (D and D0 coils with built-in suppression as standard, by bi-directional peak limiting diode). 0/0 Hz B D E F FE M P U Q V N R S LC D0 D 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c. supply Volts LC D0 DA (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD LC D0 D U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.. Uc JW BW CW EW SW FW MW LC D and D0 (coils with integral suppression device fi tted as standard) U 0.. Uc BD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D, 0.0 kg from LC D0A to DA and kg for LC D0 and D. () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () For low consumption kit LA DBL (see page /). 0 LC Dpp 0 LC Dpp Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

18 References TeSys D contactors for motor control up to 0 kw at 00 V, in category AC- For connection by spring terminals -pole contactors Standard power ratings of -phase motors 0-0 Hz in category AC- (q y 0 C) 0 V 0 V V 0 V 00 V 0 V 000 V 0 V 00 V 0 V Rated operational current in AC- 0 V up to Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code () Fixing () Weight () LC Dpp kw kw kw kw kw kw kw A kg Power and control connections by spring terminals... LC D0pp LC Dpp LC Dpp 0.0. LC Dpp () LC Dpp 0. Power connections by EverLink BTR screw connectors () and control by spring terminals. 0 0 LC D0App () LC D0App () LC DApp () 0.0 Connection by Faston connectors These contactors are fi tted with Faston connectors: x. mm on the power poles and x. mm on the coil and auxiliary terminals. For contactors LC D0 and LC D only, replace the fi gure with a in the references selected above. Example: LC D0pp becomes LC D0pp. Separate components Auxiliary contact blocks and add-on modules: see pages / to /. LC DApp () LC D0 to D: clip-on mounting on mm rail AM DP or screw fi xing. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0 DA 0/0 Hz B D E F FE M P U Q V N R d.c. supply Volts LC D0 DA (coils with built-in suppression as standard, by bi-directional peak limiting diode) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D and 0.0 kg from LC D0A to DA. () Must be wired with x mm cables in parallel on the upstream side. On the downstream side, outgoing terminal block LAD may be used (Quickfi t technology, see page /). When wired with a single cable, the product is limited to A ( kw/00 V motors). () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () For low consumption kit LA DBL (see page /). 0 Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

19 References TeSys D, -pole contactors for control in category AC-, from to 00 A 0 -pole contactors Non inductive loads maximum current (q y 0 C) utilisation category AC- Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code () Fixing () Weight () LC D0pp A kg Connection by screw clamp terminals LC D0pp 0.0 or LC Dpp 0. LC Dpp LC Dpp LC Dpp 0. or LC Dpp 0.0 Connection by EverLink, BTR screw connectors () 0 LC D0App () LC D0App () 0. or LC DApp () () 0.0 Connection by screw clamp terminals or connectors LC D0pp.0 or LC Dpp ().0 00 LC Dpp.00 or LC D0pp ().00 -pole contactors for connection by lugs In the references selected above, insert a fi gure before the voltage code. Example: LC D0pp becomes LC D0pp. 0 LC DApp () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0...D0 (coils D and D0 fi tted with integral suppression device as standard) 0/0 Hz B D E F FE M P U Q V N R LC D0...D0 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c. supply Volts LC D0...DA (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD LC or LP D0 and D U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.. Uc JW BW CW EW SW FW MW LC D and D0 (coils with integral suppression device fi tted as standard) U 0.. Uc BD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () LC D0 to DA: clip-on mounting on mm rail AM DP or screw fi xing. LC D0 and D a: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fi xing. LC or LP D0 to D c: clip-on mounting on mm rail AM DL or screw fi xing. LC D and D0: clip-on mounting on x mm rails AM DP or screw fi xing. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D, 0.0 kg from LC D0A to DA and kg for LC D0 and D. () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () Selection according to the number of operating cycles, see AC- curve, page /. () A with x mm cables connected in parallel. () For low consumption kit LA DBL (see page /). Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

