Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Size: px
Start display at page:

Download "Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme"

Transcription

1 Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme

2 The Company General information These connectors are designed and produced in conformity with the voltage directive (73/23/EWG) respectively Gerätesicherheitsgesetz (German law) and are especially in accordance with the standards DIN EN (VDE0627); IEC (VDE 01- nad IEC 605. The connectors may be used only within the technical ratings. The indicated dimensions with the panel cut-outs represent reference values and are in the concrete application with products to be co-ordinated. It is the users responsability to check whether the components illustrated in this catalogue comply with different regulations from those stated in special fields of application which we are unable to foresee. We reserve the right to modify designs in order to improve quality, keep pace with technological advancement or meet particular requirements in production. This catalogue must not be used in any form or manner without our prior approval in writing (Copyright Law, Fair Trading Law, Civil Code). 2 Amphenol

3 C 146 Characteristics Series Number of contacts C 146 D C 146 DD C 146 E C 146 EE Termination Wire gauge Flammability (UL 94) Certifications according DIN EN Insertion and withdrawal force in N Rated voltage (VDE) Rated voltage (UL, CSA) in V Pollution degree Installation (overvoltage) category Rated current (Tu= C) in A Lower temperature in C Upper temperature in C Series Number of contacts Termination Contacts Wire gauge C 146 C 146 A Flammability (UL 94) Certifications Insertion and withdrawal force in N Rated voltage (VDE) Rated voltage (UL, CSA) in V Pollution degree Installation (overvoltage) category Rated current (Tu= C) in A Lower temperature in C Upper temperature in C III - 0 III III ,5 and V + 0V 1V + 0V III 0 Amphenol 3

4 C 146 E Inserts screw termination 6+PE C146 A (with wire protection) C146 B (with wire protection) screw termination +PE C146 A0 2 1 (with wire protection) C146 B0 2 1 (with wire protection) for stamped contacts 6+PE C146 A C146 B for stamped contacts +PE C146 A C146 B for turned contacts 6+PE C146 A C146 B for turned contacts +PE C146 A C146 B screw termination +PE C146 A0 2 1 (with wire protection) C146 B0 2 1 (with wire protection) screw termination 2) 24+PE C146 A (with wire protection) C146 B (with wire protection) for stamped contacts +PE C146 A C146 B for stamped contacts 2) 24+PE C146 A C146 B for turned contacts +PE C146 A C146 B for turned contacts 2) 24+PE C146 A C146 B C 146 EE Inserts +PE 18+PE C146 A0 500 C146 B0 500 C146 A C146 B PE 46+PE C146 A0 500 C146 B0 500 C146 A C146 B For versions without wire protection please refer C146 main catalog or www. amphenol.info 2) For 48 pol version please refer C146 main catalog or 4 Amphenol

5 C 146 E / C 146 EE Contacts Supplied as for wire gauge AWG Pieces Stamped single contacts Stamped contacts on reel for hand crimp tools Stamped contacts on reel for crimp machines Contact feeding right hand Contact feeding left hand Turned crimp contacts Single contact ale contact VN ( VN ( ZN ( ZN ( Female contact VN ( VN ( ZN ( ZN ( HN ( HN ( HN ( HN ( TN ( TN ( TN ( TN ( 0,5 mm 2 VN (C VN (C 0,75-1,0 mm 2 18 VN (C VN (C 1,5 mm 2 VN (C VN (C 2,5 mm 2 14 VN (C VN (C 4,0 mm 2 12 VN (C VN (C For gold plated contacts please refer C146 main catalog or C 146 A Inserts screw termination 3+PE C146 A C146 B screw termination 4+PE C146 A C146 B screw termination +PE C146 A ) (with wire protection ) C146 B ) (with wire protection ) screw termination +PE 3) C146 A ) (with wire protection ) C146 B ) (with wire protection ) 2) For versions without wire protection please refer C146 main catalog or www. amphenol.info 3) For pol versions please refer C146 main catalog or Amphenol 5

