Analgesics / Cough 1 & Cold Medicine Ingredients
|
|
- Julie Woods
- 5 years ago
- Views:
Transcription
1 Analgesics / Cough & Cold Medicine Ingredients mau H. paracetamol H CH H H. -aobenzoic acid H H H C CH. -hydroxybenzoic acid 7 CH H CH. caffeine 8 9 H. -acetamidophenol 0 H H. -hydroxybenzoic acid H C8-AR 7. salicylamide H H H C 0. aspirin CH H H H 8. acetanilide H H C. salicylic acid C H. benzoic acid H H H 9. phenol H CH H. sorbic acid. phenacetin,, ,, C8. salicylaldehyde 0x.mm, mm Gradient analysis A = 0.% v/v formic acid (aq) B = 0.% v/v formic acid in MeC 0C 0nm.0mL/ T () %B 0 9
2 Pharmaceutically Relevant Mixture UltraCore SuperC8: selectivity with ph: 8,9 7 0 ph 0x.mm,.mm Gradient analysis A= 0mM HCH, ph (aq) B= 0mM HCH, ph in MeC/water 9: v/v A= 0.% H, ph 0.7 (aq) B= 0.% H, ph0.7 in in MeC/water 9: v/v T %B DAD C, Sig=,8 Ref=0,00 (F:\0-MJ\0_LW_PH \LW D) DAD C, Sig=,8 Ref=0,00 (F:\0-MJ\ \HIGH D) 0 ph 0.7 0C 0.0 ml/ nm. Atenolol. Methylphenylsulfoxide. Eserine. Prilocaine. Bupivacaine. Tetracaine 7.,,,-Tetrahydro--naphthol 8. Carvedilol 9. itrobenzene 0. Methdilazine. Amitriptyline. Valerophenone
3 Paraben Preservatives Phenyl, 0 x.mm Isocratic Methanol mm H Ac (0:0), ph.8 Flow rate: 0.ml/ Column temperature: 0 C Detection: UV at 0nm Sample volume: μl. Methylparaben. Ethylparaben. n-propylparaben. i-butylparaben. -Butylparaben. Benzylparaben Reproduced with permission of Trevor Gibson, The Chemical Analysis Facility, University of Reading
4 Pharmaceutically Relevant mixture Separation UltraCore SuperPhenylHexyl: selectivity with ph: 9,,8 ph 0x.mm,.mm Gradient analysis A= 0mM HCH, ph (aq) B= 0mM HCH, ph in MeH/water 9: v/v 0 A= 0.% H, ph 0.7 (aq) B= 0.% H, ph0.7 in in MeH/water 9: v/v 7 T %B C 0.0 ml/ nm 0 78 ph Benzamide. Caffeine. Procainamide. -acetylprocainamide. Propiophenone. Toluene 7. Remacemide 8. Ethylbenzene 9. Carvdilol 0. ortriptyline. Clomiprae
5 Clonidine Hydrochloride Clonidine hydrochloride oral solution containing preservatives Concentration clonidine HCl = 0μg/ml Concentration Preservatives ~.g/ml. Clonidine hydrochloride. Methyl hydroxybenzoate. Propyl hydroxybenzoate UltraCore SuperC8.μm, 0 x.mm Gradient analysis A = 0.% w/v phosphate buffer-ch H- CH C (80:0:0) B = CH C Time (s) %B Flow rate: ml/ Column temperature: 0 C Injection volume: 00μl Detection: UV, 0nm Reproduced with permission of Mary guyen, Guys Hospital, London
6 Procaine and p-aobenzoic acid p-aobenzoic acid (potential degradant) Procaine Procaine sterile manufactured product System suitability tests C8-PFP μm, 00 x.mm Isocratic analysis Methanol - 0.% acetic acid (9:8) (adjusted to ph.7 with 0% ah) Flow rate: ml/ Detection: UV, 79nm Detection limits for S/ = 0 Procaine = 0.000mg/ml p-aobenzoic acid = mg/ml Reproduced with permission of John Peace, Huddersfield Royal Infirmary, UK
7 mau Water Soluble Vitas C8-AR 00 H H H H C Pyridoxine (vita B) CH Pantothenic acid (vita B) H H H CH H H H p-aobenzoic acid H Folic acid (vita B9 or vita M) H H D-Biotin (vita B7 or vita H) H H H H H H H H S H H C H C H Cyanocobala (vita B) H Riboflavin (vita B) 0x.mm, mm Gradient analysis A = 0mM KH P, ph.8 (aq) B = 0mM KH P, ph.8 in : v/v MeH:water 0C 0nm.mL/ T () %B H 7 H H. Pyridoxine (vita B). Pantothenic acid (vita B). p-aobenzoic acid. Folic acid (vita B9 or vita M). D-Biotin (vita B7 or vita H). Cyanocobala (vita B) 7. Riboflavin (vita B)
8 mau C8-AR Water Soluble Vitas / Polar Molecules Isonicotinamide H C H H + S H C Thiae or vita B H icotinamide H H H H H 7 H L-Ascorbic acid or vita C H H Hypoxanthine H H H rotic acid 0 H um, 0 x. mm Isocratic analysis Flow rate:.0 ml/ Temperature: C Detection: UV 0 nm MP: 9.:. v/v 0.% HP (aq) : MeH 8 8 H -aobenzoic acid H H C Pyridoxal or H Pyridoxae or Vita B H CH H vita B 9 H H H Pyridoxine or vita B CH H 0 8
