GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Size: px
Start display at page:

Download "GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps"

Transcription

1 GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps

2 Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance range, MAGNA (D) and UPE(D) 5 Product range Product range Pump selection 7 Pump size 7 Operating conditions 7 Communication 7 Control mode 7 Operating conditions Operating conditions General recommendations Liquid temperature Ambient conditions Maximum operating pressure Minimum inlet pressure Electrical data 9 Sound pressure level 9 Functions Functions 1 Control modes (factory setting) 11 AUTOADAPT 11 Proportional-pressure control 11 Additional control and operating modes 11 Constant-pressure control 11 Constant-curve duty 1 Max. or min. curve duty 1 Automatic night-time duty (MAGNA only) 1 Additional operating modes of twin-head pumps 1 Readings and settings on the pump 13 Communication 13 Digital input 1 Digital output 1 Analog input 15 Bus communication 15 Functions of expansion modules 1 Construction Motor and electronic controller 17 Pump connections 17 Surface treatment 17 Material specification 17 Installation Mechanical installation 19 Insulation shells 19 Electrical connection 19 Cables 19 Wiring diagram Additional protection MAGNA 1 UPE(D) 1 Examples of connections Curve conditions Curve conditions 3 Technical data Base plates 5 Adapter 5 Blanking flanges 5 Union and valve kits 5 Union kits 5 Valve kits 5 Counter flanges 55 Insulation kits for UPE, heating 5 Insulation kits for MAGNA, heating 5 Insulation kits for MAGNA, air-conditioning 5 Expansion modules for MAGNA 5-5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1 (D), GENI module 57 Relay module 5 Expansion modules for MAGNA (D) 5-, 5-, 3-1, -1, 5-1, GENI module 59 LON module 59 R1 Control MPC Series Communication Interface Units (CIU) Order data MAGNA/UPE, cast iron 1 MAGNA, stainless steel 1 Further product documentation WebCAPS WinCAPS 3

3 Product data MAGNA, UPE MAGNA and UPE The MAGNA/UPE ranges of circulator pumps are specially designed for the following systems: heating systems up to 1 kw (Δt = C) domestic hot-water systems (stainless-steel or bronze pump housing) air-conditioning systems (+ C) up to 5 kw (Δt C) (MAGNA only). Duty range Data MAGNA (D) UPE(D) Maximum flow, Q 3 m 3 /h 1 m 3 /h Maximum head, 13 m 11.5 m Maximum system pressure 1 bar 1 bar Liquid temperature* + C to +95 C + C to +95 C * 11 C for short periods only, see Liquid temperature on page. Fig. 1 MAGNA/UPE pump ranges Characteristic features AUTOADAPT (MAGNA pumps only). Proportional-pressure duty. Constant-pressure duty. Constant-curve duty. Max. or min. curve duty. Parallel connection of pumps with Control MPC Series. No external motor protection required. Insulation shells are part of the single-head MAGNA pumps. TM Benefits Low noise level. Safe selection. Simple installation. Low energy consumption, all MAGNA pumps are energy class "A". In addition to this, the AUTO ADAPT function ensures energy savings for MAGNA pumps. Long life and no maintenance. External control and monitoring enabled via expansion modules. Applications eating systems Main pump. Mixing loops. eating surfaces. Air-condition surfaces (MAGNA only). The MAGNA/UPE circulator pumps are designed for circulating liquids in heating systems with variable flows where it is desirable to optimise the setting of the pump duty point. The pumps are also suitable for domestic hot-water systems. To ensure correct operation, it is important that the sizing range of the system falls within the duty range of the pump. The MAGNA/UPE is especially suitable for installation in existing systems where the differential pressure of the pump is too high in periods with reduced flow demand. The pump is also suitable for new systems where automatic adjustment of pump head to actual flow demand is required without using expensive bypass valves or the like. Furthermore, the pump is suitable for application in systems with hot-water priority as an external contact can immediately force the pump to operate according to the max. curve. 3

4 Product data MAGNA, UPE Pumped liquids Thin, clean, non-aggressive and non-explosive liquids, not containing any solid particles, fibres or mineral oil. If the pump is installed in a heating system, the water should meet the requirements of accepted standards on water quality in heating systems, e.g. the German standard VDI 35. In domestic hot-water systems, the pump should be used only for water with a degree of hardness lower than approx. 1 d. The pump must not be used for the transfer of inflammable liquids such as diesel oil and petrol. If the pump is not used during periods of frost, necessary steps must be taken to prevent frost bursts. Additives with a density and/or kinematic viscosity higher than those/ that of water will reduce the hydraulic performance. Whether a pump is suitable for a particular liquid, depends on a number of factors of which the most important are lime content, p value, temperature and content of solvents, oils, etc. GRUNDFOS MAGNA pumps can be used for pumping glycol/water liquids up to 5 %, see Operating conditions. Please note that glycol will reduce the hydraulic performance.

5 Product data MAGNA, UPE Type key MAGNA (D), UPE(D) Example UP E D -1 (F) (N) Type range UPE(D): MAGNA (D): Electronic control Twin-head pump Nominal diameter of suction and discharge ports (DN) Maximum head [dm] Flange connection N: Single-head pump housing of stainless steel B: Single-head pump housing of bronze Z: UPE(D) model E and future models Port-to-port [mm] Performance range, MAGNA (D) and UPE(D) p [kpa] MAGNA 5-1 MAGNA (D) -1 MAGNA 3-1 MAGNA - MAGNA 3- MAGNA 5- MAGNA (D) -1 MAGNA 5-1 MAGNA (D) 3-1 MAGNA (D) 5-1 UPE 1-1 FZ UPE(D) -1 FZ 5 5 MAGNA - MAGNA 3- MAGNA 5- MAGNA (D) MAGNA (D) 5- MAGNA (D) 5- MAGNA 3- MAGNA 5-1 Fig. Performance range Q [m³/h] Q [l/s] TM

6 Product range MAGNA, UPE Product range Supply voltage Port-to-port length Pipe connection Flange connection Data sheet 1 x 3- V 1 x 3 V [mm] 1" 1 1/" " PN /PN 1 PN PN 1 Page Single-head pumps MAGNA 5-1 MAGNA 5- N 1 MAGNA MAGNA 5- N 1 5 MAGNA 5-1 MAGNA 5- N 1 MAGNA MAGNA 3- N 1 7 MAGNA 3-1 MAGNA 3- N 1 MAGNA MAGNA 3- N 1 9 MAGNA 3- F 1 3 MAGNA MAGNA 5-1N 1 31 MAGNA MAGNA 3-1 N 1 3 MAGNA 3-1 F 33 MAGNA - F 3 MAGNA - F 35 MAGNA -1 F 3 MAGNA 5-1 F 37 MAGNA 3-1 F 3 MAGNA 3-1 FN 3 MAGNA -1 F 5 39 MAGNA -1 FN 5 39 MAGNA 5- F MAGNA 5- FN MAGNA 5- F 3 1 MAGNA 5- FN 3 1 MAGNA 5-1 F MAGNA 5-1 FN MAGNA 5-1 F 3 3 MAGNA 5-1 FN 3 3 UPE -1 FZ 3 UPE 1-1 FZ 5 5 Twin-head pumps MAGNA D -1 F MAGNA D 3-1 F 7 MAGNA D -1 F 5 MAGNA D 5- F 9 MAGNA D 5- F 3 5 MAGNA D 5-1 F 51 MAGNA D 5-1 F 3 5 UPED -1 FZ 3 53

7 Product range MAGNA, UPE Pump selection Pump size Selection of pump size should be based on ead Duty point required maximum flow maximum head loss in the system. Refer to the system characteristics to determine the duty point. See fig. 3. Operating conditions It should be checked whether the operating conditions are fulfilled, i.e. Fig. 3 System characteristic Flow TM 331 liquid temperature and ambient conditions minimum inlet pressure maximum operating pressure. BMS Communication The requirements for external control or monitoring of the pump should be considered, such as access to the following: Gateway GENI module speed control of pump or change of setpoint reading of pump data start/stop, fault indication or forced control to max. or min. curve. Note: The communication options depend on the pump type. Control mode In general, Grundfos recommends the factory setting which is suitable for most installations proportional-pressure control in systems with relatively great head losses constant-pressure control in systems with relatively small head losses. Control MPC Series Fig. Building management system with six pumps in parallel controlled via a Control MPC Series TM

