1 WT L- Laser Photoelectric proximity switches, background suppression -- DC mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression max. 0 0 Adjustments possible WT L-F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optic axis, receiver Mounting hole l. mm Sensitivity adjustment C V Connection type WT L-F 0 Laser class Accessories page Cable receptacles 9 Mounting brackets 0 -pin, M L+ M SENSICK CATALOGUE

2 WT L- Technical data WT L- F mm, adjustable Light source ), light type Light spot diameter LED laser, red light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP, Q and Q Output current I A max. 00 ma Response time ) 00 µs Max. switching frequency ) 000/s Connection type Plug VDE protection class ) Laser class ) (IEC /VDE 0) Circuit protection 9) A, B, C Enclosure rating IP V Ambient temperature T A Operation 0 C...+ C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 0,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal flight time with ohmic load ) With light/dark ratio : ) Reference voltage 0 V DC ) Low power. Eyes normally by averting reaction and eyelid closing reflex. 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression %/90% Order information Type WT L-F 0 Part no (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 %/90% 0 (mm) SENSICK CATALOGUE

3 WT - Photoelectric proximity switches, background suppression, red light -- DC Photoelectric proximity switches Red light mm Adjustable background suppression Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -F 0 WT -P 0 WT -F WT -N 0 WT -F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch t0 t t t+t t0 t t t+t > 0.sec < 0.sec Switch-selectable time delay 0. 0 s s t 0 Without time delay t 0 Without time delay t OFF-delay from trailing t OFF-delay from trailing t ON-delay from leading t ON-delay from leading t + t OFF- and ON-delay t + t OFF- and ON-delay C V WT -F 0 WT -F WT -P 0 WT -F 0 WT -N 0 Accessories page Cable receptacles 9 Mounting brackets 0 -pin, M -pin, M -pin -pin SENSICK CATALOGUE

4 WT - Technical data WT - F 0 F P 0 F0 N mm, adjustable Light source ), light type Light spot diameter LED, red light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma Response time ) ms Max. switching frequency ) 0/s Selectable delay ranges s/ s Test input TE, sender OFF PNP: Test input to 0 V NPN: Test input to V S Plug VDE protection class ) Circuit protection ) V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage 0 V DC ) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression (mm) %/90% %/90% Order information Type WT -F 0 WT -F WT -P 0 WT -F 0 WT -N 0 Part no on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 (mm) SENSICK CATALOGUE

5 WT - Photoelectric proximity switches, background suppression, red light -- UC mm Photoelectric proximity switches Dimensional drawing.. Red light Adjustable background suppression Selectable time delay max. 0 0 t Adjustments possible Standard direction of the material being scanned WT -S WT -R 0 LED signal strength indicator WT -S 0 Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch X Light-switching t 0 t 0 t Dark-switching t t Switch-selectable time delay t +t t + t 0. 0 s dark light t 0 Without time delay 0. 0 s t OFF-delay from trailing t ON-delay from leading t + t OFF- and ON-delay C V WT -S WT -R 0 WT -S 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin -pin blk blk blu blu red red brn brn ora ora SENSICK CATALOGUE

6 WT - Technical data WT - S R 0 S mm, adjustable Light source ), light type Light spot diameter LED, red light Approx. mm at 00 mm Supply voltage V S...0 VUC (+0%, 0%) Current consumption < VA Switching outputs SPDT, isolated ) Max. switching voltage 0 V AC / 0 V DC Max. switching current A / 0 V AC or V DC Max. switching capacity AC 000 V A / DC 00 W Resonse time < ms Max. switching frequency ) 0/s Delay range s Cable ), m Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Provide suitable spark suppression for inductive and capacitive loads ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V AC ) A = V S connections reverse-polarity C = Interference pulse suppression (mm) %/90% %/90% Order information Type WT -S WT -R 0 WT -S 0 Part no on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 (mm) SENSICK CATALOGUE 9