9 C8-AR on-steroidal Anti-Inflammatory Drugs CH H 9 mau Ketoprofen H C aproxen CH H Indomethacin Cl 0x.mm, mm Gradient analysis A = 0.% v/ formic acid (aq) B = 0.% v/v formic acid in MeH 0C.0mL/ nm T () %B H F F F H H C Sulindac CH S CH Ibuprofen HCl CH Cl Diclofenac Cl H H CH H C 7 H 8 H C 9 Cl Meclofenamic acid H Cl Mefenamic acid CH H C H H H * H S Bendromethazide S H H C CH H
10 Complex Steroid Mixture Separation 0 C8-AR
11 C8-PFP : Halogenated Positional Isomers Chloroacetophenone halogenated isomers separation
12 Polar Analytes ucleosides & Vitas 00% Aqueous H C H + S H C Thiae or vita B H icotinamide H H H H H H L-Ascorbic acid or vita C C8-PFP, um, 0 x. mm Isocratic analysis Flow rate: ml/ Temperature: C Detection: UV nm Cytosine H Uracil H Mobile phase: 0 mm H P (aq) H H H Cytidine H Pyridoxae or Vita B H H CH H H H 7 8 H H Hypoxanthine 9 -Deoxycytidine H H H
13 Separation of Sulphonamides Excel C8-PFP μm, 0 x.mm Gradient analysis A = Water B = Acetonitrile C = 0% formic acid Time (s) %A %B %C Flow rate: ml/ Detection: UV, nm. Sulfadiazine. Sulfapyridine. Sulfamerazine. Sulfamoxole. Sulfamethazine. Sulfamonomethoxine 7. Sulfachloropyridazine 8. Sulfamethoxazole 9. Sulfadimethoxine Reproduced with permission of Antonio Martin Esteban, ational Research Institute of Agriculture and Food Technology IIA, Spain
14 Aspirin And Related Substances Excel C-ES Alternative selectivity with MeH containing eluents H H H H C H CH CH H H H C H CH H H C-ES 0x.mm, mm Gradient analysis Excel C A = 0.% formic acid B = 0.% FA in MeH 0 C 0. ml/ 0 nm 8% B in.7 s Hold at 8% B until s Excel C ,. -Acetamidophenol. Acetanilide. Salicylamide. Aspirin. Phenacetin. Salicylic acid
15 Small Pharmaceutically Relevant Analytes Excel C-ES Dipole + hydrophobic Interactions C-ES 00xmm, mm Gradient analysis Excel C8-Amide /.00 Polar embedded + hydrophobic Interactions A = 0mM ammonium formate (aq) B = 0mM ammonium formate in MeH 0C 0. ml/ T () %B Excel C8-PFP /.09 Hydrophobic + π-π + dipole + shape / position Interactions Hydrochlorothiazide. Methylphenylsulphoxide.,, Trinitrobenzene. Myricetin. P-Cresol. Sulindac 7. Toluene
16 Salicylic acid in cell extracts Extract from genetically engineered bacteria cells targeted analysis for salicylic acid UltraCore SuperC8, μm, 0 x.mm Gradient analysis (shown above) A = 0.% TFA in water B = 0.% TFA in acetonitrile Flow rate: ml/ Detection: UV, 0nm Reproduced with permission of Trong Khoa Pham, University of Sheffield, UK
17 USP Guaifenesin 7 Key: Guaifenesin Benzoic acid mau 0.0. UltraCore SuperC8,. μm, 0 x.0 mm Isocratic analysis H /MeH/Glacial acetic acid (0:0:. v/v) Flow rate: 0.8 ml/ Column temperature: Ambient ( C) Detection: UV at 7 nm Injection volume:. μl Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
18 USP Hydrocortisone 8 Key: Hydrocortisone Propylparaben Ultracore SuperC8,. μm, 00 x. mm Isocratic analysis MeC/MeH/H (::0 v/v) Flow rate: ml/ Column temperature: Ambient ( C) Detection: UV at nm Injection volume:.8 μl mau Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
19 USP Estradiol 9 Key: Ethylparaben Estrone Estradiol Ultracore SuperC8,. μm, 00 x. mm Isocratic analysis H /MeC (: v/v) Flow rate:.9 ml/ Column temperature: Ambient ( C) Detection: UV at 0 nm Injection volume: 0. μl mau Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
20 USP 7a-Ethinylestradiol 0 Key: Ethylparaben 7α-Ethinylestradiol Ultracore SuperC8,. μm, 0 x.0 mm Isocratic analysis MeC/H (0:0 v/v) Flow rate: 0. ml/ Column temperature: Ambient ( C) Detection: UV at 80 nm Injection volume:. μl mau Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
21 USP aproxen Key: aproxen Butyrophenone Ultracore SuperC8,. μm, 0 x.0 mm Isocratic analysis H with glacial acetic acid (9:)/MeC (0:0 v/v) Flow rate: 0. ml/ Column temperature: Ambient ( C) Detection: UV at nm Injection volume:.8 μl mau Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