8 Operating conditions MAGNA, UPE Operating conditions General recommendations MAGNA/UPE Water in heating systems Domestic hot water Water containing glycol Liquid temperature Ambient conditions Water quality according to local standards such as the German standard VDI 35 Degree of hardness up to 1 d Maximum viscosity = 15 mm /s (~ 5 % glycol at + C) Application Time MAGNA (D) UPE(D) Short periods +11 C +11 C General Continuously + C to +95 C + C to +95 C Domestic hot-water Continuously + C to + C - systems Ambient temperature during operation: C to + C Ambient temperature during storage/transport: -3 C to +55 C, MAGNA (D) Maximum operating pressure 1 bar. Minimum inlet pressure The following relative minimum pressures must be available at the pump inlet during operation: MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1 MAGNA (D) 3-1 F MAGNA (D) -1 F MAGNA (D) 5- F MAGNA (D) 5-1 F MAGNA (D) 5- F MAGNA (D) 5-1 F Liquid temperature 75 C 95 C Inlet pressure [bar] / [MPa].1 /.1.35 /.35.9 /.9 1. /.1 UPE(D) -1 FZ.5 /.5 1. /.1 UPE 1-1 FZ.5 /.5 1. /.1 Note: Actual inlet pressure + pump pressure against a closed valve must be lower than the maximum permissible system pressure. -1 C to + C, UPE(D) Relative air humidity: Maximum 95 %.

9 Operating conditions MAGNA, UPE Electrical data MAGNA/UPE Expansion module Sound pressure level MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1 MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 UPE(D) FZ Enclosure class IP (IEC 5) IP (IEC 5) IP (IEC 5) Insulation class F F External start/stop input Setpoint signals Signal output Bus input Supply voltage External potential-free switch. Screened cable. Maximum contact load: 5 V, 1 ma. External potential-free switch. Screened cable. Maximum contact load: 5 V, 1 ma. External potential-free switch. Screened cable. Maximum contact load: 5 V,.5 ma. GENI module GENI module Min. curve input External potential-free switch. Screened cable. Maximum contact load: 5 V,.5 ma. Input for analog -1 V signal External signal: -1 VDC. Maximum contact load: 1 ma. Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. GENI module Grundfos Communication Interface Unit (CIU) for: LON Modbus RTU BACnet MS/TP GSM/GPRS Profibus. Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. GENI module LON module Grundfos Communication Interface Unit (CIU) for: Modbus RTU BACnet MS/TP GSM/GPRS Profibus. Internal potential-free changeover contact. Screened cable. Maximum contact load: 5 VAC, A. Minimum contact load: 5 VDC, 1 ma. Grundfos GENIbus protocol. Screened cable. Lead cross section:.5-1 mm. Maximum cable length: 1 m. Grundfos Communication Interface Unit (CIU) for: LON Modbus RTU BACnet MS/TP GSM/GPRS Profibus. 1 x 3- V - 1 %/+ %, 5/ z, PE 1 x 3- V - 1 %/+ %, 5/ z, PE 1 x 3 V - 1 %/+ %, 5/ z, PE The pump requires no external motor protection. Earth leakage current I leak < 3.5 ma The leakage currents are measured in accordance with EN EMC EN 1-3. MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1 MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 UPE(D) Sound pressure level 3 db(a) 3 db(a) 3 db(a) 9

10 Functions MAGNA, UPE Functions MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1 MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1 Function incorporated. Expansion module required. MAGNA-LON interface required. Not recommended for air-conditioning systems. Communication Interface Unit (page ) required. GENI module (page 57) or GENI module (page 59) and Communication Interface Unit (page ) required. UPE(D) FZ Control modes (factory setting) AUTO ADAPT Proportional-pressure control Additional control and operating modes Proportional-pressure control Constant-pressure control Constant-curve duty Max. or min. curve duty Automatic night-time duty Additional operating modes of twin-head pumps Alternating operation Standby operation Readings and settings on the pump Operating indication Flow indication Setpoint Control mode Fault indication Communication Wireless remote control, R1 External digital input/output External analog input Bus via GENIbus protocol, RS-5 Bus via LonTalk protocol, FTT 1 Bus via BACnet MS/TP Bus via Modbus RTU Bus via GSM/GPRS Bus via Profibus 1

11 Functions MAGNA, UPE Control modes (factory setting) The pumps have been factory-set to AUTO ADAPT (MAGNA). proportional-pressure control (UPE). The setpoint is factory-set to half of the maximum pump head. The factory setting is suitable for most installations. AUTO ADAPT During operation, the pump automatically reduces the factory-set setpoint and adjusts it to the actual system characteristic. max. fac. auto_min A1 Fig. 5 AUTO ADAPT control set1 A 3 A set Note: Manual setting of the setpoint is not possible. When the control mode AUTO ADAPT has been activated, the pump will start at set1, corresponding to 5 % of its maximum head, and then adjust its performance to A 1. See fig. 5. When the pump registers a lower pressure on the max. curve, A, the AUTO ADAPT function automatically selects a correspondingly lower control curve, set. If the radiator valves close, the pump adjusts its performance to A 3. A 1 : Original duty point. A : Lower registered pressure on the max. curve. A 3 : New duty point after AUTO ADAPT control. set1 : Original setpoint setting. set : New setpoint after AUTO ADAPT control. fac. : MAGNA xx-:.5 m MAGNA xx-: 3.5 m MAGNA xx-:.5 m MAGNA xx-1: 5.5 m. auto_min : A fixed value of 1.5 m. The AUTO ADAPT control mode is a form of proportionalpressure control where the control curves have a fixed origin, auto_min. The AUTO ADAPT control mode is developed specifically for heating applications and not recommended for airconditioning systems. TM Proportional-pressure control The pump head is changed continuously in accordance with the flow demand in the system. The head against a closed valve is half the setpoint. set set Q Fig. Proportional-pressure control The proportional-pressure control is recommended in systems with relatively great head losses. Additional control and operating modes Grundfos offers additional control and operating modes to meet specific demands. The functions available depend on the pump type and the expansion module chosen. See overview of functions on page 1. Constant-pressure control The pump head is kept constant, independent of the water requirement. set Fig. 7 Constant-pressure control The constant-pressure control is recommended in systems with relatively small head losses. Q TM 995 TM

12 Functions MAGNA, UPE Constant-curve duty Requires the use of an R1 remote control. The pump can be set to operate according to a constant curve like an uncontrolled pump. If an external controller is installed, the pump is able to change from one constant curve to another, depending on the value of the external signal. Min. Fig. Constant-curve duty Max. Max. or min. curve duty The pump can be set to operate according to the max. or min. curve, like an uncontrolled pump. TM Automatic night-time duty (MAGNA only) When automatic night-time duty has been selected, the pump will change automatically between normal duty and night-time duty. Changeover between normal duty and night-time duty takes place as a result of the flowpipe temperature measured by an integrated temperature sensor. The automatic changeover to night-time duty takes place when the temperature sensor registers a flowpipe temperature drop of more than 1-15 C within approx. hours. The required temperature drop is a minimum of.1 C/min. Changeover to normal duty takes place without a time lag when the temperature has increased by approx. 1 C. Additional operating modes of twin-head pumps The following operating modes are available for twinhead pumps: Alternating operation Pump operation alternates every hours (UPE 5 hours). If the duty pump stops due to a fault, the other pump will start. Min. Max. TM Standby operation One pump is operating continuously. In order to prevent seizing-up, the other pump will start at a fixed frequency (every hours) and run for a short period. If the duty pump stops due to a fault, the other pump will start. Fig. 9 Max. or min. curves The max. curve mode can be used in periods in which a maximum flow is required. This operating mode is for instance suitable for hot-water priority. The min. curve mode can be used in periods in which a minimum flow is required. This operating mode is for instance suitable for manual night-time duty duty. 1