6 C 146 Frames Frame for 2 modules Positions A - B Frame for pin modules C146 P G8 C146 P G8 (2 x PE) Frame for socket module C146 S G8 C146 S G8 (2 x PE) Frame for 3 modules A - C C146 P 001 G8 C146 P 002 G8 (2 x PE) C146 S 001 G8 C146 S 002 G8 (2 x PE) Frame for 5 modules A - E C146 P 001 G8 C146 P 002 G8 (2 x PE) C146 S 001 G8 C146 S 002 G8 (2 x PE) Frame for 7 modules A - G C146 P G8 C146 P G8 (2 x PE) C146 S G8 C146 S G8 (2 x PE) T - Z C146 P24 1 G8 C146 P24 2 G8 (2 x PE) C146 S24 1 G8 C146 S24 2 G8 (2 x PE) C 146 odules Contacts pin module socket module Supplied as for wire gauge AWG Pieces ale contacts Female contacts contacts for stamped Single contacts for hand crimping tools gold plating contacts C146 A 001 G8 C146 B 001 G8 0,09-0, mm VN (2) VN (2) 0, - 0,50 mm VN (2) VN (2) Contacts on reel for hand crimping tools 0,09-0,mm ZN (2) ZN (2) 0, - 0,50 mm ZN (2) ZN (2) Contacts on reel for crimp machines Contact feeding 0,09-0, mm TN (2) TN (2) left hand 2) 0, - 0,50 mm TN (2) TN (2) Stamped single contacts silver plating contacts for stamped contacts C146 D 001 E8 C146 C 001 G8 contacts for turned contacts C146 A 001 E8 C146 B 001 E8 Standard High current 0,14-0,5 mm 2 Stamped contacts on reel for hand crimp tools Standard High current 0,14-0,5 mm Stamped contacts on reel for crimp machines Contact feeding 0,14-0,5 mm 2 left hand 2) Standard High current Turned crimp contacts Single contact 0,14-0,37 mm 2 0,5 mm 2 0,75-1,0 mm 2 1,5 mm 2 2,5 mm VN ( VN ( VN ( VN ( VN ( ZN ( ZN ( ZN ( ZN ( ZN ( ZN ( ZN ( ZN ( ZN ( ZN ( silver plating TN ( TN ( TN ( TN ( TN ( VN (C VN (C VN (C VN (C VN (C VN ( VN ( VN ( VN ( VN ( silver plating TN ( TN ( TN ( TN ( TN ( silver plating VN (C VN (C VN (C VN (C VN (C 6 Amphenol

7 5 contacts for turned contacts pin module socket module C146 A E8 C146 B E8 3 contacts for turned contacts C146 A E8 C146 B E8 5 contacts for stamped contacts C146 D E8 (4 pol) C146 D E8 (4 + PE) C146 D E8 (5 pol) C146 C E8 (4 pol) C146 C E8 (4 + PE) C146 C E8 (5 pol) 3 contacts for coax contacts C146 A E8 C146 B E8 Turned crimp contacts Supplied as for wire gauge AWG Pieces Single contact 0,5 mm 2 0,75-1,0 mm 2 1,5 mm 2 2,5 mm 2 4,0 mm Turned crimp contacts Single contact 1,5 mm 2 2,5 mm ,0 mm ,0 mm 2,0 mm 2 8 Stamped single contacts 2,5-4,0 mm silver plating ale contacts VN (C VN (C VN (C VN (C VN (C VN (C VN (C VN (C VN (C VN (C VN ( VN ( VN ( Contacts on reel for hand crimping tools ZN ( ZN ( Contacts on reel for crimp machines Contact feeding - 00 TN ( left hand 2) TN ( 2,5-4,0 mm TN ( Crimp contacts for cable size Single contact RG 174, 179, 3 RG D D Female contacts VN (C VN (C VN (C VN (C VN (C silver plating VN (C VN (C VN (C VN (C VN (C VN ( VN ( VN ( ZN ( ZN ( TN ( TN ( TN ( 17D D contacts for turned contacts RJ module Pneumatic module, 1 or 2 connections C146 A E8 C146 E E8 C146 G G8 (2,5 mm) C146 G G8 (4,0 mm) C146 B E8 C146 F G8 C146 H G8 (2,5 mm) C146 H G8 (4,0 mm) Turned crimp contacts Single contact 1,5 mm 2 2,5 mm 2 4,0 mm 2 6,0 mm 2,0 mm 2 Turned crimp contacts 0,14-0,37 mm 2 0,5 mm 2 0,75-1,0 mm 2 1,5 mm 2 2,5 mm silver plating VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C VN ( C C146 G G8 (2,5 mm) C146 G G8 (4,0 mm) C146 H G8 (2,5 mm) C146 H G8 (4,0 mm) For gold plated contacts please refer C146 main catalog or 2) For right feeding contacts please refer C146 main catalog or Amphenol 7