22 USP Paracetamol / Aspirin / Caffeine Key: Paracetamol Caffeine Aspirin Benzoic acid Salicylic acid Ultracore SuperC8,. μm, 0 x. mm Isocratic analysis H with glacial acetic acid (9:)/MeH (7:8 v/v) Flow rate: ml/ Column temperature: C Detection: UV at 7 nm Injection volume:. μl mau Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
23 USP Hydroquinone Key: Hydroquinone Excel C8, μm, 0 x.0 mm Isocratic analysis H /MeH (: v/v) Flow rate: 0. ml/ Column temperature: Ambient ( C) Detection: UV at 80 nm Injection volume: 0.9 μl mau 0.0 H 80 H Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
24 USP Doxepin Key: Doxepin isomer Doxepin isomer mau 7. C8, μm, 0 x. mm Isocratic analysis 0. M Monobasic ah P in water ph.:meh (0:70 v/v) Flow rate: 0. ml/ Column temperature: 0 C Detection: UV at nm Injection volume:. μl 0.9 H C CH Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
25 USP Metronidazole Key: Metronidazole mau H CH.0 C8, μm, 7 x. mm Isocratic analysis H /MeH (: v/v) Flow rate.0 ml/ Column temperature: 0 C Detection: UV at 9 nm Injection volume: μl Translated method according to USP <> guidance. Always check the latest and official method information from the relevant pharmacopoeia prior to analysis.
Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster
Welcome to our E-Sear: Choosing HPLC Columns for Faster Analysis Smaller and Faster High Throughput/Fast LC Requires. Short columns 0 mm or shorter Small particle sizes. µm Rapid Resolution or new.8 µm
More informationColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns
ColumnsAcclaim PolarAdvantage II (PA) HPLC Columns A Unique and Complementary Alternative to Conventional C8.8 Column: Acclaim PA, µm Peaks: ( ppm each) Dimensions:. mm. Maleate Mobile Phase: MeOH/.% NH
More informationACE. Intelligent Solutions for Method Development. Method Development Kits ACE
r: ffe e its ric k ty mn e p i tiv olu sam mn c c u le the col e d S an for ngle le si ab s a l i a a av O ACE Method Development Kits Intelligent Solutions for Method Development UHPLC and HPLC method
More informationFast Screening Methods for Analgesics and Non-Steroidal Anti-Inflammatory Drugs by HPLC
Fast Screening Methods for Analgesics and on-steroidal Anti-Inflammatory Drugs by HPLC Application ote Small Molecule Pharmaceuticals and Generics Author William Long Agilent Technologies, Inc. Introduction
More informationReversed Phase Solvents
Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2 Solvents for RP Chromatography
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationWilliam E. Barber, Ph.D. Applications Chemist October
William E. Barber, Ph.D. Applications Chemist ctober 0 00 Secrets of Good Peak Shape in HPLC Time: :00 p.m. CET Telephone Number: + 44 0 76 088 Chairperson: John Vis The Secrets of Good Peak Shape in HPLC
More informationACE ACE. HPLC and UHPLC Columns. Product Catalogue
ACE HPLC and UHPLC Columns Product Catalogue ACE Ultra-Inert, Base Deactivated HPLC & UHPLC Columns ACE Ultra-Inert, Base Deactivated HPLC and ACE Excel UHPLC columns give you the choices you need to
More informationmau 200 ph min
mau ph - 6 8 TAKE A LOOK INSIDE TWIN Technology TWIN (Two-In-One ) Technology is what gives Gei its superior performance edge. During the final stage of silica manufacturing, a unique silica-organic layer
More informationA Look at Agilent HPLC Columns Choices
A Look at Agilent HPLC Columns Choices Brno & Prague, May 29-30 2018 Giorgio Ferlat IDO Product Specialist Chemistries and Consumable 1 Considerating Column Properties for Column Selection Silica Particle
More informationACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC
ACE C-PFP A C bonded phase with unique selectivity F F F F F Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and pentafluorophenyl mixed mode interaction High efficiency µm, µm,
More informationPrimesep TM. Solving Problems of Pharmaceutical HPLC Analysis. Creating New Dimensions in the World of Chromatography.
