ACE. Intelligent Solutions for Method Development. Method Development Kits ACE

Size: px
Start display at page:

Download "ACE. Intelligent Solutions for Method Development. Method Development Kits ACE"

Transcription

1 r: ffe e its ric k ty mn e p i tiv olu sam mn c c u le the col e d S an for ngle le si ab s a l i a a av O ACE Method Development Kits Intelligent Solutions for Method Development UHPLC and HPLC method development kits Kits available from microbore to analytical dimensions Porous, solid-core and biomolecule options Wide range of particle sizes and complementary phases available Excellent peak shape, efficiency, reproducibility and lifetime Highly cost effective ACE UHPLC and HPLC Columns

2 ACE Method Development Kits Intelligent Solutions for Method Development Highly cost effective - ACE Method Development Kits are available for the same price as a single column! different ACE Method Development Kits available from microbore (0.mm id) through to analytical (.mm id) dimensions for rapid, systematic method development. Each kit contains carefully selected ACE phases which enables the power of selectivity to be fully exploited. Each ACE phase provides different selectivity due to differing interactions. ACE Advanced Method Development Kit (see pages -) ACE Extended Method Development Kit (see pages -) Bonded Phase Hydrophobic Binding Separation Mechanism and Relative Strength π-π Interaction Dipole- Dipole Hydrogen Bonding Shape Selectivity ACE C **** - - * ** ACE C-AR **** *** (donor) * ** *** ACE C-PFP **** *** (acceptor) **** *** **** ACE SuperC **** ** ACE C-Amide **** - ** **** **/*** ACE CN-ES *** * *** ** * ACE UltraCore Method Development Kit (see pages -) ACE UltraCore SuperC ACE UltraCore SuperPhenylHexyl *** ** ** *** (donor) * ** *** ACE Bioanalytical 00Å Method Development Kit (see pages -) ACE C-00 ** - - * * ACE C-00 * ACE Phenyl-00 * ** (donor) * ** ** Approximate value determined by semi-quantitative mechanism weightings and/or by reference to other ACE phases using >00 characterising analytes. FREE Method Development Support! Not sure which ACE phase or kit will work best for your application? FREE Application Support and FREE Method Development Service Trust your method development to our experts and free up time for your other projects! Contact our expert method development team via info@ace-hplc.com or contact your local distributor Learn More: Columns

3 Selectivity Offer: and column kits available for the same price as a single column Why Use ACE Method Development Kits? ACE HPLC/UHPLC columns have earned a well deserved reputation for delivering excellent efficiency, reproducibility and lifetime. ACE Method Development Kits group together columns with different mechanisms of interaction to maximise selectivity and improve the likelihood of separating difficult or closely related analytes in mixtures. Screening columns containing different bonded phases under the same mobile phase conditions can help you achieve your desired separation more quickly, therefore increasing productivity. Highly cost effective to promote bonded phase investigation as part of an intelligent method development strategy, ACE Method Development Kits are available for the same price as a single column! Si-OH ACE Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC & HPLC Separations Using ACE Method Development Kits to Improve Separations Columns Within ACE Method Development Kits Provide Alternative Selectivity Application #0 0, ACE C,, ACE C provides excellent peak shape, but here the essentially hydrophobic-only interaction results in co-elution. Investigation of alternative bonded phases using the same test conditions is recommended. 0 Time - 0 ACE C-PFP ACE C-PFP provides additional interactions compared to alkyl C phases. Whilst these change selectivity, in this instance co-elution of different analyte pairs is observed. 0 Time - ACE C-AR 0 The ACE C-AR phase provides a further change in selectivity due to different interaction contributions ultimately enabling a successful separation. Screening alternative phases can maximise selectivity and reduce method development time. 0 Time - Sample: ) metronidazole ) -hydroxybenzoic acid ) -hydroxybenzoic acid ) benzyl alcohol ) benzoic acid ) myrecetin ) p-cresol ) propranolol ) ethyl paraben 0) furosemide ) anisole ),,-trinitrobenzene ) toluene ) nimesulide ) mefenamic acid ),,-trichlorobenzene Mobile Phase: A = 0.% formic acid in H O B = 0.% formic acid in MeCN Gradient: 00% B in minutes Column Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Detection: 0nm

4 ACE Advanced Method Development Kit Contains ACE C, ACE C-AR and ACE C-PFP phases Ideal starting point for routine method development Available from microbore (0. mm id) through to analytical (. mm id) dimensions (see p.) Particularly recommended for compounds containing aromatic rings Phase Functional Group Endcapped Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Recommended ph Range 00% Aqueous Compatible USP Listing ACE C Octadecyl (C) Yes. NEW,,,, a No L ACE C-AR ACE C-PFP C with integral Phenyl C with integral PFP Yes. NEW,,,, a Yes L Yes. NEW,,,, a Yes L a For optimum column lifetime, a ph range of - is recommended. To increase column lifetime at higher ph, organic buffers, low buffer concentrations, high % organic solvent and low temperatures must be considered. Further information is contained within A Guide to HPLC and LC/MS Buffer Selection by John Dolan please contact your distributor to request your FREE copy or visit. ACE C ACE C-AR ACE C-PFP ACE C remains the go-to column of choice for HPLC and UHPLC separations. With an excellent reputation for performance, reproducibility and lifetime, ACE C provides a rugged, reproducible starting point for method development. Recommended Applications Analytes differing in hydrophobicity Polar, moderately polar and non-polar analytes Uncharged acids and bases Ionized acids or bases using ion-pairing Ideal starting point for method development ACE C-AR combines the excellent performance and advantages of the ACE C phase with the added selectivity of an integral phenyl group. Recommended Applications Analytes with π-bonding and conjugated systems Analytes with electron delocalization and electron withdrawing groups, such as halogens, nitro groups, ketones, esters and acids Analytes with different dipole moments Analytes differing in hydrophobicity Stereoisomers, steroids, substituted aromatics and sulphur containing compounds Fully wettable - 00% aqueous buffer compatible Applications where C does not provide adequate separation Applications where conventional phenyl phases provide insufficient retention, poor stability, or significant bleed. ACE C-PFP brings together the stability, reproducibility and low bleed of the ACE C phase with the additional selectivity of an integral pentafluorophenyl (PFP) group. Recommended Applications Analytes with π-bonding Analytes with electron donating groups, such as phenols, aromatic ethers and amines Analytes with proton donor groups Analytes with different dipole moments Analytes differing in hydrophobicity Stuctural isomers, steroids, substituted aromatics and taxanes Fully wettable - 00% aqueous buffer compatible Applications where C does not provide adequate separation Applications where conventional PFP phases provide insufficient retention, poor stability or significant bleed. Additional Information Product bulletins containing further details on the ACE C, C-AR and C-PFP columns contained within the Advanced ACE Method Development Kit are available to download at Alternatively, please contact our technical support team via info@ace-hplc.com or contact your local distributor. Learn More: ACE HPLC and UHPLC Columns Product Catalogue ACE

