Maximum pressure 80 bar
|
|
- Cleopatra Bruce
- 5 years ago
- Views:
Transcription
1 Maximum pressure 80 bar F l o w r a t e s t o 0 0 l / m i n
2 LMP 0 Maximum pressure 80 bar F l o w r a t e s t o 6 0 l / m i n
3 Technical data LMP 0 Filter housing (Materials) Head: luminium Housing: ataphoresis painting ypass valve: rass/luminium Pressure LMP 0 length: Working pressure: 80 bar (8 MPa) Test pressure: 0 bar ( MPa) urst pressure: 90 bar (9 MPa) Pulse pressure fatigue test: cycles with pressure from 0 to 80 bar (8 MPa) Temperature From -5 to +0 NR seals series, compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. V series FPM seals, compatible with: Synthetic fluids type HS-HFR-HFS-HFU To ISO 9 Filter Element rea Filter element in stainless steel mesh Length Type U Values expressed in cm LMP 0 Style LMP 0 ypass valve Opening pressure.5 bar ±0% Other opening pressures on request. Δp Elements type Series N and W elements: 0 bar Oil flow from exterior to interior. Seals Standard NR Optional FPM Weights (kg) Length LMP0 -,6 LMP0 -,8 LMP0 -, LMP0 -,6 series series V Volumes (dm ) Length LMP0-0,75 LMP0-0,8 LMP0 -, LMP0 -,5 onnections Inlet/Outlet in Line LMP 0 Inlet/Outlet in Line + LMP second inlet port 90 Inlet/Outlet in Line + LMP 6 second outlet port 90 Inlet/Outlet in Line + LMP 8 outlet bypass port 90 ompatibility Housings compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. The filter elements are compatible with: Mineral oils to ISO 9, Synthetic fluids queous emulsions, water and glycol (series W required). 0,75 0,5 0,5 0,00 LMP 8 Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm to ISO 968. Δp varies proportionally with density. LMP 0 - Δp Housing / Style LMP
4 LMP LMP (plug not included) LMP 6 (plug not included) LMP - Δp Housing OUT / OUT 0,75 0,5 Style LMP Style LMP 0,5 0, LMP 6 - Δp Housings IN / - 0,75 0,5 Style LMP 6 0,5 0, Valves ypass valve pressure drop LMP 0 - LMP - LMP 6 Valves ypass valve pressure drop LMP
5 Filter Sizing orrect sizing of the filter must be based on a variable pressure drop depending on the application: return filter Δp from 0. to 0.6 bar filter on lubrication lines Δp from 0. to 0.5 bar off-line fluid power plants Δp from 0. to 0. bar off-line filter test benches Δp from 0. to 0. bar over-boost filter Δp from 0. to 0.6 bar The pressure drop calculation is performed by adding together the value for the housing and the value for the filter element. The pressure drop in the housing is proportional to the fluid density kg/dm ; all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop value is proportional to viscosity mm /s, the Y values in the catalogue are referred to viscosity of 0 mm /s. Sizing data for single cartridge, head at top Δp Tot. Δpc Filter housing Δpe Filter element Y Multiplication factor (see below) Q l/min = flow rate V = reference viscosity 0 mm /s (cst) V = operating viscosity in mm /s (cst) Δp Tot. = Δpc + Δpe Δpe = Y : 000 x Q x (V/V) Multiplication factor Y for definition of the pressure drop of filter elements. Reference viscosity 0 mm /s Filter Element Type b s o l u t e F i l t r a t i o n Nominal Filtration Nominal Filtration Series N Series N Series N P 0 P 5 M 5 U 0 6,5,6 8,57 5,759 5,6 0, 7,95,05 8,75 6, 5,066,798 8, 6,0,066,58 5,875,55,97,,86,598, 0,907,65,86,5 0,89 0, 0,5 0,067 0,0558 5
6 imensions LMP ,5,5 H onnection indicator Ø 80 5, Min. 5 6,5 6 60,6 5, onnection indicator (option) Length Filter H mm Filter fixing holes LMP onnections - E E E ouble filter fixing holes /8 UN x epth mm E M0 x epth mm E F G / G / NPT NPT SE SE 6 6
7 LMP LMP 6 onnections - G / G Lateral connections G / G / / NPT NPT / NPT / NPT E F SE SE 6 SE SE 7
8 LMP ,5,5 H 9 onnection indicator Ø 80 5, Min. 5 6,5 6 5, Length Filter H mm 60, onnections - Lateral connections G / G / G / NPT G / / NPT E NPT SE / NPT SE F SE 6 SE 8