Primesep TM Solving Problems of Pharmaceutical HPLC Analysis Creating ew Dimensions in the World of Chromatography www.primesep.com Content Introduction ovel stationary phase properties Retention of polar
More informationHigh Resolution Fast LC
High Resolution Fast LC Easier Than You Think Rita Steed LC Columns Application Engineer May 9, 2013 What is High Resolution Fast LC? Maintain Resolution with Faster Run Time Increased Resolution with
More informationNext Generation of Phenyl Columns. Chromatography Products.
Next Generation of Phenyl Columns Chromatography Products RESOLUTION EVOLUTION The Next Generation of Phenyl Column Chemistry The phase is the next generation of phenyl column chemistries, providing both
More informationThe Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times
The Secrets of Rapid HPLC Method Development Choosing Columns for Rapid Method Development and Short Analysis Times Rapid Analysis Is More Than Run Time It is developing a method to meet a goal and developing
More informationChoosing Columns and Conditions for the Best Peak Shape
Choosing Columns and Conditions for the Best Peak Shape What is Good Peak Shape and Why is it Important? Good peak shape can be defined as a symmetrical or gaussian peak and poor peak shape can include
More informationPRINCETON CHROMATOGRAPHY INC
ABOUT US Princeton Chromatography Inc., based in Cranbury, New Jersey, USA, was founded in 99. We have over 0 years experience in chromatography and are one of the earliest developers of novel commercial
More informationNUCLEOSHELL core-shell silica for HPLC
NUCLESHELL core-shell silica for HPLC Core-shell technology µm 0. µm.8 µm 0. µm.7 µm 0. µm.7 µm 0. µm Key feature Solid core of silicon dioxide, homogeneous shell of porous silica Highest efficiency compared
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS HALO and HALO- Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG PE, UK Tel: + (0)8 90 0 Fax: + (0)8 9 8 Email: sales@hichrom.co.uk
More informationISOSCELES PELLICULAR CORE
ISSCELES PELLICULAR CRE Isosceles Chemistry Phases Isosceles C8 USP Classification L Isosceles C8 USP Classification L7 Isosceles AQ USP Classification equivalent to L6 Isosceles Amide (ILIC) USP Classification
More informationFast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger
Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger Pittcon 2005 BINGWEN YAN 1, CLAYTON V. MCNEFF 1, 1 ZirChrom Separations, Inc., 617 Pierce Street,
More informationSunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending
Patent pending Website : www.chromtech.net.au E-mail : info@chromtech.net.au telno : 0 97 0... in AUSTRALIA A Novel Bonding Technique (patent pending) An unique trifunctional silyl-reagent was developed
More informationSolubility Prediction of Drugs in Water Polyethylene Glycol 400 Mixtures Using Jouyban Acree Model
November 2006 Chem. Pharm. Bull. 54(11) 1561 1566 (2006) 1561 Solubility Prediction of Drugs in Water Polyethylene Glycol 400 Mixtures Using Jouyban Acree Model Abolghasem JOUYBAN Faculty of Pharmacy and
More informationPerformance characteristics of the Agilent 1290 Infinity Quaternary Pump
Performance characteristics of the Agilent 129 Infinity Quaternary Pump Technical Overview Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview presents Proof
More informationApplications. Overview of applications of elevated temperature and temperature programmed liquid chromatography
Applications Overview of applications of elevated temperature and temperature programmed liquid chromatography The applications are arranged by field of interest Fundamental page 2 Pharmaceutical page
More informationLeveraging Bonded Phase Selectivity. to Achieve Better Reversed Phase HPLC Separations
Leveraging Bonded Phase Selectivity to Achieve Better Reversed Phase HPLC Separations Introduction There has been a great deal of emphasis in the past several years on column efficiency (theoretical plates,
More informationComparison of different aqueous mobile phase HPLC techniques
June 009 ewsletter Pharmaceutical Analysis: What is Your Problem? SIELC Technologies, Inc., Prospect Heights, IL 0070 Pharmaceutical analysis involves liquid chromatography of various compounds, from active
More informationCSH Technology: ACQUITY CSH Columns Applications Notebook
CS Technology: ACQUITY CS Columns Applications otebook List of compounds analyzed using csh columns Lit Code Title Page WA Acetaminophen Impurities WA Acids, Bases, and eutrals WA Aromatic Acids WA Basic
More informationPackings for HPLC. Packings for HPLC
Summary of packings for HPLC In analytical HPLC, packings with particle sizes of 3 to 10 µm are preferred. For preparative separation tasks, also particles with diameters larger than 10 µm are applied.
