TeSys contactors From 115 to 2750 A
|
|
- Justin Bell
- 5 years ago
- Views:
Transcription
1 Selection guide TeSys contactors From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification, transformers, normal-standby Rated operational current le max. AC- (Ue y 0 V) Ie max. AC- (q y 0 C) A 0 A A A A 0 A 00 A 00 A 00 A 0 A A A 0 A 00 A 00 A 00 A Rated operational voltage 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V Number of poles or or or or or or, or, or Rated operational power in category AC- 0/0 V 0 kw 0 kw kw kw kw 00 kw 0 kw kw 0/00 V kw kw 0 kw 0 kw kw 0 kw 00 kw 0 kw V kw 0 kw 00 kw 0 kw 0 kw 0 kw 0 kw 0 kw 0 V kw 0 kw 00 kw 0 kw 0 kw 00 kw 0 kw kw 00 V kw 0 kw 0 kw kw 0 kw 00 kw kw kw 0/0 V 0 kw 00 kw 0 kw kw 0 kw 0 kw 0 kw kw Add-on auxiliary contact blocks 000 V kw kw 00 kw 00 kw kw 0 kw kw kw Front mounting, identical to those used on LC D contactors (contacts: instantaneous LA DNpp, time delay LA DT or LA DR, dust and damp protected LA DX or DY or DZ) Associated thermal overload relays and controllers Manual-auto Electronic LR F TeSys T Interfaces Specific LA FWB Universal With or without, depending on the control circuit Contactor type LC F LC F0 LC F LC F LC F LC F0 LC F00 LC F00 Reversing contactor type LC F LC F0 LC F LC F LC F For customer assembly Pages Contactors / and / / and / Reversing contactors / and / / to / 0 /0
2 0 A 0 A 00 A 0 A 000 A 00 A 00 A 000 A 00 A 000 A 0 A 00 A 00 A 00 A 00 A 0 A 000 A 0 A 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V 000 V, or or to to to to 00 KW 0 kw 0 kw 0 kw 0 kw kw 00 kw kw 00 kw 0 kw 00 kw 00 kw 0 kw 00 kw kw kw 0 kw kw 0 kw 00 kw 00 kw 00 kw kw 0 kw 0 kw 0 kw 00 kw 00 kw 00 kw 0 kw 0 kw 00 kw 00 kw 00 kw 00 kw 0 kw kw kw 0 kw 0 kw 0 kw 00 kw 0 kw 0 kw 0 kw 0 kw 0 kw 0 kw 0 kw Front mounting, identical to those used on LC D contactors (contacts: instantaneous LA DNpp, time delay LA DT or LA DR, dust and damp protected LA DX or DY or DZ) LR F LR F TeSys T TeSys T instantaneous contact compositions: N/C + N/O, N/O + N/C, N/O + N/C or N/O LA FWB With or without, depending on the control circuit LC F0 LC F0 LC F00 LC F0 LC F00 LC F00 LC F00 LC BL LC BM LC BP LC BR For customer assembly / and / / and / / to / / 0 /0
3 Characteristics TeSys contactors TeSys F contactors ( to 00 A) Control circuit: a.c. or d.c. Environment Contactor type LC F LC F0 LC F Rated insulation voltage (Ui) Conforming to IEC 0-- V Rated impulse withstand voltage (Uimp) Conforming to VDE 00 gr C V Coil not connected to the power circuit kv Conforming to standards EN 0-, EN 0--, IEC 0-, IEC 0--, JEM 0 Product certifications CSA, UL, BV, GL, DNV, RINA, RMROS, LROS, CCC Degree of protection Conforming to IEC 0 IP X front face with shrouds LA F Conforming to VDE 00 Front face protected against direct finger contact with shrouds LA F Protective treatment Standard version TH Ambient air temperature around the device Storage C Operation C - + Permissible at Uc () C Maximum operating altitude Without derating m 000 Operating positions Without derating (not to be used for LC F0, F00 and F00) With derating Not to be used Apply the following derating coefficients: 0. on the pull-in voltage, 0. on the drop-out voltage and 0. on the operational current in AC- Apply the following derating coefficients:. on the pull-in voltage,. on the drop-out voltage and 0. on the operational current in AC- In either case: neither the making and breaking capacities nor the electrical and mechanical durabilities can be assured. Shock resistance () / sine wave ms Vibration resistance () 00 Hz Contactor open gn gn gn Contactor closed gn gn gn Contactor open gn gn gn Contactor closed gn gn gn () In these conditions, it is recommended that LX F coils be used for contactor sizes F to F. () In the least favourable direction, without change of contact state (coil at Uc). Where higher resistance to mechanical shock is required, select shock-proof contactors. Please consult your Regional Sales Office. 0 Selection : pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /0
4 LC F LC F LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F0 LC F00 LC F00 LC F EN 0-, EN 0--, IEC 0-, IEC 0--, JEM 0 CSA, UL, BV, GL, DNV, RINA, RMROS, LROS, CCC UL, CSA, CSA, CCC, ETL-UL GL, LROS IP 0 front face with shrouds LA F Front face protected against direct finger contact with shrouds LA F TH (not to be used for LC F0, F00, F00 and F00) Not to be used Apply the following derating coefficients: 0. on the pull-in voltage, 0. on the drop-out voltage and 0. on the operational current in AC-. Apply the following derating coefficients:. on the pull-in voltage,. on the drop-out voltage and 0. on the operational current in AC-. In either case: neither the making and breaking capacities nor the electrical and mechanical durabilities can be assured gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn gn. gn gn gn. gn gn gn gn gn gn gn gn gn gn gn gn. gn gn gn gn gn gn 0 /0
5 Characteristics (continued) TeSys contactors TeSys F contactors ( to 00 A) Control circuit: a.c. or d.c. Pole characteristics Contactor type LC F LC F0 LC F LC F LC F Number of poles or or or or or Rated operational current (le)(ue y 0 V) In AC-, q y C A 0 In AC-, q y 0 C A Rated operational voltage Up to V (Ue) Frequency limits Of the operational current () Hz / 00 / 00 / 00 / 00 / 00 Conventional thermal current q y 0 C A Rated making capacity Rated breaking capacity Maximum permissible current No current flowing for previous 0 minutes, at q y 0 C Short-circuit protection by fuses U y 0 V I rms conforming to IEC 0-- A Making current: 0 x I in AC- or x I in AC- I rms conforming to A Making and breaking current: x I in AC- or 0 x I in AC- IEC 0-- For 0 s A For 0 s A For min A For min A For 0 min A Motor circuit (type am) A With thermal overload relay A (type gg) gg fuses A Average impedance per pole At lth and 0 Hz mw Power dissipation per pole for the above operational currents Connection AC- W AC- W Maximum c.s.a. Bar Number of bars Bar mm 0 x x x x x Cable with lug mm Cable with connector mm Bolt diameter mm Ø Ø Ø 0 0 Tightening torque Power circuit connections N.m 0 () Sine wave without interference. Above these values, please consult your Regional Sales Office. () With set of right-angled connectors LA F00 (see page /). () Paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. 0 Selection : pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /0
