Vortex Flow Meters. RVL Series Vortex Flow Meter
|
|
- Amos Sanders
- 5 years ago
- Views:
Transcription
1 TM Vortex Meters RVL Series Vortex Meter pplications: Water/Wastewater I Water: Semiconductor, Institutional I Water Skids Semiconductor Equipment Slurry hemical Processing RINE FEERTE IN. ISO 900 : 000 FILE N NPT connection Flare-end connection Wafer connection Toll Free: 888-5RINE
2 RVL Series Liquid Meter The RVL series meter utilizes vortex-shedding technology to provide a repeatable flow measurement accurate to ±% of full scale. The meter has no moving parts, and any potential for fluid contamination is eliminated by the meter's corrosion-resistant all plastic construction. The meter includes a compact -wire (4-0 m) or -wire (0-5 Vdc or pulse) transmitter, contained within a conveniently replaceable plug-in electronics module. ll electronics are housed in a corrosion-resistant enclosure. Unlike meters containing metal or moving parts, the RVL is perfect for aggressive or easily contaminated fluids. pplications range from ultra-pure water to highly corrosive chemicals and slurries. Units may be re-calibrated and the meter output span reprogrammed in the field. Operating Principle Software Utility (Optional) n optional software utility kit is available to configure the RVL 4-0 m or 0-5 Vdc outputs. (The pulse output is not field configurable.) Part number RVS0-954 contains a RS 9-pin cable, software, TTL to RS converter and a board interface cable. The program enables easy configuration of span, damping and units of measurement. Operation of the RVL vortex flow meter is based on the vortex shedding principle. s fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations. These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-0 m, 0-5 Vdc or pulse signal. The frequency of the vortices is directly proportional to the flow rate. This results in extremely accurate and repeatable measurements using no moving parts. Material Selection When choosing the best flow meter for a process, it is necessary to review the fluid to be measured, its concentration, the minimum and maximum operating temperatures, operating pressure, fluid viscosity, suspended particles, density of the fluid and, most importantly, expected flow range. One advantage of utilizing a RVL vortex flow meter is that there are no gaskets or elastomers in the meter. Therefore, one need only be concerned with the thermoplastic material used in body construction. In a thermoplastic piping system, the material chosen for the flow meter should match that of the pipe wherever possible. hemical ompatibility - Excellent - Good - Fair - Severe effect ompatibility hemical PV PVF PV Polypropylene luminum Hydroxide hlorine Water Fuel Oils Hydraulic Oil Hydrochloric cid 7% Hydrofluoric cid 0% Isopropyl lcohol Nitric cid (oncentrated) Phosphoric cid (>40%) Potassium Hydroxide Propylene Glycol Sulfuric cid (0-75%) N/ N/ N/ N/ Line Fluids Many factors may affect the capability of a meter to measure the flow of specific fluids accurately. ifferent solutions have varying effects on meters. For instance, heavy particle suspension will wear down internal parts on some meters or cause sensing inaccuracies for non-obtrusive metering systems. For vortex flow meters, high viscosities tend to dampen the formation of vortices and reduce the effective range. Particles and internal bubbles do not usually affect vortex meters. PVF models typically work very well in slurry services, though slurries containing grit can wear down the bluff body over a period of time. lso, long fibers can catch and build up on the bluff, decreasing accuracy. Standard factory calibration is for tap water at SSU ( cst) viscosity and ambient temperature. Viscosity above cst will raise the minimum readable flow rate, reducing rangeability. The effect is linear to viscosity. No adjustments are required for specific gravities up to.0. Liquids with high specific gravities will adversely affect the permissible amount and duration of overrange flow. The following chart indicates the reduction of range based on viscosity: Viscosity and Rangeability Weight Minimum Maximum Range cst cst cst 4 cst 5 cst 6 cst : 6: 4: :.4: : Tel:
3 RVL Series In-Line Meters for Liquids Specifications Measured: Liquids onnection: utt or NPT thread Turndown Ratio: : (except ¼" meter size; 8:) ccuracy: ±% of full scale, 4-0 m and 0-5 Vdc; ±% of full scale, frequency pulse Repeatability: ±0.5% actual flow Output Signal: 4-0 m, 0-5 Vdc or frequency pulse (source-sink driver; source /.5 sink; typical output resistance 0 Ohms) Power Supply: to 0 Vdc Enclosure: NEM 4X (IP 66) Response Time: seconds minimum, step change in flow ertifications: S File: 505 S Standard. No. O-M and No. 4-M imensions: Inches (mm) Pressure - Temperature Rating Maximum Fluid Temperature F Maximum Operating Pressure PSIG (bar) PV PV PVF (6.4) 4 (.6) 6 (4.) 0 (8.) 40 (.7) 0 (8.9) = Not Recommended Minimum and Maximum Rates /4 / -/ /" NPT Female onduit onnection /4 / -/ (97) (97) (97) (00) (99) (09) (5) (5) () (8) (94) (04) () () (50) 5.75 (46) 5.75 (46) 5.88 (49) 6. (58) 6.60 (68) (6) (0) (4) (0) (8) (48) 4.87 (4) 4.87 (4) 4.87 (4) 5.09 (9) 6.4 (58) 6.77 (7) () () (7) (5) (76) NPT/utt EN Part Number onstruction Vortex (In-Line) Meters for Liquids - Piezoelectric Technology d d d e f g h i Racine Standard Vortex Liquid Meter Size ody Style ody Material Output Options isplay Part Number: RVL ddd Line Size 05) /4" 050) /" 075) " 00) " 50) -/" 00) " Max 5 GPM (8.9) 5 GPM (56.8) 5 GPM (94.6) 50 GPM (89.) 00 GPM (78.5) 00 GPM (757.) e ody Style / End onnections ) utt End onnection (available with PVF material only) N) NPT (Male) Thread f ody Material ) PV ) PV 4) PVF g Output X) 4-0 m (standard) P) Frequency Pulse V) 0-5 Vdc h Options ) lass 000 leaning H) High Temperature rated: 0 F (95 ) S) Stainless Steel Tag ) -Pin onnector i isplay ) Top mount L ) ottom mount L ) Right mount L 4) Left mount L Multiple options may be selected High Temperature option ONLY available with PV and PVF body materials Not available with display Fax:
4 RVL Series Wafer Meters for Liquids Specifications Measured: Liquids onnection: Wafer (mounts between flanges) Turndown Ratio: : ccuracy: ±% of full scale, 4-0 m and 0-5 Vdc; ±% of full scale, frequency pulse Repeatability: ±0.5% actual flow Output Signal: 4-0 m, 0-5 Vdc or frequency pulse (source-sink driver; source /.5 sink; typical output resistance 0 Ohms) Power Supply: to 0 Vdc Enclosure: NEM 4X (IP 66) Response Time: seconds minimum, step change in flow ertifications: S File: 505 S Standard. No. O-M and No. 4-M Pressure - Temperature Rating Maximum Operating Pressure PSIG (bar) Maximum Fluid Temperature F PV (8.9) = Not Recommended PP PV PVF 4 (.6) 00 (6.9) 0 (8.9) 40 (.7) 0 (8.9) 90 (6.) 0 (8.9) Minimum and Maximum Rates Size Minimum Maximum (inches) / -/ imensions: Inches (mm) PVF /" NPT Female onduit onnection Size / -/ 5.85 (49) 5.90 (50) (5) 6.7 (6) 6.88 (75).78 (0).94 (4).9 (0).50 (8).88 (48).50.0 (5).0 (5).5 (57).6 (67). (8) 4.5 (08).75 (44). (54).47 (6).5 (8) 4.00 (0) 5.4 () Part Number onstruction Vortex (Wafer) Meters for Liquids - Piezoelectric Technology d d d W f g h i Racine Standard Vortex Liquid Meter Size ody Style ody Material Output Options isplay Part Number: RVL W ddd Line Size 050) /" 075) " 00) " 50) -/" 00) " 00) " Max 5 GPM (56.8) 5 GPM (94.6) 50 GPM (89.) 00 GPM (78.5) 00 GPM (757.) 00 GPM (5.5) e ody Style W) Wafer (mounts between flanges) f ody Material ) PV ) PV ) Polypropylene 4) PVF g Output X) 4-0 m (standard) P) Frequency Pulse V) 0-5 Vdc h Options ) lass 000 leaning H) High Temperature rated: 0 F (95 ) S) Stainless Steel Tag ) -Pin onnector i isplay ) Top mount L ) ottom mount L ) Right mount L 4) Left mount L Multiple options may be selected High Temperature option ONLY available with PV and PVF body materials Not available with display 4
