Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

Size: px
Start display at page:

Download "Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters"

Transcription

1 Spin-on fi lters MPS series Maximum pressure up to bar - Flow rate up to 65 l/min 6 Spin-on fi lters

2 FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for the return filter the pressure drop have to be in the range bar. The pressure drop calculation is performed by adding together the value of the housing with the value of the filter element. The pressure drop in the housing is proportional to the fluid density (kg/dm ); all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop is proportional to its viscosity (mm /s), the corrective factor Y is related to an oil viscosity different than 0 mm /s. Sizing data for single cartridge, head at top pc = housing pressure drop [bar] pe = element pressure drop [bar] Y = Multiplication factor Y (see correspondent table), depending on the filter element size, on the filter element lenght and on the filter media Q = flow rate (l/min) V reference viscosity = 0 mm /s (cst) V = operating viscosity in mm /s (cst) pe = Y : 000 x Q x (V/V) p Tot. = pc + pe Calculation examples with HLP Mineral oil Variation in viscosity Application data: Top tank return filter with in-line connections Pressure Pmax = 0 bar Flow rate Q = 0 l/min Viscosity V = 6 mm /s (cst) Oil viscosity = 0.86 kg/dm Required filtration efficiency = 5 μm with absolute filtration With bypass valve and / inlet connection From the working pressure and the flow rate we understand it should be possible using the following top tank return filter series: MPT, MPH and FRI. Let s proceed with MPT series. The size 0 doesn t achieve the required flow rate, therefore we have to consider the size 00. The final version of size 00 (0, 0, 0, 0 and ) will be then defined in function of the mounting characteristics. pc = 0.0 bar ( see graphic below, considering size 00 with the max available lenght * to get the lowest pressure drop) pe = (.0 : 000) x 0 x (6/0) = 0.7 bar p Tot. = = 0. bar The selection is correct because the total pressure drop value is inside the admissible range for top tank return filters. It is of course possible trying to find a different solution, according to the mounting position or to other commercial need, repeating the previous steps while using a different series or lenght. Δp bar MPT 0 - Length * G / Flow rate l/min housings p pressure drop. The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Return filters element Type MF 00 MF 00 MFX 00 MF 00 MFX 00 MF 80 MFX 80 MF 90 MFX 90 MF 00 MFX 00 MF 750 MFX 750 CU 05 CU 00 CU 00 CU 50 CU 60 CU 850 MR 00 MR 50 MR 60 MR A Absolute filtration Nominal filtration H Series N Series A06 A0 A6 A5 P0 P5 M5 M60 M Introduction 0

3 Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s Suction filters element Type SF 50 Nominal filtration N Series P0 P5 65 Low & Medium pressure filters element Type CU 0 A FILTER SIZING Absolute filtration Nominal filtration N-W Series N Series A06 A0 A6 A5 P0 P5 M Return / Suction filters element Type RSX 6 A0 5.. Absolute filtration A6..87 A5.85. CU 0 DN RSX CU CU CU MR Introduction

4 FILTER SIZING Corrective factor Corrective factor Y, to be used for the filter element pressure drop calculation. The values depend to the filter size and lenght and to the filter media. Reference viscosity 0 mm /s High pressure filters element Type HP 0 A Absolute filtration N - R Series A06 A0 A A Nominal filtration N Series M Stainless steel high pressure filters element Type HP 0 A Absolute filtration N Series A06 A0 A A HP HP HP HP HP HP HP 5 HP element Type HP 0 A Absolute filtration H - U Series A06 A0 A A HP HP element Type A0 Absolute filtration N Series A06 A0 A6 A5 Nominal filtration N Series M5 HP HF HP Introduction

5 Selection Software FILTER SIZING Step Select FILTERS Step Choose fi lter group (Return, Pressure, etc.) Step Choose fi lter type (MPF, MPT, etc.) in function of the max working pressure and the max fl ow rate Step Push PROCEED Step 5 Insert all application data to calculate the fi lter size following the sequence: - working pressure - working fl ow rate - working pressure drop - working temperature - fl uid material and fl uid type - fi ltration media - connection type Step 6 Push CALCULATE to have result; in case of any mistake, the system will advice which parameter is out of range to allow to modify/adjust the selection Step 7 Download PDF Datasheet Report.aspx pushing the button Drawing Introduction