6 LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F0 LC F00 LC F00 LC F00 or, or, or, or or () / 00 / 00 / 00 / 00 / 00 / 00 / 00 / 00 / 00 / () Making current: 0 x I in AC- or x I in AC- Making current:. x I in AC- Making and breaking current: x I in AC- or 0 x I in AC- Making and breaking current:. x I in AC x 00 () x 00 x 00 () x 000 () x 0 x 0 x 0 x 0 x 00 x 0 x 00 x 00 x 00 x 00 x 0 x 0 x x x x (. with set of right-angled (. with set connectors LA F00) of right-angled connectors LA F0) ( with set of right-angled connectors LA F0) ( with set of right-angled connectors LA F00) 0 /0
7 Characteristics TeSys contactors TeSys F contactors ( to 00 A) Control circuit: a.c. Control circuit characteristics with LX or LX coil Contactor type LC F LC F0 LC F LC F LC F Rated control circuit voltage (Uc) 0 or 0 Hz V 000 Control voltage limits (q y C) 0 or 0 Hz coils Operation 0.. Uc Drop-out Uc 0 00 Hz coils Operation 0.. Uc Drop-out Uc Average consumption at 0 C and at Uc a 0 Hz Inrush 0 Hz coil VA Hz coil VA 0 Cos j Sealed 0 Hz coil VA 0 00 Hz coil VA 0 Cos j a 0 Hz Inrush 0 Hz coil VA Hz coil VA 0 Cos j Sealed 0 Hz coil VA 0 00 Hz coil VA 0 Cos j Heat dissipation W Operating time () Closing "C" ms Opening "O" ms 00 0 Mechanical durability at Uc In millions of operating cycles Maximum operating rate at ambient temperature y C Connection Flexible cable without cable end Flexible cable with cable end In operating cycles per hour Min/max c.s.a. or conductors mm / / / / / conductor mm / / / / / conductors mm /. /. /. /. /. Solid cable or conductors mm / / / / / without cable end Tightening torque N.m..... Mechanical latching Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. () The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. () Control circuit characteristics with LX coil. 0 Selection : pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /0
8 LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F0 LC F00 LC F00 LC F () 0 00 () 0 00 () 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc Uc Uc Uc Uc Uc Uc Uc Uc Uc x 0 x x x Min/max c.s.a. / / / / / / / / / / / / / / / / / / / / /. /. /. /. /. /. /. /. /. /. / / / / / / / / / / Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. 0 /
9 Characteristics TeSys contactors TeSys F contactors ( to 00 A) Control circuit: d.c. Control circuit characteristics with LX coil Contactor type LC F LC F0 LC F LC F LC F Rated control circuit voltage c V (Uc) Control voltage limits Operation 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc (q y C) Drop-out Uc Uc Uc Uc Uc Average consumption at 0 C and at Uc Average operating time at Uc () c Inrush W Sealed W.. Closing "C" ms Opening "O" ms Note: The arcing time depends on the circuit switched by the poles. For all normal -phase applications, the arcing time is less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Mechanical durability at Uc In millions of operating cycles Maximum operating rate at ambient temperature y C Cabling Flexible cable without cable end In operating cycles per hour Min/max c.s.a. conductor mm / / / / / conductors mm / / / / / Flexible cable conductor mm / / / / / with cable end conductors mm /. /. /. /. /. Solid cable without cable end conductor mm / / / / / conductors mm / / / / / Tightening torque N.m..... Mechanical latching Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. () The operating times depend on the type of contactor electromagnet and its control mode. The closing time "C" is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time "O" is measured from the moment the coil supply is switched off to the moment the main poles separate. 0 Selection : pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /
10 LC F0 LC F00 LC F00 LC F0 LC F0 LC F00 LC F0 LC F00 LC F00 LC F Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc 0.. Uc Uc Uc Uc Uc Uc Uc Uc Uc Uc Uc x x Note: The arcing time depends on the circuit switched by the poles. For all normal -phase applications. the arcing time is less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time Min/max c.s.a. / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /. /. /. /. /. /. /. /. /. /. / / / / / / / / / / / / / / / / / / / / Mechanical latch blocks LA DK must not be fitted on LC F contactors. For similar type of operation, use magnetic latching contactors CR F. See pages /0 to /. 0 /
11 References TeSys contactors TeSys F contactors for motor control in utilisation category AC- ( to 00 A) Control circuit: a.c. or d.c. 00 LC F -pole contactors Standard power ratings of -phase motors 0-0 Hz in category AC- Rated operational current in AC- 0 V 0 V 0 V 0 V 0 V 00 V V 0 V 00 V 0 V 000 V up to Basic reference, to be completed by adding the voltage code () Screw fixing, cabling () Weight kw kw kw kw kw kw kw A kg 0 0 LC Fpp LC F0pp LC Fpp LC Fpp LC Fpp LC F0pp LC F00pp LC F00pp LC F0pp.00 LC F LC F0pp LC F00pp.0 Note: auxiliary contact blocks, modules and accessories: see pages / to /. () Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, except on contactors LC F0 (see page /). () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts a LC F F 0 Hz (coil LX) B E F FE M P U Q V N 0 Hz (coil LX) E F G L M U Q R 0 00 Hz (coil LX) E F FE G L M P U Q V N R LC F F Hz (coil LX) B E F FE G L M P U Q V N R LC F00 F Hz (coil LX) E F FE G () L M P U Q V N R LC F Hz (coil LX) F FE F L M P U Q V N R LC F Hz (coil LX) () FW FW FW MW MW MW QW QW QW Volts c LC F F0 (coil LX F) BD ED FD GD MD MD UD RD LC F00 F0 (coil LX F) ED FD GD MD UD RD LC F0 (coil LX F) FD GD MD UD RD LC F00 (coil LX F) FW FW MW MW QW () F for LC F0. () Coil LX Fpp + rectifier DRTEpp. 0 Selection : pages / to / References : pages /0 and / Dimensions : pages /0 to / Schemes : page / /
12 References (continued) TeSys contactors TeSys F contactors for control in category AC-, (00 to 00 A ) Control circuit: a.c. or d.c. 0, or -pole contactors Maximum current in AC- (θ y 0 C) Number of poles Basic reference, to be completed by adding the voltage code () Screw fixing, cabling () Weight A kg 00 LC Fpp.0 LC F LC Fpp.0 0 LC F0pp.0 LC F0pp.0 0 LC Fpp.0 LC Fpp.0 LC Fpp.0 LC Fpp.0 0 LC F00 0 LC Fpp.0 LC Fpp.0 00 LC F0pp.00 LC F0pp LC F00pp.000 LC F00pp.00 LC F00pp 0.00 LC F0 00 LC F00pp.0 LC F00pp.0 LC F00pp LC F0pp.00 LC F0pp.00 LC F0pp.00 0 LC F0pp LC F00pp.000 LC F00 00 LC F0pp.00 LC F0pp LC F00pp () LC F00pp.000 LC F00 Note: auxiliary contact blocks, modules and accessories: see pages / to /. () Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately (except LC F0, LC F0, LC F00, LC F00 and LC F00), see page /. () Standard control circuit voltages, see previous page. () With set of right-angled connectors LA F00 (see page /). 0 Selection : pages / to / References : pages / and / Dimensions : pages /0 to / Schemes : page / /
