CDS. high density spring connection

Size: px
Start display at page:

Download "CDS. high density spring connection"

Transcription

1 CDS high density spring connection

2 DENSTY STANDARD 1A CDS DENSTY A A spring connection

3 CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this segment. The continuous demand for a greater number of poles and of smaller dimensions has led to the design and manufacture of the new CDS series, which offers single connectors with a maximum number of poles that occupy the same space of standard connectors with screw/spring connection. The compact spring connection enables the occupied space to be reduced and avoids using CRP solutions that require the use of special tools. STANDARD 1A CDS - DENSTY A poles poles +% poles 1 poles +% 1 poles poles +% poles poles +% poles poles +% poles poles +% CDS - poles CDS - 1 poles CDS - poles CDS - poles The new CDS series, which is an evolution as compared to the compact CKS series, offers the following advantages: - reater pole density as compared to existing connectors with screw terminals for enclosures of the same size - Possibility of using wires up to. mm (AW 1) and availability of a useful section 1. mm (AW 1) for flexible wires terminated with crimp ferrule - A screwdriver with a. x. mm blade is the only tool required to insert the wire into the contact or to open the spring connection - No special wire preparation other than stripping - An excellent fastening solution and a great resistance to strong vibrations - Allows conductivity tests under load to be carried out by inserting the probes in the screwdriver insertion hole, without uncoupling the inserts.

4 Electrical characteristics compliant with EN 1: - rated current: A - rated voltage: V - rated impulse withstand voltage: kv - pollution degree: The new inserts are available in standard versions with silver plated brass contacts and can be used within a temperature range of - C/+ C. The insertion of the screwdriver is facilitated by the particular shape of the hole, which ensures that the operation is always performed correctly. Screwdriver slots, for the opening of s Slots for conductors t is possible to insert in the front area the new that enables the polarisation of inserts in a wide range of combinations. This means that it is possible to install side by side identical connectors with different functions. The new s can also be used in combination with oder CR / CR / CR / CR metal pins instead of insert fixing screws in order to increase the number of possible combinations. Each position of the coding pin used on the female insert must correspond to an unused position on the male insert. The required number of coding pins, depending on the size of connectors, and the maximum number of possible codings is shown in the following table. CDS series - Coding with CR CDS pins Size of Slots for coding pins Required Possible codings connectors () = male insert coding pins for () = female insert each coupling P+m () + () - (*) = 1P+m () + () - = P+m () + () - = P+m 1 () + 1 () = 1. (*) This excludes the two codings where all the coding pins are on one side only (male or female insert) because they are ineffective.

5 conductor connections spring connection contacts inserts series CDS No. of poles 1) main contacts + m, 1,,, (), () auxiliary contacts -- description rated current ) EN 1 pollution degree EN 1 pollution degree A rated voltage V rated impulse kv withstand voltage pollution degree rated voltage V/V rated impulse kv withstand voltage pollution degree inserts series: CDS n this layout the wires are connected to the female and male insert contacts by means of a spring terminal. This type of connection offers the following advantages: - no special wire preparation - a screwdriver with a. x. mm blade is the only tool required to insert the wire in the contact - offers an excellent fastening solution and a great resistance to strong vibrations - allows rigid and flexible wires with sections between.1 and. mm to be used (both with non-prepared conductors and those prepared with ferrule) - allows conductibility tests under load to be carried out through the screwdriver insertion section, without splitting the insert - greatly reduces insert preparation and cabling times contact resistance insulation resistance 1 mω Ω ambient temperature limit min - ( C) max + degree of protection with enclosures P, P, P, P, PK (according to type) without enclosures P conductor connections spring conductor cross-section mm.1 -. (for wires with crimped ferrule, usable section: up to 1. mm (AW 1) AW - 1 mechanical endurance (rating cycles) 1) Polarities shown in brackets may be achieved by using two inserts in their own double housings. ) Please check the insert load curves to establish the actual maximum operating current according to the ambient temperature..x. mm

6 A A 1 C C CDS poles + m A - V size. C-TYPE P/P * C P stainless steel lever... * V-TYPE P/P stainless steel lever - * T-TYPE P insulating... * JE zinc-plated steel lever... - * hoods... - * W-TYPE for aggressive environment.. * EC... * central lever * P... - * LS-TYPE... - ** panel supports: CO... - * * refer to catalogue page CN. ** refer to catalogue page LS-TYPE description part No. female inserts with female contacts CDS male inserts with male contacts CDS - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles diagram CDS poles 1, mm 1 1, mm, mm 1, mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm.