9 Filter assembly LMP Ordering information LMP Example: LMP 0 0 N P0 Filter element U Example: U0 0 N P0 - Style Filter length 6 - Indicator port No (excluded LMP 8) 6 + (excluded LMP 8) 7 - Filter element - Valves 0 µm 06 6 µm 0 0 µm 6 6 µm 5 5 µm bsolute filtration Inorganic microfibre ßx (c) 000 S - Seals Without bypass valve (excluded LMP 8) With bypass valve Opening pressure:,5 bar With bypass valve Opening pressure: on request NR On request M5 5 µm M60 60 µm P0 0 µm P5 5 µm 8 - ollapse pressure Nominal Filtration Metal mesh Nominal Filtration ellulose 5 - onnection Type G / G / NPT 9 - Options N Δp 0 bar P0 MP Filtri standard Pxx ustomer request NPT E SE F SE 6 MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved. The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 9
10 LMP 0 0 Maximum pressure 80 bar F l o w r a t e s t o 0 0 l / m i n
11 Technical data LMP 0 Filter housing (Materials) Head: luminium Housing: ataphoresis painting ypass valve: rass/luminium Pressure LMP 0// length: Working pressure: 80 bar (8 MPa) Test pressure: 0 bar ( MPa) urst pressure: 80 bar (8 MPa) Pulse pressure fatigue test: cycles with pressure from 0 to 80 bar (8 MPa) Filter Element rea Filter element in stainless steel mesh Length Type U Values expressed in cm LMP 0 LMP Temperature From -5 to +0 ypass valve Opening pressure.5 bar ±0% Other opening pressures on request. Δp Elements type Series N and W elements: 0 bar Style LMP 0 Style LMP Oil flow from exterior to interior. Seals Standard NR Optional FPM series series V Weights (kg) Length LMP0 -,9 LMP0 -, LMP0 -, LMP0 -,9 Volumes (dm ) Length LMP0-0,75 LMP0-0,8 LMP0 -, LMP0 -,5 Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm to ISO 968. Δp varies proportionally with density. ompatibility Housings compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. The filter elements are compatible with: Mineral oils to ISO 9, Synthetic fluids queous emulsions, water and glycol (series W required). NR seals series, compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. V series FPM seals, compatible with: Synthetic fluids type HS-HFR-HFS-HFU To ISO 9 0,75 0,5 0,5 0,00 LMP 0/ - Δp Housing LMP LMP
12 LMP Type LMP Type Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm to ISO 968. Δp varies proportionally with density. LMP - Δp > > 0,75 Style LMP Type 0,5 0, ooler 6 LMP - Δp Housing with check valve bar setting ooler Style LMP Type 8 Type Type Valves ypass valve pressure drop LMP 0/LMP 6 LMP - Δp Housing with check valve bar setting Type Type
13 Filter sizing orrect sizing of the filter must be based on a variable pressure drop depending on the application: return filter Δp from 0. to 0.6 bar filter on lubrication lines Δp from 0. to 0.5 bar off-line fluid power plants Δp from 0. to 0. bar off-line filter test benches Δp from 0. to 0. bar over-boost filter Δp from 0. to 0.6 bar The pressure drop calculation is performed by adding together the value for the housing and the value for the filter element. The pressure drop in the housing is proportional to the fluid density kg/dm ; all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop value is proportional to viscosity mm /s, the Y values in the catalogue are referred to viscosity of 0 mm /s. Sizing data for single cartridge, head at top Δp Tot. Δpc Filter housing Δpe Filter element Y Multiplication factor (see below) Q l/min = flow rate V = reference viscosity 0 mm /s (cst) V = operating viscosity in mm /s (cst) Δp Tot. = Δpc + Δpe Δpe = Y : 000 x Q x (V/V) Multiplication factor Y for definition of the pressure drop of filter elements. Reference viscosity 0 mm /s Filter Element Type b s o l u t e F i l t r a t i o n Nominal Filtration Nominal Filtration Series N Series N Series N P 0 P 5 M 5 U 0 6,5,6 8,57 5,759 5,6 0, 7,95,05 8,75 6, 5,066,798 8, 6,0,066,58 5,875,55,97,,86,598, 0,907,65,86,5 0,89 0, 0,5 0,067 0,0558
14 imensions LMP 0 8 Indicator 0 onnection Indicator onnection Min. 5 H 0 onnections - Fixing holes Length Filter H mm E F G / G / NPT NPT SE SE 6 M0 x epth mm M0 x epth mm /8 UN x epth mm /8 UN x epth mm /8 UN x epth mm /8 UN x epth mm
15 LMP / 8 Indicator onnection Min. 5 H 0 Length Filter H mm LMP Plug not Included onnections - - G Fixing holes M0 x epth mm NPT /8 UN x epth mm F SE 6 /8 UN x epth mm 5
