Your Reversed Phase Method
|
|
- Joanna Craig
- 6 years ago
- Views:
Transcription
1 PLC Columns for Your Reversed Phase Method Balanced Non-Polar & Polar Selectivity Strong Non-Polar & Polar Selectivity Strong Polar & Aromatic Selectivity Unique Isomeric & alogenated Selectivity Robust C8 Selectivity
2 PFP() Choose the Optimal PLC Column for Your Application Choosing the right column can ease method development and result in improved resolution.* Analytes Polar Non Polar Polar/Non-Polar Mixtures Recommended PLC column Synergi Polar-RP Gemini -NX Synergi ydro-rp Stronger non-polar retention Synergi Fusion-RP Balanced non-polar & polar retention For Alternative Selectivity Luna PFP() Selectivity for isomeric, aromatic, and halogenated compounds OR Luna ILIC** For very polar compounds consider ILIC mode Luna PFP() More aromatic selectivity Synergi ydro-rp More hydrophobic selectivity *These are suggestions and individual results may vary, depending on your sample and separation goal. **Contact us for more information on Luna ILIC columns or visit Trademarks Luna and Gemini are registered trademarks of Phenomenex, Inc. SecurityGuard and Synergi are trademarks of Phenomenex, Inc. Waters is a registered trademark, and SymmetryShield is a trademark of Waters Corp. Disclaimer Comparative separations may not be representative of all applications. Subject to Phenomenex Standard Terms & Conditions, which may be viewed at Phenomenex, Inc. All rights reserved.
3 Gemini -NX C8 Robust C8 Performance at p Stable - Mobile phase p directly impacts retention and resolution of most drug compounds. Using Gemini-NX, method development is nearly unlimited due to the advanced column technology that provides wider p stability and longer column lifetime. By using mobile phase p to change the ionization state of your compound, you can increase retention of your compounds. Ionized state Nicotine spends less time interacting with the C8 stationary phase and elutes in the void volume App ID 666 p.8 Charged Analyte O N O - N + O Nicotine in 0. % Formic Acid, p.8 Column: Gemini-NX 5 µm C8 Part No.: 00F-5-E0 Mobile Phase: A: 0. % Formic Acid in Water B: 0. % Formic Acid in Acetonitrile Gradient: A/B (95:5) to (5:95) in 0 min, old for min Flow Rate:.5 ml/min Temperature: Ambient Detection: 5 nm Sample: Nicotine; pk a min Neutral state Nicotine has distinct chromatographic behaviors: Increased retention - nicotine spends more time interacting with the stationary phase Sharp peak - single neutral form, well resolved App ID 667 p 0.5 Uncharged Analyte O - O - O - N O - N O O - Nicotine in Ammonium Bicarbonate, p 0.5 Column: Gemini-NX 5 µm C8 Part No.: 00F-5-E0 Mobile Phase: A: 0 mm Ammonium Bicarbonate p 0.5 B: Acetonitrile Gradient: A/B (95:5) to (5:95) in 0 min, old for min Flow Rate:.5 ml/min Temperature: Ambient Detection: 5 nm Sample: Nicotine ; pk a min 3
4 Synergi YDRO-RP Strong Non-polar Selectivity with Polar Retention For sample mixtures that require separation of non-polar and polar analytes, Synergi ydro-rp exhibits very hydrophobic retention compared to most traditional C8 columns, due to unique polar end-capping combined with a densely bonded C8 ligands. Synergi ydro-rp vs. Traditional 5 µm C8 +3 Greater retention, polar selectivity! Increased hydrophobic retention! App ID App ID 5 Columns: Synergi µm ydro-rp 80Å Traditional 5 µm C8 00Å Part No.: 00F-375-E0 Mobile Phase: 0 mm Potassium phosphate, p 7.0 /Methanol (60:0) Flow Rate:.0 ml/min Temperature: C Detection: 0 nm Sample:. Phenylephrine. Phenylpropanolamine 3. Pseudoepherine. Methylparaben