7 A 1 C D E CDS 1 poles + m A - V size. C-TYPE P/P... - * C P stainless steel lever... * V-TYPE P/P stainless steel lever - * T-TYPE P insulating... * JE zinc-plated steel lever * hoods... - * W-TYPE for aggressive environment.. * EC... * central lever... - * P * LS-TYPE... - ** panel supports: CO... - * * refer to catalogue page CN. ** refer to catalogue page LS-TYPE description part No. female inserts with female contacts CDS 1 male inserts with male contacts CDS 1 - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles diagram CDS 1 poles 1 1, mm 1, mm, mm A D C E , mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm.

8 A A 1 C D 1 E E CDS poles + m A - V size. C-TYPE P/P... - * C P stainless steel lever... * V-TYPE P/P stainless steel lever - 1 * T-TYPE P insulating... * JE zinc-plated steel lever... - * hoods * W-TYPE for aggressive environment.. 1 * EC... * central lever... - * P... - * LS-TYPE... - ** panel supports: CO... - * * refer to catalogue page CN. ** refer to catalogue page LS-TYPE description part No. female inserts with female contacts CDS male inserts with male contacts CDS - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles. diagram CDS poles 1 1, mm 1, mm, mm 1 1 C D , mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm.

9 1 L L N N O O 1 P P 1 CDS poles + m A - V size. C-TYPE P/P... - * C P stainless steel lever... * V-TYPE P/P stainless steel lever - * T-TYPE P insulating... * JE zinc-plated steel lever... - * hoods * W-TYPE for aggressive environment.. * EC... 1 * central lever... - * P... - * LS-TYPE... - ** panel supports: CO... - * * refer to catalogue page CN. ** refer to catalogue page LS-TYPE description part No. female inserts with female contacts CDS male inserts with male contacts CDS - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles diagram CDS poles 1 1, mm 1, mm, mm 1 1 A D C E A C D E 1, mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm.

10 a b c d e f g g h h i 1 A E 1 i 1 CDS poles + m A - V size. C-TYPE P/P... - * W-TYPE for aggressive environment.. * * refer to catalogue page CN. description part No. part No. female inserts with female contacts, No. (1-) and (-) CDS CDS N male inserts with male contacts, No. (1 ) and (-) CDS CDS N - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles. diagram CDS poles 1 1, mm 1, mm, mm 1 a b d c e f C D A C D E 1, mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm.

11 1 1 b e f A C 1 D 1 E 1 1 L L N N O O 1 1 P P 1 CDS poles + m A - V size. C-TYPE P/P... * W-TYPE for aggressive environment.. * * refer to catalogue page CN. description part No. part No. female inserts with female contacts, No. (1-) and (-) CDS CDS N male inserts with male contacts, No.(1-) and (-) CDS CDS N - characteristics according to EN 1: A V kv - insulation resistance: Ω - ambient temperature limit: - C... + C - made of self-extinguishing thermoplastic resin UL V - mechanical life: cycles diagram CDS poles 1 1, mm 1, mm, mm 1 a c d g h i l m n o p A D C E a b c d e f g h i l m n o p 1, mm mm - AW - 1 up to 1. mm (AW 1) - conductors stripping lenght:... mm.x. mm. 1

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors. mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection

More information

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers

Blocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded

More information

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth

More information

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415

More information

Mineral-insulated thermocouples to DIN and EN

Mineral-insulated thermocouples to DIN and EN Data Sheet 90.1210 (90.1221) Page 1/7 s to DIN 43 710 and EN 60 584 for temperatures from -200 to +1200 C flexible sheath with shock-proof measuring insert protection tube diameter from 0.5mm fast response

More information

90 MCB range Modular circuit breakers for circuit protection

90 MCB range Modular circuit breakers for circuit protection MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400

More information

General characteristics

General characteristics General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

microswitches Low force

microswitches Low force 0/06 Subminiature MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A

More information

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N

File E28476 Vol. 7 Sec. 44 Page 1 Issued: Vol. 23 Sec. 18 Revised: Vol. 67 Sec. 4 and Report D E S C R I P T I O N File E28476 Vol. 7 Sec. 44 Page 1 Issued: 1990-08-07 Vol. 23 Sec. 18 Revised: 2014-04-18 PRODUCT COVERED: USR - Series SL.156 Connectors. D E S C R I P T I O N USR - SL-156 Connectors, Receptacle Part

More information

Protected. Main specifications. Additional specifications. Product adaptations

Protected. Main specifications. Additional specifications. Product adaptations Protected 83 06 Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard 83 06 0 stable lever positions 83 06 4 stable plunger

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

SUBMINIATURE MICROSWITCHES - PREMIUM

SUBMINIATURE MICROSWITCHES - PREMIUM 0/08 SUBMINIATUE MICOSWITCHES - PEMIUM V - 870 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed atings from ma Vc up to (6) A 0

