HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy

Size: px
Start display at page:

Download "HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy"

Transcription

1 HVM 6 Page /4 Elektrohydraulic Servovalves Typ HVM 6 Symbol A B P T L Special features: high reliability easy service robust construction high dynamic response relatively insensitive to contamination variable metering orifices only Qmax = 5l/min at Dp =7bar pmax = 5 bar Technical Data General description: Type : electrical input stage, torque motor, sliding spool system Pilot : none main spool : directly controlled 4-way sliding spool Style of mounting : subplate / Cetop Mounting position : unrestricted Weight :,kg. Hydraulic Data (definition according to DIN 4). pressure pn = [bar]. operating pressure pb min = [bar] pb max = 5 [bar].. return line pressure pr max = [bar] static.. no separate leakage line necessary. max. pressure (static test pressure) pmax = 45 [bar].4 flow at Dp = 7 bar QN = //5 [l/min].5 quiescent flow, max. at pn Q < 5% QN.6 hysteresis H < 4,5% i N (without Dither) % i N (with Dither).7 threshold sensitivity E <,4% i N (without Dither),% i N (with Dither).8 threshold span S < % i N (without Dither) < % i N (with Dither).9 linearity deviation < % i N. flow symmetry -QN zu +QN < % i N. pressure gain (see diagram) VN >, Pb / % i N. overlap, standard h = -...+% i N. operating temperature range dm = [K].. temperature drift % i N / 5K.4 viscosity range of fluid gmin =... mm /s approximate value normal: ISO VG...ISO VG 46.5 filtration of fluid < class 4-5 to NAS 68 or class 5/4/ to ISO 446 status /.6 fluid standard = HLP-hydraulic oils as per DIN 554 Teil (Special equipments possible)

2 HVM 6 Page /4. Diagrams HVM 6 Flow rate-signal function Q (%) 75 Q=f(i) bei Dp=constant in (%) Pressure gain Pb (%) V p = tan a = D p D I 5 A B in (%) Frequency Response Coils: x65w Power Supply.: ±V Pv: bar ±% I ±% I Amplitude / db Phase ( ) ±% I ±% I status / Hz

3 status 9/ HVM 6 Page /4.Electrical Data. Electrical Data without Electronic connector (M8x) Standard-coils parallel at and ; NC coil type inductance / coil technical Data per coil, coils ope Standard version coils parallel +V, V flow from P to B Special equipment Coils serially +V, -V flow from P to B Special equipment Coils to > to flow from P to A 6 mh ± ma 65W,65 W ± ma W, W ± ma W, W ma 65W,6 W.. Electrical Data with Electronic Power supply: 4V DC (8V... 8V) Current: 5mA max. Input signal: -V...,... +V Input : kohm Signal direction: from Pin D to Pin E Internal coil : ma... ma... ma Test signal output: Volt... V... Volt Valve oil flow: %... %... % Flow direction: +V = P > A - B > T,V = Valve closed -V = P > B - A > T.. Bloc diagram Servovalve with integ electronics A +4V B V C Spare driver D Signal+..+/-V E Signal- Sum-and-difference amplifiers contr. F Test output..+/-v G PE Ohm Protective groundings A P B T Reminds: To avoid potential drifting problems, connect Pin E with low (< ohm) to Pin B. The electrical-hydraulic working direction can be changed to reversed connection on Pin D and Pin E Cable recommendation: twisted pair cable upto cable length 5 mtr.: Type LiYCY xx,5 mm or LiYCY4xX,5mm, if you will use the test signal out. up to cable length mtr.: Type LiYCY xx,75 mm or LiYCY 4xx,75 mm, if you will use the test signal out. connector 7 pol. DIN 456 E F A B G D C View on the valve Pins visible

4 HVM 6 Page 4/4 Order Information HVM XX - E Model 6 Rated flow QN at Dp =7 bar l/min l/min l/min Seal material Perbunan Viton Butyl 4 Vulkollan 5 Ethylen-Propylen Resistance / coil [R],5 W (x65 W parallel) 65 W (coil) Overlap Zero overlap Positiv overlap Negativ overlap Amount of overlap positiv or negative..9 Design letter assigned by manufacturer Elektronic E Voltage input ±V E Current input 4...mA P > A E Current input 4...mA P > B 5.Accessories: Description Order No. Connector pol. KE Connector 9 pol. KE Connector 7pol. KE CA 6 COM 4S 7S 855 Sub plate NG 6 HZ scavenger plate NG 6 HZ Box-Amplifier BOE XXX-5--5-A status / Important remarks: Valve mounting surface must be flat within,mm and smoothness not to exceed 6µm. Easy hydraulic Zero adjustment by means of Allen key S8 DIN 9. Max. permissible drain line pressure bar.valves with modified characteristics available. Modifications, which serve technical progress, remain reserving.