5 ACE C - Comparison of Column Inertness Column brands from major manufacturers investigated Comparison of column efficiency for pyridine a basic molecule Peak Efficiency Comparison Application # ACE C Sunfire. C HyPurity C Zorbax XDB. C Zorbax SB. C Luna C() XBridge. C Inertsil ODS- XTerra MS. C Ascentis Express. C,00,00,00,00,00 0,00 0,00,00,00,00 Hypersil BDS C Spherisorb ODS,00,00 Symmetry. C,00 Hypersil ODS 00 0,000,000,000,000 0,000 N 0. (pyridine) (plates/m) Si-OH Column Dimensions: 0 x.mm Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0:0 (v/v) MeOH/H O Flow Rate: 0.0ml/min Temperature: C Detection: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks. ACE Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC & HPLC Separations ACE C Delivers Excellent Performance Rapid UHPLC Screening of Pharmaceuticals and Related Compounds Application # 0 ACE Excel C (fully porous ultra-inert silica) 0 P max = 0 bar ZORBAX Eclipse. XDB C (fully porous silica) 0 0, P max = bar These leading C phases provide an essentially hydrophobic-only interaction, and therefore exhibit similar selectivity with only slight differences between brands observed. Waters ACQUITY. BEH C (hybrid particle) Phenomenex Kinetex. C (core shell particle),, 0 P max = bar P max = bar To implement a change in selectivity, the use of an alternative bonded phase (eg ACE C-AR, ACE C-PFP) that can leverage additional modes of interaction is recommended. 0 Sample: ) N-acetylprocainamide ) -hydroxybenzoic acid ) pindolol ) methylphenylsulphoxide ) benzyl alcohol ) quinoxaline ),-dinitrobenzene ) phenacetin ),-dimethoxybenzene 0) furosemide ) anisole ) methyl benzoate ) remacemide ) nimesulide ) ethyl benzoate ) diflunisal Mobile Phase: A = 0mM KH PO, ph. B = 0mM KH PO, ph. in MeOH/H O (: v/v) Gradient: 00% B in minutes Column Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Detection: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks.

6 Leveraging the Unique Selectivity of ACE C-AR Improving an Analgesics Separation by Changing Phase Application #,, ACE C,, 0 C phase provides essentially hydrophobic-only interaction ACE C-AR 0 Multi-mode interaction including π - π and hydrophobic interactions provides complete separation Sample: ) -acetamidophenol ) -aminobenzoic acid ) -hydroxybenzoic acid ) caffeine ) -acetamidophenol ) -hydroxybenzoic acid ) salicylamide ) acetanilide ) phenol 0) acetylsalicylic acid ) benzoic acid ) sorbic acid ) salicylic acid ) phenylacetin ) salicylaldehyde Mobile Phase: A = 0.% v/v formic acid in H O B = 0.% v/v formic acid in MeCN Gradient: - % B in minutes, hold at % B until minutes Column Dimensions: 0 x.mm Flow Rate:.00ml/min Temperature: 0 C Detection: 0nm ACE C-PFP Provides a Separation that a C or PFP Column Alone Cannot Achieve The Importance of Maintaining Hydrophobicity During Multi-Mode Interactions Application # ACE C-PFP Multi-mode interaction including hydrophobic interaction provides complete separation, ACE C, C phase provides essentially hydrophobic-only interaction Hypersil GOLD µm PFP (example short chain PFP phase) Reduced Hydrophobicity Hydrophobic reference Significantly reduced hydrophobicity reduces the separation despite other interaction modes Column Dimensions: 0 x.mm Sample: ),,-trimethoxybenzene ),,-trimethoxybenzene ),-dimethoxybenzene ),-dimethoxybenzene ) methoxybenzene ),-dimethoxybenzene ),,-trimethoxybenzene ) neutral molecule (reference) Mobile Phase: 0:0 v/v MeOH/H O Flow Rate:.00ml/min Temperature: 0 C Detection: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks.

7 ACE Advanced Method Development UHPLC/HPLC Column Kits (Contains columns: ACE C, ACE C-AR and ACE C-PFP of specified dimensions) (UHPLC/HPLC hardware format with 000bar/000psi pressure limit) Column Dimensions.µm NEW µm µm µm. x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U. x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U. x mm MDKA--0U MDKA--0U MDKA--0U MDKA--0U. x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U. x mm MDKA--0U MDKA--0U MDKA--0U MDKA--0U. x 00mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U. x mm - MDKA--0U MDKA--0U MDKA--0U. x 0mm - MDKA--0U MDKA--0U MDKA--0U. x 0mm - - MDKA--0U MDKA--0U.0 x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U.0 x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U.0 x mm MDKA--0U MDKA--0U MDKA--0U MDKA--0U Selectivity Offer:.0 x mm MDKA--0U MDKA--0U MDKA--0U MDKA--0U.0 x 00mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U.0 x mm - MDKA--0U MDKA--0U MDKA--0U Each column kit is available for the same price as a single column.0 x 0mm MDKA--00U MDKA--00U MDKA--00U MDKA--00U.0 x 0mm - MDKA--0U MDKA--0U MDKA--0U.0 x 0mm - - MDKA--0U MDKA--0U. x 0mm - MDKA--0U MDKA--0U MDKA--0U. x 0mm - MDKA--0U MDKA--0U MDKA--0U. x mm - MDKA--U MDKA--U MDKA--U. x 0mm - MDKA--0U MDKA--0U MDKA--0U. x mm - MDKA--U MDKA--U MDKA--U. x 00mm - MDKA--0U MDKA--0U MDKA--0U. x mm - MDKA--U MDKA--U MDKA--U. x 0mm - MDKA--U MDKA--U MDKA--U. x 0mm - - MDKA--U MDKA--U ACE Advanced Method Development Microbore HPLC Column Kits (Contains columns: ACE C, ACE C-AR and ACE C-PFP of specified dimensions) (HPLC hardware format with 00bar/000psi recommended pressure limit) µm µm µm Column Dimensions / port / port / port / port / port / port 0. x 0mm MDKA--000 MDKA--000S MDKA--000 MDKA--000S MDKA--000 MDKA--000S 0. x 0mm MDKA--000 MDKA--000S MDKA--000 MDKA--000S MDKA--000 MDKA--000S 0. x mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S 0. x 00mm MDKA--000 MDKA--000S MDKA--000 MDKA--000S MDKA--000 MDKA--000S 0. x mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S 0. x 0mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S 0. x 0mm MDKA--00 MDKA--00S.0 x 0mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S.0 x 0mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S.0 x mm MDKA--0 MDKA--0S MDKA--0 MDKA--0S MDKA--0 MDKA--0S.0 x 00mm MDKA--00 MDKA--00S MDKA--00 MDKA--00S MDKA--00 MDKA--00S.0 x mm MDKA--0 MDKA--0S MDKA--0 MDKA--0S MDKA--0 MDKA--0S.0 x 0mm MDKA--0 MDKA--0S MDKA--0 MDKA--0S MDKA--0 MDKA--0S.0 x 0mm MDKA--0 MDKA--0S Important Note: ACE microbore columns (.0mm id and 0.mm id) are available with either standard / (0- thread) connections or / (-0 thread) connections. For use with Eksigent micro and nano LC systems, order columns with / connections and use either ACE -0 fittings (part number ACE-MC0, 0 pack) or Eksigent -0 fittings (part number 0). For / HPLC column connections up to 000psi, PEEK / fingertight fittings (part number ACE-CC0, 0 pack) are recommended. For / microbore HPLC column connections up to 000psi, PEEK / (-0 thread) fingertight fittings (part number ACE-MC0, 0 pack) are recommended. For / UHPLC column connections up to 000psi, reuseable / fittings (part number EXL-CC0, 0 pack) are recommended. To further extend UHPLC and HPLC column lifetimes, ACE pre-column filters are recommended. For further details please contact your distributor or visit

