GB-distribution boxes and enclosures
|
|
- Kelley Carroll
- 6 years ago
- Views:
Transcription
1 GBdistribution boxes and enclosures, polyester, to European Standards (ATEX) Features þ ATEXcertified þ BASEEFAcertified þ Large range of s including BARTEC, Weidmüller, Phoenix þ Different enclosure s þ External earth connection þ Extended ambient temperature range GBdistribution boxes and enclosures Description The GB box, both distribution box and empty enclosure, is manufactured of high impact resistance, glassfibre reinforced polyester SMC & DMC providing extraordinary stability and corrosion resistance. The standard enclosure consists of black, antistatic material. Other colours without antistatic characteristics are also available. All listed GB distribution boxes and empty enclosure have been tested and approved by the BASEEFA authorities according to the latest European Standards. These correspond to the requirements of the EC directive 94/9/EC (ATEX). Installation instructions The installer must make sure that the enclosure used is suitable for the corresponding field of application. This means that the material must be suitable and the required Ex protection type must correspond to the classification of the Ex area. Also the temperature class of the distribution box must meet the respective requirements. power dissipation for distribution boxes GB80 GB0 GB GB60 GB0 GB60 GB GB400/ GB400 Certification BAS98ATEX090X Empty enclosures approved for components GB9/090 GB960/6090 GB960/6090 GB9/0 GB94004/0 Certification BAS98ATEX089U BAS98ATEX089U BAS98ATEX089U Type GB80 GB0 GB GB60 GB0 GB60 GB GB400/ power dissipation at ambient temperatures of +40 C + C C Distribution box Empty Exenclosure EEx edistribution boxe GB... Enclosure GB9.../... Explosion protection Ex protection type BS EN 004, BS EN 009; 994 II G EEx e II T6, II G EEx e II II G EEx e II T6, II G EEx e II EN 08; 998 BS EN 004, BS EN 009; /0BCSB07/E Ambient temperature ranges 0 C to +40 C 0 C to +40 C (special temperature range on request) extended ambient temperature range extended ambient temperature range C to +6 C C to +6 C Technical data Material polyester, black, antistatic, polyester glassfibre reinforced, glassfibre reinforced, surface resistance < 0 9 Ω surface resistance > 0 9 Ω flame retardant: IEC 9., UL94VO flame retardant: IEC 9., UL94VO Colour/coating polyester, black, antistatic polyester Lid screws captive slotted or hexagon socket screw, captive slotted or hexagon socket screw, (other models on request) highquality stainless steel 6 highquality stainless steel 6 Standard seals captive silicone oring in featherkey and captive silicone oring in featherkey and keyway,,arrangement, protected against the keyway, arrangement, protected against the penetration of foreign matters, penetration of foreign matters, acc. to IP 66 (IEC 609/EN 609) acc. to IP 66 (IEC 609/EN 609) Mechanical resistance acc. to EN 004 impact energy < x 7 Nm impact energy < x 7 Nm Protection class acc. to 609/IEC 609 IP 66 IP 66 Power dissipation see selection chart (without BTB) see selection chart (without BTB) Certification EC model test certification BAS98ATEX090X EC model test certification BAS98ATEX089U Accessories XE earthing studs, ES earthing studs, XE earthing studs, ES earthing studs, WB wall bracket, PB pipe bracket WB wall bracket, PB pipe bracket FB highquality steel fixing bracket FB highquality steel fixing bracket /0
2 GBdistribution boxes Type GB80, polyester, to European Standards (ATEX) GB80 4 number of s 6 AKZ 4 4 AKZ 4 BK ( x pole) BK ( x pole) BK 4 ( x 4pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK 6 ( x 6pole) BARTEC Mini ( x pole) BARTEC Mini ( x pole) A V range mm² 0. to. 0. to. AKE 4 DFG MK (pole) DFG MK (pole) DFG MK (pole) DFG range mm² 0. to to 4.0 Fixing hole diameter mm. The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. View on sides Thread Side entries Position of hole Notes per side M 0 M Locknuts max. 7 mm A/C* þ EEx e plug elements can be fitted, if required *A/C = Across Corner /0BCSB07/E Order no.: GB80 /
3 GBdistribution boxes Type GB0, polyester, to European Standards (ATEX) GB0 Fixing hole diameter mm. number of s 7 AKZ 4 AKZ 4 BK ( x pole) BK ( x pole) BK 4 ( x 4pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK 6 ( x 6pole) BARTEC Mini ( x polig) BARTEC Mini ( x pole) BARTEC Mini ( x pole) to. 0. to. AKE 4 DFG MK (pole) DFG MK (pole) DFG MK (pole) DFG 0. to to 4.0 The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. View on sides Thread Side entries Position of hole Notes per side M 0 M M, M (or 4 m, M) Locknuts max. 7 mm A/C* þ EEx e plug elements can be fitted, if required *A/C = Across Corner /0BCSB07/E / Order no.: GB0
