40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Size: px
Start display at page:

Download "40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES"

Transcription

1 DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices... EURODIN Accessories for conduits and cables... EUROBOX Protective conduits... EUROPASS Residential flush-mounting enclosures... EURODOMO Junction boxes... EUROBOX TERMINAL SYSTEMS Boxes for modular ranges... EURODOMO PLAYBUS Range... EURODOMO SYSTEM Range... EURODOMO SAFETY SYSTEMS Safety/emergency enclosures... EUROBOX

2 0 CDK Range Characteristics and advantages Easy access also with conduits of diameter up to 50 mm thanks to the fully removable knockouts. Possibility of separating circuits in accordance with the CEI 6-8 standard by means of the compartment dividers ( GW ). DISTRIBUTION BOARDS Impossible to break and correct door coupling guaranteed thanks to the innovative catch with flexible hinges. Possibility of installing circuit breakers up to 125A thanks to the rails set apart with a centre distance of 175 mm (starting from 36 modules). Wiring done even at the bench by means of the removable frame with simplified wiring. Accessible only for authorized personnel using the security lock GW Fast, error-free installation with the possibility of deciding the direction of opening the door thanks to the reversible front and back. APPLICATION SOLUTIONS 18-module enclosure Control and protection and auxiliary services in flats and apartments where modules are required to be available in a small space. 2-module distribution board Control, protection and auxiliary services in houses and flats where circuits need to be separated. Combined distribution board with instruments, warning lights, isolator and modular devices Control, measurement and protection in highly electrified installations with access for authorized personnel only. 5

3 DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS 0 CDK Range Selection Guide General characteristics Enclosures Distribution boards Colour: White RAL 9016 Protection rating: IP 0 Door: Smoked transparent No. modules EN (17.5 mm) Code (12) 36 (18x2) 5 (18x3) 72 (18x) GW GW GW GW 0 60 GW GW GW GW GW GW COMPLEMENTARY ITEMS MISCELLA NEOUS FOR WIRING FOR INSTALLATION AND COUPLING Non-deforming brackets for walling back-mounting boxes Combination coupling element Set of long screws with spacers Insulated neutral and earth terminal blocks Internal horizontal dividers Blank cover panels 1 module high for CDK distribution boards Metal security cylinder lock GW 0 25 GW 0 25 GW 0 25 GW 0 25 GW 0 25 GW 0 25 GW 8 65 GW 8 65 GW 8 65 GW 8 65 GW 8 65 GW 8 65 GW 8 65 GW 0 01 GW 0 02 GW 0 0 GW 0 02 GW 0 0 GW 0 87 GW 0 88 GW 0 95 GW 0 22 GW 0 22 GW 0 22 GW 0 22 GW 0 22 GW 0 22 GW 0 22 GW 0 22 GW 0 79 GW 0 79 GW 0 96 GW 0 0 GW x GW 0 96 GW 0 22 GW 0 79 GW 8 65 GW 0 0 3x GW 0 88 x GW 0 96 GW

4 Flush-mounting modular distribution boards and enclosures - White RAL IP 0 - ( ) Smoked transparent door IP 0 0 CDK RANGE Enclosures and distribution boards equipped with terminal block for plasterboard walls - Smoked transparent door DISTRIBUTION BOARDS GW GW GW GW 0 60 GW GW No. modules Installable terminal blocks Dispersable power EN N Neutral - no. holes per sect. (mm 2 ) (CEI 23-9) (17.5 mm) Earth - no. holes per sect. (mm 2 ) (W) GW x 160 x GW x 160 x GW x 170 x GW x 195 x 85 GW x 270 x 85 GW x 310 x 85 N (1 x 25) + (7 x 10) (1 x 25) + (7 x 10) N (3 x 25) + (10 x 10) (3 x 25) + (10 x 10) N (5 x 25) + (1 x 10) (5 x 25) + (1 x 10) ACCESSORIES SUPPLIED Standard: Module masks, circuit labels. Specific: GW 0 60, GW and GW 0 608, self-adhesive plates to be compiled for certification to the Italian CEI standard. CHARACTERISTICS: GW 0 601, envisaged without the door and with the rail EN secured directly onto the base. GW 0 602, GW 0 603, GW 0 60, GW 0 605, GW 0 608, with door fitted to accommodate the cylinder security lock GW Info Point 0 CDK RANGE Distribution boards with panels with window and removable frame - fitted to accommodate terminal blocks Smoked transparent door + 20% space inside - 20% installation time GW GW No. modules Installable terminal blocks Dispersable power EN N Neutral - no. holes per sect. (mm 2 ) (CEI 23-9) (17.5 mm) Earth - no. holes per sect. (mm 2 ) (W) 2 N (3 x 25) + (10 x 10) GW x 20 x (12 x 2) (3 x 25) + (10 x 10) 36 N (10 x 25) + (28 x 10) GW x 505 x 85 (18 x 2) (10 x 25) + (28 x 10) 5 N (10 x 25) + (28 x 10) GW x 680 x 95 (18 x 3) (10 x 25) + (28 x 10) 72 N (10 x 25) + (28 x 10) GW x 855 x 95 (18 x ) (10 x 25) + (28 x 10) GW GW ACCESSORIES SUPPLIED Standard: Module masks, circuit labels. Self-adhesive labels to be compiled for certification to the Italian CEI standard. CHARACTERISTICS: Doors fitted to take the security cylinder lock GW ( ) Total insulation to EN standard. Complementary items: pages ENCLOSURES AND BOXES (GWT 850 C) FOR PLASTERBOARD WALLS Distribution enclosures Junction boxes Boxes for domestic ranges Technical sheets: pages Dimensions: page 237 Complementary system items: page Complementari items of installation: page 51 Characteristics and advantages: page 5 0 CD Range 8 PT Range 2 Range 7