8 C 146 D Inserts 7+PE C146 A C146 A C146 B C146 B pol C146 A C146 A C146 B C146 B PE C146 A C146 A C146 B C146 B PE 2) C146 A C146 A C146 B C146 B PE C146 A C146 A C146 B C146 B PE 3) C146 A C146 A C146 B C146 B C 146 DD Inserts 24+PE C146 A C146 B PE C146 A C146 B PE C146 A C146 B PE C146 A C146 B C 146 D / C 146 DD Contacts 4) Supplied as Stamped single contacts Standard High current for wire gauge AWG Pieces 0,14-0,5 mm For versions with two PE contacts please refer C146 main catalog or 2) For 50 pol versions please refer C146 main catalog or 3) For 128 pol versions please refer C146 main catalog or 4) For gold plated contacts please refer C146 main catalog or ale contact VN ( VN ( Female contact VN ( VN ( VN ( VN ( VN ( VN ( VN ( VN ( 8 Amphenol

9 C 146 D / C 146 DD Contacts Supplied as for wire gauge AWG Pieces Stamped Contacts on reel for hand crimp machines Contact feeding left hand 0,14-0,5 mm Standard High current Stamped Contacts on reel for hand crimp tools Standard High current Turned crimp contacts Single contact 0,14-0,5 mm ,14-0,37 mm 2 0,5 mm 2 0,75-1,0 mm 2 1,5 mm ,5 mm 2 14 For gold plated contacts please refer C146 main catalog or ale contact TN ( TN ( Female contact TN ( TN ( TN ( TN ( TN ( TN ( TN ( TN ( ZN ( ZN ( ZN ( ZN ( ZN ( VN ( VN ( VN ( VN ( VN ( ZN ( ZN ( ZN ( ZN ( ZN ( VN ( VN ( VN ( VN ( VN ( IP 68 Housings General Characteristics Degree of protection housing Degree of protection cover Locking System Climatical Characteristics Climatic category Temperature range aterials Housing Protective cover Rubber gasket Locking screws Surface Side entry Top entry Standard IEC 605 IEC 605 IEC IEC C 146 E 6 pol. C odule C 146 DD 24 pol. C 146 EE pol. C146 68R C146 68R C 146 E pol. C odule C 146 DD 42 pol. C 146 EE 18 pol. Value IP68 IP68 2 screws // - C/+ C Aluminium die cast alloy Aluminium die cast alloy Conductive neoprene Stainless steel Special surface C 146 E pol. C 146 E 5 odule C 146 DD pol. C 146 DD 72 pol. C 146 DD pol. C 146 E 24 pol. C 146 E 7 odule C 146 D 64 pol. C 146 DD 8 pol. C 146 EE 46 pol. Side entry Top entry C146 68F C146 68R C146 68R C146 68R C146 68R Side entry Top entry C146 68F C146 68F C146 68R C146 68R C146 68F Information: All housings without stud 2) For dimensions please request drawings 3) bulkhead housings with cable outlets available upon request Amphenol 9

10 IP 65 Housings General Characteristics Degree of protection housing Degree of protection cover Locking System Climatical Characteristics Climatic category Temperature range aterials Housing Protective cover Rubber gasket Locking lever Hood, entry Hood, entry Housing, bulkhead mounting Hood, entry High profile Low profile High profile Low profile High profile Low profile C 146 E 6 pol. C odule C 146 DD 24 pol. C 146 EE pol. 13,5 C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 G C146 R C146 R Standard IEC 605 IEC 605 IEC IEC C146 R C146 R C146 G C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 R Information: housings with stud 2) etric housings without stud 3) EI housings are also available 4) For dimensions and panel cut outs please refer C146 main catalog and 5) For bulk head mounting housings with cable outlet, coupling housings and housings with cover please refer C146 main catalog and 6) Housings with more than one cable outlet are available upon request Value C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R IP65 IP65 locking lever // - C/+ C Aluminium die cast alloy Aluminium die cast alloy NBR, CR steel/zinc coated L B H L B H C 146 E pol. L B H C 146 E 24 pol. L B H C 146 E pol. C odule C odule C odule C 146 D pol. C 146 D 64 pol. C 146 DD 42 pol. C 146 DD 72 pol. C 146 DD 8 pol. C 146 HvE 3 pol. C 146 HSE 6pol. C 146 HvE pol. C 146 EE 18 pol. C 146 EE pol. C 146 EE 46 pol. C146 G C146 G C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 F ,0 28,5 C146 F ,0 28,5 C146 F ,5 Amphenol

