Flow sensor type 236 for liquid media
|
|
- Owen Curtis
- 5 years ago
- Views:
Transcription
1 Flow sensor type 6 for liquid media Flow range l/min Nominal diameters DN 8 / 0 / / 0 / / Temperature measurement ÀC The type 6 is based on the type 0 but incorporates a brass housing. The Vortex Sensor type 6 has a rugged construction of brass connection. This flow sensor is available with a larger variety concerning power supply and outputs. You can choose between various versions as integrated temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy. Flow measuring with voltage, current, pulse or frequency output Temperature non-sensitive measuring principle Excellent media resistance (measuring element not in contact with the media) Wide application temperature range Marginal loss of pressure Measuring element not sensitive to debris Direct temperature measurement in the medium Drinking water approval WRAS, ACS Huba Control type 6 - Technical data subject to change - Edition 09/08 /9
2 Technical Overview Flow measurement Measuring principle Vortex Piezoelectric sensor element l/min Nominal diameters DN 8 / 0 / / 0 / / Accuracy at < 0% fs (water) < % fs Accuracy at > 0% fs (water) < % measuring value Response time Immediately. Therefore suitable for spigot use. Frequency output (unfiltered) Signal delay < 00 ms Response time < ms Frequency output (unfiltered) Analogue output Signal delay < s Response time < 00 ms Operating conditions Medium Suitable for heating circuit water with the usual additives Drinking water Media Temperature Ambient Ambient (x... 0 ma) Storage (for lifetime) (for lifetime) Max. pressure and (for 600 hours) medium temperature (for hours) (max. test pressure) Cavitation The following equation is valid to prevent cavitation: P abs outlet / P difference >. Materials in contact with medium (FDA-conform) Sensor paddle Case Sealing material other medium on request < + ÀC ÀC ÀC ÀC bar at +0 ÀC 6 bar at +00 ÀC bar at + ÀC bar at +0 ÀC 8 bar at +0 ÀC ETFE Red brass / PA6T/6I (0% GF) EPDM (perox.) (for drinking water) FPM Electrical connection Protection standard Connector Mx IP 6 Weight with thread with thread M with thread G DN 8 with condensation protection ~ 60 g - ~ 06 g DN 0 with condensation protection ~ 00 g ~ g ~ 07 g DN with condensation protection ~ 0 g - ~ 0 g DN 0 with condensation protection ~ 78 g - ~ 90 g DN with condensation protection ~ 0 g - ~ 707 g DN with condensation protection - - ~ 696 g Test / Admissions Electromagnetic compatibility CE conformity acc. to EN 66-- Drinking water approval WRAS, ACS Plastic parts with TW and W70 approval Packaging Single packaging Multiple packaging Minimum life span on high flow rate and high temperature Temperature in ÀC Temperatur in C Durchfluss Flow in in %% Std hours 0 hours Std 00 hours Std 0. year Jahr Jahr year 0 year Jahre /9 Huba Control type 6 - Technical data subject to change - Edition 09/08
3 Analogue output - Electrical overview Temperature measurement Measuring principle Resistance PT ÀC T = 0 ÀC μ 0. Accuracy class B D EN T 0 ÀC μ 0. μ 0.00 * ΔT ÀC V Accuracy μ 0. μ 0.00 * ΔT Calculation temperature T (ÀC) = +0 ÀC 0 V * U_T - ÀC ÀC... 0 ma Accuracy μ 0. μ 0.00 * ΔT Calculation temperature T (ÀC) = I_T - ma 6 ma * 0 ÀC - ÀC Electronic Voltage output Current output Dual power output Power supply.... VDC 8... VDC 0... VDC Output flow (Q) anaogue signal V... 0 ma... 0 ma Output temperature (T) signal V... 0 ma Load agianst or < 6 ma / < 00 nf ) < (U - 8 V) / 0 ma < (U - 0 V) / 0 ma Current consumption load free (I) < ma Electrical reliability Short circuit, reverse voltage and external voltage protected within the admissible supply voltage. Analogue output - Nominal diameters dependent variables DN