20 References (continued) TeSys D, -pole contactors For control in category AC-, to 00 A -pole contactors for connection by Faston connectors These contactors are fi tted with Faston connectors: x. mm on the power poles and x. mm on the coil terminals. For contactors LC D0 and LC D only, in the references selected from the previous page, insert a fi gure before the voltage code. Example: LC D0pp becomes LC D0pp. -pole contactors Non inductive loads maximum current (q y 0 C) utilisation category AC- Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code () Fixing () Weight () LC Dpp A kg Connection by spring terminals LC D0pp () 0.0 or LC Dpp () 0. LC Dpp () 0. or LC Dpp () 0. or LC Dpp () 0. Power connections by EverLink BTR screw connectors () and control by spring terminals 0 LC D0App () LC D0App () () 0. or LC DApp () () 0.0 LC DApp Separate components Auxiliary contact blocks and add-on modules: see pages / to /. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0...DA 0/0 Hz B D E F FE M P U Q V N R S d.c. supply Volts LC D0...DA (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () LC D0 to DA: clip-on mounting on mm rail AM DP or screw fi xing. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D and 0.0 kg from LC D0A to DA. () 0 A with x. mm cables connected in parallel. () A with x mm cables connected in parallel. () 0 A with x mm cables connected in parallel. () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () Selection according to the number of operating cycles, see AC- curve, page /. () For low consumption kit LA DBL (see page /). 0 Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

21 References (continued) TeSys D, -pole contactors For control in category AC-, to 00 A -pole contactors for connection by screw clamp terminals or connectors Non inductive loads maximum current (q y 0 C) utilisation category AC- Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the control voltage code () Fixing () Weight () LC DT0pp LC DT0App A kg Connection by screw clamp terminals 0 LC DT0pp 0. LC D0pp 0. LC DTpp 0. LC Dpp 0. LC DTpp 0. LC Dpp 0. 0 LC DT0pp 0. LC Dpp 0. Connection by EverLink, BTR screw connectors 0 LC DT0App.00 0 LC DT0App.0 Connection by screw clamp terminals or connectors 0 LC D000pp.0 or LP D000pp.0 0 LC D00pp.0 or LP D00pp.0 LC D000pp.0 or LP D000pp. LC D000pp.0 or LP D000pp.0 00 LC D00pp.0 0 LC D00pp -pole contactors for connection by lugs or bars In the references selected above, insert a fi gure before the voltage code. Example: LC DT0pp becomes LC DT0pp. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0...D0 and LC DT0...DT0A (coils D and D0 fi tted with integral suppression device as standard) 0/0 Hz B D E F FE M P U Q V N R LC D0...D 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c. supply Volts LC D0...DA and LC DT0...DT0A (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD LC or LP D0 U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.. Uc JW BW CW EW SW FW MW LC D (coils with integral suppression device fi tted as standard) U 0.. Uc BD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D and LC DT0...DT0 (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () LC D0 to D and LC DT0 to DT0A: clip-on mounting on mm rail AM DP or screw fi xing. LC D0 a: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fi xing. LC or LP D0 c: clip-on mounting on mm rail AM DL or screw fi xing. LC D and D0: clip-on mounting on x mm rails AM DP or screw fi xing. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D, 0.0 kg from LC DT0A and D0A and kg for LC D0. Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

22 References (continued) TeSys D, -pole contactors For control in category AC-, to 00 A -pole contactors Non inductive loads maximum current (q y 0 C) utilisation category AC- Number of poles Instantaneous auxiliary contacts Basic reference, to be completed by adding the voltage code () Fixing () Weight () A kg Connection by spring terminals 0 LC DT0pp 0.0 LC D0pp 0.0 LC DTpp 0.0 LC Dpp 0.0 LC DTpp 0. LC Dpp 0. 0 LC DT0pp 0. LC Dpp 0. Connection by by EverLink, BTR screw connectors and control circuit by spring terminals 0 LC DT0App.00 0 LC DT0App.0 Separate components Auxiliary contact blocks and add-on modules: see pages / to /. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0...D and LC DT0...DT0A (coils with integral suppression device fi tted as standard) 0/0 Hz B D E F FE M P U Q V N R d.c. supply Volts LC D0...D and LC DT0...DT0A (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D and LC DT0...DT0 (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () LC D0 to D and LC DT0 to DT0A: clip-on mounting on mm rail AMDP or screw fi xing. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg from LC D0 to D, 0.0 kg for LC DT0A and DT0A. 0 Selection : pages / to / Characteristics : pages /0 to / Dimensions : pages / to / Schemes : pages / and / /