More informationPut the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl
Put the C18 aside and take a look... 6 Reasons to try the EW Gemini Reason #6 ALTERATE SELECTIVITY to your C18 Column Adding to your method development options, Gemini offers additional polar and aromatic
More informationAcclaim Mixed-Mode WCX-1
Acclaim Mixed-Mode WCX-1 Product Manual for the Acclaim Mixed-Mode WCX-1 Column Page 1 of 28 PRODUCT MANUAL for the Acclaim Mixed-Mode WCX-1 Columns 4.6 x 150 mm, P/N (068353) 4.6 x 250 mm, P/N (068352)
More informationAlltech Alltima HP Introduction
Alltech Introduction High-Stability, High-Purity, High-Performance, Low-Bleed Columns for Demanding Applications Better Peak Symmetry high-purity silica eliminates peak tailing problems Long Column Life
More informationBRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].
BRIEFING Propylparaben. The European Pharmacopoeia is the coordinating pharmacopeia for the international harmonization of the compendial standards for the Propylparaben monograph, as part of the process
More informationBETASIL Columns TG Å high purity silica
BETASIL Columns TG0-0 00Å high purity silica Technical Guide BETASIL Columns Introduction 00Å high purity silica High surface area and phase loading Designed for small molecules Type B silica gives good
More informationEliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput
Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput HPLC Separation Robustness and Ruggedness Group/Presentation Title June 20, Agilent 2017Month Restricted ##, 200X Page
More informationGemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationPart 2. Overview of HPLC Media
Part 1. General Chromatographic Theory Part 2. Overview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use 1 HPLC Particle Technology Core-Shell Particle Fully
More informationInertSustain AQ-C18. HPLC, LC/MS Columns. Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases
HPLC, LC/MS Columns InertSustain AQ-C8 Maximizing retention for highly polar compounds in reversed phase methods with highly aqueous mobile phases Physical Properties Silica : ES (Evolved Surface) Silica
More informationShodex TM ODP2 HP series columns
HPLC Columns Shodex TM ODP2 HP series columns Better retention of highly polar substances Technical notebook No. 6 Contents 1. Introduction 1-1. Specifications 1-2. Eluent Compatibility of ODP2 HP Series
More informationcolumns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules
columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This
More informationfor Acclaim Mixed-Mode WCX-1
for Acclaim Mixed-Mode WCX- Product Manual for the Acclaim Mixed-Mode WCX- Column Page of 8 Product Manual for Acclaim Mixed-Mode WCX- Columns Acclaim Mixed-Mode WCX-, 3µm, Analytical column, 3.0 x 50mm
More informationNew 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns
New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns have: the highest plate number versus any other 5-micron
More informationHPLC Separation Robustness and Ruggedness Assessing the Effects of Experimental Variables During Method Development
HPLC Separation Robustness and Ruggedness Assessing the Effects of Experimental Variables During Method Development Rita Steed Application Engineer Agilent Technologies, Inc. November 19, 2015 Method Development
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS penta-hilic Highly retentive, proprietary penta-hydroxy-ligand Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More informationTHE DEVELOPMENT OF LC GENERlC ANALYTICAL METHODS TO FIGHT COUNTERFEIT NSAIDS USING DESIGN SPACE OPTIMISATI0N STRATEGY
UNIVERSITY of LIEGE THE DEVELOPMENT OF LC GENERlC ANALYTICAL METHODS TO FIGHT COUNTERFEIT NSAIDS USING DESIGN SPACE OPTIMISATI0N STRATEGY J. Mbinze Kindenge, P. Lebrun, B. Debrus, A. Dispas, R.D. Marini,
More informationSetting the Standard for ph Method Development
U.S. Patent o. 7, 5, 7 Setting the Standard for ph Method Development ugged reversed phase HPLC columns that offer extended lifetime at extreme ph conditions and excellent stability for reproducible, high
More informationShabir: Simultaneous HPLC Determination of Preservatives in Gels
Research Papers A New Validated HPLC Method for the Simultaneous Determination of 2-phenoxyethanol, Methylparaben, Ethylparaben and Propylparaben in a Pharmaceutical Gel G. A. SHABIR* xford Brookes University,
More informationHPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE.
