Modular Style Air Combination. Assembled by simply tightening the screws

Size: px
Start display at page:

Download "Modular Style Air Combination. Assembled by simply tightening the screws"

Transcription

1 Modular Style Air Combination Series AC Assembled by simply tightening the screws High strength die cast bracket Drain cock for one push drain exhaust Oil needle for easy oil volume adjustments The improved needle and the easily grasped handle make for easier oil volume adjustments Pressure gauge A pressure gauge equipped with a limit indicator on which the prescribed pressure range can be viewed at a glance. (Applicable to 20 0 to 60 0) One-hand lock with colour indicator The handle can be operated more reliably because the locked state of the pressure regulation handle can be checked at a glance by whether the orange mark is visible. If the orange mark is visible, the pressure can be regulated. (0 0, 0, 0 only) Bowl can be attached and detached with one hand. (Turn proof structure at pressurized state).-

2 Air Combination Series AC Standard Combinations Constructing equipment ++ Combination Port size AC000 AC2000 M5 /8, / Air filter Regulator Lubricator Filter regulator Mist separator M AC AV AC20 /, / AU AC000 AC00 AC00-06 AC00 AC50 /, /8 /, /8, /2 / /, IR VEX AC SRP + AC00 M AC200 AC00 AC0 AC0-06 AC020 AC2020 /8, / /, /8 /, /8, /2 / M5 /8, / AMR M D ITV VBA AC2520 AC020 AC20 /, /8 /, /8 /, /8, / AC20-06 / AC20 /, AC AC M+ AC200 /8, / M2000 AC250 /, / M000 AC00 /, / M000 AC0 /, /8, / M00 AC0-06 / M M AC20 /8, / 2000 M2000 AC0 /, /8 000 M000 AC /, /8, /2 00 M00 AC-06 / M

3 Series AC How to Order Air combination Body size 0 M5 20 /8 25 / 0 /8 /2 / Combination of equipment Combination of equipment Symbol Filter Regulator Lubricator Filter Mist () () () regulator separator () (M) 00 q w e 0 w q 20 q w 0 q e w q w () Numbers in K indicate the constructing order from the left hand side (upper stream) with a view from front. Ex.) Symbol (Available only for AC00 to 0.) M+ (Available only for AC200 to 0.) +M (Available only for AC20 to.) (2) Standard bracket for a set of 2 pieces: T type bracket A set of pieces or more: L type bracket N F Accessories (Options) Symbol C D E AC 0 00 F 0 D ST 2R Ordering source area code Japan, Asia - Australia E Europe N North America Description Auto drain Auto drain Pressure gauge Thread Metric thread (M5) Rc (PT) NPT (PF) M Port size M5 X 0.8 /8 / /8 /2 / Applicable model Float style (N.C.): AC20 to AC6000 Pressure differential style: AC000, AC2000 Float style (N.O.): AC20 to AC6000 Without limit indicator: AC000 With limit indicator: AC2000 to AC6000 T V If indicating more than one symbol, place the desired symbols in numerical order then alphabetical order. Example) 2NR Note ) Only adjusting spring of regulator is different from standard specification. Note 2) Without valve mechanism. Attachments Symbol Description Mounting location Applicable of attachment model None + + K + AC2000 to AC00 K Check valve + K + AC200 to AC0 + + S + AC2000 to AC6000 S Pressure switch + S + AC2020 to AC M + S + AC200 to AC0 T type interface Residual pressure exhaust port valve Option specifications () Set at 0.02 to 0.2MPa (Regulator) C J (2) N R W Metal bowl (Filter/Lubricator) Lubricator with drain cock Nylon bowl (Filter/Lubricator) Metal bowl with level gauge (Filter/Lubricator) (Applicable to AC20 to AC6000.) Bowl guard (Applicable to AC20 0 only.) Drain guide port size / (AC20 to AC6000) Non relieving style (Regulator) Flow direction: Right to left Drain cock with barb fitting: For ø6/ø nylon (Filter) (Applicable to AC20 to AC6000) + T + + AC000 to AC T + AC020 to AC M + T + AC200 to AC V + + V + + V + M + + V + M + V AC2000 to AC00 AC200 to AC0 AC2020 to AC20 AC200 to AC0 AC20 to AC Air intermediate output port size AC20 0: / 8 AC25 0: / AC0 0: / AC 0: / 8 AC0 0: M5 X 0.8 AC20 0: / 8 AC25 0: / AC0 0: / AC 0: / 8 AC 0: / 8 AC55 0: / 2 AC60 0: / 2 Note ) If indicating more than one symbol, place the desired symbols in alphabetical order. Note 2) For piping adapter, pressure switch with piping adapter and cross interface, indicate part number, separately. Note ) Consult SMC if using pressure switch and T type interface simultaneously..-

4 Air Combination Series AC Option Specifications Combination List Accessory Option specification Description Accessory F.R.L. Combination applicable model Option specification (Auto drain) AC000 AC2000 AC2020 AC2520 AC000 AC00 AC020 AC00 AC0 AC020 AC200 AC20 to to D D C C J N R W AC00 AC200 AC20 AC250 AC6000 AC0 AC6020 AC0 AC Auto drain press. differential D Auto drain float style (N.O.) D Auto drain float style (N.C.) C Set at 0.02 to 0.2 MPa - Metal bowl -2 Lubricator with drain cock - Nylon bowl -6 Metal bowl with level gauge -8 With bowl guard -C Drain guide (Port size / ) -J Non relieving style -N Flow direction: right to left -R One-touch drain cock w/ barb fitting -W Attachments Piping adapter Symbol : Combination possible : Combination impossible : Depends on the model Port size M5 / 8, /, / 8, / 2, /, Mechanism Able to connect and disconnect equipment without detaching piping. AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch with piping adapter / 8, /, / 8, / 2, / Compact switch united with piping adapter Check valve Pressure switch T type interface / 8, /, / 8 M5 / 8, /, / 8, /2 Prevents reverse flow from lubricator. Compact switch Able to diverge air. Residual pressure exhaust port valve / 8, /, / 8, /2 Able to exhaust residual pressure in the line. Cross interface M5 / 8, /, / 8, /2 Able to diverge piping in all directions..-