4 GBdistribution boxes Type GB, polyester, to European Standards (ATEX) Seite Seite D number of s 0 SAK. 8 SAK 4 6 SAK 6N SAK 0 WDU. 9 WDU 4 9 WDU 6 6 WDU 0 6 WDU 6 WDU BK ( x pole) BK 4 ( x 4 pole) BK 6 ( x 6pole) BK ( x pole) MK 6/6 ( x 6pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. GB 0. to. 0. to 6.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0 EK 0 WPE. WPE 0 WPE BET BET. to 0.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to to View on sides The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries Position Notes per side of holes View on sides (viewed from side C) M 0 M M M, M U, 4L, L Not with ECP fitted and locknuts max. 7 mm A/C* M Not when strip fitted M Not when QS fitted M M, M Locknut max. 40 mm A/C* M M Entries on sides are directly opposite each other /0BCSB07/4E View on sides F Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible. *A/C = Across Corner Order no.: GB /
5 GBdistribution boxes Type GB0,polyester, to European Standards (ATEX) GB /0BCSB07/E View on sides View on sides (viewed from side C) Entries on sides are directly opposite each other. View on sides F /4 number of s SAK. 0 SAK 4 9 SAK 6N 9 SAK 0 WDU. 9 WDU 4 0 WDU 6 7 WDU 0 7 WDU 6 4 WDU BK ( x pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK ( x pole) MK 6/6 ( x 6pole) BTB 4 ( x 4pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) BTB 6 ( x 6pole) þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned to. 0. to 6.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0* EK 0 WPE. WPE 0 WPE BET BET. to 0.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0* 0. to 6.0* Thread Side entries Position Notes per side of holes M, 8M, 9M, M 0 4 M, M, 0M, M M, 6M, 7M, M, M M oder M Not when QS earth bar fitted M 4M, M M, 0M, M M 4M, M Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible. Order no.: GB0
6 GBdistribution boxes Type GB60, polyester, to European Standards (ATEX) GB60 number of s SAK. 4 SAK 4 SAK 6N 8 SAK 0 7 SAK 6 7 WDU. WDU 4 WDU 6 9 WDU 0 9 WDU 6 WDU BK ( x pole) BK 4 ( x 4pole) to. 0. to 6.0. to to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 WPE. WPE 0 WPE. to to 6.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 4 BK 6 ( x 6pole) BK ( x pole) x BK 4 + x BK 7 BET 0. to 6.0* BTB 4 ( x 4pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) to 6.0* BET 0. to 6.0* BTB 6 ( x 6pole) þ A maximum of earth bars type QS4 may be supplied. þ Alternative types are available. View on sides View on sides The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries Position Note per side of holes M 0 M, 4M, M M, M Not when QS4 earth bar fitted M M M, M Not when QS4 earth bar fitted M, M M M, M Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible also /0BCSB07/6E View on sides F Special side entry positions Thread Side entries per side Position of holes M 0 6 U, L, su, sl, su, sl su, sl, su, sl M 0 + M 4 x M0 x M, M x M0 su, sl M 0 + M x M sm þ Single M 0 entry in the lid is possible. Order no.: GB60 /
7 GBdistribution boxes Type GB60,polyester, to European Standards (ATEX) GB60 number of s 7 SAK. SAK. SAK. SAK 4 8 SAK 4 0 SAK 4 SAK 6N SAK 6N 4 SAK 6N SAK 0 8 SAK 0 SAK 6 SAK 6 7 WDU. WDU 4 WDU 6 0 WDU 0 9 WDU 6 6 WDU to. 0. to 6.0. to to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 WPE. WPE 0 WPE. to to 6.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 View on sides View on sides þ A maximum of earth bars type QS4 may be supplied. þ Alternative types are available. The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries per side Position of holes M, M, M, 6M, 7M M 0 0 U, U, U, 6U, 7U, L, L, L, 6L, 7L M, M M, 4M, M M 4 sm, sm, 8sM, 9sM M, M M M, 4M, M /0BCSB07/7E View on sides F Special rear entry positions Thread Side entries per side Position of holes M 0 F 8 F, F, F, 4F, F, 6F, 7F, 8F M F 9F þ Single M 0 entry in the lid is possible also. Order no.: GB60 /6
8 GBdistribution boxes Type GB, polyester, to European Standards (ATEX) number of s Number of rails GB 4 SAK. SAK. 6 SAK. 0 SAK 4 44 SAK 4 60 SAK 4 9 SAK 6N 4 SAK 6N 48 SAK 6N 7 SAK 0 6 SAK 0 SAK 6 8 SAK N WDU. 9 WDU 4 0 WDU 6 4 WDU 0 4 WDU 6 9 WDU þ A maximum of earth connection bars type QS9 may be supplied. þ Alternative types are available to. 0. to 6.0. to 0.0. to 0.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE 0, bis 4,0. to to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to /0BCSB07/8E View on sides View on sides The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned or fitted with a single diagonally mounted strip. Thread Side entries per side Position of holes M 0 M M M 40 M 0 M, 4M, M, 0M, M 0 U, 4U, U, 0U, U, L, 4L, L, 0L, L 4 M, M, 6M, 7M 8 U, U, 6U, 7U, L, L, 6L, 7L 4 M, M, 8M, 9M M, 6M, 7M M, 6M, 7M 4M, M M, 6M, 7M 4M, M M M Order no.: GB /7
