GB-distribution boxes and enclosures

Size: px
Start display at page:

Download "GB-distribution boxes and enclosures"

Transcription

1 GBdistribution boxes and enclosures, polyester, to European Standards (ATEX) Features þ ATEXcertified þ BASEEFAcertified þ Large range of s including BARTEC, Weidmüller, Phoenix þ Different enclosure s þ External earth connection þ Extended ambient temperature range GBdistribution boxes and enclosures Description The GB box, both distribution box and empty enclosure, is manufactured of high impact resistance, glassfibre reinforced polyester SMC & DMC providing extraordinary stability and corrosion resistance. The standard enclosure consists of black, antistatic material. Other colours without antistatic characteristics are also available. All listed GB distribution boxes and empty enclosure have been tested and approved by the BASEEFA authorities according to the latest European Standards. These correspond to the requirements of the EC directive 94/9/EC (ATEX). Installation instructions The installer must make sure that the enclosure used is suitable for the corresponding field of application. This means that the material must be suitable and the required Ex protection type must correspond to the classification of the Ex area. Also the temperature class of the distribution box must meet the respective requirements. power dissipation for distribution boxes GB80 GB0 GB GB60 GB0 GB60 GB GB400/ GB400 Certification BAS98ATEX090X Empty enclosures approved for components GB9/090 GB960/6090 GB960/6090 GB9/0 GB94004/0 Certification BAS98ATEX089U BAS98ATEX089U BAS98ATEX089U Type GB80 GB0 GB GB60 GB0 GB60 GB GB400/ power dissipation at ambient temperatures of +40 C + C C Distribution box Empty Exenclosure EEx edistribution boxe GB... Enclosure GB9.../... Explosion protection Ex protection type BS EN 004, BS EN 009; 994 II G EEx e II T6, II G EEx e II II G EEx e II T6, II G EEx e II EN 08; 998 BS EN 004, BS EN 009; /0BCSB07/E Ambient temperature ranges 0 C to +40 C 0 C to +40 C (special temperature range on request) extended ambient temperature range extended ambient temperature range C to +6 C C to +6 C Technical data Material polyester, black, antistatic, polyester glassfibre reinforced, glassfibre reinforced, surface resistance < 0 9 Ω surface resistance > 0 9 Ω flame retardant: IEC 9., UL94VO flame retardant: IEC 9., UL94VO Colour/coating polyester, black, antistatic polyester Lid screws captive slotted or hexagon socket screw, captive slotted or hexagon socket screw, (other models on request) highquality stainless steel 6 highquality stainless steel 6 Standard seals captive silicone oring in featherkey and captive silicone oring in featherkey and keyway,,arrangement, protected against the keyway, arrangement, protected against the penetration of foreign matters, penetration of foreign matters, acc. to IP 66 (IEC 609/EN 609) acc. to IP 66 (IEC 609/EN 609) Mechanical resistance acc. to EN 004 impact energy < x 7 Nm impact energy < x 7 Nm Protection class acc. to 609/IEC 609 IP 66 IP 66 Power dissipation see selection chart (without BTB) see selection chart (without BTB) Certification EC model test certification BAS98ATEX090X EC model test certification BAS98ATEX089U Accessories XE earthing studs, ES earthing studs, XE earthing studs, ES earthing studs, WB wall bracket, PB pipe bracket WB wall bracket, PB pipe bracket FB highquality steel fixing bracket FB highquality steel fixing bracket /0

2 GBdistribution boxes Type GB80, polyester, to European Standards (ATEX) GB80 4 number of s 6 AKZ 4 4 AKZ 4 BK ( x pole) BK ( x pole) BK 4 ( x 4pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK 6 ( x 6pole) BARTEC Mini ( x pole) BARTEC Mini ( x pole) A V range mm² 0. to. 0. to. AKE 4 DFG MK (pole) DFG MK (pole) DFG MK (pole) DFG range mm² 0. to to 4.0 Fixing hole diameter mm. The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. View on sides Thread Side entries Position of hole Notes per side M 0 M Locknuts max. 7 mm A/C* þ EEx e plug elements can be fitted, if required *A/C = Across Corner /0BCSB07/E Order no.: GB80 /

