2-2. Bulletin 140M Motor Protection Circuit Breakers. Product Overview. Table of Contents. Standards Compliance. Certifications. General Information
|
|
- Jacob Benson
- 6 years ago
- Views:
Transcription
1 Bulletin 0M Motor Protection Circuit Breakers Product Overview Bulletin 0M Motor Protection Circuit Breakers Current Rane 0. 0 A UL Listed for Motor Loads Short Circuit Protection Overload Protection Visible Trip Indication Hih Current Limitin Hih Switchin Capacity The Bulletin 0M Motor Protection Circuit Breakers provide short circuit and overload protection for individual motor loads. Factoryinstalled internal accessories make installation and wirin easy. Table of Contents Product Selection Motor Protection Circuit Breakers... - Approximate Dimensions... - Standards Compliance IEC/EN 0-, -, --, -- IEC/EN 00- CSA, C. No. UL 0 UL (I-, J-, L-Frame) Certifications CE Marked culus Listed (File No. E, NLRV(); E0, NKJH(); E, DIVQ();) CCC CSA Certified ATEX General Information Motor Protection Circuit Breakers may provide the followin protective and control functions. Disconnect for Motor Branch Circuit Branch-Circuit, Short-Circuit Protection (Manetic Protection) Overload Protection (Thermal Protection) Switchin (Manual) In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-Protected Combination Motor Controller. 0M-C, D and F Frames: The 0M-C, D and F frame Motor Protection Circuit Breakers may have culus Listins as Manual, Self-Protected Combination Motor Controllers and as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). When UL/CSA listed as Manual, Self-Protected Combination Motor Controllers, the 0M Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. At some hiher voltaes and currents (particularly at 00V), a few of the 0M-C, D and F frame devices are only UL/CSA Listed as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on pae - for the specific ratins of each Motor Protection Circuit Breaker. 0-CMN Frame: The 0-CMN frame Motor Protection Circuit Breakers are UL Listed/CSA Certified as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on pae - for the specific ratins of each Motor Protection Circuit Breaker. 0M-I, J and L Frames: The 0M-I, J and L frame Motor Protection Circuit Breakers are culus Listed as Circuit Breakers as shown in the table on pae -. In these cases, the 0M Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. For further details on the proper application of Motor Protection Circuit Breakers, please see the diarams on the followin paes. - Publication A-CA00A-EN-P
2 Bulletin 0M Motor Protection Circuit Breakers Catalo Number Explanation Cat. No. Explanation Examples iven in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalo number. 0M C E A KN CC GJ a b c d e f h 0M C D F I J L a Bulletin Number Motor Protection Circuit Breakers (MPCBs) b Frame Size and Ratin A A A 0 A 0 A 00 A and 00 A Interruptin Ratin / Breakin Capacity Normal Break Hih Break Protection Type E Adj Thermal/ Fixed Ma ( x I n ) T Adj Thermal / Fixed Ma (...0 x I n ) Current Rane Example A A =. A = 0. B B =.0 B =. C C = C = D D = 0 D = 0 E E = 00 E = 00 c d e f,, h Factory-Installed Options f Miscellaneous See pae - Aux/Trip Contacts See pae - h UV and Shunt Trips See pae - - Publication A-CA00A-EN-P
