Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

Size: px
Start display at page:

Download "Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series"

Transcription

1 Section > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series 22 23

2 > CABLE GLANDS WITH DEVICE TO PREVENT ANY UNSCREWING UNION Series B (*) IP8 (1 bar) C A in mm A B C ø fixing hole cable size ø spanner size thread length Spanner coupler (N/m) nut seal Fixing TYPE A (metric HD ) With nut Heavy duty RAL 00 grey Without nut With diaphram and nut With diaphram without nut Locknuts Heavy duty RAL 00 grey Seals PG / / / / / / / /00 PG / / / / / / / /00 PG11 22, / / / / / / / /00 PG THREAD PG, PG1 PG21 PG , , / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /00 PG3, , / / / / / / / /00 PG2, / / / / / / / /00 PG / / / / / / / /00 Mx / / / / / / / /00 M1x / / / / / / / /00 METRIC THREAD M20x1. M2x1. Mx1. M0x , 9 1, 11, / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /00 M0x , 80.0 / / / / / / / /00 M3x , 80.3 / / /0 80. / / / / /00 1/ / /00 3/ / /00 GAS THREAD 1/2 /8 3/ 1 1.1/8 1.1/ , 3,, , , /00 2/300 2/00 2/30 / / / /00 2/300 2/00 2/30 / / /0 (*) Cable glands are provided without gasket: STANDARD version: HEAVY DUTY version or IP8 (1 bar) if installed with corresponding seal. CABLE GLAND TABLE: METRIC/PG/GAS M3 M0 M0 PG8 M PG2 M2 PG3 M20 PG29 GAS 2 M1 PG21 GAS 1.1/2 M PG1 GAS 1.1/8 PG, GAS 1 PG11 GAS 3/ PG9 GAS /8 PG GAS 1/2 GAS 3/8 GAS 1/

3 > NUTS AND CAPS UNION Series IP IP A Thread mm PG21 PG PG9 PG11 Ø fixing hole 1 Cable sleeves ( ) Glow wire 0 C Cable sleeves ( ) Glow wire 90 C Couplers (with nut and seal) Heavy duty Blanking plug / / / mm 38.mm.mm.mm 33.mm 33.mm PG29 PG3 M 2X1. M 2X1. M 0x1. M 0x1. PG THREAD PG, PG1 PG21 PG / HF 0/ / HF 0/ / / / / / / / / /00 PG3, / / /20 PG2, /20 PG /20 Mx /00 M1x /00 METRIC THREAD M20x1. M2x1. Mx1. M0x / /2 80. / / / / / /20 M0x /20 M3x /20 ( ) SCABOX Series type. ( ) CUBIK Series type. 2 2

4 > CABLES TIES FOR INDOOR WIRING TIES Series > CABLES TIES FOR INDOOR WIRING TIES Series mm Grip capacity minmax Ø mm Tensile strength Kg 2, x 0,, 0/ x ,1 0/ x 1 8,1 0/ , x 1 0 8,1 0/ , x ,1 0/ , x 2 3,2 0/ , x ,2 0/ , x ,2 0/ , x ,2 0/ ,8 x 2 22, 0/ ,8 x , 0/ ,8 x , 0/ ,8 x 290 3, 9 22, 0/ ,8 x 30 3, 3 22, 0/ ,8 x 30 3, 1 22, 0/ ,8 x 0 3,,8 0/ ,8 x ,8 0/ ,8 x 3 8 0,8 0/ x , 0/ Good resistance to external agents: oil, grease, oil derivatives, alcohol, saline mist and chlorates. Do not withstand UV rays. mm Grip capacity minmax Ø mm Tensile strength Kg x 1 ( ) 2 2 0/ /1 x 1 ( ) 28 0/ /1 9 x 0 ( ) / /90 9 x 0 ( ) 2 8 0/ /90 9 x / /920 9 x / /930 ( ) RILSAN. Good resistance to external agents: oil, grease, oil derivatives and saline mist. LOADING DIAGRAM Load (kg) Load at breakingpoint Load yielding point SCAME CABLE TIES LOADELONGATION CURVE Breaking Withstands UV rays. Rounded edges to avoid cutting into cable insulation. ADHESIVE SUPPORT VIBRATION RESISTANT SUPPORT Elongation yielding point Elongation breakingpoint Elongation (%) DESCRIPTION OF LOADING DIAGRAM zones with different characteristics are clearly distinguished: 1) Elastic elongation (area of use). The cable tie is subjected to traction forces and lengthens, elastically. When the forces are taken away, the tie returns to its initial state, without any alteration of its physical characteristics. 2) Stretching of the molecular links. The tie is subjected to such a load that some of the intermolecular links are broken. The elastic properties are altered. 3) Permanent deformity. All the intermolecular links are broken. ) Breakingpoint. Length at which the tie breaks

