1 with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working pressure min./max.. bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed air 0 mg/m³ - mg/m³ Protection class:with electrical connector See table below Duty cycle according to DIN VDE 0 standard 00 % Hysteresis adjustable Repeatability (% of full scale value) ± % DC operating voltage 4 V Voltage tolerance DC - % / +0% Switch output current Max. ma Materials: Housing Seal Silencers Aluminum, anodized Acrylonitrile Butadiene Rubber Polyethylene Technical Remarks Note: All data refers to an ambient pressure of 03 mbar and an ambient temperature of 0 C. The pressure dew point must be at least C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Type Nozzle Ø Power consumption Max. vacuum level at p.opt Max. suction capacity Air consumption at p.opt. Part No. Solenoid valve DC [mm] [W] [%] ECS-EC-0-NO ECS-EC--NO ECS-EC-0-NO ECS-EC-30-NO ECS-EC-0-NC ECS-EC--NC ECS-EC-0-NC ECS-EC-30-NC Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
2 Gripper and vacuum technology Vacuum generators with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Part No. Sound pressure level intake effect Sound pressure level intake effect Protection against overpressure (max.) Weight Note [db] [db] [bar] [kg] ; ; ) ; ; ) ; 4); 6) ; 4); 6) ; ; ) ; ; ) ; 4); 6) ; 4); 6) Nozzle material: Brass Nozzle material: Aluminum Protection class with electrical connector: IP 4) Protection class with electrical connector: IP6 ) Electr. connection: Plug; Industrial plug connector; -pin 6) Electr. connection: Plug; EN 730-3, form C p.opt. = optimum working pressure ECS-EC-...NO-C-S-VE 3(R) P (V) NO = ejector suction line open without current C = Solenoid valve for release pulse S = integrated non-return valve VE = electronic vacuum switch (P) ECS-EC-...NC-C-S-VE 3 (R) P (V) NC = ejector line closed without current C = Solenoid valve for release pulse S = integrated non-return valve VE = electronic vacuum switch (P) Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
3 with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog 3 Vacuum p depending on working pressure p p [%] Ø nozzle.0 mm Ø nozzle. mm optimum working pressure p [%] Ø nozzle.0 mm Ø nozzle 3.0 mm optimum working pressure Suction capacity s depending on working pressure p S Ø nozzle.0 mm Ø nozzle. mm optimum working pressure Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
4 4 Gripper and vacuum technology Vacuum generators with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog S Ø nozzle.0 mm Ø nozzle 3.0 mm optimum working pressure 007 Evacuation time te depending on vacuum p for l volume (with optimal operating pressure popt) t E[s/l] p [%] 0077 Ø nozzle.0 mm Ø nozzle. mm Ø nozzle.0 mm Ø nozzle 3.0 mm t E[s/l],8,6,4, 0,8 0,6 0,4 0, p [%] 0078 Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
5 with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Air consumption v depending on working pressure p V Ø nozzle.0 mm Ø nozzle. mm optimum working pressure V Ø nozzle.0 mm Ø nozzle 3.0 mm optimum working pressure Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
6 6 Gripper and vacuum technology Vacuum generators with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog ECS-EC-0/- L ) L G3 H0 G (V) H L6 L7 D L4 G4 G (P) L4 L B6 6) 7) L3 L B3 B B H3 H4 H H7 H8 H6 H3 H H9 H 9 ) 4) HS L3 0) 8) Vacuum ON/OFF solenoid valve; Release pulse solenoid valve; Vacuum switch; 4) Switching point setting for vacuum switch; ) LED switching point indicator for vacuum switch; 6) Silencer; 7) Filter 8) Hysteresis setting; 9) + UB (pin ; 0) analog output (pin ; switch output (pin 4); 0 V (pin Part No. B B B3 B6 D G G G3 G4 H H3 H G /8 G /8 M8x M G /8 G /8 M8x M G /8 G /8 M8x M G /8 G /8 M8x M Part No. H H6 H7 H8 H9 H0 H H H3 L L L Part No. L4 L L6 L7 L L3 L ,6 7, ,6 7, ,6 7, ,6 7, 7 Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
7 7 with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog ECS-EC-0/-30 L ) L8 L G3 B8 G H0 (V) H H3 B3 H4 B4 H H7 H8 6) L6 L4 D L7 L4 L B H6 H3 7) G G4 B6 (P) H H9 H H 4) HS 4) 9) Vacuum ON/OFF solenoid valve; Release pulse solenoid valve; Vacuum switch; 4) Switching point setting for vacuum switch; ) LED switching point indicator for vacuum switch; 6) Silencer; 7) Filter 8) Hysteresis setting; 9) + UB (pin ; 0) analog output (pin ; switch output (pin 4); 0 V (pin Part No. B B3 B4 B6 B8 D G G G3 G4 H H M8x G 3/8 G /4 M8x M M8x G 3/8 G /4 M8x M M8x G 3/8 G /4 M8x M M8x G 3/8 G /4 M8x M Part No. H3 H4 H H6 H7 H8 H9 H0 H H H3 L Part No. L L4 L L6 L7 L8 L Pneumatics catalog, online PDF, as of , AVENTICS S.à r.l., subject to change
