Protected. Main specifications. Additional specifications. Product adaptations

Size: px
Start display at page:

Download "Protected. Main specifications. Additional specifications. Product adaptations"

Transcription

1 Protected Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard stable lever positions stable plunger positions Function Connections I (changeover) W I (changeover) W - W R (normally closed) W - W - W3 C (normally open) W - W - W3 Electrical characteristics Rating nominal / 0 V AC (A) Rating thermal / 0 V AC (A) Mechanical characteristics Maximum operating force (N) Min. Release force (N) - - Tripping point (mm).4 ± Min. overtravel (mm) Mechanical life (operations) Max. permitted overtravel force (N) Rest position max. (mm) differential travel (mm) 0. ± Ambient operating temperature ( C) Contact gap (mm) 0.4 x 0.4 x 0.4 x Weight (g) Additional specifications # Components Material - Case : polyamide UL94V (83 06) - Contacts : nickel silver Levers - Mild steel (zinc) - Roller : polyamide - Adjusting screws : self-retaining - Plates : iridescent passivated mild steel (zinc) NB : Fixing holes for these microswitches have metal ferrules. Product adaptations Special levers Reinforced spring Special contacts Approvals : UL - cul 8 To order, see page

2 Principles Double break changeover switch Curves Operating curve for types / 4 / L { R = ms ~ cos ϕ = 0,8 0, 0, 0, V 0V~ 380V~ B Number of cycles C Resistive circuit D Inductive circuit E Mechanical life limit F Current in Amps Dimensions Product B OL = 0.6 C Ø Depth. Connections W screw W solder W3 for 6.3 mm clips 9

3 Actuators A B E Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Q B9 V3 F Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Mounting accessories O -pole side K -pole vertical Y Side plate H Horizontal single-pole Unless indicated, the thickness of plates is. mm 60

4 Actuators AR49 BR47 ER47 Q V3 R. B9 Operating force - max. N Release force - min. N Pre-travel - max. mm Differential travel mm. ±0.9. ±0.9. ±0.9.0 ± ±0. 0. ±0. Total travel max. mm Except where otherwise indicated, the flat and roller levers are mounted as shown in the dimensional drawings (mounted on the left). Mounting accessories Y Side plate HHorizontal single-pole O -pole side K -pole vertical Other information Mounting - Operation See basic technical concepts 6

5 Protected Double break switching Front connections Options for operation in stable positions Choice of actuators and fixing positions Main specifications Outputs on front face Function Connections I (changeover) W R (normally closed) W C (normally open) W Electrical characteristics Rating nominal / 0 V AC (A) Rating thermal / 0 V AC (A) 7. Mechanical characteristics Maximum operating force (N) 4 Min. Release force (N) Tripping point (mm) Min. overtravel (mm) 0.7 Mechanical life (operations) 0 7 Max. permitted overtravel force (N) 0 Rest position max. (mm).7 differential travel (mm) 0. ±0. Ambient operating temperature ( C) Contact gap (mm) 0.4 x Weight (g) 8 Additional specifications # Components Material - Case : polyamide UL94V - Contacts : nickel silver Levers - Mild steel (zinc) - Roller : polyamide - Adjusting screws : self-retaining - Plates : iridescent passivated mild steel (zinc) NB : Fixing holes for these microswitches have metal ferrules. Product adaptations Special levers Reinforced spring Special contacts Approvals : UL - cul 6 To order, see page

6 Principles Double break changeover switch Curves Operating curve for type L { R = ms ~ cos ϕ = 0,8 0, 0, 0, V 0V~ 380V~ B Number of cycles C Resistive circuit D Inductive circuit E Mechanical life limit F Current in Amps Dimensions Product Connections W solder B OL = 0.6 C Ø Depth. Actuators A B E Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm 63

7 Q B9 V3 F Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Mounting accessories O -pole side K -pole vertical H Horizontal single-pole Unless indicated, the thickness of plates is. mm Actuators AR49 BR47 ER47 Q V3 R, B9 Operating force - max. N Release force - min. N Pre-travel - max. mm Differential travel mm. ±0.9. ±0.9. ±0.9.0 ± ±0. 0. ±0. Total travel max. mm Except where otherwise indicated, the flat and roller levers are mounted as shown in the dimensional drawings (mounted on the left ).. Mounting accessories H Horizontal single-pole O -pole side K -pole vertical Other information Mounting - Operation See basic technical concepts 64