11 Hood, entry Housing,bulkhead Low profile High profile 13,5 C 146 E 6 pol. C odule C 146 DD 24 pol. C 146 EE pol. C146 G C146 G C146 R C146 R C146 G C146 G C146 G C146 R C146 R L B H L B H C 146 E pol. L B H C 146 E 24 pol. L B H C 146 E pol. C odule C odule C odule C 146 D pol. C 146 D 64 pol. C 146 DD 42 pol. C 146 DD 72 pol. C 146 DD 8 pol. C 146 HvE 3 pol. C 146 HSE 6pol. C 146 HvE pol. C 146 EE 18 pol. C 146 EE pol. C 146 EE 46 pol. C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 F ,0 C146 F ,0 28,5 C146 F ,0 28,5 C146 F ,5 C 146 D 7 pol. C 146 A 3/4 pol. L B H C 146 D 7 pol. C 146 A 3/4 pol. L B H Hood, entry 11 C146 G C146 R (gray) C146 R (bl) 26,5 33,5 26,5 33,5 26,5 33,5 50,0 50,0 50,0 Housing bulkhead mounting (incl. gasket) C146 F (gray) C146 F (bl),0 28,0 22,0,0 28,0 22,0 Hood, entry 11 C146 G C146 R (gray) C146 R (bl) 26,5 33,5 26,5 33,5 26,5 33,5 48,0 Housing bulkhead end mountin 48,0 (incl. gas 48,0 C146 F ,0 27,8 26,0 L B H L B H L B H Hood, entry Hood, entry Housing, bulkhead moun Low profile High profile Low profile High profile 13,5 13,5 C 146 D 15 pol. C 146 A pol. C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 F ,5 53,0,5 53,0,5 53,0,5 53,0,5 64,5,5 64,5,5 64,5,5 64,5,5 53,0,5 53,0,5 53,0,5 53,0,5 64,5,5 64,5,5 64,5,5 64,5 81,0,5 26,0 C146 D pol. C146 A pol. C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 G C146 G C146 R C146 R C146 F ,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5 58,0 58,0 58,0 70,5 70,5 70,5 70,5 58,0 58,0 58,0 58,0 70,5 70,5 70,5 70,5 96,0,5 26,0 C 146 D 50 pol. C 146 A pol. C146 G C146 G C146 R C146 R C146 R C146 G C146 G C146 R C146 R C146 R C146 F C146 F , ,0 2, ,0 Information: housings with stud 2) etric housings without stud 3) EI housings are also available 4) For dimensions and panel cut outs please refer C146 main catalog and 5) For bulk head mounting housings with cable outlet, coupling housings and housings with cover please refer C146 main catalog and 6) Housings with more than one cable outlet are available upon request Amphenol 11

12 Kits C146 E Screw Termination Kits consist of insert with contacts, housing and gland bushing for housings with cable outlet No. of Pos. Component parts Cable entry 6 POL C146 E C146 E C146 G C146 A VN C146 G C146 A VN Hood profile Spring cover C146 E C146 E C146 G C146 A VN C146 G C146 A VN p a n e l C146 E C146 E C146 F C146 B C146 F C146 B no yes POL C146 E0 9 1 C146 G C146 A0 2 1 VN C146 E C146 E C146 G C146 A0 2 1 VN C146 G C146 A0 2 1 VN C146 E C146 G C146 A0 2 1 VN p a n e l C146 E C146 E C146 F C146 B0 2 1 C146 F C146 B0 2 1 no yes POL C146 E0 9 1 C146 E C146 G C146 A0 2 1 VN C146 G C146 A0 2 1 VN p a n e l C146 E C146 E C146 F C146 B0 2 1 C146 F C146 B0 2 1 no yes 12 Amphenol