13 Functions MAGNA, UPE Readings and settings on the pump The control panel on the pump control box incorporates the basic functions for readings and settings. Communication Depending on pump type, MAGNA/UPE enables communication via wireless remote control, R1 connection to an external alarm device digital input/output analog input. Fig. 1 MAGNA (D) control panel TM Fig. 1 R1 remote control MAGNA/UPE is designed for wireless communication with the Grundfos R1 remote control. TM 9 Pos. Description 1 Buttons for setting of head. 3 Indicator lights for operating and fault indication. Symbol for indication of external control. Button for selection of control mode: AUTO ADAPT, proportional pressure, constant pressure and automatic night-time duty. Light symbols for indication of control mode and night-time duty. 5 Light fields for indication of head, flow and operating mode. 1 The R1 offers additional possibilities of setting and status displays for the pump. The R1 can be used for the following functions: reading of operating data reading of fault indications setting of control mode setting of.1 m head increments selection of external setpoint signal allocation of pump number making it possible to distinguish between pumps in connection with parallel operation via bus selection of function for digital input. The MAGNA/UPE has various inputs and outputs for external signals for forced-control functions. Some functions may require an expansion module. Grundfos GENIbus 3 TM Pos. Fig. 11 UPE(D) control panel Description Buttons for start/stop of the pump, setting of setpoint, control 1 mode, min. and max. curve. Light fields for indication of control mode and setpoint. 3 Indicator lights for operating and fault indication. Fig. 13 MAGNA with expansion module TM

14 Functions MAGNA, UPE Digital input The information on digital input applies to MAGNA pumps only. External start/stop The pump can be started or stopped via the digital input. Start/stop External forced max. or min curve The pump can be forced to operate on the max. or min. curve via the digital input. Q Q Max. curve Q Q Min. curve Q Normal duty Stop Normal duty Max. curve Normal duty Digital output The MAGNA pumps incorporate a signal relay with a potential-free changeover contact for external fault indication. The function of the signal relay can be changed from "Fault" to "Ready" or "Operating" mode with the R1. These pumps require expansion modules. The functions of the signal relay are as shown in the table below: Signal relay Fault signal 1 3 NC NO C 1 3 NC NO C 1 3 NC NO C Not activated: The electricity supply has been switched off. The pump has not registered a fault. Activated: The pump has registered a fault. Signal relay Ready signal 1 3 NC NO C 1 3 NC NO C 1 3 NC NO C Not activated: The pump has registered a fault and is unable to run. Activated: The pump has been set to stop, but is ready to run. The pump is ready to run or is running. Signal relay Operating signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 3 NC NO C run. 1 3 NC NO C Activated: The pump is running. The pump has registered a fault, but is able to run. Q Min. curve The function of the digital input is selected with the R1 remote control. 1

15 Functions MAGNA, UPE Analog input External analog control Requires an expansion module. Control of setpoint or speed via an external -1 V signal. m Min. curve 1 Max. curve Fig. 1 Example of -1 V control The analog input enables the following control modes: MAGNA/UPE In constant-curve mode, the pump is able to change from one constant curve to another depending on the value of the external signal. The internal controller is inactive in this mode. MAGNA In pressure control mode, the setpoint can be set externally within the range from the setpoint to the min. curve. The internal controller is active in this mode. At an input voltage lower than.5 V, the pump will operate according to the min. curve. Bus communication All MAGNA pumps can be fitted with a GENIbus interface module which is based on the RS-5 platform. See Accessories on page 57. UPE pumps have a built-in GENIbus interface. Bus communication enables control and monitoring of up to six single-head pumps operating in parallel from a building management system (BMS). The options are shown below: UPE Series FZ. See fig. 15. Grundfos MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1. See fig. 1. Grundfos MAGNA (D) 3-1, -1, 5-, 5-1, 5-, 5-1. See fig Setpoint/constant curve 7 U V TM BMS CIU Gateway CIU Fig. 15 UPE Series FZ in BMS systems CIU GENI module GENI module Fig. 1 MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1 in BMS systems LON module GENI module Gateway GENI module GENI module GENI module CIU GENI module GENI module GENI module BMS BMS GENI module Gateway GENI module GENI module GENI module MPC CIU MPC CIU MPC GENI module GENI module GENI module GENI module GENI module Fig. 17 MAGNA 3-1, -1, 5-, 5-1, 5-, 5-1 in BMS systems In order to select the correct CIU unit for the application in question, see Accessories on page. TM TM 77 1 TM

16 Functions MAGNA, UPE Functions of expansion modules Inputs/outputs incorporated With expansion module Function MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1 (D), 5-1 MAGNA (D) 3-1, -1, 5-, 5-1, 5-, Start/stop Signal relay Relay module GENI module GENI module LON module Start/stop Signal relay Start/stop Max. curve Min. curve -1 V analog input Twin-head pump control GENIbus Signal relay Max. curve Min. curve -1 V analog input Twin-head pump control GENIbus LonTalk protocol, FTT1 1

17 Construction MAGNA, UPE The MAGNA/UPE is of the canned-rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. The pump is characterised by the following: controller integrated in the control box control panel on the control box control box prepared for optional modules differential-pressure and temperature detection cast-iron, stainless-steel or bronze pump housing, UPE(D) with cast-iron pump housing only twin-head versions no external motor protection required. Motor and electronic controller The single-phase MAGNA pump incorporates a threephase - or -pole synchronous, permanent-magnet motor (PM motor). This motor type is characterised by higher efficiency than a conventional asynchronous squirrel-cage motor. Pump speed is controlled by an integrated frequency converter. Material specification MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1, 5-1 Pos. Component Material EN 1 Control box Composite PA or PC/ASA Stator housing Aluminium AlSi 1Cu O-rings EPDM rubber 3 Outer bearing ring Aluminium oxide Al O 3 Rotor can Stainless steel 1.1 Shaft Aluminium ceramics Al O 3 5 Thrust bearing Carbon MY 1 Bearing plate Stainless steel 1.31 Aluminium ceramics Inner bearing ring Al O 3 7 Impeller Composite Pump housing Cast iron GJL- or stainless steel. 1. Insulation shells* EPP * Insulation shells for heating applications and insulation shells for airconditioning are available as accessories, see Insulation shells on page 5. The single-phase UPE pump incorporates a threephase -pole asynchronous motor with integrated frequency converter. A differential-pressure and temperature sensor forms an integral unit. Pump connections Threaded pump connections to ISO /1. Flange dimensions to ISO 75-/BS5. Surface treatment The pumps are wet-varnished. Colour: NCS-5R. TM Fig. 1 MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1,

18 Construction MAGNA, UPE MAGNA 3-1, -1, 5-, 5-1, 5-, 5-1 Pos. Component Material EN 1 Control box Composite Stator housing Aluminium AlSi 1Cu O-rings EPDM rubber 3 Outer bearing ring Aluminium oxide Al O 3 /SiC Rotor can Stainless steel 1.1 Shaft Stainless steel Thrust bearing Carbon MY 1 Bearing plate Stainless steel 1.31 Inner bearing ring Aluminium oxide Al O 3 /SiC 7 Impeller Stainless steel 1.31 Pump housing Cast iron or stainless steel GJL5 1.3 Insulation shells* EPP * Insulation shells for heating applications, see Insulation shells on page 5. UPE XX-1 FZ Pos. Component Material EN 1 Control box Composite PP/35 % glass Stator housing Die cast aluminium, AlSi 3 Rotor can Stainless steel 1.51 Shaft Stainless steel Thrust bearing Aluminium oxide Al O 3 Inner bearing ring Carbon EC 93 7 Impeller Composite PES/3 % glass Pump housing Cast iron UNI ISO 15 Differential-pressure 9 and temperature sensor 1 Outer bearing ring Carbon EC Air vent plug Brass 1 Bearing support Cast iron O-rings EPDM rubber Insulation shells* EPP * Insulation shells for heating applications, see Insulation shells on page 5. Fig. 19 MAGNA 3-1, -1, 5-, 5-1, 5-, 5-1 TM TM 9 11 Fig. UPE XX-1 FZ 1