16 Ordering Information LMP0/ Filter assembly LMP Example: LMP 0 N P0 Filter element U Example: U0 0 N P0 - Style 0 - Filter length 6 - Indicator port Without indicator port With indicator port 7 - Filter element 0 µm 06 6 µm 0 0 µm 6 6 µm bsolute filtration Inorganic microfibre ßx (c) Valves 5 5 µm S - Seals Without bypass With bypass valve Opening pressure:,5 bar With bypass valve Opening pressure: on request M5 5 µm M60 60 µm P0 0 µm P5 5 µm Nominal Filtration Metal mesh Nominal Filtration ellulose NR On request 8 - ollapse pressure N Δp 0 bar 5 - onnections Type G / (not for LMP ) G 9 - Options P0 MP Filtri standard Pxx ustomer request / NPT (not for LMP ) NPT E SE (not for LMP ) F SE 6 MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 6
17 Ordering Information LMP Filter assembly LMP Example: LMP 0 N P0 Filter element U Example: U0 0 N P0 - Style - Filter length 5 - onnections Type G F SE Indicator port Without indicator port With indicator port - Valves Type - Without bypass valve heck valve bar heck valve bar Type - Without bypass valve G heck valve bar H heck valve bar Type - With bypass valve M heck valve bar N heck valve bar Type - With bypass valve 7 - Filter element 0 µm 06 6 µm 0 0 µm 6 6 µm 5 5 µm M5 5 µm M60 60 µm P0 0 µm P5 5 µm bsolute filtration Inorganic microfibre ßx (c) 000 Nominal Filtration Metal mesh Nominal Filtration ellulose Q R - Seals heck valve bar heck valve bar NR 8 - ollapse pressure 9 - Options N Δp 0 bar On request P0 Pxx MP Filtri standard ustomer request MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 7
18 LMP In-Line Suction and Return Filter 8 Maximum pressure 80 bar F l o w r a t e s t o 6 0 l / m i n
19 Technical data LMP Filter housing (Materials) Head: luminium Housing: ataphoresis painting ypass valve: rass/luminium Pressure LMP length: Working pressure: 80 bar (8 MPa) Test pressure: 0 bar ( MPa) urst pressure: 80 bar (8 MPa) Pulse pressure fatigue test: cycles with pressure from 0 to 80 bar (8 MPa) Filter Element rea Filter element in stainless steel mesh Length Type U Values expressed in cm LMP Temperature From -5 to +0 ypass valve Opening pressure.5 bar ±0% Other opening pressures on request. Δp Elements type Series N and W elements: 0 bar Oil flow from exterior to interior. Seals Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of 0.86 kg/dm to ISO 968. Δp varies proportionally with density. Standard NR Optional FPM Weights (kg) length LMP -,7 LMP -,9 LMP -, LMP -,7 series series V 8 6 LMP - Δp Housing > > Volumes (dm ) length LMP - 0,75 LMP - 0,8 LMP -, LMP -, ompatibility Housings compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. The filter elements are compatible with: Mineral oils to ISO 9, Synthetic fluids queous emulsions, water and glycol (series W required). NR seals series, compatible with: Mineral oils to ISO 9 - aqueous emulsions synthetic fluids, water and glycol. V series FPM seals, compatible with: Synthetic fluids type HS-HFR-HFS-HFU To ISO Valves ypass valve pressure drop LMP
20 Style - - E - F Style G - H bsolute filtration 0 bsolute filtration 0,8,,8,,, 0,7 0, ,8, bsolute filtration 6,8, bsolute filtration 6,, 0,7 0, bsolute filtration 5 bsolute filtration 5,8,,8,,, 0,7 0, Filter length
21 LMP Style - - E - F LMP Style G - H Pump Return Tank Tank Return Pump Symbols Style LMP Style E LMP Style G LMP Style LMP Style F LMP Style H LMP