8 Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and 0µm particles for UHPLC and HPLC Ultra-inert for maximum performance and reproducibility UHPLC and HPLC Columns Alternate selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency µm, µm, µm and 0µm particles for UHPLC and HPLC Ultra-inert for maximum performance and reproducibility ACE C-Amide for increased polar retention and alternate selectivity UHPLC and HPLC Columns New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method development High efficiency µm, µm, µm and 0µm particles Ultra-inert for maximum performance and reproducibility ACE CN-ES Combining CN polar selectivity with enhanced UHPLC and HPLC hydrophobicity Columns ACE Extended Method Development Kit Contains ACE SuperC, ACE C-Amide and ACE CN-ES phases Use ACE SuperC to exploit selectivity changes at low, intermediate and high ph Available from microbore (0. mm id) through to analytical (. mm id) dimensions (see p.) ACE C-Amide and ACE CN-ES phases both offer alternative selectivity, especially for polar molecules Phase Functional Group Endcapped ACE SuperC Octadecyl (C) Encapsulated bonding Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Recommended ph Range 00% Aqueous Compatible USP Listing. NEW,,,, a No L ACE C-Amide ACE CN-ES C with integral amide polar group CN with proprietary extended alkyl spacer Yes. NEW,,,, b Yes L/L0 Yes. NEW,,,, b Yes L0 a ACE SuperC is designed for use with LC/MS compatible buffers. Further information is contained within ACE SuperC - A Guide to Buffer Selection please contact your distributor to request your FREE copy or visit. b For optimum column lifetime, a ph range of - is recommended. To increase column lifetime at higher ph, organic buffers, low buffer concentrations, high % organic solvent and low temperatures must be considered. Further information is contained within A Guide to HPLC and LC/MS Buffer Selection by John Dolan please contact your distributor to request your FREE copy or visit ACE SuperC ACE C-Amide ACE CN-ES ACE SuperC is a uniquely bonded, EBT endcapped C phase which offers unprecedented inertness, excellent efficiency and uncompromising durability over an extended ph range of... ACE C-Amide is a uniquely designed polar-embedded phase that offers enhanced retention and resolution of polar acidic, phenolic and hydroxysubstituted analytes. The extended spacer ligand technology provides extended column lifetime. ACE CN-ES is a unique phase having an extended alkyl chain with a terminal cyano group. It provides C levels of retention and stability compared to commercial cyano propyl phases which typically exhibit low retentivity and poor stability. Recommended Applications Analytes differing in hydrophobicity Polar, moderately polar and non-polar analytes Uncharged acids and bases Ionized acids or bases using ion-pairing Recommended starting point for developing methods at intermediate and high ph to exploit selectivity changes Recommended Applications Small water soluble analytes and polar molecules - especially acidic species Analytes with H bond donors, acids, bases and phenolic compounds Small peptides Analytes differing in hydrophobicity Fully wettable - 00% aqueous buffer compatible Applications where C does not provide adequate separation Applications where conventional amide/ polar embedded phases provide insufficient retention, poor stability, or significant bleed Recommended Applications Mixtures of very polar, polar and nonpolar analytes Analytes with double and triple bonds Analytes differing in hydrophobicity Suitable for NP and RP separations Fully wettable - 00% aqueous buffer compatible Applications where a typical C column does not provide adequate separation Applications where traditional CN bonded phases provide insufficient retention, poor stability or significant bleed An orthogonal phase for method development Additional information Product bulletins containing further details on the ACE SuperC, C-Amide and CN-ES columns contained within the Extended ACE Method Development Kit are available to download at Alternatively, please contact our technical support team via info@ace-hplc.com or contact your local distributor. TM ACE SuperC Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE C-Amide For increased polar retention and alternate selectivity ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extra Stability ty Extended Spacer Enhanced Selectivity Learn More: ACE ACE

9 ACE SuperC Provides Excellent Column Inertness Leading column brands in 0 x.mm LC/MS compatible dimensions at intermediate ph. Silica, Hybrid and Superficially Porous particle technologies compared Comparison of column efficiency for pyridine a basic molecule Efficiency measured at % peak height to account for peak tailing effects Peak Efficiency Comparison Application # Reproduced with kind permission of The Open University, UK ACE Excel SuperC,00pl/m ZORBAX Eclipse. XDB C Agilent Poroshell. 0 EC C,00pl/m,00pl/m Higher Efficiency Waters XBridge. BEH C XP 0,00pl/m Waters ACQUITY. BEH C 0,00pl/m Phenomenex Kinetex. C,00pl/m Waters XBridge. C,00pl/m Phenomenex Luna. C() HST a,00pl/m NUCLEOSHELL. RP a,00pl/m Phenomenex Kinetex. C ZORBAX Extend. C 0,00pl/m 0,00pl/m Lower Efficiency Thermo Accucore. C,00pl/m 0 0,000 0,000 0,000 0,000 00,000 N0.0 (pyridine) (plates/m) Column Dimensions: 0 x.mm ( a 0 x.0mm) Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0:0 v/v MeOH/0mM NH OAc in H O (ph.) Flow Rate: 0.0ml/min Temperature: C Detection: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks. Use ACE SuperC to Investigate ph Effects Exploit Selectivity by Adjusting ph Application # 0 ph ph ph.0 ph 0 ph ph ph ph ph 0. ph ph 0 ph 0 ph Column: ACE Excel µm SuperC, 0 x.mm Sample: ) nizatidine ) salbutamol ) amiloride ) N-acetylprocainamide ) quinoxaline ) methyl paraben ) p-cresol ) reserpine ) piperine 0) toluene ) felodipine Temperature: 0 C Flow Rate: 0.ml/min Wavelength: nm Gradient: - 00% B in minutes Acidic Mobile Phase: A: 0mM ammonium formate in H O (ph.0) B: 0mM ammonium formate (ph.0) in 0:0 v/v MeCN/H O Basic Mobile Phase: A: 0.% NH (= mm) in H O (ph 0.) B: 0.% NH (=mm), ph 0. in 0:0 v/v MeCN/H O ph

10 ACE C-Amide Provides Enhanced Polar Selectivity Advantages of Multi-Mode Interactions for HPLC Separations Application # 0 Reproduced with kind permission of The Open University, UK ACE C-Amide (ultra-inert fully porous silica) ACE C-Amide provides increased retention and improved separation due to enhanced polar selectivity 0 ACE C (ultra-inert fully porous silica) 0, Waters ACQUITY. BEH C (hybrid particle) Leading C column brands provide similar selectivity 0 0, Phenomenex Kinetex. C (superficially porous particle) 0 Column Dimensions: 0 x.mm Sample: ) resorcinol ) catechol ) -methyl resorcinol ) -methyl catechol ) -methyl catechol ) -nitro catechol Mobile Phase: : MeOH/mM H PO in H O Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks. ACE CN-ES Provides Alternative Selectivity ACE CN-ES Provides a Separation that a C or CN Column Alone Cannot Achieve Application # 0 ACE CN-ES ACE CN-ES phase provides complete separation due to hydrophobic AND dipole-dipole interactions 0,, ACE CN (example short chain CN phase) CN phase shows insufficient resolution (greatly reduced hydrophobic interaction) 0 ACE C, C phase provides insufficient resolution (no dipole-dipole interaction) 0 Sample: ) metronidazole ) benzyl alcohol ) hydrochlorothiazide ) vanillin ) methyl paraben ),-dinitrobenzene Mobile Phase: A = 0.% formic acid in H O B = 0.% formic acid in 0:0 MeOH/H O Gradient: - 00% B in minutes Column Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: 0 C Wavelength: nm 0