5 Air Combination Air Filter + Regulator + Lubricator AC000 to 6000 JIS symbol AC2000 AC000 AC00 Standard Specifications Air filter Regulator Lubricator AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 Air filter Combination equipment Regulator Lubricator Port size M5 /8 / / / / /8 / / /8 /8 /2 auge port size /6 /8 /8 /8 / / / / / Fluid Air Proof pressure.5 MPa Max. operating pressure.0 MP Set pressure range 0.05 to 0. MPa 0.05 to 0.85 MPa Flow (l/min(anr))(port size) () 0 (M5 X 0.8) 0( / ) 0( / 8 ) 2000( / 8 ) 00( / 2 ) ( / ) 00( / ) 6000() 6000() Ambient and fluid temperature Filtration 5 to 60 C (Non-freezing) 5µm Recommended lubricant Bowl material Construction/Regulator Turbin oil class (ISO V2) Polycarbonate Relieving style Weight (kg) Accessory Bowl guard (Standard equipment) Bracket B0L B20L B0L B0L B0L B50L B60L B60L B60L Note ) Supply pressure: 0. MPa, Set pressure: 0.5 MPa Attachments/Accessories (Options) Attachment Accessory Part No. Description For AC000 For AC2000 For AC20 For AC000 For AC00 For AC00-06 For AC00 For AC50 For AC Piping adapter E0-M5 E20- E0- E E- 0 E- 06 E60- E60- E Pressure switch with piping adapter IS000E- Y 2 IS000E- Y IS000E- Y IS000E- 0 Y Check valve (2) 0 AKM2000- (02) AKM000- (0) AKM000- (0) AKM00- (02) Pressure switch IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y IS000M-6Y IS000M-6Y T type interface (2) 0 (0) (0) (02) (02) (0) (0) Y-M5 Y2- (02) Y- Y- Y- Y5- Y6- (0) Y6-0 Y6-0 Residual press. exhaust port valve 0 VHS2000- VHS000- VHS000- VHS Cross interface Y-M5 Y2- Y- Y- Y- Y5-0 T type bracket B0T B20T B0T B0T B0T B50T B60T B60T B60T Interface Y0 Y20 Y0 Y0 Y Y Y60 Y60 Y60 Pressure.0MPa 2-0-R gauge 0.2MPa (2-0-R) () Auto drain N.O. AD AD AD AD AD AD AD float () N.C. AD5 AD5 AD5 AD5 AD5 AD5 AD5 Auto drain w/ press. diff. AD6 AD62 Note 2) Standard specification of air combination: Port size without ( ) Note ) Use the one for.0mpa Note ) Minimum operating pressure: N.O. 0. MPa, N.C. 0.5MPa -0, -02, -0, -0, -06, -0 after part number indicate port size. (0: / 8, 02: /, 0: / 8, 0: / 2, 06: /, 0: ) Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges..-5

6 AC000 to 6000 Flow Characteristics Condition: Supply pressure 0.MPa AC000 M5 AC00-06 Rc(PT)/ AC2000 Rc(PT)/ AC00 Rc(PT)/ AC20 Rc(PT)/ 8 AC50 Rc(PT) AC000 Rc(PT)/ 8 AC6000 Rc(PT) AC00 Rc(PT)/ 2 Precaution Be sure to read before handling. Refer to p.0-26 and 0-2 for Safety Instructions and common precautions on the products mentioned in this catalogue, and refer to p..0- and.0-2 for precautions on every series. Warning Selection qfor AC00, 0, 0 and with float style auto drain(n.o.), use 2.2kW or larger compressor. Because 2 auto drains are used and 200l/min air is needed, it might malfunction with a compressor weaker than the required ability. Caution qin case of mounting a regulator in up right direction, no pressure switch(is000m- ) attachment or T type interface can be mounted, for it touches bonnet. It is the same as a filter regulator. wthere is possibility of oil flowing back when mounting T type interface onto the supply side of lubricator and take out in the middle. It cannot be used for air non lubrication style. To use it as for air non lubrication style, it is necessary to use check valve(series AKM) to prevent reverse flow. emounting pressure switch and T type interface on the IN side of check valve makes it impossible to take out piping in the middle of check valve. rwhen mounting residual pressure release port valve directly to the IN side of a lubricator, use check valve (Series AKM) to prevent reverse flow of oil. tpressure switch and T type interface cannot be mounted to OUT side of residual pressure release port valve, as a part of the products interferes. Warning Caution Piping qwhen mounting check valve, make sure of the position of mark which indicates an entrance of air (IN side), and connect. Air Supply qif residual pressure release port valve is to be mounted, use an air filter 5µm filtration rating or less to prevent any damage on sheet part by dust, paper, etc. AC AV AU IR VEX SRP AMR M D ITV VBA.-6

7 AC000 to 6000 Pressure Characteristics Conditions: Supply pressure 0.MPa, Secondary pressure 0.2MPa, Flow 20l/min(ANR) AC000 M5 AC00-06 Rc(PT)/ AC2000 Rc(PT)/ AC00 Rc(PT)/ AC20 Rc(PT)/ 8 AC50 Rc(PT) AC000 Rc(PT)/ 8 AC6000 Rc(PT) AC00 Rc(PT)/ 2.-

8 AC000 to 6000 Dimensions AC000/2000 AC AV AU AC20/000/00/00/50/6000 Port size A B C D M N P R E F H J K L AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 Option AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 M5 / 8, / /, / 8 /, / 8 /, / 8, / 2 / /, Barb fitting With drain guide Metal bowl B B B Metal bowl with level gauge Bracket mounting size For piping adapter AC20, 000, port size /2: mm, For AC00, port size /: mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different. With auto drain Float Press. Diff. B B 05.5 IR VEX SRP AMR M D ITV VBA.-8