9 GBdistribution boxes Type GB400, polyester, to European Standards (ATEX) GB400 number of s SAK. 74 SAK. 08 SAK. 7 SAK 4 9 SAK 4 0 SAK 4 6 SAK 6N 6 SAK 6N 84 SAK 6N SAK 0 SAK 0 0 SAK 6 9 SAK N SAK 70 WDU, 6 WDU 4 6 WDU 6 0 WDU 0 9 WDU 6 WDU Number of rails þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. 0. to. 0. to 6.0. to to 6.0. bis.0.0 to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE. to to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned or connected with a single diagonally mounted strip /0BCSB07/9E View on sides and sides /8 Thread Side entries per side Position of holes 8 M, M, 6M, 7M, M, M, 6M, 7M M 0 and U, U, 6U, 7U, U, U, 6U, 7U, 6 L, L, 6L, 7L, L, L, 6L, 7L M and 7 M, 4M, M, 0M, M, 6M, 7M M and M, 8M, 9M, 4M, M M 40 and M, 8M, 9M, 4M, M M M 0 and 4sM, sm oder M, 4sM oder M, sm Order no.: GB400
10 GBdistribution boxes, Type GB400/, polyester, to European Standards (ATEX) GB400/ 4 number of s SAK. 8 SAK 4 8 SAK 6N 6 SAK 0 SAK 6 4 SAK N WDU. 8 WDU 4 8 WDU 6 4 WDU 0 4 WDU 6 9 WDU Number of rails range 0. to. 0. to to to 6.0. to.0 0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE range to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 þ A maximum of earth bars type QS9 may be supplied. þ Alternative types are available. The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned /0BCSB07/0E View on sides View on sides Thread Side entries Position of holes per side 8 M, M, 6M, 7M, M, M, 6M, 7M 6 U, L, U, L, 6U, 6L, 7U, 7L, U, L, U, L,6U, 6L,7U,7L M 0 4 M, M, 6M, 7M 8 U, L, U, L, 6U, 6L, 7U, 7L M M M 40 M 0 7 M, 4M, M, 0M, M, 6M, 7M M, 8M, 9M, 4M, M M, 8M, 9M, 4M, M M M, 6M, 7M 4M, M 4M, M M Order no.: GB400/ /9
I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I
I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX
More informationEX-EMERGENCY LIGHT FITTINGS
EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing
More informationE X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S
E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND
More informationExplosion-protected recessed ceiling LED-light and fluorescent light fittings
.7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX
More informationInstallation Equipment
Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More information4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)
.2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof
More information2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22
.1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk
More information4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure
.13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in
More informationEx-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)
Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationEx-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments
.13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications
More informationChapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar
Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted
More information2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)
.1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More information4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)
.3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationOverload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011
SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationThermal-Magnetic Circuit Breaker 2210-T2...
Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively
More informationCDS. high density spring connection
CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this
More informationField mounted Temperature Transmitter TF212/TF212-Ex
Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote
More informationEx floating switches and Ex immersion probes
Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466
More informationType UB1 Load Cell. Option Stainless steel cable gland
Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series
Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation
TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)
More informationSANMUR CONTROLS PVT. LTD.
Decide with confidence NMUR CONTROLS NMUR CONTROLS PVT. LTD. An ISO 900:008 Certified Company The name NMUR has been synonymous with reliability and quality in terms of products, services and systems integration.