7 WT - Photoelectric proximity switches, background suppression, infrared light -- DC mm Photoelectric proximity switches Infrared light Adjustable background suppression Front screen heating, optional Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -F WT -P 0 WT -F 0 WT -P 0 WT -F 0 WT -N 0 WT -F WT -N 0 WT -F 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch t0 t t t+t t0 t t t+t > 0.sec < 0.sec Switch-selectable time delay 0. 0 s s t 0 Without time delay t 0 Without time delay t OFF-delay from trailing t OFF-delay from trailing t ON-delay from leading t ON-delay from leading t + t OFF- and ON-delay t + t OFF- and ON-delay C V WT -F WT -F 0 WT -P 0 WT -N 0 WT -F 0 WT -F WT -P 0 WT -N 0 WT -F 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin, M -pin, M -pin -pin L+ M 0 SENSICK CATALOGUE

8 WT - Technical data WT - F F 0 N 0 F F 0 P 0 P 0 N 0 F mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at 00 mm Supply voltage V S VDC ) Ripple ) V SS Current consumption ) ma ma, front screen heating Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma Response time ) ms Max. switching frequency ) 0/s Selectable delay ranges s/ s Test input TE, sender OFF PNP : Test input to 0 V NPN : Test input to V S Cable ), m Plug VDE protection class ) Circuit protection 9) V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Front screen heating Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 0 %/90% %/90% 0 (mm) Order information Type WT -F WT -F 0 WT -N 0 WT -F WT -F 0 WT -P 0 WT -P 0 WT -N 0 WT -F 0 Part no SENSICK CATALOGUE

9 WT - Photoelectric proximity switches, background suppression, infrared light -- UC mm Photoelectric proximity switches Infrared light Adjustable background suppression Selectable time delay Dimensional drawing max. 0 0 Adjustments possible WT -S WT -R 0 WT -S 0 t 0 t 0 t t t t t +t t + t dark light 0. 0 s Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm Sensitivity adjustment Time control Time delay selector switch X Light-switching Dark-switching Switch-selectable time delay 0. 0 s t 0 Without time delay t OFF-delay from trailing t ON-delay from leading t + t OFF- and ON-delay C V WT -S WT -R 0 WT -S 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin -pin blk blk blu red brn ora blu red brn ora SENSICK CATALOGUE

10 WT - Technical data WT - S R 0 S mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at 00 mm Supply voltage V S...0 VUC (+0%, 0%) Current consumption < VA Switching outputs SPDT, isolated ) Max. switching voltage 0 V AC / DC 0 V Max. switching current A / 0 V AC or V DC Max. switching capacity AC 000 V A / DC 00 W Response time < ms Max. switching frequency ) 0/s Delay range s Cable ), m Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS ) Average service life 00,000 h at T A = + C ) Provide suitable spark suppression for inductive and capacitive loads ) With light/dark ratio : ) Do not bend below 0 C ) Reference voltage 0 V AC ) A = V S connections reverse-polarity C = Interference pulse suppression (mm) on black, % remission on grey, % remission on white, 90 % remission % of scanning distance 0 %/90% 0 %/90% 0 (mm) Order information Type WT -S WT -R 0 WT -S 0 Part no SENSICK CATALOGUE

11 WT - ASI Photoelectric proximity switches, background suppression, red/infrared light -- DC mm Dimensional drawing mm Photoelectric proximity switches Red/infrared light Adjustable background suppression Front screen heating, optional (only for infrared type) Integrated ASI chip max Adjustments possible WT -Z 0 WT -Z 0 WT -Z 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment C V Connection type WT -Z 0 WT -Z 0 WT -Z 0 Accessories page Cable receptacles 9 Mounting brackets 0 ASI -pin, M SENSICK CATALOGUE