8 Protected 83 Double break switching Rear-fixing via nut or clips Options for operation in stable positions Choice of actuators and fixing positions Main specifications Rear-fixing with a nut 83 0 Rear-fixing with clips 83 Function Connections I (changeover) W - W - W3 R (normally closed) W - W - W3 C (normally open) W - W - W3 Electrical characteristics Rating nominal / 0 V AC (A) Rating thermal / 0 V AC (A) Mechanical characteristics Maximum operating force (N) 4 4 Min. Release force (N) Tripping point (mm) Min. overtravel (mm) Mechanical life (operations) Max. permitted overtravel force (N) 0 0 Rest position max. (mm) - - Maximum differential travel (mm) 0. ±0. 0. ±0. Ambient operating temperature ( C) Contact gap (mm) 0.4 x 0.4 x Weight (g) 8 8 Additional specifications # Components Material - Case : polyamide UL94V - Contacts : nickel silver Levers - Mild steel (zinc) - Roller : polyamide - Adjusting screws : self-retaining - Plates : iridescent passivated mild steel (zinc) NB : Fixing holes for these microswitches have metal ferrules. Product adaptations Special levers Reinforced spring Special contacts Approvals : UL - cul 70 To order, see page

9 Principles Double break changeover switch Curves Operating curve for types L { R = ms ~ cos ϕ = 0,8 0, 0, 0, V 0V~ 380V~ B Number of cycles C Resistive circuit D Inductive circuit E Mechanical life limit F Current in Amps Dimensions Product Connections W screw W solder W3 for 6.3 mm clips 7

10 Actuators A B E Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Q B9 V3 F Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Actuators AR49 BR47 ER47 Q V3 R. B9 Operating force - max. N Release force - min. N Pre-travel - max mm Differential travel mm. ±0.9. ±0.9. ±0.9.0 ± ±0. 0. ±0. Total travel max. mm Except where otherwise indicated, the flat and roller levers are mounted as shown in the dimensional drawings (mounted on the left).. Other information Mounting - Operation See basic technical concepts 7

11 Protected 83 Double break switching Flush-mounted connections Options for operation in stable positions Choice of actuators and fixing positions Main specifications Flush-mounted connections 83 0 Function Connections I (changeover) W Electrical characteristics Rating nominal / 0 V AC (A) Rating thermal / 0 V AC (A) 7. Mechanical characteristics Maximum operating force (N) 4 Min. Release force (N) Tripping point (mm) Min. overtravel (mm) 0.7 Mechanical life (operations) 0 7 Max. permitted overtravel force (N) 0 Rest position max. (mm).7 differential travel (mm) 0. ±0. Ambient operating temperature ( C) Contact gap (mm) 0.4 x Weight (g) 4. Additional specifications # Components Material - Case : polyamide UL94V - Contacts : nickel silver Levers - Mild steel (zinc) - Roller : polyamide - Adjusting screws : self-retaining - Plates : iridescent passivated mild steel (zinc) NB : Fixing holes for these microswitches have metal ferrules. Product adaptations Special levers Reinforced spring Special contacts Approvals : UL - cul 66 To order, see page

12 Principles Double break changeover switch Curves Operating curve for type L { R = ms ~ cos ϕ = 0,8 0, 0, 0, V 0V~ 380V~ B Number of cycles C Resistive circuit D Inductive circuit E Mechanical life limit F Current in Amps Dimensions Product 83 0 B Connection C OL = 0.6 Actuators A B E Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm Q B9 V3 F Lever cross-section x 6.4 mm Lever cross-section x 6.4 mm 67

13 Mounting accessories O -pole side K -pole vertical H Horizontal single-pole Unless indicated, the thickness of plates is. mm Actuators AR49 BR47 ER47 Q V3 R, B9 Operating force - max. N Release force - min. N Pre-travel - max. mm Differential travel mm. ±0.9. ±0.9. ±0.9.0 ± ±0. 0. ±0. Total travel max. mm Except where otherwise indicated, the flat and roller levers are mounted as shown in the dimensional drawings (mounted on the left ).. Mounting accessories H Horizontal single-pole O -pole side K -pole vertical Other information Mounting - Operation See basic technical concepts 68