19 Installation MAGNA, UPE Mechanical installation MAGNA/UPE is for indoor installation. The pump must be installed with horizontal motor shaft. The pump may be installed in horizontal as well as vertical pipes. Arrows on the pump housing indicate the liquid flow direction through the pump. The liquid flow direction can be horizontal or vertical, depending on the control box position. The control box can be turned to various positions, depending on pump type. This is described in the installation and operating instructions. The pump must be installed in such a way that strain from the pipework is not transferred to the pump housing. The pump may be suspended direct in the pipes, provided the pipework can support the pump. If not, the pump must be installed on a mounting bracket or base plate. To ensure cooling of motor and electronics, the following must be observed: Place the pump in such a way that sufficient cooling is ensured. The temperature of the cooling air must not exceed C. Electrical connection The electrical connection and protection should be carried out in accordance with local regulations. The pump must be connected to an external mains switch. The pump must always be correctly earthed. The pump requires no external motor protection. The motor incorporates thermal protection against slow overloading and blocking (IEC 3-11: TP 11). When the pump is switched on via the mains, the pump will start after approx. 5 seconds. Note: The number of starts and stops via the mains supply must not exceed times per hour. The pump mains connection must be made as shown in the diagrams on the following pages. Cables Use screened cables ( mm ) for external on/off switch, digital input, sensor and setpoint signals. All cables used must be heat-resistant up to at least +5 C. All cables used must be installed in accordance with EN -1. Insulation shells The insulation shells delivered with the single-head MAGNA pumps are for heating applications and should be fitted as part of the installation. Insulation shells For heating For air-conditioning MAGNA Included on delivery See Insulation kits for MAGNA, air-conditioning UPE Accessory Not available Note: Insulation shells are not available for twin-head pumps. 19

20 Installation MAGNA, UPE Wiring diagram External switch ELCB Max. 1 A/1 A TM Fig. 1 1 x 3- V - 1 %/+ %, 5/ z Additional protection If the pump is connected to an electric installation where an earth-leakage circuit breaker (ELCB) is used as an additional protection, the earth-leakage circuit breaker must be marked with the following symbols. The earth-leakage circuit breaker must trip out when earth fault currents with DC content (pulsating DC) occur.

21 Installation MAGNA, UPE MAGNA UPE(D) 1 TM TM TM Fig. UPE(D), terminals inside the control box TM 3 79 Fig. MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1(D), 5-1, mains connection with Alpha power plug Mains connection Signal output Start/stop Potential-free relay input Fig. 3 MAGNA 3-1, -1, 5-1, 5-1, 5-, 5-, mains connection Note: If no external on/off switch is connected, the connection across terminals STOP and should be maintained. TM Pos. Description A, Y, B Terminal block for GENIbus T Terminal block for twin-head pump D 1, (START/STOP) 3, (.) 5, (-1 V) 7, (ALARM) 9, 1, 11 Terminal block for pressure and temperature sensor on the pump (standard) Terminals for external start/stop (connect only contacts with no voltage) Terminals for min. curve input (connect only contacts with no voltage) Terminals for external analog input -1 VDC Terminal 5 = +1 V Terminal = V Terminal block for remote alarm contact. Maximum load: 5 VAC, 5 A. Terminals for supply voltage, 1 x 3 V, 5- z Terminal 9 = Line (L) Terminal 1 = Earth ( ) Terminal 11 = Neutral (N) Terminals for connection of motor cables Terminal 1 = brown lead 1, 13, 1 Terminal 13 = grey lead Terminal 1 = black lead 15 Motor earthing screw 1, 17 Terminals for connection of motor protector, white lead (T1, T) 1 Terminal for control panel 19 Control panel retaining screws Terminal for fan 1 igh-voltage indicator Terminal for screened motor cable 3 Fan Single-head pumps must be connected as shown above. Twin-head pumps Both pump heads must be connected to the mains. 1

22 Installation MAGNA, UPE Examples of connections Connection to external controllers L N NC NO C S T O P Mains connection Operation Alarm Stop Start Dry-running protection TM Fig. 5 Example of MAGNA pump Connection to external controllers L N NC NO C S T O P A Y B X Q Z 1 V GENIbus Alarm Mains connection STOP 1 V Setpoint setting DC -1 V Stop Start Frost protection TM Fig. Example of MAGNA pump with GENI module

23 Curve conditions MAGNA, UPE Curve conditions The guidelines below apply to the performance curves on pages to 53: Test liquid: Airless water at C. All curves show average values and should not be used as guarantee curves. If a stated minimum performance is required, individual measurements must be made. The hatched areas show the pump duty range when the pump is set to controlled operation. Reference supply voltages are: 1 x 3 V, 5 z. Note: Within the MAGNA performance range, the constant- and proportional-pressure curves can be set in steps of 1 m head on the control panel and.1 m head with the R1. 3

24 Technical data MAGNA 5- (N) MAGNA 5- (N) p [kpa] 5 Proportional pressure 5 Constant pressure [hp] Q [m³/h] 3 m m Q [m³/h] 3 m 1 m Q [m³/h] Q [m³/h] Q [l/s] Q [l/s] Electrical data U n [V] P 1 I 1/1 [A] MAGNA 5- is also available with stainless-steel housing, type N. 1 x 3- Min. 1.9 Max. 37. TM TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 5- (N) / 5.3.1

25 Technical data MAGNA 5- (N) MAGNA 5- (N) p [kpa] [hp] Electrical data Q [m³/h] 5 m Proportional pressure m Q [m³/h] Q [l/s] Q [m³/h] 5 m Constant pressure 1 m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- is also available with stainless-steel housing, type N. 1 x 3- Min. 1.9 Max. 5. TM TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 5- (N) /

26 Technical data MAGNA 5- (N) MAGNA 5- (N) p [kpa] 1 Proportional pressure 1 Constant pressure [hp] Electrical data Q [m³/h] 7 m Q [m³/h] Q [l/s] m Q [m³/h] 7 m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- is also available with stainless-steel Min. 1.1 housing, type N. 1 x 3- Max m TM TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 5- (N) / 5.3.1

27 Technical data MAGNA 3- (N) MAGNA 3- (N) p [kpa] 5 Proportional pressure 5 Constant pressure [hp] Q [m³/h] 3 m m Q [m³/h] 3 m 1 m Q [m³/h] Q [m³/h] Q [l/s] Q [l/s] Electrical data U n [V] P 1 I 1/1 [A] MAGNA 3- is also available with stainless-steel housing, type N. 1 x 3- Min. 1.9 Max. 37. TM TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. [m 3 ] L1 B1 B B B B7 1 3 D1 G Gross MAGNA 3- (N)

28 Technical data MAGNA 3- (N) MAGNA 3- (N) p [kpa] [hp] Electrical data Q [m³/h] 5 m Proportional pressure Q [m³/h] Q [l/s] m Q [m³/h] Constant pressure 5 m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3- is also available with stainless-steel housing, type N. 1 x 3- Min. 1.9 Max m TM TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 3- (N)

29 Technical data MAGNA 3- (N) MAGNA 3- (N) p [kpa] 1 Proportional pressure 1 Constant pressure [hp] Electrical data Q [m³/h] 7 m Q [m³/h] Q [l/s] m Q [m³/h] 7 m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3- is also available with stainless-steel Min housing, type N. 1 x 3- Max m TM TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. [m 3 ] L1 B1 B B B B7 1 3 D1 G Gross MAGNA 3- (N)

30 Technical data MAGNA 3- F MAGNA 3- F p [kpa] 1 Proportional pressure 1 Constant pressure [hp] Electrical data Q [m³/h] Q [m³/h] 7 m Q [l/s] m Q [m³/h] 7 m Q [m³/h] Q [l/s] 1 m TM U n [V] P 1 I 1/1 [A] Min x 3- Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA 3- F / /1..1 3

31 Technical data MAGNA 5-1 (N) MAGNA 5-1 (N) p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 9 m m Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5-1 is also available with stainless-steel Min. 1.9 housing, type N. 1 x 3- Max TM TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 5-1 (N) /

32 Technical data MAGNA 3-1 (N) MAGNA 3-1 (N) p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 9 m m 1 Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3-1 is also available with stainless-steel Min. 1.1 housing, type N. 1 x 3- Max m TM TM Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 G Gross [m 3 ] MAGNA 3-1 (N) (N).1 3

33 Technical data MAGNA 3-1 F (N) MAGNA 3-1 F (N) p [kpa] Proportional pressure 1 1 Constant pressure Electrical data U n [V] P 1 I 1/1 [A] MAGNA 3-1 is also available with stainless-steel Min. 1.1 housing, type N. 1 x 3- [hp] Q [m³/h] m m 1 Q [m³/h] Q [l/s] Max Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] 1 m TM TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA 3-1 F (N) / /