Measuring range [l/min] [ ] L Flow range [m/s] Pressure drop ),) U V * min I L [ ma * min] * Q * Q..000 Characteristic line formula current output Q V = I * (I - ma) Characteristic line formula voltage output Q V = U * U * Q * Q * Q * Q * Q Legend Q V Volume flow rate [l/min] U Coefficient voltage output [(l/min) / V] I Coefficient current output [(l/min) / ma] U Voltage [V] I Current [ma] Version Nominal diameters and flow range Ouput / power supply Electrical connection Sealing material Tube connection 6 7 Analogue output - Order code selection table 6. X X X X X X X Flow 9, Flow and temperature (PT000) 8, Flow and temperature (x V) 6 Flow and temperature (x... 0 ma) DN l/min. 0 8,G DN l/min. 0 DN l/min. DN l/min.,g DN l/min. 0,G DN l/min.,g DN l/min. Analogue output V.... VDC 9,8,6 Analogue output... 0 ma 8... VDC 9,8 Analogue output... 0 ma 0... VDC Connector Mx -polet (with condensation protection) 9, -pole (with condensation protection) 8,6, EPDM Ethylene propylene rubber (peroxidically cross-linked) FPM ) Fluoro elastomer (DN 8, 0 - G ½; DN - G ¾; DN 0 - G ; DN - G ¼; DN - G ½) Brass with outside thread M (DN 0 - G ¾) M G (DN 8 - G ¾ ; DN 0 - G ; DN - G ; DN 0 - G ¼; DN - G ½) G ) against only ) incl. xdi inlet and outlet side ) Pv in Pa; Q in l/min ) No drinking water approval Huba Control type 6 - Technical data subject to change - Edition 09/08 /9
4 Frequency output (filtered) and pulse output - Electrical overview Temperature measurement Measuring principle Resistance PT000 class B D EN ÀC T = 0 ÀC μ 0. Accuracy Class B D EN T 0 ÀC μ 0. μ 0.00 * ΔT Temperature influences Self-heating at temperature sensor /mw Conduction resistance to connector 0.8 Ω Electronic Power Supply.7... VDC Output flow (Q) Level height (open collector) < > U - 0. V Output temperature (T) Resistant signal PT000 class B D EN 607 Load agianst or > kω / < 0 kω Current consumption load free (I) < ma Electrical reliability Short circuit, reverse voltage and external voltage protected within the admissible supply voltage. Frequency output (filtered) and pulse output - Nominal diameters dependent variables DN Measuring range [l/min] Flow range [m/s] Pressure drop ),) ff [(l/min) / Hz] at Hz Quantity per pulse I [ml] (pulse) Pulse (pulse output) [/l] * Q * Q * Q * Q * Q * Q * Q Characteristic line formula frequency output filtered ( Hz, other frequency on request) Q V = ff * f Pulse I/min = pulse * I * 60 s 000 Legend Q V Volume flow rate [l/min] ff Coefficient frequency output filtered [(l/min) / f] f Frequency [Hz] Version Nominal diameters and flow range Output / power supply Electrical connection Sealing material Tube connection 6 7 Frequency output (filtered) and pulse output - Order code selection table 6. X X X X X X X Flow 9 Flow and temperature (PT000) 8 DN l/min. 0 8,G DN l/min. 0 DN l/min. DN l/min.,g DN l/min. 0,G DN l/min.,g DN l/min. Frequency output (filtered).7... VDC 6 Pulse output.7... VDC 7 Connector Mx -pole (with condensation protection) 9 -pole (with condensation protection) 8 EPDM Ethylene propylene rubber (peroxidically cross-linked) FPM ) Fluoro elastomer (DN 8, 0 - G ½; DN - G ¾; DN 0 - G ; DN - G ¼; DN - G ½) Brass with outside thread M (DN 0 - G ¾) M G (DN 8 - G ¾ ; DN 0 - G ; DN - G ; DN 0 - G ¼; DN - G ½) G ) incl. x Di inlet and outlet side ) Pv in Pa; Q in l/min ) No drinking water approval /9 Huba Control type 6 - Technical data subject to change - Edition 09/08