23 Presentation for the North American market, conforming to UL and CSA M Motor Disconnect (Disconnect switch) Motor Branch Circuit Protection (Short-circuit protection) Motor Controller (Contactor) Motor Overload Protection (Thermal overload relay) Starters for the North American market In recent years, the North American market has started to harmonise UL, CSA and ANCE standards, as well as the industrial installation codes provided by national regulations (NEC for the United States, CEC for Canada and MEC for Mexico). () Major improvements, carried out by the Canena () are aimed at harmonising product requirements based on IEC () standards. However, the North American codes use specific terminology for defining the functions of a starter. These functions can be fulfilled by standard IEC products, accompanied by appropriate certifications. Combination Starters Combination Starters are the most common type of packaged motor starter. They are called "Combination" because of their structure and their combined functions. The figure opposite shows the four combined functions that constitute a complete motor starter circuit, defined as a Motor branch circuit by the NEC (US National Electric Code) in article 0. Standard UL0 currently gives different types of combination starter that meet the requirements of a "Motor branch circuit". Type E, called self-protected combination starter, covers all these functions and can be controlled manually (thermal-magnetic circuit-breaker) or remotely (starter-controller). Type E starters withstand faults within their declared nominal rating without sustaining damage, after which they can be put back into service. In addition, they can withstand more severe short-circuit and durability performance tests without welding or excessive wear of the contact tips. Type F, called Combination motor starter, consists of a type E manual starter (thermal-magnetic circuit-breaker) combined with a contactor. These starters are evaluated by means of basic short-circuit tests, but are not considered as self-protected. For this combination, the type E starter must be marked Combination Motor Controller when used with..., followed by the reference of the load side contactor. () UL: Underwriters Laboratories, CSA: Canadian Standards Association, ACNE: Association of Standardization and Certification, NEC: National Electric Code, CEC: Canadian Electrical Code, MEC: Mexican Electrical Code. () Canena: Council for Harmonization of Electrotechnical Standardization of North America. () IEC: International Electrotechnical Commission. 0 /

24 Presentation (continued) for the North American market, conforming to UL and CSA Control panels To help users properly coordinate their motor control equipment with their distribution system in the event of a fault, article 0 of the 00 NEC requires panel builders to list the short-circuit withstand rating of their motor control panels. According to standard UL0A, manufacturers must use the short-circuit withstand value of the lowest rated device as the nominal withstand rating of the panel, unless the devices have been tested together for a higher coordinated rating. The minimum short-circuit current rating (SCCR), on motor control components for horsepower ratings of 0 hp or below is 000 A. Using a type E or type F combination starter eliminates the coordination problems of using individual components for the motor branch circuit protection, motor controller and motor overload protection functions. The panel builder uses the declared short-circuit current rating for the combination starter. This value is generally higher than 000 A. This makes it easier to list the short-circuit current ratings and to check the compatibility of a UL0A motor control panel within a given distribution system. 0 /

25 Presentation (continued) for the North American market, conforming to UL and CSA Group protection Article 0. of the NEC allows a single short-circuit protection device to be used for more than one motor circuit if the components used are marked and listed for such use. Components suitable for use in group protection, known as motor group installations, can be marked in one of the following two ways: Case n The contactor and the motor overload relay are both listed as suitable for group installation. An inverse time circuit-breaker can be used as the short-circuit protection device if it is also listed as suitable for group installation. The panel builder must therefore make sure that the short-circuit protection device selected (fuses or inverse time circuit-breaker) does not exceed the value allowed by article 0.0 for the smallest overload relay used in the circuit. Once these conditions have been met, the panel builder can reduce the size of the conductor connecting the short-circuit protection device to the individual motor contactor/overload relay, to one third of the size of the upstream circuit conductor supplying the protection device. The panel builder must limit the length of the motor starter conductor (connecting the short-circuit protection device to the motor contactor/overload relay) to a maximum of. m ( feet). Case n The motor contactor and overload relay are listed as suitable for tap conductor protection in group installations. This category allows the panel designer to reduce the size of the conductor connecting the short-circuit protection device to the individual motor contactor/overload relay, to one tenth of the size of the upstream circuit conductor supplying the protection device. The designer must limit the length of this conductor to a maximum of.0 m (0 feet). In both cases, the supply circuits must not be less than % of the connected motor FLA (Full Load Amps) rating. For panel builders, using type F combination starters in group installations simplifies group motor considerations. Each starter is a fully coordinated motor branch circuit. The panel builder follows the same NEC requirements for sizing the supply conductors as those required for single motor branch circuits. The size of the supply conductors can be reduced in accordance with the specifications of article 0.. This allows the same flexibility in conductor sizing as that offered in article 0. (D), without a requirement to check the short-circuit protection rating marked on the components and the overload relay limit. A UL0A panel does not need a short-circuit protection device when each motor starter installed is a type F. The upstream short-circuit protection device supplying the starter protects the panel. The panel builder only has to consider the panel/enclosure disconnect requirements specified by the NEC or local codes. 0 /0