5 RVL Series In-Line Flare End Meters for Liquids Specifications Measured: Liquids onnection: Tube (flare-end)* Turndown Ratio: /" size = 8: " size = : " size = : ccuracy: ±% of full scale, 4-0 m and 0-5 Vdc; ±% of full scale, frequency pulse Repeatability: ±0.5% actual flow Output Signal: 4-0 m, 0-5 Vdc, or frequency pulse (source-sink driver; source /.5 sink; typical output resistance 0 Ohms) Power Supply: to 0 Vdc Enclosure: NEM 4X (IP 66) Response Time: seconds minimum, step change in flow ertifications: S File: 505 S Standard. No. O-M and No. 4-M * Requires two flare tubing nuts (not included) Pressure - Temperature Rating Maximum Fluid Temperature F Maximum and Minimum Rates Tube Size (inches) / Maximum Operating Pressure PSIG (bar) PVF 95 0 (.4) 60 7 (.6) 8 67 (4.6) Minimum Maximum /" NPT Female onduit onnection imensions: Inches (mm) Size /. (). ().44 (7) 6.5 (59) 6.5 (59) 6.59 (67) 4.87 (4) 4.66 (8) 5.4 (8) Part Number onstruction Vortex (In-Line Flare End) Meters for Liquids - Piezoelectric Technology d d d d F 4 g h i Racine Standard Vortex Liquid Meter Size ody Style ody Material Output Options isplay Part Number: RVL F 4 ddd Line Size 050L) /" 075L) " 00L) " 5 Max 5 GPM (8.9) 5 GPM (56.8) 5 GPM (94.6) e ody Style/ End onnections F) Flare End onnection (tube) f ody Material 4) PVF g Output X) 4-0 m (standard) P) Frequency Pulse V) 0-5 Vdc h Options ) lass 000 leaning S) Stainless Steel Tag ) -Pin onnector i isplay ) Top mount L ) ottom mount L ) Right mount L 4) Left mount L Multiple options may be selected Not available with display Tel:
6 RVL Series Pressure rop vs Rate In-Line Meters for Liquids PRESSURE ROP (psid) PRESSURE ROP (Millibar) Wafer Meters for Liquids In-Line Flare End Meters for Liquids PRESSURE ROP (psid) PRESSURE ROP (Millibar) PRESSURE ROP (psid) PRESSURE ROP (Millibar) ivision of Racine Federated Inc. TM 865 Washington venue Racine, WI US 008 Racine Federated Inc.,all rights reserved. Racine is a trademark of Racine Federated Inc. R VL- 000 /08 Racine Meter Group 6 Toll Free (US & anada): 888-5RINE (57-46)
Pro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationTarget Insertion Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationDMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm
DMP Pi Precision Pressure Transmitter pressure ports and process connections with flush welded stainless steel diaphragm accuracy according to IEC 600: 0, % FSO Nominal pressure from 0... 00 mbar up to
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationDirect-operated 2/2-way compact solenoid valves Type EV210A
Data sheet Direct-operated 2/2-way compact solenoid valves Type EV210A EV210A covers a wide range of small, directoperated 2/2-way solenoid valves for use in industrial machinery. The compact design together
More informationField IT 50T Series Transmitters
Data Sheet SS/G/A_ Field IT 0T Series Transmitters gauge/absolute pressure transmitter Ranges: -00 to 0000kPa - to 00bar -. to 6000psi Base accuracy : 0.% (BFSL) Chemical Vapour Deposition (CVD) technology
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationPressure transmitters for industrial applications MBS 32 and MBS 33
Data sheet Pressure transmitters for industrial applications MBS 32 and MBS 33 The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications, and offer
More informationFLOW SENSOR FOR LIQUID MEDIA Serie 210
FLOW SENSOR FOR LIQUID MEDIA Serie 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 60 bar Output
More informationMX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E
OMPT ND USER FRIENDLY MX Series Metal Tube Type Variable rea Flowmeter OUTLINE MX Series flowmeter is the metal tube type variable area flowmeter having the unified face-to-face dimension. The compact
More informationCoriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM
MAXIFO TM Features MaxiFlo Coriolis Mass Flowmeter series MCM is a mass flow meter that measures mass flow, density and temperature of liquids, slurries and gases. And it even measures oil content in water.