5 DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS Flush-mounting enclosures - Grey RAL IP 0 - ( ) Smoked transparent door IP 0 Modular enclosures with provision to house terminal blocks Transparent smoked door GW GW GW GW GW GW No. modules Installable terminal blocks Dispersable power EN N Neutral - no. holes per sect. (mm 2 ) (CEI 23-9) (17.5 mm) Earth - no. holes per sect. (mm 2 ) (W) GW x 153 x GW x 159 x GW x 167 x GW x 195 x 89 GW x 217 x 89 N (1 x 25) + (7 x 10) (1 x 25) + (7 x 10) N (3 x 25) + (10 x 10) (3 x 25) + (10 x 10) GW N (2 x 25) + (1 x 10) 326 x 36 x 89 (12 x 2) (2 x 25) + (1 x 10) GW N (6 x 25) + (20 x 10) 53 x 396 x 95 (18 x 2) (6 x 25) + (20 x 10) GW N (6 x 25) + (20 x 10) 53 x 56 x 95 (18 x 3) (6 x 25) + (20 x 10) GW N (6 x 25) + (20 x 10) 63 x 707 x 95 (18 x ) (6 x 25) + (20 x 10) ACCESSORIES SUPPLIED Standard: Module masks, circuit labels, spare hinge. Specific: GW 0 205, GW 0 207, GW 0 209, GW 0 211, GW 0 213, GW 0 235, self-adhesive label to be compiled for certification in compliance with the Italian standard CEI CHARACTERISTICS: GW 0 207, GW 0 209, GW 0 211, GW 0 213, GW 0 235, door fitted with lock with 2 triangle keys. GW e GW 0 202, envisaged without door. GW GW GW GW Modular enclosures equipped with terminal block Transparent smoked door No. modules Terminal blocks supplied Dispersable power EN N Neutral - no. holes per sect. (mm 2 ) (CEI 23-9) (17.5 mm) Earth - no. holes per sect. (mm 2 ) (W) GW x 217 x 89 N (3 x 25) + (10 x 10) (3 x 25) + (10 x 10) GW N (2 x 25) + (1 x 10) 326 x 36 x 89 (12 x 2) (2 x 25) + (1 x 10) GW N (6 x 25) + (20 x 10) 53 x 396 x 95 (18 x 2) (6 x 25) + (20 x 10) ACCESSORIES SUPPLIED: Module masks, circuit labels, spare hinge. CHARACTERISTICS: Door fitted with lock with 2 triangle keys GW Complementary items: pages Technical sheets: pages Dimensions: page 238 Complementary system items: page Complementary items of installation: page 51 GW ( ) Total insulation to EN standard. 8

6 Residential flush-mounting enclosures - IP 0 - ( ) Smoked transparent door IP 0 Modular enclosures with provision to house terminal blocks Transparent smoked door DISTRIBUTION BOARDS Info Point New Toner Black colour designed to blend in perfectly with the PLAYBUS Range plates. GW GW GW GW External Dispersable No. modules Installable terminal blocks dimensions power EN N Neutral - no. holes per sect. (mm 2 ) Colour (CEI 23-9) (17.5 mm) Earth - no. holes per sect. (mm 2 ) (W) GW White x 160 x 85 GW Toner black GW N (1 x 25) + (7 x 10) White x 185 x 72 GW (1 x 25) + (7 x 10) Toner black 12 GW N (3 x 25) + (10 x 10) White x 190 x 72 GW (3 x 25) + (10 x 10) 22 Toner black 8 GW N (2 x 25) + (1 x 10) White x 330 x 80 (2 x 12) GW 0 23 (2 x 25) + (1 x 10) 31 Toner black 6 GW N (6 x 25) + (20 x 10) White 310 x 83 x 90 5 (3 x 12) GW 0 20 (6 x 25) + (20 x 10) Toner black ACCESSORIES SUPPLIED Standard: Module masks, circuit labels. Specific: GW 0 225, GW 0 226, GW 0 229, GW 0 230, GW 0 233, GW 0 23, GW 0 239, GW 0 20, self-adhesive label to be compiled for certification in compliance with the Italian standard CEI GW GW GW GW GW GW 0 23 GW GW Modular enclosures equipped with terminal block Transparent smoked door No. modules EN (17.5 mm) External dimensions Dispersable Terminal blocks supplied power N Neutral - no. holes per sect. (mm 2 ) Colour (CEI 23-9) Earth - no. holes per sect. (mm 2 ) (W) GW N (3 x 25) + (10 x 10) White x 190 x 72 GW (3 x 25) + (10 x 10) 22 Toner black 8 GW N (2 x 25) + (1 x 10) White x 330 x 80 (12) GW (2 x 25) + (1 x 10) 31 Toner black 6 GW N (6 x 25) + (20 x 10) White 310 x 83 x 90 (3x12) GW 0 22 (6 x 25) + (20 x 10) 5 Toner black ACCESSORIES SUPPLIED: Module masks, circuits labels. GW GW 0 20 GW 0 21 GW 0 22 ( ) Total insulation to EN standard. GEWISS DOMESTIC ENCLOSURES Intelligent electronic control units Co-ordinated decorative enclosures EURODOMO Catalogue 0 CD Range 9