13 References TeSys contactors TeSys F reversing contactors for motor control in utilisation category AC- ( to A), pre-assembled Control circuit: a.c. or d.c. DB0 LC F -pole reversing contactors (horizontally mounted) () Pre-wired power connections Standard power ratings of -phase motors 0/0 Hz in category AC- Operational current in AC- 0 V 0 V 0 V 0 V 0 V 00 V V 0 V 00 V 0 V 000 V up to Maximum operational voltage Contactors supplied without coil () Complete reference Fixing, cabling () Weight kw kw kw kw kw kw kw A V kg LC F LC F LC F LC F LC F.0 Accessories (to be ordered separately) Description For reversing contactors Quantity required Power terminal protection shrouds Reference Weight kg LC F LA F0 0.0 LC F0, F LA F0 0.0 LC F, F LA F0 0.0 Auxiliary contact blocks and add-on modules See pages / to / () Fitted with a mechanical interlock without electrical interlocking. Order separately auxiliary contact blocks LAD Np to obtain electrical interlocking between the contactors, see page / For accessories, see pages / to /. () Coils to be ordered separately: - a.c. supply, see pages /0 and /, - d.c. supply, see page /. () Screw fixing. Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, see above. 0 Selection : pages / to / / Dimensions: pages / to /0 Schemes: page /
14 References (continued) TeSys contactors TeSys F changeover contactor pairs for control in utilisation category AC- (00 to 0 A), pre-assembled Control circuit: a.c. or d.c. 0 LC F -pole changeover contactor pairs (horizontally mounted) () Pre-wired power connections Utilisation category AC- Maximum Contactors Weight Non inductive loads Maximum operational current q < 0 C operational voltage supplied without coil () Complete reference Fixing, cabling () A V kg LC F LC F LC F LC F LC F.0 Accessories (to be ordered separately) Description For changeover pairs Quantity required Power terminal protection shrouds Reference Weight kg LC F LA F0 0.0 LC F0, F LA F0 0.0 LC F, F LA F0 0.0 Auxiliary contact blocks and add-on modules See pages / to / () Fitted with a mechanical interlock without electrical interlocking. Order separately auxiliary contact blocks LAD Np to obtain electrical interlocking between the contactors, see page / For accessories, see pages / to /. () Coils to be ordered separately: - a.c. supply, see pages /0 and /, - d.c. supply, see page /. () Screw fixing. Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, see above. 0 Selection : pages / to / Dimensions: pages / to /0 Schemes: page / /
15 Combinations TeSys contactors TeSys F reversing contactors and changeover contactor pairs Components for assembling -pole reversing contactors and changeover contactor pairs, for customer assembly Horizontally mounted Mechanical interlocks Sets of power connections Reversers assembled using contactors of identical rating, Reversing contactors -pole changeover contactor pairs () type : LA Fp0 () LA Fppp () LA Fppp () LC F LC F0 LC F LC F LC F LC F0 LC F00 LC F00 LC F0 LC F00 A A L L L U V W A A A A /L /L /L L /L L /L L /L A A Vertically mounted Reversers assembled using contactors of identical rating, type : LC F LC F0 LC F LC F LC F LC F0 LC F00 LC F00 LC F0 LC F00 Reversers assembled using contactors of different ratings, see page /0 Mechanical interlocks LA FFF LA FGG LA FHH LA FJJ LA FKK LA FLL LC F0 LA FX0 () For -pole changeover contactor pairs, see pages /0 and /. () Complete references: see page /. 0 /
16 References TeSys contactors TeSys F reversing contactors and changeover pairs Components for assembling -pole reversing contactors and changeover contactor pairs, for customer assembly Control circuit: a.c. or d.c. Reversers assembled using contactors of identical rating Contactor type Set of power connections Mechanical interlock () Reference Weight kg Kit reference Weight kg For assembly of -pole reversing contactors for motor control Horizontally mounted LC F LA FF 0.00 LA FF LC F0 LA F LA FF LC F LA FG 0.0 LA FG LC F LA F.00 LA FG LC F LA FH.00 LA FJ0 0.0 LC F0 LA FJ.00 LA FJ0 0.0 LC F00 LA FJ.00 LA FJ0 0.0 LC F00 LA FK.0 LA FJ0 0.0 LC F0 or F00 LA FL.00 LA FL0 0.0 Vertically mounted LC F or F0 () LA FFF 0. LC F () LA FGG 0.0 LC F () LA FGG 0.0 LC F or F0 () LA FHH.00 LC F00 () LA FJJ.00 LC F00 () LA FKK.00 LC F0 or F00 () LA FLL.0 LC F0 () LA FX0 ().00 For assembly of -pole changeover contactor pairs () Horizontally mounted LC F LA FF 0.0 LA FF LC F0 LA F0 0.0 LA FF LC F LA FG 0.0 LA FG LC F LA F.00 LA FG LC F LA FH.00 LA FJ0 0.0 LC F0 LA FJ.00 LA FJ0 0.0 LC F00 LA FJ.00 LA FJ0 0.0 LC F00 LA FK.00 LA FJ0 0.0 LC F0 or F00 LA FL.00 LA FL0 0.0 Vertically mounted LC F or F0 () LA FFF 0. LC F () LA FGG 0.0 LC F () LA FGG 0.0 LC F or F0 () LA FHH.00 LC F00 () LA FJJ.00 LC F00 () LA FKK.00 LC F0 or F00 () LA FLL.0 LC F0 () LA FX0 ().00 () To order the contactors: see pages / and /. For the auxiliary contact blocks LAD Np required to obtain electrical interlocking between the contactors, see page / For accessories, see pages / to /. () With the exception of contactors LC F0, all power connections are to be made by the customer. () Double mechanical interlock mechanism with interlock connecting rods and power connecting links. () For assembly of -pole changeover contactor pairs, see pages /0 and /. 0 Selection : pages / to / Dimensions: pages / to /0 Schemes: page / /
17 Combinations TeSys contactors TeSys F changeover contactor pairs Components for assembling and -pole changeover contactor pairs, for customer assembly Horizontally mounted Mechanical interlocks Sets of power connections Contactor pairs assembled using -pole changeover contactor pairs () contactors of identical rating, type : LC F LC F0 LC F LC F LC F LC F0 LC F00 LC F00 LC F0 LA Fp0 LA Fppp A A N /L /L /L /L L /L L /L L N N A A Vertically mounted Contactor pairs assembled using contactors of identical rating, type : LC F LC F0 LC F LC F LC F LC F0 LC F00 LC F00 LC F0 Mechanical interlocks Assembly A Assembly B Assembly C LA FFF LA FHH LA FX LA FGG LA FJJ LA FKK LA FLL Contactor pairs assembled using contactors of different ratings, type : LC F or F LC F0 or F0 LC F or F LC F or F LC F or F LC F0 or F0 LC F00 or F00 LC F00 or F00 LC F0 or F0 LC F00 Assembly A Assembly B Assembly C LA FGF LA FHF, LA FHG LA FJF, LA FJG LA FKF, LA FKG LA FLF, LA FLG LA FJH LA FKH, LA FKJ LA FLH, LA FLJ and LA FLK Contactor pairs assembled using contactors of identical or different ratings, type : LC F or F LC F0 or F0 LC F or F LC F or F LC F or F LC F0 or F0 LC F00 or F00 LC F00 or F00 LC F0 or F0 LC F00 LA Fppp : see pages / and /. 0 () For -pole changeover contactor pairs, see pages / and /. Important: the contactor ratings must be in decreasing size from top to bottom. /0