Direct-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz
ELMO- Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz Selection diagram vacuum operation Selection diagram compressor operation The performance curves are valid for pumping air at 15 C at the inlet
More information/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2
/ way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationG 1/8 - G 3/8 G 1/2 - G 1 1/2. Poppet valves for compressed air 3/2
Poppet valves for compressed air Produced in a complete range of sizes from G 1/8 up to G 1 1/ these valves are particularly suitable for applications where high flow rates and high cycle rates are required.
More informationWT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430
WT L- Laser Photoelectric proximity switches, background suppression -- DC 00...00 mm Photoelectric proximity switches Dimensional drawing.. Laser LED, red light Adjustable background suppression 0 0.
More informationISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)
ISO 154071/ Distributors E Integrated electrical connection (ISO 15407/) B M1 connector (Automotive) A Single electrical connection (ISO 15407/1) A Pneumatic connection (ISO 15407/1) ISO 0 ISO Interface
More informationVALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm
BD ISO 15071/ Valves CHARACTERISTICS Ambient temperature Fluid Commutation system Max pressure Connections Nominal bore (mm) Nominal flow rate (Nl/min) Valve body Seals Spool Electropilot/Coil Voltage
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationmaintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000
Suction capacity in m /h m /h 20 2000 1000 0 00 2 200 1 100 10 700 0 0 400 00 200 100 0 100 200 00 400 0 0 700 800 900 1000 1100 Suction pressure auge pressure mbar ELMO- vacuum pumps and compressors convey
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationW 34: Sensor technology that does justice to demanding requirements
KD0_W_en.qxd.0.00 : Uhr Seite W Photoelectric switches Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches W : Sensor technology that does justice to
More informationDifferential indicators
Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively
More informationFacts and figures MULTILIFT SELECT 15
Facts and figures MULTILIFT SELECT 15 www.arburg.com MULTILIFT SELECT 15 Technical data min. 180 Stroke Z-axis Stroke X-axis Clamping face fixed mould platen 220 E A D K Stroke Y axis 195 B 2) C 157 P
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More information2/2-3/2 POPPET VALVES FOR VACUUM (1/8"-6/4") Series AG
2/2/2 POPPET VLVES FOR VCUUM (1/"/") Series G G / 1/2 complete range: / / G/ G/ 1/2 Original Univer poppet system appreciated for decades Servoassisted version complete range of solenoid valves and valves
More informationDBS315 1-phase SIDE CHANNEL BLOWERS
DBS15/ 1-phase DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More information4 Way Reversing Valve
STANDARD 4 Way Reversing Valve SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and
More informationG_Series. Gas Ring Blowers US Edition
_Series as Ring Blowers US Edition History In May 2002 the Nash Engineering Company, USA, and elmo vacuum technology mbh, ermany, formerly a Siemens subsidiary, merged to create a global leader in vacuum
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More information5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3
/ - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationSize A DIN EN
Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female
More informationPascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure
DATASHEET Pascal ET Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure - electrical signals (ma, mv, V, ) - temperature (TC and
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationD i s t a n ce Sensor DS 60
D i s t a n ce Sensor DS 0 T E C H N I C A L D E S C R I P T I O N Distance Sensor DS 0 Application Field The DS 0 distance sensors operate according to the principle of time of flight measurement. The
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More information2-way proportional throttle valve for block installation
-way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features
More information2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.