34 Technical data MAGNA - F MAGNA - F p [kpa] [hp] Q [m³/h] 5 m Proportional pressure m Q [m³/h] 5 m Constant pressure 1 m Q [m³/h] Q [l/s] Electrical data Q [m³/h] Q [l/s] TM U n [V] P 1 I 1/1 [A] Min x 3- Max. 9.7 TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA - F / /

35 Technical data MAGNA - F MAGNA - F p [kpa] 1 Proportional pressure 1 Constant pressure [hp] Electrical data Q [m³/h] 7 m Q [m³/h] Q [l/s] m Q [m³/h] 7 m Q [m³/h] Q [l/s] 1 m TM U n [V] P 1 I 1/1 [A] Min x 3- Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA - F / /

36 Technical data MAGNA -1 F MAGNA -1 F p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data Q [m³/h] 9 m m Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 m Q [m³/h] Q [l/s] TM U n [V] P 1 I 1/1 [A] Min x 3- Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA -1 F / /

37 Technical data MAGNA 5-1 F MAGNA 5-1 F p [kpa] Proportional pressure 1 1 Constant pressure [hp] Electrical data 1 Q [m³/h] 9 m m 1 Q [m³/h] Q [l/s] Q [m³/h] 9 m 1 Q [m³/h] Q [l/s] 1 m TM U n [V] P 1 I 1/1 [A] Min x 3- Max TM Dimensions and weights Dimensions [mm] Weight [kg] Ship. vol. L1 B1 B B B B7 1 3 D1 D D3 D D5 PN Gross [m 3 ] MAGNA 5-1 F / /

38 Technical data MAGNA 3-1 F (N) MAGNA 3-1 F (N) p [kpa] 1 1 [hp] Electrical data Q [m³/h] 1 m m Proportional pressure m m Q [m³/h] Q [l/s] Q [m³/h] 1 m m Constant pressure m m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 3-1 F is also available with stainless-steel Min housing, type N. 1 x 3- Max TM 191 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA 3-1 F (N) /1 1 1/19 M

39 Technical data MAGNA -1 F (N) MAGNA -1 F (N) p [kpa] 1 1 [hp] Electrical data Q [m³/h] 1 m m m Proportional pressure m Q [m³/h] Q [l/s] Q [m³/h] 1 m Constant pressure m m m Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA -1 F is also available with stainless-steel Min housing, type N. 1 x 3- Max. 5. TM 1911 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA -1 F (N) / /19 M

40 Technical data MAGNA 5- F (N) MAGNA 5- F (N) p [kpa] [hp] Electrical data 1 1 Q [m³/h] Proportional pressure 5 m m 1 1 Q [m³/h] Q [l/s] 3 m m Q [m³/h] Constant pressure 5 m m 3 m m 1 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5- F is also available with stainless-steel Min housing, type N. 1 x 3- Max. 1.7 TM 191 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA 5- F (N) / /19 M

41 Technical data MAGNA 5- F (N) MAGNA 5- F (N) p [kpa] [hp] Electrical data 1 1 Q [m³/h] Proportional pressure 5 m m 3 m 1 1 Q [m³/h] m Q [m³/h] Constant pressure 5 m m 3 m m 1 1 Q [m³/h] U n [V] P 1 I 1/1 [A] MAGNA 5- F is also available with stainless-steel Min housing, type N. 1 x 3- Max. 5. TM 1913 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA 5- F (N) / /19 M1.3 1

42 Technical data MAGNA 5-1 F (N) MAGNA 5-1 F (N) p [kpa] 1 1 [hp] Q [m³/h] Electrical data 1 m Proportional pressure m m m 1 1 Q [m³/h] Q [l/s] Q [m³/h] Constant pressure 1 m m m m 1 1 Q [m³/h] Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5-1 F is also available with stainless-steel Min. 35. housing, type N. 1 x 3- Max. 3.5 TM 1 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA 5-1 F (N) / /19 M1.3

43 Technical data MAGNA 5-1 F (N) MAGNA 5-1 F (N) p [kpa] 1 1 [hp] Q [m³/h] Electrical data 1 m m Proportional pressure Q [m³/h] 1 Q [l/s] m m Q [m³/h] 1 m Constant pressure m m Q [m³/h] 1 Q [l/s] U n [V] P 1 I 1/1 [A] MAGNA 5-1 F is also available with stainless-steel Min. 35. housing, type N. 1 x 3- Max m TM 15 B 1 3 B5 D D D1 B1 L1 D5 M L3 Rp 1/ B B B3 B7 D3 D3 TM 39 3 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA 5-1 F (N) / /19 M

44 Technical data UPE -1 FZ UPE -1 FZ p [kpa] 1 1 [hp] Proportional pressure Q [m³/h].5m.5m Q [m³/h] 11 m Constant pressure 1 m Q [m³/h] 1 1 Q [l/s] Q [m³/h] 1 1 Q [l/s] TM Electrical data U n [V] P 1 I 1/1 [A] Min.. 1 x 3 Max TM Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B B5 B7 B B9 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPE -1 FZ (PN ) / 1 M UPE -1 FZ (PN 1) M

45 Technical data UPE 1-1 FZ UPE 1-1 FZ p [kpa] 1 1 [hp] Proportional pressure Q [m³/h].5m.5m Q [m³/h] 11 m Constant pressure 1 m Q [m³/h] 1 1 Q [l/s] Q [m³/h] 1 1 Q [l/s] TM Electrical data U n [V] P 1 I 1/1 [A] 1 x 3 Min.. Max TM Dimensions and weights Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B1 B B B5 B7 B B9 1 3 D1 D D3 D D5 M Net Gross [m 3 ] UPE 1-1 FZ (PN ) M UPE 1-1 FZ (PN 1) M

46 Technical data MAGNA D -1 F MAGNA D -1 F p [kpa] Proportional pressure 1 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m m m Q [m³/h] m Q [m³/h] TM Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 1.9 pump head. 1 x 3- Max TM Dimensions and weights PN / PN 1 Dimensions [mm] Weight [kg] Ship. vol. [m 3 ] L1 B1 B B3 B B5 1 3 D1 D D3 D D5 PN Gross MAGNA D -1 F / /

47 Technical data MAGNA D 3-1 F MAGNA D 3-1 F p [kpa] Proportional pressure Constant pressure Q [m³/h] Q [m³/h] [hp] m m m m Q [m³/h] Q [l/s] m m m m Q [m³/h] Q [l/s] TM 191 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- Max B1 B3 1 3 B B7 B D D D1 D5 Rp1/ L L3 B B5 M L1 D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 3-1 F /1 1 1/19 M

48 Technical data MAGNA D -1 F MAGNA D -1 F p [kpa] Proportional pressure Constant pressure Q [m³/h] Q [m³/h] [hp] m m m m Q [m³/h] Q [l/s] m m m m Q [m³/h] Q [l/s] TM 1911 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- Max. 5. B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D -1 F / /19 M1 5.57

49 Technical data MAGNA D 5- F MAGNA D 5- F p [kpa] Proportional pressure 7 5 Constant pressure Q [m³/h] Q [m³/h] [hp] m m 1 1 Q [m³/h] Q [l/s] 3 m m m m 3 m m 1 1 Q [m³/h] Q [l/s] TM 191 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- Max. 1.7 B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5- F / /19 M

50 Technical data MAGNA D 5- F MAGNA D 5- F p [kpa] Proportional pressure 7 5 Constant pressure Q [m³/h] Q [m³/h] [hp] m m 3 m 1 1 Q [m³/h] Q [l/s] m m m 3 m m 1 1 Q [m³/h] Q [l/s] TM 1913 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min pump head. 1 x 3- Max. 5. B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5- F / /19 M

51 Technical data MAGNA D 5-1 F MAGNA D 5-1 F p [kpa] Proportional pressure Constant pressure 1 1 Q [m³/h] 1 1 Q [m³/h] [hp] m m m m 1 1 Q [m³/h] Q [l/s] 1 1 m m m m 1 1 Q [m³/h] Q [l/s] TM 1 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 35. pump head. 1 x 3- Max. 3.5 B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross MAGNA D 5-1 F / /19 M