9 Air Combination Filter Regulator + Lubricator AC00 to 0 JIS symbol AC00 AC200 AC00 Standard Specifications Combination equipment Port size auge port size (Rc(PT)) Fluid Proof pressure Max. operating pressure Filter regulator Lubricator Filter regulator Lubricator AC00 AC200 AC00 AC0 AC M5 /8 / / /8 / /8 /2 / /6 /8 /8 / / Air.5MPa.0MPa Set pressure range Ambient and fluid temperature Recommended lubricant Bowl material Construction/Filter regulator Weight (kg) Accessory (Standard equipment) Bowl guard Bracket (2) Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Note 2) For a set of pieces or more: L type bracket Attachments/Accessories (Options) Attachment Accessory Flow (l/min(anr)) (Port size) () Filtration Description Piping adapter Pressure switch with piping adapter Check valve () Residual pressure exhaust port valve Cross interface Interface.0MPa Pressure gauge 0.2MPa N.O. Auto drain float style (5) N.C. Auto drain pressure differential style 0.05 to 0. MPa 0(M5) B0T B20T 0.05 to 0.85 MPa 0(/ ) 00(/8) 000(/2) 000(/) 5 to 60 C (Non-freezing) 5µm Turbin oil class (ISO V2) Polycarbonate Relieving style 0.8 B0T. B0T. B50T Part No. For AC00 For AC200 For AC00 For AC0 For AC0-06 E0-M5 E20-0 E0-0 E E- 06 IS000E- IS000E- 0 S000E Y AKM (02) AKM000- (0) AKM00- (02) VHS00- VHS VHS000-0 Y-M5 Y2-0 Y- 0 Y- Y5-0 0 Y0 Y20 Y0 Y Y 2-0-R (2-0-R) () AD AD AD AD5 AD5 AD5 AD6 AD62 Note ) Standard specification of air combination: Port size without ( ) Note ) Substitute.0MPa type. -0, -02, -0, -0, -06, after part number indicate port size. (-0: /8, -02: /8, -0: /8, -0: /2, -06: /) Note 5) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 6) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges..-

10 AC00 to 0 Dimensions AC00/200 AC AV AU IR AC00/0 VEX SRP AMR M D ITV VBA Port size A B C D E M N P R F H J K L AC00 AC200 AC00 AC0 AC0-06 Option AC00 AC200 AC00 AC0 AC0-06 M5 58 / 8, / 0 /, / 8 /, / 8, / 2 5 / Barb fitting With drain guide Metal bowl Metal bowl with level gauge B B B B Bracket mounting size With auto drain Float Press. Diff. B B For piping adapter AC00, port size /2: mm For AC0, port size /: mm For options (with barb fitting, with drain fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different..-0

11 Air Combination Air Filter + Regulator AC020 to 6020 AC20 AC020 AC2020 AC020 JIS Symbol Standard Specifications Air filter Regulator AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 Combination Air filter equipment Port size Attachment Accessory Regulator auge port size Fluid Proof pressure Max. operating pressure Set pressure range Flow (l/min(anr))(port size) () Ambient and fluid temperature Filtration Bowl material Construction/Regulator Weight (kg) Accessory Bowl guard (Standard equipment) Bracket (2) M5 / to 0. MPa 00 (M5 X 0.8) /8 / /8 Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Note 2) Set of or more than pieces: L type bracket Attachments/Accessories (Options) / / / /8 / /8 / /8 /2 /8 /8 / / / / / Air.5 MPa.0 MPa 0.05 to 0.85 MPa 5(/) 0(/8) 2000(/8) 00(/2) 00(/) 6000(/) 000() 8000() 5 to 60 C (Non-freezing) 5µm Polycarbonate Relieving style B0T B20T B0T B0T B0T B50T B60T B60T B60T Part No. Description For AC020 For AC2020 For AC2520 For AC020 For AC20 For AC20-06 For AC20 For AC5520 For AC6020 Piping adapter E0-M5 E20-0 E E E E- 06 E E E Pressure switch 2 with piping adapter IS000E IS000E Y IS000E- 02 IS000E Y 0 Y Y Pressure switch IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y IS000M-6Y IS000M-6Y T type interface () Y-M5 Y2-0 (02) Y- (0) 02 Y- (0) 02 Y- (02) 0 Y5- (02) 0 Y6- (0) 0 Y6- (0) Y6-0 (0) 0 Residual press. exhaust port valve VHS00-02 VHS VHS VHS Cross interface Y-M5 Y Y Y Y Y5-0 0 Interface Y0 Y20 Y0 Y0 Y Y Y60 Y60 Y60.0MPa Pressure 2-0-R gauge 0.2MPa (2-0-R) () Auto (5) N.O. AD AD AD AD AD AD AD drain float N.C. AD5 AD5 AD5 AD5 AD5 AD5 AD5 Auto drain press. differential AD6 AD62 Note ) Standard specification of air combination: Port size without ( ) Note ) Substitute.0MPa type. Note 5) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 6) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauge. -0, -02, -0, -0, -06, -0 after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: /, -0: ).-

12 AC020 to 6020 Dimensions AC020/2020 AC AV AU AC2520/020/20/20/5520/6020 Bracket mounting size Port size A B C D E M N P R F H J K L AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 Option AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 M5 / 8, / /, / 8 /, / 8 /, / 8, / 2 / /, Barb fitting With drain guide Metal bowl Metal bowl with level gauge B B B B For piping adapter AC2520, 020, port size / 2: mm For AC20, port size / : mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different. With auto drain Float Press. Diff. B B IR VEX SRP AMR M D ITV VBA.-2

13 Air Combination Air Filter + Mist Separator + Regulator AC200 to 0 JIS symbol Standard Specifications Combination equipment Port size auge port size Fluid Proof pressure Max. operating pressure Min. operating pressure Set pressure range Flow (l/min (ANR)) () Air filter Mist separtor Regulator AC0 Ambient and fluid temperature 5 to 60 C (Non-freezing) Filtration : 5µm, M: 0.µm(5% scavening particle diameter) Density of oil mist on secondary side Max..0mgf/Nm ( 0.8ppm) (2) Bowl material Polycarbonate Construction/Filter regulator Relieving style Weight (kg) Accessory Bowl guard (Standard equipment) Bracket B20L B0L B0L B0L Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Rated flow changes depending on supply pressure Note 2) With compressor discharging density of 0mgf/Nm Air filter Mist Regulator separator AC200 AC250 AC00 AC0 AC M M M M M /8 / / / /8 / /8 /8 /2 / /8 /8 /8 / / Air.5MPa.0MPa 0.05MPa 0.05 to 0.85MPa Attachments/Accessories (Options) Part No. Description For AC200 For AC250 For AC00 For AC0 For AC0-06 Attachment Accessory.- Piping adapter Pressure switch with piping adapter Pressure switch T type interface () Residual pressure exhaust port valve Cross interface T type brcket Interface Pressure gauge Auto drain float style ().0MPa 0.2MPa N.O. N.C. Auto drain pressure differential style E IS000E- AC B50L IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y Y2-0 (02) E0-0 (0) Y- E0-0 (0) Y- B20T B0T B0T B0T B50T Y20 Y0 Y0 Y Y AD AD AD AD AD5 AD5 AD5 AD5 AD62 Note ) Standard specification of air combination: Port size without ( ). Note ) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT gauges. -0, -02, -0, -0, -06, after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: / ) Y VHS Y2-0 IS000E- Y 0 VHS000- Y- 0 AC00 IS000E- Y 0 VHS000- Y- E IS000E- Y 0 06 (02) Y- VHS00-0 Y- E- 06 Y5-0 (02) Y5- Y5-0

