WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
|
|
- Brendan Clarke
- 5 years ago
- Views:
Transcription
1 WT L- Laser Photoelectric proximity switches, background suppression -- DC mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression max. 0 0 Adjustments possible WT L-F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optic axis, receiver Mounting hole l. mm Sensitivity adjustment C V Connection type WT L-F 0 Laser class Accessories page Cable receptacles 9 Mounting brackets 0 -pin, M L+ M SENSICK CATALOGUE
2 WT L- Technical data WT L- F mm, adjustable Light source ), light type Light spot diameter LED laser, red light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP, Q and Q Output current I A max. 00 ma Response time ) 00 µs Max. switching frequency ) 000/s Connection type Plug VDE protection class ) Laser class ) (IEC /VDE 0) Circuit protection 9) A, B, C Enclosure rating IP V Ambient temperature T A Operation 0 C...+ C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 0,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal flight time with ohmic load ) With light/dark ratio : ) Reference voltage 0 V DC ) Low power. Eyes normally by averting reaction and eyelid closing reflex. 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression %/90% Order information Type WT L-F 0 Part no (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 %/90% 0 (mm) SENSICK CATALOGUE
3 WT - Photoelectric proximity switches, background suppression, red light -- DC Photoelectric proximity switches Red light mm Adjustable background suppression Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -F 0 WT -P 0 WT -F WT -N 0 WT -F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch t0 t t t+t t0 t t t+t > 0.sec < 0.sec Switch-selectable time delay 0. 0 s s t 0 Without time delay t 0 Without time delay t OFF-delay from trailing t OFF-delay from trailing t ON-delay from leading t ON-delay from leading t + t OFF- and ON-delay t + t OFF- and ON-delay C V WT -F 0 WT -F WT -P 0 WT -F 0 WT -N 0 Accessories page Cable receptacles 9 Mounting brackets 0 -pin, M -pin, M -pin -pin SENSICK CATALOGUE
4 WT - Technical data WT - F 0 F P 0 F0 N mm, adjustable Light source ), light type Light spot diameter LED, red light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma Response time ) ms Max. switching frequency ) 0/s Selectable delay ranges s/ s Test input TE, sender OFF PNP: Test input to 0 V NPN: Test input to V S Plug VDE protection class ) Circuit protection ) V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage 0 V DC ) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression (mm) %/90% %/90% Order information Type WT -F 0 WT -F WT -P 0 WT -F 0 WT -N 0 Part no on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 (mm) SENSICK CATALOGUE
5 WT - Photoelectric proximity switches, background suppression, red light -- UC mm Photoelectric proximity switches Dimensional drawing.. Red light Adjustable background suppression Selectable time delay max. 0 0 t Adjustments possible Standard direction of the material being scanned WT -S WT -R 0 LED signal strength indicator WT -S 0 Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch X Light-switching t 0 t 0 t Dark-switching t t Switch-selectable time delay t +t t + t 0. 0 s dark light t 0 Without time delay 0. 0 s t OFF-delay from trailing t ON-delay from leading t + t OFF- and ON-delay C V WT -S WT -R 0 WT -S 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin -pin blk blk blu blu red red brn brn ora ora SENSICK CATALOGUE
6 WT - Technical data WT - S R 0 S mm, adjustable Light source ), light type Light spot diameter LED, red light Approx. mm at 00 mm Supply voltage V S...0 VUC (+0%, 0%) Current consumption < VA Switching outputs SPDT, isolated ) Max. switching voltage 0 V AC / 0 V DC Max. switching current A / 0 V AC or V DC Max. switching capacity AC 000 V A / DC 00 W Resonse time < ms Max. switching frequency ) 0/s Delay range s Cable ), m Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Provide suitable spark suppression for inductive and capacitive loads ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V AC ) A = V S connections reverse-polarity C = Interference pulse suppression (mm) %/90% %/90% Order information Type WT -S WT -R 0 WT -S 0 Part no on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 (mm) SENSICK CATALOGUE 9
