Modular contactors for installation into distribution
|
|
- Logan Hardy
- 5 years ago
- Views:
Transcription
1 Modular contactors for installation into distribution boards Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres, sport centers, production halls, warehouses etc. They are used for remote switching and automatic control of electric devices and equipment, such as: lightning all types of pumps air-conditioning electric heating single-phase and three-phase motors They excel in silent operation, long mechanical life time and high quality. The contactors are designed for mounting on mm mounting rail in accordance with the EN 0 standard and they can be leaded by means of lead covers. The auxiliary contact block is available for signalization and ventilation module is available for preventing exceeded heating when contactors are used side-by-side. All contactors have degree of protection IP0. Besides the basic AC controlled types R0, R, R0 and R, types with increased silent operation RD0, RD, RD0 and RD are available. Due to DC magnet and rectifier enable DC and AC voltage control. Surge arrestor is built in for over voltage protection. s R0-R, RD0-R, R-R and RD-R are upgraded versions of basic types of modular contactors. Besides basic functions they enable manual control with a handle. Description of the handle positions: A: the contactor functions as an installation contactor without manual control O: permanently OFF I: manual shifting the handle from position A to I causes the contactor to close; when control voltage is applied, the handle is automatically set to position A. s RD0-R and RD-R are provided with a varistor for over voltage protection and a rectifier, which enables control with AC and DC voltage. Contactors with manual control enable: switching depending on tariff (selection of the most convenient tariff) switching when control voltage is not applied Technical specifications according to: EN09--; EN09--; VDE 00, IEC 9--; IEC 9--
2 Modular contactors for installation into distribution boards - type R -pole, module (, mm), 0 A (AC, 00 V) R 0-0 0V R 0-0 V 00 0 R 0-0 V R 0- V 00 0 R V R 0-0 V pole, module (, mm), A (AC, 00 V) R -0-V 000 A 0 R -0-0V 0000 A 0 -pole, module (, mm), A (AC, 00 V) R -0-V 000 A 0 R -0 0V 000 A 0 R - V 000 A 0 R - 0V 000 A R 0 R -0 V 000 A R 0 R -0 0V 000 A R R 0 -pole, modules ( mm), A (AC, 00 V) R -0 0 V R -0 V 00 0 R - 0 V R - V 00 0 R - 0 V R - V 00 0 R - 0 V R - V 00 0 R -0 0 V R -0 V 00 0 is used where ambient temperature is higher than 0 C. Piece width is / module (, mm) Max contactors can be side by side - use of distance piece P0 is highly recommended. Technical data on page 0
3 Modular contactors for installation into distribution boards - type R -pole, modules (, mm), 0 A (AC, 00 V) R V R 0-0 V 00 0 R 0-0 V R 0- V 00 0 R 0-0 V R 0- V 00 0 R V R 0-0 V 00 0 pole, modules (,mm), A(AC, 00 V) R -0 0 V R -0 V 00 0 R - 0 V R - V 00 0 R - 0 V R - V 00 0 R -0 0 V R -0 V 00 0 Auxiliary contactor block for contactors R, R0, R (max. piece) RH 000 Leaded cover For use with P 000 R 0 P R 0, R 0 For use with P0 000 R0-R 0 is used where ambient temperature is higher than 0 C. Piece width is / module (, mm) Max contactors can be side by side - use of distance piece is highly recommended. Technical data on page 0
4 Modular contactors for installation into distribution boards - type RD, R...R, RD...R -pole, module (, mm), 0 A (AC, 0 V) RD 0-0-0V AC/DC RD 0-0-V AC/DC 0000 RD 0-0-0V AC/DC 0000 R RD 0-0-V AC/DC 0000 R RD 0-0-0V AC/DC 0000 RD 0-0-V AC/DC 0000 RD 0--0V AC/DC 0000 RD 0--V AC/DC 0000 RD 0-0-0V AC/DC 0000 A A R R -pole, module (, mm), 0 A (AC, 0 V) R R RD 0-0-V AC/DC Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. -pole, modules ( mm), A (AC, 00 V) RD -0-0V AC/DC 0000 RD -0-V AC/DC 000 RD --0V AC/DC 000 R RD --V AC/DC 000 R RD --0V AC/DC 000 R RD --V AC/DC 000 R R RD -0-0V AC/DC 000 R R R R R R RD -0-V AC/DC 000 Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. R pole, modules (, mm), 0 A (AC, 00 V) RD 0-0-0V AC/DC 000 RD 0-0-V AC/DC 0009 RD 0--0V AC/DC 0000 R RD 0--V AC/DC 000 R RD 0--0V AC/DC 000 R RD 0--V AC/DC 000 R R RD 0-0-0V AC/DC 000 R R RD 0-0-V AC/DC 000 R R R Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. R R pole, modules (,mm), A(AC, 00 V) RD -0-0V AC/DC 000 RD -0-V AC/DC 000 RD --0V AC/DC 000 R RD --V AC/DC 0009 R RD --0V AC/DC 0000 R RD --V AC/DC 000 Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. Technical data on page 0 R R 9