5 > FASTENING ACCESSORIES FOR CABLE TIES TIES Series > SPRUNG CEILING HOOKS FIXO Series Selfadhesive cable tie base Screwin cable tie base antivibration Max. cable tie width:.8 mm. Max cable tie width Fixing Screw 28,x28,mm.8mm 0/ /0,x2mm.8mm M 0/ /3 Thread With open hook and nut M 0/00 8. With screw, washer and nut M 0/00 8./1 With washer and 2 nuts M 0/00 8./2 To install, fold down the tabs and push them into a mm hole in the ceiling. Once through, the tabs open up and are anchored in the ceiling. Made of metal. Dimens. Max cable Board tie width Depth thickness > FIXING PLUGS FIXO Series Wall anchor base 8mm 9mm 0mm 0/ /1 Panel clipon base,mm max.8mm 3mm max > PLIERS FOR CLAMPING AND TRIMMING CABLE TIES 0/ /2 TIES Series With screws With screws mm ø 0/2000 ø 1, ,0 x ø 0/2000 ø 8.,0 x ø 0/2000 ø 3, 8., x ø 0/2000 ø 8., x ø 8 0/2000 ø, 8.8,0 x 0 8. ø 0/2000 ø 8 8.,0 x Suitable for all type of screws (for wood, metal, concrete etc.). Made of thermoplastic material. Stainless steel screws. Without screws For screws size mm mm Suitable for all cable tie types 1/ / Made of red stoveenamelled steel. SPRUNG HOOK FIXING PLUG

6 > CABLE SHEATHS CABLO Series > SPIRAL CABLE BINDING CABLO Series inside Ø mm inside Ø mm Outside Ø 2 200/ / / / / / / / / / / / / / / / / / / / / / Made of selfextinguishing, soft and flexible insulated thermoplastic material. 0. 1mm thick. 2 2/ / / / / / /0 8.1 Made of selfextinguishing, soft and flexible, insulated thermoplastic material

7 Cable clips > FLAT CLIPS FASTY Series > INSULATED PINS FASTY Series For cables with width 3, 0/ /P /P3G 0/ /P /PG 0/ /P /PG 8 0/ /P /P8G 11 0/ /P /P11G 0/ /P /PG Pins made of hardened and nickelplated steel. Clips made of thermoplastic material. Preinserted pins. Ø 1, x 1 Packet with 0 pieces 0/ > ROUND CLIPS FASTY Series For cables Pin Ø 3 1,8 x 0/ / /3G Ø 2 x 21 0/ / /G Ø 2 x 21 0/ / /G Ø 2 x 21 0/ / /G Ø 8 2 x 21 0/ / /8G Ø 2 x 2 0/ / /G Ø 2 x 2 0/ /G Ø 1 2 x 2 0/ /1G Ø 1 2 x 3 0/ /1G Ø x 0/ /G Ø 22 x 0/ /22G Ø 2 2, x 0 0/ /2G Ø 28 2, x 0 0/ /28G Ø 2, x 0 0/ /G Pins made of hardened and nickelplated steel. Clips made of thermoplastic material. Preinserted pins