5 Frequency output (unfiltered) - Electrical overview Temperature measurement Measuring principle Resistance PT000 class B D EN ÀC T = 0 ÀC μ 0. Accuracy Class B D EN T 0 ÀC μ 0. μ 0.00 * ΔT Temperature influences Self-heating at temperature sensor /mw Conduction resistance to connector 0.8 Ω Electronic Power Supply.7... VDC Output flow (Q) Level height (push-pull) < > U - 0. V Output temperature (T) Resistant signal PT000 class B D EN 607 Load agianst or < ma / < 00 nf Current consumption load free (I) < ma Electrical reliability Short circuit, reverse voltage and external voltage protected within the admissible supply voltage. Frequency output (unfiltered) - Nominal diameters dependent variables DN Tube connection Measuring range [l/min] Flow range [m/s] Pressure drop ),) Quantity per fs [ml] Frequency range unfiltered [Hz] Q 0 [l/min] f [(l/min) / f] 8,G * Q * Q -0. G,M * Q -0. G,M * Q -0. G * Q -0. G * Q -0. G * Q Characteristic line formula frequency output unfiltered Q V = f * f + Q 0 Formula quantity per pulse [litres/pulse] Quantity = f * Q V Pulse 60 * (Q V - Q 0 ) Legend Q V Volume flow rate [l/min] Q 0 Axis intercept [l/min] f Coefficient frequency output [(l/min) / f] f Frequency [Hz] Quantity litres Quantity per pulse Pulse pulse 6 7 Frequency output (unfiltered) - Order code selection table 6. X X X X X X X Version Flow 9 Flow and temperature (PT000) 8 DN l/min. 0 8,G DN l/min. 0 DN l/min. Nominal diameters and DN l/min.,g flow range DN l/min. 0,G DN l/min.,g DN l/min. Output / power supply Frequency output (unfiltered).7... VDC Electrical connection Connector Mx - or -pole (condensation protection) 9 - or -pole (condensation protection) 8,6 Sealing material EPDM Ethylene propylene rubber (peroxidically cross-linked) FPM ) Fluoro elastomer (DN 8, 0 - G ½; DN - G ¾; DN 0 - G ; DN - G ¼; DN - G ½) Tube connection Brass with outside thread M (DN 0 - G ¾) M G (DN 8 - G ¾ ; DN 0 - G ; DN - G ; DN 0 - G ¼; DN - G ½) G ) incl. x Di inlet and outlet side ) Pv in Pa; Q in l/min ) No drinking water approval Huba Control type 6 - Technical data subject to change - Edition 09/08 /9
6 Accessories (Accessories supplied loose) Order number Straight-wire box for connector Mx with cable -pole 00 cm 60 Corner-wire box for connector Mx with cable -pole 00 cm 60 Straight-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Corner-wire box for connector Mx with cable -pole 00 cm (with temperature) 6 Straight-wire box for connector Mx screwing terminal -pole 0 Dimension diagram DN 8..9 G ½ 77 DN 8 G..7 G ¾ 77 DN0. G ½ 86 9 DN 0 M. G ¾ 86 9 DN 0 G 7. G 86 9 DN.9 G ¾ 87 DN G 9. G 87 DN G 0 7 DN 0 G G ¼ 0 7 DN G ¼ 0 DN G 0 7. G ½ 0 DN G ½ Tube mounting instructions Consider the following to ensure the correct function of the sensor. Only diameter changes from large to small are allowed. Avoid repeated elbows in the same level at entryside minimum xdn for alternative elbows min. 0.xDN für ideale 90À rümmungen mit min. R.8xDN 6/9 Huba Control type 6 - Technical data subject to change - Edition 09/08
7 Electrical connection Connector Mx without temperature measurement Hz Hz Pullup < 0kΩ > kω A V Q Frequency output unfiltered Frequency output filtered Pulse output Current output Voltage output Connector Mx with temperature measurement T Ω T Hz Ω Hz Pullup < 0kΩ > kω T Ω T A Q T A A frequency output with temperature measurement PT000 Frequency output filtered Pulse output Current output with temperature measurement PT000 Current output with temperature measurement... 0 ma T Ω T Q V Voltage output with temperature measurement PT000 T Q V Voltage output with temperature measurement V V Pin Colour brown blue black brown white blue black gray Huba Control type 6 - Technical data subject to change - Edition 09/08 7/9