5 Synergi FUSION-RP Balanced Non-polar Selectivity with Polar Retention For improved run times for extremely hydrophobic compounds and increased retention for polar compounds, Synergi Fusion-RP provides the right balance for mixtures of non-polar and polar analytes. Synergi µm Fusion-RP vs. Traditional 5 µm C8 Longer Polar Retention 3 Less ydrophobic Retention Balanced retention! min App ID 80 Columns: Synergi µm Fusion-RP Traditional 5 µm C8 Part No.: 00F--E0 Mobile Phase: 0 mm Potassium Phosphate, p.5 / Acetonitrile (75:5) Flow Rate:.0 ml/min Detection: 0 nm Sample:. Maleic acid. Chlorpheniramine 3. Triprolidine. Diphenhydramine min 5
6 Synergi POLAR-RP Strong-polar Retention with Aromatic Selectivity ighly polar compounds are difficult to retain on traditional C8 columns. A specialized ether-linked phenyl group gives better selectivity for aromatic compounds while providing maximum polar retention. Synergi µm Polar-RP vs. Waters SymmetryShield C8 Improved selectivity! App ID 55 App ID 85 Columns: Synergi µm Polar-PR Waters 5 µm SymmetryShield C8 Part No.: 00F-336-E0 Mobile 0 mm Potassium phosphate Phase: p 3 / Methanol (50:50) Flow Rate:.0 ml/min Detection: 30 nm Injection: µl Temperature: C Sample:. Metaproterenol (0. µg). Pindolol (0.6 µg) 3. Metoprolol (0.5 µg). Alprenolol (0.3 µg) 5. Propranolol (0.0 µg) 6. Ethylparaben (0. µg) 6
7 PFP() Luna PFP() Separate Compounds that are Isomeric, Aromatic, & alogenated When a truly different type of reversed phase selectivity is needed, Luna PFP() is an excellent choice, even under typical C8 mobile phase conditions. A pentafluorophenyl-propyl ligand uses multiple mechanisms of interaction for improved separation of isomers, aromatics, and halogenated compounds. Positional Isomers of alogenated Phenols alogens can radically increase the polarity of a compound, thus decreasing typical retention characteristics. Luna PFP() columns retain, discriminate, and separate halogens easily. Luna 3 µm PFP() Baseline separation min 9 0 App ID 696 Luna 3 µm C8() min & 0 Coelution! App ID 697 Columns: Luna 3 µm PFP() Luna 3 µm C8() Part Nos.: 00F-7-E0 00F-5-E0 Mobile Phase: A: 0. % Formic acid in Water B: 0. % Formic acid in Acetonitrile Gradient: A/B (60:0) to (50:50) in 0 min Flow Rate:.0 ml/min Temperature: C Detection: 5 nm Sample:.,3-Dimethylphenol.,5-Dimethylphenol 3.,6-Dimethylphenol. 3,-Dimethylphenol 5. 3,5-Dimethylphenol 6.,5-Dichlorophenol 7.,6-Dichlorophenol 8. 3,-Dichlorophenol 9. 3,5-Dichlorophenol 0.,-Dibromophenol Positional Isomers of Methylacetophenone Positional changes on an analyte of interest may effect the compound s dipole moment. This change can be readily noticed by the highly electronegative fluorine (F) atom and other retention mechanisms. Luna 3 µm PFP() mechanisms of interaction provide good resolution of isomers! 3 App ID 698 Luna 3 µm C8() mechanism of interaction unable to resolve isomers! 3 App ID 699 Columns: Luna 3 µm PFP() Luna 3 µm C8() Part Nos.: 00F-7-E0 00F-5-E0 Mobile Phase: Water/ Methanol (50:50) Flow Rate:.0 ml/min Temperature: C Detection: 5 nm Sample:. o-methylacetophenone. m-methylacetophenone 3. p-methylacetophenone min min 7
8 Ordering Information Gemini -NX 3 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 50 x.0 x.0* C8 00B-53-B0 00F-53-B0 AJ μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 x 3.0* C8 00B-53-E0 00F-53-E0 AJ for ID: mm 5 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 x.0* C8 00B-5-B0 AJ μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 50 x.6 x 3.0* C8 00B-5-E0 00F-5-E0 00G-5-E0 AJ for ID mm Luna PFP() 3 μm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.0 00 x.0 50 x.0 x.0 * PFP() 00B-7-B0 00D-7-B0 00F-7-B0 AJ μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x x.6 x.0* x 3.0 * PFP() 00F-7-Y0 