6 Spin-on filters 60

7 Spin-on fi lters MPS series Maximum pressure up to bar - Flow rate up to 65 l/min 6 Spin-on fi lters

8 MPS GENERAL INFORMATION Technical data Spin-on filters Maximum pressure up to bar - Flow rate up to 65 l/min housing materials - Head: Aluminium - Bypass valve: Nylon - Steel - Element: Zinc-Plated Steel. Painted Steel Pressure - Working pressure:. MPa ( bar) Bypass valve - Return filter opening pressure: 75 kpa (.75 bar) - Suction filter opening pressure: 0 kpa (0. bar) p element type - p: 5 bar - Fluid flow through the filter element from OUT to IN. Seals Standard NBR - series A Temperature From -0 C to +0 C Note MPS filters are provided for vertical mounting Weights [kg] and volumes [dm ] MPS 050 MPS 05 MPS 070 MPS 07 MPS 00 MPS 0 MPS 50 MPS 5 MPS 00 MPS 50 MPS 00-0 MPS 50-5 Weights [kg] Volumes [dm ] Spin-on filters 6

9 GENERAL INFORMATION MPS Pressure drop The curves are plotted using mineral oil with density of 0.86 kg/dm in compliance with ISO 968. p varies proportionally with density. Bypass valve pressure drop MPS 050/070 In-Line/Return - Setting.75 bar MPS In-Line/Return - Setting.75 bar Δp bar Δp bar Flow rate l/min Flow rate l/min 0 MPS 050/070 In-Line/Suction - Setting 0 kpa 0 MPS In-Line/Suction - Setting 0 kpa Δp kpa 80 0 Δp kpa Flow rate l/min Flow rate l/min 6 Spin-on filters

10 MPS GENERAL INFORMATION Hydraulic symbols Style S MPS Style B MPS Style S MPS Style B MPS Style S MPS Style B MPS Style S MPS Style B MPS Style S MPS 0-5 Style B MPS 0-5 Spin-on filters 6

11 GENERAL INFORMATION MPS Heads CG / CW - UNF CS G/ CG / CW / - 6 UN CS G / Cartridge CS CG - CW CG - CW CW This series of cartridge removes water from oil while filtering the oil at the same time. Water absorbent polymers up to 800 times their own weight provide this major feature. Water holding capacities: CW 050= 0 ml Ordering code: CW050P0AP0 CW 50= 788 ml Ordering code: CW50P0AP0 Element CS CS CG / CW CG / CW Thread connections Connection G/ G / - UNF / - 6 UN Viscosity H O p.p.m. Flow rate Temperature Water holding capacities CW good poor 0/6 mm/s (cst) > 6 mm/s (cst) 600/800 p.p.m. > 800 p.p.m. CW050 7/5 l/min CW050 > 0 l/min CW50 0/0 l/min CW50 > 50 l/min 0/60 C < 0 C 65 Spin-on filters