13 Kits C146 E Screw Termination Kits consist of insert with contacts, housing and gland bushing for housings with cable outlet No. of Pos. Component parts Cable entry 24 POL C146 E C146 G C146 A VN Hood profile Spring cover C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 E C146 G C146 A VN C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 E C146 G C146 A VN C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN C146 E C146 G C146 A VN p a n e l C146 E C146 E C146 E C146 F C146 B C146 F C146 B C146 F C146 B no no yes Amphenol 13

14 Gland bushings Gland bushings IP 65 Drawing Pieces 11 VN X (Thermoplast) VN X (Thermoplast) 13,5 VN X VN X VN X VN X VN X VN X VN X 36 VN X VN X 42 VN X 50 VN X etal, with standard diameter 11 VN X (Thermoplast) 13,5 VN X VN X VN X VN X 36 VN X 42 VN X Gland bushing with vibration protection IP 67 Clamping range Ø A (mm) Pieces 4 - mm 24,4 11 VN X 4 - mm VN X 5-12 mm 26,5 13,5 VN X 6-12 mm 24 VN X 9-14 mm,5 VN X 9 - mm 28 VN X mm 36,2 VN X - mm 36 VN X 14 - mm,6 VN X - 28 mm 46 VN X Gland bushing EC IP 68 Clamping range Ø Pieces 4 - mm 11 VN X 5,5 - mm VN X 5-12 mm 13,5 VN X 8-13 mm VN X 8-14 mm VN X mm VN X 11-17,5 mm VN X 15 - mm VN X - mm VN X mm VN X 14 Amphenol

15 Crimping tools for stamped contacts Description Removal tool for contacts for wire gauge Contact locator Crimping dies Tools FG Service crimping tool Crimping fool for single contacts 0,14-0,5 mm 2 TA ,14-0,5 mm 2 TA TA TA TA TA TA TA 0000 TA 0500 Further information see catalogue Tools Hand crimping tool for turned contacts Description Contact Ø for wire gauge incl. contact locator and calibration pin 1,0 mm 0, - 0,5 mm 2 TB ,6 mm 0,14-2,5 mm 2 TB ,5 mm (wiht clip) 0,5-4 mm 2 TB ,5 mm (wihtout clip) 0,5-4 mm 2 TB ,6 mm (wiht clip) 1,5 - mm 2 TB ,6 mm (wihtout clip) 1,5 - mm 2 TB Indent hand crimping tool for turned contacts 1,6 mm LWL TB Amphenol 15

16 International Amphenol

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors.

Amphenol Amphenol-Tuchel Electronics GmbH. C 091 A/B/D Series. Circular Connectors. mphenol mphenol-tuchel Electronics GmbH C 09 //D Series Circular Connectors www.industrial-amphenol.com Note from the CEO Ladies and Gentlemen, For over years mphenol has enjoyed success as the interconnection

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive E Switches in conformity with ATEX directive page / General Catalog 09-0 Technical concepts page /9 A B Position switches FD series page / Category Zone Approvals Article code extension G M ATEX category

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear

More information

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop TECHNICA DATASHEET D-P--C Rope Safety Switches with reset for emergency stop Metal or polymer housing, from one or three conduit entries Protection degree IP6 In conformity with EN ISO 13850 contact blocks

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/08 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

MINIATURE MICROSWITCHES - PREMIUM

MINIATURE MICROSWITCHES - PREMIUM 0/06 MINIATURE MICROSWITCHES - PREMIUM V - 86 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Broad range of operating forces

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP

Table of Contents Pin-Configuration Selection Guide for HDE, HDS, & EFP Table of Contents -Configuration Selection Guide for HDE, HDS, & EFP Service Voltage Rating... Electrical Service Ratings... Ampacity Ratings by Contact... Electrical Service Ratings Explained... Operating

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Surface-mounting thermostats Series ATH

Surface-mounting thermostats Series ATH JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Field IT 50T Series Transmitters

Field IT 50T Series Transmitters Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology

More information

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

THM80X Series  Feature Application. Temperature & Humidity / Flow Measuring Specialist THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication Surge Arrester Protects switches, HUBs and telecommunication systems Class D according to EN 0 possible (Gigabit Ethernet) Variably equippable patch panels Units available with plug-in inputs and outputs

More information

Preliminary Product Information. LIC 4000 Series Exposed Absolute Linear Encoders

Preliminary Product Information. LIC 4000 Series Exposed Absolute Linear Encoders Preliminary Product Information LIC 4000 Series Exposed Absolute Linear Encoders April 2009 LIC 4000 Series Exposed absolute linear encoders Measuring lengths up to 27 m Measuring steps to 0.001 µm (1

More information

Installation Equipment

Installation Equipment Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS

SERIES 10 ELEKTRISCHE STECKVERBINDER FÜR MEERES- UND MARINETECHNIK HIGH PERFORMANCE UNDERWATER ELECTRICAL CONNECTORS SERIES 0 ELEKTRISHE STEKVERINDER FÜR MEERES- UND MRINETEHNIK HIGH PERFORMNE UNDERWTER ELETRIL ONNETORS Leinestraße D-9 Neumünster Tel. +9 - - 98-0 Fax +9 - - 98 - http://www.gisma-connectors.de E-Mail:

More information

Absolute encoders multiturn

Absolute encoders multiturn elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature

More information

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty Sensor/actuator boxes M distributor with metal thread, heavy-duty Notes: Suitable for SPEEDCON and M standard, see page:. For further technical data, see: www.phoenixcontact.net/catalog With a master cable

More information

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell Wireless Load Cell Features Standard single part line pull sizes ranging from 5,000 to 600,000 lb. All stainless frame and hardware Heavy duty construction from 17-4PH1150 stainless steel (17-4PH1025 on

More information

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Cabinets G  integrated in upright Handle strip in side panel Easy solution for shortened doors Overview... 0 Cabinets... 1 Cabinets Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 Subracks/ 19" chassis... 6 02002002 Front panels,

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

ct m ive p 5/EC Thermal cut-outs

ct m ive p 5/EC Thermal cut-outs RoHS Compliant Directive //EC Marking of switches type: AM, AF, AB,, AA. AM0. 0. 0 0/0 -. 0 Strip length Second conductor length First conductor length Type of thermal cut-out Rated switching temperature

More information

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG 05 Totally Integrated Power SENTRON Configuration Manual Edition 0/0 siemens.com/lowvoltage Siemens AG 05 Siemens AG 05 Introduction 5SL miniature circuit breakers 5SY and 5SP miniature circuit

More information

1-Gang Thermoset 2051 A, B, LA, V, W 2-Gang Thermoset 2052 A, LA, V, W 3-Gang Thermoset 2063 A, LA, V, W 4-Gang Thermoset 2064 A, LA, V, W

1-Gang Thermoset 2051 A, B, LA, V, W 2-Gang Thermoset 2052 A, LA, V, W 3-Gang Thermoset 2063 A, LA, V, W 4-Gang Thermoset 2064 A, LA, V, W Wallplates Decorator Screwless, Mid-Size and Standard Contemporary design, sleek elegant lines, and a multitude of material, size and color choices make the Decorator Style an easy choice. Decorator Opening

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

What You Need to Get Started INSTALLATION GUIDE

What You Need to Get Started INSTALLATION GUIDE INSTALLATION GUIDE SBS-96F SHIELDED BACKSHELL This guide describes how to assemble and install the SBS-96F shielded backshell with low-voltage SCXI modules, VXI-DAQ modules, or low-voltage TBX terminal

More information

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3.

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3. Overview..... 0 NOVASTAR Cabinets NOVASTAR Cabinets...... 1 Wall mounted cases........ 2 Accessories for cabinets and wall mounted cases 3 Climate control 4 Desk-top cases 5 Subracks/ 19" chassis... 6

More information

TeSys contactors. TeSys D contactors. 690 V on a and c

TeSys contactors. TeSys D contactors. 690 V on a and c Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 0 V

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With

More information

Single Phase Motors Technical Datasheets

Single Phase Motors Technical Datasheets Single Phase Motors Technical Datasheets EN A dynamic, strong and ambitious Group: Orange1 Holding is an international renown Group, one of the most important European manufacturers of single-phase and

