TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P
|
|
- Lynn Glenn
- 6 years ago
- Views:
Transcription
1 Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,, () GV P GV AD, AM, AN, AU, AS GV AK00 X Block GV AD, AM, AN Block GV AU, AS 0 X,,, (), () Maximum X Electrical clearance 0 mm for Ue y V, or 0 mm for Ue 0 V, or 0 mm for Ue 00 and 0 V X 0 mm GV GH 0, /
2 Mounting, dimensions GV ME and GV P Mounting GV ME On mm rail On panel with adapter plate GV AF0 On pre-slotted plate AM PA On rails DZ MB0, AF EA 0/0 0/0 0 0 c c. on AM DP00 ( x.) c on AM DE00, ED00 ( x ) 0 GV AF0 DZ ME DZ MB0 GV P On rail AM DE00, ED00 ( x ) Panel mounted On pre-slotted plate AM PA AFEA Adapter plate GK AF0,, ±,,, Dimensions GV AF0 GV AF Combination GV ME + TeSys K contactor Combination GV ME + TeSys D contactor Combination GV P + TeSys D contactor b b c c GV ME + LC D0 D LC D and D GV P + LC D0 D LC D and D b.. b.. c. 0. c 0.. c.. c.. d d c c d d /
3 mounting (continued) GV ME and GV P Dimensions (continued) GV AF + LAD Combination GV ME + TeSys D contactor Combination GV P + TeSys D contactor GV ME + LC D0 D LC D and D GV P + LC D0 D LC D and D b.. b.. c.. c.. c.. c.. d d.. GV ME + GV L (current limiter). mm height compensation plate GV F0 X ± b ± b c c d d c c X 0 X mm for Ue 0 V or 0 mm for 0 V < Ue y 0 V, Mounting Mounting of external operator GV AP0 or GV AP0 for motor circuit-breakers GV P Door cut-out,..., /
4 mounting (continued) GV ME and GV P GV ME, GV P Sets of busbars GV G, GV G, GV G, with terminal block GV G0 a l p l p a GV G ( x mm) Number of tap-offs GV G ( x mm) 0 GV G GV G ( x mm) 0 GV G 0 GV G 0 Sets of busbars GV Gppp with terminal block GV G0 GVG0 Sets of busbars GV G, GV G, GV G l l GV G ( x mm) GV G ( x mm) GV G ( x mm) Sets of busbars GV G 0 Sets of busbars GV G and GV G l l GV G ( x mm) GV G ( x mm) /
5 mounting GV RT GV RT Dimensions, X, X, X: Electrical clearance 0 mm for Ue < 0 V Mounting Mounting of external operator GV AP0,,... On mm rail On panel with adapter plate GV AF0 On pre-slotted plate AM PA On rails DZ MB,, 0/0 AFEA 0/0, 0 0 c, GVAF0 DZME DZMB0 c 0 on AM DP00 ( x.) c on AM DE00, ED00 ( x ) /0
6 mounting GV P GV P Dimensions X X () () X Electrical clearance (ISC max) 0 mm for Ue y 00 V, 0 mm for Ue y 0 V () Blocks GV ANpp, GV ADpp and GV AM () Blocks GV AUpp and GV ASpp Note: Leave a gap of mm between circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible up to 0 C Mounting Mounting with TeSys contactor LC D0A DA Side by side mounting with TeSys contactor LC D0A DA (S-shape busbar system GV S) 0 Mounting on rail AM DE00 or AM ED0 Panel mounting, using M screws,, xø Mounting on pre-slotted plate AM PA,,, AF EA /
7 mounting GV P and GV ME0 GV P (continued) Busbar systems Set of busbars GV G Set of busbars GV G Note: Leave a space of mm between circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible up to 0 C. Mounting of external operator GV AP0 or GV AP0 Depth mm Depth to 0 mm Bracket,...,... 0 Depth to 0 mm Door cut-out Ø,... 0 xø, GV ME0 Dimensions,,, 0, X 0 X 0 0,, 0, () X Electrical clearance (ISC max) 0 mm for Ue y 00 V, 0 mm for Ue y 0 V () Blocks GV A0 A0. Mounting Mounting on rail AM DE00 or AM ED0 Panel mounting, using M screws Mounting on pre-slotted plate AM PA,,, AF EA /