00F-7-E0 AJ0-836 AJ mm 5 μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x 3.0 x.0* PFP() 00F-8-Y0 AJ μm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 50 x.6 x 3.0* PFP() 00F-8-E0 00G-8-E0 AJ0-837 for ID: mm Synergi.5 µm igh Speed Technology (ST) Columns (mm) Phases 50 x.0 00 x.0 ydro-rp 00B-387-B0 00D-387-B0 Polar-RP 00B-37-B0 00D-37-B0 Fusion-RP 00B-3-B0 00D-3-B0 µm Narrow Bore Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x x 3.0 x.0* ydro-rp 00F-375-Y0 00G-375-Y0 AJ0-750 Polar-RP 00F-336-Y0 00G-336-Y0 AJ Fusion-RP 00F--Y0 00G--Y0 AJ µm Minibore Columns (mm) SecurityGuard Cartridges (mm) Phases 30 x.0 50 x.0 75 x.0 50 x.0 x.0* ydro-rp 00A-375-B0 00B-375-B0 00C-375-B0 00F-375-B0 AJ0-750 Polar-RP 00A-336-B0 00B-336-B0 00C-336-B0 00F-336-B0 AJ Fusion-RP 00A--B0 00B--B0 00C--B0 00F--B0 AJ If Gemini, Luna, and Synergi analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase, and dimensions, send in your comparative data within 5 days and keep the Luna column for FREE. µm Analytical Columns (mm) SecurityGuard Cartridges (mm) Phases 50 x.6 75 x.6 50 x.6 50 x.6 x 3.0* ydro-rp 00B-375-E0 00C-375-E0 00F-375-E0 00G-375-E0 AJ0-75 Polar-RP 00B-336-E0 00C-336-E0 00F-336-E0 00G-336-E0 AJ Fusion-RP 00B--E0 00C--E0 00F--E0 00G--E0 AJ for ID: mm *SecurityGuard Analytical cartridges require holder, Part No.: KJ0-8 Additional analytical and preparative dimensions available. Contact us or visit Protect Your PLC Column SecurityGuard Cartridge System Extends your PLC column lifetime Won t alter your chromatography Compatible with virtually all PLC columns To learn more about protecting your PLC column investment visit Australia t: f: auinfo@phenomenex.com Canada (800) (30) info@phenomenex.com Germany anfrage@phenomenex.com Luxembourg +3 (0) (0) nlinfo@phenomenex.com Puerto Rico (800) 5-PLC (30) info@phenomenex.com Austria t: f: anfrage@phenomenex.com Denmark dkinfo@phenomenex.com Ireland eireinfo@phenomenex.com Netherlands nlinfo@phenomenex.com United Kingdom ukinfo@phenomenex.com Belgium t: +3 (0) f: +3 (0) beinfo@phenomenex.com France franceinfo@phenomenex.com Italy italiainfo@phenomenex.com New Zealand nzinfo@phenomenex.com All other countries: Corporate Office USA (30) (30) info@phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR _I 8
Gemini-NX Performance paired with Axia Technology
Si Si Si Si Si Si Si C Si Si Si Si Si Gemini-NX Performance paired with Axia Technology Gemini -NX Axia Packed Technology Improves Yield, Throughput, and Column Lifetime Ideal Purification Platform While
More informationThe Standard for ph Method Development
The Standard for ph Method Development High Efficiency Excellent Lifetime ph Stable - www.phenomenex.com/gemini U.S. Patent No.,, Setting the Standard for ph Method Development Gemini columns are rugged
More informationAGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography
Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low
More informationAPPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)
T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming
More informationAPPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction
Peptide Purification Method Development: Application for the Purification of Bivalirudin Marc Jacob, Joshua Heng, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA In this technical
More informationAPPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)
T-147 APPLICATIS Alternative Selectivity of Chiral Stationary Phases Based on Cellulose tris(3-chloro-4-methylphenylcarbamate) and Cellulose tris(3,5-dimethylphenylcarbamate) Liming Peng, Tivadar Farkas
More informationQuick and Simple Cleanup for. Medicinal Chemistry. It s BIG.