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More information2D - STRIP ANCHOR LIFTING SYSTEM
2D - STRIP ANCHOR LIFTING SYSTEM WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW LIFTING CLUTCHES AND TRANSPORT ANCHOR SA-B SA-ST SA-TTU UNIVERSAL
More informationMotor Protection Circuit Breaker Series 8146/5-V27
> For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationxce series & xjf EXPLOSIONPROOF ENCLOSURES EXPLOSIONPRROOF ENCLOSURES CERTIFICATIONS STANDARD FEATURES DESIGN OPTIONS MATERIAL ADALET.
EXPLOSIONPROOF XCE: Explosionproof Control Enclosures XCEX: Flameproof Control Enclosures XCEQ: Explosionproof Quad-Lead Control Enclosures XJF: Explosionproof Junction Boxes STANDARD FEATURES standard
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationBettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.
Bettis RGS F-Series Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators Output Torques to 500,000 in-lb (56,492 N m) Ductile Iron or Stainless-Steel Construction Temperatures from
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationEX-FLUORESCENT LIGHT FITTINGS
EX-FLUORESCENT LIGHT FITTINGS Cooper Crouse-Hinds 00 - all rights reserved EX-LIGHT FITTING ellk... MAIN FEATURES.0 EX-LIGHT FITTING ellk... EX-POLE MOUNTED LIGHT FITTING ellm....0. EX-EMERGENCY LIGHT
More informationLoad Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction
Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260
More informationVX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity
VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing
More informationI Ex d/e Switch- and Control-Equipment I
I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units
More informationSolenoid valves Type EVUL
Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.
More informationEX-CONTROL AND DISTRIBUTION SYSTEMS
EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES
More information5SJ4...-.HG Circuit Breakers to IEC and UL 489
Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is
More informationMade in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1
Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE
More informationSingle point load cells
SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationBody (Black) O-ring. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).
Antistatic One-touch Fittings ubing: etric Size/Connection hread:, Rc, G, NP, NPF Series RoS One-touch fitting with antistatic prevention. One-touch IN/OU connection. Possible to use from vacuum ( 0 kpa.
More informationø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.
Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type
More informationMR medium rating busbar
technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationHARTING D-Sub Selection Guide
HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,
More information2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm
1 E X - F L U O R E S C E N T L I G H T F I T T I N G S 2 3 6 EX-LIGHT FITTING ellk 2... MAIN FEATURES EX-LIGHT FITTING ellk 2... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 2... EX-EMERGENCY LIGHT
More informationHELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN
Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationProtected. Main specifications. Additional specifications. Product adaptations
Protected 83 06 Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard 83 06 0 stable lever positions 83 06 4 stable plunger
More information40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES
DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...
More informationSection Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series
Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B
More informationv = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes
Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air
More informationExchangeable measuring insets SensyTemp TSA101
Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular
More informationTechnical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS
CONCRETE / SOLID STONE USAGE 1. AREAS OF APPLICATION Heavy load-carrying attachments in solid stone, concrete, porous concrete and light concrete Suitable for attachment points close to the edge, since
More informationCapacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z
Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationE X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S
1 E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 2 4 5 6 8 EX- CEILING LIGHT FITTINGS EX- PENDANT LIGHT FITTINGS 4.41 4. EX- FLOODLIGHTS EX- VESSEL LIGHT FITTING
More informationTHE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE
July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the
More informationBody (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).
Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationOur Other Range Of Products. Various Types of Cable Clamps
Our Other Range Of Products Brass Terminal Bars & Blocks Brass & Copper Earthing Accessories Brass & G. I. Conduit Fittings Brass Glands Various Types of Clamps Din Rail 8 Our Other Range Of Products Brass
More informationSerie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18
erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves
More informationISEmax CAS40D. Technical Information
Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor
More informationUniversal limit switches
SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph
ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The
More informationSensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty
Sensor/actuator boxes M distributor with metal thread, heavy-duty Notes: Suitable for SPEEDCON and M standard, see page:. For further technical data, see: www.phoenixcontact.net/catalog With a master cable
More informationConstruction and application of resistance thermometers
Page 1/15 Construction and application of resistance thermometers Temperature-dependent resistance The variation of the electrical resistance of metals with temperature is very often employed for the electrical
More informationAntistatic One-touch Fittings. Packing. Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0MPa.
Antistatic One-touch Fittings Series KA One-touch loading and unloading Possible to use in vacuum (ax. 0kPa) Can be used in copper-free application Flame resistance (UL- standard, V-0) Surface resistance
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationCFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying
CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationCalio-Therm NC Type Series Booklet
High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More information