More information

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages Single Module EN4165 ARINC 809 - BACC 65 EN4165 The New Standard Connector for Aircraft equipment and cabin systems. Advantages Light weight composite, modularity, color coded, push pull coupling are the

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

MCB NB1-63H Miniature Circuit Breaker

MCB NB1-63H Miniature Circuit Breaker NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

5SP and 5SY Supplementary Protection UL 1077

5SP and 5SY Supplementary Protection UL 1077 Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic

More information

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

ct m ive p 5/EC Thermal cut-outs

ct m ive p 5/EC Thermal cut-outs RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

Redline Unibis : the solution Circuit protection

Redline Unibis : the solution Circuit protection 2 circuits in 1 mo Redline Unibis : the solution ircuit protection Unibis compact Ms are one of the latest introductions in the Redline range and are developed to reduce the size of the distribution board

More information

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher Welcome Functionality and application of RTD Temperature Probes and Thermocouples Dipl.-Ing. Manfred Schleicher This presentation informs about the basics of RTD Temperature Probes and thermocouples Functionality

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of 0,000 V. and

More information

Linear measuring technology

Linear measuring technology Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

High Power Contacts - Up to 850A

High Power Contacts - Up to 850A 8 Series igh Power Contacts igh Power Contacts - Up to 850 esigned to meet the harshest military requirements where high power and shielding are needed. 3 aluminum shell sizes available Size 19 (450 max);

More information

Features of Uni-Thermo

Features of Uni-Thermo Pelti ier Device in the 21st Uni-Thermo Century Hi eliability NTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality Chart Peltier

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

EMT Set-Screw Connectors, Insulated

EMT Set-Screw Connectors, Insulated Insulated EMT Set-Screw Connectors EMT Compression Couplings TC722US TK114US TC724US TK111US Insulated EMT Compression Connector (TC7110US) Insulated EMT Set-Screw Connector (TC729US) EMT Set-Screw Coupling

More information

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG

CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Page 1 of 27 CONNECTORS, ELECTRICAL, RECTANGULAR, MICROMINIATURE, NON-REMOVABLE GAUGE 26 PCB PIN CONTACTS BASED ON TYPE 8MCG Issue 6 June 2018 Document Custodian: European Space Agency see https://escies.org

More information

Temperature Measurement

Temperature Measurement Temperature Measurement 157 12 Precise and reliable measurements even in aggressive liquids all probes are encapsulated with PTFE for maximum chemical resistance. PRODUCT TIPS Page 161: 143 PT100 Temperature

More information

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5 Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring

More information

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

SUBMINIATURE MICROSWITCHES - STANDARD

SUBMINIATURE MICROSWITCHES - STANDARD 0/08 SUBMINIATURE MICROSWITCHES - STANDARD VD - 87 Flexible leaf snap-action mechanism with wiping contacts Ratings from 0.0 A Vc to (6) A 0 Va and / hp -0 Va ENEC and curus approved up to +0 C Housing

More information

DATA RACK BUSBAR. Data Rack Busbar Systems A.

DATA RACK BUSBAR. Data Rack Busbar Systems A. Data Rack Busbar Systems 250...1000 A www.eae.com.tr Overview Overview To power the mission critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System

More information

TeSys circuit-breakers

TeSys circuit-breakers Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the

More information

PRODUCT SPECIFICATION 1 SCOPE APPLICABLE STANDARDS CATALOG NO. STRUCTURE..3 4 CONNECTOR SHAPE, DIMENSIONS AND MARTERIALS..

PRODUCT SPECIFICATION 1 SCOPE APPLICABLE STANDARDS CATALOG NO. STRUCTURE..3 4 CONNECTOR SHAPE, DIMENSIONS AND MARTERIALS.. 1 of 1 A Table of Contents: 1 SCOPE.. 3 2 APPLICABLE STANDARDS..... 3 3 CATALOG NO. STRUCTURE..3 4 CONNECTOR SHAPE, DIMENSIONS AND MARTERIALS..3 5 ACCOMMOD CONDUCTORS (CIC).....3 6 PACKAGING CONDITION........3

More information

Technical Instructions 5020.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions 5020.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm Specification 12 ½''' Dimensions and battery ø Total 28.60 mm ø Case fitting 28.00 mm Movement height 4.40 mm Movement rest 0.60 mm Height of stem 1.90 mm Stem: Thread / Distance 0.90 mm / 0.90 mm Battery

More information

Features of Uni-Thermo

Features of Uni-Thermo Long-life. High reliability Uni-Thermo Peltier Device in the 1st Century CONTENTS Comparison with a Conventional Peltier Device. The Result of Operating Reliability Test Peltier Device Uni-Thermo Quality

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics 0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