14 AC200 to 0 Dimensions AC200 AC AV AU IR AC250/00/0 VEX SRP AMR M D ITV VBA Port size A B C D E M N P F H J K L AC200 AC250 AC00 AC0 AC0-06 Option AC200 AC250 AC00 AC0 AC0-06 8,, 8, 8, 8, Barb fitting With drain guide Metal bowl Metal bowl with level gauge B B B B Bracket mounting size With auto drain Float For piping adapter AC250, 00, port size 2: mm For AC0, port size : mm For options (with barb fitting, with drin guide, metal bowl, with level gauge), body length (B dimension) is different. Press. Diff. B B

15 Air Combination Filter Regulator + Mist Separator AC20/0/ JIS symbol AC20 Standard Specifications AC AC0 Filter regulator Mist separator Combination equipment Port size auge port size Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Filter regulator Mist separator Set pressure range Flow (l/min (ANR))(Port size) () Density of oil mist on secondary side Bowl material Construction/Filter regulator Weight (kg) Accessory (Standard equipment) Bowl guard Bracket () AC20 AC0 AC AC M M000 M00 /8 / / /8 / /8 / 2 / /8 /8 / / Air.5MPa.0MPa 0.05MPa 0.05to0.85MPa to 60 (Non-freezing) : 5µm, M: 0.µm(5% scavenging particle diameter) Max.0mgf/Nm ( 0.8ppm) (2) Polycarbonate Relieving style Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Rated flow changes depending on supply pressure. Note 2) With compressor discharging density of 0mgf/Nm Note ) L bracket for a set of pieces or more. 0.6 B20T M00-06 Attachments/Accessories (Options) Part No. Description For AC20 For AC0 For AC For AC-06 Attachment Accessory.-5 Filtration Piping adapter Pressure switch with piping adapter Residual pressure exhaust port valve Cross interface Interface Pressure.0MPa gauge 0.2MPa Auto drain float style () N.O. N.C. Auto drain pressure differential style E B0T E IS000E- 2 2 Y IS000E- Y VHS B0T E B50T E- 06 Note ) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges. -0, -02, -0, -06 after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: / ) 0 VHS000- IS000E- Y 0 06 VHS00-0 Y2-0 Y- 0 Y- Y5-0 Y20 Y0 Y Y AD AD AD AD5 AD5 AD5 AD62

16 AC20/0/ Dimensions AC20 AC AV AU IR VEX AC0/ SRP AMR M D ITV VBA Bracket mounting size Port size A B C D E M N P F H J K L AC20 AC0 AC AC-06 / 8, / /, / 8 /, / 8, / 2 / With auto drain Float Press. Diff. B B 8.5 Option AC20 AC0 AC AC-06 Barb fitting With drain guide Metal bowl Metal bowl with level gauge B B B B For piping adapter AC0, port size / 2 : mm For AC, port size / : 5mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different..-6

17 Attachments Piping Adapter M5, / 8, /, / 8, / 2, /, Easy maintenance. Makes it possible to attach and detach equipment without removing piping. E0-02 Piping adapter To order piping adapter with bracket, the parts number as shown below. (Example) With L type bracket: E 0L- With T type bracket: E 0T- One with AC installed is special product. Port size A B C Applicable model E0-M5 E20-0 E20- E20- E0- E0- E0-0 E- E- E- 0 E- 06 E- 06 E60-06 E60-0 M5 6 / 8 / 2 / 8 / 26 / 8 / 2 / / 8 / 2 / / / AC0 0, , 000, 000 AC , 2000, , M2000, D AC25 0, AC , 000, , M000, D AC 0 00, 00, 00 00, M00, D00 AC , 00-06, , M00-06, D00-06 AC00, AC50, AC6000 AC20, AC5520, AC , 00, , 6000, 6000 Note ) in part number indicates thread type. Use nothing for Rc(PT), N for NPT and F for (PF). T Type Interface: (T) M5, / 8, /, / 8, / 2 Makes it easy to diverge air out with T type interface. Y Y Caution on Assembling T type interface T type interface cannot be mounted at IN/OUT side of or upward handle of. When T type interface is used at IN side of lubricator, oil may have entered. Use check valve series AKM. Port size A B C Applicable model Y-M5 M AC000, AC020 Y2-0 / AC2000, AC2020, 200 Y2- / Y- 0 / 8 AC20, AC2520, AC250 Y- / AC000, AC020, AC00 Y- / 2 AC00, AC20, AC0 Y- / 8 Y5- / AC00-06, AC20-06 Y5-2 / 8 AC0-06 Y6- / 8 AC00, AC50, AC6000 Y / 2 AC20, AC5520, AC6020 When T type interface with bracket is required, order as example below. (Example) With L bracket: Y L- With T bracket: Y T- Refer to a table of attachment on P..- for standard port size when applying to AC. in part number indicates thread. Use nothing for Rc(PT), N for NPT and F for (PF)..-