HPLC COLUMNS VARIAN, INC. XRs Pursuit E X tr a Resolution. Ma ximum Life time. Ultimate Performance. The new standard in HPLC Designed to deliver ultimate performance in the most demanding laboratories,
More informationSHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.
SIELC Technologies, Inc. 65 E. Palatine Rd., Suite Prospect eights, IL 60070 P. 87-9-69 F. 87-655-6079 mail@sielc.com www.sielc.com SARC Separation separation Technology LC Column with ydrogen Bonding
More informationOptimisil HPLC & UPLC Column catalogue
Optimisil HPLC & UPLC Column catalogue Analytical Hub Plot No: 37, P & T Colony, Vikrampuri, Secunderabad 500009 Tel: 040-64621313, Mobile: +91 7799931313 Website: www.analyticalhub.com email: contact@analyticalhub.com
More informationApplication Note. Food. Abstract. Author
Selective Analysis of on-utritive Food Additives Using Agilent ZRBAX Eclipse Plus C, Eclipse Plus Phenyl-Hexyl, Eclipse XDB-Phenyl, and StableBond SB-Phenyl Columns Application ote Food Author Anne E.
More informationHICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies LC COLUMNS SIELC Primesep Catalogue 9 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)8 90 660 Fax: +44 (0)8 9 484 Email: sales@hichrom.co.uk
More informationToo Polar for Reversed Phase What Do You Do?
Too Polar for Reversed Phase What Do You Do? June 20, 2013 Mark Powell Columns and Consumables Technical Support Page 1 C8 or C18 Doesn t Always Do the Job Typical reversed phase conditions involve water/buffer
More informationZirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS EAS 2005 Bingwen Yan 1, Clayton V. McNeff 1, Richard A. Henry 2, and David S. Bell 2 1 ZirChrom Separations, Inc., 617 Pierce Street, Anoka,
More informationAnalysis - HPLC A.136. Primesep 5 µm columns B.136
Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using
More informationState-of-the-art C18 HPLC Columns
An HPLC GL Sciences Newest and Most Advanced ODS Phase-New For 00 State-of-the-art C HPLC s Improved Peak Shapes and Heights Enhancing Sensitivity High Resolution Fast Equilibration Compatible with 00%
More informationEpic Aromatic Selectivity
Epic Aromatic Selectivity HPLC Columns p h a r m a c e u t i c a l e n v i r o n m e n t a l c h e m i c a l b i o c h e m i c a l s e p a r a t i o n & p u r i f i c a t i o n ES Industries 701 S. Route
More informationSIMULTANEOUS ESTIMATION OF MEFENAMIC ACID AND PARACETAMOL IN SUSPENSION FORM BY USING UPLC
Int. J. Chem. Sci.: 12(3), 214, 115-122 ISSN 972-768X www.sadgurupublications.com SIMULTANEOUS ESTIMATION OF MEFENAMIC ACID AND PARACETAMOL IN SUSPENSION FORM BY USING UPLC D. MAHABOOB BASHA and K. ANANDA
More informationCHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data
Introduction The enrichment of hydrophilic analytes from polar matrices is a challenge because they often cannot be retained by C 18 / C 8 -modified silica or hydrophobic polymer adsorbents. To overcome
More informationSilanol. Groups Liquid Chromatography
Abstract umber: 0-8P Study of Secondary Interaction Based on Residual lanol Groups for Reversed-Phase Liquid Chromatography II orikazu agae Ph.D, Kouji Yamamoto, Chiaki Kadota Chromaik Technologies Inc.
More informationSHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.
SIELC Technologies, Inc. 65 E. Palatine Rd., Suite Prospect eights, IL 60070 P. 87-9-69 F. 87-655-6079 mail@sielc.com www.sielc.com SARC Separation separation Technology LC Column with ydrogen Bonding
More informationMulti-mode Separations Using Zirconiabased Stationary Phases
Multi-mode Separations Using Zirconiabased Stationary Phases PITTC 2010 Dan owlan 1, Bingwen Yan 1, Clayton V. Mceff 1, R.A. Henry 2 1 ZirChrom Separations, Inc. 617 Pierce St., Anoka, M 55303 2 Independent
More informationSTUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS
STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS Fang Xia, Jie Y. Cavanaugh, Uwe Neue, Jeffrey R. Mazzeo, Diane M. Diehl Waters Corporation, Milford, MA USA OVERVIEW- INTRODUCTION-
More informationultimate efficiency unleashed [ Cortecs 1.6 µm columns ]
ultimate efficiency unleashed [ Cortecs columns ] [ CORTECS UPLC COLUMNS ] A SUB--µm SOLID-CORE PARTICLE COLUMN THAT LIVES UP TO ITS POTENTIAL. C 8 + C 8 HILIC SOLID-CORE PARTICLE COLUMNS THAT DELIVER
More informationThermo Scientific Hypersil GOLD HPLC Columns
Technical Manual Thermo Scientific Hypersil GOLD HPLC Columns Outstanding peak shape for your separations Thermo Scientific Hypersil GOLD Columns Designed for improved chromatography, Thermo Scientific
More informationHigh Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>
High Performance Liquid Chromatography HPLC-9 Ultra-high Speed Analysis of Ibuprofen within USP Allowed Limits by Nexera Method Scouting In recent years, high-throughput analytical techniques have
More informationDissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.