More informationAbsolute encoders multiturn
elektronischer electronic multiturn, Multiturn, magnetic magnetisch Sendix M66 / M68 (shaft / hollow shaft) The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature
More informationSolenoid valves 2/2-way direct-operated type EV210A
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valves 2/2-way direct-operated type EV210A EV210A covers a wide range of small, direct-operated 2/2-way solenoid valves for use in industrial machinery.
More informationDS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm
Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar
More informationIts modular concept allows to build up a ball valve for any degree of automation and any kind of application
Type 2657...59 DN 10 up to 80 mm; Plastic; 2/2 way dvantages/benefits ntegrated pilot valves, position feed-back and limit switches available Customized system solutions with Burkert valves & sensors With
More informationLMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n
LMP 0 Style S Style Maximum pressure 60 bar F l o w r a t e s t o 7 0 l / m i n 6 Technical data Filter housing (Materials) Head: luminium Housing: nodised luminium ypass valve: Nylon - Steel Pressure
More informationED 701 General Industry Pressure Transmitter
ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationElectromagnetic Flowmeter
Overview Flokal B.V. smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology. It s being widely used in industries such
More informationDirect-operated 2/2-way solenoid valves Type EV210B
Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance
More informationA wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.
Solenoid Valve Waterhammer-Free, 0- PSI /-Way; NPT - NPT; 0- PSI Advantages/Benefits Type 63 Waterhammer-free Low noise Zero differential pressure ompact design with high flow rates Low maintenance oil
More informationFundamentals of Flow Metering
Technical Data Sheet 00816-0100-3031 Fundamentals of Flow Metering A reliable flow indication is dependent upon the correct measurement of A and V. If, for example, air bubbles are present in the fluid,
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
Reference Manual 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com Reference Manual 405 and 1595 405 Compact Orifice Series and 1595 Conditioning
More informationSECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:
SECTION 1 - WHAT IS A BTU METER? ISTEC BTU Meters measure energy usage by multiplying flow rate and temperature difference. As the water (or other liquid) passes through these lines, the multi-wing turbine
More informationTurbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas
Turbine Meter TRZ 0 PRODUCT INFORMATION Reliable Measurement of Gas TURBINE METER TRZ 0 Method of operation, Construction Method of operation The TRZ 0 turbine meter is a flow meter suitable for gas measurement
More informationSITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181
Siemens AG 09 SITRANS F flowmeters System information Overview Siemens offers two types of ultrasonic flowmeters, in-line flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationDS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.
DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 and 1595 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test
More informationSeries P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015
INJECTION CHECK VALVE COUPLING NUT DISCHARGE TUBING 4 FUNCTION VALVE SPACER, E.P.U PUMP HEAD RETURN LINE (PRESSURE RELIEF) METERING PUMP HOUSING STROKE KNOB SUCTION FITTING SUCTION TUBING WEIGHT POWER
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the ármán
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationValve Products ADEX Series Valves
atalog 000-2US X alves X is a miniature low power consumption solenoid valves, ideal for powering small to mid-sized pneumatic actuators used in automation and process applications. X's versatility is
More information405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book and Flow Handbook www.rosemount.com 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Book NOTICE Read
More informationBulkhead Fitting Product Guide
1/2" TO 3" PV OMPRSSION FITTING * oes not come with bulkhead fitting MTRILS Robust PV Upper and Lower ody onstruction PV ell lass 12454 per STM 1784 Stainless Steel Wave Spring 17-7 PH Stainless Steel Fits
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications Type 8221 can be combined with Perfect for demanding applications in the hygienic industry (CIP and SIP compatible) Variants available for usage over a wide
More informationSERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
6 FMP SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Cast iron (chemical heat
More informationWorking pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.