Quick and Simple Cleanup for Medicinal It s IG. Guaranteed Cleanup of Post Synthesis Reactions Strata -XL Giga s are designed to make Medicinal easy! With Strata Giga tubes I ve been able to purify a compound
More informationAPPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12
APPLICATIONS Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12 in Dietary Supplements by LC/MS/MS using Synergi Fusion-RP Column Xianrong (Jenny Wei Senior Scientist PhenoLogix applications
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More information35 % OFF HPLC. The Ultimate Guide to
The Ultimate Guide to HPLC Reversed Phase Selectivity 5 % FF Your Perfect Column Expires: 0 November 0 Promo Code: RPNV *ffer applies to products listed in this brochure and for columns with ID less than
More informationmau 200 ph min
mau ph - 6 8 TAKE A LOOK INSIDE TWIN Technology TWIN (Two-In-One ) Technology is what gives Gei its superior performance edge. During the final stage of silica manufacturing, a unique silica-organic layer
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationAnalysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes
Priority Analysis LC GC Core-Shell Technology GC Columns Kinetex PAH Expanded resolution with chemical selectivity specifically for PAHs Increased throughput and sensitivity with core-shell technology
More informationAPPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS
Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS Xianrong (Jenny) Wei Senior Scientist Jenny is a Senior Scientist in Phenomenex
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 56, 67 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible,
More informationsynergi Ultra-Performance HPLC The Concept Behind Synergi: Separate the Entire Polarity Spectrum Material Characteristics
Ultra-Performance HPLC Columns The Concept Behind : Separate the Entire Spectrum Much like a carpenter needs a good set of tools, we envisioned analytical chemists would appreciate a unique set of chromatography
More informationGemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More information( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k
Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry,
More informationThermo Scientific Accucore XL HPLC Columns. Technical Manual
Thermo Scientific Accucore XL HPLC Columns Technical Manual Thermo Scientific Accucore XL HPLC Columns Based on Core Enhanced Technology using µm solid core particles, Accucore XL HPLC columns allow users
More informationUltra-Performance LC Columns SM
Still seeing peak tailing on your C8? Ultra-Performance LC Columns SM Is resolving polar compounds difficult? Having trouble with metabolite retention? High Selectivity Low Selectivity COLUMN SELECTION
More informationLeave Your Footprint!