18 References TeSys contactors TeSys F changeover contactor pairs Components for assembling and -pole changeover contactor pairs, for customer assembly Control circuit: a.c. or d.c. Contactor pairs assembled using contactors of identical rating For assembly of -pole changeover contactor pairs () Contactor type () Set of power connections Reference Weight kg Mechanical interlock Kit reference Weight kg Horizontally mounted LC F LA FF 0.0 LA FF LC F0 LA F0 0.0 LA FF LC F LA FG 0.0 LA FG LC F LA F.00 LA FG LC F LA FH.00 LA FJ0 0.0 LC F0 LA FJ.00 LA FJ0 0.0 LC F00 LA FJ.00 LA FJ0 0.0 LC F00 LA FK.00 LA FJ0 0.0 LC F0 LA FL.00 LA FL0 0.0 Vertically mounted LC F or F0 () LA FFF 0. LC F () LA FGG 0.0 LC F () LA FGG 0.0 LC F or F0 () LA FHH.00 LC F00 () LA FJJ.00 LC F00 () LA FKK.00 LC F0 () LA FLL.0 LC F0 () LA FX ().00 Contactor pairs assembled using contactors of different ratings For assembly of or -pole changeover contactor pairs Contactor type() Mechanical interlock At bottom At top Kit reference Weight kg Vertically mounted LC F or F or LC F0 or F0 LC F or F or LC F or F LC F or F or LC F0 or F0 LC F or F LA FGF 0.0 LC F or F LA FGF 0.0 LC F or F LA FHF 0.0 LC F0 or F0 LA FHF 0.0 LC F00 or F00 LA FJF 0.0 LC F00 or F00 LA FKF 0.0 LC F0, F0 or F00 LA FLF 0.0 LC F or F LA FHG 0.0 LC F0 or F0 LA FHG 0.0 LC F00 or F00 LA FJG 0.0 LC F00 or F00 LA FKG 0.0 LC F0, F0 or F00 LA FLG 0.0 LC F00 or F00 LA FJH.0 LC F00 or F00 LA FKH.0 LC F0, F0 or F00 LA FLH.0 LC F00 or F00 LC F00 or F00 LA FKJ.00 LC F0 or F0 or F00 LA FLJ.0 LC F00 or F00 LC F0 or F0 or F00 LA FLK.0 For assembly of reversers using contactors, vertically mounted See pages / and /. () For assembly of -pole changeover contactor pairs, see pages / and /0. () To order the contactors: see pages / and /. For the auxiliary contact blocks LAD Np required to obtain electrical interlocking between the contactors, see page /. For accessories, see pages / to /. () All power connections are to be made by the customer. () Double mechanical interlock mechanism with interlock connecting rods and power connecting links. 0 Selection : pages / to / Dimensions: pages / to /0 Schemes: page / /
19 LAD N LAD N, LAD C LAD N0, N0 LC F LAD T, LAD S LAD R LA DX, DY, DZ 0 /
20 References TeSys contactors TeSys F contactors Auxiliary contact blocks Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts Maximum number of blocks per contactor Clip-on mounting Composition Reference Weight kg LAD N LAD N LAD N 0.00 LAD N LAD N LAD N 0.00 LAD N 0.00 LAD N LAD N LAD N 0.00 () LAD C 0.00 With terminal referencing conforming to EN 00 LAD NP 0.00 LAD NG 0.00 LAD NP 0.00 LAD NG 0.00 Instantaneous auxiliary contact blocks for connection by lugs This type of connection is not possible for blocks with contact or blocks with dust and damp protected contacts. For all other instantaneous auxiliary contact blocks, add the figure to the end of the references selected above. Example: LAD N becomes LAD N. Instantaneous auxiliary contact blocks with dust and damp protected contacts Recommended for use in particularly harsh industrial environments Number of contacts Maximum number of blocks per contactor Clip-on mounting Composition Reference Weight kg LA DX () LA DY LA DZ LA DZ 0.00 Time delay auxiliary contact blocks Number of contacts N/O + N/C Maximum number of blocks per contactor Time delay Reference Weight Clip-on mounting Type Range s kg On-delay 0. () LAD T LAD T LAD T () LAD S 0.00 Off-delay 0. () LAD R LAD R LAD R 0.00 () Including N/O + N/C make before break () Device fitted with earth screen continuity terminals. () With extended scale from 0. to 0. s. () With switching time of 0 ms ± ms between opening of the N/C contact and closing of the N/O contact. 0 Presentation : page / Schemes : page / /
21 References TeSys contactors TeSys F contactors Suppressor blocks 0 LA D0 LA Fppp Suppressor blocks RC circuits (resistor-capacitor) b Effective protection for circuits highly sensitive to "high frequency" interference. For use only in cases where the voltage is virtually sinusoidal, i.e. less than % total harmonic distortion. b Voltage limited to Uc max. and oscillating frequency limited to 00 Hz max. b Slight increase in drop-out time (. to. times the normal time). Mounting Uc Reference Weight kg Clip-on mounting on all ratings and all a.c. coils. a V LA FRCE V LA FRCF V LA FRCP 0.00 V LA FRCV 0.00 Suppressor block bracket LA D Varistors (peak limiting) b Protection provided by limiting the transient voltage to Uc max. b Maximum reduction of transient voltage peaks. Clip-on mounting on all ratings and all coils. a or c V LA FVE V LA FVF V LA FVP 0.00 V LA FVV LA Fp0 LA Fp0 Diodes b No overvoltage or oscillating frequencies. b Increase in drop-out time ( to times the normal time). b Polarised component. Clip-on mounting on all ratings and all d.c. coils. c V LA FDE V LA FDF V LA FDP V LA FDV 0.00 Bidirectional peak limiting diodes (transil) b Protection provided by limiting the transient voltage to between and. times Uc max. b Maximum reduction of transient voltage peaks. Clip-on mounting on all ratings and all coils. a or c V LA FTE V LA FTF V LA FTP 0.00 V LA FTV 0.00 Connection accessories For use on -pole contactors Set of links Weight Set reference kg Links for parallel connection of poles (in pairs) LC F LA FF LC F0, F LA FG0 0.0 LC F, F, F0, F00 LA FH0.000 LC F00 LA FK0.0 LC F0 LA FL Links for star connection of poles LC F LA FF0 0.0 LC F0, F LA FG LC F, F, F0, F00 LA FH0 0.0 LC F00 LA FK0 0.0 LC F0, F00 LA FL0 0.0 DZ FA Control circuit voltage take-off from power terminals For use with contactors Mounted on bolt size Sold in lots of Unit reference Weight kg LC F M 0 DZ FA 0.00 LC F0, F M 0 DZ GA 0.00 LC F F00 M0 0 DZ HA 0.00 LC F0, F00 M 0 DZ JA Dimensions : pages / and / /