22 Filter sizing orrect sizing of the filter must be based on a variable pressure drop depending on the application: return filter Δp from 0. to 0.6 bar filter on lubrication lines Δp from 0. to 0.5 bar off-line fluid power plants Δp from 0. to 0. bar off-line filter test benches Δp from 0. to 0. bar over-boost filter Δp from 0. to 0.6 bar The pressure drop calculation is performed by adding together the value for the housing and the value for the filter element. The pressure drop in the housing is proportional to the fluid density kg/dm ; all the graphs in the catalogue are referred to mineral oil with density of 0.86 kg/dm. The filter element pressure drop value is proportional to viscosity mm /s, the Y values in the catalogue are referred to viscosity of 0 mm /s. Sizing data for single cartridge, head at top Δp Tot. Δpc Filter housing Δpe Filter element Y Multiplication factor (see below) Q l/min = flow rate V = reference viscosity 0 mm /s (cst) V = operating viscosity in mm /s (cst) Δp Tot. = Δpc + Δpe Δpe = Y : 000 x Q x (V/V) Multiplication factor Y for definition of the pressure drop of filter elements. Reference viscosity 0 mm /s Filter Element Type b s o l u t e F i l t r a t i o n Nominal Filtration Nominal Filtration Serie N Serie N Serie N P 0 P 5 M 5 U 0 6,5,6 8,57 5,759 5,6 0, 7,95,05 8,75 6, 5,066,798 8, 6,0,066,58 5,875,55,97,,86,598, 0,907,65,86,5 0,89 0, 0,5 0,067 0,0558
23 imensions LMP Indicator 8 onnection Min. 5 H 9 7 Length Filter H mm F Threaded onnections - - G SE 6 Fixing holes M0 x epth mm /8 UN x epth mm
24 Symbols Style LMP Style E LMP Style G LMP Style LMP Style F LMP Style H LMP
25 Filter assembly LMP Ordering information LMP Example: LMP 0 N P0 Filter element U Example: U0 0 N P0 - Style - Filter length - Valves E F G 5 - onnections Type G F SE Indicator port No Port G /8 For pressure switch Port G / For pressure switch ifferential indicator port 7 - Filter element 0 0 µm 6 6 µm 5 5 µm 8 - ollapse pressure bsolute filtration Inorganic microfibre ßx (c) Seals H see SYMOLS (ref. to pages and ) NR V FPM N 9 - Option P0 Pxx Δp 0 bar MP Filtri standard ustomer request MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 5
26 Spare parts a b d c Pos. escription Qty FILTER Series LMP Filter assembly Filter element See order table See order table Seals Kit NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Gasket for indicator NR FPM d O-Ring for indicator O-R 050 Ø, x,78 Indicator Plug TH TV - Indicators See order table 6
27 Spare parts c d b a Pos. escription Qty FILTER Series LMP 0 Filter assembly Filter element See order table See order table Seals Kit NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Gasket for indicator NR FPM d O-Ring for indicator O-R 050 Ø, x,78 Indicator Plug TH TV - Indicators See order table 7
28 Spare parts d c b a Pos. escription Qty FILTER Series LMP - Filter assembly Filter element See order table See order table Seals Kit NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Gasket for indicator NR FPM d O-Ring for indicator O-R 050 Ø, x,78 Indicator Plug TH TV - Indicators See order table 8
29 ifferential indicators Order code Pressure: Working pressure 0 bar Pulse pressure fatigue test: cycles with pressure from 0 to 0 bar ( MPa) Example: NM 7 H P0 - Styles SERIES Z VISUL utton NR KR Electrical Electrical-Visual h. 0 6 NM Electrical IP 67 Z Visual U Visual - ifferential trip pressure Visual indicator with manual reset. Nylon signalling button. 6 bar ± 0% (with bypass filter) 7 5 bar ± 0% (without bypass filter) - Power supply voltage (only for style KR - only voltage ) Volt 0 Volt utton depressed position utton raised position, Red Weight: Tightening torque: = cartridge clean. = cartridge clogged. 8 gr. 60 Nm. - Seals H HNR Standard SERIES U VISUL Silicone membrane utton V FPM x Others on request 5 - Thermostat (only for style NM) h. 0 Without Electrical connector (only for style NM) onnector MP superseal series.5 onnector MP timer onnector EUTSH T 0--P onnector EUTSH T 0--P U indicator provide to accurate view indication of filter element condition. Visual signal utton depressed position utton rised position onnection G / Tightening torque: 65 Nm Weight: 8 gr Red button down: clean cartridge Red button up: clogging cartridge = cartridge clean. = cartridge clogged. Length electrical cable 0,5 m 7 - Option P0 MP standard 0