5 FP SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Technical data Filter body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment)
More informationFMP :41 Pagina 5 (1,1) FMP
FMP 6-07-006 9:4 Pagina 5 (,) FMP 6 FMP 6-07-006 9:4 Pagina 5 (,) SERIES FMP Working pressure 80 bar Style S Style Style T Style D Style V Style Z 7 FMP 6-07-006 9:4 Pagina 7 (,) Technical data Filter
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationFlow sensor for liquid media type 210
Flow sensor for liquid media type 0 Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC In comparison to the OEM flow sensor (type 00), the type 0 is available
More informationIN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases
IN-FLOW Industrial Style Digital Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in low flow thermal and Coriolis Mass Flow Meters/Controllers,
More informationPressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27
Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for
More informationFull Metal Variable Area Flow Meter and Counter
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing Special versions up to 600 bar Measuring range: 10-100...00-000 L/h water 0.3-3.0...-0
More informationtekcor TKC Multivariable Coriolis Flow Sensors
Sensing the pulse of industry Technical Data Sheet & General Specifications tekcor TKC Multivariable Coriolis Flow Sensors The tekcor TKC Series principle was initiated by tekflo sensors engineers, who
More informationFlow rates to 590 l/min
LM 400-40 - 4 Maximum pressure bar Flow rates to 590 l/min Technical data housing (Materials) ead: nodized luminium ousing: nodized luminium Manifolds: Steel - Painted black ypass valve: Steel -way ball
More informationFlow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.
FVone-NP- 00/ (Push-in type) Recommended for: DN and bigger Required accessory: Threaded installation bush able type Optional accessory: PTFE sealing ring Locking set FVone-NP- 0/0 (Screw-in type) Recommended
More informationOEM Flow sensor type 235 for liquid media
OEM Flow sensor type 235 for liquid media Flow range 0.9... 240 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 / 32 Temperature measurement -40... +125 ÀC The type 235 is based on the type 200 but incorporates
More informationFMM 050 uk :26 Pagina 5 (1,1) FMM 050
uk 6-07-006 9:6 Pagina 5 (,) 30 uk 6-07-006 9:6 Pagina 5 (3,) SRIS Working pressure 80 bar Style S Style Style T Style D 3 uk 6-07-006 9:6 Pagina 7 (,) Technical data Filter body ( M a t e r i a l s )
More informationFlow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.
Flow Monitoring Technologies in Oil and Gas Don Ford, Technical Specialist Spartan Controls Ltd. Agenda Flow technologies at a glance Oil and Gas at a glance Select Flow Technologies in Depth Differential
More informationIndustrial Pressure Transmitter
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationMaximum pressure 80 bar
Maximum pressure 80 bar F l o w r a t e s t o 0 0 l / m i n LMP 0 Maximum pressure 80 bar F l o w r a t e s t o 6 0 l / m i n Technical data LMP 0 Filter housing (Materials) Head: luminium Housing: ataphoresis
More informationRoHS. Versatile. X g. X 2 e
s IN8, - and The inclinometers of the IN8 series allow measuring inclinations in the range of ±85 or -dimensional inclinations up to 0. With their high robustness, their protection level up to max. IP9k
More informationHydraulic Pressure NAH Applications. Features. New generation available - refer to
NAH 8 Hydraulic Pressure Transmitter New generation available - refer to www.trafag.com/h70 Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for
More informationInformation Technology Solutions Neptune Datasheet
Information Technology Solutions Neptune Datasheet Suspended Solids Analyzer Neptune is the first purpose built in-situ analyzer for measuring the suspended solids of slurries. Specifically developed for
More informationFluid Cooling Industrial PF Series
Fluid Cooling Industrial PF Series 0916 STAINLESS STEEL PLATES CARBON STEEL FRAME Performance Notes Carry bar Gasketed plate style heat exchanger Tie rods Oil to water applications High performance Pressure
More informationIndicate Positive, Negative or Differential, Accurate within 1%