12 WT - Technical data WT - Z 0 Z0 Z mm, adjustable mm, adjustable Light source ), light type Light spot diameter LED, red light LED, infrared light Approx. mm at 00 mm Approx. mm at 00 mm Supply voltage V S... VDC ) Ripple ) V SS Current consumption ) 0 ma 0 ma, front screen heating Response time ) ms Max. switching frequency ) 0/s Connection type Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Front screen heating Housing material ABS ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage 0 V DC ) A = V S connections reverse-polarity C = Interference pulse suppression 9) Black = % remission Grey = % remission White = 90 % remission Assignment of data bits (Host level) Assignment of parameter bits (Host level) Switching state 0 No reflection Input D 0 * Reflection Alarm 0 Active Input D Inactive NC 0 Input D Test function 0 Sender ON Output D * * Default setting = Sender OFF NC 0 Parameter P 0 * Light-/dark-switching 0 Dark-switching Parameter P * Light-switching NC 0 Parameter P * NC 0 Parameter P * %/90% %/90% %/90% (mm) %/90% on black 9) red light on grey 9) red light on white 9) red light on black 9) on grey 9) infrared light infrared light on white 9) infrared light 0 (mm) % of scanning distance Order information Type WT -Z 0 WT -Z 0 WT -Z 0 Part no SENSICK CATALOGUE

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

W250: Compact photoelectric switch series for a broad range of applications

W250: Compact photoelectric switch series for a broad range of applications W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications

More information

V 12: Miniature photoelectric switches in M 12 housings

V 12: Miniature photoelectric switches in M 12 housings Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They

More information

W 34: Sensor technology that does justice to demanding requirements

W 34: Sensor technology that does justice to demanding requirements KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to

More information

W 9 L: Laser photoelectric switches: small, light and reliable

W 9 L: Laser photoelectric switches: small, light and reliable W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The

More information

D i s t a n ce Sensor DS 60

D i s t a n ce Sensor DS 60 D i s t a n ce Sensor DS 0 T E C H N I C A L D E S C R I P T I O N Distance Sensor DS 0 Application Field The DS 0 distance sensors operate according to the principle of time of flight measurement. The

More information

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL80-S30 W80 WL80-S30 W80 A B C D E F Illustration may differ Ordering information Type Part no. WL80-S30 607484 Included in delivery: P0 (), BEF-W80 () Other models and accessories www.sick.com/w80

More information

Product description. Developing lighter, more compact and. photoelectric sensor offers completely. ligent features: the sensors feature

Product description. Developing lighter, more compact and. photoelectric sensor offers completely. ligent features: the sensors feature W2S-2 Miniature photoelectric sensors Product description Developing lighter, more compact and photoelectric sensor offers completely ligent features: the sensors feature housing size. Whether it is used

More information

VL 18-3/4 Photoelectric reflex switch, polarising filter, red light -- DC. M18x1 M18x1 27.6

VL 18-3/4 Photoelectric reflex switch, polarising filter, red light -- DC. M18x1 M18x1 27.6 L -/ Photoelectric reflex switch, polarisig filter, red light -- DC Scaig rage 0.0....7 m Photoelectric reflex switch With polarizig filter, which esures reliable detectio of objects with shiy surfaces

More information

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Multi-turn High-precision Encoder Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders Reset function for easy origin alignment when built-into equipment. Multi-turn

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Pressure Display Controller

Pressure Display Controller MODEL DW Display Controller Low The Model DW pressure controller accurately monitors and controls very low pressures. It combines in one enclosure a low pressure transducer, a digital display and two alarms

More information

PHOTOTRANSISTOR OPTOCOUPLERS

PHOTOTRANSISTOR OPTOCOUPLERS DESCRIPTION The CNY7 series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. FEATURES CNY7-/2/3 are also available in white package by specifying -M suffix (eg. CNY7-2-M) UL recognized

More information

PHOTODARLINGTON OPTOCOUPLERS

PHOTODARLINGTON OPTOCOUPLERS DESCRIPTION The CNX48U, HBX, and TIL3 have a gallium arsenide infrared emitter optically coupled to a silicon planar photodarlington. CNX48U HB HB2 HB255 HB3 TIL3 FEATURES High sensitivity to low input

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Display counter electromechanical

Display counter electromechanical Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical

More information

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

4-PIN PHOTOTRANSISTOR OPTOCOUPLERS

4-PIN PHOTOTRANSISTOR OPTOCOUPLERS PACKAGE HAA84 SCHEMATIC 4 COLLECTOR 4 2 3 EMITTER DESCRIPTION The HAA84 Series consists of two gallium arsenide infrared emitting diodes, connected in inverse parallel, driving a single silicon phototransistor