30 SERIES NR ELETRIL onnector EN /ISO 00 SERIES KR ELETRIL/VISUL 5 LE h. 0 N.. N.O. h. 0 LE N.. N.O. Switching type Max. contact rating Max power supply voltage Electrical connection EN able gland PG 9 Protection rating IP 65 onnection G / Tightening torque: Weight: N/O or N/ contacts (change over ontact) 0,8 / Vdc 0,7 / 5 Vdc 0Vac 65 Nm gr Switching type Max. contact rating Max power supply voltage N/O or N/ contacts (change over ontact) 0,8 / Vdc 0,7 / 5 Vdc Vdc - 5 Vdc/ac - 0 Vac Electrical connection EN visual indicator by LE GREEN LE = lean element. RE LE= locched element. able gland PG 9 Protection rating IP 65 onnection G / Tightening torque: Weight: 65 Nm gr SERIES NM ELETRIL Min. 0 Min. 0 Min. 0 h. 7 h. 7 h. 7 Length indicator NM Without thermostat With thermostat NM - NM h. 7 h. 7 NM - NM - NM T 50 Switching type Max. contact rating N/O contacts N/O thermostat 0,8 / Vdc 0,7 / 5 Vdc Max power supply voltage Max. 0Vdc Electrical connection onnector MP superseal series.5 onnector MP timer onnector EUTSH T 0--P onnector EUTSH T 0--P Lenght electrical cable 0,5 m Protection rating IP 67 onnection G / Tightening torque: 65 Nm Weight: 5 gr MP 0 UK 00
31 Recommended maximum flow rate - Pressure drop of filter assembly equal to Δp 0,7 bar. - Oil kinematic viscosity 0 mm /s (cst). - ensity 0,86 kg/dm. LMP 0/8 6 0 Filtration Filter length M5 P P M5 P P M5 P P M5 P P
32 New Headquarters: MP FILTRI S.p.. Italy Via Maggio, n Pessano con ornago (Milano) Italy Tel. +9.0/9570. Fax +9.0/ GRET RITIN MP FILTRI U.K. Ltd. ourton Industrial Park ourton on the Water Gloucestershire GL5 HQ UK Phone: Fax: GERMNY MP FILTRI GmbH m Wasserturm Heusweiler/Holz Phone: Fax: service@mpfiltri.de FRNE MP FILTRI FRNE Sas Parc d activités des hanteraines 8 rue du ommandant d Estienne d Orves, Immeuble 996 Villeneuve la Garenne - France Phone: +(0) Fax: +(0) sales@mpfiltrifrance.com http: // US MP FILTRI US Inc. 055 Quaker Pointe rive Quakertown, P 895 Phone: Fax: sales@mpfiltriusa.com N MP FILTRI N Inc. 80 Four Valley rive oncord Ontario anada LK 5Z Phone: Fax: mail@mpfiltricanada.com RUSSIN FEERTION MP FILTRI RUSSI Phone/Fax: +7(95) P.O. ox 756 Moscow, Russia mpfiltrirussia@yahoo.com HIN MP FILTRI (Shanghai) o. Ltd. 80 Lianxi Road, 8 ld - Floor Shanghai, Pudong 00 P.R. hina Phone: Fax: sales@mpfiltrishanghai.com INI & UE MP FILTRI INI & UE Phone: s.mishra@mpfiltri.com http: //
SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n
SERIES INLINE FILTERS LMP 0 Maximum pressure 60 bar Maximum flow to 0 0 l / mi n SERIES LMP 0 Working pre s s u re 60 bar Style S Style B B B D.I. D.I. A A Technical data Filter housing ( M a t e r i a
More informationSERIES. Maximum pressure 8 bar
SERIES Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n OLD MPF 00 NEW MPF 00 8 75 80 5-6 5,5 5,5 Nr. holes Ø 8,5 55 55 Nr. slots Ø 8,5 Up to: G NPT SAE 6 Up to: G / SAE 0 DIFFERENCE BETWEEN...
More informationLMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n
LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure
More informationCHINA MP FILTRI P.O. Box Shanghai Phone: Fax:
FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com
More informationFMM 050 uk :26 Pagina 5 (1,1) FMM 050
uk 6-07-006 9:6 Pagina 5 (,) 30 uk 6-07-006 9:6 Pagina 5 (3,) SRIS Working pressure 80 bar Style S Style Style T Style D 3 uk 6-07-006 9:6 Pagina 7 (,) Technical data Filter body ( M a t e r i a l s )
More informationFlow rates to 590 l/min
LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationWorking pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationFlow rates to 485 l/min
FB Maximum pressure 0 bar Flow rates to 8 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Steel Check valve:
More informationSERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
6 FMP SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Cast iron (chemical heat
More informationElement description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre
Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:
More informationSTAINLESS STEEL FILTER
STINLSS STL FILTR Style FZ Stainless Steel Pressure filter Technical data Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working
More informationWorking pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.