5 Modular contactors for installation into distribution boards - type RD, R...R, RD...R -pole, ON - OFF - AUTO, module (, mm), 0 A (AC, 00 V) R 0-0-R-0V AC 000 R 0-0-R-V AC 000 RD 0-0-R-0V AC/DC 000 RD 0-0-R-V AC/DC 000 R 0-0-R-0V AC 000 R 0-0-R-V AC 000 RD 0-0-R-0V AC/DC RD 0-0-R-V AC/DC pole, ON - OFF - AUTO, module (, mm), 0 A (AC, 00 V) R 0-0-R-0V AC 0000 R 0-0-R-V AC 000 RD 0-0-R-0V AC/DC 000 RD 0-0-R-V AC/DC 000 R 0--R-0V AC 000 R 0--R-V AC 000 RD 0--R-0V AC/DC 000 RD 0--R-V AC/DC 000 R 0-0-R-0V AC 000 R 0-0-R-V AC 0009 RD 0-0-R-0V AC/DC 0000 RD 0-0-R-V AC/DC 000 Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. R R R R R R 0 0 -pole, ON - OFF - AUTO, modules ( mm), A (AC, 00 V) R -0-R-0V AC 000 R -0-R-V AC 000 RD -0-R-0V AC/DC 000 RD -0-R-V AC/DC 000 R --R-0V AC 000 R --R-V AC 000 RD --R-0V AC/DC 000 RD --R-V AC/DC 0009 R --R-0V AC 0000 R --R-V AC 000 RD --R-0V AC/DC 000 RD --R-V AC/DC 000 R -0-R-0V AC 000 R -0-R-V AC 000 RD -0-R-0V AC/DC 000 RD -0-R-V AC/DC 000 Take care of dissipated heat by: 0 C max. modules side by side 0 - C max. modules side by side. R R R R R R R R R R R R 0 0 Technical data on page 0
6 Modular contactors for installation into distribution boards - type RD, R...R, RD...R Auxiliary contactor block for contactors RD, R R, RD R RN RN RN * The auxiliary switch should not be applied in combination with RD0 and RD0-R. 0 Sealing cover For use with SC0 000 RD 0, R0...R SC 000 RD, R...R SC0/ 000 RD 0, RD 0 For use with IKV 000 RD, R...R Technical data on page 0
Installation Contactors ISU-xxx ISM-xxx
Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More information90 MCB range Modular circuit breakers for circuit protection
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationDATA SHEET. BYD63 Ripple blocking diode DISCRETE SEMICONDUCTORS Jun 10
DISCRETE SEMICONDUCTORS DATA SHEET book, halfpage M3D9 Supersedes data of November 995 File under Discrete Semiconductors, SC 996 Jun FEATURES Glass passivated High maximum operating temperature Low leakage
More informationMiniatur Circuite Breakers (MCB)
Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationSemiconductor (AC) fuses
PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate
More informationMiniature Circuit Breaker
Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload
More informationNR2 Thermal Overload Relay. 4. Technical Data. 1. General. 2. Type Designation. 3. Features. Item Series No. I/In Operating time Tp Test condition
s elays C US N Thermal Overload elay. General. Certificates: CB,CE, UL, PCT, CC, VDE;. Electric ratings: C 0/0z, V, 0.~;.3 Tripping class: 0;. Mounting version: a. Plug-in: vailable for N-.,, 3, 93, 0;
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationTeSys contactors. TeSys D contactors. 690 V on a and c
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationZNR Transient/Surge Absorbers (Type E)
ZNR Transient/Surge Absorbers Type : E The ZNR Type E is capable of handling larger surge energy than Type D in applications to protect electronic equipment or semiconductor devices from switching and
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationInstruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution
Instruction 0001-22-2--00 Vacuum Circuit Breaker Operator Module Type 3AH 4.16kV to 38kV Power Transmission & Distribution Hazardous voltages and high-speed moving parts. Will cause death, serious injury
More informationCNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The CNY64/ CNY65/ CNY66 consist of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead plastic package. The