8 mounting GV R GV R Dimensions () () for GV Rp0. Motor circuit-breakers with terminal shields or phase barriers GV R + GV AC0 or AC0 () Phase barriers: GV AC0 () Terminal shields: GV AC0 Combination of GV R and TeSys contactor LC F with kit GV AC0p Minimum electrical clearance c a GV R + LC F or F0 + GV AC0 a b c x GV R + LC F + GV AC0 x x GV R + LC F + GV AC0 b GV R + LC F + GV AC0 Minimum distance between circuit-breakers mounted side by side 0 x Painted or insulated metal plate, insulation or insulated bar Bare metal plate x x 0 0 U y 0 V 0 V < U < 00 V U u 00 V 0 /
9 mounting GV R GV R Panel mounting Mounting on mounting rails DZ MB0 DZME Flush-mounting circuit-breaker GV R n circuit-breakers GV R side by side Combination of GV R and TeSys contactor LC F with kit GV AC0p G E H E G H GV R + LC F + GV AC0 0 GV R + LC F0 + GV AC0 0 GV R + LC F + GV AC0 0 GV R + LC F + GV AC0 0 GV R + LC F + GV AC0 0 0 /
10 mounting (continued) GV R GV R Spreaders GV AC0 0 X Connection Z Smooth terminals 0, a Z X Connectors 0 Z X Direct rotary handle GV AP0, GV AP0 Flush-mounting a GV Rp0 Rp0. GV Rp0. I 0 Direct rotary handle GV AP0 or GV AP0 with conversion accessory GV AP0 Front face cut-out Enclosure viewed from top e, h 0 0 Door cut-outs require a minimum distance between the centre of the circuit-breaker and the door hinge point D u 0 + (h x ) ± 0 0 e to max Extended rotary handle GV AP0, GV AP0, 0 I 0 l l : min, 00 max The shaft of the extended rotary handle GV AP0 or GV AP0 must be cut to length: l mm. 0 /
11 Schemes GV ME, GV P, GV P and GV RT Schemes GV MEpp and GV RT GV Ppp GV Ppp /L /L /L /L /T /L /T /T /L /L /L /L /T /T /T /T /T /T Front mounting add-on contact blocks Instantaneous auxiliary contacts Front mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts GV AE GV AE GV AE0 GV AED GV AED0 or Side mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts GV AD0 GV AD0 GV AD GV AD0 Instantaneous auxiliary contacts Short-circuit signalling contacts GV AN GV AN0 GV AM () () () () 0 () () () () 0 0 Voltage trips Current limiter GV AUppp GV ASppp GV AXppp GV L D D /L D D D D /L /L E E Use of fault signalling contact and short-circuit signalling contact Connection of undervoltage trip for dangerous machines (conforming to INRS) on GV ME only Short-circuit signalling GV AM GV ADpp /L /L /L D Agl max D Trip signalling N/C or N/O Start-Stop contact /T /T /T E E /
12 Schemes GV ME0 and GV R Schemes Motor circuit-breakers Auxiliary contact block modules GV ME0 GV A0 GV A0 GV A0 GV A0 GV A0 GV A0 /T /T /T /L /L /L Fault signalling contacts Voltage trips GV A0 GV A0 GV B GV D D U D C C Motor circuit-breakers Add-on auxiliary contacts according to their location () GV R GV AE, GV AB /L /L /L Location C/O contact Location Trip indication Location Electrical fault indication Location C/O contact /T /T /T A self-adhesive label, supplied with the contact, can be affixed to the front face of the circuit breaker to allow personalised marking according to the function of the contact or contacts. () See pages /0 and /. Electric trips GV AUppp GV ASppp GV AD, AD D D C C 0ms Recommended application schemes GV AD, AD Fault indication Contactor opening on overload KA Reset 0ms KA Overload fault A KA A B 0ms Reset KA KM A A Associated components KA: CA KN or CAD N Associated components KA: CAD + LAD K or RHK KM: LC D or LC F /