8 FB SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationPolígono Indutrial O Rebullón s/n Mos - España -
FP 5 Polígono Indutrial O Rebullón s/n. 646 - Mos - spaña - rodavigo@rodavigo.com SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Polígono Indutrial O Rebullón s/n. 646
More informationFMP :41 Pagina 5 (1,1) FMP
FMP 6-07-006 9:4 Pagina 5 (,) FMP 6 FMP 6-07-006 9:4 Pagina 5 (,) SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 FMP 6-07-006 9:4 Pagina 7 (,) Technical data Filter
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationPolígono Indutrial O Rebullón s/n Mos - España -
FB 8 Polígono Indutrial O Rebullón s/n. 646 - Mos - España - rodavigo@rodavigo.com SERIES FB Working pressure 0 bar Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Polígono Indutrial
More informationMPT Multifunction Multiport
MP Multifunction Multiport Maximum pressure 8 bar F l o w r a t e s t o 0 0 l / m i n echnical data housing (Materials) ead: luminium Cover: Nylon Bowl: Nylon Pressure Working pressure: 8 bar emperature
More informationmandata_us :43 Pagina 83 (1,1) FHB 82
8 FHB SERIES FHB Working pressure 4600 psi Style S Style B Style T Style D B B B B D.I. D.I. D.I. D.I. A A A A 8 Technical data Filter body ( M a t e r i a l s ) Head: Cast iron (chemical heat tre a t
More informationHigh Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min
High Pressure fi lters FHB series Maximum working pressure up to MPa (0 bar) - Flow rate up to 8 l/min High Pressure fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction
More information331 Low & Medium Pressure filters
Low & Medium Pressure fi lters LMP 00-0 & 0- series Maximum pressure up to 60 bar - Flow rate up to 70 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the
More information379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters
Low & Medium Pressure fi lters LMD series Maximum pressure up to 60 bar Flow rate up to 0 l/min 79 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationHigh Pressure fi lters
High Pressure fi lters FMM 00 series Maximum pressure up to 0 bar Flow rate up to l/min FHA 0 series Maximum pressure up to 60 bar Flow rate up to 0 l/min 9 High Pressure fi lters FILTER SIZING The correct
More informationHigh Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters
High Pressure fi lters FMP 09 series Maximum pressure up to 0 bar Flow rate up to 80 l/min 7 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationHigh Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters
High Pressure fi lters FHB series Maximum pressure up to 0 bar - Flow rate up to 8 l/min 8 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More information359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters
Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationLMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min
Low & Medium Pressure fi lters LMP 90090 series according to DIN 0 Maximum pressure up to 0 bar Flow rate up to 000 l/min Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be
More informationHigh Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters
High Pressure fi lters FMP series Maximum pressure up to 0 bar Flow rate up to 7 l/min High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending
More informationHigh Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters
High Pressure fi lters FHM series Maximum pressure up to 0 bar - Flow rate up to 0 l/min 67 High Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop
More informationHigh Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters
High Pressure fi lters FHA 0 series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 99 High Pressure fi lters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE FACTOR Page Introduction
More informationAIR BREATHER FILTERS. Temperature from -25 to +100 C
IR BRETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More information387 Low & Medium Pressure filters
Low & Medium Pressure fi lters LMD 000 & series Maximum pressure up to 6 bar Flow rate up to 90 l/min 87 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationDifferential indicators
Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively
More informationReturn fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters
Return fi lters FRI series Maximum pressure up to 0 bar - Flow rate up to 500 l/min 9 Return fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by
More informationSuction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters
Suction fi lters SF 00 series Flow rate up to 60 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,
More informationReturn fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min
Return fi lters series Maximum working pressure up to MPa (0 bar) Flow rate up to 000 l/min 0 Return fi lters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE FACTOR Page Introduction Calculation
More informationMetal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)
Metal oil filler and air Series T 46 4 5 6 4 ayonet connection Ø 46 7 8 46 Reservoir holes T46 (Materials) M5 - Cover: Chrome Plated Steel - Filter element: Impregnated paper Polyurethane 64-6 - Flange:
More informationSpin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters
Spin-on fi lters MPS series Maximum pressure up to bar - Flow rate up to 65 l/min 6 Spin-on fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by
More informationSuction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters
Suction fi lters & MPA MPM series Flow rate up to 87 l/min 7 Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example,
More informationAIR BREATHER FILTERS. Temperature from -25 C to +100 C
IR RETHER FILTERS The comprehensive series of breather filters makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. The function of
More informationMPF SERIES RETURN FILTER
MPF SERIES The series of filters MPF has specifically been designed for use on mobile applications, agricultural machinery and power units. The MPF filter range is suitable for flow rates up to 750 l/min.