22 References (continued) TeSys contactors TeSys Fcontactors Accessories 0 Right-angled connectors For contactors or thermal overload relays For use with With connector plates Set of connectors Contactors Thermal overload Set reference Weight relays () Width Type kg LC F LR Fp, LR F mm Rear LA FF LA Fp LA Fp LC F0, F LC F, F, F0, F00 LC F00 LC F0, F00 LR Fp, Fp, LR F, F Side LA FF 0.0 Large LA FF0 0.0 surface area 0 mm Rear LA FG 0.00 Side LA FG 0.0 Large LA FG surface area LR Fp,LR F mm Rear LA FJ 0.0 LR Fp, Fp, LR F, F Side LA FJ 0.0 Large LA FJ0 0.0 surface area 0 mm Rear LA FK 0.0 Side LA FK 0.0 Large LA FK surface area LR Fp,LR F 0 mm Rear LA FL.0 Side LA FL.0 DB0 DF LA FL0 LA F0 Large surface area LA FL0.0 For use with With connector Set of connectors Contactors plates Set reference Weight Width Type kg LC F0 0 mm Rear LA F0.0 LC F00, F00, F00 0 mm Rear LA F00.0 Connection accessories For reversing contactors or "star-delta" contactors combined with a thermal overload relay For use with Contactors LC F LC F0 and F LC F LC F and F LC F0 and F00 Thermal overload relays () LR Fp, Fp LR Fp, Fp LR F, F Width of connector plates Set of busbars Set reference Weight kg mm LA F0 0.0 LR Fp, Fp 0 mm LA F0 0.0 LR Fp, LR F LR Fp, LR F LR Fp, Fp LR F, F LR Fp, Fp LR F, F mm LA F0 0.0 mm LA F0 0.0 mm LA F0 0.0 mm LA F0 0.0 LC F00 LR Fp,LR F mm LA F0 0.0 LC F00 LR Fp, Fp LR Fp LR F, F, F 0 mm LA F0 0.0 LC F0, F00 LR Fp, LR F 0 mm LA F LA F00 () For protection relays class 0, replace the p with a and for class 0, replace the p with a. 0 Dimensions : pages / and / /
23 References (continued) TeSys contactors TeSys F contactors Accessories 0 Insulated terminal blocks For use on Connection -pole contactors LC F, F0, F x 0 mm or x mm Tightening tool mm hexagonal socket key Set of blocks Weight Set reference kg LA F0 0.0 LA F0 Power terminal protection shrouds For use on, and -pole contactors Number of shrouds per set Set reference Weight kg LC F LA F0 0.0 LC F0, F LA F LC F, F, F0, F00 and F00 F00 and F00 LA F0 0.0 LC F0, F0 and F00 LA F0 0.0 LC F LA F LA F0 LC F0 and F LA F LC F, F, F0, F00, F00 LA F LC F0 LA F /
24 References TeSys contactors TeSys F contactors Spare parts 0 LA FG LA F000 LA F000 Sets of contacts Per pole: fixed contacts, moving contact, deflectors, back-plate, clamping screws and washers. For contactor Type Replacement for Reference Weight kg -pole LC F00 poles LA F000.0 LC F00 poles LA F000.0 LC F0 poles LA F00.00 LC F0S0 poles LA F00S0.00 -pole LC F. F0 poles LA FF 0.0 LC F. F poles LA FG 0.0 LC F poles LA FH 0.0 LC F0. F00 poles LA F LC F00 poles LA F000.0 LC F0 poles LA F00.00 LC F0 pole LA F00 ().00 poles LA F00.00 LC F00 poles LA F LC F0S0 poles LA F00S0.00 -pole LC F0. F poles LA FF 0.0 LC F. F poles LA FG 0. LC F poles LA FH 0.0 LC F0. F00 poles LA F LC F00 poles LA F LC F0 poles LA F00.0 LC F0 pole LA F00 ().00 poles LA F00.00 LC F0S0 poles LA F00S0.00 Arc chambers For contactor Type Replacement Reference for Weight kg -pole LC F00 poles LA F LC F00 poles LA F000.0 LC F0 poles LA F00.00 LC F0S0 poles LA F pole LC F poles LA F0 0.0 LC F0 poles LA F LC F poles LA F0 0.0 LC F poles LA F0 0.0 LC F poles LA F0 0.0 LC F0 poles LA F00.00 LC F00 poles LA F LC F00 poles LA F000.0 LC F0 poles LA F00.0 LC F0 pole LA F00 ().00 LC F00 poles LA F000.0 LC F0S0 poles LA F00.0 LC F0 poles LA F00.0 LC F00 poles LA F000 ().0 LC F00 poles LA F000 ().0 LC F00 poles LA F000 ().0 -pole LC F poles LA F0 0.0 LC F0 poles LA F LC F poles LA F0 0.0 LC F poles LA F0.000 LC F poles LA F0.0 LC F0 poles LA F00.0 LC F00 poles LA F000 ().0 LC F00 poles LA F000 ().00 LC F0 poles LA F00 ().00 LC F0 pole LA F00 ().00 LC F0S0 poles LA F00.00 () Comprising identical items per pole. () Comprising three -pole arc chambers. () Comprising two -pole arc chambers. () Comprising single-pole arc chambers. 0 /
25 References TeSys contactors TeSys F contactors Accessories for assembly of reversing contactors and changeover contactor pairs using contactors, vertically mounted - for customer assembly 0 LA Fppp Closing of one of the contactors prevents closing of the other. Mechanical interlock kits Contactor type () Mechanical interlock () Top Middle Bottom Kit reference () Weight kg LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC F00, F00 or F00 (continued on page /) LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC F00, F00 or F00 LC F, F0, F or F0 LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC-F00, F00 or F00 LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F0 LC F, F0, F or F0 LC F00, F00 or F00 LC F, F0, F or F0 LA FFFF 0. LA FGFF 0. LA FGGF 0. LA FGGG 0. LA FHFF.0 LA FHGF. LA FHGG. LA FHHF. LA FHHG. LA FHHH. LA FJFF. LA FJGF. LA FJGG. LA FJHF. LA FJHG. LA FJHH. LA FJJF. LA FJJG. LA FJJH. LA FJJJ.0 LA FKFF. LA FKGF. LA FKGG. LA FKHF. LA FKHG. LA FKHH. LA FKJF. LA FKJG. LA FKJH. LA FKJJ. LA FKKF. () To order the contactors, see pages / and /. For auxiliary contact blocks LAD N0 used for electrical locking, see page /. For accessories, see pages / to /. () Minimum distances between contactors, see page /. () The kit contains the lever arms, the x Ø mm rods and all parts required for assembly. Selection : pages / to / /
26 References (continued) TeSys contactors TeSys F contactors Accessories for assembly of reversing contactors and changeover contactor pairs using contactors, vertically mounted - for customer assembly LA Fppp Mechanical interlock kits (continued) Contactor type () Mechanical interlock () Top Middle Bottom Kit reference () Weight kg LC F00, F00 or F00 (continued) LC F0, F00, F0 or F0 LC F00, F00 or F00 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC-F00, F00 or F00 LC F0, F00, F0 or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC-F00, F00 or F00 LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC-F00, F00 or F00 LC F, F0, F or F0 LC F, F, F or F LC F, F0, F or F0 LC F00, F00 or F00 LC F00, F00 or F00 LC F0, F00, F0, or F0 LA FKKG. LA FKKH. LA FKKJ. LA FKKK. LA FLFF. LA FLGF. LA FLGG. LA FLHF.0 LA FLHG.0 LA FLHH. LA FLJF. LA FLJG. LA FLJH. LA FLJJ.0 LA FKKF. LA FKKG. LA FKKH. LA FKKJ. LA FKKK. LA FLLF.0 LA FLLG. LA FLLH.0 LA FLLJ. LA FLLK. LA FLLL.0 () To order the contactors, see pages / and /. For auxiliary contact blocks LAD N0 used for electrical locking, see page /. For accessories, see pages / to /. () Minimum distances between contactors. This is the distance, in mm, between the centres of two adjacent contactors (between the top and middle contactors or between the middle and bottom contactors). Contactor Bottom or top Middle LC F or F0 LC F or F LC F or F0 LC F00 LC F00 LC F0 or F00 LC F or F LC F or F LC F or F LC F LC F LC F0 or F () The kit contains the lever arms, the x Ø mm rods and all parts required for assembly. 0 Selection : pages / to / /