12 MPS MPS050 - MPS070 MPS05 - MPS07 Designation & Ordering code Series and size MPS050 MPS05 MPS070 MPS07 With connections for clogging indicators With connections for differential indicators COMPLETE FILTER Configuration example : MPS050 R G A0 A P0 Bypass valve R Return:.75 bar S Suction: 0 kpa U Without bypass P Without bypass G G/ G / NPT G SAE - /6 - UN G SAE 8 - / - 6 UNF G5 G G6 NPT MPS MPS Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seal A NBR Execution P0 MP Filtri standard CARTRIDGE Cartridge series and size CS050 CS070 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 Resin impregnated paper 0 µm P5 Resin impregnated paper 5 µm Configuration example: Seals A NBR CS050 A0 A P0 Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Clogging indicators on RETURN line page page BVA Axial pressure gauge 95 BEA Electrical pressure indicator 9 BVR Radial pressure gauge 95 BEM Electrical pressure indicator 9 BVP Visual pressure indicator with automatic reset 96 BLA Electrical / visual pressure indicator 9-95 BVQ Visual pressure indicator with manual reset 96 Clogging indicators on SUCTION line page page VVB Axial pressure gauge 9 VEB Electrical vacuum indicator 9 VVS Radial pressure gauge 9 VLB Electrical/visual vacuum indicator 9 Differential indicators page page DEA Electrical differential indicator 97 DTA Electronic differential indicator 00 DEM Electrical differential indicator DVA Visual differential indicator 00 DLA Electrical / visual differential indicator DVM Visual differential indicator 00 DLE Electrical / visual differential indicator 99 Spin-on filters 66

13 MPS050 - MPS070 MPS05 - MPS07 MPS Dimensions MPS050 SF500 - MPS070 size G G-G-G G5 G6 T G/8 /8 NPT G/8 /8 NPT H [mm] 9 56 R M6 / UNC M6 / UNC Recommended Recommended clearance clearance space space for for maintenance maintenance MPS05 SF500 - MPS07 size H [mm] 9 56 G G-G-G G5 G6 R M6 / UNC M6 / UNC Recommended clearance space for maintenance 67 Spin-on filters

14 MPS MPS00 - MPS50 MPS0 - MPS5 Designation & Ordering code Series and size MPS00 MPS0 MPS50 MPS5 With connections for clogging indicators With connections for differential indicators COMPLETE FILTER Configuration example : MPS00 R G A0 A P0 Bypass valve R Return:.75 bar S Suction: 0 kpa U Without bypass P Without bypass G G / G / NPT G SAE 0-5/8 - UN MPS MPS 0-5 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seal A NBR Execution P0 MP Filtri standard CARTRIDGE Cartridge series and size CS00 CS50 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 Resin impregnated paper 0 µm P5 Resin impregnated paper 5 µm Configuration example: Seals A NBR CS00 A0 A P0 Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Clogging indicators on RETURN line page page BVA Axial pressure gauge 95 BEA Electrical pressure indicator 9 BVR Radial pressure gauge 95 BEM Electrical pressure indicator 9 BVP Visual pressure indicator with automatic reset 96 BLA Electrical / visual pressure indicator 9-95 BVQ Visual pressure indicator with manual reset 96 Clogging indicators on SUCTION line page page VVB Axial pressure gauge 9 VEB Electrical vacuum indicator 9 VVS Radial pressure gauge 9 VLB Electrical/visual vacuum indicator 9 Differential indicators page page DEA Electrical differential indicator 97 DTA Electronic differential indicator 00 DEM Electrical differential indicator DVA Visual differential indicator 00 DLA Electrical / visual differential indicator DVM Visual differential indicator 00 DLE Electrical / visual differential indicator 99 Spin-on filters 68

15 MPS00 - MPS50 MPS0 - MPS5 MPS Dimensions MPS00 SF500 - MPS50 size G G-G T G/8 /8 NPT H [mm] 6 95 R M8 5/6 UNC Recommended clearance space Recommended for maintenance clearance space for maintenance MPS0 SF500 - MPS5 size 0 5 H [mm] 6 95 G G-G R M8 5/6 UNC Recommended clearance space for maintenance 69 Spin-on filters