3 GBdistribution boxes Type GB0, polyester, to European Standards (ATEX) GB0 Fixing hole diameter mm. number of s 7 AKZ 4 AKZ 4 BK ( x pole) BK ( x pole) BK 4 ( x 4pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK 6 ( x 6pole) BARTEC Mini ( x polig) BARTEC Mini ( x pole) BARTEC Mini ( x pole) to. 0. to. AKE 4 DFG MK (pole) DFG MK (pole) DFG MK (pole) DFG 0. to to 4.0 The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. View on sides Thread Side entries Position of hole Notes per side M 0 M M, M (or 4 m, M) Locknuts max. 7 mm A/C* þ EEx e plug elements can be fitted, if required *A/C = Across Corner /0BCSB07/E / Order no.: GB0

4 GBdistribution boxes Type GB, polyester, to European Standards (ATEX) Seite Seite D number of s 0 SAK. 8 SAK 4 6 SAK 6N SAK 0 WDU. 9 WDU 4 9 WDU 6 6 WDU 0 6 WDU 6 WDU BK ( x pole) BK 4 ( x 4 pole) BK 6 ( x 6pole) BK ( x pole) MK 6/6 ( x 6pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. GB 0. to. 0. to 6.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0 EK 0 WPE. WPE 0 WPE BET BET. to 0.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to to View on sides The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries Position Notes per side of holes View on sides (viewed from side C) M 0 M M M, M U, 4L, L Not with ECP fitted and locknuts max. 7 mm A/C* M Not when strip fitted M Not when QS fitted M M, M Locknut max. 40 mm A/C* M M Entries on sides are directly opposite each other /0BCSB07/4E View on sides F Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible. *A/C = Across Corner Order no.: GB /

5 GBdistribution boxes Type GB0,polyester, to European Standards (ATEX) GB /0BCSB07/E View on sides View on sides (viewed from side C) Entries on sides are directly opposite each other. View on sides F /4 number of s SAK. 0 SAK 4 9 SAK 6N 9 SAK 0 WDU. 9 WDU 4 0 WDU 6 7 WDU 0 7 WDU 6 4 WDU BK ( x pole) BK 4 ( x 4pole) BK 6 ( x 6pole) BK ( x pole) MK 6/6 ( x 6pole) BTB 4 ( x 4pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) BTB 6 ( x 6pole) þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. The number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned to. 0. to 6.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0* EK 0 WPE. WPE 0 WPE BET BET. to 0.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 0. to 6.0* 0. to 6.0* Thread Side entries Position Notes per side of holes M, 8M, 9M, M 0 4 M, M, 0M, M M, 6M, 7M, M, M M oder M Not when QS earth bar fitted M 4M, M M, 0M, M M 4M, M Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible. Order no.: GB0

6 GBdistribution boxes Type GB60, polyester, to European Standards (ATEX) GB60 number of s SAK. 4 SAK 4 SAK 6N 8 SAK 0 7 SAK 6 7 WDU. WDU 4 WDU 6 9 WDU 0 9 WDU 6 WDU BK ( x pole) BK 4 ( x 4pole) to. 0. to 6.0. to to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 WPE. WPE 0 WPE. to to 6.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 4 BK 6 ( x 6pole) BK ( x pole) x BK 4 + x BK 7 BET 0. to 6.0* BTB 4 ( x 4pole) BTB 4 ( x 4pole) BTB 6 ( x 6pole) to 6.0* BET 0. to 6.0* BTB 6 ( x 6pole) þ A maximum of earth bars type QS4 may be supplied. þ Alternative types are available. View on sides View on sides The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries Position Note per side of holes M 0 M, 4M, M M, M Not when QS4 earth bar fitted M M M, M Not when QS4 earth bar fitted M, M M M, M Special rear entry positions Thread Side entries per side Position of holes M 0 F 4 F, F, F, 4F þ Single M 0 entry in the lid is possible also /0BCSB07/6E View on sides F Special side entry positions Thread Side entries per side Position of holes M 0 6 U, L, su, sl, su, sl su, sl, su, sl M 0 + M 4 x M0 x M, M x M0 su, sl M 0 + M x M sm þ Single M 0 entry in the lid is possible. Order no.: GB60 /