27 References TeSys contactors TeSys F contactors a.c. 0/0 Hz supply coils 0 LX FFppp LX FGppp References Maximum ambient air temperature: C. Above this, use an LX F coil, see page /. Operating cycles/hour (q y C): y 00. Control circuit voltage Uc - 0 Hz Uc - 0 Hz Average resistance at 0 C ± 0 % Inductance of closed circuit Voltage code Reference Weight V V W H kg For contactors LC F and LC F B LX FF D LX FF E LX FF E LX FF F LX FF G LX FF F LX FF FE LX FF0 0.0 /.. G LX FF /0.. L LX FF M LX FF U LX FF /.. M LX FF P LX FF U LX FF Q LX FF R LX FF /0. 0. Q LX FF V LX FF N LX FF S LX FF Y LX FF /0. Y LX FF LX FF LX FF Average consumption at 0 C: - inrush 0Hz: 0VA; 0Hz: 0 VA, sealed 0Hz: VA; 0 Hz: VA, cos j Heat dissipation: W. Operating time at Uc: closing ms, opening ms. For contactors LC F and LC F B LX FG LX FG E LX FG E LX FG F LX FG0 0.0 /0. 0. G LX FG F LX FG FE LX FG0 0.0 /. 0. G LX FG /0.. L LX FG M LX FG U LX FG /.. M LX FG P LX FG U LX FG Q LX FG R LX FG /0.. Q LX FG V LX FG N LX FG S LX FG Y LX FG /0. Y LX FG LX FG LX FG Average consumption at 0 C: - inrush 0 Hz: 0 VA; 0 Hz: 0 VA, sealed 0 Hz: VA; 0 Hz: VA, cos j Heat dissipation: W. Operating time at Uc: closing 0 ms, opening ms. /0
28 References TeSys contactors TeSys F contactors a.c. 0 to 00 Hz supply coils LX FHppp LX FJppp References Low sealed consumption. Operate on networks with harmonic numbers y. Operating cycles/hour (q y C): y 00. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactors LC F and LC F () B LX FH () E LX FH () F LX FH () FE LX FH /. () G LX FH /0. () L LX FH () M LX FH () P LX FH () U LX FH0 0.0 () W LX FH () Q LX FH () V LX FH0 0.0 () N LX-FH () R LX FH /00 () S LX FH /0 0 () X LX FH () LX FH Average consumption at 0 C for 0 or 0 Hz and cos j 0.: - inrush: VA, - sealed: 0 VA. Heat dissipation: W. Operating time at Uc: closing 0 ms, opening 00 0 ms. For contactor LC F E LX FJ /0. 0. F LX FJ FE LX FJ /. 0. G LX FJ /0 0. L LX FJ M LX FJ P LX FJ U LX FJ0.000 / 00. W LX FJ Q LX FJ V LX FJ N LX FJ R LX FJ S LX FJ /00 0. X LX FJ LX FJ Average consumption at 0 C for 0 or 0 Hz and cos j 0.: - inrush: VA, - sealed: VA. Heat dissipation: W. Operating time at Uc: closing 0 ms, opening () Please consult your Regional Sales Office. 0 /
29 References (continued) TeSys contactors TeSys F contactors a.c. 0 to 00 Hz supply coils LX FKppp LX FLppp References (continued) Low sealed consumption. Operate on networks with harmonic numbers y. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactor LC F E LX FK0.0 0/0. 0. F LX FK FE LX FK0.0 0/.. G LX FK.0 00/0. L LX FK M LX FK P LX FK U LX FK0.0 /. 0. W LX FK Q LX FK V LX FK N LX FK R LX FK S LX FK00.0 0/00 0. X LX FK LX FK000.0 Average consumption at 0 C for 0 or 0 Hz, cos j 0.: - inrush: 00 0 VA, - sealed: 0 VA. Operating cycles/hour (q y C): y 00. Heat dissipation: W. Operating time at Uc: closing 0 ms, opening 00 0 ms. For contactor LC F0 and LC F E LX FL0 ().00 0/0.. F LX FL FE LX FL G LX FL.00 00/ L LX FL M LX FL P LX FL U LX FL0.00 / 00. W LX FL Q LX FL V LX FL N LX FL R LX FL S LX FL /00 0. X LX FL LX FL000 ().00 () Incompatible with LCF0. Average consumption at 0 C for 0 or 0 Hz, cos j 0.: - inrush: 00 0 VA, - sealed: 0 VA. Operating cycles/hour (q y C): 00. Heat dissipation: 0 W. Operating time at Uc: closing 0 0 ms, opening ms. 0 /
30 References (continued) TeSys contactors TeSys F contactors a.c. 0 to 00 Hz supply coils References (continued) Low sealed consumption. Operate on networks with harmonic numbers y. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactor LC F0 0/0. () 0 () 0. F LX FX0 ().000. () 0 () 0. FE LX FX0 ().000. () 0 () 0. G LX FX () /0. () 0 () 0. L LX FX00 () () 0 () 0. M LX FX0 () () 0 () 0. P LX FX0 () () 0 () 0. U LX FX0 ().000 /. () 0 (). W LX FX0 () () 0 (). Q LX FX0 () () 0 (). V LX FX0 ().000 /0. () 0 (). N LX FX () () 0 (). R LX FX () () 0 (). S LX FX00 ().000 Average consumption at 0 C for 0 or 0 Hz, cos j 0.: - inrush: VA, sealed: VA. Operating cycles/hour (q y C): 00. Heat dissipation: x W. Operating time at Uc: closing 0 0 ms, opening 0 0 ms. For contactor LC F00 Control circuit voltage Uc V Voltage code Rectifier Reference () Coil Reference Weight 0/ FE DR TEU LX FFW.0 0/0 P DR TEU LX FMW.0 0/0 V DR TES LX FQW.0 Operating cycles/hour (q y C): 00. Average consumption at 0 C for 0 or 0 Hz, cos j 0.: - inrush: 00 VA, sealed: VA Operating time at Uc: closing 0 0 ms, opening 0 0 ms. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference kg Weight V W W H kg For contactors LC F00, LC F00 and LC F F LX FK0 () G LX FK00 () M LX FK0 () P LX FK0 () U LX FK () W LX FK0 ().0 0. Q LX FK00 () V LX FK00 ().0.. N LX FK0 () R LX FK0 () S LX FK0 ().0 Average consumption at 0 C for 0 or 0 Hz, cos j 0.: - inrush: VA, sealed: VA. Operating cycles/hour (q y C): 00. Heat dissipation: x W. Operating time at Uc: closing 0 ms, opening 00 0 ms. () Reference of set of identical coils, to be connected in series. () Value for the coils in series. () Rectifier to be ordered separately: 0.00 kg. () Order coils and connect them in series. 0 /
31 References TeSys contactors TeSys F contactors a.c. 0 to 00 Hz supply coils for specific applications () LX FFppp LX FGppp References Low sealed consumption. High tolerance to inrush voltage drops. Immune to micro-breaks (mains supply or contact chain). Operate on networks with harmonic numbers y. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactors LC F and LC F E LX FF F LX FF FE LX FF /. G LX FF L LX FF M LX FF P LX FF U LX FF Q LX FF V LX FF N LX FF R LX FF S LX FF Average consumption at 0 C: inrush: 0 VA, sealed:.. VA. Heat dissipation:.. W. Operating cycles/hour (q y C): < 00. Operating time at Uc: closing ms, opening 0 ms. For contactors LC F and LC F E LX FG F LX FG FE LX FG / 0. G LX FG L LX FG M LX FG P LX FG U LX FG Q LX FG V LX FG N LX FG R LX FG S LX FG Average consumption at 0 C: inrush: 0 0 VA, sealed:. 0. VA. Heat dissipation:. W. Operating cycles/hour (q y C): < 00. Operating time at Uc: closing ms, opening 0 ms. For contactors LC F and LC F0. () LX FH /. () LX FH /. () LX FH 0.0 0/0. () LX FH () LX FH / 0 () LX FH () LX FH Average consumption at 0 C: inrush: 0 0 VA, sealed: 0 VA. Heat dissipation:. 0. W. Operating cycles/hour (q y C): < 00. Operating time at Uc: closing ms, opening ms. () Application examples: hoisting (inching, high operating rates), Main-Standby (unstable mains supplies). These coils are particularly suited for use at higher operating temperatures (mounting in non-ventilated compartments, enclosures, etc.). () Please consult your Regional Sales Office. 0 Schemes: page / /