16 MPS MPS00 - MPS50 Designation & Ordering code Series and size MPS00 MPS50 COMPLETE FILTER Configuration example : MPS00 R G A0 A P0 Bypass valve R Return:.75 bar S Suction: 0 kpa U Without bypass G G / G / NPT G SAE - 7/8 - UN Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seal A NBR Execution P0 MP Filtri standard CARTRIDGE Cartridge series and size CS00 CS50 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 Resin impregnated paper 0 µm P5 Resin impregnated paper 5 µm Configuration example: Seals A NBR CS00 A0 A P0 Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Clogging indicators on RETURN line page page BVA Axial pressure gauge 95 BEA Electrical pressure indicator 9 BVR Radial pressure gauge 95 BEM Electrical pressure indicator 9 BVP Visual pressure indicator with automatic reset 96 BLA Electrical / visual pressure indicator 9-95 BVQ Visual pressure indicator with manual reset 96 Clogging indicators on SUCTION line page page VVB Axial pressure gauge 9 VEB Electrical vacuum indicator 9 VVS Radial pressure gauge 9 VLB Electrical/visual vacuum indicator 9 Spin-on filters 70

17 MPS00 - MPS50 MPS Dimensions MPS00 SF500 - MPS50 size G G-G T G/8 /8 NPT H [mm] 6 R M0 7/6 UNC Recommended clearance space for maintenance Recommended clearance space for maintenance 7 Spin-on filters

18 MPS MPS00 - MPS50 MPS0 - MPS5 Designation & Ordering code Series and size MPS00 MPS0 MPS50 MPS5 With connections for clogging indicators With connections for differential indicators COMPLETE FILTER Configuration example : MPS00 R F A0 A P0 Bypass valve R Return:.75 bar S Suction: 0 kpa U Without bypass P Without bypass G G / G / NPT G SAE - 7/8 - UN F / SAE 000 psi/m F / SAE 000 psi/unc MPS MPS 0-5 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 P5 Resin impregnated paper 0 µm Resin impregnated paper 5 µm Seal A NBR Execution P0 MP Filtri standard CARTRIDGE Cartridge series and size CS00 CS50 Filtration rating (filter media) A0 Inorganic microfiber µm M5 Wire mesh 5 µm A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm A0 Inorganic microfiber 0 µm M90 Wire mesh 90 µm A5 Inorganic microfiber 5 µm P0 Resin impregnated paper 0 µm P5 Resin impregnated paper 5 µm Configuration example: Seals A NBR CS00 A0 A P0 Execution P0 MP Filtri standard Pxx Customized ACCESSORIES Clogging indicators on RETURN line page page BVA Axial pressure gauge 95 BEA Electrical pressure indicator 9 BVR Radial pressure gauge 95 BEM Electrical pressure indicator 9 BVP Visual pressure indicator with automatic reset 96 BLA Electrical / visual pressure indicator 9-95 BVQ Visual pressure indicator with manual reset 96 Clogging indicators on SUCTION line page page VVB Axial pressure gauge 9 VEB Electrical vacuum indicator 9 VVS Radial pressure gauge 9 VLB Electrical/visual vacuum indicator 9 Differential indicators page page DEA Electrical differential indicator 97 DTA Electronic differential indicator 00 DEM Electrical differential indicator DVA Visual differential indicator 00 DLA Electrical / visual differential indicator DVM Visual differential indicator 00 DLE Electrical / visual differential indicator 99 Spin-on filters 7

19 MPS00 - MPS50 MPS0 - MPS5 MPS Dimensions MPS00 SF500 - MPS50 size G G-G F F T G/8 /8 NPT G/8 /8 NPT H [mm] 66 5 R M0 7/6 UNC M0 7/6 UNC Recommended clearance space for maintenance 7 Spin-on filters

20 MPS Dimensions MPS00 - MPS50 MPS0 - MPS5 MPS0 SF500 - MPS5 size 0 5 H [mm] 66 5 G G-G F F R M0 7/6 UNC M0 7/6 UNC Recommended clearance space for maintenance Spin-on filters 7

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar Flow rate up to 0 l/min 79 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

High Pressure fi lters

High Pressure fi lters High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct

More information

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min Low & Medium Pressure fi lters LMP 90090 series according to DIN 0 Maximum pressure up to 0 bar Flow rate up to 000 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be

More information

331 Low & Medium Pressure filters

331 Low & Medium Pressure filters Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the

More information

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters High Pressure fi lters FMP series Maximum pressure up to 0 bar Flow rate up to 7 l/min High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