7 WT - Photoelectric proximity switches, background suppression, infrared light -- DC mm Photoelectric proximity switches Infrared light Adjustable background suppression Front screen heating, optional Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -F WT -P 0 WT -F 0 WT -P 0 WT -F 0 WT -N 0 WT -F WT -N 0 WT -F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch t0 t t t+t t0 t t t+t > 0.sec < 0.sec Switch-selectable time delay 0. 0 s s t 0 Without time delay t 0 Without time delay t OFF-delay from trailing t OFF-delay from trailing t ON-delay from leading t ON-delay from leading t + t OFF- and ON-delay t + t OFF- and ON-delay C V WT -F WT -F 0 WT -P 0 WT -N 0 WT -F 0 WT -F WT -P 0 WT -N 0 WT -F 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin, M -pin, M -pin -pin L+ M 0 SENSICK CATALOGUE
8 WT - Technical data WT - F F 0 N 0 F F 0 P 0 P 0 N 0 F mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma ma, front screen heating Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma Response time ) ms Max. switching frequency ) 0/s Selectable delay ranges s/ s Test input TE, sender OFF PNP : Test input to 0 V NPN : Test input to V S Cable ), m Plug VDE protection class ) Circuit protection 9) V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Front screen heating Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 %/90% %/90% 0 (mm) Order information Type WT -F WT -F 0 WT -N 0 WT -F WT -F 0 WT -P 0 WT -P 0 WT -N 0 WT -F 0 Part no SENSICK CATALOGUE
9 WT - Photoelectric proximity switches, background suppression, infrared light -- UC mm Photoelectric proximity switches Infrared light Adjustable background suppression Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -S WT -R 0 WT -S 0 t 0 t 0 t t t t t +t t + t dark light 0. 0 s Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch X Light-switching Dark-switching Switch-selectable time delay 0. 0 s t 0 Without time delay t OFF-delay from trailing t ON-delay from leading t + t OFF- and ON-delay C V WT -S WT -R 0 WT -S 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin -pin blk blk blu red brn ora blu red brn ora SENSICK CATALOGUE
10 WT - Technical data WT - S R 0 S mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at 00 mm Supply voltage V S...0 VUC (+0%, 0%) Current consumption < VA Switching outputs SPDT, isolated ) Max. switching voltage 0 V AC / DC 0 V Max. switching current A / 0 V AC or V DC Max. switching capacity AC 000 V A / DC 00 W Response time < ms Max. switching frequency ) 0/s Delay range s Cable ), m Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Provide suitable spark suppression for inductive and capacitive loads ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V AC ) A = V S connections reverse-polarity C = Interference pulse suppression (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 %/90% 0 %/90% 0 (mm) Order information Type WT -S WT -R 0 WT -S 0 Part no SENSICK CATALOGUE
11 WT - ASI Photoelectric proximity switches, background suppression, red/infrared light -- DC mm Dimensional drawing mm Photoelectric proximity switches Red/infrared light Adjustable background suppression Front screen heating, optional (only for infrared type) Integrated ASI chip max Adjustments possible WT -Z 0 WT -Z 0 WT -Z 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment C V Connection type WT -Z 0 WT -Z 0 WT -Z 0 Accessories page Cable receptacles 9 Mounting brackets 0 ASI -pin, M SENSICK CATALOGUE