8 Influence of glycol With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity >.8 cst) in order to reach a measuring accuracy of % fs in the range of.8 - cst and of % in the range of - cst (υ = viscosity in cst). Definition of viscosity of glycol-water-compound inematic inematische Viskosität Ethylenglykol Wasser viscosity ethylene glycol water inematic inematische Viskosität Propylenglykol Wasser viscosity propylene glycol water Temperature Temperatur in C ÀC % 0% 0% 0% 0% 0% 60% 70% Temperature Temperatur in C ÀC % 0% 0% 0% 0% 0% 60% viscosity Viskosität in cst in viscosity Viskosität in cst in Definition of respond threshold Q min Definition of characteristic line formula Q V = k f * f + Q 0 Minimal Minimal detek rbarer detectable flow Durch uss Ein uss Influence der on Viskosität viscocity Q0auf Q 0 - Minimaler flow Durch uss in l/min in l/min 0 0 DN0 DN DN0 DN DN characteristic Q0 in ennlinienformel line formula in l/min DN0 DN DN0 DN DN viscosity Viskosität in cst in cst viscosity Viskosität in cstin cst Formula respond threshold Q min in l/min < DN 0 not possible DN0: Q min = υ DN: Q min = υ +. DN0: Q min = υ +.0 DN: Q min = υ DN: Q min = υ +.0 Formula characteristic line for Q > Q min in l/min < DN 0 not possible Frequency output (unfiltered): DN0: Q = f * f 0.0υ DN: Q = f * f 0.υ + 0. DN0: Q = f * f 0.υ + 0. DN: Q = f * f 0.80υ DN: Q = f * f 0.8υ + 0. Frequency output (filtered): DN0: Q = 0.0 * f 0.0υ DN: Q = 0.00 * f 0.υ + 0. DN0: Q = * f 0.υ + 0. DN: Q = 0.0 * f 0.80υ DN: Q = 0.0 * f 0.8υ + 0. Impulse output: DN0: Q = 0.00 * #Pulse/s 0.0υ DN: Q = * #Pulse/s 0.υ + 0. DN0: Q = * #Pulse/s 0.υ + 0. DN: Q = 0.07 * #Pulse/s 0.80υ DN: Q = 0.0 * #Pulse/s 0.8υ + 0. Voltage output V: DN0: Q =. * UOut 0.0υ DN: Q =.0 * UOut 0.υ + 0. DN0: Q = 8. * UOut 0.υ + 0. DN: Q =.0 * UOut 0.80υ DN: Q =.0 * UOut 0.80υ Current output... 0 ma (I in ma): DN0: Q =.000 * (I ma) 0.0υ DN: Q =. * (I ma) 0.υ + 0. DN0: Q =. * (I ma) 0.υ + 0. DN: Q = 9.7 * (I ma) 0.80υ DN: Q =.000 * (I ma) 0.80υ /9 Huba Control type 6 - Technical data subject to change - Edition 09/08
9 Huba Control AG Headquarters Industriestrasse 7 6 Würenlos Telefon + (0) Telefax + (0) info.ch@hubacontrol.com Huba Control AG Niederlassung Deutschland Schlattgrabenstrasse 7 Walddorfhäslach Telefon +9 (0) Telefax +9 (0) info.de@hubacontrol.com Huba Control SA Succursale France Rue Lavoisier Technopôle Forbach-Sud 760 Forbach Cedex Téléphone + (0) Télécopieur + (0) info.fr@hubacontrol.com Huba Control AG Vestiging Nederland Hamseweg 0A 88 AD Hoogland Telefoon + (0) 0 66 Telefax + (0) 0 77 info.nl@hubacontrol.com Huba Control AG Branch Office United ingdom Unit Berkshire House County Park Business Centre Shrivenham Road Swindon - Wiltshire SN NR Phone + (0) Fax + (0) info.uk@hubacontrol.com 9/9 Huba Control type 6 - Technical data subject to change - Edition 09/08
OEM Flow sensor type 235 for liquid media
OEM Flow sensor type 235 for liquid media Flow range 0.9... 240 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 / 32 Temperature measurement -40... +125 ÀC The type 235 is based on the type 200 but incorporates
More informationFlow sensor for liquid media type 210
Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationFlow sensor for liquid media type 230
Flow sensor for liquid media type 0 Flow range.8... 0 l/min Nominal diameters DN 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the Kármán vortex trail. You can choose
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the ármán
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.9... 150 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán vortex
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the pressure measuring cell is fully
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationAIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control
AIR PREPARATION ELECTRONICALLY CONTROLLED PRESSRE REGLATING ALE (PROPORTIONAL PRESSRE REGLATING ALE) SERIES control Description Abb. Port size Recommended Type Data Sheet No. flow (l/min)* airfit tecno
