TeSys enclosed starters 2
|
|
- Joel Ross
- 5 years ago
- Views:
Transcription
1 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature peration: - to + 0 C perating positions Same as for the TeSys K contactors Material Self-extinguishing ABS References Non-reversing starters Starter LE M, combined with short-circuit protection components, provides type or type coordination, depending on the type of devices used. Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 0 V 0 V 0 V 00 V V Setting range of thermal overload relay LR K () Basic reference, to be completed by adding the voltage code () kw kw kw kw A LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp LE Mpp 0.00 LE Mpppp.. 0 LE Mpp LE Mpp 0.00 Variant Replacement part b The standard version comprises: v TeSys contactor LC Kpp, v TeSys thermal overload relay LR K, v green Start button I, v red Stop/Reset button /R, v yellow operating indicator. b Control may be pulsed or maintained. b An earth terminal and a neutral terminal are provided on the bottom of the enclosure. b For safey applications, see enclosed starters: GV MC, LG K, LG D, LG K, LG D, LJ K, LG K and LJ K. Starter without thermal overload relay LR K Delete the last digits of the starter references selected above. Example: LE Mpp Basic reference, to be completed by adding the voltage code () Contactor LC KppA () For characteristics of TeSys K contactor, see pages /0 and /. For characteristics of TeSys thermal overload relay LR K, see pages /0 to /. () Thermal overload relay fitted as standard. () The contactor coil is pre-wired between phases of the power circuit. The codes indicated below therefore correspond to the power circuit voltage. Volts a 0/0 Hz Code B M P U Q V N R Example: 0/00 V -phase supply, kw motor: LE MQ. page / page / /
2 Dimensions, schemes TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Dimensions LE M () ("/) Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom PG IS PG IS LE M x to x x 0 or x x to x x 0 or x () Can be mounted on machine panel or frame. Knock-outs for x P cable glands. Schemes LE M I /R L L L T T T A A Reset/R /L U /L V M /L I W Choice of type of control built into the product Control by latching pushbuttons Control by spring return pushbuttons A B A H A KM Connection A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L ther voltages Terminal Terminal A B I /R A H A 0 References : page / /
3 Characteristics, references TeSys enclosed starters D..L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor 0 Characteristics Conforming to standards IEC 0--, IEC 0-, VDE 00-0 and EN 0 Degree of protection conforming to IEC 0 IP Ambient air temperature peration: - to + 0 C perating positions Same as for the TeSys K contactors Material Polycarbonate () References Standard power ratings of -phase motors 0-0 Hz in category AC- 0 V 00/ 0 V 00 V 0 V V Setting range of thermal trips Fixed magnetic tripping current Irth Basic reference, to be completed by adding the voltage code () kw kw kw kw kw A A LE GVME0Kpp LE GVME0Kpp LE GVME0Kpp.0 LE GVMEppKpp Variants LE GVME0Kpp LE GVMEKpp.0 0 LE GVMEKpp.0 Suffix to be added to the starter reference () Neutral terminal A 0 LE GVMEK Accessories (to be ordered separately) Reference Enclosure without starter, with sealing kit fitted (references of combination motor starters for customer assembly, see pages / and /) LE GVMEK 0.0 Padlocking device () to padlocks for GV ME operator (padlocking Ø to mm is only possible in the position) Mushroom head Stop pushbutton Ø 0 mm, red Sealing kit Sold in lots of Unit reference GV V0 0.0 Spring return () GV K0 0.0 Latching () IP Key release, GV K0 0.0 key n Turn to release GV K0 0. GV K0 () 0.0 IP for 0 GV E0 0.0 temperature between + C and + 0 C IP for 0 GV E0 0.0 temperature between - 0 C and + 0 C () Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts a 0/0 Hz Item B D E F M P U Q V N R ther voltages: please consult your Regional Sales ffice. () Example: LE GVME0KFA. () Supplied with IP sealing kit. () Padlockable in position using Ø to mm shank padlocks. page / page / /0
4 Dimensions, schemes TeSys enclosed starters D..L. starters for motor control, 0. to. kw with thermal magnetic circuit-breaker and contactor Dimensions LE GVMEK 0 Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom IS IS LE GV x 0 or x x 0 or x Schemes LE GVMEK 0 A L L L Q Q External control I A B A Connections A B 0 V, 0 V, 0 V L Neutral 0 V, 00 V, V, 0 V L L ther voltages Terminal Terminal 0 References : page /0 /