7 GBdistribution boxes Type GB60,polyester, to European Standards (ATEX) GB60 number of s 7 SAK. SAK. SAK. SAK 4 8 SAK 4 0 SAK 4 SAK 6N SAK 6N 4 SAK 6N SAK 0 8 SAK 0 SAK 6 SAK 6 7 WDU. WDU 4 WDU 6 0 WDU 0 9 WDU 6 6 WDU to. 0. to 6.0. to to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 WPE. WPE 0 WPE. to to 6.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 View on sides View on sides þ A maximum of earth bars type QS4 may be supplied. þ Alternative types are available. The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned. Thread Side entries per side Position of holes M, M, M, 6M, 7M M 0 0 U, U, U, 6U, 7U, L, L, L, 6L, 7L M, M M, 4M, M M 4 sm, sm, 8sM, 9sM M, M M M, 4M, M /0BCSB07/7E View on sides F Special rear entry positions Thread Side entries per side Position of holes M 0 F 8 F, F, F, 4F, F, 6F, 7F, 8F M F 9F þ Single M 0 entry in the lid is possible also. Order no.: GB60 /6

8 GBdistribution boxes Type GB, polyester, to European Standards (ATEX) number of s Number of rails GB 4 SAK. SAK. 6 SAK. 0 SAK 4 44 SAK 4 60 SAK 4 9 SAK 6N 4 SAK 6N 48 SAK 6N 7 SAK 0 6 SAK 0 SAK 6 8 SAK N WDU. 9 WDU 4 0 WDU 6 4 WDU 0 4 WDU 6 9 WDU þ A maximum of earth connection bars type QS9 may be supplied. þ Alternative types are available to. 0. to 6.0. to 0.0. to 0.0. to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE 0, bis 4,0. to to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to /0BCSB07/8E View on sides View on sides The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned or fitted with a single diagonally mounted strip. Thread Side entries per side Position of holes M 0 M M M 40 M 0 M, 4M, M, 0M, M 0 U, 4U, U, 0U, U, L, 4L, L, 0L, L 4 M, M, 6M, 7M 8 U, U, 6U, 7U, L, L, 6L, 7L 4 M, M, 8M, 9M M, 6M, 7M M, 6M, 7M 4M, M M, 6M, 7M 4M, M M M Order no.: GB /7

9 GBdistribution boxes Type GB400, polyester, to European Standards (ATEX) GB400 number of s SAK. 74 SAK. 08 SAK. 7 SAK 4 9 SAK 4 0 SAK 4 6 SAK 6N 6 SAK 6N 84 SAK 6N SAK 0 SAK 0 0 SAK 6 9 SAK N SAK 70 WDU, 6 WDU 4 6 WDU 6 0 WDU 0 9 WDU 6 WDU Number of rails þ A maximum of earth bars type QS may be supplied. þ Alternative types are available. 0. to. 0. to 6.0. to to 6.0. bis.0.0 to to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE. to to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned or connected with a single diagonally mounted strip /0BCSB07/9E View on sides and sides /8 Thread Side entries per side Position of holes 8 M, M, 6M, 7M, M, M, 6M, 7M M 0 and U, U, 6U, 7U, U, U, 6U, 7U, 6 L, L, 6L, 7L, L, L, 6L, 7L M and 7 M, 4M, M, 0M, M, 6M, 7M M and M, 8M, 9M, 4M, M M 40 and M, 8M, 9M, 4M, M M M 0 and 4sM, sm oder M, 4sM oder M, sm Order no.: GB400