5

6

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) 4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) Type 4WRL10...25 Sizes (N) 10, 16, 25 Unit series 3 Maximum working pressure P,, 350

More information

29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V *

29 188/ way Proportional Flow Control Valve Model 2 FRE 6./.,Series 2X. Ordering Code: Proportional Flow Control Valve 2 FRE 6 2X K4 V * -way roportional low Control Valve Model RE./.,Series X Size... SI ( bar).... GM ( L/min) R 9 88/.98 R 9 88/.98 Replaces:.9 With pressure compensator for the control of an oil flow independent of pressure

More information

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Direct Operated Type Solenoid Operated Proportional Directional Control Valve Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

K 080/12 F 10 K 3-2X/.. Features

K 080/12 F 10 K 3-2X/.. Features RE 2 1/11.02 Replaces: 0.2 Fine throttle Type F Nominal sizes and Series 2X and 3X Maximum operating pressure 2 bar Maximum flow 0 L/min K 00/12 F K 3-2X/.. K 0/ F P 3-3X/.. Overview of contents Contents

More information

High Pressure fi lters

High Pressure fi lters High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

Differential indicators

Differential indicators Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min Low & Medium Pressure fi lters LMP 90090 series according to DIN 0 Maximum pressure up to 0 bar Flow rate up to 000 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

ELECTROHYDROSTATIC PUMP UNIT

ELECTROHYDROSTATIC PUMP UNIT EECTROHYDROSTATIC PUMP UNIT MODUAR EECTROHYDROSTATIC PUMP UNIT FOR INDUSTRIA APPICATIONS Rev. E, February 8 WHAT MOVES YOUR WORD INTRODUCTION Whenever the highest levels of motion control performance and

More information

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

2017 HYDAC International GmbH. All rights reserved, also regarding any disposal, VT-info exploitation, 51A new reproduction, series 4WE10

2017 HYDAC International GmbH. All rights reserved, also regarding any disposal, VT-info exploitation, 51A new reproduction, series 4WE10 2017 HYDAC International GmbH. All rights reserved, also regarding 2018-04 any disposal, VT-info exploitation, 51A new reproduction, series 4WE10 SPECIFICATIONS pmax. = 350 bar Qmax. = 160 l/min direct

More information

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure transmitters for industrial applications MBS 32 and MBS 33 Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

Safety valve with unit approval type MV..X.., SV..X..

Safety valve with unit approval type MV..X.., SV..X.. Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for

More information

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog with release valve with silencer with non-return valve, With filter vacuum switch: electronic x PNP and x analog Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / + C Working

More information

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters High Pressure fi lters FMP series Maximum pressure up to 0 bar Flow rate up to 7 l/min High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar Flow rate up to 0 l/min 79 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces

More information

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN Directional spool valve type SWPN Nom. size 6 or 10 conformg DIN 24 340 Max. pressure Max. flow = 350 bar = 150 lpm 1. General The valves illustrated here are directly actuated directional spool valves

More information

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting. Manually Operated Directional s DM- / / DMG- / / / / hread Connection / Mounting Specifications hreaded Connections Numbers DM--C - DM--D - DM--D - DM--B - DM- -C - DM- -D - DM- -D - ( ) (.) (.) (.) (.)