8 Din metallic rails > G TYPE RAILDIN Series > TYPE Ω RAILDIN Series Weight Kg/m Weight Kg/m xx1, Plain DIN rail 0, 20m 8.2 Slotted DIN rail (x,3 2) 0, 20m x,x1 Plain DIN rail 0,1 0m 8.20 Slotted DIN rail (x,3 2) 0, 0m 8.21 > TYPE Ω RAILDIN Series > SUPPORT BRACKET RAILDIN Series 1 M Weight Kg/m 0 3x,x1 3xx1, Plain DIN rail 0,3 0m Slotted DIN rail (x,3 2) 0,31 0m Plain DIN rail 0,8 20m Slotted DIN rail (x,3 2) 0,1 20m With M hole 0x8x1, DIN metallic rails Steel rail or mounting modular electrical equipment Steel, cold lamination Electrolytic zinc coating, followed by passivation and yellow colouring Thickness of zinc coating: 8 micron Length of the rail: 2m Non drilled rail with drilling points provided Drilled rail with slots 28 28

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH General information These connectors are designed and produced in conformity with the low-voltage directive (/3/EWG) respectively

More information

2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids.

2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids. DOMINO Series. CONSUMER UNITS AND REFERENCE STANDARDS DIMENSIONS EN 60670- Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part : general requirements.

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available

More information

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2... Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed

More information

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008 LV HRC fuse links Overview LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in switchboards of power supply companies. They therefore protect

More information

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2.. Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for

More information

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS CONCRETE / SOLID STONE USAGE 1. AREAS OF APPLICATION Heavy load-carrying attachments in solid stone, concrete, porous concrete and light concrete Suitable for attachment points close to the edge, since

More information

The OCTANORM system components set a new standard in shop design.

The OCTANORM system components set a new standard in shop design. O C TA N O R M S H O P S Y S T E M S. A B R I E F I N T R O D U C T I O N. The OCTANORM system components set a new standard in shop design. The wide range of aluminum profiles, the well designed accessories

More information

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity VX Enclosure System Technical documentation PE conductor connection, current carrying capacity Enclosure system VX Contents Contents. General remarks. Introduction. Notes on the design of the earthing

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure .13 Ex-Floodlights of the series / (Zone 2, 22) The powerful LED floodlights FMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all general lighting applications in

More information

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I I nllk / I x W x W x W x W x W Technical data Cooper Crouse-Hinds - all rights reserved nllk / nllk nllk / nllk nllk / Marking to //EC II G Ex na II T / II D td A IP T C EC Conformity Statement PTB ATEX

More information

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B Force Load Washers for Forces of 7,5... 1 200 kn Type 9001A... 9071A 9081B, 9091B 1-component force sensor for measuring dynamic and quasistatic forces in z direction. F z Calibrated measuring range 100

More information

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S EX- CONTROL UNITS AND CONTROL STATIONS EX- INSTALLATION SWITCH.. EX- CONTROL STATIONS INDIVIDUAL EX- CONTROL STATIONS.. 0 EX- CONTROL AND

More information

Temperature measurement

Temperature measurement Temperature measurement 19 2 Example of connections of particular elements Temperature display units BGK85 (page 31) Option Computer, control, itp. Temperature measurement TFC TFL (page 23) (page 23) Temperature

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series Amphenol Amphenol-Tuchel Electronics GmbH Circular Connectors C 09 A/B/D Series The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence

More information

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS For exhaust air 91% free area Handles large airflows Cleanable Can be used with commissioning box ALS Standard colour

More information

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES DISTRIBUTION BOARDS FLUSH-MOUNTING DISTRIBUTION BOARDS GWTEST SOFTWARE (see page 322) Complementary system items Ordinary installation - protected flush mounting DISTRIBUTION / JUNCTION Protection devices...

