System Extensions for Switchgear Manufacturing
|
|
- Poppy Booth
- 5 years ago
- Views:
Transcription
1 System Extensions Switchgear Manufacturing As a specialist safety interfaces, EFEN provides a range of accessories to complement the assembly und application of safe power distribution systems. System The wide range of accessories fuses and power distribution components is especially tailored to EFEN products. From solutions to satisfy rare requirements to special installation material to different fuse-monitoring options.
2 System Accessories page Busbar support page clamps page Clinch nuts page Insulator page 5 V-clamps page Technical data page 7 Busbar accessories Further accessories 00, 5 and 0 mm busbar spacings switchgear manufacturing Cable clamps 3
3 X Technical data, page 70, 75 Cable clamps Features: - Without mounting screws Cable clamp cable, Ø 3 KABELSCHELLE -3 EFEN KABELSCHELLE 3X -3 MM Cable clamp 3 cable, Ø Busbar support Amps Plug-in elements reduction to x 0 busbar ( pieces per support) Plug-in elements reduction to 0 x 0 busbar ( pieces per support) Plug-in elements reduction to x 0 busbar ( pieces per support) Busbar system, 0 x 0 busbar 75 2 STECKELEMENT X STECKELEMENT 0X STECKELEMENT X SAMMELSCHIENENHALTER 00MM Plug-in elements reduction to 0 x 0 busbar ( pieces per support) Plug-in elements reduction to x 0 busbar ( pieces per support) Busbar system, 0 x 0 busbar 2 2 STECKELEMENT 0X0 (0X0) VE STECKELEMENT X0 (X0) VE SAMMELSCHIENENHALTER 5MM Universal busbar support busbar dimensions 5,,, x 5, 0 mm Busbar support 0 mm 3-phase 00 SAMMELSCHIENENHALTER 0MM UNIVERSAL Sammelschienenhalter 3P Extension bracket +N to p 0 0 Seitenschutz Sammelsch.halter 3P Sammelsch.erweiterung P Extension f. lateral extension +N to p 0 Seitenschutz Sammelsch.erw. P Bracket f. lateral protection 0 mm 3p Feed clamps busbars with 5 or 0 mm thickness , 5-mm busbars.5, 0-mm busbars.5 35, 5-mm busbars.5 35, 0-mm busbar, 5-mm busbars, 0-mm busbars 70, 5-mm busbars 70, 0-mm busbars 5, 5-mm busbars 5, 0-mm busbars Feed clamp IP2X, V2MD 20sm/0rm 0 Leiteranschlusskl.,5- SS Leiteranschlusskl.,5- SS Leiteranschlusskl.,5-35 SS Leiteranschlusskl.,5-35 SS Leiteranschlusskl. - SS Leiteranschlusskl. - SS Leiteranschlusskl. -70 SS Leiteranschlusskl. -70 SS Leiteranschlusskl. -5 SS Leiteranschlusskl. -5 SS Einspeiseklemme IP2X V2MD 20sm/0rm M SETZMUTTER M SETZMUTTER M0 SETZMUTTER M0 M2 Setzmutter M2 M SETZMUTTER M Clinch nuts EFEN GmbH Technical changes reserved Released: April
4 X Technical data, page 73 Insulator Features: - Internally threaded Insulator H35 SW32 M0/M0 Insulator H35 SW32 / 2 ISOLATOR H35 SW32 M0/M0 ISOLATOR H35 SW32 / Insulator H35 SW32 M/M ISOLATOR H35 SW32 M/M Insulator H SW / ISOLATOR H SW / Insulator H SW M/M ISOLATOR H SW M/M Insulator H SW M0/M0 ISOLATOR H SW M0/M0 Insulator H0 SW3 M/M Insulator H0 SW3 / ISOLATOR H0 SW3 M/M ISOLATOR H0 SW3 / Insulator H0 SW3 M0/M0 ISOLATOR H0 SW3 M0/M0 Insulator H5 SW M/M ISOLATOR H5 SW M/M