26 Reference for the North American market, conforming to UL and CSA standards, 0 to 00 LC D0pp Contactors Standard power ratings of motors 0/0 Hz Size Associated Continuous Single-phase -phase cable current Ø Ø type C-Cu V 0 V 0 V 00 V 0 V 0 V 0 V 0 V 0 V V 00 V Type of contactor required Basic reference, to be completed () Fixing, connection () HP HP HP HP HP HP A Connection by screw clamp terminals AWG0 0 LC D0pp. 0 0 AWG0 LC Dpp 0 0 AWG LC Dpp. 0 AWG 0 LC Dpp AWG 0 LC Dpp Power connections by EverLink BTR screw connectors () and control by spring terminals AWG 0 LC D0App. 0 0 AWG 0 LC D0App AWG 0 LC DApp LC Dpp Connection by screw clamp terminals or connectors AWG 0 LC D0pp AWG 0 LC Dpp AWG/0 LC Dpp AWG/0 00 LC D0pp 0 Applications with High-Fault Short-Circuit ratings For contactors LC D0A to LC DA, the High-Fault Short-Circuit ratings are 0 ka at 0 V and ka at 00 V. Application example For a HP-0 V motor Select a contactor type LC D0A. Information: the contactor rating selected corresponds to size, the associated cable is type AWG C-Cu. LC DApp LC Dpp () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): a.c. supply Volts LC D0 D0 (D and D0 coils with integral suppression device fitted as standard) 0/0 Hz B D E F FE M P U Q V N R S LC D0 D 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c. supply Volts LC D0 DA (coils with integral suppression device fitted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD LC D0 and D U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.. Uc JW BW CW EW SW FW MW LC D and D0 (coils with integral suppression device fitted as standard) U 0.. Uc BD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0 D (coils with integral suppression device fitted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL () LC D0 to DA: clip-on mounting on mm rail AM DP or screw fixing. LC D0 and LC D: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fixing. LC D and D0: clip-on mounting on x mm rails AM DP or screw fixing. 0 /

27 References TeSys D, -pole reversing contactors for motor control up to kw at 00 V, in category AC- Horizontally mounted, pre-assembled LC Dpp -pole reversing contactors for connection by screw clamp terminals Pre-wired power connections. Standard power ratings of -phase motors 0-0 Hz in category AC- (q y 0 C) 0 V 0 V V 0 V 00 V 0 V 0 V 00 V 0 V 000 V Rated operational current in AC- 0 V up to Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the control voltage code () Fixing () Weight () kw kw kw kw kw kw kw A kg With mechanical interlock, without electrical interlocking, for connection by screw clamp terminals or connectors... LC D0pp () LC Dpp () LC Dpp () 0.0. LC Dpp () LC Dpp () LC Dpp () LC D0App () LC D0App ().0. 0 LC DApp ().0 0 LC D0pp.00 LC Dpp.00 LC DApp With mechanical interlock and electrical interlocking, for connection by screw clamp terminals or connectors 0 0 LC Dpp LC D0pp.00 LC Dpp Connection by lugs or bars For reversing contactors LC D0 to LC D, LC D and LC D0, in the references selected above, insert a fi gure before the voltage code. Example: LC D0pp becomes LC D0pp. To build a 0 to A reversing contactor, for connection by lugs, order contactors LC DppA and mechanical interlock LAD CM (see page /). Component parts Auxiliary contact blocks and add-on modules: see pages / to /. () LC D0 to DA: clip-on mounting on mm rail AM DP or screw fi xing. LC D0 and D: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fi xing. LC D and D0: clip-on mounting on mm rail AM DP or screw fi xing. () Standard control circuit voltages (for other voltages between and 0 V, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0 D0 (D and D0 coils with integral suppression device fi tted as standard)) 0/0 Hz B D E F FE M P U Q V N R S LC D0 D 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c.supply Volts LC D0 DA (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () The weights indicated are for contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg for LC D0 to D, 0.0 kg for LC D0A to DA. () For reversing contactors with electrical interlocking pre-wired at the factory, add suffi x V to the references selected above. Example: LC D0P becomes LC D0PV. () For low consumption kit LA DBL (see page /). Note: when assembling a reversing contactor, it is good practice to incorporate a 0 ms time delay. 0 Selection : pages / to / / Characteristics : pages /0 to / Dimensions, schemes : pages / and /