10 GBdistribution boxes, Type GB400/, polyester, to European Standards (ATEX) GB400/ 4 number of s SAK. 8 SAK 4 8 SAK 6N 6 SAK 0 SAK 6 4 SAK N WDU. 8 WDU 4 8 WDU 6 4 WDU 0 4 WDU 6 9 WDU Number of rails range 0. to. 0. to to to 6.0. to.0 0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 EK 0 EK 6 EK WPE. WPE 0 WPE range to to.0. to.. to 4.0. to 6.0. to 0.0. to 6.0. to.0 þ A maximum of earth bars type QS9 may be supplied. þ Alternative types are available. The maximum number of s listed above depends on the maximum conductor and maximum. At least one earth must be supplied. The enclosure can be mounted with the strip horizontally or vertically aligned /0BCSB07/0E View on sides View on sides Thread Side entries Position of holes per side 8 M, M, 6M, 7M, M, M, 6M, 7M 6 U, L, U, L, 6U, 6L, 7U, 7L, U, L, U, L,6U, 6L,7U,7L M 0 4 M, M, 6M, 7M 8 U, L, U, L, 6U, 6L, 7U, 7L M M M 40 M 0 7 M, 4M, M, 0M, M, 6M, 7M M, 8M, 9M, 4M, M M, 8M, 9M, 4M, M M M, 6M, 7M 4M, M 4M, M M Order no.: GB400/ /9

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets CES System Series 8, 88, 8, 881 Te plugs and sockets in te CES system comply wit CEE publication 1 and European standards EN 0 01. Te small 1 A socket as switcing

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

Installation Equipment

Installation Equipment Installation Switches made of Moulded Plastic 800 8 Junction Boxes made of Polyester Resin, with Sheath Terminals 80 8 made of Polyester Resin, with... 8 Sheath Terminals 88 8 Terminal Boxes made of Polyester

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22) .3 Ex-Pendant light fittings AB 5 / SPG 1N / AB 51 / EVI 2 / EVI 5 / EV35 LED (Zone 1, 2, 21, 2 The pendant light fitting series for a wide variety of applications The explosion-protected pendant light

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011 SIRIUS 3RU1 Thermal Overview 1 2 7 3 4 6 "Increased safety" type of EEx e according to ATEX directive 94/9/EC The 3RU11 thermal overload relays are suitable for the overload of explosion-proof motors with

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8. TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Field mounted Temperature Transmitter TF212/TF212-Ex

Field mounted Temperature Transmitter TF212/TF212-Ex Data Sheet Field mounted Temperature Transmitter TF/TF-Ex PROFIBUS PA, Pt 00 (RTD), Thermocouples, or independent channels Input Resistance thermometer (,, -wire circuit) Thermocouples Resistance remote

More information

Ex floating switches and Ex immersion probes

Ex floating switches and Ex immersion probes Ex floating switches and Ex immersion probes Controlling devices with ball-operated microswitch, for signalling or regulation of liquid levels Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466

More information

Type UB1 Load Cell. Option Stainless steel cable gland

Type UB1 Load Cell. Option Stainless steel cable gland Type UB1 Load Cell IP68 APPROVED Product Description Type UB1 is a stainless steel universal load cell which allows for tension and compression loading. Its complete hermetic sealing makes it suitable

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method)

More information

SANMUR CONTROLS PVT. LTD.

SANMUR CONTROLS PVT. LTD. Decide with confidence NMUR CONTROLS NMUR CONTROLS PVT. LTD. An ISO 900:008 Certified Company The name NMUR has been synonymous with reliability and quality in terms of products, services and systems integration.