52 Technical data MAGNA D 5-1 F MAGNA D 5-1 F p [kpa] Proportional pressure Constant pressure Q [m³/h] Q [m³/h] [hp] m m Q [m³/h] 1 Q [l/s] m m 1 1 m m m Q [m³/h] 1 Q [l/s] m TM 15 Electrical data U n [V] P 1 I 1/1 [A] Curves and electrical data apply to one operating Min. 35. pump head. 1 x 3- Max B1 B3 1 3 B B7 B D D D1 L L1 D5 Rp1/ L3 B B5 M D3 D3 TM 79 1 Dimensions and weights PN / PN 1 Dimensions [mm] Weights [kg] Ship. vol. L1 L L3 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross [m 3 ] MAGNA D 5-1 F / /19 M

53 Technical data UPED -1 FZ UPED -1 FZ p [kpa] 1 Proportional pressure 1 Constant pressure Q [m³/h] Q [m³/h] [hp] m 3 m Q [m³/h] 1 1 Q [l/s] m m Q [m³/h] 1 1 Q [l/s] TM 19 1 Electrical data U n [V] P 1 I 1/1 [A] Electrical data apply to one operating pump head. 1 x 3 Min.. Max TM Dimensions and weights UPED -1 FZ (PN ) UPED -1 FZ (PN 1) Dimensions [mm] Weights [kg] Ship. vol. [m 3 ] L1 L L3 B1 B B3 B B5 B B7 1 3 D1 D D3 D D5 M Net Gross M M

54 Accessories MAGNA, UPE Base plates Base plates including hexagon screws are available on request. MAGNA 5- F, 5- F MAGNA 3-1 F, 5-1 F MAGNA -1 F, 5-1 F MAGNA 3-1 FN, -1 FN MAGNA 5- FN, 5- FN MAGNA 5-1 FN, 5-1 FN exagon screws Product number x M1 x mm 9535 x M1 x mm 531 Blanking flanges MAGNA D 3-1 F MAGNA D -1 F MAGNA D 5- F MAGNA D 5-1 F MAGNA D 5- F MAGNA D 5-1 F Union and valve kits Union kits Product number Fig. 7 Base plate for MAGNA Adapter xø1 xø1 1 xø1 The adapter is to be used when you replace pumps with different port-to-port lengths. 35 TM Pressure stage Size MAGNA 5 PN 1 MAGNA 3 PN 1 Valve kits Pressure stage Size Material: Steel, S35JR (EN 15). TM3 35 Product number Rp 3/ 5991 Rp Rp 1 1/ 597 Rp Rp 1 1/ 599 Product number Rp 3/ 5195 MAGNA 5 PN 1 Rp Rp 1 1/ 5197 MAGNA 3 PN 1 Rp 1 1/ Pressure DN Thickness Inner diameter Outer diameter Product number PN PN PN PN

55 Accessories MAGNA, UPE Counter flanges The flange kit comprises: flanges with internal thread (ISO sealing pipe thread) or flanges for welding/soldering gaskets bolts. Rp: mm: Counter flanges for cast-iron pump housing Pressure stage Size MAGNA (D) 3 PN 1 MAGNA (D) PN 1 MAGNA (D) 5 PN 1 MAGNA (D) 5 PN 1 UPE(D) FZ PN PN 1 Flange with internal thread (ISO sealing pipe thread). Flange for welding/soldering. Counter flanges according to ISO Product number Rp 1 1/ mm 5397 Rp 1 1/ mm 5397 Rp mm 59 Rp 1/ mm 559 Rp mm 5991 Rp 3 59 mm 591 Rp PN 1 mm 5799 UPE 1 FZ Rp 5791 PN 1 1 mm 579 Counter flanges for bronze or stainless-steel pump housing MAGNA 3 (N) PN 1 MAGNA (N) PN 1 MAGNA 5 (N) PN 1 MAGNA 5 (N) PN 1 Rp 1 1/ mm 973 Rp 1 1/ mm Rp mm 591 Rp 1/ mm

56 Accessories MAGNA, UPE Insulation kits for UPE, heating Single-head UPE pumps can be fitted with insulation shells for heating applications. A kit consists of two shells. Product number UPE -1 FZ, PN /PN UPE 1-1 FZ, PN /PN Insulation kits for MAGNA, air-conditioning Single-head MAGNA pumps can be fitted with insulation shells for air-conditioning applications. A kit consists of two shells made of polyurethane (PUR) and a self-adhesive seal to ensure tight assembly. Insulation kits for MAGNA, heating Insulation shells for heating applications for single-head MAGNA pumps are included from factory. A kit consists of two shells. Fig. Fitting the insulation shells to a MAGNA pump TM TM 5 7 Fig. 9 Fitting the insulation shells to a MAGNA pump Note: The dimensions of the insulation shells for air-conditioning applications are different from the dimensions of the insulation shells for heating applications. See the dimensions below. TM TM 5 7 Product number MAGNA 5-, 5-, 5-, 5-1, 3-, 3-, 3-, 3-1, 3-1 F, - F, F, -1 F MAGNA 5-1 F 9751 MAGNA 3-1 F MAGNA -1 F MAGNA 5- F, 5-1 F 9751 MAGNA 5- F, 5-1 F Fig. 3 Dimensional sketch, insulation shells TM Dimensions L B Product number MAGNA 5-, 5-, 5-1, 3-, 3-, MAGNA 3-1 F, - F, - F, F MAGNA 5-1 F MAGNA 3-1 F MAGNA -1 F MAGNA 5- F, 5-1 F MAGNA 5- F, 5-1 F

57 Accessories MAGNA, UPE Expansion modules for MAGNA 5-5-, 5-, 5-1, 3-, 3-, 3-, 3-1, -, -, -1 (D), 5-1 MAGNA pumps can be fitted with an expansion module enabling communication via external signals (signal transmitters). Two types of expansion module are available: GENI module Relay module. Product Product number GENI module Relay module 9333 GENI module The GENI module offers the following functions: External start/stop The GENI module incorporates a digital input for an external contact. The pump can be started and stopped via this input. When started, the pump will operate with the setpoint set on the control panel or with the R1. External forced control The GENI module incorporates inputs for external signals for the forced-control functions: Max. curve duty Min. curve duty. External analog -1 V control The GENI module has an input for an external -1 VDC analog signal transmitter. Via this input, the pump can be controlled by an external controller if the pump has been set to one of the following control modes: Constant curve The external analog signal will control the pump curve within the range from the min. curve to the constant curve selected according to the characteristic. Proportional- or constant-pressure control The external analog signal will control the setpoint for the pump head between the setpoint corresponding to the min. curve and the setpoint selected according to the characteristic. Fault, ready and operating indication via signal relay The function of the signal relay can be set with the R1. Possible functions: Fault Ready Operation. Fault indication The signal relay is activated in case of Pump blocked Internal fault Undervoltage. Ready indication The signal relay is active when the pump is in operation or ready for operation. Operating indication The signal relay is active as long as the pump is operating. If the pump is stopped on the control panel, with the R1 or because of a fault, the signal relay is deactivated and consequently gives a signal to an external control system, e.g. a building management system. Control of twin-head pumps When fitted with two GENI modules, a twin-head pump functions fully automatically. A GENI module must be mounted on the control box of each pump head and the modules must be connected using a cable. Both pump heads must be connected to the electricity supply. Bus communication via GENIbus The GENI module enables serial communication via a RS-5 input. The communication is carried out according to the Grundfos bus protocol, GENIbus, and enables connection to the Control MPC Series, a building management system or another type of external control system. Via the bus signal, it is possible to set pump operating parameters, such as desired setpoint, temperature influence, operating mode, etc. 57