More information

Mounting kits for insulation of power transistors

Mounting kits for insulation of power transistors ounting kits for insulation of power transistors tel. 0..6.6.6 www.elitaliaweb.it fax 0.6.6.0.09 info@elitaliaweb.it ST STS ST 0 STS 0 for transistor TO TO TO 0 TO 0 version with mica wafer S with silicone

More information

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments .13 Ex-Floodlights of the series / / (Zone 2, 21, 22) The powerful LED floodlights FMV/nFMV LED The new series of energy-saving FMV floodlights in LED technology are ideal for all ge neral lighting applications

More information

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS Circular ceiling diffuser for supply air QUICK FACTS Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Non-perforated diffuser face

More information

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L Single cone ceiling diffusers for supply air Quick facts Spread pattern can be shielded Used with commissioning box ALS Cleanable Adjustable slot Perforated diffuser face = CDD Imperforated diffuser face

More information

CDS. high density spring connection

CDS. high density spring connection CDS high density spring connection DENSTY STANDARD 1A CDS DENSTY A A spring connection CDS Series The originality of multipole connectors represents one of the core values of LE, a leading company in this

More information

Universal limit switches

Universal limit switches SWITCHES.CROUZET.COM 1 LIMIT SWITCHES 0/016 Universal limit switches 8384 standard 8384 with positive break operation Conformity to standards IEC / EN 60947--1, including Annex K for version with positive

More information

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3.

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3. Overview..... 0 NOVASTAR Cabinets NOVASTAR Cabinets...... 1 Wall mounted cases........ 2 Accessories for cabinets and wall mounted cases 3 Climate control 4 Desk-top cases 5 Subracks/ 19" chassis... 6

More information

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems Krantz Components Twist outlet DD-N... for ceiling installation Air distribution systems DS E 0. Twist outlet Preliminary remarks and construction design Preliminary remarks Twist outlets for ceiling installation

More information

Imformation of C091D series

Imformation of C091D series Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent

More information

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16 Linear diffusers 1 / 1 KSV Slot diffusers Ordering code Number of slots Diffuser Length (mm) KSV - 1... - 19 Description KSV is an air terminal element primarily designated for air supply. It is suitable

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Cabinets G  integrated in upright Handle strip in side panel Easy solution for shortened doors Overview... 0 Cabinets... 1 Cabinets Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 Subracks/ 19" chassis... 6 02002002 Front panels,

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact 853 LED beacon is particularly versatile. With an

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

Thermal-Magnetic Circuit Breaker 2210-T2...

Thermal-Magnetic Circuit Breaker 2210-T2... Thermal-Magnetic Circuit Breaker 0-T... Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Featuring

More information

MR medium rating busbar

MR medium rating busbar technical information General features MR is fully compliant with S EN 0-, specifically, the rated current of the Zucchini busbar trunking systems is always rated at the average ambient temperature of

More information

BOLT SIZE Rec.Torque Ft/Lbs. Max Torque Ft/Lbs

BOLT SIZE Rec.Torque Ft/Lbs. Max Torque Ft/Lbs BOLT SIZE Rec.Torque Ft/Lbs Max Torque Ft/Lbs "-0 5 "- "- "- 5 "- "-0 () 7 (9) (5) 5 (0) 9 () 5 () 50 () 70 (95) 00 () 5 (70) 5 (70) 5 () Material Add Suffix to P/N P09 THRU P PIPE CLAMPS FOR RIGID STEEL

More information

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Explosion-protected recessed ceiling LED-light and fluorescent light fittings .7 Explosion-protected recessed ceiling LED-light and fluorescent light fittings LED 600, RLF LED 100 and self-contained emergency luminaire RLF LED 600 N, RLF LED 100 N RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX

More information

a a a a. S-2 Turbine Rev

a a a a. S-2 Turbine Rev 30-4037-1a 30-4037-0a 30-4038-1a 30-4038-0a S-2 Turbine 6-8-6 Rev. 01-24-01 6-8-6 Turbine Steam Engine Engine Parts 1.) Stanchion ( black ) FB-1200024 0.25 2.) Handrail ( nickel ) FB-12040 2.00 ( 20.0x207.0mm

More information

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Cam Roller Guides The Drive and Control Company Linear Motion