More information

387 Low & Medium Pressure filters

387 Low & Medium Pressure filters Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

Drive electronics pq12

Drive electronics pq12 Drive electronics pq12 Amplifier module with constant current controller for proportional valves Control of one solenoid Easy mounting directly on bearing rails acc. to EN 50022 Standard voltage and current

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original) ISO 154071/ Distributors E Integrated electrical connection (ISO 15407/) B M1 connector (Automotive) A Single electrical connection (ISO 15407/1) A Pneumatic connection (ISO 15407/1) ISO 0 ISO Interface

More information

331 Low & Medium Pressure filters

331 Low & Medium Pressure filters Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the

More information

4/3, 4/2 and 3/2 directional valve with wet-pin AC or DC solenoid

4/3, 4/2 and 3/2 directional valve with wet-pin AC or DC solenoid 01/0 /3, / nd 3/ directionl vlve with wet-pin AC or DC solenoid Type WE...L7X.11 Size (NG) Up to 315 br Up to 0 L/min Contents Function nd configurtions Specifictions Symbols 03 Technicl dt 03 Electric

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

D a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories

D a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories D a t a s h e e t T o r q u e s t a n d a r d S e r i e s D m - T N ( 1 N m 0 0 0 0 N m ) Benefits/Application Class VN (better class 0,05 acc. DIN 51309) For highest precision requirements Easy adaption

More information

Load Washers. Force kn until kn. Type 9101A A

Load Washers. Force kn until kn. Type 9101A A Force Load Washers 0... 20 kn until 0... 700 kn Type 9101A... 9107A Force sensor for measuring quasistatic and dynamic forces in industrial monitoring tasks. F z The force sensors are delivered uncalibrated

More information

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO. DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link

More information

I-FORCE Ironless linear motors

I-FORCE Ironless linear motors I-FORCE Ironless linear motors Parker Trilogy s I-Force ironless linear motors offer high forces and rapid accelerations in a compact package. With forces ranging from 5.5 lbf (24.5 N) - 197.5 lbf (878.6

More information

FLOW SENSOR FOR LIQUID MEDIA Serie 210

FLOW SENSOR FOR LIQUID MEDIA Serie 210 FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available

More information

G 1/8 - G 3/8 G 1/2 - G 1 1/2. Poppet valves for compressed air 3/2

G 1/8 - G 3/8 G 1/2 - G 1 1/2. Poppet valves for compressed air 3/2 Poppet valves for compressed air Produced in a complete range of sizes from G 1/8 up to G 1 1/ these valves are particularly suitable for applications where high flow rates and high cycle rates are required.

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

2/2-3/2 POPPET VALVES FOR VACUUM (1/8"-6/4") Series AG

2/2-3/2 POPPET VALVES FOR VACUUM (1/8-6/4) Series AG 2/2/2 POPPET VLVES FOR VCUUM (1/"/") Series G G / 1/2 complete range: / / G/ G/ 1/2 Original Univer poppet system appreciated for decades Servoassisted version complete range of solenoid valves and valves

More information

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division

More information

Flow rates to 475 l/min

Flow rates to 475 l/min FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass

More information

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2 Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with

More information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q

More information

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en T20WN Torque transducers Data Sheet Special features - Nominal (rated) torques 0.1 N m, 0.2 N m, 0. N m, 1 N m, 2 N m, N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m - Accuracy class: 0.2 - Contactless transmission

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27 Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for

More information

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure

More information

IXTA180N10T IXTP180N10T

IXTA180N10T IXTP180N10T Trench TM Power MOSFET IXTA8NT IXTP8NT V DSS I D25 R DS(on) = V = 8A 6.4m N-Channel Enhancement Mode Avalanche Rated TO-263 (IXTA) G S Symbol Test Conditions Maximum Ratings V DSS = 25 C to 75 C V V DGR

More information

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation

More information

K04 TYPE -40 C +85 C 20000H

K04 TYPE -40 C +85 C 20000H K04 TYPE -40 C +85 C 20000H Extended life. Surge-proof capacitor in aluminium can with insulation sleeve. To be mounted with ring clips or with threaded stud. Designed for high resistances to voltage spikes.