Insulator H5 SW / Insulator H5 SW M0/M0 ISOLATOR H5 SW / ISOLATOR H5 SW M0/M0 Insulator H SW M/M ISOLATOR H SW M/M Insulator H SW M0/M0 ISOLATOR H SW M0/M0 Insulator H SW M2/M2 ISOLATOR H SW M2/M2 Insulator H SW / Insulator H0 SW M/M ISOLATOR H SW / ISOLATOR H0 SW M/M Insulator H0 SW M0/M0 ISOLATOR H0 SW M0/M0 Insulator H0 SW M2/M2 ISOLATOR H0 SW M2/M2 Insulator H0 SW / ISOLATOR H0 SW / Insulator H0 SW M/M Insulator H70 SW0 M0/M0 ISOLATOR H0 SW M/M ISOLATOR H70 SW0 M0/M0 Insulator H70 SW0 M2/M2 ISOLATOR H70 SW0 M2/M2 Insulator H70 SW0 / ISOLATOR H70 SW0 / Insulator H70 SW0 M/ ISOLATOR H70 SW0 M/ Insulator H SW3 M/M ISOLATOR H SW3 M/M ISOLATOR H SW3 / Insulator HST SW3 /-0 ISOLATOR HST SW3 / Insulator HST SW M/M Insulator HST SW / ISOLATOR HST SW M/M ISOLATOR HST SW / Insulator HST SW M0/M0 ISOLATOR HST SW M0/M0 Insulator HST SW / ISOLATOR HST SW / Insulator HST SW M0/M0 ISOLATOR HST SW M0/M0 Insulator HST SW M2/M2 ISOLATOR HST SW M2/M2 Insulator HST35 SW32 M/M Insulator HST35 SW32 / ISOLATOR HST35 SW32 M/M ISOLATOR HST35 SW32 / Insulator HST35 SW32 M0/M0 ISOLATOR HST35 SW32 M0/M0 Insulator HST0 SW3 / ISOLATOR HST0 SW3 / Insulator HST0 SW3 M0/M0 Insulator HST0 SW3 M/M ISOLATOR HST0 SW3 M0/M0 ISOLATOR HST0 SW3 M/M Insulator HST5 SW M/M ISOLATOR HST5 SW M/M Insulator HST5 SW / ISOLATOR HST5 SW / Insulator HST5 SW M0/M0 ISOLATOR HST5 SW M0/M0 Insulator HST0 SW / Insulator HST0 SW M0/M0 ISOLATOR HST0 SW / ISOLATOR HST0 SW M0/M0 Insulator HST0 SW M2/M2 ISOLATOR HST0 SW M2/M2 Insulator HST70 SW0 / ISOLATOR HST70 SW0 / Insulator HST70 SW0 M0/M0 ISOLATOR HST70 SW0 M0/M0 Insulator HST70 SW0 M2/M2 ISOLATOR HST70 SW0 M2/M2 Insulator H SW3 / Insulator Features: - With stud EFEN GmbH Technical changes reserved Released: April
5 X Technical data, page 7 Terminal clamps direct connection to NH fuse-switches and NH fuse-rails Size Steel-box V-clamp 00 Amps PEN lug 00 MP double-clamp 00 MP clamp unit V2N -3 Satz Klemmen VST 00 Vk7 re/rm-sm/rm PEN-Anschluss m. Klemme re/rm-sm/rm MP-Doppelanschlusssch. m. Klemmen - MP-ANSCHLUSSEINHEIT V2N 20 SM V2N aluminum ged clamp Steel-box V-clamp -3-3 Satz Klemme V2N 0 rm/sm (3St.) Klemme E³ VST 2x-5sm SATZ (3ST) Steel-box V-clamp -3 Satz Klemme VSTR -20 rm Steel-box V-clamp, fixed upper part -3 Klemme E³ VST 35-20rm Satz (3St) Steel-box V-clamp, removable upper part - 3 Klemme E³ VEST 35-20rm Satz (3St) V2-MD clamp -3 Satz Klemmen V2 MD 20sm/0rm V2-MD clamp with lug Claw clamp M2-3 Bow-type flat-terminal clamp -3 Feed clamp IP2X with V2-MD clamp copper busbars 5 2 mm -3 PEN-Anschluss m. Klemme V2MD 20sm/0rm ANSCHLUSSKLEMMEN - SE FÜR S SATZ SATZ BÜGEL-FLACH-DIREKTANSCHLUSSK. Einspeiseklemme IP2X V2MD 20sm/0rm V2-MD insulating cap clamp cover -3 ISOLIERKAPPE V2 MD V2N insulating cap clamp cover -3 ISOLIERKAPPE V2N lange Variante Earthing cover E³ size -3 3P AU with cable Erdungsdeckel E³ Gr.-3 3P AU mit Kabel Maintenance accessories EFEN GmbH Technical changes reserved Released: April