18 Attachments Pressure Switch with Piping Adapter JIS symbol Specifications Fluid Proof pressure Max. operating pressure Set pressure range (off) Differential Ambient and fluid temperature Switch Characteristics Contact point structure Max. contact point capacity Voltage AC, DC Max. operating current How to Order IS000E 0 YL Air.0MPa 0.MPa 0. to 0.6MPa 0.08MPa 5 to 60 C (No condensation) a 2V AC/2W DC 2V, 2V, 8V, 00V AC, 2V to 2V DC: ma AC, 8V DC: ma AC, 00V DC: 20mA Q () Port size IS000E-2 0Y / 8 IS000E-2Y / IS000E-2Y / 8 IS000E-Y / IS000E-Y / 8 IS000E- 0Y / 2 IS000E-Y / IS000E-Y / 8 IS000E- 0Y / 2 IS000E- 06Y A B C D Applicable model AC2000, AC200, AC2020 AC200, AC AC20, AC2520, AC250 AC000, AC00, AC020 AC00, AC0 000, 0 AC00, AC0, AC20 AC0, AC 00, (2) / Note) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). Note2) Can NOT be mounted on "AC 0-06" and " 0-06". With retainer, O ring and bolt. Consult SMC when mounting the pressure switch on "AC 0-06" and " 0-06". For more information, refer to p AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch with piping adapter 2 N F Body size For AC2000 For AC20, AC000 For AC00-02 to 0 Thread Rc(PT) NPT (PF) Attachment Y YL YT Piping adapter port size Options X20 Length of lead wire: m X202 Setting pressure range: 0. to 0.6MPa X25 Length of lead wire: m, (0. to 0.6MPa) Without attachment With attachment With attachment and L type bracket With attachment and T type bracket / 8 / / 8 / 2 / Attachments for IS000E Pressure switch applicable model No. IS000E-20 to 20 IS000E-02 to 0 IS000E-2 to 6 Y type standard Y20E Y0E YE YL type with L type bracket Y20LE Y0LE YLE YT type with T type bracket Y20TE Y0TE YTE.-8

19 Attachments Check Valve: (K) Rc(PT) / 8, /, /8 Diverges on the secondary side of regulator. Makes it easier to mount check valve with a middle take out port which prevents reverse flow of lubricant oil from lubricator when releasing air. Check valve AKM000 JIS symbol Specifications AKM2000 AKM000 AKM00 Note) Use this check valve when diverging on the supply side of. IN/OUT port is not made for thread piping. How to Order E AKM Check valve Body size 20 / 8 0 / 8 / 2 Ordering source area code Japan, Asia - Australia E Europe N North America Effective area (mm 2 ) F 0 Thread N F Rc(PT) NPT (PF) Diverging port size 0 / 8 02 / 0 / 8 Diverging port size AKM2000 / 8, / AKM000 / 8, / AKM00 /, / 8 A B Applicable model AC2000, AC200 AC20, AC250 AC000, AC00 AC00, AC0 () Note ) Not applicable to AC Refer to the attachment list on p..- for standard diverging port size when applying to AC. C D E Caution on Assembling Pressure switch and T type interface can not be mounted on the IN side. Piping adapter E0-M5 E20-0 to0 E0-02 to0 E-02 to06 E-06 E Pressure switch with piping adapter IS000E-20 to 20 IS000E-02 to 0 IS000E-2 to 6.-

20 Attachments Pressure Switch: (S) Compact pressure switch can be mounted easily. Makes it easier to detect pressure in lines. Pressure switch Specifications Fluid Proof pressure Max. operating pressure Set pressure range (off) Differential Ambient and fluid temperature Switch Characteristics Contact point structure Max. contact point capacity Voltage AC, DC Max. operating current For more information, refer to SMC Pressure switch catalog. (Catalog No.E82) How to Order IS000M YT Air.0MPa 0.MPa 0. to 0.6MPa 0.08MPa 5 to 60 C(No condensation) a 2V AC/2W DC 2V, 2V, 8V, 00V AC, 2V to 2V DC: ma AC, 8V DC: ma AC, 00V DC: 20mA Q JIS symbol IS000M-2Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y A B C D E F Caution on Assembling Applicable model AC2000, AC2020, AC200 AC20, AC2520, AC250 AC000, AC020, AC00 AC00, AC20, AC0 AC00-06, AC20-06 AC0-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 Attachment for pressure switch can be installed at the IN/OUT side of,,, M and D. Mounting at the IN/OUT side of and upward handle of is not possible. AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch Body size For AC2000 For AC20, AC000 For AC00-02 to 0 For AC00-06 For AC00, AC6000 Attachment Y YL YT Options X20 X202 X25 Length of lead wire: m Set pressure range: 0. to 0.6MPa Length of lead wire: m,(0. to 0.6MPa) Without attachment With attachment With attachment and L type bracket With attachment and T type bracket Attachments for IS000M Pressure switch applicable model No. IS000M-2 IS000M- IS000M- IS000M-5 IS000M-6 Y type standard Y20M Y0M YM YM Y60M YL type with L type bracket Y20LM Y0LM YLM YLM Y60LM YT type with T type bracket Y20TM Y0TM YTM YTM Y60TM.-20

21 Attachments Cross Interface M5, /8, /, / 8, / 2 Make it possible to diverge piping in all directions. Note) IN/OUT port is not machined for thread piping. Cross interface Cross interface Y-M5 Y2-0, 02 Y-0, 02 Y-02, 0 Y5-0, 0 Residual Pressure Exhaust Port Valve: (V) Residual pressure exhaust port valve makes it easier to exhaust pressure. Residual pressure exhaust port valve E: -Rc(PT) F: Without thread Port size A B C D Applicable model Y-M5 M AC000, AC00, AC020 Y2-0 8 AC2000, AC200, AC2020 Y2-22 AC200, AC20 Y- 0 AC20, AC2520, AC250 8 Y AC000, AC00, AC020 AC00, AC0 Y- AC00, AC0, AC20 Y AC0, AC Y Y5-0 2 AC-06 Note ) in parts number indicates thread. Use nothing for Rc(PT), N for NPT and F for (PF). 62 Caution on Assembling AC00-06, AC0-06 AC20-06, AC0-06 When mounting directly onto the IN side of lubricator, use check valve series AKM between the interface and lubricator. Installation to AC will be available as a special product. Please consult SMC. Specifications Port size Effective area (mm 2 ) IN to OUT OUT to EXH VHS2000 VHS VHS Note) Use air filter on the IN side to protect operation. How to Order E.-2 VHS Residual pressure exhaust port valve Ordering source area code Japan, Asia - Australia E Europe N North America 0 00 F 02 Body size Thread N F Port size Rc(PT) NPT (PF) IN/OUT Port size EXH Port size A B C VHS2000 8, VHS000, () VHS00, 8, Note ) NOT applicable to AC Caution on Assembling Pressure switch and T type interface can not be mounted to OUT side of residual pressure exhaust port valve. D E F