387 Low & Medium Pressure filters

387 Low & Medium Pressure filters Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters Suction fi lters & MPA MPM series Flow rate up to 87 l/min 7 Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,

More information

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation

More information

Flow rates to 475 l/min

Flow rates to 475 l/min FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

STAINLESS STEEL FILTER

STAINLESS STEEL FILTER STINLSS STL FILTR Style FZ Stainless Steel Pressure filter Technical data Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:

More information

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I. 6 FMP SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Cast iron (chemical heat

More information

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I. 5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n SERIES INLINE FILTERS LMP 0 Maximum pressure 60 bar Maximum flow to 0 0 l / mi n SERIES LMP 0 Working pre s s u re 60 bar Style S Style B B B D.I. D.I. A A Technical data Filter housing ( M a t e r i a

More information

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure

More information

SERIES. Maximum pressure 8 bar

SERIES. Maximum pressure 8 bar SERIES Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n OLD MPF 00 NEW MPF 00 8 75 80 5-6 5,5 5,5 Nr. holes Ø 8,5 55 55 Nr. slots Ø 8,5 Up to: G NPT SAE 6 Up to: G / SAE 0 DIFFERENCE BETWEEN...

More information

Polígono Indutrial O Rebullón s/n Mos - España -

Polígono Indutrial O Rebullón s/n Mos - España - FP 5 Polígono Indutrial O Rebullón s/n. 646 - Mos - spaña - rodavigo@rodavigo.com SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Polígono Indutrial O Rebullón s/n. 646

More information

Flow rates to 590 l/min

Flow rates to 590 l/min LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball

More information

FMP :41 Pagina 5 (1,1) FMP

FMP :41 Pagina 5 (1,1) FMP FMP 6-07-006 9:4 Pagina 5 (,) FMP 6 FMP 6-07-006 9:4 Pagina 5 (,) SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 FMP 6-07-006 9:4 Pagina 7 (,) Technical data Filter

More information

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I. 8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel

More information

MPF SERIES RETURN FILTER

MPF SERIES RETURN FILTER MPF SERIES The series of filters MPF has specifically been designed for use on mobile applications, agricultural machinery and power units. The MPF filter range is suitable for flow rates up to 750 l/min.

More information

MPT Multifunction Multiport

MPT Multifunction Multiport MP Multifunction Multiport Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n echnical data housing (Materials) ead: luminium Cover: Nylon Bowl: Nylon Pressure Working pressure: 8 bar emperature

More information

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax:

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax: FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com

More information

AIR BREATHER FILTERS. Temperature from -25 to +100 C

AIR BREATHER FILTERS. Temperature from -25 to +100 C IR BRETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of

More information

Polígono Indutrial O Rebullón s/n Mos - España -

Polígono Indutrial O Rebullón s/n Mos - España - FB 8 Polígono Indutrial O Rebullón s/n. 646 - Mos - España - rodavigo@rodavigo.com SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Polígono Indutrial

More information

FMM 050 uk :26 Pagina 5 (1,1) FMM 050

FMM 050 uk :26 Pagina 5 (1,1) FMM 050 uk 6-07-006 9:6 Pagina 5 (,) 30 uk 6-07-006 9:6 Pagina 5 (3,) SRIS Working pressure 80 bar Style S Style Style T Style D 3 uk 6-07-006 9:6 Pagina 7 (,) Technical data Filter body ( M a t e r i a l s )

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 96, when Bruno Pasotto decided to attempt to cater for the requests of a market still

More information

Maximum pressure 80 bar

Maximum pressure 80 bar Maximum pressure 80 bar F l o w r a t e s t o 0 0 l / m i n LMP 0 Maximum pressure 80 bar F l o w r a t e s t o 6 0 l / m i n Technical data LMP 0 Filter housing (Materials) Head: luminium Housing: ataphoresis

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

mandata_us :43 Pagina 83 (1,1) FHB 82

mandata_us :43 Pagina 83 (1,1) FHB 82 8 FHB SERIES FHB Working pressure 4600 psi Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body ( M a t e r i a l s ) Head: Cast iron (chemical heat tre a t

More information

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials) Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

Cartridge Valves Technical Information. Quick reference

Cartridge Valves Technical Information. Quick reference Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...