6 Clinch nuts Busbars are fitted with clinch nuts to allow the direct attachment of NH s. Internal thread d (mm) s (mm]) Clinch Clinch Clinch Clinch Clinch M M0 M2 M,0 0,0 2,5,5, nut nut nut nut nut Terminal clamps NH fuse-switches Size Cross-section Torque 5 Nm re rm sm se re rm sm se - re rm sm se 5 Nm Steel-box V-clamp 00 PEN lug 00 MP double-clamp 00 MP clamp unit V2N rm re sm se 35 Nm V2N aluminum ged clamp rm re sm se 35 Nm Steel-box V-clamp -3 Steel-box V-clamp -3 Steel-box V-clamp, fixed upper part -3 Steel-box V-clamp, removable upper part -3 V2-MD clamp -3 V2-MD clamp with lug -3 Claw clamp M2-3 Bow-type flat-terminal clamp -3 Feed clamp IP2X with V2-MD clamp copper busbars 5 2 mm V2-MD insulating cap clamp cover V2N insulating cap clamp cover -3 2 x 70-2 x 70-2 x x rm - re - 20 sm - 20 se rm 35-0 re - 20 sm - 0 se rm 35-0 re - 20 sm - 0 se - 0 rm - 0 re sm - 0 se - 0 rm - 0 re sm - 0 se - se rm re 35-5 rm 35 - se 35 - sm 35-0 rm 35-0 re sm 35-0 se 5 Nm rm re sm se Nm Nm Nm Nm Nm Nm Nm Nm Nm clamping connection Nm busbar mounting EFEN GmbH Technical changes reserved Released: April 5 7
7 clamps Amps clamp mm busbars 0 LEITERANSCHLUSSKL.,5- MM² SS clamp mm busbars 0 LEITERANSCHLUSSKL.,5- MM² SS clamp 35 5 mm busbars 270 LEITERANSCHLUSSKL.,5-35 MM² SS clamp 35 0 mm busbars 270 LEITERANSCHLUSSKL.,5-35 MM² SS clamp 5 mm busbars 0 LEITERANSCHLUSSKL. - MM² SS clamp 0 mm busbars 0 LEITERANSCHLUSSKL. - MM² SS clamp 70 5 mm busbars 00 LEITERANSCHLUSSKL. -70 MM² SS clamp 70 0 mm busbars 00 LEITERANSCHLUSSKL. -70 MM² SS clamp 5 5 mm busbars 0 LEITERANSCHLUSSKL. -5 MM² SS clamp 5 0 mm busbars 0 LEITERANSCHLUSSKL. -5 MM² SS Description EFEN GmbH Technical changes reserved Released: April 5
8 s Description s, s, s, s, narrow narrow narrow narrow variant variant variant variant 2X 3X X 5X SILAS SILAS SILAS SILAS NH000 NH000 NH000 NH000 clamp rm/sm, narrow variant Einspeiseklemme - RM/SM LANH s s s s 2X 3X X 5X SILAS/IN SILAS/IN SILAS/IN SILAS/IN NH00 NH00 NH00 NH00 Weight in kg 0, 0,35 0,33 0,5 3 0, ,3 0, 0,0 0, Technical data acc. to DIN EN 097- VDE 00 T00 / IEC 097-:0 Description Materials Temperature resistance Insulation coordination Electric strength Impulse-withstand voltage Minimum air gap Minimum creepage distance Maximum operating voltage Rated operating voltage Short-circuit resistance Busbar E Cu 5 F Insulation PC/ABS extruded light gray RAL 7035 End cap PC/ABS injection-molded light gray RAL 7035 Terminal cover PA V0 injection-molded light gray RAL 7035 PC/ABS extruded VST B ISO = 3 C-UL9-VO/,5 PC/ABS injection-molded VST B ISO = 3 C UL9-V0, Overvoltage category III / pollution degree 2 PC / ABS > 32 kv / mm =/>,0kV (kv/mmls) > mm >,5 mm 90 V AC / 0 V DC 5 V 2,5 ka 00 ms / 00 V Busbar block length (m) Busbar cross-section Max. 35 Max Feed connected at busbar start or end Maximum Busbar current Is/phase Connecting cross-section A 35 0 A 2x35 0 A 2x35 5 fach A Feed connected at any other position Maximum Busbar current Is/phase Connecting cross-section Feed size 000 Feed size 00 Sn S3 S2 S S S2 IS Feed connected at busbar start or end S3 Resistance at 35 C ambient temperature and depending on feed point Sn IS Feed connected at any other position Note: If the feed is connected at the center of the busbar, the total outgoing current S... Sn of each busbar branch must not exceed the maximum busbar current Is/phase stated above. EFEN GmbH Technical changes reserved Released: April 5 9