22 Interface/Bracket Accessories Interface AC AV AU Y0 Y0 Y20 Y0 Y Y Y60 A Applicable model AC000 to AC020 AC2000 to AC20 AC20 to AC25 AC000 to AC0 AC00 to AC AC00-06 to AC-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 IR VEX SRP AMR L Bracket/ Interface with L Bracket M D ITV VBA Interface with L bracket L bracket L bracket Interface with L bracket A B C D E F R L Applicable model B0L B20L Y0L Y20L AC000 to AC020 AC2000 to AC20 B0L B0L B50L Y0L YL YL AC20 to AC25 AC000 to AC0 AC00 to AC AC00-06 to AC-06 B60L Y60L AC00, AC50, AC6000 AC20, AC5520, AC

23 Accessories T Bracket/ Interface with T Bracket Interface with T bracket T bracket T bracket B0T B20T B0T B0T B50T B60T Interface with T bracket Y0T Y20T Y0T YT YT Y60T A B C D E F H R L Applicable model AC000 to AC020 AC2000 to AC20 AC20 to AC25 AC000 to AC0 AC00 to AC00-06 to AC-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 Bracket For / For M/D For B B2 B2A BA BA B5A B6A A B C D F H J K L M N R t 2..2 Mounting thread M X 8 l (Round head Phillips screw) M X 8 l (Hexagon socket head cap screw) M5 X 0 l (Hexagon socket head cap screw) M5 X 0 l (Hexagon socket head cap screw) M6 X 0 l (Hexagon socket head cap screw) Applicable model 2000, 2000 M2000, D , 000 M000, D000 00, 00 M00, D , M00-06, D , , 6000, 60, , 6000 With 2 mounting screws..-2

24 Accessories Bracket/For / AC B220 AV AU Bracket/For, B20 B220 B20 B20 A B C D F øh J K L N R t B B B Appliable model 000, , , 25, , M2000 D , 0, 060 P000, 000, 0 M000, D000 IR VEX SRP B , 00-06,, -06, 60, , 00-06, -06 M00, D00 AMR M D ITV VBA.-2

Attachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface

Attachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface ttachments Piping dapter M X 0.8, / 8, /, / 8, /, /, asy maintenance. Makes it possible to attach and detach equipment without removing piping. -0 Piping adapter To order piping adapter with bracket, the

More information

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg) Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be

More information

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube swivels 0 Universal type permits 0 piping swivel.

More information

Odor Removal Filter Series AMF

Odor Removal Filter Series AMF Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odor in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical,

More information

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2. 18 Angular Gripper Cam Style Rack & Pinion Style Series / Cam actuation style is now standardized! 2.8-1 18 Angular Gripper 18 Angular Gripper Series / Cam Style Rack & Pinion Style Series / Series MHY/Cam

More information

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00 FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)

More information

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke. Magnetically Coupled Rodless Cylinder: Direct Mount ype Series ø, ø, ø, ø, ø, ø, ø, ø0, ø Direct mount type mm mm mm mm mm mm mm 0 0 mm mm 00 MB Piping type Both sides piping type Centralized piping type

More information

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet: abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.

More information

Flow rates to 750 l/min

Flow rates to 750 l/min FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)

More information

E8EB-N0C2B E8EB-N0B2B

E8EB-N0C2B E8EB-N0B2B Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree

More information

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Direct Operated Type Solenoid Operated Proportional Directional Control Valve Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.

More information

Identification Number

Identification Number Identification Number The specification of Micro Linear Way LWL is specified by the identification number, which consists of a model code, a size, a part code, a preload symbol, a classification symbol,

More information

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

180 Angular Gripper. Series MHY2/MHW2. Cam actuation style is now standardised! 5-241

180 Angular Gripper. Series MHY2/MHW2. Cam actuation style is now standardised! 5-241 18 Angular Gripper Cam tyle Rack & Pinion tyle eries MHY2/MHW2 Cam actuation style is now standardised! -21 18 Angular Gripper Cam tyle Rack & Pinion tyle eries MHY2/MHW2 eries MHY/Cam tyle Light and compact

More information

Flow rates to 475 l/min

Flow rates to 475 l/min FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass

More information

PHOENIX CONTACT - 04/2016. Features

PHOENIX CONTACT - 04/2016. Features Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.

More information

Direct-operated 2/2-way solenoid valves Type EV210B

Direct-operated 2/2-way solenoid valves Type EV210B Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Flow rates to 485 l/min

Flow rates to 485 l/min FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3 / - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient

More information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2 / way valves (solenoid actuated diaphragm with forced lifting) /4... Damped operation Operation without differential Suitable for vacuum igh flow rate For systems with low or fluctuating Brass body Wide

More information

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30 eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize

More information

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction

More information

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting 21/22 Series (general purpose valve) 21/22 Series NC (normally closed) type, NO (normally open) type Port size: Rc1 1/4 to Rc2, 32 to 50 flange iaphragm structure JIS symbol 21: Common specifications Item

More information

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation

More information

CKA Series. 3-way jaw thin chuck double acting/single acting. Operational stroke length: 5, 6, 7, 9, 20, 25, 30, 38mm.

CKA Series. 3-way jaw thin chuck double acting/single acting. Operational stroke length: 5, 6, 7, 9, 20, 25, 30, 38mm. G G B A S F J L L H LB N/ S/F Specifications Descriptions Size Cylinder bore size Operating method Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke

More information

Operating Instructions for Digital Manometer. Model: MAN-SD

Operating Instructions for Digital Manometer. Model: MAN-SD Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Commercial Generator Parts Catalog. PROTEC Series

Commercial Generator Parts Catalog. PROTEC Series Commercial Generator Parts Catalog PROTEC Series YD ÁÁ ÁÁ To avoid errors or delay in filling your parts order, always give the MODEL, SPEC NO. and SERIAL NO. from the Onan nameplate. For handy reference,

More information

Rotary modules.