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationPOWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R. Power Quality For The Digital Age
Power Quality For The Digital Age POWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R Introduction One method to measure the efficiency of the electrical
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationLEDlight 30 W Universal dimmable series
LEDlight 30 W Universal dimmable series L05031 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications. System reliability
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationDistributing Tomorrow s Technologies For Today s Designs Toll-Free:
2W, Ultra-High Isolation DIP, Single & DC/DC s Key Features Low Cost 6 Isolation MTBF > 6, Hours Short Circuit Protection Input, and 24 Output,, 1, {, { and {1 Regulated Outputs Low Isolation Capacitance
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationMeasurement method for the proficiency testing program
APLAC T088 Appendix Measurement method for the proficiency testing program Introductions This measurement method is prepared for use by the APLAC Proficiency Testing Program Photometric measurement of
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationUNISONIC TECHNOLOGIES CO., LTD
UNISONIC TECHNOLOGIES CO., LTD BIPOLAR LATCH TYPE HALL EFFECT FOR HIGH-TEMPERATURE OPERATION DESCRIPTION 1 SIP-3 The UTC SK1816 is a semiconductor integrated circuit utilizing the Hall effect. It designed
More informationELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz
ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet
More informationRemote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.
Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.
More informationSION Lateral 3AE6 Vacuum Circuit Breaker with Lateral Operating Mechanism
Catalog HG.07 Edition 03/ 07 SION Lateral 3AE Vacuum Circuit Breaker with Lateral Operating Mechanism Medium-Voltage Equipment siemens.com/sion R-HG-3.psd Catalog HG.07 03 / 07 SION 3AE Vacuum Circuit
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationMultilayer Ceramic Chip Capacitors
HIGH VOLTAGE SERIES JARO high voltage series Multilayer Ceramic Capacitors are constructed by depositing alternative layers of ceramic dielectric materials and internal metallic electrodes, by using advanced
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationPHOS 15 LED PROJECTOR
PHOS 15 LED PROJECTOR SPECIFICATIONS Item:.. PHOS 15 Body:.... Aluminium Available Colours:... White / Black / Silver Weight:.... 1.9 kg On / Off Switch:..... Not Available Environmental Conditions:.....
More information16 Input AC Block I/O Module
6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More informationHIGH POWER THICK FILM CHIP FIXED RESISTOR
HIGH POWER THICK FI CHIP FIXED RESISTOR 2W High power up to 2W Current detecting resistors for power supply, motor circuits ROHS Compliant with RoHS directive etc Halogen free requirement Switching Power
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationHAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS
MICRONAS INTERMETALL HAL1...HAL, HAL Hall Effect Sensor ICs Edition May, 1997 1--1DS MICRONAS HAL1...HAL HAL Hall Effect Sensor IC in CMOS technology Common Features: switching offset compensation at khz
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationMODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH
MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box
More informationQTi DALI-T/E 2X18 42/ DIM
QTi DALI-T/E 2X18 42/220 240 DIM QUICKTRONIC INTELLIGENT DALI DIM CFL ECG dimmable DALI for CFL Suitable for emergency light installations Product benefits Easy change of defect ECG thanks to available
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationMAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features
W, Miniature SIP, Single & Dual Output DC/DC s Key Features Efficiency up to % 000 Isolation MTBF >,000,000 Hours Low Cost Input,, and Output 3.3,,9,,,{,{9,{ and { Temperature Performance -0] to +] UL
More informationLEDlight 20 W Universal dimmable series
LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.