11 ACE Extended Method Development UHPLC/HPLC Column Kits (Contains columns: ACE SuperC, ACE C-Amide and ACE CN-ES of specified dimensions) (UHPLC/HPLC hardware format with 000bar/000psi pressure limit) Column Dimensions.µm NEW µm µm µm. x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U. x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U. x mm MDKE--0U MDKE--0U MDKE--0U MDKE--0U. x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U. x mm MDKE--0U MDKE--0U MDKE--0U MDKE--0U. x 00mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U. x mm - MDKE--0U MDKE--0U MDKE--0U. x 0mm - MDKE--0U MDKE--0U MDKE--0U. x 0mm - - MDKE--0U MDKE--0U.0 x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U.0 x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U.0 x mm MDKE--0U MDKE--0U MDKE--0U MDKE--0U.0 x 0mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U.0 x mm MDKE--0U MDKE--0U MDKE--0U MDKE--0U.0 x 00mm MDKE--00U MDKE--00U MDKE--00U MDKE--00U.0 x mm - MDKE--0U MDKE--0U MDKE--0U.0 x 0mm - MDKE--0U MDKE--0U MDKE--0U.0 x 0mm - - MDKE--0U MDKE--0U. x 0mm - MDKE--0U MDKE--0U MDKE--0U. x 0mm - MDKE--0U MDKE--0U MDKE--0U. x mm - MDKE--U MDKE--U MDKE--U. x 0mm - MDKE--0U MDKE--0U MDKE--0U. x mm - MDKE--U MDKE--U MDKE--U. x 00mm - MDKE--0U MDKE--0U MDKE--0U. x mm - MDKE--U MDKE--U MDKE--U. x 0mm - MDKE--U MDKE--U MDKE--U. x 0mm - - MDKE--U MDKE--U Selectivity Offer: Each column kit is available for the same price as a single column ACE Extended Method Development Microbore HPLC Column Kits (Contains columns: ACE SuperC, ACE C-Amide and ACE CN-ES of specified dimensions) (HPLC hardware format with 00bar/000psi recommended pressure limit) µm µm µm Column Dimensions / port / port / port / port / port / port 0. x 0mm MDKE--000 MDKE--000S MDKE--000 MDKE--000S MDKE--000 MDKE--000S 0. x 0mm MDKE--000 MDKE--000S MDKE--000 MDKE--000S MDKE--000 MDKE--000S 0. x mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S 0. x 00mm MDKE--000 MDKE--000S MDKE--000 MDKE--000S MDKE--000 MDKE--000S 0. x mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S 0. x 0mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S 0. x 0mm MDKE--00 MDKE--00S.0 x 0mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S.0 x 0mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S.0 x mm MDKE--0 MDKE--0S MDKE--0 MDKE--0S MDKE--0 MDKE--0S.0 x 00mm MDKE--00 MDKE--00S MDKE--00 MDKE--00S MDKE--00 MDKE--00S.0 x mm MDKE--0 MDKE--0S MDKE--0 MDKE--0S MDKE--0 MDKE--0S.0 x 0mm MDKE--0 MDKE--0S MDKE--0 MDKE--0S MDKE--0 MDKE--0S.0 x 0mm MDKE--0 MDKE--0S IMPORTANT NOTE: ACE microbore columns (.0mm id and 0.mm id) are available with either standard / (0- thread) connections or / (-0 thread) connections. For use with Eksigent micro and nano LC systems, order columns with / connections and use either ACE -0 fittings (part number ACE-MC0, 0 pack) or Eksigent -0 fittings (part number 0). For / HPLC column connections up to 000psi, PEEK / fingertight fittings (part number ACE-CC0, 0 pack) are recommended. For / microbore HPLC column connections up to 000psi, PEEK / (-0 thread) fingertight fittings (part number ACE-MC0, 0 pack) are recommended. For / UHPLC column connections up to 000psi, reuseable / fittings (part number EXL-CC0, 0 pack) are recommended. To further extend UHPLC and HPLC column lifetimes, ACE pre-column filters are recommended. For further details please contact your distributor or visit

12 ACE UltraCore Method Development Kits Contains ACE UltraCore SuperC and SuperPhenylHexyl phases Use to exploit selectivity changes at low, intermediate and high ph Available from microbore (0. mm id) through to analytical (. mm id) dimensions (see p.) Ultra inert core-shell particles and Encapsulated Bonding Technology (EBT ) provide excellent peak shape Phase Functional Group Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Maximum ph Range ACE UltraCore. SuperC Octadecyl encapsulated a L ACE UltraCore. SuperPhenylHexyl Phenyl-Hexyl encapsulated a L ACE UltraCore SuperC Octadecyl encapsulated a L ACE UltraCore SuperPhenylHexyl Phenyl-Hexyl encapsulated a L USP Listing a ACE UltraCore columns are designed for use with LC/MS compatible buffers. Further information is contained within ACE UltraCore A Guide to Buffer Selection - please contact your distributor to request your FREE copy or visit. ACE UltraCore - Columns Provide Improved Peak Shape ACE UltraCore SuperC and SuperPhenylHexyl phases are manufactured using our unique Encapsulated Bonding Technology (EBT ) This technology dramatically increases ligand coverage of the silica surface and effectively eliminates the negative effects of unbonded silanol groups The higher ligand coverage results in improved inertness, chromatographic performance and stability Si-OH ACE UltraCore Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC & HPLC Separations Use ACE UltraCore to Investigate ph Effects Exploit Selectivity by Adjusting ph Application # 0, ph ph ph.0 0 ph ph ph ph ph ph 0. 0 ph ph ph 0 ph 0 Column: ACE UltraCore.µm SuperC, 0 x.mm Sample: ) atenolol ) methylphenylsulphoxide ) eserine ) prilocaine ) bupivacaine ) tetracaine ),,,-tetrahydro--naphthol ) carvedilol ) nitrobenzene 0) methdilazine ) amitriptyline ) valerophenone Temperature: 0 C Flow Rate: 0.0ml/min Wavelength: nm Gradient: 00% B in minutes Acidic Mobile Phase: A: 0mM ammonium formate in H O (ph.0) B: 0mM ammonium formate (ph.0) in 0:0 (v/v) MeCN/H O Basic Mobile Phase: A: 0.% NH (= mm) in H O (ph 0.) B: 0.% NH (=mm), ph 0. in 0:0 (v/v) MeCN/H O ph

13 ACE UltraCore Columns are Highly Inert Solid-core columns from leading manufacturers investigated Comparison of column efficiency for pyridine a basic molecule Peak Efficiency Comparison Application # 0 Reproduced with kind permission of The Open University, UK Pressure Efficiency ACE UltraCore. SuperPhenylHexyl bar,00pl/m Higher Efficiency ACE UltraCore. SuperC Phenomenex Kinetex. C Phenomenex Kinetex. C Waters Cortecs. C Phenomenex Kinetex. C bar 0 bar bar bar bar,00pl/m,00pl/m,00pl/m,00pl/m,00pl/m Thermo Accucore. C bar,00pl/m 0 0,000 0,000 0,000 0,000 00,000 N0. (pyridine) (plates/m) Lower Efficiency Column Dimensions: 0 x.mm Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0:0 v/v MeOH/0mM NH OAc in H 0 (ph.) Flow Rate: 0.0ml/min Temperature: C Detection: nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks. Introducing Selectivity Changes Using ACE UltraCore Method Development Kits Vitamin Separation Application #, ACE UltraCore SuperC ACE UltraCore SuperPhenylHexyl Multi-mode interaction (including π-π and hydrophobic interactions) provides complete separation Column: 0 x.mm,.µm Sample: ) pyridoxine ) p-aminobenzoic acid ) pantothenic acid ) folic acid ) d-biotin ) cyanocobalamin ) riboflavin Mobile Phase A: 0 mm KH PO ph. (aq) B: 0 mm KH PO ph. in MeOH:H O 0:0 (v/v) Gradient: Time (mins) %B Flow Rate: 0.0 ml/min Temperature: 0 C Wavelength: 0nm min