Rotary modules. Rotary modules www.comoso.com www.comoso.com Rotary modules ROTARY MODULES Series Size Page Rotary modules RM swivel unit 156 RM 08 160 RM 10 162 RM 12 164 RM 15 168 RM 21 172 RM rotor 176 RM 50 180 RM

More information

Safety valve with unit approval type MV..X.., SV..X..

Safety valve with unit approval type MV..X.., SV..X.. Safety valve with unit approval type MV..X.., SV..X.. Operating pressure p max = 0 bar Flow Q max = 0 lpm Safety valve type CMVX 2.. with unit approval see D 77 TÜV These safety valves are intended for

More information

Model Selection 1. Process Valves. Air. Vacuum

Model Selection 1. Process Valves. Air. Vacuum Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air One-touch fittings

More information

PUSH TUBE STANDARD DUTY

PUSH TUBE STANDARD DUTY PUSH TUBE STANDARD DUTY ASSEMBLY / OWNER S MANUAL Part No: 15-0070 PUR223 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle Country

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37850 Application: HONDA 300 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent). Antistatic One-touch Fittings Tubing: Metric Size/Connection Thread: M, Rc, G, NPT, NPTF Series KA RoS One-touch fitting with antistatic prevention. One-touch IN/OUT connection. Possible to use from vacuum

More information

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: 78950 (50 ), 78954 (54 ), or 78960 (60 ) Application: All Terrain Vehicles Your safety, and the safety of others, is very important. To help you make

More information

Cooler-Bypass Thermostat Valve, Size 10

Cooler-Bypass Thermostat Valve, Size 10 Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,

More information

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno

More information

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components: SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine

More information

Precision Ball Screw/Spline

Precision Ball Screw/Spline 58-2E Models BNS-A, BNS, NS-A and NS Seal Outer ring Shim plate Seal Spline nut Seal Collar Shim plate Seal End cap Ball Outer ring Ball screw nut Outer ring Ball Retainer Retainer Outer ring Point of

More information

Model Selection 1. Process Valves

Model Selection 1. Process Valves Process Valves Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each product. Air, Inert gas

More information

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2 Series 4/PH MULTIFUNCTION SPOOL VALV air and solenoid air /-/ ISO 99/0 - Size ports / positions SPCIFICATIONS FLUID : or neutral gas, filtered, lubricated or not PRSSUR : 0,90 to + bar (can be used with

More information

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04 UK 80223776 / 00 11 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5

More information

P303 Pressure Regulator

P303 Pressure Regulator P0 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges Integral Monitoring The BelGAS P0 and P0H gas pressure reducing regulators are available with a true monitor regulator,

More information

ATV WP2 FRONT MOUNT PUSH TUBE

ATV WP2 FRONT MOUNT PUSH TUBE ATV WP2 FRONT MOUNT PUSH TUBE ASSEMBLY / OWNER S MANUAL Part No: 16-0000 MAN0352 Rev. 00 OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow component in the industry. Cycle

More information

Free Mount Cylinder Double Acting, Double Rod. ø6, ø10, ø16, ø20, ø25, ø32. How to Order. Action. D Double acting. Standard stroke (mm)

Free Mount Cylinder Double Acting, Double Rod. ø6, ø10, ø16, ø20, ø25, ø32. How to Order. Action. D Double acting. Standard stroke (mm) ouble Acting, ouble Rod eries CUW ø, ø, ø1, ø, ø2, ø How to Order CUW With auto switch CUW MBW Built-in magnet ouble rod 1 2 mm mm 1 mm mm 2 mm mm Action ouble acting Number of auto switches Nil 2 pcs.

More information

Flow rates to 590 l/min

Flow rates to 590 l/min LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

SHARK Snow Plow. 52 (132 cm) / 60 (152 cm) Complete system blade INSTRUCTIONS / ESTABLISHMENT

SHARK Snow Plow. 52 (132 cm) / 60 (152 cm) Complete system blade INSTRUCTIONS / ESTABLISHMENT SHARK Snow Plow 52 (132 cm) / 60 (152 cm) Complete system blade INSTRUCTIONS / ESTABLISHMENT OPERATING INSTRUCTIONS Congratulations! You ve just purchased the most durable plow system in the industry.

More information

Vane Type Rotary Actuators Series Variations

Vane Type Rotary Actuators Series Variations Vane Type Rotary Actuators Series Variations Vane Type Exterior CRB Series 0,, 0,, CRBU Series 0,, 0,, CRB Series, 6, 80, Has a compact body with exterior dimensions that do not change regardless of the

More information

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL FILE No. A10-023-1 REVISION 1 : Mar.2012 Re-edit version.( file volume down) Contents have NOT been changed. Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E

More information

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel. Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil

More information

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual 70 8TH AVE W PO BOX 7 SPENCER, IA 0 PHONE: 7-6-9 FAX: 7-6-08 SERVICE: 800-8- E-MAIL: ccac@cyclecountry.com www.cyclecountry.com A.R.M. PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER 0-00 BLACK MODEL

More information

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct-operated 2/2-way compact solenoid valves Type EV210A Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together

More information

EX-EMERGENCY LIGHT FITTINGS

EX-EMERGENCY LIGHT FITTINGS EX-EMERGENCY LIGHT FITTINGS nllk 0...N 1-36 W Plastic version for Zone 2 and Zone 21/22 The explosion-protected light fittings of the series nllk 0 N are conform to the requirements of the ATEX-Directive

More information

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22 .1 Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + C - nllk 09 18 W - 58 W for Zone and The lighting solution for high temperatures up to C The linear luminaires series nllk

More information

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014 Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM8004 80003223 / 00 05 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...4 3 Functions and features...5

More information

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2. 2.9 page 175 Namur 1/4 also called Namur 1 in accordance to VDI / VDE 3845. Namur 1/2 also called Namur 2. 2.9 Namur Valves + Selected models are available for low temperature application. Temperature-range:

More information

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820 Your purchase of this PEN VIBRATION METER marks a step forward for you into the field of precision measurement.