7 DISTRIBUTION BOARDS SURFACE AND FLUSH MOUNTING DISTRIBUTION BOARDS Complementary items for installation and coupling Fixing bracket 0 CDK RANGE - SURFACE Wall fixing bracket, complete with self-tapping screws Pack/ For enclosures/distribution boards GW 621 All wall types 0/80 Aesthetic cover for conduit entry 0 CDK RANGE - SURFACE Aesthetic coupling covers for conduit and trunking entry for CDK distribution boards and enclosures For enclosures/distribution boards Fixing with rail EN GW modules 20 Clip GW modules 20 CHARACTERISTICS: The cover is equipped with internal knockouts for finishing with trunking size from 60 x 30 mm up to 200 x 60 mm. Anti-deformation bracket for flush-mounting base boxes 0 CDK RANGE - FLUSH Anti-deformation brackets for walling CDK enclosure base boxes For distribution boards with rail EN GW modules 20 Prevents deforming back-mounting boxes during masonry work. Coupling component for flush-mounting base boxes 0 CDK RANGE - FLUSH Combined coupling component for CDK flush-mounting distribution boards and enclosures Fixing GW 0 25 Clip 10 For enclosures and distribution boards of dimensions starting from 12 modules Set of long screws 8 PTC RANGE Set of long self-tapping screws with spacers for fixing lids and fronts Screw dimensions Spacer thickness Pack/ GW 8 65 Ø x5 max 10, reducible 1/100 CHARACTERISTICS: This set can also be used for the following flush-mounting ranges: CD/CDK Range (starting from 6 modules), 8 CM Range and 2 RV Range. Permits securing the front cover to the flush-mounting box when this is not walled flush with the wall (eg, tiled surface). 50

8 Complementary wiring items Terminal blocks for enclosures and distribution boards - SURFACE AND FLUSH MOUNTING Insulated neutral and earth terminal blocks for surface and flush mounting enclosures and distribution boards Neutral Earth For enclosures/ Fixing terminal block terminal block distribution boards with to the enclosure No. holes x sect. (mm 2 ) No. holes x sect. (mm 2 ) rail EN GW 0 01 (1 x 25) + (7 x 10) (1 x 25) + (7 x 10) 8 modules with screws 20 GW 0 02 (3 x 25) + (10 x 10) (3 x 25) + (10 x 10) 12 modules with screws 20 GW 0 0 (5 x 25) + (1 x 10) (5 x 25) + (1 x 10) 18 modules and/or clip 20 ACCESSORIES SUPPLIED: Fixing screws. DISTRIBUTION BOARDS Dividers for CDK distribution boards 0 CDK RANGE - SURFACE AND FLUSH MOUNTING Internal horizontal dividers for CDK distribution boards For distribution boards Pack/ Fixing with rail EN GW modules Friction 10/100 GW modules coupling 10/100 Blank panels for CDK distribution boards 0 CDK RANGE - SURFACE AND FLUSH MOUNTING Blank cover panels 1 module high for CDK distribution boards For distribution boards Colour installation type with rail EN GW 0 92 Surfacemounting 12 modules Grey 20 GW modules RAL GW 0 95 Flushmounting 12 modules White 20 GW modules RAL Miscellaneous complementary items Triangle key - SURFACE AND FLUSH MOUNTING Insulating triangular key Pack/ Description GW 0 21 Insulated triangle key 10/100 Security/safety lock - SURFACE AND FLUSH MOUNTING Cylindrical security/safety lock Pack/ Material GW 0 22 Die-cast metal 1/10 ACCESSORIES SUPPLIED: No. 2 keys. All keys are supplied with a standardized. COMPLEMENTARY INSTALLATION ITEMS MP Range 52 FS Range 7 PS Range 51

9 DISTRIBUTION BOARDS COUNTRY-SPECIFIC DISTRIBUTION BOARDS Cassette da parete RAL GW PLAST 120 C NEW Reference standards BS EN BS EN Reference standards NF C NF EN NF EN Technical specification EDF HN 62-S-81 Reference standard RU 107 D Reference standards VDE 0603 DIN

10 Spanish standard protected surface-mounting enclosures - Grey RAL IP 0 - ( ) Individual ICP with no door IP 0 Enclosure to house "ICP" power limiting circuit breaker In = 0A - Without door - sealable No. modules Dimensions Classification EN R.U. 107-D (17.5 mm) GW x 195 x 76 CS-ICP32 30 ACCESSORIES SUPPLIED: Circuit labels. DISTRIBUTION BOARDS Spanish standard decorative protected flush-mounting enclosures - White RAL IP 0 - ( ) ICP + circuit protection with no door IP 0 Distribution enclosures with housing for "ICP" power limiting circuit breaker In = 0A - Without door No. modules EN (17.5 mm) Dimensions Classification R.U. 107-D ICP Compartment Circuit breaker compartment GW x 195 x CCE-ICP32 GW x 195 x ACCESSORIES SUPPLIED: Circuit labels. CHARACTERISTICS: Sealable ICP compartment. ICP + circuit protection with door Distribution enclosures with housing for "ICP" power limiting circuit breaker In = 0A - Smoked transparent door No. modules EN (17.5 mm) Dimensions Classification R.U. 107-D ICP Compartment Circuit breaker compartment GW x 225 x CCE-ICP32 GW x 225 x ACCESSORIES SUPPLIED: Circuit labels. CHARACTERISTICS: Sealable ICP compartment. Technical sheets: pages Dimensions: page 239 ( ) Full insulation to EN Standard 53