32 References (continued) TeSys contactors TeSys F contactors a.c. 0 to 00 Hz supply coils for specific applications References (continued) Coils with short operating times (at Uc): - N/O: 0 ms, - N/C: 0 ms (a side); 0 ms (c side). Coils with high operating rates (q y 0 C): - 00 operating cycles/hour, - 00 for LC F0. 0 LX FJppp LX FKppp LX FLppp Coils with low inrush consumption. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Rectifier Reference () Coil Reference Weight V W W H kg For contactor LC F DR TFV LX FJ DR TEU LX FJ DR TEU LX FJ 0.0 0/0. DR TEU LX FJ 0.0 0/ 0 DR TES LX FJ DR TES LX FJ DR TES LX FJ 0.0 Average consumption: - inrush: 00 VA, - sealed: VA Heat dissipation:.. W. For contactor LC F DR TFV LX FK DR TEU LX FK DR TEU LX FK.00 0/0. 0 DR TEU LX FK.00 0/ 0 DR TES LX FK DR TES LX FK DR TES LX FK.00 Average consumption: - inrush: 0 VA, - sealed: VA Heat dissipation:. W. For contactor LC F DR TFV LX FL DR TEU LX FL DR TEU LX FL.0 0. DR TEU LX FL0.0 0/0.. DR TEU LX FL.0 0/00 0. DR TES LX FL.0 /0 0 0 DR TES LX FL DR TES LX FL.0 Average consumption: - inrush: 0 VA, - sealed: VA Heat dissipation:.. W. () Rectifier to be ordered separately: 0.00 kg. 0 Schemes: page / /
33 References TeSys contactors TeSys F contactors d.c. supply coils LX FFppp LX FHppp References Low sealed consumption. Operating cycles/hour (q y C): y 00. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactors LC F and LC F0. BD LX FF ED LX FF FD LX FF GD LX FF 0.0 0/ MD LX FF UD LX FF / RD LX FF0 0.0 Average consumption: - inrush: W, - sealed:.. W. Operating time at Uc: closing 0 0 ms, opening 0 0 ms. For contactors LC F and LC F 0.. BD LX FG ED LX FG FD LX FG GD LX FG 0.0 0/ MD LX FG UD LX FG / RD LX FG0 0.0 Average consumption: - inrush: 0 W, - sealed:..0 W. Operating time at Uc: closing 0 0 ms, opening 0 0 ms. For contactors LC F and LC F0 0.. BD LX FH ED LX FH FD LX FH GD LX FH 0.0 0/ MD LX FH UD LX FH / RD LX FH0 0.0 Average consumption: - inrush: 0 W, - sealed:.. W. Operating time at Uc: closing 0 0 ms, opening 0 ms. For contactor LC F00. ED LX FJ FD LX FJ GD LX FJ MD LX FJ UD LX FJ RD LX FJ0 0.0 Average consumption: - inrush: 0 0 W, - sealed:. W. Operating time at Uc: closing 0 0 ms, opening 0 ms. 0 Schemes: page / /
34 References (continued) TeSys contactors TeSys F contactors d.c. supply coils LX FKppp References (continued) Low sealed consumption. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of closed circuit Voltage code Reference Weight V W W H kg For contactor LC F00. ED LX FK FD LX FK GD LX FK MD LX FK UD LX FK RD LX FK0.00 Average consumption: - inrush: 0 0 W, sealed:. W. - Operating cycles/hour (q y C): 00. Operating time at Uc: closing 0 0 ms, opening 0 ms. For contactor LC F0 and LC F0. 0. ED LX FL FD LX FL GD LX FL () MD LX FL UD LX FL RD LX FL0 ().0 () Incompatible with LC F0. Average consumption: - inrush: 0 0 W, sealed:.. W. - Operating cycles/hour (q y C): 00. Operating time at Uc: closing 0 0 ms, opening 0 0. For contactor LC F0 0. () 0 () 0. FD LX FX0 ().000. () 0 () 0. GD LX FX () () 00 () MD LX FX0 () () 0 (). UD LX FX0 () () 0 (). RD LX FX0 ().000 Average consumption: - inrush: 0 0 W, sealed: W. - Operating cycles/hour (q y C): 00. Operating time at Uc: closing 0 0 ms, opening 00 0 ms. For contactor LC F00 0/0 FW LX FFW.0 0/0 MW LX FMW.0 0/00 QW LX FQW.0 Heat dissipation: W. Operating time at Uc: closing 0 0 ms, opening 0 0 ms. For contactors LC F00, LC F00 and LC F00 0. FD LX FK0 ().00. GD LX FK0 () MD LX FK0 () UD LX FK () RD LX FK0 ().00 Average consumption: - inrush: W, sealed: 0 W. - Operating cycles/hour (q y C): 00. Operating time at Uc: closing 0 0 ms, opening 0 ms. () Reference of set of identical coils, to be connected in series. () Value for the coils in series. () Order coils and connect them in series. 0 Schemes: page / /
35 References TeSys contactors TeSys F contactors d.c. supply coils for specific applications References Coils with short operating times (at Uc) : - N/O: 0 ms, - N/C: 0 ms. Coils with high operating rates (q y 0 C): - 00 operating cycles/hour, - 00 for LC F0. LX FJppp LX FKppp LX FLppp Coils with low inrush consumption. Control circuit voltage Uc Average resistance at 0 C ± 0 % Inrush Sealed Inductance of Qty Reference Reference Weight Resistor () Coil closed required circuit V W W H kg For contactor LC F DR SC00 LX FJ DR SC00 LX FJ DR SC00 LX FJ DR SC00 LX FJ 0.0 0/0 00 DR SC00 LX FJ 0.0 Average consumption: - inrush: 0 W, - sealed: W. For contactor LC F DR SC00 LX FK DR SC00 LX FK.00.. DR SC00 LX FK DR SC000 LX FK.00 0/0 00 DR SC00 LX FK.00 Average consumption: - inrush: 0 W. - sealed: W. For contactor LC F DR SC00 LX FL DR SC00 LX FL DR SC00 LX FL DR SC000 LX FL.0 0/ DR SC00 LX FL.0 Average consumption: - inrush: W. - sealed: W. () Resistor to be ordered separately, weight of resistor: 0.00 kg. 0 Schemes: page / /
TeSys contactors 5. TeSys F contactors Auxiliary contact blocks. Maximum number of blocks per contactor Clip-on mounting
s Auxiliary contact blocks ravailable nd half 00. Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts Maximum number of blocks per contactor Clipon mounting
More informationTeSys contactors. TeSys D contactors. 690 V on a and c
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationTeSys contactors. Rated operational. current in AC V up to. kw kw kw kw kw kw kw A kg
Referenes TeSys ontators TeSys D ontators for motor ontrol up to kw at 00 V, in ategory AC- For onnetion y srew lamp terminals and lugs D0pp Dpp -pole ontators Standard power ratings of -phase motors 0-0
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationMasterpact. Installation recommendations
90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationInstallation Contactors ISU-xxx ISM-xxx
Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More information6 - TeSys protection components: relays and controllers
Contents - : relays and controllers Selection guide............................................. page / Motor and machine protection................................. page / TeSys K, thermal overload relays
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More information90 MCB range Modular circuit breakers for circuit protection
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationZelio Relay - Solid State Relays
Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationTeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P
Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationModular contactors for installation into distribution
Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More information5730A High Performance Multifunction Calibrator. Extended specifications