Leave Your Footprint! Luna HILIC Luna HILIC columns retain a water-enriched layer on the surface of the silica. This water layer facilitates the transfer of polar compounds into the stationary phase for
More informationEnhance Resolution FOR POLYMER ANALYSIS, Guaranteed *
Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed * Remarkable Reproducibility Exceptional Efficiency Long Lifetimes Economically Priced www.phenomenex.com/phenogel Phenogel Non-Aqueous GPC/SEC Columns
More informationzorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax
Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column
More information[ Care and Use Manual ]
Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationAutomating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents
Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents Marco Karsten, Bas, Dolman, Giovanni Maio, Frank Steiner, Holger Franz, Frank Arnold and Remco Swart LC Packings,
More informationProduct Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns
Product Bulletin HPLC Columns ACE LC/MS and Rapid Analysis HPLC Columns 0 mm, 30 mm, 35 mm and 50 mm column lengths.0,., 3.0, 4.0 and 4.6 mm column diameters Configured for High Sample Throughput Specially
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationviridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis
[ viridis columns ] viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC)
More informationANALYSIS OF BASIC COMPOUNDS
COMPARISON OF Fully AND Superficially POROUS PARTICLE COLUMNS FOR THE ANALYSIS OF BASIC COMPOUNDS Kenneth J. Fountain, Jane Xu, Zhe Yin, Pamela C. Iraneta, Diane M. Diehl Waters Corporation GOAL Compare
More informationFluophase and Fluofix Columns
TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for
More informationKromasil Eternity Designed for long life. For use in HPLC and UHPLC
Kromasil Eternity Designed for long life For use in HPLC and UHPLC The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development. That s
More informationOptimizing GC Parameters for Faster Separations with Conventional Instrumentation
Optimizing GC Parameters for Faster Separations with Conventional Instrumentation Anila I. Khan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 243 Key Words TraceGOLD fast GC analysis
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationHydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity
Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20544 Key Words Hydrophilic, HILIC,
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationFast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns
Application Note 3 Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns INTRODUCTION Polymeric monolithic stationary phases offer an alternative to the classical microparticulate
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationMethod Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationFluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.restek.com/raptor The Raptor luorophenyl Column With Raptor
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationFluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated
Get the Power of HILIC and RP Modes in One LC Column Selectivity Accelerated Stationary Phase: luorophenyl CH 3 Si CH 3 O Pure Chromatography www.bgb-shop.com/raptor The Raptor luorophenyl Column With
More information1.7µm Fortis C18 UHPLC Columns
Strength in Technology.7µm Fortis C8 Columns Ultra High Pressure Chromatography Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Wider Linear flow rate range .7µm Columns - 8m/g
More informationAnalysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns
Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 2 PFP Columns Application ote Small Molecule Pharmaceuticals Authors Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd Linhai Zhang
More informationLC Technical Information
LC Technical Information Method Transfer to Accucore.6 μm Columns Containing solid core particles, which are engineered to a diameter of.6μm and a very narrow particle size distribution; Accucore HPLC
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationKromasil Eternity Designed for long life
Kromasil Eternity Designed for long life For use in HPLC and UHPLC Kromasil The long-lasting phase for demanding applications Imagine working under virtually no ph restrictions during method development.
More informationFast, Accurate Environmental Testing
GC Columns Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring Pesticides Diesel Range Organics Semivolatiles Dioxane And more.. www.phenomenex.com/environmental Semi-Volatile Organic
More informationPhenogelTM Non-Aqueous GPC/SEC Columns
PhenogelTM Non-Aqueous GPC/SEC Columns Improve Resolution Wide solvent compatibility Temperature stability up to 140 C Narrow bore columns available for reduced solvent consumption Phenogel GPC Materials
More informationRP C18 column with feature of a silanol group
RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise
More informationACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC
ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm, µm and
More informationHILIC Method Development in a Few Simple Steps
HILIC Method Development in a Few Simple Steps Monica Dolci, Luisa Pereira, Dafydd Milton and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Overview This poster presents a systematic approach
More informationColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns
ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH
More informationEpic Aromatic Selectivity
Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationComparison of different aqueous mobile phase HPLC techniques
June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active
More informationIt s hot! ZIC -chilic
It s hot! ZIC -chilic Complementary selectivity for HPLC and LC-MS separation of polar hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany ZIC -chilic Your benefits