14 ACE UltraCore Method Development UHPLC/HPLC Column Kits (Contains columns: ACE UltraCore SuperC and ACE UltraCore SuperPhenylHexyl of specified dimensions) (UHPLC/HPLC hardware format with 000bar/000psi pressure limit) Column Dimensions.µm µm. x 0mm MDKU--00U MDKU--00U. x 0mm MDKU--00U MDKU--00U. x mm MDKU--0U MDKU--0U. x 0mm MDKU--00U MDKU--00U. x mm MDKU--0U MDKU--0U. x 00mm MDKU--00U MDKU--00U. x mm MDKU--0U MDKU--0U. x 0mm MDKU--0U MDKU--0U. x 0mm - MDKU--0U.0 x 0mm MDKU--00U MDKU--00U.0 x 0mm MDKU--00U MDKU--00U.0 x mm MDKU--0U MDKU--0U.0 x 0mm MDKU--00U MDKU--00U.0 x mm MDKU--0U MDKU--0U.0 x 00mm MDKU--00U MDKU--00U.0 x mm MDKU--0U MDKU--0U.0 x 0mm MDKU--0U MDKU--0U.0 x 0mm - MDKU--0U. x 0mm MDKU--0U MDKU--0U. x 0mm MDKU--0U MDKU--0U. x mm MDKU--U MDKU--U. x 0mm MDKU--0U MDKU--0U. x mm MDKU--U MDKU--U. x 00mm MDKU--0U MDKU--0U. x mm MDKU--U MDKU--U. x 0mm MDKU--U MDKU--U. x 0mm - MDKU--U Selectivity Offer: Each column kit is available for the same price as a single column ACE UltraCore Method Development Microbore HPLC Column Kits (Contains columns: ACE UltraCore SuperC and ACE UltraCore SuperPhenylHexyl of specified dimensions) Column Dimensions (HPLC hardware format with 00bar/000psi recommended pressure limit).µm µm / port / port / port / port 0. x 0mm MDKU--000 MDKU--000S MDKU--000 MDKU--000S 0. x 0mm MDKU--000 MDKU--000S MDKU--000 MDKU--000S 0. x mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S 0. x 00mm MDKU--000 MDKU--000S MDKU--000 MDKU--000S 0. x mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S 0. x 0mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S 0. x 0mm - - MDKU--00 MDKU--00S.0 x 0mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S.0 x 0mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S.0 x mm MDKU--0 MDKU--0S MDKU--0 MDKU--0S.0 x 00mm MDKU--00 MDKU--00S MDKU--00 MDKU--00S.0 x mm MDKU--0 MDKU--0S MDKU--0 MDKU--0S.0 x 0mm MDKU--0 MDKU--0S MDKU--0 MDKU--0S.0 x 0mm - - MDKU--0 MDKU--0S IMPORTANT NOTE: ACE microbore columns (.0mm id and 0.mm id) are available with either standard / (0- thread) connections or / (-0 thread) connections. For use with Eksigent micro and nano LC systems, order columns with / connections and use either ACE -0 fittings (part number ACE-MC0, 0 pack) or Eksigent -0 fittings (part number 0). For / HPLC column connections up to 000psi, PEEK / fingertight fittings (part number ACE-CC0, 0 pack) are recommended. For / microbore HPLC column connections up to 000psi, PEEK / (-0 thread) fingertight fittings (part number ACE-MC0, 0 pack) are recommended. For / UHPLC column connections up to 000psi, reuseable / fittings (part number EXL-CC0, 0 pack) are recommended. To further extend UHPLC and HPLC column lifetimes, ACE pre-column filters are recommended. For further details please contact your distributor or visit

15 ACE Bioanalytical 00Å Method Development Kits Contain ACE C-00, ACE C-00 and ACE Phenyl-00 phases Ideal starting point for protein and peptide method development Available from microbore (0. mm id) through to analytical (. mm id) dimensions (see p. ) Ultra-inert 00Å phases provide excellent peak shape and reproducibility Phase Functional Group Particle Size (µm) Pore Size (Å) Surface Area (m /g) Carbon Load (%) Recommended ph Range USP Listing ACE C-00 Octadecyl (C),, a L ACE C-00 Butyl (C),, a L ACE Phenyl-00 Phenyl,, a L a For optimum column lifetime, a ph range of - is recommended. To increase column lifetime at higher ph, organic buffers, low buffer concentrations, high % organic solvent and low temperatures must be considered. Further information is contained within A Guide to HPLC and LC/MS Buffer Selection by John Dolan please contact your distributor to request your FREE copy or visit. ACE 00Å Ultra-Inert Columns Provide Improved Peak Shape ACE 00Å ultra-inert HPLC columns are manufactured using advanced technology that virtually eliminates the negative effects of silanols and metal contamination for the separation of peptides, proteins and other high molecular weight biomolecules. The ultra-inert characteristics of ACE 00Å columns permit the use of as little as 0.00% TFA in the mobile phase. Competitor columns often show unacceptable peak tailing even when using as much as 0.0% TFA. The ability to run at reduced TFA concentrations results in increased sensitivity. ACE 00Å Bioanalytical Columns Provide Excellent Peak Shape Application # 00 ACE C-00 (Ultra-inert silica) Vydac TP (Lower purity active silica) 0.% TFA 0.0% TFA 0.00% TFA Columns: 0 x.mm, µm Sample: ) Gly-Tyr ) Oxytocin ) Angiotensin II ) Neurotensin Mobile Phase: A = TFA in H O (% as specified above) B = TFA in MeCN (% as specified above) Gradient: 0 - % B in. minutes Flow Rate:.0ml/min Temperature: C Wavelength: 00nm Comparative data may not be representative of all applications. Please see back page for acknowledgement of trademarks.

16 Using ACE Bioanalytical 00Å Method Development Kits to Optimise Selectivity Introducing Selectivity Changes by Careful Consideration of Bonded Phase and Mobile Phase Additive 0.% TFA 0.% Formic Acid Application # 00 ACE C-00 Response - Millivolts Response - Millivolts,, ACE C-00 ACE Phenyl-00 Response - Millivolts Response - Millivolts Response - Millivolts Response - Millivolts The ACE 00Å C, C and Phenyl chemistries contained within ACE Bioanalytical 00Å Method Development Kits enable the analyst to investigate selectivity effects due to phase variations. The ultra-inert characteristics of the ACE 00Å silica enable different mobile phase additives to be investigated without a deterioration in peak shape or sensitivity. Columns: 0 x.mm, µm Sample: ) Gly-Tyr ) Val-Tyr-Val ) Methionine enkephalin ) Angiotensin II ) Leucine enkephalin Mobile Phase: A = 0.% TFA in H O or 0.% Formic Acid in H O (as specified above) B = MeCN Gradient: 0 0% B in minutes Flow Rate:.00ml/min Temperature: C Wavelength: 0nm