Atorvastatin Calcium Tablets Type of Posting Posting Date 25 Jan 2019 Official Date 01 Feb 2019 Expert Committee Chemical Medicines Monographs 2 Reason for Revision Compliance In accordance with the Rules
More informationOverview Applications of NUCLEODUR HPLC Phases
verview Applications of HPLC Phases Phase Specification Characteristics* Stability Structure A B C octadecyl phase, high density coating multi-endcapping 8% C USP L ph stability -, suitable for LC/MS (Si-
More informationRP C18 column with feature of a silanol group
RP C8 column with feature of a silanol group lanol Activity Controlled C8 Column Sunrise ctacosyl C8) Sunrise ctadecyl C8) Sunrise ctadecyl-sac C8-SAC has an interaction of silanol groups ChromaNik Sunrise
More informationFluophase and Fluofix Columns
TG 0-0 Fluophase and Columns Introduction Fluorinated packings exhibit extra retention and selectivity for compounds that have fluorine and chlorine substituents. They also exhibit shape selectivity for
More informationHPLC column. Sunniest. C18, C18-HT, RP-AQUA, C8, PhE, PFP. ChromaNik Technologies Inc.
HPLC column Sunniest C8, C8-HT, RP-AQUA, C8, PhE, PFP Chromaik Technologies Inc. A ovel Bonding Technique (patent pending) The State of Art trifunctional silyl-reagent was developed as shown in Fig.. This
More informationPerformance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography
Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography Technical Overview 2D-LC Conventional 1D-LC Abstract This Technical Overview presents
More informationA C18 Silica Column With Exceptional Temperature and ph Stability
A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies,
More informationH P L C C O L U M N S
H P L C C O L U M N S New, HxSil TM C8 and C8 HPLC Columns A Word about HPLC Columns For over 0 years Hamilton HPLC columns have been solving problems no other columns could. Now we have introduced HxSil
More informationA Unique, New, Multipurpose Sorbent Engineered for Reversed-Phase SPE
Poster #151 ISC '96 21st International Symposium on Chromatography, Stuttgart, September 15th-20th, 1996 1 A Unique, ew, Multipurpose Sorbent Engineered for Reversed-Phase SPE Authors 2 McDonald, P.D.*,
More informationAcclaim HPLC and UHPLC Columns
Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical,
More informationRapid and simultaneous determination of paracetamol, ibuprofen and related impurity of ibuprofen by UPLC/DAD
Pharmaceutical Sciences Asia Pharm Sci Asia 2018; 45 (4), 213-220 Research Article DOI :10.29090/psa.2018.04.017.0056 Rapid and simultaneous determination of paracetamol, ibuprofen and related impurity
More informationNovel LC/MS-Compatible Stationary Phase with Polar Selectivity
Novel LC/MS-Compatible Stationary Phase with Polar Selectivity Carmen T. Santasania and David S. Bell Supelco 595 N. Harrison Rd., Bellefonte, PA 16823 T403168 GJU Introduction Stationary phases based
More informationInertsil ODS-EP Technical Information
Technical Information Advantages of The selectivity is completely different from those of conventional columns such as ODS column due to its specific polar group in the stationary phase. Durability can
More informationFast Separation of Vastly Different Compounds by Isocratic HPLC
Fast Separation of Vastly Different Compounds by Isocratic HPLC Aimee N. Heyrman and Yury Zelechonok Resolution Systems, Inc. 590 E. 32nd St. Holland. MI, 49423 SIELC Technologies, 15 E. Palatine Rd, Suite
More informationINERTSIL (GL Sciences)
Inertsil 3 Series The Inertsil 3 series from GL Sciencesʼ represents a major advance in performance over the original Inertsil 2 Series. Inertsil 3 Series phases are based on a purer, higher surface area
More informationValidated HPLC Methods
Validated HPLC Methods To Tweak or Not to Tweak Slide 4 Adjustments of operating conditions to meet system suitability requirements may be necessary. USP 23 p1776 Slide 5 001816S1.PPT What is the line
More informationMethod Development Kits
Method Development Kits sales representative for ordering information or contact...77 Method Development Kits First column choice for Pharma Development USP L C Method Development Kits Maximize retention
More informationLC and LC/MS Column Selection Flow Chart
LC and LC/MS Column Selection Flow Chart To use the column selection diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the