9 Busbar support Busbar supports are available the following busbar center spacings: Center spacing 5 mm currents up to 00 A Center spacing 00 mm currents up to 2 A Center spacing 0 mm currents up to 00 A Busbar support, 00 A; Center spacing 5 mm Busbar dimensions Number per busbar Amps Busbar support 5 mm Plug-in elements Plug-in elements 0 x 0 mm 0 x 0 mm x 0 mm a = 0 x 0 mm Short-circuit current IP (ka) Short-circuit resistance diagram (5 mm) Busbar support spacing (mm) b = 0 x 0 mm c = x 0 mm 70 EFEN GmbH Technical changes reserved Released: April 5
10 Busbar support, 2 A; Center spacing 00 mm Busbar dimensions Number per busbar Amps Busbar support 00 mm 0 x 0 mm Plug-in elements Plug-in elements Plug-in elements x 0 mm 0 x 0 mm x 0 mm Short-circuit resistance diagram (00 mm) Short-circuit current Is (ka) 0 x 0 mm x 0 mm 0 x 0 mm x 0 mm Busbar support spacing (mm) EFEN GmbH Technical changes reserved Released: April 5 7
11 Busbar support, 00 A; Center spacing 0 mm Busbar dimensions Number per busbar Amps Busbar support, 0 mm 5,,, mm Short-circuit resistance diagram (0 mm) Busbar width 5,,, mm Short-circuit current Is (ka) x 0 mm x 5 mm x 5 mm x 0 mm 2 x 0 mm Busbar support spacing (mm) 72 EFEN GmbH Technical changes reserved Released: April 5
12 Thermosetting unsaturated polyester, red color Heat-resistant according to ISO 75/A > 0 C Threaded steel bushing, galvanized Self-extinguishing according to UL9-V0, halogen-free A B C ØD E F Rated operating voltage kv PowerLeakage Flexural frequency resisresiswithstand- tance tance voltage kn kv Tensile resistance Torsional resistance kn Nm H SW3 M/M H SW3 / H SW M/M H SW / H SW M0/M0 H35 SW32 M/M H35 SW32 / H35 SW32 M0/M0 H0 SW3 M/M H0 SW3 / H0 SW3 M0/M0 H5 SW M/M H5 SW / H5 SW M0/M0 H SW M/M H SW / H SW M0/M0 H SW M2/M2 H0 SW M/M H0 SW / H0 SW M0/M0 H0 SW M2/M2 H0 SW M/M H70 SW0 / H70 SW0 M0/M0 H70 SW0 M2/M2 H70 SW0 M/M M M M0 M M0 M M0 M M0 M M0 M2 M M0 M2 M M0 M2 M SW3 SW3 SW SW SW SW32 SW32 SW32 SW3 SW3 SW3 SW SW SW SW SW SW SW SW SW SW SW SW SW0 SW0 SW0 SW , 29, 29, ,0,0,0,0,0,0,0,0,5,5,5,5,5,5 3,0 3,0 3,0 3,0 3,0,0,0,0,0 7,5 7,5 7,5 7,5 7, ,0,0,0 0,0,0,0,0,0,0,0,0 3,0 3,0 7,0,0 9,0 9,0 9,0 9,0 9, ,5 5 2, ,0,,0,,,5,9,0,5,5 9,0,0 5,5,0,0 0,0 0,0,0 3,0 3, DIN EN 0 2 / VDE 03 T. CTI 00 Color: red EFEN GmbH Technical changes reserved Released: April 5 73 Isolators Material:
13 Isolators Material: Thermosetting unsaturated polyester, red color Heat-resistant according to ISO 75/A > 0 C Threaded steel bushing/stud, galvanized Self-extinguishing according to UL9-V0, halogen-free A B C ØD E F G Rated operating voltage kv Powerfrequency withstandvoltage kv Leaka- Flexural ge resisresis- tance tance kn Tensile resistance Torsional resistance kn Nm SW3 /-0 SW M/M SW / SW M0/M0 35 SW32 M/M 35 SW32 / 35 SW 32M0/M0 0 SW3 M/M 0 SW3 / 0 SW3 M0/M0 5 SW M/M 5 SW / 5 SW M0/M0 SW / SW M0/M0 SW M2/M2 0 SW / 0 SW M0/M0 0 SW M2/M2 70 SW0 / 70 SW0 M0/M0 70 SW0 M2/M M M0 M M0 M M0 M M0 M0 M2 M0 M2 M0 M2 SW3 SW SW SW SW32 SW32 SW32 SW3 SW3 SW3 SW SW SW SW SW SW SW SW SW SW0 SW0 SW , 29, 29, ,0,0,0,0,0,0,0,5,5,5,5,5,5 7, ,0 3,0 0,0 3,0 7,0 0,0 3,0 7,0 0,0 3,0 7, ,,0,,,5,9,0,5,5 9,0,5,0 5,5,0 0,0,0 3, DIN EN 0 2 / VDE 03 T. CTI 00 Color: red 7 EFEN GmbH Technical changes reserved Released: April 5
14 Cable clamp made of glass-fiber-reinced self-extinguishing halogen-free thermoplastic 3-00/ max / x Ø 3 mm max. 3x Ø 3 mm EFEN GmbH Technical changes reserved Released: April 5 75
15 Efficient Distribution When it comes to reliable power supply, replacing nuclear power by renewable energies is one of the greatest challenges. To this end, EFEN offers consistent solutions safety interfaces from power generation to power storage and to the selective control of consumers. Main Catalog Reliable Protection Reliable protection of people and assets is a key requirement of any power distribution system. The comprehensive solutions from EFEN ensure maximum safety in all areas of power supply, infrastructure and industry. Smart Control Higher energy efficiency reduces peak loads and lowers energy costs. Early-warning systems reduce minimal unplanned plant downtimes to the minimum. Smart solutions from EFEN ensure reliable communication and maximum availability of power distribution systems. EFEN GmbH Schlangenbader Str Eltville, Germany Tel. + 9 (0) Fax + 9 (0) efen@efen.com Logistic - Center EFEN GmbH Gewerbepark Nord 093 Uebigau Germany Tel Fax efen@efen.com Austria EFEN GmbH Prinzgasse /29/9 2 Wien Austria Tel.: +3 (0) Fax: suchacek@efen.com Slovakia EFEN Slovakia s.r.o Odborárska Bratislava Slovensko/Slovakia Tel Fax efen@efen.sk Hungary EFEN Division Guba Sándor u Kaposvár Hungary Tel Fax info@efen-hungaria.hu China Poland EFEN sp. z o.o. Aleja Młodych Siemianowice Śląskie Poland Tel Fax efen@efen.com.pl export@efen.com.pl EFEN Shanghai Office 00 Shangchen Rd (090 New Century Ave) Room 57 CIMIC Building Shanghai 0 China Tel Fax efen@efen.com.cn GB Main Catalog Products and Systems Smart Power Supply
BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008
LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect
More informationLV-MV INSULATORS INSULATORS
LV-MV INSULATORS LV-MV INSULATORS CONTENTS LOW VOLTAGE & MEDIUM VOLTAGE INSULATORS 0 0 0 0 0 0 0 0 /0 LV Insulators type SK LV Insulators type SR LV Insulators type RD LV Insulators type DS LV Insulators
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationBETA Protecting Miniature Circuit Breakers
Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional
More informationGeneral characteristics
General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and
More informationI nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationELINEMK Technical Characteristics Rated Current Busbar Code Standards Rated Isolation Voltage Max. Rated Operational Voltage Rated Frequency Pollution Degree Protection Degree External Mechanical Impacts
More informationNon-Contact Safety Systems CMS
Selection table for non-contact safety system // Evaluation units Connection Desi Read head contact assembly Assured switch-on distance S ao [mm] Assured switch-on distance S ar [mm] Number of outputs
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size
More informationSiemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.
Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More information5SP and 5SY Supplementary Protection UL 1077
Product Guide 5SP and 5SY Supplementary Protection UL 077 for North merican and International applications usa.siemens.com/5sy Table of contents Certifications, standards, features and description Characteristic
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More informationDATA RACK BUSBAR. Data Rack Busbar Systems A.
Data Rack Busbar Systems 250...1000 A www.eae.com.tr Overview Overview To power the mission critical IT infrastructures on the Data Rack Cabinets, EAE offers a highly flexible and reliable Busbar System
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationImformation of C091D series
Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationFAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN
FAZ, AZ High-Capacity Tripping Characteristics Moeller HPL011-001/00 1/07 FAZ tripping characteristics at 0 C: B, C, D to IEC/EN 0 9 FAZ tripping characteristics at 0 C: R to IEC/EN 0 97 t [s] 700 00 100
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationMCB NB1-63H Miniature Circuit Breaker
NB-H Miniature Circuit Breaker. General. Function protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation, NB-H circuit-breakers are used
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationZelio Relay - Solid State Relays
Selection guide SSR solid state relays Applications Panel mounted PF00--Q Contact type N/O SPST contact Control voltage ranges a 0 0 V c V Operating voltages a 0 V, 0 V, 0 V Type of switching a Zero voltage
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More informationINSULATORS INSULATORS
INSULATORS INSULATORS INSULATORS CONTENTS > INDOOR INSULATORS 0 /02 Post Insulators 03 /04/0 Capacitive Divider Insulators 0 Wall Bushings /07 08 Bolt Bushings /0 GENERAL INFORMATION ON INSULATORS Rated
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationSealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards
Miniature circuit breaker ETIMAT 7,7 0.5 Rated voltage Rated current Rated frequency Rated short-circuit capacity Energy limiting class characteristic Build-in width Mounting on the rail 0/00 V AC, max.