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More informationE8EB-N0C2B E8EB-N0B2B
Slim Sensor CSM DS_E 1 Ideal for Workpiece Position and Original Checking The to 1 kpa model can be used for workpiece position checking. The to 1MPa model is ideal for original pressure checking. Degree
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationTHM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist
THM80X Series Feature Application IP67 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Linear adjustment temperature & humidity by computer,
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationLinear measuring technology
Their extremely robust construction, their high IP69k protection level and their wide temperature range make these new draw wire encoders particularly reliable and durable. Their flexibility and adaptability
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08 Introduction The HAH1BVW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications
More informationDimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial
Incremental Encoder DRS/DRS, face mount flange up to 8,2 Dimensional drawing face mount flange radial Incremental Encoder Connector or cable outlet Protection class up to IP s TTL and HTL Zero-Pulse-Teach
More informationDVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C
Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0.4. 000 l/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼... G, ¼" NPT..." NPT
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationDRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach
NEW DRS : Incremental encoders, number of lines and zero pulse width freely programmable DRS : s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing
More informationBTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters
FEATURES 5 mbar to 0 bar, 0. to 50 psi differential pressure...6 or...0 ma Precision temperature compensated and calibrated Rugged aluminium housing Female /8" BSP and /8" NPT fittings MEDIA COMPATIBILITY
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function SITRANS LH00 Transmitter for hydrostatic level U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59
More informationPressure. 1 Fitting PA R - N R2
INTERNAL STRUCTURE (R 1/4) 4 1 2 3 FEATURES High corrosion resistance and drip-proof construction port attachment made of Proven IP-65 grade gauge body (IP-65 in accordance with IEC) Standard product provides
More informationCompact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.
Flow sensors www.ifm.com/mid Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm. For industrial applications Volumetric flow sensor efector mid. High-precision
More informationD5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder
with incremental encoder Draw wire encoder A40 Traverse speed max. 0.8 m/s The draw wire system A40 with incremental encoder excels with its compact construction. RoHS Compact and simple Measuring length
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More informationTF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationImformation of C091D series
Imformation of C09D series The QTY of contacts is -pin to -pin, the connection method for the thread type, pinhole connections for welding type, press-fit and PCB type. This series of connectors to prevent
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationS95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation
S95.U0 / S95.U Head mounted temperature transmitters, programmable, Pt 00 (RTD), thermocouples, electrical isolation Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling
More informationŸ 9-50-way std density Ÿ way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g.