More information

MRH. Return Filters RETURN FILTER

MRH. Return Filters RETURN FILTER MRH Return ilters RETUR ILTER Return ilters MRH MRH MPa (0 bar) Port sizes: / / low rates:.00 l/min TECHICAL ATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa ( bar) ursting pressure: 6 MPa

More information

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

AIR BREATHER FILTERS. Temperature from -25 C to +100 C IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of

More information

Nylon oil filler and air breather filler caps

Nylon oil filler and air breather filler caps Series TP 0 Dimensions 6 Bayonet G / TP0 (Materials) - Cover/ringnut: Nylon - Filter element: Impregnated paper Polyurethane - Pressurisation valve: Nylon Galvanised Steel - Seal: Reservoir holes - Flange:

More information

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min Return Filters RFM RFM kpa (3 bar) Ports: 3/ 2 1/2 Flow rates: 0 l/min ECHNICAL DAA Max. working pressure: kpa (3 bar) Max. test pressure: 00 kpa ( bar) Bursting pressure: 1 MPa (10 bar) Fatigue test:

More information

Differential indicators

Differential indicators Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively

More information

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Direct Operated Type Solenoid Operated Proportional Directional Control Valve Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg) Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be

More information

Metal air breather filter

Metal air breather filter Series S Metal air breather filter 4 H 5 6 7 H H S (Materials) Screw: Galvanised Steel Washer: Teflon Cover: Steel 4 Filter element: Impregnated paper 5 Ring: Galvanised Steel 6 Seal: R 7 Connection: nodised

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

close to performances of the turbine gas meters designed for custody transfer measurements.

close to performances of the turbine gas meters designed for custody transfer measurements. QUANTOMETER DESIGN AND FUNCTION CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flow measurements. Our great experience

More information

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS 1. What is the head loss ( in units of bars) across a 30mm wide open gate valve when oil ( SG=0.9) flow through at a

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

Cartridge Valves Technical Information

Cartridge Valves Technical Information Quick reference CONTENTS CPF20... 8.2 CP600-5... 8. CP602-5... 8.4 20662 handle kit... 8.5 MP06... 8.6 MP2... 8.6 BC06... 8.9 BC0... 8.0 BC... 8. CP0-... 8. CP904-... 8.4 SC0... 8.5 SC... 8.6 DIN connectors...

More information

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1 1. A pipe 100 mm bore diameter carries oil of density 900 kg/m3 at a rate of 4 kg/s. The pipe reduces

More information

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems 06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated

More information

Modular Style Air Combination. Assembled by simply tightening the screws

Modular Style Air Combination. Assembled by simply tightening the screws Modular Style Air Combination Series AC Assembled by simply tightening the screws High strength die cast bracket Drain cock for one push drain exhaust Oil needle for easy oil volume adjustments The improved

More information

Odor Removal Filter Series AMF

Odor Removal Filter Series AMF Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,

More information

K 080/12 F 10 K 3-2X/.. Features

K 080/12 F 10 K 3-2X/.. Features RE 2 1/11.02 Replaces: 0.2 Fine throttle Type F Nominal sizes and Series 2X and 3X Maximum operating pressure 2 bar Maximum flow 0 L/min K 00/12 F K 3-2X/.. K 0/ F P 3-3X/.. Overview of contents Contents

More information

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC / Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.