17 ACE Bioanalytical 00Å Method Development HPLC Column Kits (Contains columns: ACE C-00, ACE C-00 and ACE Phenyl-00 of specified dimensions) (HPLC hardware format with bar/000psi pressure limit) Column Dimensions µm µm. x 0mm MDKB--00 MDKB--00. x 0mm MDKB--00 MDKB--00. x mm MDKB--0 MDKB--0. x 0mm MDKB--00 MDKB--00. x mm MDKB--0 MDKB--0. x 00mm MDKB--00 MDKB--00. x mm MDKB--0 MDKB--0. x 0mm MDKB--0 MDKB--0. x 0mm - MDKB--0.0 x 0mm MDKB--00 MDKB x 0mm MDKB--00 MDKB x mm MDKB--0 MDKB--0.0 x 0mm MDKB--00 MDKB x mm MDKB--0 MDKB--0.0 x 00mm MDKB--00 MDKB x mm MDKB--0 MDKB--0.0 x 0mm MDKB--0 MDKB--0.0 x 0mm - MDKB--0. x 0mm MDKB--0 MDKB--0. x 0mm MDKB--0 MDKB--0. x mm MDKB-- MDKB--. x 0mm MDKB--0 MDKB--0. x mm MDKB-- MDKB--. x 00mm MDKB--0 MDKB--0. x mm MDKB-- MDKB--. x 0mm MDKB-- MDKB--. x 0mm - MDKB-- Selectivity Offer: Each column kit is available for the same price as a single column Note:.0mm id ACE Bioanalytical 00Å Method Development Kits also available please enquire ACE Bioanalytical 00Å Method Development Microbore HPLC Column Kits (Contains columns: ACE C-00, ACE C-00 and ACE Phenyl-00 of specified dimensions) (HPLC hardware format with bar/000psi recommended pressure limit) µm µm Column Dimensions / port / port / port / port 0. x 0mm MDKB--000 MDKB--000S MDKB--000 MDKB--000S 0. x 0mm MDKB--000 MDKB--000S MDKB--000 MDKB--000S 0. x mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S 0. x 00mm MDKB--000 MDKB--000S MDKB--000 MDKB--000S 0. x mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S 0. x 0mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S 0. x 0mm - - MDKB--00 MDKB--00S.0 x 0mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S.0 x 0mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S.0 x mm MDKB--0 MDKB--0S MDKB--0 MDKB--0S.0 x 00mm MDKB--00 MDKB--00S MDKB--00 MDKB--00S.0 x mm MDKB--0 MDKB--0S MDKB--0 MDKB--0S.0 x 0mm MDKB--0 MDKB--0S MDKB--0 MDKB--0S.0 x 0mm - - MDKB--0 MDKB--0S IMPORTANT NOTE: ACE microbore columns (.0mm id and 0.mm id) are available with either standard / (0- thread) connections or / (-0 thread) connections. For use with Eksigent micro and nano LC systems, order columns with / connections and use either ACE -0 fittings (part number ACE-MC0, 0 pack) or Eksigent -0 fittings (part number 0). For / HPLC column connections up to 000psi, PEEK / fingertight fittings (part number ACE-CC0, 0 pack) are recommended. For / microbore HPLC column connections up to 000psi, PEEK / (-0 thread) fingertight fittings (part number ACE-MC0, 0 pack) are recommended. For / UHPLC column connections up to 000psi, reuseable / fittings (part number EXL-CC0, 0 pack) are recommended. To further extend UHPLC and HPLC column lifetimes, ACE pre-column filters are recommended. For further details please contact your distributor or visit

18 UHPLC, HPLC and Microbore Column Accessories UHPLC Column Connectors Pressure rating >00 bar (>000 psi) Compatible with all UHPLC systems Compatible with all UHPLC column brands Eliminates poor connections Innovative reusable design Wrench Flat ¼ (0.cm) Proprietary PEEK cone Reuseable column connector with 0- threads for / od tubing ACE Excel UHPLC Column Connector (p/n EXL-CC0, 0 pack) All UHPLC column brands require correct installation in order to realise maximum column efficiency. To avoid connection problems, permanently swaged fittings are not recommended as they do not allow free movement between the tubing, fitting and column inlet on installation. This can result in a poorly connected column that shows unexpected peak tailing due to the introduction of extra column volume (dead volume) to the system. Alternatively, a leak at the inlet fitting connection may be observed. ACE Excel UHPLC Column Connectors (p/n EXL-CC0, 0 pack) enable the inlet end of UHPLC columns to be correctly installed every time. Their unique reuseable design ensures that they maintain a 00 bar (000 psi) pressure rating with repeated use, yet do not permanently swage onto the inlet tubing. To maximise the lifetime of the fitting, the use of a torque wrench (p/n EXL-TW) is required. At the outlet end of the UHPLC column (where pressure demands are lower but a correct connection remains important), ACE Fingertight HPLC Column Connectors (p/n ACE-CC0, 0 pack, see below) may alternatively be used. Note: For inlet connections onto a Waters Acquity system (containing a Waters Acquity / fitting and ferrule on the inlet tubing) the use of a pre-column filter incorporating the unique Waters Acquity column port profile is alternatively recommended (p/n EXL-PCF0/ACQ - 0 pack) to ensure maximum compatibility with the Waters Acquity system fittings. HPLC Column Connectors Fingertight to 0 bar (000 psi) Reuseable and simple to install Eliminates poor connections Compatible with all HPLC column brands and instruments ACE Fingertight HPLC Column Connectors (p/n ACE-CC0, 0 pack) are recommended for the connection of both the inlet and outlet ends of HPLC columns. Manufactured from premium quality PEEK, the fittings simply hand tighten to provide a perfect column connection, and are pressure rated to 0 bar/000 psi. ACE Fingertight HPLC Column Connectors may additionally be used at the outlet end of UHPLC columns, where pressure demands are lower but a correct connection remains important. ACE Fingertight HPLC Column Connector (p/n ACE-CC0, 0 pack) Microbore HPLC Column Connectors Fingertight to 00 bar (000 psi) Reuseable and simple to install Compatible with both capillary (0µm od) and / od connection tubing Reuseable connector with -0 threads for / od tubing ACE Microbore / Column Connectors (p/n ACE-MC0, 0 pack) are recommended for the connection of inlet and outlet ends of ACE Microbore HPLC columns with / ports. Each pack comes complete with 0 fittings and 0 capillary sleeves (which enable the fittings to be used with 0µm od tubing), plus a fingertight tightening adaptor. These fittings are additionally compatible with any other brand of microbore column terminating with / ports and -0 threads. ACE Microbore / Column Connector (p/n ACE-MC0, 0 pack)

19 Your decision has lasting effects. Ultra-Inert Base-Deactivated UHPLC/HPLC Columns For Performance, Selectivity and Guaranteed Reproducibility ACE and Excel are registered trademarks of Advanced Chromatography Technologies Limited. ACE SuperC, ACE UltraCore, EBT and HSC are trademarks of Advanced Chromatography Technologies Limited. Advanced Chromatography Technologies Limited acknowledges the registered and unregistered trademarks of Alltech Associates Inc., Eksigent Technologies, GL Sciences, MACHEREY-NAGEL GmbH & Co KG, Phenomenex Inc., Sigma-Aldrich Co., Thermo Fisher Scientific, Victrex Plc and Waters Corporation and has no affiliation with any of these companies. Columns

20 www. l ubex. com. cn 广州绿百草生物科技有限公司 Tel 0000 / Fax 00 / www. l ubex. com. cn / emai l s uppor ubex. com. cn

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and

More information

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,

More information

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,

More information

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency

More information

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,

More information

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially

More information

ACE Ultra Inert Base Deactivated HPLC Columns

ACE Ultra Inert Base Deactivated HPLC Columns ACE Ultra Inert Base Deactivated HPLC Columns Contents Page ACE HPLC Columns...- Independent Comparison of HPLC Columns #... Independent Comparison of HPLC Columns #... ACE 00Å HPLC Columns Specifications...-