Ÿ 9-50-way std density Ÿ 15-78 way high Density Ÿ Mixed layout constructions ( e.g. 7W2, 9W4, 17W5) Ÿ Power constructions in 20A -40A ( e.g., 3W3, 5W5, 8W8) Ÿ Feed-through capacitor & pi filter constructions
More informationVDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems
06 EN - Straight valves VDN.. Angle valves VEN.. Reverse angle valves VUN.. ACVATIX TM Radiator valves NF norm, for -pipe heating systems VDN.. VEN.. VUN.. Valve bodies made of brass, mat nickel-plated
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch
DRUCK & TEMPERATUR LEITENBERGER GMBH DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 00: standard: 0. % FSO option: 0. % FSO Nominal pressure: from 0... 00 mbar up to
More informationW 9 L: Laser photoelectric switches: small, light and reliable
W 9 Laser photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 9 L: Laser photoelectric switches: small, light and reliable The
More informationInstallation guide 862 MIT / MIR
Installation guide 862 MIT / MIR in combination with: 864 MTT or 863 MRT or (dual) spot element November 2005 Part no. 4416.232_Rev3 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100
More informationTF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.
TF / TF -Ex Field mounted temperature transmitters, PROFIBUS PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN P R O F I PROCESS FIELD BUS B U S Input Resistance thermometer (,, -wire
More informationHYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC
HYGRASGARD AFF - LC AFTF - LC sensors, calibrateable, with and active passive output Quality product for HVAC sector, accuracy % r.h. The calibrateable room humidity and temperature sensor HYGRASGARD KFF
More informationSINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol
SINEAX VK 66 for RTD and TC inputs, with HART procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application II () G SINEAX VK 66 is a two-wire head-mounted transmitter.
More informationDigital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5
Pressure Sensor E8CC with Built-in Microcomputer and Digital Display and New E8CB General-purpose Model Withstands a of 490 kpa (5 kgf/cm 2 ) and highly reliable. Incorporates a two-turn adjuster ensuring
More informationProximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-000(India) Tel : 0-797575 Fax : 0-79757 E-mail : sales@ashalain.com Proximity Ideal for High Temperatures and Cleaning
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationSINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol
with PROFIBUS-PA procol for installation in the terminal head of a temperature sensor DIN 79, shape B Application 00 II () G FISCO The SINEAX VK 66 is a temperature transducer for use in aumation systems
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-T... Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of
More informationAC axial compact fan
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8-0 Fax +49 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for
More informationThe Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:
The basic PC software is supplied free with the recorder. There is an additional charge for the extensive Data Acquisition Software supplied with communication of RS-232/422/485 or Ethernet. The Ordering
More informationBMXART0814 analog input module M340-8 inputs - temperature
Product data sheet Characteristics BMXART0814 analog input module M340-8 inputs - temperature Main Range of product Product or component type Electrical connection Input output isolation Input level Analogue
More informationThermal-Magnetic Circuit Breaker 2210-S2..
Thermal-Magnetic Circuit Breaker -S.. Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1 Picture of product with pencil Introduction The HC6H family is for the electronic measurement of DC, AC or pulsed currents in high power
More informationVOLUMEC. Valve Position Indicator 5
VOLUMEC Valve Position Indicator 5 2 KRACHT CORP. 8600 S Wilkinson Way Unit A Perrysburg, OH 43551 USA P +1 419 874 1000 F +1 419 874 1006 flowmeters@krachtcorp.com www.krachtcorp.com VOLUMEC Valve Position
More informationSurface-mounting Thermostats ATH Type Series
Page 1/9 urface-mounting Thermostats ATH eries k enclosure protection IP 54 k tested to IN EN 14597 (replacing IN 3440) Brief description Thermostats control and monitor thermal processes. Instruments
More informationPHOENIX CONTACT - 04/2016. Features
Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals.
More informationMIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:
Electromagnetic Flowmeter Compact for conductivity liquids measuring monitoring analysing MIK Range from liquids, acids and caustic solutions: 0.0-0. 3-700 l/min frequency-, switching-, analogue output
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8-0 Fax +9 798 8-0 info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationBMXART0814 analog input module M340-8 inputs - temperature
Characteristics analog input module M340-8 inputs - temperature Complementary Analog/Digital conversion Analogue input resolution Input impedance Permitted overload on inputs Common mode rejection Differential
More information5-V Low-Drop Fixed Voltage Regulator TLE 4269
5-V Low-Drop Fixed Voltage Regulator TLE 4269 Features Output voltage tolerance ±2 % 15 ma current capability Very low current consumption Early warning Reset output low down to V Q = 1 V Overtemperature
More information4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE) RE 9035/. Replaces: 05. 1/1 Type 4WRPEH 6 Size 6 Unit series X Maximum
More informationAC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More information- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen
INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications
More informationA wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.
Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil
More informationFLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:
abc instruments international FLT5A Thermometer Land Instruments International Dronfield, S18 1DJ England Telephone: (1246) 417691 Facsimile: (1246) 41585 Email: infrared.sales@landinst.com Internet: www.landinst.com
More informationLED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data
Product description Downlights High-flux LED module Low tolerances for colour temperatures (MacAdams 4) Compact design Excellent thermal management 1 NTC for temperature control High-power LED module in
More informationMODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range
Liquid Inexpensive Microflow Coriolis Flowmeter CoriMate Ⅱ MODEL: CR002, CR003, CR004 GENERAL Based on the knowledge and experience on Coriolis technologies OVAL has gained over many years, the Corimate
More informationFL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact
FL ballasts EL HE PC TC PRO sr 1/2x11 42 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 T Nominal life-time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per
More informationVortex Flow Meters. RVL Series Vortex Flow Meter
TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000
More informationW 30 Photoelectric proximity switches: Clear signals even with low remission
W 0 Photoelectric proximity switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic W 0 Photoelectric proximity switches: Clear signals even with low remission In addition,
More informationLinear actuator Econom 2. Our intelligent model: Econom 2. Econom 2
Linear actuator Econom 2 Our intelligent model: Econom 2 Econom 2 Linear actuators Econom 2 Description Applications Facts The users of the Econom 2 come from many different industries: From architects
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Thermal-Magnetic Circuit Breaker 0-S... Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed
More informationThermal-Magnetic Circuit Breaker 2210-S2...
Description One, two and three pole thermal-magnetic circuit breakers with trip free mechanism and toggle actuation (S-type TM CBE to EN 6094/IEC 94). Designed for panel or plug-in mounting. Available
More informationW250: Compact photoelectric switch series for a broad range of applications
W0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W0: Compact photoelectric switch series for a broad range of applications
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationDOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max
Oscillation Flowmeter for gases measuring monitoring analysing DOG1/3 Measuring ranges: 0.2 20... 200 20000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 400 Material: cast iron,
More informationATEX/IECEx RTD temperature probe
Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or
More informationGM4275 GM4275 V2.03. Features. Description. Applications. Block Diagram WIDE INPUT RANGE 5V LOW DROPOUT REGULATOR WITH RESET FLAG
Description The GM4275 series of fixed output, micro-power voltage regulators is designed for applications which require wide input voltage range up to 45V. The GM4275 is an excellent choice for the use
More informationSilicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6
Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230 KTY 16-6 KTY 10-x KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 Features Temperature dependent resistor with positive temperature coefficient
More informationISEmax CAM40/CAS40. Technical Information
Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works
More informationPhoto-electric sensors1
References Three-wire DC, solid-state output Teach mode - + Sensing distance (Sn) m Depending on Function Output Connection Reference Weight NO/NC Prograable PNP Pre-cabled XUDAPSML 0.00 M XUDAPSMM 0.00
More informationV 12: Miniature photoelectric switches in M 12 housings
Lichtschranken Photoelectric Baureihe switcheswl 7- Photoelectric proximity switches Photoelectric reflex switches : iniature photoelectric switches in housings Through-beam photoelectric switches They
More information359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters
Low & Medium Pressure fi lters LMP 909 series Maximum pressure up to 0 bar Flow rate up to 00 l/min 9 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationLEDlight 20 W Universal dimmable series
LEDlight 20 W Universal dimmable series L05011i2 / L05011i3 / L05011i4 Lumotech technology Lumotech LED drivers are designed to efficiently power and control LED solutions for general lighting applications.
More informationImpedance relay and protection assemblies
RXZK 21H, 22H, 23H 509 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970175) (SE970184) Features Micro-processor based impedance relay with R and X settings
More information