12 WT - Technical data WT - Z 0 Z0 Z mm, adjustable mm, adjustable Light source ), light type Light spot diameter LED, red light LED, infrared light Approx. mm at 00 mm Approx. mm at 00 mm Supply voltage V S... VDC ) Ripple ) V SS Current consumption ) 0 ma 0 ma, front screen heating Response time ) ms Max. switching frequency ) 0/s Connection type Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Front screen heating Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage 0 V DC ) A = V S connections reverse-polarity C = Interference pulse suppression 9) Black = % remission Grey = % remission White = 90 % remission Assignment of data bits (Host level) Assignment of parameter bits (Host level) Switching state 0 No reflection Input D 0 * Reflection Alarm 0 Active Input D Inactive NC 0 Input D Test function 0 Sender ON Output D * * Default setting = Sender OFF NC 0 Parameter P 0 * Light-/dark-switching 0 Dark-switching Parameter P * Light-switching NC 0 Parameter P * NC 0 Parameter P * %/90% %/90% %/90% (mm) %/90% on black 9) red light on grey 9) red light on white 9) red light on black 9) on grey 9) infrared light infrared light on white 9) infrared light 0 (mm) % of scanning distance Order information Type WT -Z 0 WT -Z 0 WT -Z 0 Part no SENSICK CATALOGUE
W 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More informationW 34: Sensor technology that does justice to demanding requirements
KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationD i s t a n ce Sensor DS 60
D i s t a n ce Sensor DS 0 T E C H N I C A L D E S C R I P T I O N Distance Sensor DS 0 Application Field The DS 0 distance sensors operate according to the principle of time of flight measurement. The
More informationOnline data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS
Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80
More informationProduct description. Developing lighter, more compact and. photoelectric sensor offers completely. ligent features: the sensors feature
W2S-2 Miniature photoelectric sensors Product description Developing lighter, more compact and photoelectric sensor offers completely ligent features: the sensors feature housing size. Whether it is used
More informationVL 18-3/4 Photoelectric reflex switch, polarising filter, red light -- DC. M18x1 M18x1 27.6
L -/ Photoelectric reflex switch, polarisig filter, red light -- DC Scaig rage 0.0....7 m Photoelectric reflex switch With polarizig filter, which esures reliable detectio of objects with shiy surfaces
More informationE6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders
Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationcompact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog
with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationDimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial
Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationPressure Display Controller
MODEL DW Display Controller Low The Model DW pressure controller accurately monitors and controls very low pressures. It combines in one enclosure a low pressure transducer, a digital display and two alarms
More informationPHOTOTRANSISTOR OPTOCOUPLERS
DESCRIPTION The CNY7 series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. FEATURES CNY7-/2/3 are also available in white package by specifying -M suffix (eg. CNY7-2-M) UL recognized
More informationPHOTODARLINGTON OPTOCOUPLERS
DESCRIPTION The CNX48U, HBX, and TIL3 have a gallium arsenide infrared emitter optically coupled to a silicon planar photodarlington. CNX48U HB HB2 HB255 HB3 TIL3 FEATURES High sensitivity to low input
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More informationDisplay counter electromechanical
Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E
The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and
More information4-PIN PHOTOTRANSISTOR OPTOCOUPLERS
PACKAGE HAA84 SCHEMATIC 4 COLLECTOR 4 2 3 EMITTER DESCRIPTION The HAA84 Series consists of two gallium arsenide infrared emitting diodes, connected in inverse parallel, driving a single silicon phototransistor
More informationPLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (10-30VDC)
PLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (-0VDC) Diameter Q8 Q8 Shielded non-shielded Switching Distance, Sn: mm Housing Material With Without 1.5 mm 1.5 mm Picture Dimensions (unit: mm) 8 7. 8 8 0.5.5
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication
Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More information4-PIN PHOTOTRANSISTOR OPTOCOUPLERS