SERIES 2000 MAGNEHELIC DIFFERENTIAL GAGES Indicate Positive, Negative or Differential, Accurate within 1% RUBBER RELIEF PLUG WILL UNSEAT ITSELF WHEN GAGE IS OVERPRESSURIZED.025 [.64] SPACE CREATED BY 3
More informationMaterials of Construction and Chemical Compatibility for Sensing and Control Products
ADVANCED MATERIALS HANDLING TECHNICAL NOTE Materials of Construction and Compatibility for Sensing and Control Products INTRODUCTION Entegris Sensing and Control products are designed for use in highly
More informationCHINA MP FILTRI P.O. Box Shanghai Phone: Fax:
FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com
More informationPROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF CHEMICALLY AGGRESSIVE LIQUIDS PROCESS REFRACTOMETER PR-23-W/PR-23-M SB:PR-23-W/M
PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF CHEMICALLY AGGRESSIVE LIQUIDS PROCESS REFRACTOMETER PR-23-W/PR-23-M SB:PR-23-W/M TYPICAL APPLICATIONS K-Patents Saunders Body PR-23-W and K-Patents
More informationFlow rates to 475 l/min
FMP Maximum pressure 0 bar Flow rates to 7 l/min Technical data PRSSUR FILTR Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: Brass
More informationFlow sensor for liquid media type 230
Flow sensor for liquid media type 0 Flow range.8... 0 l/min Nominal diameters DN 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the Kármán vortex trail. You can choose
More informationISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER
ISOCON-6 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 0-0)
More informationPolígono Indutrial O Rebullón s/n Mos - España -
FP 5 Polígono Indutrial O Rebullón s/n. 646 - Mos - spaña - rodavigo@rodavigo.com SRIS FP Working pressure 40 bar Style S Style Style T Style D Style V Style Z 5 Polígono Indutrial O Rebullón s/n. 646
More informationInstrumentation & Data Acquisition Systems
Instrumentation & Data Acquisition Systems Section 5 -Flow Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 The Perfect Flowmeter Infinite rangeability / turndown with negligible uncertainty
More informationPermanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate
Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Stationary ultrasonic clamp-on system for
More informationMaximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00
FMM 00 Maximum pressure 0 bar Flow rate to l/min FHA 0 Maximum pressure 60 bar Flow rate to 0 l/min Technical data FMM 00 Filter housing (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel
More informationHigh Power Contacts - Up to 850A
8 Series igh Power Contacts igh Power Contacts - Up to 850 esigned to meet the harshest military requirements where high power and shielding are needed. 3 aluminum shell sizes available Size 19 (450 max);
More informationFlow Measurement in Pipes and Ducts COURSE CONTENT
Flow Measurement in Pipes and Ducts Dr. Harlan H. Bengtson, P.E. COURSE CONTENT 1. Introduction This course is about measurement of the flow rate of a fluid flowing under pressure in a closed conduit.
More informationSELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes
SELECCIÓN DE CAUDALIMETROS Tablas de Fabricantes Flow Meter Selection Table http://www.instrumart.com/content.aspxcontentid=219 Página 1 de 1 17/09/2007 KEY Best for this application OK with some exceptions
More informationElement description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre
Style FZ Stainless Steel Pressure filter Technical data element Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working pressure:
More informationFlow rates to 750 l/min
FP Maximum pressure 0 bar Flow rates to 70 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical heat treatment) Bypass valve: AISI L (FP 00-0)
More informationOEM Flow sensor for liquid media type 200
OEM Flow sensor for liquid media type 200 Flow range 0.9... 150 l/min Nominal diameters DN 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor type 200 is based on the Kármán vortex
More informationDM70 Hand-Held Dewpoint Meter for Spot-Checking Applications
DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed
More informationDM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability
DM70 Hand-held Dewpoint Meter Truly Fast Response - Superior Long-term Stability DM70 - When Dry Air Is Important The Vaisala DM70 Hand-held Dewpoint Meter offers stable and fast measurement for industrial
More informationApplicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.