2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY
ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY www.abb.com/transformercomponents The information contained in this document is for general information
More informationPumps type MP Motor pump combination for mounting into tanks for on/off service
Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationFlow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min
RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division
More informationMRH. Return Filters RETURN FILTER
MRH Return ilters RETUR ILTER Return ilters MRH MRH MPa (0 bar) Port sizes: / / low rates:.00 l/min TECHICAL ATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa ( bar) ursting pressure: 6 MPa
More informationSolenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valves EVR 2 g 40 NC/ NO New with Steel cover design EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationHVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy
HVM 6 Page /4 Elektrohydraulic Servovalves Typ HVM 6 Symbol A B P T L Special features: high reliability easy service robust construction high dynamic response relatively insensitive to contamination variable
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationPumps type MP Motor pump combination for mounting into tanks for on/off service
Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 00 H Delivery flow Pressure p max max.
More informationPN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings
I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationElectric amplifiers. RE 30044/02.12 Replaces: Type VT-VRPA X/V0/RTS-2STV. Component series 2X 1/8
Electric amplifiers RE 30044/02.12 Replaces: 11.02 1/8 Type VT-VRPA1-527-2X/V0/RTS-2STV Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram
More information4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)
4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) Type 4WRL10...25 Sizes (N) 10, 16, 25 Unit series 3 Maximum working pressure P,, 350
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationOperating instructions Pressure sensor PN / / 2007
Operating instructions Pressure sensor PN42 704298 / 00 0 / 2007 Contents afety instructions... 3 2 Function and features... 4 3 Function... 5 3. witching function... 5 4 Installation... 5 5 Electrical
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationDirectional spool valve type SWPN Nom. size 6 or 10 conforming DIN
Directional spool valve type SWPN Nom. size 6 or 10 conformg DIN 24 340 Max. pressure Max. flow = 350 bar = 150 lpm 1. General The valves illustrated here are directly actuated directional spool valves
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20
DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationDifferential Pressure Switch
Features Using piezoresistive pressure sensor, which is compensated and aged well; high accuracy, quick response; Amplifier circuit driving switch relay; relay value could be set freely between zero and
More informationALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16
LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12
BCT61 DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More informationMADILL MBT GRAPPLE RETURN TO INDEX
MADILL MBT GRAPPLE RETURN TO INDEX MBT CONTROL VALVE Additional Parts Breakdown for: - Outrigger Sections - Rotate Section - End Plate E 00- page Valve section Basic element without additional functions
More informationALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16
DESCRIPTION Dutair BCT-series aluminium centrifugal fans with open die-cast aluminium impellers and forward curved blades are suitable for material transport and high pressure applications. The asynchronous
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationBenefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories
D a t a s h e e t T o r q u e T r a n s d u c e r S e r i e s M ( 2 N m 1 0 0 0 0 N m ) Benefits/Application For static and dynamic moments Non-rotational construction Very high-cycle fatigue resistant
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationDisplay counter electromechanical
Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical
More informationair and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2
Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationRotary modules.
Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More informationDigital AC Motors MHD
Digital AC Motors MHD090 8-1 8 MHD090 8.1 Technical Data Description Symbol Unit MHD090B-035 Type of cooling Natural Natural Surface Liquid Motor overtemperature 60 K 100 K 60 K/100 K 60 K/100 K Electric
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More informationAir Amplifers/Blowers
To meet a wide range of applications, air velocity and air flow are field adjustable to compensate for the pressure level supplied. CDF air amplifiers can achieve amplification ratios as high as 4:1 (output
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationSolenoid valve Types EVR 2 - EVR 40
Data sheet Solenoid valve s EVR 2 - EVR 40 EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. EVR valves are supplied complete or as
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More information