11 DISTRIBUTION BOARDS COUNTRY-SPECIFIC DISTRIBUTION BOARDS German standard watertight surface-mounting distribution boards and enclosures - Grey RAL IP 65 - ( ) Flange with knockout holes IP 65 0 CDK RANGE Distribution boards and enclosures equipped with terminal blocks and 2 interchangeable flanges - Smoked transparent door - GWT 750 C 2 flanges with knockout holes GW x 260 x 10 GW 0 11 No. modules Terminal blocks supplied EN N Neutral - no. holes per sect (mm 2 ) (17.5 mm) Earth - no. holes per sect. (mm 2 ) N (3 x 25) + (10 x 10) (3 x 25) + (10 x 10) 2 N (3 x 25) + (10 x 10) 298 x 20 x 10 (12) (3 x 25) + (10 x 10) 6 GW N (6 x 25) + (20 x 10) 298 x 570 x 10 (13) (6 x 25) + (20 x 10) ACCESSORIES SUPPLIED: Screw caps for double insulation, module masks, circuit labels. CHARACTERISTICS: Each flange is equipped with the following knockout holes: 8 Ø 20, 2 Ø 29, 1 Ø 37. Possibility of replacing the flanges supplied with GW 0 28 flanges equipped with quick entry cable glands. Flange with knockout holes and quick entry 0 CDK RANGE Distribution boards and enclosures equipped with terminal blocks and 2 interchangeable flanges - Smoked transparent door - GWT 750 C 1flange with knockout holes + 1 flange with quick entry stepped glands No. modules Terminal blocks supplied EN N Neutral - no. holes per sect (mm 2 ) (17.5 mm) Earth - no. holes per sect. (mm 2 ) N (3 x 25) + (10 x 10) GW x 260 x 10 (3 x 25) + (10 x 10) 2 N (3 x 25) + (10 x 10) GW x 20 x 10 (12) (3 x 25) + (10 x 10) 6 GW N (6 x 25) + (20 x 10) 298 x 570 x 10 (13) (6 x 25) + (20 x 10) ACCESSORIES SUPPLIED: Screw caps for double insulation, module masks, circuit labels. CHARACTERISTICS: Flange with knockout holes: 7-8 Ø 20, 2 Ø 29, 1 Ø 37. Flange with quick entry stepped glands. Complementary items Flange with stepped glands 0 CDK RANGE Interchangeable flange with quick entry stepped glands for CDK distribution boards and enclosures Entries per flange Pack/ N. Ø cables GW / Technical sheets: pages Dimensions: page 20 ( ) Full insulation to EN Standard, obtainable with screw caps or resin fixing brackets GW

12 German standard protected flush-mounting enclosures - White RAL IP 30 - ( ) Masonry walls Enclosures for masonry walls equipped with terminal blocks Blanking door and metal frame No. modules Terminal blocks supplied EN (17.5 mm) Neutral - no. holes per sect. (mm 2 ) Earth - no. holes per sect. (mm 2 ) GW (1x25) + (3x16) + (1x10) (1x25) + (3x16) + (1x10) GW (12) (25) + (6x16) + (16x10)* (1x25) + (3x16) + (1x10) GW (13) (25) + (6x16) + (210)* (1x25) + (5x16) + (210) 3 GW (1) (25) + (6x16) + (210)* (1x25) + (5x16) + (210) 2 ACCESSORIES SUPPLIED: Labels with self-adhesive symbols to identify circuits, positioning brackets for the masonry at the back, mortar guard, certification label. CHARACTERISTICS: Doors fitted to accommodate security lock GW * Composed of 2 terminal blocks. DISTRIBUTION BOARDS Plasterboard walls Complementary items Enclosures for plasterboard walls equipped with terminal blocks Blanking door and metal frame - (GWT 850 C) No. modules Terminal blocks supplied EN (17.5 mm) Neutral - no. holes per sect. (mm 2 ) Earth - no. holes per sect. (mm 2 ) GW (1x25) + (3x16) + (1x10) (1x25) + (3x16) + (1x10) GW (12) (25) + (6x16) + (16x10)* (1x25) + (3x16) + (1x10) GW (13) (25) + (6x16) + (210)* (1x25) + (5x16) + (210) 3 GW (1) (25) + (6x16) + (210)* (1x25) + (5x16) + (210) 2 ACCESSORIES SUPPLIED: Labels with self-adhesive symbols to identify circuits, removable top wall with knockouts for cable entry (spare), certification label. CHARACTERISTICS: Removable top wall with knockouts for cable entry. Doors fitted to accommodate security lock GW * Composed of 2 terminal blocks.. Pair of joints for masonry backing Terminal blocks Pair of joints for coupling combinations of German standard flush-mounting enclosures for masonry walls Fixing GW 0 61 Clip 20 Terminal blocks with support for German standard flush-mounting enclosures Neutral terminal blocks Earth terminal blocks no. holes x sect. (mm 2 ) no. holes x sect. (mm 2 ) For enclosures no. modules EN (17.5 mm) GW 0 51 (1x25) + (3x16) + (1x10) (1x25) + (3x16) + (1x10) GW 0 52 (1x25) + (3x16) + (8x10) (1x25) + (3x16) + (1x10) 2 20 (1x25) + (3x16) + (8x10) GW 0 53 (1x25) + (3x16) + (8x10) (1x25) + (5x16) + (210) (1x25) + (3x16) + (1x10) CHARACTERISTICS: Clip fixing. Internal dividers Internal dividers for German standard flush-mounting enclosures Type For enclosures no. modules Fixing of division EN (17.5 mm) Security lock GW GW Vertical GW Clip 30 GW GW 0 60 Horizontal Security lock for German standard flush-mounting enclosures Material GW 0 63 Metal 1/10 ACCESSORIES SUPPLIED: 2 keys with standardized. Pack/ ( ) Full insulation to EN Standard. 55