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of

More information

STEEL. General Information

STEEL. General Information General Information General Information TYPICAL STRESS-STRAIN CURVE Below is a typical stress-strain curve. Each material has its own unique stress-strain curve. Tensile Properties Tensile properties indicate

More information

General characteristics

General characteristics General characteristics This range of insulators and partition bushings provides for connecting and supporting low- and medium-voltage electrical equipment. - Their purpose is to provide electrical and

More information

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN Linear Diffusers / 8 HELLA Linear slot diffuser Ordering codes HELLA - Linear diffuser HELLA - Number of slots... Diffuser length L (mm) ) Increment mm... Deflector colour Damper Diffuser construction

More information

3D Drawing - CARIF 260 BSA

3D Drawing - CARIF 260 BSA D Drawing - CARIF 0 BSA DRAWING CODE DRAWING NAME NUMBER ASS000 Basement ASS00 Vice Base ASS00 Vice A ASS00B Vice B ASS00 Frame A ASS00B Frame B ASS000 Frame Cylinder A ASS000B Frame Cylinder B ASS000

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Air distribution systems. Radial outlet RA-N2...

Air distribution systems. Radial outlet RA-N2... Air distribution systems Radial outlet RA-N... DS E 0.01 Radial outlet RA-N Preliminary remark KRANTZ KOMPONENTEN radial outlets RA-N have fixed radial vanes and are available with circular or square face.

More information

SGF. The metric thread forming connection

SGF. The metric thread forming connection SGF The metric thread forming connection Schriever SGF Our challenge: An economical solution Alication: Direct connections in cylindrical bores and casted bores. Schriever SGF -screws are metric thread-forming,

More information

9: COTTER PINS 9: COTTER PINS COTTER PINS COTTER PINS /6" COTTER PINS 9-000 9-00 9-00 9-003 9-00 9-006 /6 X / /6 X 3/ /6 X /6 X - /6 X -/ /6 X 0 0 0 0 0 0 /6" COTTER PINS 9-08 9-0 /6 X /6 X 0 0 " COTTER

More information

Load Washers. Force kn until kn. Type 9101A A

Load Washers. Force kn until kn. Type 9101A A Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated

More information

G-FIRE FLANGE ADAPTERS

G-FIRE FLANGE ADAPTERS G-FIRE FLANGE ADAPTERS 21 G-FIRE FLANGE ADAPTERS Pictorial Table of Contents MATERIAL SPECIFICATIONS Issue 03, 04, 07 Cert No. 570, 669, 673 For detailed Listing and Approval information see pages 101-10

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

8D Series Common Section

8D Series Common Section MIL-DTL-38999 qualified crimp contacts - 1.27µm gold plated #22D type Part number Ø M39029/58 360 M39029/56 348 Conductor section AWG Conductor section mm² External Ø over insulator Min Max Min Max Min

More information

Hudevad P100. Technical datasheet

Hudevad P100. Technical datasheet Technical datasheet Key benefits Available in three depths Highly flexible in use Integrated top grille Harmonious and finished look Kundenedfal Low, streamlined design Ideal in front of glazing to prevent

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

Single point load cells

Single point load cells SP4M Single point load cells Special features Maximum capacities: kg 200 kg Aluminum High ratio of minimum verification Offcenter load compensation Shielded connection cable Explosion protection and other

More information

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials) Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme Amphenol Amphenol-Tuchel Electronics GmbH Series C 146 Heavy Duty Connectors Core Programme The Company General information These connectors are designed and produced in conformity with the voltage directive

More information

INDEX OF ILLUSTRATIONS

INDEX OF ILLUSTRATIONS INDEX OF ILLUSTRATIONS FIG 3.1.1 FIG 3.1.2 FIG 3.1.3 FIG 3.2.1 FIG 3.2.2 FIG 3.2.3 FIG 3.2.4 FIG 3.3.1 FIG 3.4.1 FIG 3.4.1.1 ENVELOPE TYPES ENVELOPE NOMENCLATURE OVERVIEW VELCRO RIP & Q-VENT BASKET NOMENCLATURE