More information

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure

More information

ED 701 General Industry Pressure Transmitter

ED 701 General Industry Pressure Transmitter ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy

HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy HVM 6 Page /4 Elektrohydraulic Servovalves Typ HVM 6 Symbol A B P T L Special features: high reliability easy service robust construction high dynamic response relatively insensitive to contamination variable

More information

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) 4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed

More information

Zeta Plus LP Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges

Zeta Plus LP Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges Lenntech info@lenntech.com Tel. +3-52-6-9 www.lenntech.com Fax. +3-52-66-289 Zeta Plus LP Zeta Plus LP filter media is a depth filter composed of inorganic filter aid cationic resin and cellulose and is

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8426 Second edition 2008-02-01 Hydraulic fluid power Positive displacement pumps and motors Determination of derived capacity Transmissions hydrauliques Pompes et moteurs volumétriques

More information

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves 2/2-way direct-operated type EV210A MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.

More information

Cooling Water Flow Regulator

Cooling Water Flow Regulator Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data

More information

PR CYCLONE SECONDARY SHUTOFF

PR CYCLONE SECONDARY SHUTOFF EN PR CYCLONE SECONDARY SHUTOFF ORIGINAL INSTRUCTIONS CYCLONE SECONDARY SHUTOFF PR530 CYCLONE SECONDARY SHUTOFF PR330 CYCLONE SECONDARY SHUTOFF PR200-250 CYCLONE SECONDARY SHUTOFF PR150 TECHNICAL DATA

More information

Pressure Transmitter ED 701

Pressure Transmitter ED 701 Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation

More information

External gear pump Type G3, Series 3X

External gear pump Type G3, Series 3X NS to 5 External gear pump Type G3, Series 3X Up to 2 bar Up to 5.2 cm 3 RE 039/07.00 Replaces: 03.00 Plain bearings for high loads Mono-block bearing New principle of hydrostatic gap compensation Drive

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:

More information

Zeta Plus HT Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges

Zeta Plus HT Series. Lenntech. Applications. Features and Benefi ts. Lenticular Depth Filter Cartridges Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Zeta Plus Series Zeta Plus Series is a charge-modifi ed depth fi lter constructed with high-tensile strength media

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents

More information

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8 Discharge: 8 Spherical solids handling: 3 SELF-PRIMING CENTRIFUGAL TRASH PUMP Series: SH-U Suction: " Discharge: " Spherical solids handling: 3" SIZE BEARING - PUMP END " x " NPT, lbs., female flange. Open single ball, radial load. LIQUID TEMPERATURE

More information

CKA Series. 3-way jaw thin chuck double acting/single acting. Operational stroke length: 5, 6, 7, 9, 20, 25, 30, 38mm.

CKA Series. 3-way jaw thin chuck double acting/single acting. Operational stroke length: 5, 6, 7, 9, 20, 25, 30, 38mm. G G B A S F J L L H LB N/ S/F Specifications Descriptions Size Cylinder bore size Operating method Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke

More information

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

MN-ISO-2000FN-E.   ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL MN-ISO-2000FN-E www.insize.com ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL V0 Place the probe on the zero plate and wait until beep. Lift the probe for minimal 5 cm off the zero plate and wait

More information

Volume flow rate sensors

Volume flow rate sensors Volume flow rate sensors Kalibrierdienst K - 00-0 DIN EN 00 DIN EN ISO 900 00 79 Test with confidence Messen mit System English Hydrotechnik gear flow meters type GFM Gear flow meters are used for the

More information

Safety valve with unit approval type MV..X.., SV..X..

Safety valve with unit approval type MV..X.., SV..X.. Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for

More information

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS VE 37 HYDROMEHNIS EXERISE PROLEMS 1. pump that has the characteristic curve shown in the accompanying graph is to be installed in the system shown. What will be the discharge of water in the system? Take

More information

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

DN 1/4 to 4 Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1) Specifications : Anti blow-out stem PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 4" Male, Female BSP - 10 C + 120 C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore Materials

More information

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent). Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 1 Free nut BSP, male or female - 10 C + 120 C Max Pressure : 20 Bars Specifications : Before or after water meter PTFE packing With free nut

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

PRESSURE GAUGE SELECTORS

PRESSURE GAUGE SELECTORS PRESSURE GUGE SELECORS Gauge isolator valves are designed to protect pressure gauges from pressure shocks when the pressure reading is not required; after each reading setting the selector to the closed

More information