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

microswitches Low force

microswitches Low force 0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A

More information

SUBMINIATURE MICROSWITCHES - STANDARD

SUBMINIATURE MICROSWITCHES - STANDARD 0/08 SUBMINIATURE MICROSWITCHES - STANDARD VD - 87 Flexible leaf snap-action mechanism with wiping contacts Ratings from 0.0 A Vc to (6) A 0 Va and / hp -0 Va ENEC and curus approved up to +0 C Housing

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

SUBMINIATURE MICROSWITCHES - PREMIUM

SUBMINIATURE MICROSWITCHES - PREMIUM 0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

TF Series Miniature Snap-acting Switches

TF Series Miniature Snap-acting Switches Features/Benefits Broad range of operating forces Ratings up to 21 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics Portable tools Specifications

More information

TF Series Miniature Snap-acting Switches

TF Series Miniature Snap-acting Switches Features/Benefits Broad range of operating forces Ratings up to 21 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics Portable tools Specifications

More information

83132 / / Subminiature Double Break Switches... 3/ Subminiature Switches... 3/ Sealed Subminiature Switches...

83132 / / Subminiature Double Break Switches... 3/ Subminiature Switches... 3/ Sealed Subminiature Switches... SWITHES ND SENSOS SWITHES ND SENSOS Snap ction Switches: 8 / 8 / 8 Subminiature Double reak Switches.................. / 870 Subminiature Switches.......................................... /6 880 Sealed

More information

Subminiature Switches Series / /

Subminiature Switches Series / / Subminiature Switches Series 8 / 8 / 8 General specifications ayout Types - The NO and N circuits must both be of the same polarity. omponents Material - ase : glass filled polyamide - ontacts : silver

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD

DIM. A (+ 0,05 0,51) .135 ±.015 (3,43 ± 0,38) COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE 1/4-32 UNEF-2A THREAD Multi-Deck SERIES 0 SERIES 0 0." Diameter, / Amp, Standard, Military SR FEATURES Proven Quality in Thousands of Applications Gold-plated Contact System 0,,, 0 and 0 Angle Options MIL Qualified Versions

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Three methods of panel mounting: flat frame for flush with face or subpanel, snap-in, and PCB. Miniature Rockers Series M High insulating barriers increase isolation of circuits

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008 Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Display counter electromechanical

Display counter electromechanical Micro Display counter K 04... K 07, shock resistant 4-, 5-, 6- and 7 digit Micro adding counter High shock resistance Low power consumption; suitable for battery consumption small dimensions Large optical

More information

BVM3F & KB5F SERIES. Enter product codes ( 3)T E R M I N A L S QC

BVM3F & KB5F SERIES. Enter product codes ( 3)T E R M I N A L S QC witches K B 5 B V M 3 27.8 x 10.1 x 17.65mm BVM3F & KB5F ERIE Positive action switches with 3mm contact gap. P a rt Number Operating Forc e A c t u a t o r s B V M 3 F 450 c N P l u n g e r B V M 3 F Y

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

2.3. Rockers. Contents

2.3. Rockers. Contents . SVRSealed Vehicle SVRSealed Vehicle Rocker Contents Description SVRSealed Vehicle Above Panel Rocker Switch............... Below Panel Rocker Switch............... Technical Data and Specifications..........

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

C V S T B T 1 0 ( )

C V S T B T 1 0 ( ) SLIDE SINGLE SWITCHES TURN WIREWOUND ( mm TRIMMERS PITCH) -6/- -T 6 FEATURES Lowest profile design of. mm Fine pitch of mm Easy motion with knob height of 0. mm 6 Part Part name name Material Material

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Mounting kits for insulation of power transistors

Mounting kits for insulation of power transistors ounting kits for insulation of power transistors tel. 0..6.6.6 www.elitaliaweb.it fax 0.6.6.0.09 info@elitaliaweb.it ST STS ST 0 STS 0 for transistor TO TO TO 0 TO 0 version with mica wafer S with silicone

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses gr - 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment.