More information

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

ACE ACE. HPLC and UHPLC Columns. Product Catalogue ACE HPLC and UHPLC Columns Product Catalogue ACE Ultra-Inert, Base Deactivated HPLC & UHPLC Columns ACE Ultra-Inert, Base Deactivated HPLC and ACE Excel UHPLC columns give you the choices you need to

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs) A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Zorbax Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email:

More information

LC and LC/MS Column Selection Flow Chart

LC and LC/MS Column Selection Flow Chart LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the

More information

Leveraging Bonded Phase Selectivity. to Achieve Better Reversed Phase HPLC Separations

Leveraging Bonded Phase Selectivity. to Achieve Better Reversed Phase HPLC Separations Leveraging Bonded Phase Selectivity to Achieve Better Reversed Phase HPLC Separations Introduction There has been a great deal of emphasis in the past several years on column efficiency (theoretical plates,

More information

Analgesics / Cough 1 & Cold Medicine Ingredients

Analgesics / Cough 1 & Cold Medicine Ingredients Analgesics / Cough & Cold Medicine Ingredients mau H. paracetamol H CH H H. -aobenzoic acid H H H C CH. -hydroxybenzoic acid 7 CH H CH. caffeine 8 9 H. -acetamidophenol 0 H H. -hydroxybenzoic acid H C8-AR

More information

Epic Aromatic Selectivity

Epic Aromatic Selectivity Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,

More information

State-of-the-art C18 HPLC Columns

State-of-the-art C18 HPLC Columns An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%

More information

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Orosil OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph. Excellent organic base selectivity with very low asymmetry values Compatible

More information

Packings for HPLC. Packings for HPLC

Packings for HPLC. Packings for HPLC Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.

More information

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,

More information

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns ProntoSIL C8-EPS Reversed-Phase HPLC Columns Provides excellent separation of polar compounds Better peak shape for acids and bases Stabilized bonded phase for rugged, robust HPLC methods More retentive

More information

ACE C18-PFP. A C18 bonded phase with unique selectivity. s Guaranteed reproducibility. lity. s Exceptional bonded phase stability

ACE C18-PFP. A C18 bonded phase with unique selectivity. s Guaranteed reproducibility. lity. s Exceptional bonded phase stability ACE CPFP A C bonded phase with unique selectivity & & & & & s Guaranteed reproducibility lity s Exceptional bonded phase stability s Hydrophobic and pentafluorophenyl mixed mode interaction HPLC Columns

More information

Hypersil BDS Columns TG 01-05

Hypersil BDS Columns TG 01-05 TG 0-0 Hypersil BDS Columns Introduction Hypersil BDS columns have gained a reputation over the years as one of the most robust, reproducible and reliable HPLC column brands available. This Technical Guide

More information

Reversed Phase Solvents

Reversed Phase Solvents Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography

More information

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column

More information

InertSustainSwift C8

InertSustainSwift C8 HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which

More information

A Look at Agilent HPLC Columns Choices

A Look at Agilent HPLC Columns Choices A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle

More information

Comparison Guide to C18 Reversed Phase HPLC Columns

Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Guide to C18 Reversed Phase HPLC Columns Comparison Data on Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron

More information

Part 2. Overview of HPLC Media

Part 2. Overview of HPLC Media Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully

More information

InertSustainSwift C8

InertSustainSwift C8 Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica Gel :.9 μm, μm, μm :00 m /g :00 Å (0 nm)

More information

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar

More information

1.7 m Fortis UHPLC Columns

1.7 m Fortis UHPLC Columns Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower

More information

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications COMPARISON GUIDE to C18 Reversed Phase HPLC Columns Comparison Data on 60 Commonly Used C18 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Phases Compared According

More information

Alltech Alltima HP Introduction

Alltech Alltima HP Introduction Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life

More information

HPLC UHPLC Columns. Dikma Technologies Inc.

HPLC UHPLC Columns. Dikma Technologies Inc. Technologies Inc. About HPLC UHPLC Columns has over years of R&D experience in HPLC / UHPLC columns. HPLC / UHPLC columns have been widely used by pharmaceutical manufacturers. We offer columns of ultimate

More information

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing

More information

Fluophase and Fluofix Columns

Fluophase and Fluofix Columns TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS Vydac Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

1.7µm Fortis UHPLC Columns

1.7µm Fortis UHPLC Columns Strength in Technology.7µm Fortis Columns NEW Phase Chemistries - Fortis Ho (polar endcapped) - Fortis Amino - Fortis HILIC Diol Ultra High Pressure Chromatography 8 Chemistry Choices Increase Efficiency

More information

Optimisil HPLC & UPLC Column catalogue

Optimisil HPLC & UPLC Column catalogue Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com

More information

The Evolving HPLC Column Packings

The Evolving HPLC Column Packings The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established

More information

LC Technical Information

LC Technical Information LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC

More information

Method Development Kits

Method Development Kits Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention

More information

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion HPLC Columns Agilent for Small Molecule InfinityLab Poroshell 0 ZORBAX Eclipse Plus ZORBAX Eclipse XDB ZORBAX 80Å StableBond ZORBAX 80Å Extend-C8 ZORBAX Bonus-RP ZORBAX Eclipse PAH ZORBAX HILIC Plus ZORBAX

More information

Inertsil ODS-EP Technical Information

Inertsil ODS-EP Technical Information Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can

More information

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and

More information

New Product Update. HPLC Columns

New Product Update. HPLC Columns New Product Update HPLC Columns ZORBAX MicroBore HPLC Columns ZORBAX Extend-C18 Columns ZORBAX Bonus-RP Columns Inertsil ODS-2 Cartridge Columns ZORBAX Carbohydrate Analysis Columns ZORBAX Eclipse dsdna

More information

Choosing Columns and Conditions for the Best Peak Shape

Choosing Columns and Conditions for the Best Peak Shape Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include

More information

Inertsil Technical Library

Inertsil Technical Library HPLC COLUMN INERTSIL TECHNICAL LIBRARY H P L C C o l u m n Inertsil Technical Library Inertsil ODS-4, C8-4 Comparison of Performance List of Compared Columns Experimental Explanation, Analytical Conditions

More information

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range Capital HPLC Columns and HPLC Cartridges Specialty Columns HPLC Columns & HPLC Cartridges Download Capital Catalog Adsorbosphere Apex Chromegabond Diasogel Exsil Hypersil Inertsil ODS-2 Partisil Rosil

More information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns P R O D U C T B U L L E T I N Fused-Core particle technology for hyper-fast and super-rugged HPLC columns HALO column packings are not made the typical way. Instead, the particles packed into HALO columns

More information

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules www.interchim.com www.blog.interchim.com www.forum.interchim.com www.facebook.com/interchim

More information

1.7µm Fortis C18 UHPLC Columns

1.7µm Fortis C18 UHPLC Columns Strength in Technology.7µm Fortis C8 Columns Ultra High Pressure Chromatography Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Wider Linear flow rate range .7µm Columns - 8m/g

More information

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases

InertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica

More information

for Acclaim Mixed-Mode HILIC-1 Column

for Acclaim Mixed-Mode HILIC-1 Column for Acclaim Mixed-Mode HILIC-1 Column Product Manual for ACCLAIM Mixed-Mode HILIC-1 Page 1 of 17 Product Manual for ACCLAIM Mixed-Mode HILIC-1 Column 5µm, 4.6 x 250mm, P/N 066844 5µm, 4.6 x 150mm, P/N

More information

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application Pharmaceuticals Authors John W. Henderson Jr., Nona Martone, and Cliff Woodward