3 Bulletin 0M Accessories For Use With Cat. No. Anti-Tamper Shield Provides protection aainst inadvertent adjustment of the current settin pcs/pk 0M-C, D, F 0M-C-CA Lockable Twist Knob For one padlock mm (/ in.) Ø shackle Can be locked in OFF position Lockin Ta Padlock attachment to the lockable handles Up to three padlocks mm (/ in.) Ø shackle 0M-C, D, F; 0U-D 0M-C-KN, 0M-C-KRY 0M-C-KN 0M-C-KRY 0M-C-M Padlockable Operatin Knob Accepts mm (/ in.) Ø padlock shackle up to three padlocks Permits padlockin in the off position Door Couplin Handle For padlocks mm (/ in.) in diameter IP Protection/Type,, X, Interlock override capability Can be modified for lockin in ON position Ships with couplin order extension shaft and leend plate separately Mountin depth (front of DIN Rail to front of enclosure door): - 0M-C:. mm ± mm (. in. ± / in.) - 0M-D:. mm ± mm (. in. ± / in.) - 0M-F:. mm ± mm (. in. ± / in.) - 0-CMN: mm +/- mm (. in. +/- / in.) Leend Plate Markin: "Hauptschalter" and "Main Switch" Markin: "Not-Aus" and "Emerency Off" Extension Shaft Cut to required lenth for mountin depth (front of DIN Rail to front of enclosure door): - 0M-C: mm (... in.) - 0M-D: mm (.0.. in.) - 0M-F: mm (... in.) - 0-CMN: 0 0 mm (... in.) Extension Shaft (Extended Lenth) Cut to required lenth for mountin depth (front of DIN Rail to front of enclosure door): - 0M-C: mm (.. in.) - 0M-D: mm (.0. in.) - 0M-F: mm (. 0. in.) - 0-CMN: 0 mm (.. in.) 0-CMN 0M-C, D, F 0-CMN 0M-C, D, F 0-CMN 0-CDN 0-CDRY 0M-C-DN, 0M-C-DRY, 0-CDN, 0-CDRY 0M-C-DN, 0M-C-DRY, 0-CDN, 0-CDRY 0-KN 0-KRY 0M-C-DN 0-CDN 0M-C-DRY 0-CDRY 0M-C-DFCN 0M-C-DFCRY 0M-C-DS 0M-C-DSL Coupler Included with Cat. Nos. 0M-C-DN and 0M-C-DRY 0M-C, D, F; 0U-D 0M-C-DNC IP Non-Metallic Enclosure Knockouts for M0 and M fittins Suitable for flexible cable with internal round wire or conduit when externally rounded around the outside of the enclosure (no UL/CSA approval) Handle Handle 0M-C 0M-C E-AYTG E-AYTJ Screw Adapter For screw arranement of a motor protection circuit breaker pcs/pk 0M-C, D, F; 0U-D 0M-C-N - Publication A-CA00A-EN-P
4 Bulletin 0M Modifications 0M Factory Modifications (Open) Note: For modifications add (option code _) for desired features to cat. no. Available in North America only. f Miscellaneous Frame Size KN() Lockable Knob C, D, F, CMN KRY() Lockable Knob C, D, F, CMN TE() Spacin Adapter for Self- Protected Starters (Type E) C, D, F MT STD Bus Bar Mount, Top C, D, F, H, CMN MU STD Bus Bar Mount, Universal J, K, L st st X Bottom Front Bottom Front Placeholder Only available on MCPs. J- and L-Frame MPCB only. Aux / Trip Contacts - C, D, F nd Aux / Trip Contacts - H, J, L nd X C R F N T Riht Side X Placeholder X Placeholder A N.C. C N.O. + N.C. B N.O. D N.O. C N.O. + N.C. E N.C. D N.O. K N.C. (SC+OL) + N.C. (SC) E N.C. L N.O. (SC+OL) + N.O. (SC) R N.C. + N.O. (SC+OL) M N.C. (SC+OL) + N.O. (SC) S N.O. + N.O. (SC+OL) N N.O. (SC+OL) + N.C. (SC) st Bottom Front Q Aux / Trip Contacts - CMN nd N.O. (SC) + N.C. (SC) Top Front X Placeholder X Placeholder C N.O. + N.C. K N.C. (OL) + N.C. (SC) D N.O. L N.O. (OL) + NO (SC) E N.C. M N.C. (OL) + N.O. (SC) Cannot be combined with option "h". N N.O. (OL) + N.C. (SC) Riht Side Placeholder N.O. + N.C. N.O. + N.C. (Overload Function) N.O. + N.C. N.O. (SC+OL) + N.C. (SC) N.O. + N.C. and N.O. + N.C. (SC+OL) st st Left Side h UV and Shunt Trips - C, D, F nd Voltae G Undervoltae Trip J V AC, 0 Hz P Left Side Only available on MCPs. Shunt Trip Aux / Trip Contacts - I, N nd K D C H F A T N B VC M ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE Riht Side X Placeholder X Placeholder C N.O. + N.C. C N.O. + N.C. F N.O. + N.C. F N.O. + N.C. N N.O. (SC+OL) + N.C. (SC) N N.O. (SC+OL) + N.C. (SC) T N.O. + N.C. and N.O. + N.C. (SC+OL) T N.O. + N.C. and N.O. + N.C. (SC+OL) V AC, 0 Hz 0V AC, 0 Hz V AC, 0 Hz 0V AC, 0 Hz 0 0V AC, 0 Hz 0V AC, 0 Hz V AC, 0 Hz 0 00V AC, 0 Hz 0V AC, 0 Hz and V AC, 0 Hz 00V AC, 0 Hz V AC, 0 Hz and 00V AC, 0 Hz V DC V DC V DC V DC V DC 0V DC V DC V DC 0V DC - Publication A-CA00A-EN-P