28 References TeSys D, -pole reversing contactors for motor control up to kw at 00 V, in category AC- Horizontally mounted, pre-assembled -pole reversing contactors, for connection by spring terminals Pre-wired power connections. Mechanical interlock without electrical interlocking. LC Dpp Standard power ratings of -phase motors 0-0 Hz in category AC- (q y 0 C) 0 V 0 V V 0 V 00 V 0 V 0 V 00 V 0 V Rated operational current in AC- 0 V up to Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the voltage code () Fixing () Weight () kw kw kw kw kw kw A kg For connection by spring terminals... LC D0pp LC Dpp LC Dpp 0.0. LC Dpp () LC Dpp 0. Power connection by EverLink, BTR screw connectors () and control by spring terminals. 0 0 LC D0App () LC D0App ().0. 0 LC DApp ().0 For connection by Faston connectors All power connections are to be made by the customer. These contactors are fi tted with Faston connectors: x. mm on the power poles and x. mm on the coil terminals. For reversing contactors LC D0 and LC D only, in the references selected above, replace the fi gure before the voltage code with a fi gure. Example: LC D0pp becomes LC D0pp. Component parts Auxiliary contact blocks and add-on modules: see pages / to /. () LC D0 to D: clip-on mounting on mm rail AM DP or screw fi xing. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): a.c. supply Volts LC D0 DA 0/0 Hz B D E F FE M P U Q V N R S d.c. supply Volts LC D0 DA (coils with integral suppression device fi tted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC D0...D (coils with integral suppression device fi tted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to /. () The weights indicated are for reversing contactors with a.c. control circuit. For d.c. or low consumption control circuit, add 0.0 kg for LC D0 to D, 0.0 kg for LC D0A to DA. () Must be wired with x mm cables in parallel on the upstream side. On the downstream side, outgoing terminal block LAD may be used (Quickfi t technology, see page /).When wired with a single cable, the product is limited to A ( kw/00 V motors). () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () For low consumption kit LA DBL (see page /). 0 Selection : pages / to / Characteristics : pages /0 to / Dimensions, schemes : pages / and / /

29 References TeSys D, -pole changeover contactor pairs for control in category AC-, 0 to 00 A Pre-assembled. Pre-wired power connections. For connection by screw clamp terminals or connectors LC DT0 to LC DT0: mechanical interlock without electrical interlocking. LC D000: order separately auxiliary contact blocks LAD Np to obtain electrical interlocking between the contactors (see page page /). For electrical interlocking incorporated in the mechanical interlock, please consult your Regional Sales Offi ce. LC D00: mechanical interlock with integral, pre-wired electrical interlocking. LC DT0pp Utilisation category AC- Non-inductive loads Maximum rated operational current (q y 0 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the voltage code () Fixing () Weight A kg 0 LC DT0pp 0.0 LC DTpp 0.0 LC DTpp LC DT0pp 0.0 LC D000pp LC D00pp.00 For connection by lugs or bars 0 LC DT0pp 0.0 LC DTpp 0.0 LC DTpp LC DT0pp 0.0 For customer assembly. For connection by screw clamp terminals or connectors 0 LC DT0App () 0 LC DT0App () For connection by lugs or bars 0 LC DT0App () 0 LC DT0App () Accessories Auxiliary contact blocks and add-on modules: see pages / to /. () See note () on next page. () LC DT0 to LC DT0: clip-on mounting on mm rail AM DP or screw fi xing. LC D0: clip-on mounting on mm rail AM DP or mm rail AM DL or screw fi xing. LC D: clip-on mounting on x mm rails AM DP or screw fi xing. () For these operational currents, order identical contactors and a mechanical interlock LAD CM (see page /). Note: when assembling changeover contactor pairs, it is good practice to incorporate a 0 ms time delay. 0 Selection : pages / to / / Characteristics : pages /0 to / Dimensions, schemes : pages / and /

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

TeSys contactors. Rated operational. current in AC V up to. kw kw kw kw kw kw kw A kg

TeSys contactors. Rated operational. current in AC V up to. kw kw kw kw kw kw kw A kg Referenes TeSys ontators TeSys D ontators for motor ontrol up to kw at 00 V, in ategory AC- For onnetion y srew lamp terminals and lugs D0pp Dpp -pole ontators Standard power ratings of -phase motors 0-0

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

UL 1077 DIN Rail Supplementary Protectors

UL 1077 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide TeSys contactors From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting,

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL 400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

Cat. No. 140M-F M-D8E-B

Cat. No. 140M-F M-D8E-B Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational

More information

440V 500V V / / /2 12.