More information

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION Effective: January 2004 Supersedes, dated June 1998 APPLICATION QUALITY FEATURES Descriptive Bulletin 41-078INTL Flexitest Switch Assemblies Type The type FT-19R (standard length) and FT-19RX (extended

More information

General characteristics, Products

General characteristics, Products The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload

More information

DATA SHEET: TEMPOWER2 ACB

DATA SHEET: TEMPOWER2 ACB Electrical haracteristics to IE 097, IE 097 Type Series AMERE RATING(A) AR0SB Standard RATED URRENT (max) [I n ](A) JIS,IE, EN, AS NEMA, ANSI Marine NEUTRAL OLE AMERES FRAME (A) NUMBER OF OLES 3 RATED

More information

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S

7S SERIES. Relay module with forcibly guided contacts 6 A 7S S /0310 7S Relay module with forcibly guided contacts.12 with 2 pole (1NO + 1 N).14 with 4 pole (2 NO + 2 N and 3 NO + 1 N).16 with 6 pole (4 NO + 2 N) For safety applications, with class A forcibly guided contact

More information

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012 Replacement Parts List No. 055231000 Revision C 04/2012 Singer Incremental Comfort Systems K, EK 07-15 Vintage F Last Manufactured: 1976 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

SPF SERIES SOLAR FUSES

SPF SERIES SOLAR FUSES Vdc - A Specifications Voltage Rating VDC Amperage Rating,,,.,,,,, 0,,,,, Max. Interrupting Rating ka - A - A ka - A - A Time Constant ms Material Body: Melamine Caps: Copper Alloy Approvals UL - Listed

More information

Type Plunger Height x pitch Operating force (OF) Without ground terminal Flat type 4.3 x 6.5 mm General 0.98 N (100 gf) B3F-6000 B3F-6100

Type Plunger Height x pitch Operating force (OF) Without ground terminal Flat type 4.3 x 6.5 mm General 0.98 N (100 gf) B3F-6000 B3F-6100 Mechanical Key Switch (Ral) B3F- Taped Ral Switches Automatic mounting possible via general- ral taped component inserters. Conform to EIAJ RC 1008A Electronic Component Taping Dimensions. The same snap-action

More information

3D Drawing - CARIF 260 BSA

3D Drawing - CARIF 260 BSA D Drawing - CARIF 0 BSA DRAWING CODE DRAWING NAME NUMBER ASS000 Basement ASS00 Vice Base ASS00 Vice A ASS00B Vice B ASS00 Frame A ASS00B Frame B ASS000 Frame Cylinder A ASS000B Frame Cylinder B ASS000

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses PSC gr sizes 7x - 690 VAC Main characteristics 6,9 grb 71 PA 200 6,9 grb 73 TTF 1000 + MS7V1-5 UR Ferraz Shawmut PSC-gRB 690 VAC fuse-links provide maximum flexibility in equipment design and ultimate

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

Fig. 3. Actuator. Mounting Height. Color. Force. 160g. Gray g. Black g. Gray Fig.

Fig. 3. Actuator. Mounting Height. Color. Force. 160g. Gray g. Black g. Gray Fig. TACTILE PUSHBUTTONS Fig. Fig. Fig. Fig. Fig. Mounting Figure Circuit Poles/ Amps 0VAC/ Operating Actuator Actuator Height Color DC Force Style No. Function Throws VDC - Gray 60g PCB, Low Profile 0.69 0mA

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Introduction. Sub-Miniature Pushbutton Switches Snap action MILapproved Sealed or non-sealed Low operating force

Introduction. Sub-Miniature Pushbutton Switches Snap action MILapproved Sealed or non-sealed Low operating force SECTION B Introduction PUSHBUTTON SWITCHES Standard Pushbutton Switches Momentary and alternate action Ratings up to 40 amperes One and two pole configurations Single hole mounting Decorative actuators

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Issued August DATA SHEET. 3VT3 MCCB up to 630 A ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Rail Guide Modular Linear Actuators DSM