PACKAGE HAA84 SCHEMATIC 4 COLLECTOR 4 2 3 EMITTER DESCRIPTION The HAA84 Series consists of two gallium arsenide infrared emitting diodes, connected in inverse parallel, driving a single silicon phototransistor
More informationAC INPUT/PHOTOTRANSISTOR OPTOCOUPLERS
HAA HAA3 HAA2 HAA4 DESCRIPTION The HAAX series consists of two gallium-arsenide infrared emitting diodes connected in inverse parallel driving a single silicon phototransistor output. FEATURES Bi-polar
More informationPHOTOTRANSISTOR OPTOCOUPLERS
DESCRIPTION The CNY7 series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. FEATURES CNY7-/2/3 are also available in white package by specifying -M suffix (eg. CNY7-2-M) UL recognized
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationEmergency lighting units EM Inverter
T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationHIGH SPEED TRANSISTOR OPTOCOUPLERS
SINGLECHANNEL: PACKAGE SCHEMATIC N/C V CC + V CC V F + V F 7 V B _ 7 V 0 _ V O _ V 0 V F N/C 4 5 GND + 4 5 GND,,, Pin 7 is not connected in Part Number / DESCRIPTION The /, / and / optocouplers consist
More informationDIN Timers TD. Options and ordering codes. Specification
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationPHOTO SCR OPTOCOUPLERS
PACKAGE SCHEMATIC 6 6 ANODE 6 GATE CATHODE 2 5 ANODE N/C 3 4 CATHODE 6 DESCRIPTION The HC series consists of a gallium-arsenide infrared emitting diode optically coupled with a light activated silicon
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationPHOTOVOLTAIC SOLID-STATE RELAY OPTOCOUPLERS
PACKAGE SCHEMATIC ANODE 6 DRAIN 6 CATHODE 2 5 6 N/C 3 4 DRAIN DESCRIPTION The HSR32 and HSR42 devices consist of a AlGaAs infrared emitting diode optically coupled to a power MOSFET detector which is driven
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationPhoto-electric sensors1
References Three-wire DC, solid-state output Teach mode - + Sensing distance (Sn) m Depending on Function Output Connection Reference Weight NO/NC Prograable PNP Pre-cabled XUDAPSML 0.00 M XUDAPSMM 0.00
More informationMOC8111 MOC8112 MOC8113
PACKAGE SCHEMATIC ANODE 6 N/C 6 6 CATHODE 2 5 COLLECTOR N/C 3 4 EMITTER 6 DESCRIPTION The MOC8X series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. The base of the transistor
More informationMOC8101, MOC8102, MOC8103, MOC8104, MOC8105 Optocoupler, Phototransistor Output, no Base Connection
MOC80, MOC80, MOC803, MOC80, MOC80 Optocoupler, Phototransistor Output, no Base Connection i79009- DESCRIPTION The MOC80, MOC80, MOC803, MOC80, MOC80 family optocoupler consisting of a gallium arsenide
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationPotentiometer e.t.c. 1/240 with attach to our switching device 2011
Potentiometer e.t.c. /20 { = 0. kohm, with centre tap 2 x 0. kohm 2 =.0 kohm, with centre tap 2 x.0 kohm = resistance value linear and part number ^= = 2.0 kohm, with centre tap 2 x 2.0 kohm =.0 kohm,
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationH11AV1-M H11AV1A-M H11AV2-M H11AV2A-M
PACKAGE OUTLINE SCHEMATIC 6 6 HAVS-M, HAV2S-M 6 HAV-M, HAV2-M 2 3 NC PIN. ANODE 2. CATHODE 3. NO CONNECTION 4. EMITTER 5. COLLECTOR 6. BASE 5 4 6 HAVA-M, HAV2A-M DESCRIPTION The general purpose optocouplers
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationEMI Suppression PCRC 420 film capacitors (RC unit)
MKP RADIAL POTTED CAPACITORS Pitch 15.0/17.5 mm P = 15.0 / 17.5mm QUICK REFERENCE DATA Capacitance value Capacitance tolerance Resistance value Resistance tolerance Rated (AC) voltage 50 to 60 Hz Climatic
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power
More informationPhototransistor. Industry Standard Single Channel 6 Pin DIP Optocoupler
Phototransistor Industry Standard Single Channel 6 Pin DIP Optocoupler DEVICE TYPES Part No. CTR % Min. Part No. CTR % Min. 4N25 2 MCT2 2 4N26 2 MCT2E 2 4N27 MCT27 5 4N28 MCT27 45 9 4N35 MCT272 75 5 4N36
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationPAA-ANALYZERS PRINCIPLE OF OPERATION
PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationMODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)
Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationBay Linear. 1.0Amp Low Dropout Voltage Regulator B1117