More informationZelio Relay - Solid State Relays
Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage
More informationDATA SHEET. BAV100 to BAV103 General purpose diodes DISCRETE SEMICONDUCTORS Sep 17. Product specification Supersedes data of April 1996
DISCRETE SEMICONDUCTORS DATA SHEET 1/3 page (Datasheet) M3D054 Supersedes data of April 1996 1996 Sep 17 FEATURES Small hermetically sealed glass SMD package Switching speed: max. 50 ns General application
More informationCALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05
Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LDSR 0.3-TP/SP1 I P R N = 300 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More informationDATA SHEET. BYD11 series Controlled avalanche rectifiers DISCRETE SEMICONDUCTORS Sep 26
DISCRETE SEMICONDUCTORS DATA SHEET book, halfpage M3D Supersedes data of April 996 File under Discrete Semiconductors, SC 996 Sep 6 FEATURES Glass passivated High maximum operating temperature Low leakage
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationEXISTING PANEL "22C" CIR.# TYPE DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN % (E) 400A MLO
EXISTING PANEL "22C" DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN 3 4 100% (E) 400A MLO COND BREAKER LOAD LOAD BREAKER PHASE. SIZE AMP P (KVA) (KVA)
More informationWater terminal control solutions
Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the
More information400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL
400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. July 2013 REV. 015 2013 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix AP Harmonic
More informationDATA SHEET. BYD31 series Fast soft-recovery controlled avalanche rectifiers DISCRETE SEMICONDUCTORS Sep 18
DISCRETE SEMICONDUCTORS DATA SHEET andbook, halfpage M3D Supersedes data of 996 Jun 5 File under Discrete Semiconductors, SC 996 Sep 8 FEATURES Glass passivated High maximum operating temperature Low leakage
More informationC310T-SC 3.6 mm x 10 mm Time-delay, axial lead ceramic tube fuses
Pb HALOGEN HF FREE Applications Primary circuit protection: Power supplies LED and general lighting Consumer electronics Desktop, laptop and notebook Test equipment Agency information curus Recognition
More informationRedline Unibis : the solution Circuit protection
2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board
More informationTechnical Concepts - Fault Analysis Methods
RATIO X/R Technical Concepts - Fault Analysis Methods Technical Concepts - Fault Analysis Methods (Continued) "What is the difference between a traditional fault calculation and an ANSI-based fault calculation"
More informationCHIP RESISTOR. Chip Resistors Selection Guide. General Purpose Chip Resistor. Zero Ohm Jumper Resistor. Chip Resistor Array MAX WORKING VOLTAGE
Chip Resistors Selection Guide General Purpose Chip Resistor SIZE/ mm POWER RATING MAX WORKING VOLTAGE TOLERANCE RESISTANCE RANGE 0402 1.00*0.50 0603 1.60*0.80 1/10W 0. 0805 2.00*1.25 1/8W 1 0. 1206 3.10*1.60
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More informationPeriodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018
Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions Version and date Change detail Section 1.3 July 2018 Modified questions/answers
More informationSuperconducting Fault Current Limiters
Superconducting Fault Current Limiters First Friday Club 1 st April 2011 Gerhard Novak UK Technical Manager Joachim Bock Managing Director, Nexans Superconductors 1 Smart Grid Solutions 2 Fault current
More informationProducts Overview 3. MD Series 4. Packing & Dimension 5. Products Overview 8. Explanation of Part Number 9. D Series (5D, 7D, 10D, 14D, 20D) 10
Advanced Material On TECHnology - AMOTECH Disk Varistor/ SMD Molded Varistor >> CONTENTS SMD Molded Varistor Products Overview 3 MD Series 4 Packing & Dimension 5 Disk Varistor Products Overview 8 Explanation
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationUNISONIC TECHNOLOGIES CO., LTD
UNISONIC TECHNOLOGIES CO., LTD BIPOLAR LATCH TYPE HALL EFFECT FOR HIGH-TEMPERATURE OPERATION DESCRIPTION 1 SIP-3 The UTC SK1816 is a semiconductor integrated circuit utilizing the Hall effect. It designed
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationDATA SHEET. BYD77 series Ultra fast low-loss controlled avalanche rectifiers DISCRETE SEMICONDUCTORS May 24
DISCRETE SEMICONDUCTORS DATA SHEET book, halfpage M3D Supersedes data of December 99 File under Discrete Semiconductors, SC 996 May 4 FEATURES Glass passivated High maximum operating temperature Low leakage
More informationPushbutton Units and Indicator Lights
Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded
More informationCat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More information