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - L I G H T F I T T I N G S nllk 0... 1 - W All-plastic design for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 conform to the requirements of the ATEX-Directive

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings I NDEX PV LINE PX LINE PU LINE PA LINE & TUBINGS PN LINE Brass Push-in fittings Stainless Steel Push-in fittings Brass Standard fittings and Flexible Hoses Couplings and Multiple Connectors Function fittings

More information

LED Strips Downlight. Silicone_C. Hi-Flux 1.8W/ft 4000 K lm/ft IP65. 1 Linea Light. inter-lux.com/linealight

LED Strips Downlight. Silicone_C. Hi-Flux 1.8W/ft 4000 K lm/ft IP65. 1 Linea Light. inter-lux.com/linealight LED Strips 2018 Downlight InFlex Ribbon Dropper Rubber Silicone C. 3 7 13 17 Silicone_C Hi-Flux 1.8W/ft 4000 K - 1110 lm/ft IP65 1 InFlex InFlex High quality strips with selected, tested LEDs for all kinds

More information

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages

Single Module EN4165 ARINC BACC 65 EN4165. The New Standard Connector for Aircraft equipment and cabin systems. Advantages Single Module EN4165 ARINC 809 - BACC 65 EN4165 The New Standard Connector for Aircraft equipment and cabin systems. Advantages Light weight composite, modularity, color coded, push pull coupling are the

More information

Our products. Page 3-4. Chemical anchor (approval ETA/08/0231) Hammer-in capsule 5-7. Chemical mortar (approval ETA-04/0071, and -0073)

Our products. Page 3-4. Chemical anchor (approval ETA/08/0231) Hammer-in capsule 5-7. Chemical mortar (approval ETA-04/0071, and -0073) CATALOGUE Befestigungssysteme Date 02.09 Our products Chemical anchor (approval ETA/0/023) Haer-in capsule Chemical mortar (approval ETA-04/00, -002 and -003) Self leveling Construction adhesive Wedge

More information

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar Outdoor Distribution Cabinets 14.0 Chapter-Content Page 14.0 Surface Mounted Boxes 2 14.1 Flush Mounted Boxes 9 14.2 Distribution Pillar 10 23 14 http://www.krone-gmbh.at - Page 1 14.0 Surface Mounted

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Size A DIN EN

Size A DIN EN Size A DIN EN 70-0 Actuators 0 series DIN EN 70-0 +, + ow and high housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Contacts Thread Cable outlet Ordering-No. Female

More information

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

CIRCO. Sound-attenuating transfer unit QUICK FACTS

CIRCO. Sound-attenuating transfer unit QUICK FACTS Sound-attenuating transfer unit QUICK FACTS Supplied in pairs For the transfer of air through a wall Fits in a circular cut opening Simple to install Mounting frame integrated into the transfer diffuser

More information

QUAKE BRAKE TM MODEL QBC-12 SEISMIC SWAY BRACING KIT FEATURING

QUAKE BRAKE TM MODEL QBC-12 SEISMIC SWAY BRACING KIT FEATURING QUAKE BRAKE TM MODEL QBC-12 SEISMIC SWAY BRACING KIT FEATURING The QUAKE BRAKE TM Seismic Dampening Device. The QUAKE BRAKE TM was Certified NEBS Level 3 Zone Compliant after being tested in accordance

More information

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1 Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS No. E14/A1 The complete range of our products is presented in the specific catalogues: HOSE REELS CATALOGUE No. E14/A2 HOSE REELS CATALOGUE

More information

7 Revised AM001 Rev. 01/17

7 Revised AM001 Rev. 01/17 Spare Parts Price Book The Spare Parts Price Book will be used for procuring replacement parts under WMATA s micro purchasing method. While the Spare Parts Price Book is a mandatory submission for your

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output

More information

Thermal Properties Flammability: Self extinguishing UL94V-0 Maintains dimensional stability under heat:.65 C i.e..150 F as per DIN standard #53458.