S R O T C U D IN & MYRRA

S R O T C U D IN & MYRRA TRANSFORMERS & INDUCTORS MYRRA...Of course! TECHNICAL INFORMATION RATED PRIMARY OLTAGE () This is the supply assigned to the transformer by the manufacturer. RATED SECONDARY OLTAGE () This is the secondary

More information

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-22885/77F 2 August 2018 SUPERSEDING MIL-PRF-22885/77E 25 April 2013 PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH BUTTON, ILLUMINATED, 4-LAMP, 0.75 SQUARE, 7.5 AMPERES, AND LOW LEVEL

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

fischer connectors General Catalogue Edition 5.2

fischer connectors General Catalogue Edition 5.2 fischer connectors Edition. General Catalogue SUMMARY Ordering Information Mechanical Specifications Electrical Specifications Thermocouple Connectors Part number system and definitions, Body styles Coaxial,

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per

More information

Analogue Meters CQ2x07 series

Analogue Meters CQ2x07 series Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

Technical Instructions 4003.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions 4003.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm Specification 12 ½''' Dimensions and battery ø Total 28.60 mm ø Case fitting 28.00 mm Movement height 4.40 mm Movement rest 0.60 mm Height of stem 1.90 mm Stem: Thread / Distance 0.90 mm / 0.90 mm Battery

More information

K04 TYPE -40 C +85 C 20000H

K04 TYPE -40 C +85 C 20000H K04 TYPE -40 C +85 C 20000H Extended life. Surge-proof capacitor in aluminium can with insulation sleeve. To be mounted with ring clips or with threaded stud. Designed for high resistances to voltage spikes.

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

TF Series Miniature Snap-acting Switches

TF Series Miniature Snap-acting Switches Features/Benefits Broad range of operating forces Ratings up to 21 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics Portable tools Specifications

More information

Non-Contact Safety Systems CMS

Non-Contact Safety Systems CMS Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs

More information

CS Series. Capacitance Type. Type. Proximity Sensor. Features

CS Series. Capacitance Type. Type. Proximity Sensor. Features INFORMATI Series Features Capacitance Type - Metal cylinder/resin cylinder/square type - Non-metal objects such as wood, paper, plastic and water can be detected. - The operating distance is adjustable

More information

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations Test Report issued under the responsibility of: TEST REORT IEC/EN 60898-1 Circuit-breakers for over current protection for household and similar installations Report Reference No.... : 130100913SHA-004

More information

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324

Our Most Important Connection is with You. SECTION 8. Quick-Lock: QMA / WQMA / QN / QRE R123 / R123W / R164 / R324 SECTION 8 Quick-Lock: QM / WQM / QN / QRE R123 / R123W / R164 / R324 Contents QM and WQM Introduction... 8-4 to 8-5 Characteristics... 8-6 to 8-7 QM plugs and jacks... 8-8 to 8-9 QM receptacles...8-9 to

More information

Mounting kits for insulation of power transistors

Mounting kits for insulation of power transistors ounting kits for insulation of power transistors tel. 0..6.6.6 www.elitaliaweb.it fax 0.6.6.0.09 info@elitaliaweb.it ST STS ST 0 STS 0 for transistor TO TO TO 0 TO 0 version with mica wafer S with silicone

More information

SIM Mono Module Push Pull Connectors

SIM Mono Module Push Pull Connectors SIM Mono Module Push Pull Connectors EN RINC 809 Immeuble le Doublon avenue Dubonnet 90 COURBEVOIE Cedex FRNCE Version. Tel : (0) 9 0 0 00 Fax : (0) 9 0 0 0 www. amphenol-airlb. fr PRESENTTION PRT NUMBERING

More information

Technical Instructions cal D. Specifikation 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions cal D. Specifikation 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm Specifikation 12 ½''' Dimensions and battery ø Total 28.60 mm ø Case fitting 28.00 mm Movement height 4.40 mm Movement rest 0.60 mm Height of stem 1.90 mm Stem: Thread / Distance 0.90 mm / 0.90 mm Battery

More information

KTY-84. Product information for which Carbex bears no responsibility is provided by the manufacturer.

KTY-84. Product information for which Carbex bears no responsibility is provided by the manufacturer. The KTY 84 is a temperature-dependent semi-conductor with a positive temperature coefficient. Typical for these sensors is the monitoring of temperatures and limit values in the field of industrial metrology.

More information

Technical Instructions 4210.B. Specification 11 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Technical Instructions 4210.B. Specification 11 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm Specification 11 ½''' Dimensions and battery ø Total 28.60 mm ø Case fitting 28.00 mm Movement height 4.40 mm Movement rest 0.60 mm Height of stem 1.90 mm Stem: Thread / Distance 0.90 mm / 0.90 mm Battery

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I P N = 4, 6, 12, 15 A Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information