More information

PLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (10-30VDC)

PLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (10-30VDC) PLASTIC SQUARE INDUCTIVE PROXIMITY SENSOR (-0VDC) Diameter Q8 Q8 Shielded non-shielded Switching Distance, Sn: mm Housing Material With Without 1.5 mm 1.5 mm Picture Dimensions (unit: mm) 8 7. 8 8 0.5.5

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

RoHS. Versatile. X g. X 2 e

RoHS. Versatile. X g. X 2 e s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

4-PIN PHOTOTRANSISTOR OPTOCOUPLERS

4-PIN PHOTOTRANSISTOR OPTOCOUPLERS PACKAGE HAA84 SCHEMATIC 4 COLLECTOR 4 2 3 EMITTER DESCRIPTION The HAA84 Series consists of two gallium arsenide infrared emitting diodes, connected in inverse parallel, driving a single silicon phototransistor

More information

AC INPUT/PHOTOTRANSISTOR OPTOCOUPLERS

AC INPUT/PHOTOTRANSISTOR OPTOCOUPLERS HAA HAA3 HAA2 HAA4 DESCRIPTION The HAAX series consists of two gallium-arsenide infrared emitting diodes connected in inverse parallel driving a single silicon phototransistor output. FEATURES Bi-polar

More information

PHOTOTRANSISTOR OPTOCOUPLERS

PHOTOTRANSISTOR OPTOCOUPLERS DESCRIPTION The CNY7 series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. FEATURES CNY7-/2/3 are also available in white package by specifying -M suffix (eg. CNY7-2-M) UL recognized

More information

Impedance relay and protection assemblies

Impedance relay and protection assemblies RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T T TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM G, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

HIGH SPEED TRANSISTOR OPTOCOUPLERS

HIGH SPEED TRANSISTOR OPTOCOUPLERS SINGLECHANNEL: PACKAGE SCHEMATIC N/C V CC + V CC V F + V F 7 V B _ 7 V 0 _ V O _ V 0 V F N/C 4 5 GND + 4 5 GND,,, Pin 7 is not connected in Part Number / DESCRIPTION The /, / and / optocouplers consist

More information

DIN Timers TD. Options and ordering codes. Specification

DIN Timers TD. Options and ordering codes. Specification DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta versions Perfect to

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

PHOTO SCR OPTOCOUPLERS

PHOTO SCR OPTOCOUPLERS PACKAGE SCHEMATIC 6 6 ANODE 6 GATE CATHODE 2 5 ANODE N/C 3 4 CATHODE 6 DESCRIPTION The HC series consists of a gallium-arsenide infrared emitting diode optically coupled with a light activated silicon

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

PHOTOVOLTAIC SOLID-STATE RELAY OPTOCOUPLERS

PHOTOVOLTAIC SOLID-STATE RELAY OPTOCOUPLERS PACKAGE SCHEMATIC ANODE 6 DRAIN 6 CATHODE 2 5 6 N/C 3 4 DRAIN DESCRIPTION The HSR32 and HSR42 devices consist of a AlGaAs infrared emitting diode optically coupled to a power MOSFET detector which is driven

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Photo-electric sensors1

Photo-electric sensors1 References Three-wire DC, solid-state output Teach mode - + Sensing distance (Sn) m Depending on Function Output Connection Reference Weight NO/NC Prograable PNP Pre-cabled XUDAPSML 0.00 M XUDAPSMM 0.00

More information

MOC8111 MOC8112 MOC8113

MOC8111 MOC8112 MOC8113 PACKAGE SCHEMATIC ANODE 6 N/C 6 6 CATHODE 2 5 COLLECTOR N/C 3 4 EMITTER 6 DESCRIPTION The MOC8X series consists of a Gallium Arsenide IRED coupled with an NPN phototransistor. The base of the transistor

More information

MOC8101, MOC8102, MOC8103, MOC8104, MOC8105 Optocoupler, Phototransistor Output, no Base Connection