More informationcolumns IonPac SCS 1 Silica Cation Separator
columns IonPac SCS Silica Cation Separator The SCS Silica Cation Separator is designed for use with nonsuppressed conductivity detection, or single-column ion chromatography (SCIC). This column is particularly
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationDilution(*) Chromatography
WA20264 Poster # 184, HPLC 2002, Montreal, 4-5 June 2002 At-Column Column-Dilution for Preparative Dilution(*) Chromatography Cecilia Mazza, Jie Cavanaugh, Ziling Lu,Tom Sirard,Tom Wheat and Uwe Neue Waters
More informationDetermination of Verapamil Hydrochloride Purity Using the Acclaim PA Column
Application Note 95 Determination of Hydrochloride Purity Using the Acclaim PA Column INTRODUCTION -based medications are prescribed for several heart and blood pressure indications. The fastacting formulations
More informationInertSustainSwift C8
HPLC, LC/MS Columns InertSustainSwift TM C8 New! InertSustainSwift C8 is an octyl group (C8) bonded column offering the same extreme inertness to any type of compounds just like InertSustainSwift C8, which
More informationLC-MS/MS Method for the Determination of Diclofenac in Human Plasma
LC-MS/MS Method for the Determination of Diclofenac in Human Plasma J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20569 Key Words SPE, SOLA, Accucore RP-MS, diclofenac, Core
More informationSHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.
SIELC Technologies, Inc. 65 E. Palatine Rd., Suite Prospect eights, IL 60070 P. 87-9-69 F. 87-655-6079 mail@sielc.com www.sielc.com SARC Separation separation Technology LC Column with ydrogen Bonding
More informationAn HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint
An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint An important new column in the Inertsil series Bonded-Phase Structure Perfect balance of retention for both polar
More informationGeneral Principles of HPLC Method Development
General Principles of PLC Method Development Philip J. Koerner, Ph.D. Thailand September 213 Part 1. General Chromatographic Theory Part 2. The Stationary Phase: An verview of PLC Media Part 3. Role of
More informationSTUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS
STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS Fang Xia, Jie Y. Cavanaugh, Uwe Neue, Jeffrey R. Mazzeo, Diane M. Diehl Waters Corporation, Milford, MA USA OVERVIEW- INTRODUCTION-
More informationACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE Excel SuperC8 TM Ultra-Inert UHPLC and HPLC s with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS-compatible buffers between ph.. High efficiency µm, µm,
More informationZirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions
Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under on-extreme Mobile Phase Conditions Richard A. Henry, Shawn R. Wyatt, Carmen T. Santasania and David S. Bell
More information4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.
Increase Throughput and Recoveries for EPA Method 508.1 with Automated Extraction using Strata C18-E SPE Cartridges and Zebron ZB-MultiResidue GC Columns Kali Tudela Phenomenex, Inc., 411 Madrid Ave.,
More informationSHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.
SIELC Technologies, Inc. 65 E. Palatine Rd., Suite Prospect eights, IL 60070 P. 87-9-69 F. 87-655-6079 mail@sielc.com www.sielc.com SARC Separation separation Technology LC Column with ydrogen Bonding
More informationUPLC Method Development and Validation
UPLC Method Development and Validation Rev. 2 2008 Waters Corporation Challenges of Method Development Methods are developed throughout the drug development process Samples vary in complexity Redundancy
More informationAnalysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF
application Note Liquid Chromatography/ Mass Spectrometry Author Sharanya Reddy PerkinElmer, Inc. Shelton, CT USA Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF
More informationKromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography
Kromasil for your analytical HPLC Kromasil The way to peak performance in liquid chromatography Kromasil is known, worldwide, for its high performance and excellent total economy in preparative and industrial
More informationThe World s Leading. One of. HPLC Columns
One of The World s Leading HPLC Columns Phenomenex India Laxmi Cyber City, Ground Floor, B Block, Survey no: 0 Kondapur, Hyderabad 00 08, India Tel: 00-0 00 Fax: 00-0 Email: indiainfo@phenomenex.com Web:
More informationA Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone
A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone Mia Summers and Kenneth J. Fountain Waters Corporation, 34 Maple St.,
More informationN α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)
A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary
More informationChromegaChiral TM CSP Media and Columns
ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More informationUSP 3, 5, 10, 10- PREP
ne of the World s Leading HPLC Columns Develop or Improve your HPLC Method Exceptionally rugged USP phases Easy method scalability with,,, -PREP and μm media Extensive batch traceability and reproducibility
More informationExceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens
Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-exyl Columns to Separate Estrogens Application Note Pharmaceutical, Environmental Authors John W. enderson Jr. and William J. Long Agilent
More informationCarbon Load % Calculated Bonded Phase Coverage (µmole/m 2 ) Surface Area (m 2 /g)
ne of the World s Leading HPLC Columns Develop or Improve your HPLC Method Exceptionally rugged USP phases Easy method scalability with,,, -PREP and μm medias Extensive batch traceability and reproducibility
More information3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity
Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which
More informationNext Generation of Phenyl Columns. Chromatography Products.
Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both
More information1.7 m Fortis UHPLC Columns
Strength in Technology 1.7 m Fortis Columns Ultra High Pressure Chromatography Improve your Performance 8 Chemistry Choices Increase Efficiency Increase Speed Improve Resolution Greater Sensitivity Lower
More informationACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability
ACE SuperC8 TM Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability Exploit selectivity at low, intermediate and high ph Use with LC/MS compatible buffers between ph.. High efficiency µm, µm,
More informationIN QUALITATIVE ANALYSIS,
IN QUALITATIVE ANALYSIS, YOU VE ALWAYS HAD TO CHOOSE BETWEEN ACCURACY AND THROUGHPUT. NOW THERE S NO REASON TO ever have to. WATERS QUALITATIVE ANALYSIS solutions Waters ACQUITY UPLC System with the Waters
More informationDefinitive EtG/EtS LC-MS/MS Analysis:
Definitive / LC- Analysis: A Rugged 4-Min Method for High-Throughput Labs By Justin Steimling and Frances Carroll Abstract Methods for monitoring alcohol consumption biomarkers and are generally limited
More informationMethod Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples
Technical Note 101 Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples This technical note includes by specific information on the extraction
More informationThermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time
Thermo Scientific Syncronis HPLC Columns Remarkable separations guaranteed time after time Syncronis HPLC and UHPLC Columns Remarkable separations guaranteed time after time When developing a new method,
More informationHydrophilic Interaction Liquid Chromatography: Method Development Approaches
Hydrophilic Interaction Liquid Chromatography: Method Development Approaches Monica Dolci, Luisa Pereira, and Tony Edge Thermo Fisher Scientific, Runcorn, Cheshire, UK Abstract This poster summarizes the
More informationDionex IonPac AS28-Fast-4µm column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS-Fast-4µm Columns Product Specifications The Thermo Scientific Dionex IonPac AS-Fast-4µm column is a high-capacity, hydroxide-selective anionexchange column
More informationThermo Scientific. Anion-Exchange Column
CHROMATOGRAPHY Thermo Scientific Dionex IonPac AS9-µm Anion-Exchange Column Product Specifications The Themo Scientific Dionex IonPac AS9-µm high-capacity, hydroxide-selective, anion-exchange column is
More informationHigh Performance Liquid Chromatography
High Performance Liquid Chromatography What is HPLC? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube packed with a tiny particles (stationary phase).
More informationPhenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns Alternate, complementary selectivity to C8 and C8 bonded phases Particularly recommended for compounds containing aromatic groups Excellent bonded phase stability for durable,
More informationA Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS
A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS Jason Lai, Jia Wang, Brad Hart, Pavel Aronov, Kristine Van Natta, Marta Kozak, Jorge Valdivia, Andy Jacobs, Haibo
More informationChromegaChiral TM CSP Media and Columns
ChromegaChiral TM CSP Media and Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More information