58 Accessories MAGNA, UPE At the same time, the pump can provide status information about important parameters, such as actual head, actual flow, power input, fault indications, etc. Fault, ready and operating indication via signal relay The function of the signal relay can be set with the R1. Inputs for max. and min. curves and start/stop Input for analog -1 V signal Input for control of twinhead pumps Bus input Output for signal relay External potential-free contact. Contact load: 5 V, 1 ma. Screened cable. Loop resistance: Maximum 13 Ω. External signal: -1 VDC. Maximum load: 1 ma. Screened cable. Screened cable. Wire cross-section:.5-1 mm. Cable length: Maximum 1 m. Grundfos GENIbus protocol, RS-5. Screened cable. Wire cross-section:.5-1 mm. Cable length: Maximum 1 m. Potential-free changeover contact. VAC, A AC1. 3 VDC, A. Possible functions: Fault Ready Operation. Fault indication The signal relay is activated in case of Pump blocked Internal fault Undervoltage. Ready indication The signal relay is active when the pump is in operation or ready for operation. Operating indication The signal relay is active as long as the pump is operating. If the pump is stopped on the control panel, with the R1 or because of a fault, the signal relay is deactivated and consequently gives a signal to an external control system, e.g. a building management system. Input for start/stop Output for signal relay External potential-free contact. Contact load: 5 V, 1 ma. Screened cable. Loop resistance: Maximum 13 Ω. Potential-free changeover contact. VAC, A AC1. 3 VDC, A. TM Fig. 31 Connection of GENI module Relay module The relay module offers the following functions: External start/stop The relay module incorporates a digital input for an external contact. The pump can be started and stopped via this input. When started, the pump will operate with the setpoint set on the control panel or with the R1. TM Fig. 3 Connection of relay module 5

59 Accessories MAGNA, UPE Expansion modules for MAGNA (D) 5-, 5-, 3-1, -1, 5-1, 5-1 MAGNA pumps can be fitted with an expansion module enabling communication via external signals (signal transmitters). Two types of expansion module are available: GENI module LON module. The expansion module is fitted by opening the control box cover and placing the module inside the control box. Product Product number GENI module 595 LON module 59 GENI module The GENI module has an input for an external -1 VDC analog signal transmitter (terminal 1 V and ). Via this input, the pump can be controlled by an external controller if the pump has been set to one of the following control modes: Constant curve Proportional- or constant-pressure control. The GENI module also incorporates inputs for external signals for the forced-control functions: Max. curve duty Min. curve duty. Input signals Setpoint signals Bus input Max. and min. curve input External potential-free switch. Maximum contact load: 5 V, 1 ma. Screened cable. Maximum loop resistance: 13 Ω. Input for analog -1 V signal External signal: -1 VDC. Maximum load:.1 ma. Screened cable. Grundfos GENIbus protocol, RS-5. Screened cable. Wire cross-section:.5-1 mm. Maximum cable length: 1 m. Fig. 33 Connection of GENI module LON module The LON module offers the possibility of connecting the pump to a LonWorks network. The module is used for data transmission between a network and the MAGNA pump. Input signals Bus input 1 V A Y B X Q Z LonTalk protocol, FTT 1. Non-screened, twisted-pair cable. Wire cross-section:.5-1 mm. TM 3 17 A B TM 37 9 Fig. 3 Connection of LON module 59

60 Accessories MAGNA, UPE R1 The R1 is designed for wireless communication with the pump. The R1 communicates with the pump via infra-red light. Communication Interface Units (CIU) Product Product number R Control MPC Series Control MPC Series is a pump controller designed for the control and monitoring of up to six MAGNA/UPE Series pumps. All pumps must be of the same pump type and size. Control MPC Series is used for controlling circulator pumps in heating and air-conditioning applications. Control MPC Series ensures optimum adaptation of the performance to the demand by closed-loop control of proportional differential pressure, constant differential pressure. By means of an external sensor Control MPC Series can also ensure optimum adaptation of the performance to the demand by closed-loop control of differential pressure (remote) flow temperature temperature difference. Product Number of MAGNA/ UPE pumps Product number Control MPC Series * * An external GENIbus module, product number 9339, and a suitable gateway must be added if used in a BMS system. Fig. 35 Grundfos CIU unit The CIU units enable communication of operating data, such as measured values and setpoints, between pumps and a building management system. The CIU unit incorporates a - VAC/VDC power supply module and a CIM module (Communication Interface Module). It can either be mounted on a DIN rail or on a wall. We offer the following CIU units: CIU 1 For communication via LON. CIU 15 For communication via Profibus. CIU For communication via Modbus RTU. CIU 5 For wireless communication via SMS/GSM/GPRS. CIU 3 For communication via BACnet MS/TP. Description Fieldbus protocol Product number CIU 1 LON CIU 15 Profibus CIU Modbus RTU 9753 CIU 5 GSM/GPRS 9771 CIU 3 BACnet MS/TP For further information about data communication via CIU units and fieldbus protocols, see the CIU documentation available in WebCAPS. GrA 11

61 Order data MAGNA, UPE MAGNA/UPE, cast iron Product number Pipe connection Flange connection 1" 1 1/ " PN /PN 1 PN PN 1 Single-head pumps MAGNA MAGNA MAGNA MAGNA MAGNA MAGNA MAGNA 3- F MAGNA - F MAGNA - F MAGNA 5- F MAGNA 5- F MAGNA MAGNA MAGNA 3-1 F MAGNA -1 F MAGNA 5-1 F MAGNA 3-1 F MAGNA -1 F MAGNA 5-1 F MAGNA 5-1 F UPE -1 FZ UPE 1-1 FZ Twin-head pumps MAGNA D 5- F MAGNA D 5- F MAGNA D -1 F MAGNA D 3-1 F MAGNA D -1 F MAGNA D 5-1 F MAGNA D 5-1 F UPED -1 FZ MAGNA, stainless steel Product number Pipe connection Flange connection G 1 1/ G PN /PN 1 MAGNA 5- N MAGNA 3- N MAGNA 5- N MAGNA 3- N MAGNA 5- N MAGNA 3- N MAGNA 5-1 N MAGNA 3-1 N MAGNA 3-1 FN MAGNA -1 FN MAGNA 5- FN MAGNA 5- FN MAGNA 5-1 FN MAGNA 5-1 FN

62 ... Further product documentation MAGNA, UPE WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 15, Grundfos products in more than languages. In WebCAPS, all information is divided into six sections: Catalogue Literature Service Sizing Replacement CAD drawings. Catalogue This section is based on fields of application and pump types, and contains technical data curves (Q, Eta,, P, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures. Service This section contains an easy-to-use interactive service catalogue. ere you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.

63 ... 1 Further product documentation MAGNA, UPE Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download -dimensional (D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: -dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 15, Grundfos products in more than languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 3 WinCAPS CD-ROM Subject to alterations. 3

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids Type key 5 Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET Series circulator pumps Contents Product data MAGNA and UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key Contents dentification Type key Product data ntroduction Applications Features and benefits Performance range pole pole pole Construction Sectional drawing Construction features Test pressure Operating

More information

CMA - B - C - D - CMR

CMA - B - C - D - CMR Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

GRUNDFOS DATA BOOKLET. Series 200. UPS and UPSD circulator pumps 50 Hz

GRUNDFOS DATA BOOKLET. Series 200. UPS and UPSD circulator pumps 50 Hz GRUNDFOS DATA BOOKLET Series UPS and UPSD circulator ums 5 z Contents General data Performance range Product range Single-head ums Twin-head ums 5 Tye key 5 5 Alications 6 eating systems 6 Domestic hot

More information

SVH with HYDROVAR (HVL range)

SVH with HYDROVAR (HVL range) SVH with HYDROVAR (HVL range) SVH-HVL Rev. B Ed.9/1 (EN) SVH SERIES (e-sv WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications,

More information

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz

GRUNDFOS PRODUCT GUIDE. VersaFlo UP, UPS. Series 200 circulator pumps 60 Hz GRUNDFOS PRODUCT GUIDE VersaFlo UP, UPS Series circulator pumps Hz Contents ission General data Terminal box modules Applications Pumped liquids Type key 5 Nameplate 5 Performance range UPS pumps UP pumps

More information

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron Cast iron self-priming electric pumps. APPLICATIONS Pressure boosting domestic plants Small-scale irrigation Moving non-aggressive liquids for civil and industrial use Washing plants Washing vehicles CMA-B-C-D

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz RANGE OF USE Flow rate: from 0 to 0 m/h Manometric head: up to mce Temperature of the fluid: from 0 to + C Ambient temperature: -0 to +0 C Max. operating pressure: bars (version SIE) bars (version LRE)

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

VK2 volume flow controller Overview

VK2 volume flow controller Overview New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

LES. Single-stage end-suction pumps Identification Type key

LES. Single-stage end-suction pumps Identification Type key Contents Singlestage endsuction pumps Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole 6 pole Construction Sectional drawing Construction