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm BD ISO 15071/ Valves CHARACTERISTICS Ambient temperature Fluid Commutation system Max pressure Connections Nominal bore (mm) Nominal flow rate (Nl/min) Valve body Seals Spool Electropilot/Coil Voltage

More information

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

IXFN56N90P. = 900V = 56A 145m 300ns. Polar TM HiPerFET TM Power MOSFET V DSS I D25. R DS(on) t rr

IXFN56N90P. = 900V = 56A 145m 300ns. Polar TM HiPerFET TM Power MOSFET V DSS I D25. R DS(on) t rr Polar TM HiPerFET TM Power MOSFET N-Channel Enhancement Mode Avalanche Rated Fast Intrinsic Rectifier S I D25 R DS(on) t rr = 9V = 56A 145m ns Symbol Test Conditions Maximum Ratings S = 25 C to 1 C 9 V

More information

all stainless steel transducer multimedia compatibility

all stainless steel transducer multimedia compatibility all stainless steel transducer multimedia compatibility High-Performance Silicon technology LARGE INVENTORY Fast Shipment! 0-0.07 to 0-690 bar 100 mv, 0 to 5 V, and 4 to 20 ma Outputs U 1, 2 & 5 psi Low

More information

Over Current Protection Circuits Voltage controlled DC-AC Inverters Maximum operating temperature of 175 C

Over Current Protection Circuits Voltage controlled DC-AC Inverters Maximum operating temperature of 175 C Description United Silicon Carbide, Inc offers the xj series of high-performance SiC normally-on JFET transistors. This series exhibits ultra-low on resistance (R DS(ON) ) and gate charge (Q G ) allowing

More information

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level

More information

AIR BREATHER FILTERS. Temperature from -25 to +100 C

AIR BREATHER FILTERS. Temperature from -25 to +100 C IR BRETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of

More information

Cartridge Valves Technical Information

Cartridge Valves Technical Information Quick reference CONTENTS CPF20... 8.2 CP600-5... 8. CP602-5... 8.4 20662 handle kit... 8.5 MP06... 8.6 MP2... 8.6 BC06... 8.9 BC0... 8.0 BC... 8. CP0-... 8. CP904-... 8.4 SC0... 8.5 SC... 8.6 DIN connectors...

More information

Over Current Protection Circuits Voltage controlled DC-AC Inverters Maximum operating temperature of 175 C

Over Current Protection Circuits Voltage controlled DC-AC Inverters Maximum operating temperature of 175 C Description xj SiC Series 8mW - 12V SiC Normally-On JFET UJN128Z Die Form United Silicon Carbide, Inc offers the xj series of high-performance SiC normally-on JFET transistors. This series exhibits ultra-low

More information

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ. LOREM IPSUM JE ZULT MAAR HZ m Head m/s m/s m/s m/s m/s Ø m Ø Ø Ø Ø l/s Flow kw Shaft power P Ø m/h Ø 9 Ø Ø kw 9 Total input power P Ø DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, xv AP-, AKP- and AEP-

More information

14:1400 (0206) KRAL Volumeter - OMG

14:1400 (0206) KRAL Volumeter - OMG 14:1400 (0206) KRAL Volumeter - OMG OMG - Universal OMG The flowmeter for a wide range of applications Operating Conditions and Materials Flow Range: 0.1 to 7,500 l/min Max. Pressure: 250 bar Temperature

More information

SKA DDL IRON CORE LINEAR MOTORS. Direct Drive Technology

SKA DDL IRON CORE LINEAR MOTORS. Direct Drive Technology Direct Drive Technology SKA DDL IRON CORE LINEAR MOTORS Copyright 2007 Motor Power Company. All rights reserved. Contents are subjected to change without any notice. Edition 05/12 SKA DDL LINEAR MOTOR

More information

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I. 8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel

More information

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters Spin-on fi lters MPS series Maximum pressure up to bar - Flow rate up to 65 l/min 6 Spin-on fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

LSIC1MO120E V N-channel, Enhancement-mode SiC MOSFET

LSIC1MO120E V N-channel, Enhancement-mode SiC MOSFET LSIC1MO12E8, 12 V, 8 mohm, TO-247-3L LSIC1MO12E8 12 V N-channel, Enhancement-mode SiC MOSFET RoHS Pb Product Summary Characteristics Value Unit V DS 12 V Typical R DS(ON) 8 mω I D ( T C 1 C) 25 A Circuit

More information

UNISONIC TECHNOLOGIES CO., LTD

UNISONIC TECHNOLOGIES CO., LTD UNISONIC TECHNOLOGIES CO., LTD COMPLEMENTARY OUTPUT HALL EFFECT LATCH DESCRIPTION The UTC H654 is integrated Hall sensors with complementary output drivers designed for electronic commutation of brushless