More information

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil Data sheet Solenoid valve s CSV 2 - CSV 22 (NC) and solenoid coil CSV is a direct or servo-operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. CSV valves are for

More information

Installation, Maintenance and Operating Instructions

Installation, Maintenance and Operating Instructions Trunnion-Design Ball Valves 12 20 (DN 300 500) Series 7150 12 (DN 300) Series 730S 12 20 (DN 300 500) Series 7300 14 24 (DN 350 600) Series 9150 14 24 (DN 350 600) Series 9300 Installation, Maintenance

More information

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18 erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it erie B. eries B. valves are shut-off ball valves

More information

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual 1. Please read this manual before installation or servicing. 2. Before installing or servicing, please ensure the line pressure has been relieved and

More information

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL Part No: 10-0550 OPERATING INSTRUCTIONS Congratulations! You ve just purchased one of the industry s top plow systems. The DRIFTER Plow System works great

More information

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop

More information

VOLUMEC. Valve Position Indicator 5

VOLUMEC. Valve Position Indicator 5 VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position

More information

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL PLOW MOUNT KIT FOR POLARIS RANGER P/N 34-3010 ASSEMBLY / OWNERS MANUAL Application PLOW PUSH FRAME NO. 34-0000 or 34-0070 Before you begin, please read these instructions and check to be sure all parts

More information

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7 ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan

More information

2/3 Port Valves for Fluid Control Model Selection 1

2/3 Port Valves for Fluid Control Model Selection 1 / Port Valves for Control Model Selection Model Selection For product specifications such as maximum operating pressure differentials and operating temperature ranges, refer to the relevent pages of each

More information

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional

More information

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.)

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Series VVX// The models VX// have been revised. For details, please refer to catalog no. ES0-A. Similar updating Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.) Courtesy of Steven Engineering,

More information

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Vortex flow meter. SVxxx / / 2015 Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating

More information

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS R Ballistic pendulum 11229.00 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D-37079 Göttingen 6 3.8 3.7 3.6 3.5 Phone +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Internet www.phywe.de

More information

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400 INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN 37851 Application: HONDA 400 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have

More information

Spare parts list UC-S

Spare parts list UC-S Spare parts list UC-S Contents Water inlet and tank heating Water softener Water drain, Mediamat Cyclo Circulating pump Wash + rinse; bottom Wash + rinse; top Boiler Dosage Panelling Cover plate, electrical

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:

More information

Odor Removal Filter. Model Note) 1 8, , , , 3 4. Model/Free Standing Type AMF800. Model/Piping Support Type AMF Port size

Odor Removal Filter. Model Note) 1 8, , , , 3 4. Model/Free Standing Type AMF800. Model/Piping Support Type AMF Port size dor emoval ilter Series os fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. Can

More information

Installation guide 862 MIT / MIR

Installation guide 862 MIT / MIR Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100

More information

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting. Manually Operated Directional s DM- / / DMG- / / / / hread Connection / Mounting Specifications hreaded Connections Numbers DM--C - DM--D - DM--D - DM--B - DM- -C - DM- -D - DM- -D - ( ) (.) (.) (.) (.)

More information

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features T E C H N I C A L I N F O R M A T I O N M A N U A L F O R T H E A 1 0 V 0 V A R I A B L E D I S P L A C E M E N T P U M P S A10V0 PUMP Features High Efficiency through load sensing (= fuel savings) Maximum

More information

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22) .2 Ex-Ceiling light fittings AB 8 / AB 5 LED / AB 5 / AB 12 NAV 7 (Zone 1, 2, 21, 22) The wall and ceiling light fixtures for particularly difficult operating conditions The impact-resistant and flameproof

More information

HARTING D-Sub Selection Guide

HARTING D-Sub Selection Guide HARTING D-Sub Selection Guide People Power Partnership D-Sub Selection Guide D-Sub Device Connectivity HARTING Connectivity & Networks generates solutions throughout the triad of Installation Technology,

More information

Observing Procedure for C11 GPS

Observing Procedure for C11 GPS Observing Procedure for C11 GPS By T. W. Fuller Preparation Customize observing list You can install a list of up to 25 custom objects in the telescope database ahead of time, so that you will have them

More information

Solenoid valves Type EVUL

Solenoid valves Type EVUL Data sheet Solenoid valves EVUL EVUL solenoid valves are designed to fit into compact refrigeration systems. Available in servo operated versions they can be applied in liquid, suction, and hot gas lines.

More information

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters Spin-on fi lters MPS series Maximum pressure up to bar - Flow rate up to 65 l/min 6 Spin-on fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by

More information

POWER PUSHER Snowplow

POWER PUSHER Snowplow May 15, 2013 Lit. No. 43682, Rev. 00 POWER PUSHER Snowplow 8' 72040; 10' 72045; Box Plow for Skid-Steer Loaders Owner's Manual and Installation Instructions Original Instructions CAUTION Read this manual

More information

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters High Pressure fi lters FMP series Maximum pressure up to 0 bar Flow rate up to 7 l/min High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH No. Part Name Quantity BOM code List Price Remark 1 Panel assembly 1 201132890609 2 Air filter 2 201132890704 5 Display box

More information

nufacturing Company, L.P San Felipe, Suite

nufacturing Company, L.P San Felipe, Suite Mini-Split Heat Pump Outdoor Unit RXS09LVJU RXS12LVJU RXS15LVJU RXS18LVJU RXS24LVJU REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is

More information

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials) Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:

More information

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure irect acting port solenoid valve for compressed air, manifold (special purpose valve) Series Universal type Port size: M, Rc/, Rc/ Refer to nding for more details. JIS symbol ommon supply / common exhaust

More information

High Pressure fi lters

High Pressure fi lters High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct

More information

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Kalinka Optics Warehouse User Manual  Kobra AK Side Mount Red Dot Sight Manual Kalinka Optics Warehouse User Manual www.kalinkaoptics.com Kobra AK Side Mount Red Dot Sight Manual CONTENTS 1. Introduction... 4 2. Purpose... 4 3. Specifications... 4 4. Components and Equipment Provided...

More information

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22) .1 Ex-Linear light fittings for fluorescent lamps nllk 08 18 W - 58 W (Zone, 1, ) The lighting solution for hazardous areas in Zones, 1 and The linear luminaires series nllk 08 for fluorescent lamps combines

More information