More information

Circulation pumps CATALOGUE. Wet rotor circulators and accessories. Heating, air-conditioning, solar, domestic water

Circulation pumps CATALOGUE. Wet rotor circulators and accessories. Heating, air-conditioning, solar, domestic water Circulation pumps Wet rotor circulators and accessories CATALOGUE eating, air-conditioning, solar, domestic water alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series PiB Series PiB (Pump-in-a-Box) & 9 Series FILE NO: - DATE: July SUPERSEDES: - DATE: January 09 PiB Series Guaranteed In Stock At The Right Price! The PiB series builds on the high quality and unsurpassed

More information

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS Variable or constant flow regulation or constant pressure regulation Wireless communication via radio Integrated sensor

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Multifunctional Thermostatic Circulation Valve MTCV

Multifunctional Thermostatic Circulation Valve MTCV Multifunctional Thermostatic Circulation Valve MTCV Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory Fig. 3 Version

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05 Modulating digital controller for heating and cooling series REGI ERED SI EN ISO 00:000 Cert. n FM UNI EN ISO 00:000 Cert. n 000 0/0 G replaces dp 0/0 Function The controller can be used with three-point

More information

VD1 CLC. Small Valves DIN-range with a higher k v -value

VD1 CLC. Small Valves DIN-range with a higher k v -value 0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob /

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H Type Series Booklet.5/7-0 G CPK-H Standardized Chemical Pumps to EN 5/ISO 5/ISO 599, heatable Automation products available: Hya-Drive Hyamaster hyatronic Fields of Application CPK-H pumps are used for

More information

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181 Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULATORS TECNICAL DATA EVOTRON WET ROTOR ELECTRONIC CIRCULATORS Operating range: from, -, m/h with head of up to metres. Pumped liquid temperature range: from -1 C to +11 C. Working

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -A - Introduction - Thank for your purchasing MITSUBISHI ELECTRIC MELPRO TM D Series Digital Protection

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m

50 Hz n= 2900 rpm. Standardised EN 733 centrifugal pumps INSTALLATION AND USE. PERFORMANCE RANGE Flow rate up to 6000 l/min (360 m³/h) Head up to 98 m F Standardised EN 733 centrifugal pumps Hz n= 9 rpm Clean water Industrial use PERFORMNCE RNGE Flow rate up to (3 ) Head up to 9 m PPLICTION LIMITS Manometric suction lift up to 7 m Liquid temperature

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

PAA-ANALYZERS PRINCIPLE OF OPERATION

PAA-ANALYZERS PRINCIPLE OF OPERATION PAA-ANALYZERS PRINCIPLE OF OPERATION The PAA process analyzer comprises a control unit and an analyzing section which includes the reaction chamber and measuring cell, reagent pumps and associated valves

More information

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP I N V E RT E R ion Range exible Combine Modular TDV I TDV I TDV I INVERTER INVERTER INVERTER 14, 16, 18, 20, 22 HP TDV I 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP INVERTER INVERTER INVERTER TDV I INVERTER

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to

More information

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke. Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

Pressure independent balancing and control valve AB QM DN

Pressure independent balancing and control valve AB QM DN Data sheet Pressure independent balancing and control valve AB QM DN 10-250 The AB QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports

NM, NMD 60 Hz NM, NMD. Close Coupled Centrifugal Pumps with threaded ports , D z Close Coupled Centrifugal ups Construction Close-coupled, centrifugal pups; electric otor with extended sha directly connected to the pup. : single-ipeller D: with two back-to-back ipellers (with

More information

Technical specification FLUXUS F502TE

Technical specification FLUXUS F502TE Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring

More information

ELECTRONIC WET ROTOR CIRCULATORS

ELECTRONIC WET ROTOR CIRCULATORS ELECTRONIC WET ROTOR CIRCULTORS Technical Sheet ELECTRONIC CIRCULTORS FOR ETING ND IR CONDITIONING SYSTEMS Energ ia e y GENERL DT compliant with the 3 and european directive ErP 9//EC (ex EuP) pplications

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

ISEmax CAM40/CAS40. Technical Information

ISEmax CAM40/CAS40. Technical Information Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works

More information

HiPace 1200, with TC 1200, DN 200 CF-F

HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F HiPace 1200, with TC 1200, DN 200 CF-F Similar Image Powerful turbopump with a pumping speed of up to 1250 l/s for N 2 DN 200 CF-F flange for demanding UHV applications

More information

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming

Prima range. Alifter range. magnetical driven pumps in thermoplastic materials TMP TMA. centrifugal. self-priming Prima range TMP centrifugal Alifter range magnetical driven pumps in thermoplastic materials TMA self-priming Prima - Alifter In this catalog Argal proposes the range of PRIMA pumps, magnetical driven,

More information

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits 200 > Measurement and instrumentation Programmable digital transducers TRIAD 2 range Programmable digital transducers with to 4 analogue outputs Programmable accuracy class PRODUCT ADVANTAGES Up to 4 PROGRAMMABLE

More information

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16 LK4 DESCRIPTION Dutair LK-series industrial ventilators consist of a robust body made from die-cast aluminium alloy. Impellers are made of extruded aluminium. The asynchronous electric motors are maintenance

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS. ErP. eady ELECTRONIC CIRCULATORS OR EATING AND COOLING SYSTEMS ErP eady TECNICAL DATA EVOSTA 2 WET ROTOR ELECTRONIC CIRCULATORS Operating range:,-3,6 m 3 /h with head up to 6,9 metres. Pumped liquid temperature

More information

HiPace 300 with TC 110, DN 100 CF-F

HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F HiPace 300 with TC 110, DN 100 CF-F Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 110 drive electronics Ideal for UHV applications

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such

More information

HiPace 300 with TC 400, DN 100 CF-F

HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F HiPace 300 with TC 400, DN 100 CF-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N 2 Integrated TC 400 drive electronics Ideal

More information

TETRIS W FC NG kw

TETRIS W FC NG kw 40 640 kw General description TETRIS W FC/NG is a free cooling chiller for indoor installation that integrates uncoupling exchanger, 3-way modulating valve, inverter-controlled pump on the source side

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

Pressure independent balancing and control valve AB QM DN

Pressure independent balancing and control valve AB QM DN Data sheet Pressure independent balancing and control valve AB QM DN 10-250 The AB QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.

More information

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1. Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark.

More information

473-SHX Dew Point Mirror

473-SHX Dew Point Mirror Humidity and Temperature Reference Hygrometer For Temperature up to 125 C Precise and stable chilled mirror dew point mirror technology High temperature optical components High temperature sample fan Cable

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

variable flow dampers

variable flow dampers Constant-/ DAU, DAEU, DAVU Summary DAU - manual single flow unit DAEU - motorized twin flow unit DAVU - motorized variable flow unit Diameters Ø 0 Flow range 0 l/s ( m³/h) Pressure range Pa (over the unit)

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Introduction to Blackbody Sources

Introduction to Blackbody Sources Introduction to s This section contains dedicated blackbody sources for low uncertainty calibration of infrared thermometers. A range of portable primary blackbody sources combine high emissivity with

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

PFI Closed circuit cooling towers

PFI Closed circuit cooling towers PFI Closed circuit cooling towers Key benefits Lowest energy consumption and total cost of ownership Year round reliable operation Ideal replacement unit with certified thermal performance PFI characteristics

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Precision Ball Screw/Spline

Precision Ball Screw/Spline 58-2E Models BNS-A, BNS, NS-A and NS Seal Outer ring Shim plate Seal Spline nut Seal Collar Shim plate Seal End cap Ball Outer ring Ball screw nut Outer ring Ball Retainer Retainer Outer ring Point of

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications Technical Description Hydraulic Excavator A 95 C HD litronic` Machine for Industrial Applications Operating Weight 165,800 170,0 lb Engine Output 36 hp (0 kw) Technical Data Engine Rating per ISO 99 0

More information

System Components. Electric Motors.

System Components. Electric Motors. System Components Electric Motors www.powerjacks.com Contents.1. Electric Motors.1.1. AC Motors.1.. AC Motor Performance 0 rpm ( pole).1.. AC Motor Performance 00 rpm ( pole).1.. AC Motors with Integral

More information