TOKICO TURINE METER GS-F211E- Overview Turbine meter has an excellent performance with its distinctive structure. Comparing with the flow meter using other method, it has compact and lighter design and
More informationFluoropolymer Fittings Hyper Fitting
Fluoropolymer Fittings yper Fitting Series Q S Q QR Quadruple seal construction (PT.) efore tightening Nut Tubing support Insert bushing Tubing fter tightening Quadruple sealing parts New PF ourtesy of
More informationOperating Instructions for Digital Manometer. Model: MAN-SD
Operating Instructions for Digital Manometer Model: MAN-SD 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5
More informationTransmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level
Overview Function s are for measuring the liquid levels in wells, tanks, channels and dams. Sensor Diaphragm p U const. U +2 (brown) I EM I - (blue) 0, U B s are submersible sensors for hydrostatic level
More information- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen
INSTRUCTION MANUAL FA 510 The CS dew point sensor FA 510 with 3-wire technology 4 20 ma and RS 485 output enables a reliable and long-term stable monitoring of the dew point in industrial applications
More informationELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina
ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT By Dr. Crainic Monica Sabina Luxten Lighting Company AEM Branch Office Gas and Water Meters Research Department 26 Calea Buziaşului300693 Timişoara
More informationPRODUCT CATALOGUE PREssURE switch
PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they
More informationSTAINLESS STEEL FILTER
STINLSS STL FILTR Style FZ Stainless Steel Pressure filter Technical data Style In-Line filter: FZ 00-0 FZP 0 FZ 0 FZP 6 FZX 0 Manifold mounting: FZ 0 FZM 0 Max. working pressure: 700 bar Max. working
More informationCipriani Harrison Valves Corp.
Butterfly Valve pplication Stainless steel hygienic butterfly valves are used in process piping systems for isolation and control. Butterfly valves operate either manually or automatically. Working Principle
More information98 Series Backpressure Regulators and Relief Valves
9 Series Backpressure Regulators and Relief Valves Bulletin.:9 November 09 W TYPE 9H W TYPE 9LD Figure. Typical 9 Relief Valves Introduction W TYPE 9HD The 9 Series (Figure ) is used for backpressure or
More informationIntegral V-Cone Flowmeter VD series
TRANSMITTER DIRECTLY MOUNTED! SIMPLE AND EASY INSTALLATION Integral V-Cone Flowmeter VD series OUTLINE VD series Integral V-Cone Flowmeter is a differential pressure type flowmeter. Unlikely to existing
More informationThermal Mass Flow Meter for Gases
Thermal Mass Flow Meter for Gases measuring monitoring analysing Direct mass flow rate measurement of gases Measuring accuracy: ±1.0% f.s. +0.5% m.v. pmax PN 16, tmax 175 C Fast response time No moving
More informationV-Cone Flowmeter DATASHEET
V-Cone Flowmeter ATASHEET JUNHO 013 IntraCone Cone Flow Meter Type: ICM etail: Cone-Element Technical Information 05/011 FLOW THE SPECIALIST IN LEVEL AN FLOW Cone Flow Meter Technical Information Intra-Automation
More informationIBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationIBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationCHAPTER (13) FLOW MEASUREMENTS
CHAPTER (13) FLOW MEASUREMENTS 09/12/2010 Dr. Munzer Ebaid 1 Instruments for the Measurements of Flow Rate 1. Direct Methods: Volume or weight measurements. 2. Indirect Methods: Venturi meters, Orifices
More informationEFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS
EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS DCN 364017 Rev 1 #
More informationCartridge Valves Technical Information. Quick reference
Quick reference Contents CPF0... 8. CP600-5... 8. CP60-5... 8. 066 handle kit... 8.5 MP06... 8.6 MP... 8.6 X05-FD0 Traction manifold... 8.9 X05-FD6 Traction manifold... 8.0 X05-FD0 Traction manifold...
More information473 Dew Point Hygrometer
High Performance Chilled Mirror Hygrometer With Cable Mounted Measuring Heads Highly precise chilled mirror dew point technology Cable mounted dew point and temperature measurement Aspirated and direct
More informationGeneral Specifications
General Specifications Model EJB110 Differential Pressure Transmitter [Style: S2] The model EJB110 Differential Pressure Transmitter can be used to measure liquid, gas, or steam flow,
More informationElectromagnetic Flowmeter FXE4000
ata Sheet ield IT Electromagnetic lowmeter XE000 The Electromagnetic lowmeter (EM) can be used to accurately measure the flowrate of liquids which have an electrical conductivity greater than µs/cm (0
More informationPressure Transmitter ED 701
Pressure Transmitter ED 701 Hygienic and industrial process connections Zero setting function Accuracy < 0.1% FS Quick response time < 25 ms High long-term stability Excellent repeatability Active compensation
More information