5 References TeSys enclosed starters Equipment for control in utilisation category AC-() (), without isolating device 0 References perational current up to Minimum c.s.a. of phase conductors Fuses to be fitted separately am gg For use with relay LR D or kit LA D (to be ordered separately) Basic reference, to be completed by adding the voltage code () A mm A A. LA D () LE Dpp LR D () LE Dpp 0.0. LR D () LE Dpp.0 LE D LA D0 () LE Dpp LE D0ppA0 ().0 0 LR D () LE D0pp.0 LE DppA0 () 0 LR D () LE Dpp LR D () LE D0pp.0 LE D LE D0ppA0 ().0 Specifications Enclosure LE D Double insulated, degree of protection IP LE D Double insulated, degree of protection IP LE D0...D0 Metal, degree of protection IP Control ( pushbuttons mounted on enclosure cover) LE D D0 No pushbuttons on cover LE DpppppA0 green Start button I red Stop/Reset button Connections LE D D0 Pre-wired control circuit connections () -phase 0/0 V, 0 V, 0/00 V or V 0/0 Hz. -core or Ph + N (unprotected neutral) insulated PVC cable, fixed to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature y C, conforming to NF C -00. () Control circuit voltage 0/0 Hz 0/0 V (code M) or 0/00 V (code Q). () rder the required LR D thermal overload relay separately, for use on balanced circuits only. () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA Dpp. () Equipment supplied without pushbuttons; external Start-Stop station required. 0 page / page / /
6 References (continued) TeSys enclosed starters Equipment for control in utilisation category AC-() (), without isolating device Variants (pre-assembled) Application Suffix to be added to the starter reference () No pushbuttons on cover LE D and D A0 blue Reset button R LE D D0 A0 green Start button I and red Stop button with N/C contact (for distribution circuits without thermal overload relay) LE D and D A0 -position selector switch -I ( : Stop; I : Manual Start) blue Reset button R Knock-outs for x mm plastic cable glands (instead of x mm plastic glands) LE D LE D A A0 neutral terminal (for -phase + N circuits) LE D D0 A Accessories (for customer assembly) Start pushbutton latching device for stay put operation (Start-Stop) Kits to provide Stop function without thermal overload relay fitted For use on Reference LE D D LA D LE D LA D 0.00 LE D LA D Miniature control circuit fuse holder size x 0, A/0 V Fuse supplied LE D LA D 0.00 LE D LA D 0.0 Pilot light with neon bulb, red lens and locking ring 0 V LE D and D LA D V LE D and D LA D , V LE D and D LA D 0.00 front-mounting block of auxiliary contacts, please consult your Regional Sales ffice LE D D0 LA DNpp () -phase 0/0 V or 0/00 V 0/0 Hz. -core or Ph + N (unprotected neutral) insulated PVC cable, fixed to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature y C, conforming to NF C -00. () rder the required LR D thermal overload relay separately, for use on balanced circuits only. Example: LE DMA0. ther versions Possible combinations of variants. Please consult your Regional Sales ffice. 0 page / page / /
7 Dimensions Enclosed starters D..L. starters and equipment, without isolating device Dimensions LE D LE D LE D0, D LE D0 0 0 () 0 c () 0 for LE DpppppA0 (without pushbuttons). Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE D x P x P LE D x P and x P x P LE D0 and LE D x P and x P x P and x P LE D0 x P and x P x P and x P 0 References : pages / and / page / /
8 Schemes Enclosed starters D..L. starters and equipment, without isolating device Schemes D..L. starters and equipment for control in category AC- LE D D0, LE DpppppA0 LE D /L U /L V LE D D0 W /L KM/ N I KM/ A A LE DpppppA0, LE DpppppA0 KM/ KM/ l N KM/ A A Remote control N KM/ l A A 0 References : pages / and / page / /
TeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationTeSys contactors. TeSys D contactors. 690 V on a and c
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V
More informationNR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition
s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;
More informationNR2 Thermal Overload Relay
Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationTeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P
Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationInstallation Contactors ISU-xxx ISM-xxx
Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationControl and signalling units Ø 22
Separate components and accessories : electrical blocks References Contact block with screw clamp terminal connections Description Type of contact Sold in Unit Weight lots of reference ZBE-0 N/O N/C Standard
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationDisplay counter electromechanical
Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationCat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationModular contactors for installation into distribution
Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular
More information6 - TeSys protection components: relays and controllers
Contents - : relays and controllers Selection guide............................................. page / Motor and machine protection................................. page / TeSys K, thermal overload relays
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E
The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationControl and signalling units Ø 22
Separate components and accessories : electrical blocks References Contact blocks with screw clamp terminal connections (1) Description Type of contact Sold in Unit Weight lots of reference ZBE-101 N/O
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More information2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids.
DOMINO Series. CONSUMER UNITS AND REFERENCE STANDARDS DIMENSIONS EN 60670- Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part : general requirements.
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationPanel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)
Staco Energy Products Co. has been a leading manufacturer of variable transformers for over 60 years, building standard as well as custom-designed products for industrial, commercial and military applications.
More informationS Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems
INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS Time base: 60 Hz (3-wire system) Quartz (2-wire system) Power input: 85 135 VAC / 60 Hz 7 28 VAC / 60 Hz Current consumption:
More informationElectromagnetism Review Sheet
Electromagnetism Review Sheet Electricity Atomic basics: Particle name Charge location protons electrons neutrons + in the nucleus - outside of the nucleus neutral in the nucleus What would happen if two
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
/way ball valve with electric rotary actuator, ball valve in plastic, N 50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Type 0 can
More information2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information
Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible
More informationair and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2
Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationZelio Relay - Solid State Relays
Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationMiniature Circuit Breaker
Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationTeSys contactors From 115 to 2750 A
Selection guide TeSys contactors From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting,
More informationCat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More information40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES
DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...
More informationRepair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:
Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationstations and enclosures 2
Presentation Control stations and enclosures For Harmony Ø control and signalling units XB 0 / General Control stations and enclosures For Harmony Ø control and signalling units XB Complete stations Stations
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More informationParts Manual R410A Models
Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System
More informationMotor Protection Circuit Breaker Series 8146/5-V27
> For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationTeSys contactors. Rated operational. current in AC V up to. kw kw kw kw kw kw kw A kg
Referenes TeSys ontators TeSys D ontators for motor ontrol up to kw at 00 V, in ategory AC- For onnetion y srew lamp terminals and lugs D0pp Dpp -pole ontators Standard power ratings of -phase motors 0-0
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationSION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism
Catalog HG.07 Edition 03/ 07 SION Lateral 3AE Vacuum Circuit Breaker with Lateral Operating Mechanism Medium-Voltage Equipment siemens.com/sion R-HG-3.psd Catalog HG.07 03 / 07 SION 3AE Vacuum Circuit
More information5. Positive charges one another.
1. Electric field lines indicate A. Both direction and relative strength B. Neither direction nor strength 5. Positive charges one another. A. Repel B. Attract 2. Whether or not charges will move in a
More informationXD1-L Cable Differential Protection Relay
XD1-L Cable Differential Protection Relay Manual XD1-L (Revision B) Woodward Manual XD1-L GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More information