Rail Guide Modular Linear Actuators DSM Roller Guide Modular Linear Actuators DLM, DLVM Rail Guide Modular Linear Actuators DSM nookindustries.com toll-free (800) 32-7800 25 DLM 20, 60, 200 Linear Motor Drive Specifications Function: This unit

More information

16mm Size Metal Shaft Type

16mm Size Metal Shaft Type Potentiometer 6mm Size Type RK63 Series A wide range of versatility products applicable for various types of control. Typical Specifications Items Total tolerance Maximum operating voltage Total rotational

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

Masterpact. Installation recommendations

Masterpact. Installation recommendations 90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch

More information

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards

More information

Slide Switches, Vertical, Single or Dual Actuator

Slide Switches, Vertical, Single or Dual Actuator TSS Series Slide TSS Switches Series MATERIAL SPECIFICATIONS: Contacts...Copper w/gold plate over nickel Case Material...High temperature polyester (94-VO) Actuator Material...Polyester (94-VO) Terminals...Copper

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g. Ÿ 9-50-way std density Ÿ 15-78 way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g., 3W3, 5W5, 8W8) Ÿ Feed-through capacitor & pi filter constructions

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

Liste de pièces Lista de Piezas Parts List

Liste de pièces Lista de Piezas Parts List 0th Anniversary Liste de pièces Lista de Piezas Parts List 0 3-9 09 DEC 0 A 5 3 3 8 0 9 SINGER 0th Anniversary Pos Part No Description 0 0053 E CLIP-ON-WASHER 0 0 M PHILIPS SCREW 3 0 038 CRINKLE WASHER

More information

1-Gang Thermoset 2051 A, B, LA, V, W 2-Gang Thermoset 2052 A, LA, V, W 3-Gang Thermoset 2063 A, LA, V, W 4-Gang Thermoset 2064 A, LA, V, W

1-Gang Thermoset 2051 A, B, LA, V, W 2-Gang Thermoset 2052 A, LA, V, W 3-Gang Thermoset 2063 A, LA, V, W 4-Gang Thermoset 2064 A, LA, V, W Wallplates Decorator Screwless, Mid-Size and Standard Contemporary design, sleek elegant lines, and a multitude of material, size and color choices make the Decorator Style an easy choice. Decorator Opening

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

JTC TOOL. 1Dial Gauge

JTC TOOL. 1Dial Gauge 1ial Gauge ial Indicator is surely utilized at manufacturing sites where dimensional high accuracy is needed to be confirmed. The graduation (1- graduation ) depends on usage and Teclock offers kinds of

More information

30Vdc Series ELECTRICAL CHARACTERISTICS

30Vdc Series ELECTRICAL CHARACTERISTICS RLD P UF Series Devices 2009.10.07 The Radial Leaded devices (RLD Series), a polymer-based Positive Temperature Coefficient (PTC) device to protect electrical circuits against over-current conditions with

More information

Military Qualified 10AT Series Snap Action Precision Position Switches

Military Qualified 10AT Series Snap Action Precision Position Switches Military Qualified 10AT Series Snap Action Precision Position Switches FEATURES Stainless steel, hermetic seal construction Rated up to 4 amps, 30VDC MIL-PRF-8805 qualified Various mounting configurations

More information

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection

More information

V 12: Miniature photoelectric switches in M 12 housings

V 12: Miniature photoelectric switches in M 12 housings Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T

More information

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CONNECTOR SERIES SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 CONTENTS CLAUSE PAGE 1.0 SCOPE. 4 1.2 Description. 4 2.0 APPLICABLE DOCUMENTS

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

Tap Changer Type MHF III Specification, Assembly and Materials

Tap Changer Type MHF III Specification, Assembly and Materials Tap Changer Type MHF III Specification, ssembly and Materials Descriptions General Specifications Remarks available in one, two or three phase applications shaft length available in variable sizes connection

More information

Alco PA AA Diesel Set

Alco PA AA Diesel Set 30-15-1 30--1 Alco PA AA Diesel Set GL0901 PA A Unit ( lead ) Diesel Engine 1.) Shell ( blue, yellow, silver ) FC-000 *5.00 ( A unit )( Delaware & Hudson )( # 17 ) Shell ( orange, black, silver ) FC-001