13 DISTRIBUTION BOARDS COUNTRY-SPECIFIC DISTRIBUTION BOARDS French standard protected flush-mounting enclosures - White RAL ( ) Enclosures with no door Enclosures equipped with terminal block With no door - walls with knockout elements - IP 30 External Terminal blocks supplied No. modules dimensions L Live - no. holes per sect. (mm EN ) N Neutral - no. holes per sect. (mm (17.5 mm) ) Earth - no. holes per sect. (mm 2 ) GW x 225 x 93.5 (6x16) + (7x10) 8 L (16) + (10) 26 GW x 350 x 93.5 N (16) + (10) (13x2) (116) + (13x10) L (3x16) + (x10) 39 GW x 75 x 93.5 N (3x16) + (x10) (13x3) (116) + (13x10) L (3 x16) + (x10) 52 GW x 600 x 93.5 N (3x16) + (x10) 2 (13x) [(1x25) + (7x16) + (9x10)] ACCESSORIES SUPPLIED: Module masks, circuit labels with self-adhesive symbols, instructions sheet. Enclosures with blank door Enclosures equipped with terminal block With blank door - walls with knockout elements - IP 0 External Terminal blocks supplied No. modules dimensions L Live - no. holes per sect. (mm EN ) N Neutral - no. holes per sect. (mm (17.5 mm) ) Earth - no. holes per sect. (mm 2 ) NEW GW x 225 x 93.5 (6x16) + (7x10) 8 L (16) + (10) 26 NEW GW x 350 x 93.5 N (16) + (10) (13x2) (116) + (13x10) L (3x16) + (x10) 39 NEW GW x 75 x 93.5 N (3x16) + (x10) (13x3) (116) + (13x10) L (3x16) + (x10) 52 NEW GW x 600 x 93.5 N (3x16) + (x10) 2 (13x) [(1x25) + (7x16) + (9x10)] ACCESSORIES SUPPLIED: Module masks, circuit labels with self-adhesive symbols, instructions sheet. Enclosures with transparent door Technical sheets: pages Dimensions: pages Enclosures equipped with terminal block With transparent door - walls with knockout elements - IP 0 External Terminal blocks supplied No. modules dimensions L Live - no. holes per sect. (mm EN ) N Neutral - no. holes per sect. (mm (17.5 mm) ) Earth - no. holes per sect. (mm 2 ) NEW GW x 225 x 93.5 (6x16) + (7x10) 8 L (16) + (10) 26 NEW GW x 350 x 93.5 N (16) + (10) (13x2) (116) + (13x10) L (3x16) + (x10) 39 NEW GW x 75 x 93.5 N (3x16) + (x10) (13x3) (116) + (13x10) L (3x16) + (x10) 52 NEW GW x 600 x 93.5 N (3x16) + (x10) 2 (13x) [(1x25) + (7x16) + (9x10)] ACCESSORIES SUPPLIED: Module masks, circuit labels with self-adhesive symbols, instructions sheet. 56

14 Supporting bases for subscriber connection devices - BLU FARE - White RAL ( ) Bases for switch with no door Supporting bases for the EDF connecting switch - sealable With no door DISTRIBUTION BOARDS Depth GW x 225 x 3.5 GW x 225 x 58.5 ACCESSORIES SUPPLIED: Switch fixing screws, instructions sheet, screw caps for sealing. With the enclosures they permit making the subscriber boards. Bases for switch with blank door Supporting bases for the EDF connecting switch - sealable With blank door Depth NEW GW x 225 x 3.5 NEW GW x 225 x 58.5 ACCESSORIES SUPPLIED: Switch fixing screws, instructions sheet, screw caps for sealing. With the enclosures they permit making the subscriber boards. Bases for switch with transparent door Supporting bases for the EDF connecting switch - sealable With transparent door Depth NEW GW x 225 x 3.5 NEW GW x 225 x 58.5 ACCESSORIES SUPPLIED: Switch fixing screws, instructions sheet, screw caps for sealing. With the enclosures they permit making the subscriber boards. 57

15 DISTRIBUTION BOARDS COUNTRY-SPECIFIC DISTRIBUTION BOARDS Supporting bases for subscriber connection devices - White RAL ( ) Bases for switch and meter with no door Supporting bases for the EDF connecting switch and meter - sealable With no door Depth GW x 225 x 7 GW x 225 x 62 ACCESSORIES SUPPLIED: Switch fixing screws, instructions sheet, 2 cables sect. 25 mm 2 to connect the enclosure with the switch. With the enclosures they permit making the subscriber boards. Bases for switch and meter with blank door Supporting bases for the EDF connecting switch and meter - sealable With blank door Depth NEW GW x 225 x 7 NEW GW x 225 x 62 ACCESSORIES SUPPLIED: Switch fixing screws, instructions sheet, 2 cables sect. 25 mm 2 to connect the enclosure with the switch. With the enclosures they permit making the subscriber boards. Bases for switch and meter with transparent door NEW Supporting bases for the EDF connecting switch and meter - sealable With transparent door GW x 225 x 7 GW x 225 x 62 NEW ACCESSORIES SUPPLIED: Depth Switch fixing screws, instructions sheet, 2 cables sect. 25 mm 2 to connect the enclosure with the switch. With the enclosures they permit making the subscriber boards. Enclosure for cable service distribution - White RAL IP 0 - ( ) Enclosure for cable services Enclosure for cable service devices (T.R.I.) equipped with 2 rails EN and earth terminal block No. modules Terminal block EN supplied (17.5 mm) no. holes x sect. (mm 2 ) GW (13 x 2) 8 x 16 mm 2 ACCESSORIES SUPPLIED: Insulating back-mounting plate. For cable distribution of signal lines (television, telephone, wire broadcasting). ( ) Full insulation to EN Standard, obtainable with the screw caps GW 622 and the insulating back-mounting plates. Technical sheets: pages Dimensions: pages