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

BETA Protecting Miniature Circuit Breakers

BETA Protecting Miniature Circuit Breakers Siemens AG 00 / Product overview / High-capacity range 000 A 0000 A 0000 A, high current 0000 A, universal current 000 A ka /0 Comfort range with plug-in terminal / Compact range +N in MW / Additional

More information

Type M4 - SON - SO - MS

Type M4 - SON - SO - MS 9. REV. Type M - SON - SO - MS Aircaps Tank venting and water excluding aircaps. For installation on service tank air pipes. Inerted void spaces and ballast tanks In order to maintain inert gas pressure

More information

TF Series Miniature Snap-acting Switches

TF Series Miniature Snap-acting Switches Features/Benefits Broad range of operating forces Ratings up to 21 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics Portable tools Specifications

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

X T O B P 1 6 B C 1 S

X T O B P 1 6 B C 1 S 9 Overload Relays XTOB, XTOT May 07 Contents Description Page Overload Relays XTOB, XTOT Selection................ 9 Product Selection.......... 95 Accessories............... 9 Technical Data and Specifications............

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC FEATURES Complying with IEC 60384-14 4 th edition Can pass 10 kv pulses (10 per polarity) Withstands 85 / 85 / 1000 h test Reduced

More information

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC FEATURES Complying with IEC 60384-14 4 th edition High reliability Vertical (inline) kinked or straight leads Singlelayer AC

More information

16 Input AC Block I/O Module

16 Input AC Block I/O Module 6 Input AC Module Cat. No. 79-6A0 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through

More information

Z7A. Load cells. Special features. Data sheet. Wiring code

Z7A. Load cells. Special features. Data sheet. Wiring code Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust

More information

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.

Ÿ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g. Ÿ 9-50-way std density Ÿ 15-78 way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g., 3W3, 5W5, 8W8) Ÿ Feed-through capacitor & pi filter constructions

More information

Power Distribution System SVS04

Power Distribution System SVS04 Power Distribution ystem V0 Description The V0 power distribution system for symmetrical DIN rail mounting is designed to distribute power from a switchmode power supply to or 8 channels. elective protection

More information

AVIKO 0230 G2 CATALOG ELECTRONIC PARTS

AVIKO 0230 G2 CATALOG ELECTRONIC PARTS AVIKO 00 G CATALOG ELECTRONIC PARTS LIST OF ELECTRONIC SPARE PARTS verze-008 SORTING SOLUTIONS LTD. CONTENT DESCRIPTION PAGE GENERAL SCHEME... EMS UNIT...- EDS UNIT...8- POWER UNIT...- INSPECTION POINT

More information

Power Distribution System SVS04

Power Distribution System SVS04 Power Distribution ystem V0 Description The V0 power distribution system for symmetrical DIN rail mounting is designed to distribute power from a switchmode power supply to or 8 channels. elective protection

More information

Pushbutton Units and Indicator Lights

Pushbutton Units and Indicator Lights Insert labels and insert caps Clear, illuminated and indicator lights can be fitted with insert labels and caps for identification purposes. These labels and caps are made of a semi-transparent molded

More information

American Zettler AZ742 RELAY Datasheet

American Zettler AZ742 RELAY Datasheet American Zettler AZ74 RELAY Datasheet http://www.manuallib.com/american-zettler/az74-relay-datasheet.html FEATURES Dielectric strength 000 Vrms Low height:.7 mm Epoxy sealed version available 0 Amp switching

More information

SUBMINIATURE MICROSWITCHES - STANDARD

SUBMINIATURE MICROSWITCHES - STANDARD 0/08 SUBMINIATURE MICROSWITCHES - STANDARD VD - 87 Flexible leaf snap-action mechanism with wiping contacts Ratings from 0.0 A Vc to (6) A 0 Va and / hp -0 Va ENEC and curus approved up to +0 C Housing

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

2.3. Rockers. Contents

2.3. Rockers. Contents . SVRSealed Vehicle SVRSealed Vehicle Rocker Contents Description SVRSealed Vehicle Above Panel Rocker Switch............... Below Panel Rocker Switch............... Technical Data and Specifications..........

More information

AC axial compact fan

AC axial compact fan ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information