440V 500V V / / /2 12. -26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

6 - TeSys protection components: relays and controllers

6 - TeSys protection components: relays and controllers Contents - : relays and controllers Selection guide............................................. page / Motor and machine protection................................. page / TeSys K, thermal overload relays

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase

More information

5SP and 5SY Supplementary Protection UL 1077

5SP and 5SY Supplementary Protection UL 1077 Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic

More information

Masterpact. Installation recommendations

Masterpact. Installation recommendations 90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

TeSys DF IEC-Type Fuseholders

TeSys DF IEC-Type Fuseholders TeSys DF IEC-Type 9080CT080 08 Contents... Page Characteristics......3 Accessories... Dimensions...5 Wirg diagrams...5 Fuses...6 7 Characteristics TeSys DF IEC-Type Fuseholder type DF8 DF0 DF DF DFCC Environment

More information

5730A High Performance Multifunction Calibrator. Extended specifications

5730A High Performance Multifunction Calibrator. Extended specifications 730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack

More information

TeSys contactors 5. TeSys F contactors Auxiliary contact blocks. Maximum number of blocks per contactor Clip-on mounting

TeSys contactors 5. TeSys F contactors Auxiliary contact blocks. Maximum number of blocks per contactor Clip-on mounting s Auxiliary contact blocks ravailable nd half 00. Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts Maximum number of blocks per contactor Clipon mounting

More information

3VT4 Molded Case Circuit Breakers up to 1000 A

3VT4 Molded Case Circuit Breakers up to 1000 A VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

Installation Contactors ISU-xxx ISM-xxx

Installation Contactors ISU-xxx ISM-xxx Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

SIRCOVER Manual transfer switches from 125 to 3200 A

SIRCOVER Manual transfer switches from 125 to 3200 A Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM Unit Objectives Describe the structure of an atom. Identify atoms with a positive charge and atoms with a negative charge. Explain

More information

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information

2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible

More information

Interference suppression film capacitors MKP 336 1

Interference suppression film capacitors MKP 336 1 MKP RADIAL POTTED TYPE PITCH /15/22.5/27.5 mm l b h lt P d t CBA196 Fig.1 Simplified outlines. FEATURES to 27.5 mm lead pitch Supplied loose in box and taped on reel Consists of a low-inductive wound cell

More information

Zelio Relay - Solid State Relays

Zelio Relay - Solid State Relays Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage

More information

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN PANEL BOARDS ADDRESSED TO HAZARDOUS AREAS - PART THREE July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the

More information

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of

More information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,

More information

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:

More information

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018 Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers

More information

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS

More information

Miniatur Circuite Breakers (MCB)

Miniatur Circuite Breakers (MCB) Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

Double Thyristor Module For Phase Control MT A2

Double Thyristor Module For Phase Control MT A2 Electrically isolated base plate Industrial standard package Simplified mechanical design, rapid assembly Pressure contact PROTON-ELECTROTEX RUSSIA Double Thyristor Module For Phase Control MT3-595-18-A2

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link

More information

Modular contactors for installation into distribution

Modular contactors for installation into distribution Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular

More information

Film Capacitors. EMI suppression capacitors. Date: June 2018

Film Capacitors. EMI suppression capacitors. Date: June 2018 Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

DIN Timers TD. Options and ordering codes. Specification

DIN Timers TD. Options and ordering codes. Specification DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0 Class 0 CONTENTS Description Page R Miniature Plug-in Relays..................................... K Plug-in Relays.............................................

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

High Ohmic/High Voltage Resistors

High Ohmic/High Voltage Resistors High Ohmic/High Voltage Resistors VR68 A metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded

More information

Electrical installation solutions for buildings Technical details RCDs

Electrical installation solutions for buildings Technical details RCDs /1 Electrical installation solutions for buildings Technical details RCDs Index Functions and classification criteria for RCDs / Limitation of specific let-through energy I t /5 Peak current Ip /9 Coordination

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions FAULT CURRENT F F13-13 FAULT CURRENT - Contents 1. Introduction 2. Types of fault conditions 3 fault current must be determined 3.1 Purposes for which of prospective fault current magnitudes are used 3.2

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS

More information

Current protection I 2 t long-time protection

Current protection I 2 t long-time protection I 2 t long-time protection The long-time protection function protects cables against overloads. This function is based on true rms measurements. It is possible to select either I 2 t long-time protection

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information