16 Complementary installation and coupling items Modular spacers Set of modular spacers for enclosures, bases, and subscriber boards (*) Thickness 50 mm - Clip assembly - White RAL 9016 DISTRIBUTION BOARDS Suited to enclosure 13 mod. - 1 row GW x 225 x 50 supporting bases 8 cable services enclosure GW x 350 x 50 enclosure 26 mod. - 2 rows GW x 75 x 50 enclosure 39 mod. - 3 rows GW x 600 x 50 enclosure 52 mod. - rows 2 ACCESSORIES SUPPLIED:Screws for fixing enclosures and bases, instructions sheet. SPECIFIC ACCESSORIES SUPPLIED: GW with 1 pair of couplings GW 0 56 to make subscriber boards. To increase the internal cable passage space CHARACTERISTICS: (*) To make the spacers for subscriber boards, use the spacer GW together with the enclosure spacer. Couplings for vertical and horizontal combinations Back-mounting plates for enclosures and spacers Back-mounting plate for bases Pair of couplings for vertical and horizontal combinations between enclosures, bases and spacers Type of catch GW 0 56 Clip 20 Insulating back-mounting plates for surface-mounting enclosures and spacer sets. Sliding fixing on rail For spacer enclosures GW x 216 x 2 13 mod. - 1 row 8 GW x 31 x 2 26 mod. - 2 rows GW x 66 x 2 39 mod. - 3 rows GW x 591 x 2 52 mod. - rows 2 To make combined compositions and subscriber boards. To obtain full insulation of surface-mounting enclosures. Insulating back-mounting plate for supporting bases. Fixing to wall with screws. GW x 219 x 2 8 To obtain full insulation of supporting bases for devices. Complementary wiring items Terminal block 3P + N Three-phase + neutral insulated terminal block for French standard modular enclosures Nominal current (In) Connecting capacity per pole No. holes x sect. (mm 2 ) L1 (2 x 16) + (2 x 10) GW A L2 (2 x 16) + (2 x 10) L3 (2 x 16) + (2 x 10) 20 N (6 x 16) + (7 x 10) CHARACTERISTICS: Clip and screw fixing. 59

17 DISTRIBUTION BOARDS COUNTRY-SPECIFIC DISTRIBUTION BOARDS Complementary finishing items Blanking doors for enclosures Blanking doors with frames to finish French standard modular enclosures - White RAL IP 0 For enclosures GW mod. - 1 row 8 GW mod. - 2 rows GW mod. - 3 rows GW mod. - rows 2 CHARACTERISTICS: They permit raising the protection rating of enclosures from IP 30 to IP 0. They are secured with the back/front fixing screws of the enclosures. Fitted to accommodate the security cylinder lock GW Transparent doors for enclosures Smoked transparent doors with frames to finish French standard modular enclosures - White RAL IP 0 For enclosures GW mod. - 1 row 8 GW mod. - 2 rows GW mod. - 3 rows GW mod. - rows 2 CHARACTERISTICS: They permit raising the protection rating of enclosures from IP 30 to IP 0. They are secured with the back/front fixing screws of the enclosures. Fitted to accommodate the security cylinder lock GW Blanking and transparent doors for bases Complementary flush-mounting installation items Doors with frames to finish supporting bases. Clip fixing - White RAL 9016 frames - IP 0 For supporting base dimensions L x H Door colour GW 0 51 White RAL 9016 blanking 250 x 225 GW 0 52 Smoked transparent CHARACTERISTICS: Fitted to accommodate the security cylinder lock GW Back-mounting boxes for flush-mounting Metal back-mounting boxes for flush-mounting installations of French standard modular enclosures and subscriber boards Depth 110 mm Suited to GW x 80 x 110 enclosures up to 26 mod. - 2 rows subscriber board 13 mod. 1 GW x 610 x 110 enclosures up to 39 mod. - 3 rows subscriber board 26 mod. 1 GW x 730 x 110 enclosures up to 52 mod. - rows subscriber board 39 mod. 1 GW x 860 x 110 subscriber board 52 mod. 1 Doors for back-mounting boxes Technical sheets: pages Dimensions: pages Metal blanking doors complete with finishing frames for back-mounting flush boxes - White RAL 9016 For back-mounting boxes dimensions L x H GW x 50 x x 80 1 GW x 670 x x GW x 790 x x GW x 920 x x ACCESSORIES SUPPLIED: Screws fixing to back-mounting boxes. 60