13 mounting Magnetic motor circuit-breakers GV L and GV LE GV L Dimensions GV AD, AM, AN, AU, AS GV AK00 X Block GV AD, AM, AN Block GV AU, AS 0 X,,, (), X Electrical clearance 0 mm for Ue y V, or 0 mm for Ue 0 V, or 0 mm for Ue 00 and 0 V. X 0 mm. Mounting On rail AM DE00, Panel mounted AM ED00 ( x ) () Maximum On pre-slotted mounting plate AM PA Adapter plate GK AF0 AF EA Ø,, ±,,,,. mm height compensation plate GV F0 GV LE Dimensions GV AD, AM, AN, AU, AS GV AE X Block GV AD, AM, AN Block GV AU, AS,, X,,, () X Electrical clearance 0 mm for Ue y 0 V. () Maximum Mounting On mm rail On panel with adapter plate GV AF0 On pre-slotted plate AM PA On rails DZ MB0 c,, c 0 on AM DP00 ( x.) and on AM DE00, ED00 ( x),, 0/0 AF EA 0/0 GV AF0 0 0 DZ ME DZ MB0 /
14 mounting (continued) 0 Magnetic motor circuit-breakers GV L and GV LE GV L and GV LE Mounting of external operator GV AP0 or GV AP0 for GV L,..., Mounting of external operator GV AP0 for GV LE,,... Door cut-out xø, Ø Sets of busbars GV G, GV G, GV G, with terminal block GV G0 a l p l p GV G ( x mm) GV G ( x mm) 0 GV G ( x mm) 0 a Number of tap-offs GV G GV G 0 GV G 0 /
15 mounting Magnetic motor circuit-breakers GV L, GV LE Sets of busbars for GV L and GV LE Sets of busbars GV Gppp with term. block GV G0 GVG0 Sets of busbars GV G, GV G, GV GR l I GV G ( x mm) GV G ( x mm) GV G ( x mm) Set of busbars GV G 0 l Sets of busbars GV G and GV G I GV G ( x mm) GV G ( x mm) /0
16 mounting Magnetic motor circuit-breakers GV L GV L Dimensions X X () () X Electrical clearance (ISC max) 0 mm for Ue y 00 V, 0 mm for Ue y 0 V () Blocks GV ANpp, GV ADpp and GV AM () Blocks GV AUpp and GV ASpp Note: Leave a space of mm between circuit-breakers: either an empty space or side-mounting add-on contact blocks. Side by side mounting is possible up to 0 C. Mounting Mounting with Tesys contactor LC D0A DA and relay LR D Side by side mounting with Tesys contactor LC D0A DA (S-shape busbar system GV S) 0 Mounting on rail AM DE00 or AM ED0 Panel mounting, using M screws,, xø Mounting on pre-slotted plate AM PA Set of busbars GV G Set of busbars GV G AF EA,,, /
17 mounting (continued) Magnetic motor circuit-breakers GV L and GK EF0 GV L (continued) Mounting of external operator GV AP0 or GV AP0 Depth mm Depth to 0 mm Bracket,...,... 0 Depth to 0 mm,... 0 Door cut-out Ø xø, GK EF0 0 X GK EF0 + GK AX 0 0, X a Number of GK AX 0 a... /
18 Schemes 0 Magnetic motor circuit-breakers GV L, GV LE, GV L and GK EF0 Magnetic motor circuit-breakers GV Lpp GV LEpp GV Lpp GK EF0 /L /L /L /L /L /L /L /L /L /T /T /T /T /T /T /T /T /T Accessories Front mounting add-on contact blocks Instantaneous auxiliary contacts GV AE GV AE GV AE0 GV AED and GV AED0 OR Side mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts GV AD0 GV AD0 GV AD GV AD0 Instantaneous auxiliary contacts Short-circuit signalling contacts GV AN GV AN0 GV AM () () () () () () () () Voltage trips GV AUppp GV ASppp D D C C Start-Stop signalling contact blocks GK AX GK AX0 GK AX0 Fault signalling contact blocks GK AX GK AX GK AX /
TeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationMiniature Circuit Breaker
Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload
More informationMasterpact. Installation recommendations
90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationMoulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type
TPact Moulded Case Circuit Breakers TPact Moulded Case Circuit Breaker. General Certificates: KEMA,CB; Electric ratings: AC0/0Hz, AC0V~90V DC0V~00V, A~0A; Standard: IEC/EN 097.. Type Designation TPact...