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

2D - STRIP ANCHOR LIFTING SYSTEM

2D - STRIP ANCHOR LIFTING SYSTEM 2D - STRIP ANCHOR LIFTING SYSTEM WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW LIFTING CLUTCHES AND TRANSPORT ANCHOR SA-B SA-ST SA-TTU UNIVERSAL

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

xce series & xjf EXPLOSIONPROOF ENCLOSURES EXPLOSIONPRROOF ENCLOSURES CERTIFICATIONS STANDARD FEATURES DESIGN OPTIONS MATERIAL ADALET.

xce series & xjf EXPLOSIONPROOF ENCLOSURES EXPLOSIONPRROOF ENCLOSURES CERTIFICATIONS STANDARD FEATURES DESIGN OPTIONS MATERIAL ADALET. EXPLOSIONPROOF XCE: Explosionproof Control Enclosures XCEX: Flameproof Control Enclosures XCEQ: Explosionproof Quad-Lead Control Enclosures XJF: Explosionproof Junction Boxes STANDARD FEATURES standard

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev. Bettis RGS F-Series Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators Output Torques to 500,000 in-lb (56,492 N m) Ductile Iron or Stainless-Steel Construction Temperatures from

More information

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to

More information

EX-FLUORESCENT LIGHT FITTINGS

EX-FLUORESCENT LIGHT FITTINGS EX-FLUORESCENT LIGHT FITTINGS Cooper Crouse-Hinds 00 - all rights reserved EX-LIGHT FITTING ellk... MAIN FEATURES.0 EX-LIGHT FITTING ellk... EX-POLE MOUNTED LIGHT FITTING ellm....0. EX-EMERGENCY LIGHT

More information

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction Siemens AG 2018 /2 Introduction / Mounting components / Introduction /4 Single point load cells /4 Overview /5 SIWAREX WL260 SP-S AA /5 - Load cell /6 SIWAREX WL260 SP-S AB /6 - Load cell /7 SIWAREX WL260

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

I Ex d/e Switch- and Control-Equipment I

I Ex d/e Switch- and Control-Equipment I I Ex d/e Switch- and Control-Equipment I Customised enclosure, covered by Type Examination Certificates, can be individually combined from CEAG s numerous built-in components. Furthermore control units

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

EX-CONTROL AND DISTRIBUTION SYSTEMS

EX-CONTROL AND DISTRIBUTION SYSTEMS EX-CONTROL AND DISTRIBUTION SYSTEMS Cooper Crouse-Hinds 00 - all rights reserved EX-DISTRIBUTION IN PLASTIC DESIGN. EX-DISTRIBUTION IN STAINLESS STEEL EX-D BUILT-IN COMPONENTS.. 9 EX-E EMPTY ENCLOSURES

More information

5SJ4...-.HG Circuit Breakers to IEC and UL 489

5SJ4...-.HG Circuit Breakers to IEC and UL 489 Siemens AG 009 5SJ...-.HG Circuit Breakers to IEC and UL 89 BETA Low-Voltage Circuit Protection Compliance with industry standards is a must in today's manufacturing environment. Worldwide acceptance is

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems

More information

Body (Black) O-ring. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent). Antistatic One-touch Fittings ubing: etric Size/Connection hread:, Rc, G, NP, NPF Series RoS One-touch fitting with antistatic prevention. One-touch IN/OU connection. Possible to use from vacuum ( 0 kpa.

More information

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke. Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm

2.20. EX-LIGHT FITTING ellk MAIN FEATURES EX-LIGHT FITTING ellk EX-POLE MOUNTED LIGHT FITTING ellm 1 E X - F L U O R E S C E N T L I G H T F I T T I N G S 2 3 6 EX-LIGHT FITTING ellk 2... MAIN FEATURES EX-LIGHT FITTING ellk 2... 2.20 2.12 7 EX-POLE MOUNTED LIGHT FITTING ellm 2... EX-EMERGENCY LIGHT

More information

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide

More information

Protected. Main specifications. Additional specifications. Product adaptations

Protected. Main specifications. Additional specifications. Product adaptations Protected 83 06 Double break switching Options for operation in stable positions Choice of actuators and fixing positions Main specifications Standard 83 06 0 stable lever positions 83 06 4 stable plunger