5 Bulletin 0M Specifications IEC Performance Data, Continued Cat. No. 0M-DE- Cat. No. 0M-FE- B B0 B C C C0 C C C C C C0 C C C Rated Operational Current, I e [A] Manetic Release Current [A] Switchin of Standard Three-Phase Motors AC- 0/0V [kw] /V [kw] V [kw] V [kw] Back-Up Fuses G, L, only if I cc I cu 0/0V [A] 00/V [A] /0V [A] V [A] V [A] Ultimate Short Circuit Breakin Capacity I cu 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] Rated Service Short Circuit Breakin Capacity I cs 0/0V [ka] /V [ka] /0V [ka] V [ka] V [ka] No back-up fuse required. Publication A-CA00A-EN-P -
6 Bulletin 0M Specifications General Data Rated Insulation Voltae U i Cat. No. 0M-C 0M-D 0M-F 0-CMN IEC, SEV, VDE 00 [V] 0 0 UL, CSA [V] Rated Impulse Withstand Voltae U imp Pollution deree Main circuits U imp /Overvoltae Cateory kv/iii kv/iii Auxiliary circuits U imp /Overvoltae Cateory kv/iii kv/iii Rated Frequency [Hz] 0/0 0 0 Utilization Cateory IEC 0- (Circuit breaker) A A IEC 0-- (Motor starter) AC- AC- Life Span Mechanical [operations] Electrical (I e max.) [operations] (up to A) 000 (up to 0 A) Switchin Frequency [operations/h] max. max. 0 Ambient Temperature Storae [ C] Operation [ C] - +0 Climatic resistance Moisture chane climate (000--0) C / % relative humidity and 0 C / % relative humidity, cycles Dry heat (00--) 0 C, relative humidity <0 %, days Moisture heat (00--) 0 C, relative humidity %, days Site Altitude [m] to 000 N.N. Protection Class IPX, when wired Resistance to Shock, Transport (00--) 0, ms, all axes 0, ms Resistance to Vibration, Opertion (00--) Rated Thermal Current I th up to 0 C ambient temperature [A] up to 0 C ambient temperature [A] Rated Supply Current I e [A] Dependence on Temperature 0 C [A] no reduction 0 C [A] no reduction 0 C [A] no reduction 0 C [A] % current reduction of the upper rated current I e Overload Protection Characteristics IEC 0-- Motor protection (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) IEC 0 Ambient Temperature Compensation [ C] Phase-loss Protection Differential release Trip class (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) fixed settin Manetic Release Release current (+/-0 %) fixed settin x I e max. (for 0M-CE, 0M-DE, 0M-FE, 0M-CN, 0M-DN, 0M-FN) x I e max. (for 0M-CT, 0M-DT, 0M-FT) I e max. = maximum values of settin ranes fixed settin x I e max. Total Power loss P v Circuit Breaker at rated load operatin temperature [W].. Main Disconnect Switch Application Yes, with accessories For utilization outside North America, assemblies (of products) shall comply to the IEC - requirements Application Conditions 0M manual motor starters are intended for use in closed areas without hazardous operatin conditions such as dust or explosive or corrosive ases. Enclosures of appropriate manner need to be in place to protect devices in such environments. Publication A-CA00A-EN-P -
7 Bulletin 0M Approximate Dimensions Cat. No. 0M-C, -D, -F Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin purposes. Cat. No. 0M-C Cat. No. 0M-D Mountin on mm DIN Rail Undervoltae/shunt trip Auxiliary contact (front mounted) Auxiliary contact (side mounted) - Publication A-CA00A-EN-P
Cat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More informationCat. No. 140M-F M-D8E-B
Bulletin 0M Motor Protection Circuit Breakers Product Selection Motor Protection Circuit Breakers Short Circuit Protection Standard Magnetic Trip ( x I e ) Motor Overload Protection Trip Class Rated Operational
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More information440V 500V V / / /2 12.