MOC8101, MOC8102, MOC8103, MOC8104, MOC8105  Optocoupler, Phototransistor Output, no Base Connection MOC80, MOC80, MOC803, MOC80, MOC80 Optocoupler, Phototransistor Output, no Base Connection i79009- DESCRIPTION The MOC80, MOC80, MOC803, MOC80, MOC80 family optocoupler consisting of a gallium arsenide

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Potentiometer e.t.c. 1/240 with attach to our switching device 2011

Potentiometer e.t.c. 1/240 with attach to our switching device 2011 Potentiometer e.t.c. /20 { = 0. kohm, with centre tap 2 x 0. kohm 2 =.0 kohm, with centre tap 2 x.0 kohm = resistance value linear and part number ^= = 2.0 kohm, with centre tap 2 x 2.0 kohm =.0 kohm,

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

H11AV1-M H11AV1A-M H11AV2-M H11AV2A-M

H11AV1-M H11AV1A-M H11AV2-M H11AV2A-M PACKAGE OUTLINE SCHEMATIC 6 6 HAVS-M, HAV2S-M 6 HAV-M, HAV2-M 2 3 NC PIN. ANODE 2. CATHODE 3. NO CONNECTION 4. EMITTER 5. COLLECTOR 6. BASE 5 4 6 HAVA-M, HAV2A-M DESCRIPTION The general purpose optocouplers

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

EMI Suppression PCRC 420 film capacitors (RC unit)

EMI Suppression PCRC 420 film capacitors (RC unit) MKP RADIAL POTTED CAPACITORS Pitch 15.0/17.5 mm P = 15.0 / 17.5mm QUICK REFERENCE DATA Capacitance value Capacitance tolerance Resistance value Resistance tolerance Rated (AC) voltage 50 to 60 Hz Climatic

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power

More information

Phototransistor. Industry Standard Single Channel 6 Pin DIP Optocoupler

Phototransistor. Industry Standard Single Channel 6 Pin DIP Optocoupler Phototransistor Industry Standard Single Channel 6 Pin DIP Optocoupler DEVICE TYPES Part No. CTR % Min. Part No. CTR % Min. 4N25 2 MCT2 2 4N26 2 MCT2E 2 4N27 MCT27 5 4N28 MCT27 45 9 4N35 MCT272 75 5 4N36

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Remote I/O R7KF Series I/O MODULE (-III) POWER INPUT DC power R: V DC (Operational voltage range: ±0 %; ripple 0 %p-p max.) 0 (8.7). (.) 7(.8) mm (inch) [] OPTIONS (multiple selections) Output data read

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

Bay Linear. 1.0Amp Low Dropout Voltage Regulator B1117

Bay Linear. 1.0Amp Low Dropout Voltage Regulator B1117 Bay Linear Inspire the Linear Power 1.Amp Low Dropout oltage Regulator B1117 Adjustable & Fix (.4olt Dropout) Description The Bay Linear B1117 is a three terminal positive NPN regulator offered as adjustable

More information

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits

MKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no

More information

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Digital Current Transducer HO-SW series I P N = 100... 250 A Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW Bitstream output from on onboard Sigma Delta modulator. For the electronic measurement of current:

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Rail Guide Modular Linear Actuators DSM

Rail Guide Modular Linear Actuators DSM Roller Guide Modular Linear Actuators DLM, DLVM Rail Guide Modular Linear Actuators DSM nookindustries.com toll-free (800) 32-7800 25 DLM 20, 60, 200 Linear Motor Drive Specifications Function: This unit

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

PHOTOTRANSISTOR OPTOCOUPLERS

PHOTOTRANSISTOR OPTOCOUPLERS MCT MCTE MCT0 MCT7 MCT00 MCT0 MCT0 WHITE PACKAGE (-M SUFFIX) BLACK PACKAGE (NO -M SUFFIX) DESCRIPTION The MCTXXX series optoisolators consist of a gallium arsenide infrared emitting diode driving a silicon