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS Type PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

IXTY18P10T IXTA18P10T IXTP18P10T

IXTY18P10T IXTA18P10T IXTP18P10T TrenchP TM Power MOSFET P-Channel Enhancement Mode Avalanche Rated IXTY18P1T IXTA18P1T IXTP18P1T V DSS = - 1V I D = - 18A R DS(on) 12m TO52 (IXTY) G S Symbol Test Conditions Maximum Ratings V DSS = C to

More information

ZF Series Force Transducers

ZF Series Force Transducers Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series

More information

FSUSB31 Low-Power 1-Port Hi-Speed USB 2.0 (480Mbps) Switch

FSUSB31 Low-Power 1-Port Hi-Speed USB 2.0 (480Mbps) Switch Low-Power 1-Port Hi-Speed USB 2.0 (480Mbps) Switch Features Low On capacitance, 3.7pF (typical) Low On resistance, 6.5Ω (typical) Low power consumption (1µA maximum) 10µA maximum I CCT over and expanded

More information

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach

More information

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length

More information

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

AIR BREATHER FILTERS. Temperature from -25 C to +100 C IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of

More information

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Hydraulic Pressure NAH Applications. Features. New generation available - refer to NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for

More information

Flow rates to 590 l/min

Flow rates to 590 l/min LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball

More information

PS12038 Intellimod Module Application Specific IPM 25 Amperes/1200 Volts

PS12038 Intellimod Module Application Specific IPM 25 Amperes/1200 Volts D M SQ PINS G L A F H K E J D VV QQ PP C 24 2 9 6 3 9 7 8 7 4 2 8 RR (4 PLACES) B N P Q R S Y EE XX V T LL DD GG TT SS X 2 3 4 GG T C FF LABEL T C 6 DD GG GG U P 2 N 3 NC 4 U V 6 W TERMINAL CODE 9 GND

More information

IXTH80N65X2 V DSS. X2-Class Power MOSFET = 650V I D25. = 80A 38m. R DS(on) N-Channel Enhancement Mode Avalanche Rated TO-247 G D S

IXTH80N65X2 V DSS. X2-Class Power MOSFET = 650V I D25. = 80A 38m. R DS(on) N-Channel Enhancement Mode Avalanche Rated TO-247 G D S X2-Class Power MOSFET V DSS = 6V I D25 = A 38m R DS(on) N-Channel Enhancement Mode Avalanche Rated TO-247 Symbol Test Conditions Maximum Ratings V DSS = 25 C to 1 C 6 V V DGR = 25 C to 1 C, R GS = 1M 6

More information

OEM Flow sensor for liquid media type 200

OEM Flow sensor for liquid media type 200 OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán

More information

35RP2 35RP2 HM 2 HM 3 35RP2. Type. Series Variation. Rack and pinion type Bore (mm) Rotating angle Angle adjustment.

35RP2 35RP2 HM 2 HM 3 35RP2. Type. Series Variation. Rack and pinion type Bore (mm) Rotating angle Angle adjustment. 2 3 Type Series Variation Rack and pinion type (mm) 3243 1 ngle adjustment Rated torque 32Nm 4Nm 22Nm (at 3. MPa) 343Nm 4Nm Maximum allowable pressure 3. MPa Proof test pressure MPa Minimum operating pressure.

More information

ATS177. General Description. Features. Applications. Ordering Information SINGLE OUTPUT HALL EFFECT LATCH ATS177 - P L - X - X

ATS177. General Description. Features. Applications. Ordering Information SINGLE OUTPUT HALL EFFECT LATCH ATS177 - P L - X - X Features General Description 3.5V to 20V DC operation voltage Temperature compensation Wide operating voltage range Open-Collector pre-driver 25mA maximum sinking output current Reverse polarity protection

More information

N-Channel Enhancement-Mode Vertical DMOS FET

N-Channel Enhancement-Mode Vertical DMOS FET N-Channel Enhancement-Mode Vertical DMOS FET Features Free from secondary breakdown Low power drive requirement Ease of paralleling Low C ISS and fast switching speeds Excellent thermal stability Integral

More information