18 Decorative protected surface-mounting enclosures, British Standard - White RAL IP 30 Smoked transparent door Enclosures fitted to house terminal blocks and combs for connecting modular devices. Smoked transparent door - Walls with knockout elements DISTRIBUTION BOARDS No. modules EN (17.5 mm) External dimensions Installable terminal blocks N Neutral - no. holes per sect..(mm 2 ) Earth - no. holes per sect. (mm 2 ) GW x 225 x 105 N (25) + (x16) (3x25) + (x16) GW x 225 x 105 N (25) + (x16) (3x25) + (x16) GW x 225 x 105 N 2 x [(25) + (x16)] (x25) + (7x16) GW x 225 x 105 N 2 x [(25) + (7x16)] (3x25) + (116) N (x25) + (7x16) GW x 225 x 105 N (25) + (7x16) (3x25) + (16x16) Complementary wiring items ACCESSORIES SUPPLIED: Mask covers, saddle for neutral terminal block connection, caps for comb GW 0 851, screw caps for double insulation, circuit labels, shield IP XXB for connecting live parts. CHARACTERISTICS: Walls with knockout elements fitted for trunking sized from 25x16 mm to 0x0 mm. Doors fitted to accommodate security cylinder lock GW Connecting combs Terminal blocks Neutral cable Set of cables for twin circuits Technical sheets: pages Dimensions: page 23 Single-pole comb for connecting modular devices No. modules Nominal No. connections EN current (17.5 mm) In (A) Input Outputs GW CHARACTERISTICS: Specific for British Standard GEWISS enclosures. Neutral and earth terminal blocks with support for British Standard enclosures. Fixing with screws - IP 00 Neutral terminal blocks Earth terminal blocks no. holes x sect. (mm 2 ) no. holes x sect. (mm 2 ) For enclosures no. modules EN (17.5 mm) GW (25) + (x16) (3x25) + (x16) GW [(25) + (x16)] (x25) + (7x16) GW [(25) + (7x16)] (3x25) + (116) 1 20 (x25) + (7x16) GW 0 86 (3x25) + (16x16) (25) + (7x16) STANDARD ACCESSORIES SUPPLIED: Fixing screws. SPECIFIC ACCESSORIES SUPPLIED: GW 0 862, GW 0 863, GW 0 86 with bare copper saddle to connect neutral terminal blocks. CHARACTERISTICS: Earth terminal blocks with disconnectable input. Insulated copper cable to connect neutral terminal block with the main switch Nominal Pack/ Colour section mm 2 GW Black 10/100 CHARACTERISTICS: Cable with stripped and fitted ends. Set of 3 insulated copper cables to wire enclosures in installations with a double circuit Description Pack/ Type No. x sect. (mm 2 ) Colour GW Live 1 x 16 Red Neutral 2 x 16 Black 1/50 CHARACTERISTICS: Cable with stripped and fitted ends. 61

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids.

2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids. DOMINO Series. CONSUMER UNITS AND REFERENCE STANDARDS DIMENSIONS EN 60670- Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part : general requirements.

More information

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Cabinets G  integrated in upright Handle strip in side panel Easy solution for shortened doors Overview... 0 Cabinets... 1 Cabinets Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 Subracks/ 19" chassis... 6 02002002 Front panels,

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

Main Catalogue. Edition 23, chapter minirack: Phase-out product!

Main Catalogue. Edition 23, chapter minirack: Phase-out product! Edition 23, chapter minirack: Phase-out product! Overview... 0 Cabinets... 1 G Cabinets G Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases...

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth

More information

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN PANEL BOARDS ADDRESSED TO HAZARDOUS AREAS - PART THREE July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Redline Unibis : the solution Circuit protection

Redline Unibis : the solution Circuit protection 2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3.

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3. Overview..... 0 NOVASTAR Cabinets NOVASTAR Cabinets...... 1 Wall mounted cases........ 2 Accessories for cabinets and wall mounted cases 3 Climate control 4 Desk-top cases 5 Subracks/ 19" chassis... 6

More information

RIMA OFFICIAL CATALOGUE CATALOGUE TP

RIMA OFFICIAL CATALOGUE CATALOGUE TP RAIL BRAKES RIMA OFFICIAL CATALOGUE UE 1 / 1 4 FEBRUARY 2013 CATALOGUE TP UE 2 / 1 4 DescriPt Ption Utilization and functioning Rail brakes, suitable for medium forces from 20 to 300 kn (securing cranes

More information

What You Need to Get Started INSTALLATION GUIDE

What You Need to Get Started INSTALLATION GUIDE INSTALLATION GUIDE SBS-96F SHIELDED BACKSHELL This guide describes how to assemble and install the SBS-96F shielded backshell with low-voltage SCXI modules, VXI-DAQ modules, or low-voltage TBX terminal

More information

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

32 Input AC Block I/O Module

32 Input AC Block I/O Module Input AC Module Cat. No. 79-A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to flow through

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Rotary Switches AC09, 16 and 32

Rotary Switches AC09, 16 and 32 09, 16 and 32 igital code output type escription FUJI series rotary switches offer a wide choice of output codes. They feature sliding u-flashed contacts for high contact reliability. Inhibitor and parity

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

ZUCCHINI MR - MEDIUM RATING BUSBAR

ZUCCHINI MR - MEDIUM RATING BUSBAR ZUCCHINI MR - MEDIUM RATING BUSBAR Available in sizes from 0 to 000 A, MR (medium rating) busbar is ideal for power distribution in medium to large installations and rising mains in commercial buildings.

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P

TeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

Analogue Meters CQ2x07 series

Analogue Meters CQ2x07 series Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement

More information

Commercial Generator Parts Catalog. PROTEC Series

Commercial Generator Parts Catalog. PROTEC Series Commercial Generator Parts Catalog PROTEC Series YD ÁÁ ÁÁ To avoid errors or delay in filling your parts order, always give the MODEL, SPEC NO. and SERIAL NO. from the Onan nameplate. For handy reference,

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

TeSys enclosed starters 2

TeSys enclosed starters 2 Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS Manufacturer: Model: Evaluation Performed By: INTRODUCTION: This checklist will enable the user to make an objective appraisal of the condition of the equipment. Given the variety and complexity of the

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018 Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers

More information

Product description. Compact Modules. Characteristic features. Further highlights

Product description. Compact Modules. Characteristic features. Further highlights 4 Compact Modules Product description Characteristic features Five fine-tuned sizes based on a compact precision aluminum profile with two integrated pre-tensioned ball rail systems Identical external

More information

SHELVING SYSTEM SYSTEM AR

SHELVING SYSTEM SYSTEM AR F34 SHELVING SYSTEM SERIES F R SFETY SFETY shelving depth DOULE LOCKING SFETY MECHNISM The shelving system is fitted with a double locking system to allow only one shelf to be pulled out at one time. The