Bay Linear Inspire the Linear Power 1.Amp Low Dropout oltage Regulator B1117 Adjustable & Fix (.4olt Dropout) Description The Bay Linear B1117 is a three terminal positive NPN regulator offered as adjustable
More informationMKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits
MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no
More informationDigital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW
Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationRail Guide Modular Linear Actuators DSM
Roller Guide Modular Linear Actuators DLM, DLVM Rail Guide Modular Linear Actuators DSM nookindustries.com toll-free (800) 32-7800 25 DLM 20, 60, 200 Linear Motor Drive Specifications Function: This unit
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationPHOTOTRANSISTOR OPTOCOUPLERS
MCT MCTE MCT0 MCT7 MCT00 MCT0 MCT0 WHITE PACKAGE (-M SUFFIX) BLACK PACKAGE (NO -M SUFFIX) DESCRIPTION The MCTXXX series optoisolators consist of a gallium arsenide infrared emitting diode driving a silicon
More informationInterference suppression film capacitors MKP 336 1
MKP RADIAL POTTED TYPE PITCH /15/22.5/27.5 mm l b h lt P d t CBA196 Fig.1 Simplified outlines. FEATURES to 27.5 mm lead pitch Supplied loose in box and taped on reel Consists of a low-inductive wound cell
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer GO-SME series I P N = 10 20 A Ref: GO 10-SME, GO 20-SME For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
More informationGENERAL PURPOSE 6-PIN PHOTOTRANSISTOR OPTOCOUPLERS
4N37 HA HA2 HA3 HA4 HA5 WHITE PACKAGE (-M SUFFIX) SCHEMATIC 2 3 NC PIN. ANODE 2. CATHODE 3. NO CONNECTION 4. EMITTER 5. COLLECTOR. BASE 5 4 BLACK PACKAGE (NO -M SUFFIX) DESCRIPTION The general purpose
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer GO-SMS series I P N = 10... 30 A Ref: GO 10-SMS, GO 20-SMS, GO 30-SMS For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationOptocoupler, Phototransistor Output, no Base Connection
Optocoupler, Phototransistor Output, no Base Connection FEATURES A C NC 1 2 3 6 5 4 NC C E Isolation test voltage, 5 V RMS No base terminal connection for improved common mode interface immunity Long term
More information4N25 4N26 4N27 4N28. MAXIMUM RATINGS (TA = 25 C unless otherwise noted) SCHEMATIC. Order this document by 4N25/D STANDARD THRU HOLE
Order this document by N/D GlobalOptoisolator The N, N, N7 and N8 devices consist of a gallium arsenide infrared emitting diode optically coupled to a monolithic silicon phototransistor detector. Most
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationCTC 155 / 350 / 660 Dry-block calibrator
CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy
More informationMetallized Polyester PCMT 369 film capacitors
MKT RADIAL LACQUERED CAPACITORS (Dipped Type) Pitch 10.0/15.0/22.5/27.5 mm (reduced pitch ; 7.5mm) QUICK REFERENCE DATA Capacitance range (E12 series) Capacitance tolerance Rated voltage V Rdc Climatic
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer GO-SMS/SP3 series I P N = 10... 30 A Ref: GO 10-SMS/SP3, GO 20-SMS/SP3, GO 30-SMS/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More information5-V Low-Drop Fixed Voltage Regulator TLE 4269
5-V Low-Drop Fixed Voltage Regulator TLE 4269 Features Output voltage tolerance ±2 % 15 ma current capability Very low current consumption Early warning Reset output low down to V Q = 1 V Overtemperature
More informationPHOTODARLINGTON OPTOCOUPLERS (NO BASE CONNECTION)
MOC9 DESCRITION The MOC9 device has a gallium arsenide infrared emitting diode coupled to a silicon darlington phototransistor. ACKAGE DIMENSIONS IN ID. 0.270 (6.86) 0.240 (6.0) 6 FEATURES High current
More informationAC and Pulse PCMP 389 Metallized Polypropylene film capacitors
MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm (reduced pitch 7.5mm) QUICK REFERENCE DATA Capacitance range (E24 series) Capacitance tolerance Rated voltage (DC) Climatic category Temperature
More informationNo /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700
Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More information