More information

S W I TC H MICRO SWITCH TOGGLE SWITCH PUSH BUTTON SWITCH SLIDE SWITCH VOLTAGE SELECTOR SWITCH ROCKER SWITCH ROTARY SWITCH STRUCTURE TERMINAL SPRING

S W I TC H MICRO SWITCH TOGGLE SWITCH PUSH BUTTON SWITCH SLIDE SWITCH VOLTAGE SELECTOR SWITCH ROCKER SWITCH ROTARY SWITCH STRUCTURE TERMINAL SPRING S W I TC H TOGGLE SWITCH PUSH BUTTON SWITCH SLIDE SWITCH VOLTAGE SELECTOR SWITCH ROCKER SWITCH ROTARY SWITCH STRUCTURE SPRING MOVABLE CONTACTOR ACTUATOR AID TERMINAL TERMINAL (NO) M-CONTACT CASE/COVER

More information

9mm Size Metal Shaft Multi-ganged Type. Typical Specifications. Total resistance tolerance ±20% Maximum operating voltage

9mm Size Metal Shaft Multi-ganged Type. Typical Specifications. Total resistance tolerance ±20% Maximum operating voltage K09 9mm Size Multi-ganged 9.mm width potentiometer ideal for various s of control Typical Specifications Items Specifications tolerance ±% Maximum operating voltage 0V C, V DC Total rotational angle 3

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0 Class 0 CONTENTS Description Page R Miniature Plug-in Relays..................................... K Plug-in Relays.............................................

More information

Insulated shaft type with a wide variety of applications. Typical Specifications. Rating. Operating life. Operating temperature range.

Insulated shaft type with a wide variety of applications. Typical Specifications. Rating. Operating life. Operating temperature range. ECE ECD mm Size shaft type with a wide variety of applications Typical Specifications Items Specifications Rating Operating life Without detent With detent 0.m V DC m V DC,000 cycles 0,000 cycles (Lightest

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

S P E C I F I C A T I O N S

S P E C I F I C A T I O N S F I N E L I T E S P E R S O N A L L I G H T I N G S Y S T E M S P E C I F I C A T I O N S 2.5 0.8 A C T U A L S I Z E ld 3 W D E S K L A M P Initial illuminance values in footcandles calculated using LM79

More information

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2. 18 Angular Gripper Cam Style Rack & Pinion Style Series / Cam actuation style is now standardized! 2.8-1 18 Angular Gripper 18 Angular Gripper Series / Cam Style Rack & Pinion Style Series / Series MHY/Cam

More information

KLKd Series 10x38 FUSES

KLKd Series 10x38 FUSES KLKd Series 0x FUSES 0 VAC 0 VDC /0- A Fast Acting Description The KLKD fuse series is fast-acting with a high DC voltage rating. This family of Midget style fuses (0 x mm) is used in solar combiner boxes

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite REPAIR PARTS (2,3,4) Multi Zone Heat Pump Outdoor Unit 2MXS18GVJUAA 3MXS24JVJUAA 4MXS32GVJUAA nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

Data Sheet. DIP-Switch DAS. Technical Data. Dimensions. Order Number Configuration

Data Sheet. DIP-Switch DAS. Technical Data. Dimensions. Order Number Configuration DIP-Switch DS DIP-switch with to 0 positions Flat slides with protective foil or raised slides Contacts have self cleaning function Insulation resistance (at 00 VDC) Test voltage ( minute) switches (at.000

More information

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260

More information

USRA Steam Engine

USRA Steam Engine USRA Steam Engine --- 0-5- 0-5-0 0-57- 0-57-0 USRA --- Steam Engine (top section) Engine Parts.) Shell (Pennsylvania)(# 7) FB-00 *5.00 ( Brunswick green, Tuscan red & graphite ) ( gold numbers ).) Shell

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

FAST CHECK THICKNESS GAGE

FAST CHECK THICKNESS GAGE FAST CHECK THICKNESS GAGE Recommended for quick thickness checks of flat sheet materials and wide variety of small parts. Supplied with hardened steel gaging contacts, lifting levers, and clockwise continuous

More information