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationTeSys contactors. Rated operational. current in AC V up to. kw kw kw kw kw kw kw A kg
Referenes TeSys ontators TeSys D ontators for motor ontrol up to kw at 00 V, in ategory AC- For onnetion y srew lamp terminals and lugs D0pp Dpp -pole ontators Standard power ratings of -phase motors 0-0
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More information6 - TeSys protection components: relays and controllers
Contents - : relays and controllers Selection guide............................................. page / Motor and machine protection................................. page / TeSys K, thermal overload relays
More information40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES
DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationTeSys contactors. TeSys D contactors. 690 V on a and c
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationNM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- /
P0. Type designation N M / Type of Npole for P breaker* pplication: lank: for power distribution; : for motor protection elease type and accessory code (please refer to table on page 9) Number of poles
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More information1 Linear feeder 2 Track 3 Cover 4 Side plate 5 Trim weight 6 Sub-structure. 8 Feeding technology afag.com
Linear feeder Track Cover Side plate Trim weight Sub-structure 8 Feeding technology 0 Linear feeder Linear feeder Linear feeder HLF-M Linear feeder HLF-P 8 Control devices PSG Accessory HLF Linear feeder
More informationZUCCHINI MR - MEDIUM RATING BUSBAR
ZUCCHINI MR - MEDIUM RATING BUSBAR Available in sizes from 0 to 000 A, MR (medium rating) busbar is ideal for power distribution in medium to large installations and rising mains in commercial buildings.
More informationNR2 Thermal Overload Relay
Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping
More informationNR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition
s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationCat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More informationNon-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21
s e r i e s c3controls offers the most rugged, dependable Disconnect Switches that money can buy. From Panel/Base Mount to Door Mount with switch ratings from 16A - 125A, we ve got what you need. And,
More informationDATA SHEET: TEMPOWER2 ACB
Electrical haracteristics to IE 097, IE 097 Type Series AMERE RATING(A) AR0SB Standard RATED URRENT (max) [I n ](A) JIS,IE, EN, AS NEMA, ANSI Marine NEUTRAL OLE AMERES FRAME (A) NUMBER OF OLES 3 RATED
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More information2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information
Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationRodless cylinders Series 1600
Rodless cylinders Series 00 Basic version 0.Ø.stroke.0.M Max. stroke mt.) AL AI RA RB AF TC AM L LA+stroke AH TD AE TA RV Possibility of a single feed cylinder head AI AP AB AC AD TD TE TB AG RT Left head
More informationMiniatur Circuite Breakers (MCB)
Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage
More informationRepair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:
Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationSemiconductor (AC) fuses
PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationVCB. Vacuum Circuit Breaker 17.5kV, kA, A 24kV,...16kA,...800A. User Guide
VCB Vacuum Circuit Breaker 7.5kV,...3.5kA,...2000A 24kV,...6kA,...800A User Guide Contents. Product description... 4. Abbreviations... 5.2 Definitions... 5.3 Main technical parameters... 6.4 Disclaimers...
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data... Heat
More informationCOLGED. Toptech
COLGED SPARE PARTS CATALOGUE ERSATZTEILKATALOG CATALOGUE PIECES DETACHEES CATALOGO PARTI RICAMBIO CATALOGO DE PIEZAS DE RECAMBIO CATALOGO PECAS, DE REPOSICAO Toptech -. -09-0 R L 9 0 0 0 0 9 MOD T0 MOD
More informationBlocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers
Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationCPI SNOW PLOW KIT ASSEMBLY INSTRUCTIONS
CPI SNOW PLOW KIT ASSEMBLY INSTRUCTIONS Thank you for purchasing the CPI Snow Plow Kit! These instructions will walk you through the basic assembly of the snow plow kit. Contents Each kit contains the
More informationMOULDED CASE CIRCUIT BREAKERS BL1000S
G MOUDED CASE CRCUT BREAKERS BS G BS COMMERCA NFORMATON P Switching units, withdrawable device, plug-in device...g Overcurrent releases...g Signalling units...g Connecting sets...h Switches...H Shunt trips...h
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationTeSys contactors 5. TeSys F contactors Auxiliary contact blocks. Maximum number of blocks per contactor Clip-on mounting
s Auxiliary contact blocks ravailable nd half 00. Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts Maximum number of blocks per contactor Clipon mounting