730A High Performance Multifunction Calibrator Extended specifications General Specifications Warm-Up Time... Twice the time since last warmed up, to a maximum of 30 minutes. System Installation... Rack
More informationDouble Thyristor Module For Phase Control MT A2
Electrically isolated base plate Industrial standard package Simplified mechanical design, rapid assembly Pressure contact PROTON-ELECTROTEX RUSSIA Double Thyristor Module For Phase Control MT3-595-18-A2
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationMiniatur Circuite Breakers (MCB)
Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationEXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 2008 (12041002) (X-Paper) 09:00 12:00 EXEMPLAR This question paper consists of 7 pages. EXEMPLAR -2- NC(V) TIME: 3 HOURS
More informationSemiconductor (AC) fuses
PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate
More informationSelecting the current rating for equipment
Selecting the current rating for equipment 1. Rated current: the maximum continuous load current. Short-time withstand current: thermal withstand current term term is given for 1s or 3s short circuit current
More information7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S
Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact
More informationmicroswitches Low force
0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E
The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and
More informationTeSys contactors. TeSys F contactors. b1 =
Dimensions TeSys onttors TeSys F onttors LC F to F0 () S S X X L Q P P Q fm Z Y J J X (mm) Minimum eletril lerne ording to operting voltge nd reking pity. LC 00 00 V 00 000 V F, F0 0 F 0 F, F 0 F0 0 ()
More informationDigital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW
Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:
More informationMINIATURE MICROSWITCHES - PREMIUM
0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationStandard Rectifier Module
Standard ectifier Module = 2x16 M I = 31 A FA F = 1.3 Phase leg Part number MDD312-16N1 Backside: isolated 2 1 3 Features / Advantages: Applications: Package: Y1 Package with B ceramic Improved temperature
More informationTeSys DF IEC-Type Fuseholders
TeSys DF IEC-Type 9080CT080 08 Contents... Page Characteristics......3 Accessories... Dimensions...5 Wirg diagrams...5 Fuses...6 7 Characteristics TeSys DF IEC-Type Fuseholder type DF8 DF0 DF DF DFCC Environment
More informationTYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B
FEATURES Non inductive High pulse loading capability. APPLICATIONS Application for overload and high voltage surge hazard circuits. DESCRIPTION A carbon film is deposited on a high grade ceramic body.
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationSUBMINIATURE MICROSWITCHES - PREMIUM
0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More informationIntroduction to AC Circuits (Capacitors and Inductors)
Introduction to AC Circuits (Capacitors and Inductors) Amin Electronics and Electrical Communications Engineering Department (EECE) Cairo University elc.n102.eng@gmail.com http://scholar.cu.edu.eg/refky/
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed
More informationMINIATURE MICROSWITCHES - PREMIUM
0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationCapacitive Sensors. Contents
Contents Capacitive sensors detect the change in capacitance caused by the approach of an object. Their advantage lies in the ability to detect virtually any material, from metals to oils. 4.2 Definitions,
More informationFEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components
FEATURES Excellent anti-surge characteristics Stable characteristics to moisture resistance even in high resistance range. Good replacement for ceramic plate resistors. APPLICATIONS Telecommunication Industrial
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION RATED PRIMARY OLTAGE () This is the supply assigned to the transformer by the manufacturer. RATED SECONDARY OLTAGE () This is the secondary output assigned to the transformer when
More informationModel M3484 Industrial Line Noise Filter Module Customer Reference Manual
Model M3484 Industrial Line Noise Filter Module Customer Reference Manual Web: www.bonitron.com Tel: 615-244-2825 Email: info@bonitron.com Bonitron, Inc. Bonitron, Inc. Nashville, TN An industry leader
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationWT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.
More informationELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT
Chapter 31: ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT 1 A charged capacitor and an inductor are connected in series At time t = 0 the current is zero, but the capacitor is charged If T is the
More informationStandard Rectifier Module
Standard ectifier Module = 16 M I = 56 A FA F =.98 Single Diode Part number MDO5-16N1 Backside: isolated 2 3 Features / Advantages: Applications: Package: Y1 Planar passivated chips ery low leakage current
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationMulti-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits
200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE
More informationSemiconductor (AC) fuses
BS88 Fuses x1, 17x9, X17x9, 6 VAC EXTREMELY HIGH BREAKING CAPACITY FUSES: PROTECTION OF POWER SEMICONDUCTORS AS PER IEC STANDARD 6069.1 AND 6 V VOLTAGE RATING COMPLYING WITH IEC GR CLASS (RATINGS FROM
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationInterference suppression film capacitors MKP 336 1
MKP RADIAL POTTED TYPE PITCH /15/22.5/27.5 mm l b h lt P d t CBA196 Fig.1 Simplified outlines. FEATURES to 27.5 mm lead pitch Supplied loose in box and taped on reel Consists of a low-inductive wound cell
More informationUNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Level
UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Level *3242847993* PHYSICS 9702/43 Paper 4 A2 Structured Questions October/November 2012 2 hours Candidates
More informationNM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- /
P0. Type designation N M / Type of Npole for P breaker* pplication: lank: for power distribution; : for motor protection elease type and accessory code (please refer to table on page 9) Number of poles
More informationSeries CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch
PART NUMBER CCT-58S DESCRIPTION Commercial Normally Open Multi-throw, DC-18 GHz The CCT-58S/CT-58S is an internally terminated, broadband, multi-throw, electromechanical coaxial switch designed to switch
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More information