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

Small Molecule Selectivity Sampler

Small Molecule Selectivity Sampler Small Molecule Selectivity Sampler HALO 90 Å C18, AQ-C18, BIPHENYL Fused-Core Particle Technology Why Choose Fused-Core Particle Technology? Fused-Core Out-Performs Totally Porous Particles. HALO particles

More information

BETASIL Columns TG Å high purity silica

BETASIL Columns TG Å high purity silica BETASIL Columns TG0-0 00Å high purity silica Technical Guide BETASIL Columns Introduction 00Å high purity silica High surface area and phase loading Designed for small molecules Type B silica gives good

More information

Overview Applications of NUCLEODUR HPLC Phases

Overview Applications of NUCLEODUR HPLC Phases verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-

More information

Bringing uhplc Performance to the Separation of Peptides

Bringing uhplc Performance to the Separation of Peptides P e p t i d e E S - C 1 8 U H P L C C o l u m n s Bringing uhplc Performance to the Separation of Peptides Compatible with UHPLC and conventional HPLC equipment. Sumpfstr. 3, CH-6300 Zug; Fax: 041 748

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SeQuant ZIC-HILIC Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 PE, UK Tel: + (0)8 90 660 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk

More information

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Thermo Scientific Accucore XL HPLC Columns. Technical Manual Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users

More information

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents No. 089 SEPARATION REPORT Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS Table of Contents 1. Introduction 1 2. Column Specification 1 3. Features of Packing Materials

More information

NUCLEODUR (Macherey-Nagel)

NUCLEODUR (Macherey-Nagel) NUCLEDUR (Macherey-Nagel) Ultrapure silica Excellent mechanical and chemical stability Low metal content Enhanced ph stability Manufactured by Macherey-Nagel GmbH & Co. KG, Düren, Germany, NUCLEDUR is

More information

William E. Barber, Ph.D. Applications Chemist October

William E. Barber, Ph.D. Applications Chemist October William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC

More information

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 Cogent HPLC Columns Manufactured by Table of Contents QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3 C8 Bidentate C8 Extremely long

More information

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial

More information

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC LC800 Smart HPLC Until now UHPLC From now Smart HPLC Smart HPLC Leads to Ultimate Performance Patent Pending S LC800 is a completely new and unique concept, designed for maximum performance in high resolution

More information

How proteins separate on reverse-phase HPLC

How proteins separate on reverse-phase HPLC 1 Reverse Phase How proteins separate on reverse-phase HPLC RP chromatography separates proteins through the interaction of the hydrophobic foot of the protein with a nonpolar surface of the particle RP

More information

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk

More information

LIQUID CHROMATOGRAPHY

LIQUID CHROMATOGRAPHY LIQUID CHROMATOGRAPHY RECENT TECHNIQUES HPLC High Performance Liquid Chromatography RRLC Rapid Resolution Liquid Chromatography UPLC Ultra Performance Liquid Chromatography UHPLC Ultra High Pressure Liquid

More information

UPLC Method Development and Validation

UPLC Method Development and Validation UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy

More information

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route

More information

8. Methods in Developing Mobile Phase Condition for C18 Column

8. Methods in Developing Mobile Phase Condition for C18 Column I. HPLC Columns Technical Information 8. Methods in Developing Mobile Phase Condition for C18 Column Introduction In reversed phase HPLC, octadecyl group bonded silica columns (C18, ODS) are the most widely

More information

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM Eric S. Grumbach Thomas E. Wheat Chuck Phoebe Joe Arsenault Jeffrey R. Mazzeo Diane M. Diehl UPLC TECHNOLOGY

More information

Successfully Scaling and Transferring HPLC and UPLC Methods

Successfully Scaling and Transferring HPLC and UPLC Methods Successfully Scaling and Transferring HPLC and UPLC Methods Esa Lehtorinne Esa_Lehtorinne@waters.com Tel: +358-9-5659 6288 Fax: +358-9-5659 6282 Waters Finland Kutomotie 16 00380 Helsinki 2013 Waters Corporation

More information

Technical Guide Thermo Scientific Syncronis HPLC Columns

Technical Guide Thermo Scientific Syncronis HPLC Columns Technical Guide Thermo Scientific Syncronis HPLC Columns Consistent, predictable separations, Column after column, time after time Thermo Scientific Syncronis Columns When developing a new method, one

More information

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,

More information

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability Tracer Excel TRACER EXCEL is a range of totally new packings that employ the most advanced procedures of synthesis and chemical functionalization, resulting in some column packings that completely surpass

More information

NUCLEOSHELL core-shell silica for HPLC

NUCLEOSHELL core-shell silica for HPLC NUCLESHELL core-shell silica for HPLC Core-shell technology µm 0. µm.8 µm 0. µm.7 µm 0. µm.7 µm 0. µm Key feature Solid core of silicon dioxide, homogeneous shell of porous silica Highest efficiency compared

More information

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Fast Separation of Vastly Different Compounds by Isocratic HPLC Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite

More information

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 2 Columns Application Note Pharma, BioPharma, and Clinical Research Author William Long Agilent Technologies, Inc. Introduction Steroids

More information

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles Richard A. Henry, Separation Technology Consultant On behalf of: Supelco/Sigma-Aldrich, Bellefonte, USA

More information

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-exyl Columns to Separate Estrogens Application Note Pharmaceutical, Environmental Authors John W. enderson Jr. and William J. Long Agilent

More information

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties AN HPLC COLUMN TM InertSustain C8 AN HPLC COLUMN InertSustain TM C8 Inertsil continues to evolve to InertSustain Physical Properties Silica : Newly Developed Silica Gel Particle Size : m, m, m Surface

More information

Your Reversed Phase Method

Your Reversed Phase Method PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust

More information

Fast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC

Fast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC Fast Screening Methods for Analgesics and on-steroidal Anti-Inflammatory Drugs by HPLC Application ote Small Molecule Pharmaceuticals and Generics Author William Long Agilent Technologies, Inc. Introduction

More information

Columns and supplies catalog

Columns and supplies catalog Columns and supplies catalog PLC GC TLC SPE and lash Syringe filters Vials and caps... we Meet your Needs MACEREY-NAGEL Company profile Since 1911 MACEREY-NAGEL has represented high quality, innovation

More information

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s

More information

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science HPLC Column Selection: Solve the Separation Mystery The world leader in serving science verview Introduction Historical verview in Stationary Phases Basics in Column Selection Resolution, Efficiency and

More information

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns Analysis of Positional Isomers with Agilent Poroshell PFP olumns Application ote Environmental Authors William Long and Jonathan Horton Agilent Technologies, Inc. Introduction The Agilent Poroshell PFP

More information

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies HPLC Method Development with Eclipse Plus: Standard Practices and New Columns Agilent Technologies What are Some Standard Method Development Practices?. Follow preferred method development scheme and do

More information

CLIPEUS - A Small Shield for a Big Job

CLIPEUS - A Small Shield for a Big Job CLIPEUS - A Small Shield Virgil s Aeneid gave us a sanguine account of the problems encountered when working without a Clipeus a small shield popularized by the Romans. While arguably a less painful experience,

More information

SGE is excited to launch a new HPLC product line under the ProteCol brand.

SGE is excited to launch a new HPLC product line under the ProteCol brand. The Role of Pore Size in Reversed Phase HPLC SGE is excited to launch a new HPLC product line under the ProteCol brand. Fundamental to the new ProteCol line of columns is the continued focus on inert column

More information

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm

More information

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH

More information

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which

More information