More informationDo you need trouble-free speed? The NEW Chromolith HR
Do you need trouble-free speed? The NEW Chromolith HR EMD Millipore is a division of Merck KGaA, Darmstadt, Germany ... then speed-up to Chromolith HighResolution... Revolutionary monolithic silica columns
More informationHPLC Method Development: Standard Practices and New Columns
HPLC Method Development: Standard Practices and New Columns Edward Kim Application Engineer Agilent Technologies, Inc. March 8, 29 What are Some Standard Method Development Practices?. Follow preferred
More informationAnalyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column
pharmaceutical #9 Applications note Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column Mixtures of nucleotides, nucleosides, and their respective purine
More informationpenta-hilic UHPLC COLUMNS
penta-hilic UHPLC COLUMNS Highly retentive, proprietary penta-hydroxy-ligand penta-hilic Excellent peak shape for polar compounds with a variety of functional groups: acids, bases, zwitterions strong and
More information(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted
Hydrophilic Interaction Chromatography (HILIC) Bill Champion Agilent Technologies, Inc. 800-227-9770 opt 3/opt3/opt 2 william_champion@agilent.com Page 1 HILIC A method of recent attention Bill Champion
More informationHPLC Determination of Antidepressants and their Metabolites in Plasma
HPLC Determination of Antidepressants and their Metabolites in Plasma
More informationUSP 3, 5, 10, 10- PREP
ne of the World s Leading HPLC Columns Develop or Improve your HPLC Method Exceptionally rugged USP phases Easy method scalability with,,, -PREP and μm media Extensive batch traceability and reproducibility
More informationAgilent Poroshell 120 Columns for HPLC and UHPLC PERFORM RUGGED, FAST LC WITH CONFIDENCE
Agilent Poroshell Columns for HPLC and UHPLC PERFRM RUGGED, FAST LC WITH CNFIDENCE AGILENT PRSHELL CLUMNS CAN MAKE EVERY LC AND LC/MS IN YUR LAB WRK EVEN HARDER We choose Poroshell because of its rugged
More informationGetting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008
Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008 Page 1 What are the Parameters Affecting Resolution? Isocratic Separations: physical and chemical separation
More informationThe Evolving HPLC Column Packings
The Evolving HPLC Column Packings GL Sciences has been steadily supplying with columns from Inertsil ODS, first-generation to InertSustain series, integration of state-ofthe-art technologies, and has established
More informationTrends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles
Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles Richard A. Henry, Separation Technology Consultant On behalf of: Supelco/Sigma-Aldrich, Bellefonte, USA
More informationN α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)
A new high performance reversed phase column that leverages the advantages of a C phase with the extra selectivity of a pentafluorophenyl (PP) phase. columns separate mixtures not possible with ordinary
More informationACE C18-PFP. A C18 bonded phase with unique selectivity. s Guaranteed reproducibility. lity. s Exceptional bonded phase stability
ACE CPFP A C bonded phase with unique selectivity & & & & & s Guaranteed reproducibility lity s Exceptional bonded phase stability s Hydrophobic and pentafluorophenyl mixed mode interaction HPLC Columns
More informationAQUASIL C18 Columns. AQUASIL 18 Columns TG Compatible with 100% aqueous mobile phase
AQUASIL C8 Columns AQUASIL 8 Columns TG0-0 Compatible with 00% aqueous mobile phase AQUASIL OH OH AQUASIL C8 columns provide a versatile C8 phase for a wide range of application areas. AQUASIL C8 columns
More informationAcclaim HPLC and UHPLC Columns
Acclaim HPLC and UHPLC Columns Optimal selectivity through innovative chemistries Designed for separating a variety of analytes, from small neutral and polar molecules to complex mixtures. Ideal for pharmaceutical,
More informationGeneral YMC Hydrosphere C Ordering Information
5 YMC ProFamily 5 YMC ProFamily Contents General... 54-6 YMC-Pack Pro C8... 6-65 YMC-Pack Pro C8... 66-67 YMC-Pack Pro C4... 68-69 YMC-Pack Pro C8 RS... 70-7 YMC Hydrosphere C8... 74-77 Ordering Information...
More information