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 14 year DC life 56V DC working voltage Resistive cell balancing Overvoltage outputs High power density 4U, half-rack package UL registered TYPICAL APPLICATIONS UPS systems
More informationLinear actuator Econom 2. Our intelligent model: Econom 2. Econom 2
Linear actuator Econom 2 Our intelligent model: Econom 2 Econom 2 Linear actuators Econom 2 Description Applications Facts The users of the Econom 2 come from many different industries: From architects
More informationLD-LP-LL-LC Rope Safety Switches with reset for emergency stop
TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density TYPICAL APPLICATIONS
More informationNYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38
NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38 NYY-J/-O Energy and control cable acc. to DIN VDE 0276 and HD 603 Application Indoor and outdoor installation, laying in ducts and underground, for power stations,
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationEasyDry transformer bushing Better performance made easy. Power and productivity for a better world TM ABB
EasyDry transformer bushing Better performance made easy Power and productivity for a better world TM ABB ABB, the world leader in high voltage bushing technology Global experience and resources The ABB
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION RATED PRIMARY OLTAGE () This is the supply assigned to the transformer by the manufacturer. RATED SECONDARY OLTAGE () This is the secondary output assigned to the transformer when
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme
Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive
More informationSPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION January 2017 SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM I. SCOPE This
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More informationKSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16
Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationX T O B P 1 6 B C 1 S
9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............
More informationMKV AC Capacitors Damping B High dielectric strength High peak-current capability Especially suitable for snubber circuits
MKV AC Capacitors B 25 835 High dielectric strength High peak-current capability Especially suitable for snubber circuits Construction Self-healing Plastic dielectric Oil-impregnated tubular windings (no
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n
Varius SUMMARY OF MODELS OF HRC FUSE-LINKS Type A / Rated current I n up to A up to up to A Rated voltage U n AC V, V V, V, 9 V V, V, 9 V DC V V V Fuse-link size x8 x x8 Utilization category of the fuse-link
More informationCNY64/ CNY65/ CNY66. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The CNY64/ CNY65/ CNY66 consist of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead plastic package. The
More informationct m ive p 5/EC Thermal cut-outs
RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature
More informationSIRCOVER Manual transfer switches from 125 to 3200 A
Manual transfer switches svr_149_a 3200 A Function are manual multipolar transfer switches with positive break indication. The family includes two ranges: AC for dead time switching (I-0-II), for overlapping
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationTCLT10.. Series. Optocoupler with Phototransistor Output. Vishay Semiconductors. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The TCLT1.. Series consists of a phototransistor optically coupled to a gallium arsenide infraredemitting diode in a 4-lead SO6L package. The elements
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More informationBASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS
Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear
More informationUL 1077 DIN Rail Supplementary Protectors
UL 0 DIN Rail Supplementary Protectors Product Overview UL 0 DIN Rail Supplementary Protectors PRODUCT OVERVIEW Product Overview Standard Features WMZS breaker terminals provide finger and back-of-hand
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More informationBlocks and Holders POWR-BLOKS. Connectors. Ampere Ratings. Ordering Information. Applications. Specifications. Distribution/Splicer Blocks and Covers
Connectors Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine stranded
More informationTEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations
Test Report issued under the responsibility of: TEST REORT IEC/EN 60898-1 Circuit-breakers for over current protection for household and similar installations Report Reference No.... : 130100913SHA-004
More informationSurface-mounting thermostats Series ATH
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationAmphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.
mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection
More informationSwitches in conformity with ATEX directive
E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category
More informationCNY17 Series. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards.
Optocoupler with Phototransistor Output Description The CNY7 series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 6-lead plastic dual inline package.
More informationMACH LED. and unsusceptible to lubricants and coolants.
EN MACH LED MACHiNE luminaire 2 MACH LED. A highlight when it comes to ADAptability. 1 2 The trend toward miniaturization in the mechanical and plant engineering industry has turned the standard-compliant
More informationATyS Automatic and remotely operated transfer switches from 125 to 3200 A
atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase
More informationTCET110.(G) up to TCET4100. Optocoupler with Phototransistor Output. Vishay Telefunken. Description. Applications. VDE Standards
Optocoupler with Phototransistor Output Description The TCET11./ TCET2/ TCET4 consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead up to 16-lead plastic
More information3VT4 Molded Case Circuit Breakers up to 1000 A
VT4 Molded Case Circuit Breakers up to 00 A Catalog Technical nformation VT4 Molded Case Circuit Breakers up to 00 A General data / - Overview Circuit breakers Switch disconnectors / - Selection and ordering
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationAnalogue Meters CQ2x07 series
Analogue Meters CQ2x07 series Analogue Power Meters Active, reactive, apparent power meters and Power factor meters with exchangeable scales EQ0207/2207/0107/2107 & YQ0207/2207/0107/2107 o Measurement
More informationVK2 volume flow controller Overview
New option with sound attenuator Maintenance-free VK2 volume flow controller that operates without an auxiliary power supply, for ventilation and air conditioning systems. Adjustable on site. Outstanding
More informationGeneral characteristics, Products
The Feature Packed line of Manual Motor Protectors Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload
More informationIndependent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests
Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION on the given range of performed tests 3M Laboratories Europe Zweigniederlassung der 3M Deutschland GmbH Carl-Schurz-Str.