-26 Manual Motor Protectors March 0 B-Frame D-Frame Table -6. XTPR Rotary Manual Motor Protectors with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More information08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics
0/07 PKZ Tripping Characteristics Moeller HPL0-00/00 S-PKZ high-capacity contact module, SEA-PKZ contact module Normal switching duty AC-/00V kw A Rated output of three-phase motors 0...0 Hz. 7..... 0.7
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationIssued August DATA SHEET. 3VT3 MCCB up to 630 A
ssued August 9 DATA SHEET VT MCCB up to 6 A Based on Siemens Catalog V 6 8 Circuit breakers Switch disconnectors Technical specifications Specifications Type VT 76-AA6/6/56-AA, VT 76-AA6/6/56-AA Circuit
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationNon-Fused. Series DS2 IEC Non-Fused 12 Disconnect Switches. Accessories 15. Specifications 16. Dimensions 17. See Enclosed Disconnects 21
s e r i e s c3controls offers the most rugged, dependable Disconnect Switches that money can buy. From Panel/Base Mount to Door Mount with switch ratings from 16A - 125A, we ve got what you need. And,
More informationBETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationAnalogue Meters CQ2x07 series
Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement
More informationC60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka
C0N circuit breakers0 B, C and s IEC 0898: 000 A, IEC 097-: 0 ka Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of
More informationTeSys enclosed starters 2
Characteristics, references TeSys enclosed starters D..L. starters for motor control 0. to. kw with -phase thermal overload relay with protected phases Characteristics () Conforming to standards IEC 0--,
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More informationGPS1B. Characteristics. Technical performances
Thermal and magnetic protection PS Motor protection devices Standards/pprovals 097, 0972, 097 N V 00T 0//2 UL/S UL/cULus Shipping approvals: RN ureau Lloyd s Register Veritas ermanischer Lloyd haracteristics
More informationMiniature Circuit Breaker
Miniature Circuit Breaker SG-DPN I E C / E N 0 8 9 8-5 0 0 SG-DPN Applications Approval / Marking Function and Feature Integrate with switch phase and neutral in one module Protection against both overload
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection
More informationMasterpact. Installation recommendations
90 Installation recommendations Presentation Functions and characteristics 9 Dimensions and connection 5 Electrical diagrams 8 Operating conditions 92 Installation in switchboard 9 Door interlock catch
More informationH i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f
H i g h A m p e r a g e 2 5 t o 3 0 0 A M P T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 W a t e r p r o o f I g n i t i o n - P r o t e c t e d S A E & A B Y C C o m p l i a n t L E D T
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationTeSys contactors. TeSys D contactors. 690 V on a and c
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationMINIATURE MICROSWITCHES - PREMIUM
0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationMINIATURE MICROSWITCHES - PREMIUM
0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces
More informationTo order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle
otor protection relays - T - FWIT Since % of -phase motor failures are due to load problems or loss of phase, the CROUZET range of motor protection relays is indispensable! models give motor protection
More information40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES
DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More information90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230/400-240/415
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationBASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS
Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationSKF actuators available for quick delivery. Selection guide
SKF actuators available for quick delivery Selection guide A wide range of SKF actuators available for quick delivery Industrial actuator 24 Volt DC Load range 1 000 to 4 000 N Speed range 5 to 52 mm/s
More informationTime - timing relays 1 Industrial relays, solid state output, width 22.5 mm
haracteristics Zelio ime - timing relays Industrial relays, solid state output, width. mm Presentation 08 he E9 range of relays is designed for simple, repetitive applications with short and intensive
More informationSingle Phase Motors Technical Datasheets
Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and
More informationMotor Protection Circuit Breaker Series 8146/5-V27
> For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationSemiconductor (AC) fuses
gr 690 VAC sizes 000 to (full range) Ferraz Shawmut PROTISTOR NH grb 690 VAC fuselinks provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This
More informationRequest Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.
Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for INrail and wall mounting ilos up to ilos 2 up to los up to Order codes pplications pprovals / Marking ddon devices Performance INrail type and wall mounting type Main disconnector,
More informationSolenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil
Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for
More informationMoulded Case Circuit Breakers. Breaking capacity code: S:standard H:Higher type/r:current limiting type
TPact Moulded Case Circuit Breakers TPact Moulded Case Circuit Breaker. General Certificates: KEMA,CB; Electric ratings: AC0/0Hz, AC0V~90V DC0V~00V, A~0A; Standard: IEC/EN 097.. Type Designation TPact...
More informationNM1. Moulded Case Circuit Breaker NM1 P-084. Moulded Case Circuit Breakers. 2. Type designation. 1. General. 3. Classification N M 1- /
P0. Type designation N M / Type of Npole for P breaker* pplication: lank: for power distribution; : for motor protection elease type and accessory code (please refer to table on page 9) Number of poles
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More information90 MCB range Modular circuit breakers for circuit protection
MCB - MTC - MT - MTHP Technical data TYPE MTC MT MTC45 MTC60 MTC100 MT 45 MT 60 Rated current (In) (A) 2-32 6-32 6-32 6-40 1-63 Utilization category A A A A A Rated operational voltage (Ue) (V) 230 / 400
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationMiniatur Circuite Breakers (MCB)
Redline Miniatur Circuite Breakers (MCB) Technical data MCB s Series Standards Tripping characteristics Nominal current Calibration temperature Number of poles (#mod) Neutral pole protected Nominal voltage
More informationInstallation Equipment
Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester
More informationTEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations
Test Report issued under the responsibility of: TEST REORT IEC/EN 60898-1 Circuit-breakers for over current protection for household and similar installations Report Reference No.... : 130100913SHA-004
More informationFlexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008
Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB41-078 March 2008 FT-19R and FT-19RX FT-19R 3RU with Individual Clear Covers APPLICATION FEATURES The type FT-19R (standard length) and
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationPerformance. Standards. Technical data
ilos Loadbreak disconnectors for wall mounting ilos H up to 5 ilos 3 up to ilos 4 up to Order codes pplications pprovals / Marking ilos H34 ilos H ddon devices Performance Wall mounting Main disconnector,
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION RATED PRIMARY OLTAGE () This is the supply assigned to the transformer by the manufacturer. RATED SECONDARY OLTAGE () This is the secondary output assigned to the transformer when
More informationTeSys protection components Thermal-magnetic motor circuit-breakers GV2 ME and GV2 P
Dimensions GV ME and GV P Dimensions GV ME GV AX GV AD, AM, AN, AU, AS, AX, X Block GV AD, AM, AN Block GV AU, AS, AX GV AE b, X b GV MEpp GV MEpp () Maximum X Electrical clearance 0 mm for Ue y 0 V,,,
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM series I PN = 8, 15, 25 A Ref: HO 8-NSM, HO 15-NSM, HO 25-NSM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationPI3CH400 4-Bit Bus Switch, Enable Low 1.8V/2.5V/3.3V, High-Bandwidth, Hot Plug
1.8V/2.5V/3.3V, Hih-Bandwidth, Hot Plu Features Near-Zero propaation delay 5-ohm switches connect inputs to outputs Hih sinal passin bandwidth (500 MHz) Beyond Rail-to-Rail switchin - 0 to 5V switchin
More informationDistinctive Characteristics
Distinctive Characteristics Three methods of panel mounting: flat frame for flush with face or subpanel, snap-in, and PCB. Miniature Rockers Series M High insulating barriers increase isolation of circuits
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP/SP33 series I PN = 8, 15, 25 A Ref: HO 8-NP/SP33, HO 15-NP/SP33, HO 25-NP/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationNR2 Thermal Overload Relay
Contactors,, Starters. Type designation N - Current class Design sequence No. N Thermal Overload elay. General. Certificates: CE, KEM, UkrSEPO, GOST, CC, UL;. Electric ratings: C 0/0z, 90V, 0.~30;.3 Tripping
More informationFilm Capacitors. EMI suppression capacitors. Date: June 2018
Film Capacitors EMI suppression capacitors Date: June 2018 EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without
More information