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B

More information

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes Examples of Application Flow measurements also in hazardous locations X zone 0 or zone 1 in clean rooms in air

More information

Exchangeable measuring insets SensyTemp TSA101

Exchangeable measuring insets SensyTemp TSA101 Contents Data Sheet Exchangeable measuring insets SensyTemp TSA101 for resistance thermometers and thermocouples Structure of electrical thermometers - Exchangeability during operation based on modular

More information

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS CONCRETE / SOLID STONE USAGE 1. AREAS OF APPLICATION Heavy load-carrying attachments in solid stone, concrete, porous concrete and light concrete Suitable for attachment points close to the edge, since

More information

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Technical Information TI 271F/00/en Operating Instructions 017182-1000 Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z Transmitters for capacitance probes Application The electronic inserts

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S

E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 1 E X - C E I L I N G, P E N D A N T L I G H T F I T T I N G S A N D F L O O D L I G H T S 2 4 5 6 8 EX- CEILING LIGHT FITTINGS EX- PENDANT LIGHT FITTINGS 4.41 4. EX- FLOODLIGHTS EX- VESSEL LIGHT FITTING

More information

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN PANEL BOARDS ADDRESSED TO HAZARDOUS AREAS - PART THREE July 04 THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE In this third part. we want to speak about how important is the correct sizing of the

More information

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent). Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Our Other Range Of Products. Various Types of Cable Clamps

Our Other Range Of Products. Various Types of Cable Clamps Our Other Range Of Products Brass Terminal Bars & Blocks Brass & Copper Earthing Accessories Brass & G. I. Conduit Fittings Brass Glands Various Types of Clamps Din Rail 8 Our Other Range Of Products Brass

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

ISEmax CAS40D. Technical Information

ISEmax CAS40D. Technical Information Technical Information ISEmax CAS40D Online measurement of nutrient parameters Ion-selective electrodes for the continuous measurement of ammonium, nitrate and other ions Application The ion-selective sensor

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph ABB MEASUREMENT & ANALYTICS DATA SHEET PGC5000 Temperature programmed gas chromatograph 2 P G C 5 0 0 0 T E M P E R AT U R E P R O G R A M M E D D S/ P G C 5 0 0 0 T P - E N Measurement & Analytics The

More information

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty

Sensor/actuator cabling PLUSCON field Sensor/actuator boxes M12 distributor with metal thread, heavy-duty Sensor/actuator boxes M distributor with metal thread, heavy-duty Notes: Suitable for SPEEDCON and M standard, see page:. For further technical data, see: www.phoenixcontact.net/catalog With a master cable

More information

Construction and application of resistance thermometers

Construction and application of resistance thermometers Page 1/15 Construction and application of resistance thermometers Temperature-dependent resistance The variation of the electrical resistance of metals with temperature is very often employed for the electrical

More information

Antistatic One-touch Fittings. Packing. Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0MPa.

Antistatic One-touch Fittings. Packing. Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0MPa. Antistatic One-touch Fittings Series KA One-touch loading and unloading Possible to use in vacuum (ax. 0kPa) Can be used in copper-free application Flame resistance (UL- standard, V-0) Surface resistance

More information

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling

More information

W 30 Photoelectric proximity switches: Clear signals even with low remission

W 30 Photoelectric proximity switches: Clear signals even with low remission W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,

More information

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.

More information

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying

CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying CFC, HCFC free, GWP zero thermal insulation in the form of tubes, sheets, coils and self-adhesive tape, a Flexible Elastomeric Foam product complying with the European standard EN. EUROBATEX is a closed

More information

Surface-mounting Thermostats ATH Type Series

Surface-mounting Thermostats ATH Type Series Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments

More information

Calio-Therm NC Type Series Booklet

Calio-Therm NC Type Series Booklet High-efficiency Drinking Water Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information