More informationPower Distribution System SVS04
Power Distribution ystem V0 Description The V0 power distribution system for symmetrical DIN rail mounting is designed to distribute power from a switchmode power supply to or 8 channels. elective protection
More informationPower Distribution System SVS04
Power Distribution ystem V0 Description The V0 power distribution system for symmetrical DIN rail mounting is designed to distribute power from a switchmode power supply to or 8 channels. elective protection
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationSemiconductor (AC) fuses
BS88 Fuses x1, 17x9, X17x9, 6 VAC EXTREMELY HIGH BREAKING CAPACITY FUSES: PROTECTION OF POWER SEMICONDUCTORS AS PER IEC STANDARD 6069.1 AND 6 V VOLTAGE RATING COMPLYING WITH IEC GR CLASS (RATINGS FROM
More informationT20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en
T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission
More information2014 REV 01 POWER ELECTRONICS CAPACITORS. AC Applications Metallized Polypropylene Self Healing
2014 REV 01 POWER ELECTRONICS CAPACITORS AC Applications Metallized Polypropylene Self Healing 1. COMPANY PROFILE OUR MISSION: Develop and supply high-quality capacitors, providing all the customers with
More informationTEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation
age 1 of 92 R e port ref. No.: C009-CB2012CQC-044407 Test Report issued under the responsibility of: TEST REORT IEC 60 898-1:2002 Circuit-Breakers for overcorrect protection for household and similar installation
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationC120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka
C0N circuit-breakers B, C and D curves EN 09/EN 009: 0000 - IEC 097-: 0 ka function # protection of cables against overloads and short-circuits in final distribution # manual control and isolation # earth
More informationK04 TYPE -40 C +85 C 20000H
K04 TYPE -40 C +85 C 20000H Extended life. Surge-proof capacitor in aluminium can with insulation sleeve. To be mounted with ring clips or with threaded stud. Designed for high resistances to voltage spikes.
More informationTeSys circuit-breakers
Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the
More informationGESELLSCHAFT FÜR ELEKTRISCHE HOCHLEISTUNGSPRÜFUNGEN Mitglied der Short-Circuit-Testing Liaison (STL) Test Report
Mitglied der Short-Circuit-Testing Liaison (STL) Test Report Report-No.: 9725Fr Copy-No.: 00 Contents: 16Sheets Equipment under Test: Manufacturer: Client: Metal-enclosed, single-pole metal-clad and SF
More informationDRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories
Practice-iented, scalable and thought out in detail: The new drum mot makes it easy to ild a completely indidual convey system and is dimensioned f the higher requirements f permissible belt tension from
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationAmerican Zettler AZ742 RELAY Datasheet
American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationTHREE PHASE CAPACITOR For WIND TURBINES
RS/Cond 28.04.2003 Pg: 1 / 3 THREE PHASE CAPACITOR For WIND TURBINES Applications: Three-phase capacitor for Wind Turbine has been designed for power factor correction in high harmonic current content.
More informationIssued August DATA SHEET. 3VT5 MCCB up to 1600 A
ssued August 9 DATA SHEET VT5 MCCB up to 0 A Based on Siemens Catalog V 8 Standard circuit breakers Releases Technical specifications Specifications VT5 circuit breakers Switch disconnectors Type Standards
More information