More information

Interference suppression film capacitors MKP 336 1

Interference suppression film capacitors MKP 336 1 MKP RADIAL POTTED TYPE PITCH /15/22.5/27.5 mm l b h lt P d t CBA196 Fig.1 Simplified outlines. FEATURES to 27.5 mm lead pitch Supplied loose in box and taped on reel Consists of a low-inductive wound cell

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer GO-SME series I P N = 10 20 A Ref: GO 10-SME, GO 20-SME For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

More information

GENERAL PURPOSE 6-PIN PHOTOTRANSISTOR OPTOCOUPLERS

GENERAL PURPOSE 6-PIN PHOTOTRANSISTOR OPTOCOUPLERS 4N37 HA HA2 HA3 HA4 HA5 WHITE PACKAGE (-M SUFFIX) SCHEMATIC 2 3 NC PIN. ANODE 2. CATHODE 3. NO CONNECTION 4. EMITTER 5. COLLECTOR. BASE 5 4 BLACK PACKAGE (NO -M SUFFIX) DESCRIPTION The general purpose

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer GO-SMS series I P N = 10... 30 A Ref: GO 10-SMS, GO 20-SMS, GO 30-SMS For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

Optocoupler, Phototransistor Output, no Base Connection

Optocoupler, Phototransistor Output, no Base Connection Optocoupler, Phototransistor Output, no Base Connection FEATURES A C NC 1 2 3 6 5 4 NC C E Isolation test voltage, 5 V RMS No base terminal connection for improved common mode interface immunity Long term

More information

4N25 4N26 4N27 4N28. MAXIMUM RATINGS (TA = 25 C unless otherwise noted) SCHEMATIC. Order this document by 4N25/D STANDARD THRU HOLE

4N25 4N26 4N27 4N28. MAXIMUM RATINGS (TA = 25 C unless otherwise noted) SCHEMATIC. Order this document by 4N25/D STANDARD THRU HOLE Order this document by N/D GlobalOptoisolator The N, N, N7 and N8 devices consist of a gallium arsenide infrared emitting diode optically coupled to a monolithic silicon phototransistor detector. Most

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

CTC 155 / 350 / 660 Dry-block calibrator

CTC 155 / 350 / 660 Dry-block calibrator CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy

More information

Metallized Polyester PCMT 369 film capacitors

Metallized Polyester PCMT 369 film capacitors MKT RADIAL LACQUERED CAPACITORS (Dipped Type) Pitch 10.0/15.0/22.5/27.5 mm (reduced pitch ; 7.5mm) QUICK REFERENCE DATA Capacitance range (E12 series) Capacitance tolerance Rated voltage V Rdc Climatic

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer GO-SMS/SP3 series I P N = 10... 30 A Ref: GO 10-SMS/SP3, GO 20-SMS/SP3, GO 30-SMS/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

5-V Low-Drop Fixed Voltage Regulator TLE 4269

5-V Low-Drop Fixed Voltage Regulator TLE 4269 5-V Low-Drop Fixed Voltage Regulator TLE 4269 Features Output voltage tolerance ±2 % 15 ma current capability Very low current consumption Early warning Reset output low down to V Q = 1 V Overtemperature

More information

PHOTODARLINGTON OPTOCOUPLERS (NO BASE CONNECTION)

PHOTODARLINGTON OPTOCOUPLERS (NO BASE CONNECTION) MOC9 DESCRITION The MOC9 device has a gallium arsenide infrared emitting diode coupled to a silicon darlington phototransistor. ACKAGE DIMENSIONS IN ID. 0.270 (6.86) 0.240 (6.0) 6 FEATURES High current

More information

AC and Pulse PCMP 389 Metallized Polypropylene film capacitors

AC and Pulse PCMP 389 Metallized Polypropylene film capacitors MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm (reduced pitch 7.5mm) QUICK REFERENCE DATA Capacitance range (E24 series) Capacitance tolerance Rated voltage (DC) Climatic category Temperature

More information

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700 Technical Manual Multistage-Temperature-/Differential Controller x700 Software Version 0078 o. 5303-0/06e 700 3700 5700 9700 3700 5700 9700 l Suitable as : Multistage Controller or Differential Controller

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information