More informationNylon oil filler and air breather filler caps
Series TP 0 Dimensions 6 Bayonet G / TP0 (Materials) - Cover/ringnut: Nylon - Filter element: Impregnated paper Polyurethane - Pressurisation valve: Nylon Galvanised Steel - Seal: Reservoir holes - Flange:
More informationSERIES. Accessories. s.p.a
New Headquarters : MP FILTRI S.p.. Italy Via Maggio, n. 000 Pessano con ornago (Milano) Italy Tel. +9.0/9570. Fax +9.0/957979570 email: sales@mpfiltri.com http://www.mpfiltri.com GRET RITIN MP FILTRI U.K.
More informationE 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e
R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e D e s c r i p t i o n Application In the return line circuits of hydraulic systems.
More informationVISUAL LEVEL INDICATORS
VIUL LEVEL INDICTOR LV... The level indicators series is available for both static and mobile applications; the construction materials used make it possible to guarantee service with wide temperature variations
More informationMetal air breather filter
Series S Metal air breather filter 4 H 5 6 7 H H S (Materials) Screw: Galvanised Steel Washer: Teflon Cover: Steel 4 Filter element: Impregnated paper 5 Ring: Galvanised Steel 6 Seal: R 7 Connection: nodised
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More informationMRH. Return Filters RETURN FILTER
MRH Return ilters RETUR ILTER Return ilters MRH MRH MPa (0 bar) Port sizes: / / low rates:.00 l/min TECHICAL ATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa ( bar) ursting pressure: 6 MPa
More informationCooler-Bypass Thermostat Valve, Size 10
Cooler-Bypass Thermostat Valve, Size Q max = l/min, p max = bar Temperature-controlled, integral relief function Description These direct acting bypass thermostat valves are size, temperature controlled,
More informationLCC***N**S. A/F (mm) Size G 1/2 G 3/4 G 1 G 1 1/4 G 1 1/2 G 2 G60. Ø hole for Expansion kit. Size. Diamètre G20 G26 G33 G42 G48.
eries L***N imensions L***N** L***N**K Ø E /F G F L***N***** (Materials) ody: Nylon Lens: Polyamide 3 ontrast screen: Nylon eals: NR Inorganic fibre 5 Expansion kit: rass NR L/N 5 3 5 L***N Example: L
More informationAir Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7
ir ooler Industry -LN -7 / -LN -7 / F-LN -7 Symbol General The -LN -7 air cooler series can be used in all areas where either oil or water-glycol is to be cooled with air. The coolers with an axial fan
More informationPRESSURE GAUGE SELECTORS
PRESSURE GUGE SELECORS Gauge isolator valves are designed to protect pressure gauges from pressure shocks when the pressure reading is not required; after each reading setting the selector to the closed
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us
H i g h P re s s u re i l t e r K i t s H 049 H 069 H 172 H 319 H 419 H 619 Operating pressure up to 8700 psi Nominal flow rate up to 118.9 gpm 40.95-3us e s c r i p t i o n pplication In the high pressure
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationCheck-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD
Check-Q-meter RE /0.0 /0 Replaces: 09.9 Type FD Nominal size... Series ax. Operating pressure 0 bar ax. Flow 0 l/min K9/ Table of contents Contents Page Features Functions Ordering details Symbols Functional
More informationVortex Flow Meters. RVL Series Vortex Flow Meter
TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000
More informationAttachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface
ttachments Piping dapter M X 0.8, / 8, /, / 8, /, /, asy maintenance. Makes it possible to attach and detach equipment without removing piping. -0 Piping adapter To order piping adapter with bracket, the
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationRFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min
Return Filters RFM RFM kpa (3 bar) Ports: 3/ 2 1/2 Flow rates: 0 l/min ECHNICAL DAA Max. working pressure: kpa (3 bar) Max. test pressure: 00 kpa ( bar) Bursting pressure: 1 MPa (10 bar) Fatigue test:
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationFlow sensor for liquid media type 210
Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationEVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES
TECNICAL DATA EVOTRON Operating range: from, -, m3/h with head of up to metres. Pumped liquid temperature range: from - C to + C. Working pressure: bar ( kpa). Protection class: IP X. Insulation class:
More information5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3
/ - / SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 99/ sizes, and Series Fluids air or inert gas, filtered, lubricated or not Operating pressure Pilot pressure Ambient
More informationFlow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min
RE 8/0.98 8/0.9 Flow Divider Type MHF, eries X (Differential lock) ize to up to 0 bar up to 00 /min RE 8/0.98 Replaces: 0.9 Characteristics: Double-acting (dividing and summating) flow divider Fixed division
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More information2-way proportional throttle valve for block installation
-way proportional throttle valve for block installation Types FES; FESE Sizes to Component series X Maximum operating pressure bar Maximum flow 800 l/min at Δp = 0 bar Table of contents Contents Page Features
More information4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)
4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design) Type 4WRL10...25 Sizes (N) 10, 16, 25 Unit series 3 Maximum working pressure P,, 350
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the ármán
More informationA wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.
Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil
More informationExternal gear pump Type G3, Series 3X
NS to 5 External gear pump Type G3, Series 3X Up to 2 bar Up to 5.2 cm 3 RE 039/07.00 Replaces: 03.00 Plain bearings for high loads Mono-block bearing New principle of hydrostatic gap compensation Drive
More informationK 080/12 F 10 K 3-2X/.. Features
RE 2 1/11.02 Replaces: 0.2 Fine throttle Type F Nominal sizes and Series 2X and 3X Maximum operating pressure 2 bar Maximum flow 0 L/min K 00/12 F K 3-2X/.. K 0/ F P 3-3X/.. Overview of contents Contents
More informationHigh-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet
High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N KSB Aktiengesellschaft All rights reserved. The contents
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDirect Operated Type Solenoid Operated Proportional Directional Control Valve
Direct Operated Type Solenoid Operated Proportional Directional Control Valve Features These four-way proportional directional control valves enable control of the forward and reverse motion of an actuator.
More informationVariable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design
rueninghaus Hydromatik Series 6, for open and closed circuits xial tapered piston, bent axis design Size 28...20 Nom. pressure up to 400 bar Peak pressure up to 40 bar RE 9606/0.97 RE 9606/0.97 replaces
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.9... 150 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán vortex
More informationCartridge Valves Technical Information
Quick reference CONTENTS CPF20... 8.2 CP600-5... 8. CP602-5... 8.4 20662 handle kit... 8.5 MP06... 8.6 MP2... 8.6 BC06... 8.9 BC0... 8.0 BC... 8. CP0-... 8. CP904-... 8.4 SC0... 8.5 SC... 8.6 DIN connectors...
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationAME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)
Super Mist Separator Series AME Series AME separates and absorbs aerosol state fine oil particles in compressed air and changes the oil lubricating compressed air to oilless equivalent air. It should be
More informationHigh Pressure Ball Valves
High Pressure all Valves 0,, 0, 0,000 psi (0 bar),000 psi (0 bar) 0,000 psi ( bar) ITOK Group ITOK GmbH (Headquarter) Sprendlinger Landstr., 0 Offenbach am Main, Germany Tel.: + 00 ax: + 00 ITOK, Inc.
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More information50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC
/ Hz ecocirc XL and XLplus high efficiency WET ROTOR circulators FOR COMMERCIAL HEATING AND COOLING applications ErP 9/1/EC Cod. 1971 Rev. C Ed.11/1 Lowara, ecocirc, Xylect are trademarks of Xylem Inc.
More informationZF Series Force Transducers
Data Sheet Series Force Transducers FEATURES 1 kn to 00 kn High accuracy For tensile or pressure forces Made of stainless steel Enclosure protection IP 67 DESCRIPTION The force transducers of the series
More informationCooling Water Flow Regulator
Temperature controlled, indirectly and directly actuated diaphragm valves / seat valves Port size G 3/8 to G DN 0 to DN 0 ontinuous regulation High accuracy No auxiliary energy required Technical data
More informationGear Wheel Flow Meter for Viscous Fluids
Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,
More informationGear Wheel Flow Meter for Viscous Fluids
Gear Wheel Flow Meter for Viscous Fluis measuring monitoring analysing Measuring range:. to 5 L/min Measuring accuracy: ±.3 up to ±1% of actual flow pmax: bar tmax: C rocess connection: G 1, G 3, G 1,
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationFlow sensor type 236 for liquid media
Flow sensor type 6 for liquid media Flow range 0.9... 0 l/min Nominal diameters DN 8 / 0 / / 0 / / Temperature measurement -0... + ÀC The type 6 is based on the type 0 but incorporates a brass housing.
More information