More information32 Input AC Block I/O Module
Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through
More informationInstruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution
Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury
More informationRotary Switches AC09, 16 and 32
09, 16 and 32 igital code output type escription FUJI series rotary switches offer a wide choice of output codes. They feature sliding u-flashed contacts for high contact reliability. Inhibitor and parity
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance
More informationSingle cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style
Type Model/size Stroke -SS-0-N. -SS-0-N. Single cam type -SS- 7. -SS-. -SS-4. -SD-0 Double cam type -SD- -SD-4. Screw type straight style Screw type tee style -FS- -FT- -FS- -FT- 0.9 1. 1.. 1. 4 Grip forcen
More informationControl and signalling units Ø 22
Separate components and accessories : electrical blocks References Contact block with screw clamp terminal connections Description Type of contact Sold in Unit Weight lots of reference ZBE-0 N/O N/C Standard
More information15.0 UNDERCOUNTER CUBERS EUC150B2 EUC200B3-EUC200-UC20B-UC20 AIR AND WATER COOLED
15.0 UNDERCOUNTER CUBERS EUC150B2 EUC200B3-EUC200-UC20B-UC20 AIR AND WATER COOLED Item EUC EUC EUC EUC UC UC Code Part Description Part Number GRP 150 200B3 200 206 20B 20 Shaded Item Code indicates updated
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key
More informationMINIATURE MICROSWITCHES - PREMIUM
0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationTechnical catalogue SmiSSline electrical protective devices in a system
Technical catalogue SmiSSline electrical protective devices in a system SmiSSline The original Shaping the future SmiSSline protection devices are simply snapped into a plug-in socket system. The arduous
More informationPARTS LIST GAS BOILERS MODELS:
PARTS LIST GAS BOILERS MODELS: CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) CG330 (E) southbend A MIDDLEBY COMPANY 1100 Old Honeycutt Fuquay-Varina, NC 27526 (919) 552-9161 FAX (919) 552-9798
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,
More information12 Volt High Speed Train Lego # 7745 Qty PartNum Color Description Picture Note
1 4083 Black Bar 1 x 4 x 2 with Studs 8 3009 Black Brick 1 x 6 8 3005 Black Brick 1 x 1 10 3009 Red Brick 1 x 6 4 3005 Red Brick 1 x 1 8 3062b Black Brick 1 x 1 Round with Hollow Stud 7 3009 White Brick
More informationParts List, Wiring Diagrams
Parts List, Wiring Diagrams PAE180-300 SERIES PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST----------- 2-11 PARTS DRAWING----- 12-34 WIRING DIAGRAMS--- 35-48 Printed in U.S.A. 7/28/08 KEY
More informationModular contactors for installation into distribution
Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular
More informationParts Manual R410A Models
Parts Manual R410A Models PTAC - PD Series (Electronic Controls) Packaged Terminal Air Conditioners Packaged Terminal Heat Pumps PTAC PARTS E (1-2010) Table of Contents Unit Identification... 2 PTAC System
More informationProtected. Main specifications. Additional specifications. Product adaptations
Protected 83 06 Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard 83 06 0 stable lever positions 83 06 4 stable plunger
More informationTeSys contactors From 115 to 2750 A
Selection guide TeSys contactors From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting,
More informationDigital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW
Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:
More informationVacuum capacitors overview Capacitor selection guides
JENNINGS TECHNOLOGY Vacuum capacitors overview Capacitor selection guides Capacitors by type Capacitor type Vacuum variable Capacity max. (pf) Test voltage / Hz Model no. series Page number 7.,, 1 CVDD-
More information6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE
6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE Item EC EC EC EC EC EC Code Part Description Part Number GRP 200 300 400 406 500 606 AIR COOLED 5 Air Condenser 9141048-01 AC X
More informationRedline Unibis : the solution Circuit protection
2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationGPS1B. Characteristics. Technical performances
Thermal and magnetic protection PS Motor protection devices Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics
More informationREPAIR PARTS. MBE/MBR Air Handlers
REPAIR PARTS MBE/MBR Air Handlers MBE1200AA-1AA MBE1200AA-1BA MBE1600AA-1AA MBE1600AA-1BA MBE2000AA-1AA MBE2000AA-1BA MBR0800AA-1AA MBR1200AA-1AA MBR1600AA-1AA MBR2000AA-1AA Goodman Manufacturing Company,
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 6 0 V reaker amily Y - mpere rame - 0 mpere rame K - 0 mpere rame L - mpere rame M 00
More information