Thermal Properties Flammability: Self extinguishing UL94V-0 Maintains dimensional stability under heat:.65 C i.e..150 F as per DIN standard #53458. Electro-Duct Wiring Duct Design features for speed, easy installation and assembly. Mounting slots Standard at no extra charge on all sizes of duct. Two sizes of oblong mounting holes alternating on their

More information

FRB. Exposed passive chilled beam for suspended installation

FRB. Exposed passive chilled beam for suspended installation Exposed passive chilled beam for suspended installation QUICK FACTS FRB is a passive chilled beam for comfort cooling especially designed for visible/suspended installation in the room. High cooling capacity,

More information

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic pplication Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital FOXBORO/Eckardt positioner Type SRD 992 facililates trouble free expansion to allow for

More information

Main Catalogue. Edition 23, chapter minirack: Phase-out product!

Main Catalogue. Edition 23, chapter minirack: Phase-out product! Edition 23, chapter minirack: Phase-out product! Overview... 0 Cabinets... 1 G Cabinets G Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases...

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

Instructions for Parts Books

Instructions for Parts Books Instructions for Parts Books The heading at the top of the page will be the same for the picture of the parts at it is for the page with the part numbers. Definition of column headings on part number pages:

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Blue Comet REV

Blue Comet REV -028-1 Blue Comet -6-2 REV.01101 Boiler Parts 1.) Shell ( blue & gray ) FB-1100055 *10.00 ( boiler )( # 8 ) 2.) Cab ( blue & dark blue ) FB-1100056 *0.00 ( # 8 ).) Handrail ( right )( nickel ) FB-111001

More information

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0 Tools and Supplies Required (not included): Phillips screwdriver 3/8" wrench Drill with 5/32" bit "U" type mounting bracket (i.e., part number

More information

2D - STRIP ANCHOR LIFTING SYSTEM

2D - STRIP ANCHOR LIFTING SYSTEM 2D - STRIP ANCHOR LIFTING SYSTEM WWW.TERWA.COM Terwa reserves the right to make changes to the documentation at any time Page 1 OVERVIEW LIFTING CLUTCHES AND TRANSPORT ANCHOR SA-B SA-ST SA-TTU UNIVERSAL

More information

Tisa Enterprises. The Clamping Professionals

Tisa Enterprises. The Clamping Professionals Flat Strap Clamp Material: Medium carbon steel, Hardened and Tempered : T1-FSC IS: - 4 D x L A B K S T1-FSC- x 0. T1-FSC- x 0. T1-FSC- x 0. T1-FSC-1 x 1 0. T1-FSC-1 x 1 M 1.00 T1-FSC-1 x 0 M 1. T1-FSC-0

More information

Alco PA AA Diesel Set

Alco PA AA Diesel Set 30-15-1 30--1 Alco PA AA Diesel Set GL0901 PA A Unit ( lead ) Diesel Engine 1.) Shell ( blue, yellow, silver ) FC-000 *5.00 ( A unit )( Delaware & Hudson )( # 17 ) Shell ( orange, black, silver ) FC-001

More information

The FLUX F 430 with mechanical seal

The FLUX F 430 with mechanical seal The FLUX F 0 with mechanical seal Flexible coupling between motor and pump The pump must be used with many varying liquids, consequently the smallest residual left within the pump is unacceptable. You

More information

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR CST/Berger 2001 SAL 20/24/28/32 PAGE 1 REV. C 071803 Automatic Level Maintenance Manual User Calibration and Testing... 3 Circular

More information

NORMACLAMP Hose Clamps

NORMACLAMP Hose Clamps NORMACLAMP NORMACLAMP NORMACLAMP TORRO Worm Drive Hose Clips to DIN 3017 Short description of technical features NORMACLAMP TORRO hose clips are specially suitable for applications under high mechanical

More information

M-3: Statics & M-10 Elasticity

M-3: Statics & M-10 Elasticity Group member names This sheet is the lab document your TA will use to score your lab. It is to be turned in at the end of lab. To receive full credit you must use complete sentences and explain your reasoning

More information

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great

More information