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 NO. ISSUED: REVISED: 71193 OCT. 2, 2001 JAN. 27, 2003 HOSHIZAKI STACKABLE CRESCENT CUBER MODELS KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3 PARTS LIST KM-1600SWH L-0 June, 2001 M-0 Feb., 2002 M-1 Feb.,

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

Internal Components Forms of Separation

Internal Components Forms of Separation IEC 60439-1 One or more of the following conditions can be attained by dividing ASSEMBLIES by means of partitions or barriers (metallic or non-metallic) into separate compartments or enclosed protected

More information

Cabinets Novastar OVERVIEW MAIN KATALOG LIGHT - SLIM - ROBUST. Cabinets Wall mounted cases... 2

Cabinets Novastar OVERVIEW MAIN KATALOG LIGHT - SLIM - ROBUST. Cabinets Wall mounted cases... 2 Novastar NovastarMain CataloguePart number in bold face type: ready for despatch within 2 working dayspart number in normal type: ready for despatch within 10 working days Cabinets Novastar OVERVIEW MAIN

More information

Masterpact. Installation recommendations

Masterpact. Installation recommendations 90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

ORTHOBLOC 3000 Drive systems Maintenance

ORTHOBLOC 3000 Drive systems Maintenance 15 en 284 261 282 113 130 120 061 002 264 193 099 001 25 063 65 119 112 133 252 254 1 115 118 04 ORTHOBLOC 3000 Maintenance NOTE LEROY-SOMER reserves the right to modify the characteristics of its products

More information

5SP and 5SY Supplementary Protection UL 1077

5SP and 5SY Supplementary Protection UL 1077 Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

Pushbutton Units and Indicator Lights

Pushbutton Units and Indicator Lights Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded

More information

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m T 2.2/1/B/1 Swirl Diffuser Type SDW recommended for room heights from approx. 2.60... 4.00 m TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44(0) 1842 54545 Telefax +44(0) 1842 63051 e-mail

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Device Specifications

Device Specifications Manual Device Specifications PART NUMBER LCGATEWAY ELECTRICAL The Lightcloud Gateway is designed to be hard-wired to AC power by a qualified electrician. INPUT 120-277 VAC, 50/60 Hz 60-45mA BATTERY Li-ion

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

Quantum. Quantum light body. Quantum masks

Quantum. Quantum light body. Quantum masks Quantum Quantum light body Registered patent Quantum masks Quantum posts Quantum is a new range of recessed lighting fittings for outdoors planned to contain very efficient power leds. new innovative concept

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air Ceiling Square ceiling air diffuser for supply air and extract air Quick facts Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed

More information

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of

More information

LED light engines LED linear / area

LED light engines LED linear / area Module LLE G2 55mm 4lm ADV Modules LLE ADVANCED Product description Ideal for linear and panel lights LED system solution with outstanding system efficiency up to 165 lm/w, consisting of linear LED modules

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Requirements to perform accurate dielectric material analysis

Requirements to perform accurate dielectric material analysis Requirements to perform accurate dielectric material analysis By Britta Pfeiffer 2017 by OMICRON Lab V1.0 Visit www.omicron-lab.com for more information. Contact support@omicron-lab.com for technical support.

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37850 Application: HONDA 300 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

Wires & Cables. Wires & Cables FEB 2018 LP : 05. A Ratna Ganga Group Company. Toll Free No. : WIRES & CABLES PRICE LIST CUM CATALOGUE

Wires & Cables. Wires & Cables FEB 2018 LP : 05. A Ratna Ganga Group Company. Toll Free No. : WIRES & CABLES PRICE LIST CUM CATALOGUE Terms: All Product are ISI marked Price are subject to change without prior notice. All applicable GST taxes will be charged extra. Any dispute if arises are subject to Delhi Jurisdiction only. As per

More information

Lines 176 MAESTRO 1.0

Lines 176 MAESTRO 1.0 176 MAESTRO 1.0 FerroWine - Treviso (Italy) 177 Range Index Xenia Xenia Xenia RGB 186 190 Stiff Stiff Stiff RGB Stiff Strip 196 200 202 Lafina Lafina Lafina_F Ice-Cut Ice-Cut 208 209 2 Reika Reika_1 Reika_2

More information

3D Drawing - CARIF 260 BSA

3D Drawing - CARIF 260 BSA D Drawing - CARIF 0 BSA DRAWING CODE DRAWING NAME NUMBER ASS000 Basement ASS00 Vice Base ASS00 Vice A ASS00B Vice B ASS00 Frame A ASS00B Frame B ASS000 Frame Cylinder A ASS000B Frame Cylinder B ASS000

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

FORMWORK SAVINGS ADAPTABILITY LIGHT WEIGHT ECONOMICAL ALUMINIUM SLAB FORMWORK. BV Cert

FORMWORK SAVINGS ADAPTABILITY LIGHT WEIGHT ECONOMICAL ALUMINIUM SLAB FORMWORK. BV Cert FORMWORK SAVINGS ADAPTABILITY LIGHT WEIGHT ECONOMICAL ALUMINIUM SLAB FORMWORK BV Cert. 6150814 Dalphi Economical aluminium slab formwork 2 FORMWORK The economical, high-performance Dalphi floor formwork

More information

XL-550. Liste de pièces Lista de Piezas Parts List

XL-550. Liste de pièces Lista de Piezas Parts List SINGER is the exclusive trademark of The Singer Company S.à.r.l or its Affi liates. 0 The Singer Company Limited S.à.r.l or its Affi liates. All rights reseved. XL-0 Liste de pièces Lista de Piezas Parts

More information

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour

More information